}

Tender For Beautification Work Of Hanuman Temple Of Sakhi Situated In Jhansi District, Excavation In Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling Watering And Ramming Of Excava, jhansi-Uttar Pradesh

Uttar Pradesh Tourism Development Corporation has published Tender For Beautification Work Of Hanuman Temple Of Sakhi Situated In Jhansi District, Excavation In Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling Watering And Ramming Of Excava. Submission Date for this Tender is 27-06-2024. Building Work Tenders in jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43829835
Tender For Beautification Work Of Hanuman Temple Of Sakhi Situated In Jhansi District, Excavation In Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling Watering And Ramming Of Excava
Open Tender
Indian
Uttar Pradesh
Jhansi
27-06-2024

Tender Details

Tender For Beautification Work Of Hanuman Temple Of Sakhi Situated In Jhansi District, Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur- plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. Supplying and stacking of good earth at site. Providing and laying cement concrete 14:8 (1) cement :4 coarse sand 18 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & Pric required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms, from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete, (plinth area of the building at ground floor only shall be measured as per 15.6313 (Partil 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows: (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters/sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering. shuttering finishing andreinforcement 1:1.5.3 (1 cement: 15 coarse sand (zone-III) derived from naturalsources: 3 graded stone aggregate 20 mun nominal size derived from natural sources) Upto plinth level (i) R.C.C. work in Footing (ii) R.C.C. work in Beam (iii) R.C.C. work in Columns Above plinth to floor-V Ivi Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.53 (1 cement: 1.5 coarse sand (zone-III) derived from naturalsources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) (iii) R.C.C. work in Columns (i) R.C.C. work in Lintel (ii) R.C.C. work in Beam (iv) R.C.C. work in Slab Centering and shuttering including strutting propping etc. and removal of form for all heights: Foundations, footings, bases of columns, etc. for mass concrete. Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick Columns, Pillars, Piers, Abutments, Posts and Struts. Edges of slabs and breaks in floors and walls Under 20 cm wide. M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 125 mm nominal size). Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. Same as in item No. 11 above but in super- structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement: coarse sand) Ground Floor Same as in item no. 14 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work, Ground Floor Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 or more. Ground Floor 15mm thick plaster with cement mortar in proportion of 14 cement & coarse sand of 2.25 F.M. 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement 6 coarse sand Ground Floor 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1) cement: 6 coarse sand. Ground Floor 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. Ground Floor Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms. vanitycounters, window sills, facias and similar locations of required size. approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Ground Floor Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 14 (1 cement: 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Ground Floor Providing and laying 6 to 8 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Cement concrete flooring 1:2:4 (1 cement 2 coarse sand 4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25) mm thick floor) Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 4 (1 cement: 25 mm thick Ground Floor Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Ground Floor Supply and fixing 6 mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tiles upto 300x300mm). Ground Floor Providing and fixing ISI marked flush door shutters conforming to IS 2202 (Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick Single leaf 35 mm thick Double leaf Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing Fabrication of hold fast for door, chaukhats and windows. Providing & fixing of door / windows grill. 7-Section steel windows with Openable panels. excluding Glass panes. Angle iron square (40x40x5). Fixing of Door, windows / ventilators chaukhats in position. (a) Door chaukhats (b) Window chaukhats (c) Ventilator chaukhats Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3 apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matter sand papering and stoping including cost of all materials, labour, t && p etc. required for proper completion of the work. Same as item above but on new wood surface. Finishing walls with Acrylic smooth exterior paint of required shade: New work (Two or more coat applied 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied 2.20 kg/10 Sqm. Ground Floor Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade Two or more coats on new work (For Internal ceiling surface) Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Ground Floor Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick hats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to 15: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 15 (1 cement 15 coarse sand) admixed with water proofing compound conforming to 15: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes Providing & fixing stainless steel sliding door bolts ISI marked complete. (a) 300mm x 16mm Providing & fixing stainless steel tower bolts IS1 marked complete. (a) 250 mm x 10mm (b) 200 mm x 10mm Providing and fixing bright/matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 14 (1 cement: 4 coarse sand).Ordinary cement without any pigment Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)., providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm (3/4x3/8x1/12) and braced with flat form diagonals 20x5mm (3/4x3/16) size with top and bottom rails or T-iron 40x40xfimm (15x1x14) with 38 mm dia steel pullys with bolts, nuts locking arrangement, stoppers handles complete including applying a priming coat of approved lead paint. STATUEOF SHRI HANUMAN JI MADE BY CEMENT/MARBEL DUST ELECTRIFICATION WORKS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 15 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 25 sq. mm earth wire 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A Switch 2 way 5/6 A switch 15/16 A Switch 3 pin 5/6 A Socket outlet Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) 3 Module 100mmX75mm) 4 Module 125mmX75mm) 16 Module 200mmX75mm) 8 Module 125mmX125mm) 12 Module 200mmX150mm) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. Installation Testing, Commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5. sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mmsweep Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted. including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door Supplying and fixing 5 A to 32 A rating. 240/415 V, 10 KA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe et Earthing with G.1. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 27 metre long etc. (but without charcoal/ coke and salt) as Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.1. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.1. nut bolt & spring washer spaced at 50mm) S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGMS. sheet incorporating 10mm dia, M.S round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & Petc., for proper completion of work. Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete, excluding tube on surface complete in all respect 1 X 22 W Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete FIRE FIGHTING SYSTEM Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity(ISI Marked 15:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD- 2018 Supply & fixing of CO2 type fire extinguisher, 45 kg. capacity(ISI Marked 15:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD- 2018 PLUMBING WORKS Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Providing and fixing white vitreous china. pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. Providing and fixing wash basin with CI. brackets, 15 mm CP. brass pillar taps, 32 mm CP. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 630x 450 mm with a pair of 15 mm C.P. brass pillar tap. Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in CP. brass) with waste fitting as per 15:2556, CL trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C automatic flushing cistern Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (Icement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. Providing & fixing PIMI towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. Providing and fixing PIMT Liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. a) 110mm diameter Supply and fixing of UPVC S.W.R. pipe type-B confirming to 15-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other flttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&l Required for proper completion of work. 110 mm O.D. Supply and fixing of UPVC SW.R. pipe nahni trap size 100x75,110/90 mm confirming to IS- 14735 self cleaning design fixed in PCC 1:24 and supply and fixing of 125 mm dia heavy duty CP brass jali. Supply and fixing of UPVC S.W.R. plain bend confirming to 15-14735. Size 110 mm Supply and fixing of UPVC S.W.R. plain tee confirming to 15-14735. Size 110x110x110 mm Supply and fixing of UPVC S.W.R. plain Y confirming to 15-14735. Size 110 mm Laying cement concrete 1:5:10 in haunching P.V.C./ S.W. Pipes including conccrete for bedding necessary form work and curing complete.around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring/ground) 110 mm diameter Making khurras 45x45 cm with average mininum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet Im x 1 mx 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, punning, rounding the edges and making and finishing the outlet complete. a) 110mm Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with MS. screws of required length including cutting brick work and fixing in cement mortar 14 (1 cement: 4 coarse sand) and making good the wall etc. complete. a) 110mm Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20mm dia nominal outer dia pipes 25mm dia nominal outer dia pipes 32mm dia nominal outer dia pipes Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes 20mm dia nominal outer dia pipes 25mm dia nominal outer dia pipes 32mm dia nominal outer dia pipes Providing & fixing CP brass bib cock of approved quality conforming to 15 8931 15mm nominal bore Providing & fixing C.P. brass long body bib cock of approved quality conforming to 15 standards and weighing not less than 690 gms. 15mm nominal bore Providing and fixing gun metal gate valve with wheel of approved quality(screwed end) 25mm dia nominal bore Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore Supply and hoisting of Sintex or equivalent high density polyethylene seemless of piece moulded tanks and placing the same in proper position including all taxes, labour and Täck etc. for proper completion of work. Tnak should be ISI marked, Sintex or equivalent. For 500 litres Providing and fixing gun metal gate valve with wheel of approved quality. a) 20 mm dia nominal bore Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides. ramming of bottoms, depth upto 15 m including getting out the excavated soil && then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc && disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. Providing, laying and joining, PVC/swr pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete a) 110mm diameter Laying cement concrete 1:2:4 in haunching P.V.C./ S.W.R Pipes including conccrete for bedding necessary form work and curing complete. a) 110mm dia Providing and frxing 5.W. Gully trap grade A complete with C.L. grating brick masonry chamber and water tight C.Lcover frame of 300 x 300mm, size (inside) square mouth traps of P or S type traps. a) 100 x 150 mm. dia. Constructing brick masonry manhole in cement mortar 1:4 (1 cement 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement 2 coarse sand 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement 4 coarse sand & graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement 3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1) cement 2 coarse sand 4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 900x800mm and 500mm deep including Cl cover with frame With FPS bricks of class designation 75 Extra for depth of man hole size 900x800mm Inside size 900x1200 mmm & 1.0 meter deep including CL. cover with frame Replacement of M.S. foot rests including dismantiling concrete blocks and fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar Supply and fixing of UPVC S.W.R. pipe type-B confirming to 15-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to 15-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other flittlings such as elbow.bend,tee and y-tee including supply of al marerial labour and T&P Required for proper completion of work 110 mm O.D. Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS- 14735 self cleaning design fixed in PCC 1:24 and supply and fixing of 125 mm dia heavy duty CP brass jali. EXTERNAL, PLUMBING WORKS Constructing brick masonry manhole in cement mortar 1:4 (1 cement 4 coarse sand) RCC top slab with 1-2-4 mix (1 cement 2 coarse sand 4 graded stone aggregate 20mm nominal size), foundation concrete 1:48 mix (1 cement:4 coarse sand 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement 3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1) cement :2 coarse sand 4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 900x800mm and 450mm deep including CI cover with frame (light duty) 455x610 mm intermal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg): With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Extra for depth of man hole size 900x800mm Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar (I cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: For pipes 100 to 250 mm diameter Providing and laying cement concrete 1:5:10 (1) cement: 5 coarse sand 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100 mm diameter S.W. pipe 150 mm diameter S.W. pipe Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement trenches,refiling and testing of joints complete as per direction of e/ i external work 32mm nominal bore. 40mm nominal bore. Providing and fixing gate valve with Cl wheel of approved quility (screwed end): 32mm 40mm Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common bunt clay FPS.(non modular) bricks of class designation 7.5 Hanching of CPVC pipe with PCC 1:2:4 (1) cement: 2 coarse sand: 4 stone grit) of cross section 200 x 200 mm concrete Making connection of G.1. distribution branch with G1. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40 mm dia nominal bore LANDSCAPING WORK Supplying and stacking sludge at site including royalty and carriage up to 5 km (sludge measured in stacks will be reduced by 8% for payment). Carrigae of sludge upto 5 K.M. Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment): Screened through sieve of 15. designation 4.75 mm Carrigae of manure upto 5 K.M. Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately). Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20%: 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of marnure, sludge or extra good earth if needed to be paid for separately). Holes 0.9 m dia. and 0.90 m deep. Plantation of trees Supply and stacking of Azadirachta indica (Neem) plant of height 120-130 cm. in big polybag of size 25 cm as per direction of the officer in charge. Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big polybag of size 25 cm as per direction of the officer-in-charge. Supply and stacking of Ficus religiosa (Peepal) plant of height 150-165 cm. in big polybag of size 30 cm as per direction of the officer in charge Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. Providing and fixing M.S. flat iron tree guard 60 em dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick MS. sheet of size 250x100 mm shall be welded to the treeguard near the middle height and lettered CPWD/PWD/any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge SEPTIC TANK WITH SOAK PIT Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth In all kind of soil upto 1.5m to 3.0m. depth In all kind of soil upto 3.0m to 4.50m. depth Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement: 2 coarse sand: 4 gradded stone aggregae 20 mm nominal size) Reinforced cement concrete work in slab with 1:1.5:3 (1 cement: 15 course sand: 3 graded stone aggregate 20mm normal size). Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1) cement: 4 coarse sand) Reinforcement for R.C.C work including, straightening, cutting bending binding and placing in position complete. qty same as ITEM NO.3 Centring and shuttering including struting proping etc and removal of form for slab. 15mm cement plaster on rough side of mix 1:4 (1) cement: 4 course sand) 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4(1 cement: 2 coarse sand: 4 gradeed stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1-2(1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed 2 litre per 50 kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. Providing and fixing CL tee at the inlet and outlet of septic tank. Providing & fixing 75mm dia vent pipes. Providing & fixing of 75mm dia cast iron terminal guard. Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M12 -10- Circular shape 500mm internal diameter LD. 2.5- Circular shape 450mm internal diameter Making soak pit 25 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and 5.W. drain pipe 100 mm diameter, 1.5m long complete as per standard design. With F.P.S. bricks COST OF BORING External w/s arrangments with T.W. boring 150 mm dia with 110 mm dia PVC pipe assembly, 2.00 HP. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements etc. 110 MM PVC casing pipe of ISI mark slotted. 110 MM PVC casing pipe of ISI mark plain. P/F 50mm GI pipe (B) class. (DSR 18.12.6) Nylon mesh for filter. Plastic dori. Solvent cement. 110 mm End cap. 110 mm Submersible cap. 50 mm MS clamp (Heavy) 50 mm GI elbow 50mm x 110 mm Gl nipple 2 HP submersible pump of ISI mark with automatic panel 10 sqm. W core submersible cable. Drilling charges for 6 tubewell Pea Gravel 2 MS socket Cartage of material upto site. (15) INTERLOCKING Earth work in exacavation in t. in ordinary soil(loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in alead of 50m Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form work, in foundation and floors Class M-150 brick work in 1:4 cement coarse sand (of 2.5 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. Interlocking Tiles-Rubber moulded refiective Zig-Zag 80mm Providing and laying of Interlocking Concrete Block Laying of Pavements having thickness 80mm including levelling and dressing of surface to required level and slope, spreading and moisting 30m thick local sand on bend, filling joints with local sand on bend, filling joints with local sand etc for proper completion of the work as per drawing and technical specification clause 1504 COST OF DESIGNER SITTING BENCH COST OF RED SAND STONE DUSTBIN & BUCKET

Key Value

Document Fees
INR 2714 /-
EMD
INR 623000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail