}

Tender For Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P.), 1 Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P, sitapur-Uttar Pradesh

Government Departments has published Tender For Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P.), 1 Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P. Submission Date for this Tender is 06-07-2024. Building Work Tenders in sitapur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43800755
Corrigendum : Tender For Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P.), 1 Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P
Open Tender
Indian
Uttar Pradesh
Sitapur
06-07-2024

Tender Details

Tender For Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P.), 1 Construction of Chakrateertha Kund Complex and Other Truism Development work at Naimisharanaya, District- Sitapur (U.P.) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil l (1.5m to 3.0m) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 6 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 7 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 10 Centring and shuttering including strutting,propping etc. and removal of form for 11 Foundations, footings, bases of columns etc. for mass concrete. 12 Suspended floors, roots, landings, balcnies and access platform. 13 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 14 Columns,Pillars, Piers, Abutments, Posts and Struts 15 Stairs,(excluding landings) except spiral-staircaces. 16 Weather shade,Chajjas, corbels etc. including edges 17 Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of deshutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roots, laning, beams and balconies (Plan area to be measured) 18 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement contant of 330 kg/cum All works upto plinth level 20 Concrete of M25 grade with minimum cement content of 330 kg /cum 21 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap 22 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap 23 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap 24 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 26 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 27 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 28 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red 29 Area of slab upto 0.50 sqm 30 Area of Slab over 0.50sqm 31 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. 32 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 33 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 34 Providing and fixing 12 mm toughened glass partition with neccessary fittings and Applying clear silicon on joints complete in all respect. 35 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 36 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edge 37 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square. 38 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 39 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 40 Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain)toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor = 0.45, U-Value = (W/sq.m-K) 5.7W /M2K, Visible light transmittance = 0.30) 41 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 42 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortice lock with key cylinder fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 43 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 44 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 45 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 46 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 47 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.. 48 Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 49 Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 50 Providing and fixing approved brand and manufacture SS 304 grade Center Patch Lock wih Cylinder complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 51 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness 52 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 53 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube 54 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 55 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 10 mm 56 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backingfilled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : White sand stone - exposed face fine dressed with rough backing 30 mm thick 57 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 58 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases 59 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 60 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 61 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm 62 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 63 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 600x600 mm 64 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 65 Providing and laying 18 mm thick leather finish steel grey granite stone flooring in required design and patterns, in linear as well as curvilinear portions in building flooring, footpath etc. all complete as per the architectural drawings with over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 66 Providing and fixing machine cut, mirror/ eggshell 18mm thick leather finish steel grey granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 67 Applying breathable, non-reactive,antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 68 Supply, fabricating, transporting, hoisting and fixing in position good quality durable Mirzapur sand stone/ any other type of sand stone in various elements for all level all height.Stone shall be free from cracks, lines, stains, white spots of efflorescence and even in shade for each elements. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with differant process ofi.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The drawings provided are vary preliminary and amount of carving will be more then what is shown on the drawings. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 69 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. White sand stone 70 Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. 71 Providing and fixing 40mm thick cladding comprising of Wooden framework using 25mx50mm sections at a maximum spacing of 600mm in any one direction (including adding members as required) covered with12mm thick BWP ply layered with 4mm thk. veneer on one sidepasted and pressed with adhesive to give a uniform and smooth finish, including4mm thk. S.S. strip framework on all sides of veneer panels with wooden member surround, top moldings / margins, melamine polish etc. to finish the thickness, as shown complete in drawing. All members / ply etc. shall be treated with anti-termite solution as per norms. No extra shall be paid for making of openings, door / window frames and for making provisions for electric conduits. etc. all complete as per direction of Engineer-in-charge. 72 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 73 Providing and fixing Granite stone gang saw cut (polished and machine cut) of thickness 18mm for wall lining, backing filled with a grout of average 12mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar with an admixture of pigment to match the granite shadeetc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 74 12mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) 75 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand) 76 6 mm cement plaster to ceiling of mix : 1:3(1 cement: 3 coarse sand) 77 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 78 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 79 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 80 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 81 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or more coats on new work 82 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 83 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 84 Two or more coats on new work 85 Melamine polishing on wood work (one or more coat) 86 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 87 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) 88 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 89 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron) 90 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminum (minimum thickness of powder coating 50 micron) 91 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 10 mm depth and 10 mm width 92 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 93 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm 94 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 95 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 96 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. without disturbing the other structural elements. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 97 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. without disturbing the other structural elements such as column, beams & slab. 98 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 99 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 100 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 101 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 102 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 103 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 104 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 105 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 106 Supplying and stacking at site dump manure screening by 4.75 mm sievefrom approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : 107 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep 108 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 109 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 110 Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 111 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPEbag as per direction of the officer-in-charge. 112 Providing and displaying of Dracaena margineta plant, having ht. 30 cm to 45 cm with colorful leaves, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 113 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e lawn trees,shrubs, hedge, flower beds,foliages,creepers etc including hoeing, weeding pruning replacement of plants, gap filling, watering,mowing of lawn,grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecting sites,pesticide and fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office in charge. (cost of good earth,menure, fertilizers, insecticide , pesticide,lawn mover and brush cutter with fuel will be provided by the department and other T/P material/articles shall be provided by the contractor. Open spaces (1Mali for 3.00 Acre). 114 Providing and fixing watercloset squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, including wall hung cistern & installation kit with duel flush fitting (2.0/4.0 lts. per flushing), conforming to IS 7231, with all fittings & fixtures complete including cutting and making good the walls and floors wherever required.( MAKE-1 : JAQUAR, MODEL NO. INDIAN WC : ECS-WHT-453LE & CISTERN : WHC-WHT-184BTTG OREQUIVALENT.) White vitreous china Orissa pattern WC pan of size 415 x 515 x 255mm . 115 Providing and fixing white vitreouschina extended wall mountedwater closet of size 350 X 545 X 380mm of approved shape including providing and fixingof concealed cistern with duel flush fitting (2.0/4.0 lts. per flushing), including sheet cover, and cistern fittings, nut bolt gasket,chair etc complete. ( MAKE-1: JAQUAR, MODEL NO. WALL MOUNTED WC : FLS-WHT-5953 & CISTERN & FACE PLATE :JCS-WHT-2400SG & JCP-CHR-152415 OREQUIVALENT.) 116 Providing and fixing white vitreous china flat back half stall urinal of size 370 x 315 x 620mm with urinal valve auto closing system (0.75 lts. per flushing) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :. ( MAKE-1: JAQUAR, MODEL NO. URINAL : URS-WHT-132530 & URINAL VALVE AUTO CLOSING :PRS-CHR-077G OREQUIVALENT.) 117 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with15 mm C.P. brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & BASIN MIXER :FLR-CHR-5001BG & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15mm CP Brass single hole basin mixer with flow rate 2.5 litre per minute at 3 bar . 118 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever requiredKitchen sink with drain board 119 510x1040 mm bowl depth 250 mm 120 Providing and fixing hand shower (Health faucet)with 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor withflow rate 6 litre per minute at 3 bar in chrome finish and wall hook. ( MAKE-1: JAQUAR, MODEL NO. HEALTH FAUCET : ALD-CHR-573GA OREQUIVALENT.) 121 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ( MAKE-1: JAQUAR, MODEL NO. BOTTLE TRAP : ALD-CHR-769L300X190 OREQUIVALENT.) 122 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. For physically handicap person consisting of; 123 Wall mounted WC Pan-01 no. withbuilt in Jet of Cera CAT no.S1046105 124 Concealed Cistern Cistern-01 no.of Cera CAT no. B1110108 & Knob B1120118 125 Soft Close Seat Cover -01 no of Cera CAT no.B1520106 126 Wall hung Wash Basin -01 no of Cera CAT no.S2040147 127 Spatula Single leverCera CAT no F9030451 128 Wall mounted Grab bar 600 mm long - 2 nos of Cera CAT no.B2210106 129 Wall mounted Hinged hand rail 750 x 100-01 no Cera CAT no B2210108 130 Bottle Trap Cera CAT no F8060403 131 Waste Coupling Cera CAT no F8050101 132 Stainless soap dish Cera CAT no F5007106 133 Tissue paper holder Cera CAT no F5007110 134 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete40mm Dia 135 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 136 Providing & fixing toilet paper holder C.P. brass 137 Providing and fixingof fully automatic NO TOUCH durable & shock proof hand drier of approved make & manufacture suitable to operate on 220 volts, single phase 50 hz, A.C. power supply, 1500 Wattand directly plugged to power point complete in ABS plastic body having drying time 20-30 seconds complete as per direction of Engineer in Charge. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. 138 Providing, Fixing of CP brass Towel Rack 600mm long without hanger with 3 hooks and CP brass screws complete as required. 139 Providing & fixing glass urinal partition of Height: 900mm,Width: 450mm &Frosted Safety Glass: 8 mm with fixed with expandable anchor fasteners with C.P. brass bolts and washers, embedded in wall with anchor and set in cement concrete complete including cutting and making good the walls wherever required. 140 Providing and fixing soil waste and vent pipesHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 75 mm dia. 141 Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. 142 For 100mm dia pipe 143 Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete 144 100 mm dia 145 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 146 75 mm dia 147 Providing and fixing plain bend of required degree: 148 100 mm dia 149 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 150 75 mm dia 151 100 mm 152 SS 304 grade coupling with EPDM rubber gasket 153 75 mm 154 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipe of diameter: 155 100mm 156 Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 157 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. 158 Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) 159 Total bracket length 810 mm of approved shape and design (for two 100 mm dia pipes) 160 Providing & fixing Nickel Chromium Platedliquid soap container/ dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. ( MAKE-1 : JAQUAR, MODEL NO. - ACN-CHR-1137N OR EQUIVALENT. 161 Providing, Fixing of CP brass Towel Ring with CP brass wall brackets and providing & fixing CP brass screws complete as required. ( MAKE-1: JAQUAR, MODEL NO. TOWEL RING : ACN-CHR-1121N OREQUIVALENT.) 162 Providing & fixing soap dish holder of approved design.( MAKE-1: JAQUAR, MODEL NO. SOAP DISH : ACN-CHR-1131N OREQUIVALENT.) 163 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with 15 mm C.P. brass pillar tap of auto closing type of approved quality and make with, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & PILLAR TAP :PRS-031G & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) 164 White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15 mm C.P. brass pillar tap auto closing type of approved make with flow rate 2.5 litre per minute at 3 bar . 165 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. ( MAKE-1: JAQUAR, MODEL NO. SINK MIXER : FLR-CHR-5163GD OREQUIVALENT.) 166 Providing , Fixing of CP Brass Shower Mixer with provision of overhead shower with 115mm long bend pipe, in built spout, spout/shower selector with flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. ( MAKE-1: JAQUAR, MODEL NO. SHOWER MIXER : FLR-CHR-5273UPRGD OREQUIVALENT.) 167 Providing,Fixing wall mounted Double Coat hookon door complete. ( MAKE-1: JAQUAR, MODEL NO. COAT HOOK : AKP-CHR-35761P OREQUIVALENT.) 168 Providing & fixing wall mounted 300mm Long SS Grab Bar including cutting & making good the walls. ( MAKE-1: JAQUAR, MODEL NO. GRAB BAR : AKP-CHR-35701PS OREQUIVALENT.) 169 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. ( MAKE-1: JAQUAR, MODEL NO. 2 WAY BIB COCK : FLR-CHR-5041NG OREQUIVALENT.) 170 Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector. 171 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required. (MAKE-ModiGuard Sparkle Mirror ) 172 Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe. 173 Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect.100 mm dia 174 Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes andsockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge. 175 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge.Circular Type 125 mm nominal dia with 25 mm waste hole 176 Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 177 Capacity 15 litres size 448X448X345mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : ELENA OREQUIVALENT.) 178 Capacity 35 litres size 875X400mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : VERSA HORIZONTAL MANUAL OREQUIVALENT.) 179 Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC Plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and spcified (In Terrace & Shaft- Hot Water Supply) 180 (Note: Ball Valve and union will be charged extra and does not comes under Accessories) In internal Wall - Exposed on Wall 181 20 mm OD 182 25 mm OD 183 32mm OD 184 40 mm OD 185 Providing and fixing GI pipes(IS:1239 Heavy Class) complete with GI fittings and clamps, i/c cutting and making good the walls etc.(In Terrace & Shaft- Cold & Flushing Water Supply) 186 Internal work - Exposed on Wall 187 25 mm nominal bore 188 32 mm nominal bore 189 50 mm nominal bore 190 Providing and fixing G.I. pipes(IS:1239 Heavy Class) complete with G.I. fittings including trenching and refilling etc.(For External Riser Pipe) 191 External Work 192 25mm nominalnominal bore 193 32mm nominalnominal bore 194 40mm nominalnominal bore 195 50mm nominalnominal bore 196 65 mm nominal nominal bore 197 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 198 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 199 25mm nominal bore 200 32mm nominal bore 201 50mm nominal bore 202 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 203 20 mm nominal bore 204 25mm nominal bore 205 Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with brass unions : 45 cm length 206 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 207 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 208 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 209 25mm diameter pipe 210 32mm diameter pipe 211 50mm diameter pipe 212 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 213 25mm diameter pipe 214 32mm diameter pipe 215 40mm diameter pipe 216 50mm diameter pipe 217 65mm diameter pipe 218 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 219 25mm diameter pipe 220 32mm diameter pipe 221 40mm diameter pipe 222 50 mm diameter pipe 223 65 mm diameter pipe 224 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 225 15 mm nominal bore 226 20 mm nominal bore 227 25 mm nominal bore 228 32 mm nominal bore 229 40 mm nominal bore 230 50 mm nominal bore 231 65 mm nominal bore 232 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 233 Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS:8931 with flow rate 2.5 litre per minute at 3 bar: (MAKE-1: JAQUAR, MODEL NO. SHORT BODY BIB COCK : FLR-CHR-5037NG OREQUIVALENT.) 15mm nominal bore 234 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms with flow rate 2.5 litre per minute at 3 bar. (MAKE-1: JAQUAR, MODEL NO. LONG BODY BIB COCK : FLR-CHR-5047NG OREQUIVALENT.) 15mm nominal bore 235 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. (MAKE-1: JAQUAR, MODEL NO. ANGLE VALVE : AQT-CHR-3057 OREQUIVALENT.) 236 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 237 50 mm dia 238 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 239 Internal work - Exposed on Wall 240 65 mm diameter pipe 241 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. 242 65 mm diameter pipe 243 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore 244 65mm dia. 245 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 246 65mm dia. 247 Providing, laying and joining in position HDPE pipes with slipon flange, High density Poly Ethylene pipe and conforming to I.S. 4984-1995 of required grade / class, 16kg/sq.cm pressure and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. 248 110 mm dia. (OD) (16.0 kgf/sq cm.) 249 160 mm dia. (OD) (16.0 kgf/sq cm.) 250 Providing and fixing motorised butterfly valve with Control Panel & Float Type Magnetic Level Sensors suitable for 220-230 volts AC to operate valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box (upto 6 mt qty approx.) etc., complete. 32 mm dia 251 Supply installation, testing and commissioning of self-contained Drinking water cooler with inbuilt RO confirming to IS: 1475 with amendment no. 1 to 7, suitable for operation on 230 volts ± 10%, 50 Hz, single phase A.C. supply. The two tank inbuilt (hot & cold) and body casing of the water cooler shall be made out of stainless steel. The water cooler will be of following capacities with two numbers faucets / stop cocks (1 no Normal water & 1 no of hot water): Nominal Storage Capacity - 40 Ltrs. Hot water Storage Capacity - 40 Ltrs. 252 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 253 200 mm diameter S.W. pipe 254 250 mm diameter S.W. pipe 255 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 256 200 mm diameter S.W. pipe / RCC pipe 257 250 mm diameter S.W. pipe / RCC pipe 258 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 259 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 260 300mm dia RCC pipe 261 450mm dia RCC pipe 262 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 263 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 264 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 265 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 Extra for depth for manholes: Size 90 x 80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 268 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 269 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 350 to 450 mm diameter 270 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 271 Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 272 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 273 Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 274 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 275 Ordinary Rock 276 Hard Rock(requiring blasting) 277 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 278 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). 279 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia. 280 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia. 281 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. 282 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 283 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 284 Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 285 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 286 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 287 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified. 80 mm dia. 288 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 289 80 mm dia. 290 Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings. 291 Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase. 292 Providing & fixing cable 6 sq.mm. From submersible pump to panel board. 293 Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet. 294 Earth work in excavation by mechanical means (Hydraulicexcavator) / manualmeansoverareas(exceeding30cmindepth.1.5minwidthas well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 295 All kinds of soil 296 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 297 Extraforeveryadditionalliftof1.5morpartthereofinexcavation /banking excavated or stacked materials. 298 All kinds of soil 299 Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shttering - All work up to plinth level 300 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate40mm nominal size) 301 Centering & shuttering including strutting, propping etc. and removal ofform work for: 302 Foundations, footings, bases of columns etc. for mass concrete. 303 Lintels, beams, plinth beams, girders, bressumers and cantilevers 304 Suspended floors, roofs, landings, balconies and access platform. 305 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 306 SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete upto plinth level. 307 Thermo-Mechanically Treated bars. 308 Providingandlayinginpositionmachinebatchedandmachinemixed design mix M-25 grade cement concrete for reinforced cement concrete work,usingcementcontentasperapproveddesignmix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishingandreinforcement,includingadmixturesin recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,improveworkabilitywithoutimpairingstrengthanddurability as per direction of Engineer-in-charge. 309 All works upto plinth level 310 6mmcementplaster1:3(1cement:3finesand)onceiling/R.C.C. Beams etc. 311 Neat cement punning. 312 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 313 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 314 150 mm dia. R.C.C. pipe 315 Providing and fixing soil, waste and vent pipes 316 100 mm dia 317 Sand cast iron S&S pipe as per IS: 1729 318 Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989 319 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786,havingminimumcrosssectionas23mmx25mmandoverall minimum length 263 mm and width as 165 mm with minimum 112 mm spacebetweenprotrudedlegshaving2mmtreadontopsurfaceby ribbing or chequering besides necessary and adequate anchoring projectionsontaillengthon138mmasperstandarddrawingand suitabletowithstandthebendtestandchemicalresistancetestasper specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cmcementconcreteblock1:3:6(1cement:3coarsesand:6graded stone aggregate 20 mm nominal size) complete as per design. 320 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 321 Rectangular shape 600x450 mm internal dimensions 322 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 323 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 324 Constructingsoakpit1.20x1.20x1.20mfilledwithbrickbatsincluding S.W.drainpipe100mmdiameterand1.20mlongcompleteasper standard design. 325 Constructingbrickmasonrycircularmanhole1.22minternaldiaatbottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand)insidecementplaster12mmthickwithcementmortar1:3(1 cement:3coarsesand)finishedwithafloatingcoatofneatcement foundationconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 40 mm nominal size) and making necessary channel in cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)finishedwithafloatingcoatofneatcement,all complete as per standard design : 326 1.68mdeepwithSFRCCoverandframe(heavydutyHD-20gradedesignation)560mminternaldiameterconformingtoI.S.12592,total weightofcoverandframetobenot lessthan 182kg. fixedin cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)includingcentering,shutteringallcomplete. (Excavation,footrestsand12mmthickcementplasterattheexternal surface shall be paid for separately) : 327 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 328 Extradepthforcirculartypemanhole1.22minternaldia(atbottom)beyond 1.68 m to 2.29 m : 329 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 330 Excavatingtrenchesofrequiredwidthforpipes,cable,etc including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soilasrequired,inlayersnotexceeding20cmindepthincluding consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 331 All kinds of soil 332 Pipes cables etc. exceeding 80 mm dia. But not exceeding 300mm dia. 333 Providing, layingandjointingglazed stone warepipes grade class SP-1with stiffmixtureofcementmortarin theproportionof1:1 (1cement :1 fine sand) including testing of joints etc complete. 150 mm diameter 334 Providingandlayingcementconcrete 1 : 5 : 10 (1 cement : 5 coarsesand : 10 gradded stoneaggregate40 mm nominal size) alround S.W. Pipesincludingbed concrete as per standard design. 150 mm diameter S.W.Pipe 335 Earthwork in excavation by mechanical means ( Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, with in a lead of 50m. All kind of soil 336 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials 337 All kinds of soil 338 Qty for 1.5-3.0 M depth RWH & Desilt Chamber 339 Qty for 3.0-4.5 M depth RWH-Rate 2 Times 340 Qty for 4.5-5.75M depth-RWH -Rate-3 Times 341 Providingorange color safety foot rest of minimum 6mm thickplasticencapsulated as per IS : 10910 on12mm dia steelbar conformingto IS :1786 having minimum cross section as 23mm x 25mm and over allminimum length 263mm andwidth as 165mmwith minimum 112mm space between protrude legshaving2mm tread on top surface by ribbing or chequering besides necessary andadequate anchoring projections on tail length on 138mmas per standard drawing and suitable to with dtand the bendtest andchemical resistancetest as per specifications and havingmanufacturespermanent identification make to be visible even afterfixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 342 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 343 12 mm cement plaster finished with a floating coat of neat cement of mix : 344 1:3 (1 cement: 3 fine sand) 345 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 346 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 347 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 348 Cement mortar 1:6 (1 cement :6 coarse sand) 349 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 350 All types of soil 351 300 mm dia 352 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 353 200 mm nominal size dia 354 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 355 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 356 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 357 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 358 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge 359 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 360 Centering and shuttering including strutting, propping etc. and removal of form for 361 Suspended floors, roofs, landings, balconies and access platform 362 Edges of slabs and breaks in floors and walls 363 Under 20 cm wide 364 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 365 TMTsteel bars 366 Providing, fixing, commissioing, testing and of open well submersible pump for each pump IP 58 protected electric enclosure comprising of 2 Nos. Electrical Driven Horizontal pumps with all accessories coupled to motor suitable for operation on 200-240 volts, 1 phase 2900 RPM. motor with SS 304 body all accessories such as NRVs, valves, common delivery header complete in all repsects. Pumps shall be suitable for 200-240volts 1 phase 50 Hz A.C supply & shall be having the following specifications. Moc of pump -Impeller- CI, csing - CI , shaft- SS 410. Delivery header including all GI pipes, CI valves, CI NRV, bourden type Pressure gauge & accessories complete. 367 All accessories for running two pumps with dry running protection etc. 368 FOR DOMESTIC TRANSFER PUMP 369 No. ofPumps: 2 (1 Working + 1 Stand by ) 370 Capacity:120 LPM 371 Head :30m 372 FOR GARDEN IRRIGATION PUMP 373 No. ofPumps: 2 (1 Working + 1 Stand by ) 374 Capacity:140 LPM 375 Head :30m 376 Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connectedto TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect 377 SUBMERSIBLE UNDER GROUND FOR BOREWELL 378 No. ofPumps: 1 (1 Working ) 379 Capacity:160 LPM 380 Head :60 m 381 SUBMERSIBLE UNDER GROUND FOR BOREWELL 382 No. ofPumps: 1 (1 Working ) 383 Capacity:160 LPM 384 Head :60 m 385 Supply installation testing and commissioning of filtration plant for kund cap. 50cum/hr. including pumps, filters, piping , valves and pumps complete in all respect. 386 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metre depth below ground level. 387 All Types of Soil 388 300mm dia 389 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All Types of Soil 300mm dia 390 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 391 200 mm nominal size dia 392 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 393 200 mm nominal size dia 394 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 395 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 396 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 397 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 398 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 399 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch modular plate suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. 400 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 401 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 402 Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 403 Wiring for light plug points / power plug points with 4 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 404 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 405 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 406 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 407 2x10 sq. mm + 1x6 sq. mm earth wire 408 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 409 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 410 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 411 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. 412 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 413 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 414 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 415 Supplying and fixing brass batten/ angle holder including connection etc. as required. 416 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 417 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 418 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm 419 SITC of Input power : 20W LED, compact and minimilist surface mounted designed for ceiling & pendant mount. Beam angle 110°(Fixed). Luminaire made of extruded anodised aluminium (grade 6063) of high corrosion resistance, polycarbonate end caps and non corrosive stainless steel fasteners. Polycarbonate diffuser. Protection class IP20. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM = 3 MacAdam. K-Lite LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor>0.95, THD<10%, Surge protection 3KV. Luminaire dimension : 1200mm length x 43mm width x 52mm height. CE & BIS Certified. Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 420 SITC of Input power : 18W led, ceiling mounted compact downlight. Beam angle 15° / 25° / 40°. Luminaire made of extruded aluminium, pressure die-cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Gravity die cast aluminium plate for surface mounting on ceiling. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 100mm diameter x 150mm height. CE & BIS Certified. Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 421 Supply, installation, testing & commissioning of 595mm/600mm mm long surface mounting type LED fitting with diffuser having a lumen output not less than 1100 lumens, CCT 4000K and LED efficacy better than 110 lumen/ watt with opal diffuser in polycarbonate complete with CRCA / Pressure Die Cast Aluminium Housing and life of 50K burning hours (L 70) at 30 deg , THD =10%, CRI better than 80 with inbuilt protection against short circuit, over voltage protection and surge protection of up to 2 KV including connections etc. as reqd. 422 Supplying and fixing of 250 mm sweep Exhaust fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required. 423 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 424 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 425 6 way , Double door 426 12 way, Double door 427 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 428 8 Way (4+24), Double Door 429 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 430 For 6 way, Double door SPN MCBDB 431 For 14 way, Double door SPN MCBDB 432 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. 433 For 8 way, Double door TPN MCBDB 434 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 435 Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 436 25 Amp DP MCB 437 40 Amp DP MCB 438 Supplying and fixing of following rating, 240/415 volts, C curve, four pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amp FP MCB 439 Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 100 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 440 25 Amps 441 40 Amp 442 63 Amp 443 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 444 Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitablesize wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. 445 The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. 446 All Main Distribution board / Sub Distribution board / Meter boards which are located inside various blocks shall be partially Type Tested assemblies (PTTA) as per conforming to IEC-61439-1 447 The Moulded Case Circuit Breaker shall have a minimum fault breaking capacity (Ics) of not less than 35 KA & 25KA RMS for one second at 415 volts for MDB / SDB respectively. MCCB‘s above 63A should be provided with Copper & procader terminals. Incomer of Meter Board shall have a minimum short circuit breaking capacity (Ics) of 25KA for one second at 415volt. 448 ELECTRICAL PANEL 449 INCOMING 450 1 No. 125 Amp FP Moulded Case Circuit Breaker. 451 1 Set of phase indicating lamps with MCB. 452 1 Set of ON/OFF indicating lamps with MCB. 453 1 No. Digital MFM with CTs. 454 BUSBAR 455 150 Amp TPNaluminium busbar with coloured heat shrinkable sleeve. 456 OUTGOING 457 9 Nos. 40 / 63 Amp TPN Miniature Circuit Breaker. 458 3 Nos. 25 / 40 Amp DP Miniature Circuit Breaker. 459 Panel described as above 460 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 461 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 462 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 463 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 464 Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required. 465 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 466 Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum ConductorFRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. 467 3.5 core,50 sq.mm. 468 4 core,4 sq.mm. 469 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 470 Upto 35 sq. mm 471 Above 35 sq. mm and upto 95 sq. mm 472 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 473 3½ X 50 sq. mm (35mm) 474 4 X 10 sq. mm (25mm) (Also Used for 4 X 6 sq.mm) 475 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia 476 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness 477 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 478 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 479 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 480 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 481 Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 482 Extra for depth beyond 45 cm of brick masonry chamberFor 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 483 Extra for depth beyond 45 cm of brick masonry chamberFor 600x850 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 484 SITC ofIn-Ground 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Input power : 9W led DimensionØ173 x 220 mm Beam Angle : 40° (Tiltable 20°) Electronic driver ON/OFF CE and BIS, IP rating IP67 Die-Cast aluminium alloy housing (grade ADC12 with test certificate). 316 grade stainless steel front ring. Silicone seal gasket. SS fasteners. Mechanical resistance IK09. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. ABS plastic installation housing for preparing the recess opening in ground. The luminaire are fixed in recess installation housing by stainless steel screws. Clear toughened glass diffuser with controlled upward light emission. Lamp fixed position This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >80%, power factor >0.90, THD <15%, Surge protection 2KV.Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 485 SITC ofInput power : 18W,surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 160mm length x 100mm width x 154mm height. CE & BIS Certified. Inhouse NABL accredited lab Make :- K-Lite /Ligman/ Unilamp 486 SITC of Flexible LED Strip 3000K, 4000K, 6000K24Vdc CRI >80 MacAdam step 3 Input power : 12W led Dimension1000 x 12 mm Beam angle : 120° Electronic driver ON/OFF (External driver) CE and BIS, IP rating IP67. Copper coated flexible strip, Silicone moulded diffuser, End cap . Silicone moulded diffuser This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >10,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV.Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 487 FEEDER PILLAR(OUTDOOR TYPE) 488 Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust, vermin & weather proofFloor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thickCRCA sheet complete with followingequipments, includingdigital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CTs, internal wiring with suitablesize wires / cable, MS Angle stand for installation, RCC foundation, interconnection, painting complete as per specification & drawing. 489 INCOMING 490 1 No. 40 Amp FP Moulded Case Circuit Breaker. 491 1 No. 0 to 500 Volt digital voltmeter with inbuilt selector switch. 492 1 No. 40 Amp digital ammeter with inbuilt selector switch and CTs. 493 1 Set of phase indicating lamps with Single Pole MCB. 494 1 Set of ON / OFFindicating lamps with Single Pole MCB. 495 BUS BARS 496 100 Amp TPNaluminium busbar. 497 OUTGOING 498 1 Set 24 Hrs TSQ Timer 499 1 Set 40 Amp, TP Contactor & A/M switch and Push Button. 500 8 Nos. 20 Amp TP MCB, 10 KA breaking capacity. 501 Panel described as above 502 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 503 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fiat user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 504 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end. Approved Makes:Derwiser/Nexans/Siemon/Systimax 505 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 506 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 507 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 508 Supply, Installation, Testing & Commissioning of 15Uwall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Approved Makes: Derwiser/MTS/Rittal/APC/APW 509 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 510 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for camera at user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 511 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 512 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity. Approved Makes:Derwiser/Nexans/Siemon/Systimax 513 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 514 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 515 Supply, Installation, Testing & Commissioning of L2+ managed industrial PoE fiber switch with 24*10/100/1000M RJ45 ports and 4*1//10G SFP slot ports, Port 1-24 can support IEEE802.3af/at PoE.Switching capaticy of128Gbps, forwarding Rate 95.23 Mpps, having24 x 10/100/1000BASE-T PoE-plus(RJ45) with maximum PoE output power is 400W, 1 RS232 Console port.32K MAC address. Should have Static Routing ,system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP),and IPv6 features from day 1, Security Feature: Port Isolation, VLAN, MAC, Spanning tree, Multicast, DDM, ACL, QoS: 802.1p (COS), DSCP, SP, WRR, Classification based on source IP, destination IP, and port number etc.Approved Make :Cisco/ Impulse / Juniper / Nexxus 516 Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5 SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest.Approved Makes: HP / DELL / IBM / LENOVO 517 Supply, Installation, Testing & Commissioning of 8TB Surviellance Hard Disk. Approved Makes: WD /segate /Toshiba/HP 518 Supply, Installation, Testing and Commissioning of Full HD 55 LED Professional Display Panel.Approved Makes: Panasonic / LG/ Sony/ Samsung 519 Supply, Installation, Testing & Commissioning of Pure IP at core server Based voice solution with04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,28 IP users License ,01 Nos. IP Operator Console, 100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Should Support Redundant server in active-Active mode.Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 520 Supply, Installation, Testing & Commissioning of Type 1 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE .Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 521 Supply, Installation, Testing & Commissioning of 24 Port PoE Access Switches with switching capaticy of 300 Gbps, forwarding performance 240 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 720W and 4x 10G SFP+ uplink ports . Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address, 8K Multicast Routes, Should have static Routes from day 1.Approved make - Cisco / Juniper /Impulse / Nexxus/Arista 522 Supply, installation, testing and commissioning of 5 MP Bulletcamera ,ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS , 3.6 mm fixed lens , Quad stream support,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : Shutter speed :1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support up to 256GB, frame rate : Main stream should support 25 fps@5MP , Edge analytics : Customer Flow staistics,Cross Count Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , In built IR LED , IR Distance upto 30 meters , IP 66 , POE. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 523 Supply, installation, testing and commissioning of32 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out : 16chin / 4chout , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , 1x3.0 USBfor backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR .Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000,A.I maximum captured quantity200,000. UL,CE,FCC certified. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 524 GST Extra as applicable

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-07-2024 Date Date 06-07-2024

Key Value

Document Fees
INR 17700 /-
EMD
INR 3401000.0 /-
Tender Value
INR 17 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail