}

Tender For Construction Of Control Room, Boundary Wall And Other Misc. Civil Work At 33/11 K.V. S/S Bankat, Distt-Azamgarh., 1 Clearing Jungle Including Uprooting Of Rank Vegetations,Grass, Bush,Wood, Trees And Saplings Of Girth Upto 30Cm Measured At A , azamgarh-Uttar Pradesh

Government Departments has published Tender For Construction Of Control Room, Boundary Wall And Other Misc. Civil Work At 33/11 K.V. S/S Bankat, Distt-Azamgarh., 1 Clearing Jungle Including Uprooting Of Rank Vegetations,Grass, Bush,Wood, Trees And Saplings Of Girth Upto 30Cm Measured At A . Submission Date for this Tender is 10-07-2024. Building Work Tenders in azamgarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43639156
Corrigendum : Tender For Construction Of Control Room, Boundary Wall And Other Misc. Civil Work At 33/11 K.V. S/S Bankat, Distt-Azamgarh., 1 Clearing Jungle Including Uprooting Of Rank Vegetations,Grass, Bush,Wood, Trees And Saplings Of Girth Upto 30Cm Measured At A
Open Tender
Indian
Uttar Pradesh
Azamgarh
10-07-2024

Tender Details

Tender For Construction Of Control Room, Boundary Wall And Other Misc. Civil Work At 33/11 K.V. S/S Bankat, Distt-Azamgarh., 1 Clearing jungle including uprooting of rank vegetations,grass, bush,wood, trees and saplings of girth upto 30cm measured at a height of 1.0m above ground level and removal of rubbish upto a distance of 50m outside the periphery of UPPTCL area cleared. 2 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.5 meter (5ft) and lead upto 30 meter (100 ft.) and including filling, watering, and ramming of excavated earth into the trenches or into the space between the building and the side of the foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 Meters (100Ft.) from the foundation trenches. 3 Concrete with 4cm gaugestone ballast, coarse sandand cement in proportion of 12:6:1 in foundation & under floors including supply of all materials, labour & T&P etc. complete. 4 1st Class brickwork in 1:6 cement and coarse sand . mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. 5 Same as in item no. 4 above B.W. in 1:6 in super structures but for wall one brick (230mm) thick 6 Same as in item no. 4 above but B.W. in 1:4 in super structures but for wall up brick (115mm) thick 7 First class brick work in 1:4 cement and coarse sand(F.M.1.8 to 2.5)mortar in super structure in steps, parapet andfacia including nacessary cutting moulding of bricks andincluding supply of all materials labour & T & P required forproper completion of the work including placing & fixing ofreinforcement in position with 24 B.W.G. binding wire withcentering shuttering complete but excluding cost of reinforcementand its bending which shall be measured separately. 8 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 9 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 10 Cement concrete with 2cm gauge approved hard stone ballast,coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 3:1.5:1including supply of all materials, labour,side shuttering ifrequired and T&P etc. required for proper completion of work 11 R.C.C. work with cement, approved coarse sand and 2 cm. (3/4) gauge approved stone ballast in the proportion of 1:1.5:3 in the lintels of doors and windows excluding reinforcement and its bending but including its fixing and binding the same with 24 BWG, G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T&P etc. required for proper completion of the work. (Binding wire to be supplied by the contractor free of cost). 12 R.C.C. work with cement, approved coarse sand and 2 cm. (3/4) gauge approved stone ballast in the proportion of 1:1.5:3 in theraft foundation and footings, excluding reinforcement and its bending but including its fixing and binding the same with 24 BWG, G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T&P etc. required for proper completion of the work. (Binding wire to be supplied by the contractor free of cost). 13 R.C.C. work with cement, approved coarse sand and 2 cm. (3/4) gauge approved stone ballast in the proportion of 1:1.5:3 in RCC T- Beam Slab and Column excluding reinforcement and its bending but including its fixing and binding the same with 24 BWG, G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T&P etc. required for proper completion of the work. (Binding wire to be supplied by the contractor free of cost). 14 Concreting of 40 mm thick RCC trench covers in mild steel framework with RCC 1:1.5:3 in Cement,Chopan coarse sand(F.M. 1.8 to 2.5) and 2cm gaugegraded hard stone ballast with 3mm thick floating coat of neatcement finish on top of cover complete with all labour, materials and placing the same in proper position at required location of cable trench within the substation area. 15 Mild steel or iron work in heavy sizes such as trusses, built-up gates, door frames, record racks, roof work, gates etc. wrought to required form including drilling holes rivetting or welding where necessary and also fixing in proper position and alignment including supply of steel, nuts wastage etc. and their fixing as required for proper completion of the work. 16 Providing M.S. Frames work, rack etc for R.C.C. Trench covers and edging with M.S. angles and M.S reinforcement including cutting, bending and welding as per approved drawing. Therate is including cost of all labour, materials etc. as required for proper completion of the work. 17 Mild steel or iron in plain work such as reinforced concrete or reinforced brick work. (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel, its wastage, bend hooks, and authorized overlapping shall be measured. 18 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 19 Providing & fixing 1 mm.thick M.S. sheet garrage door with frameof 40x40x6mm angle iron,diagonal bracings with 50x5 mm flat and 5 mm thick M.S. gusset plates at thejunctions and corners including supply and fixing of necessaryfitting, 2 no lock rail of 16 dia,375 mm long and including pintel hooks at the top and bottom, applying a priming coat of red oxide paint on all sides complete . 20 Providing and laying floor of 10 mm thick industrialtiles in flooring or skirting of approved brand (Bell, Johnson or equi. make)size of 600x600 mmof approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of tile including cost of all material, labour and T&P required for proper completion of the work. 21 Providing and laying floor of 8 mm thick vitrifiedtiles in flooring or skirting of approved brand (Bell, Johnson or equi. make)size of 600x600 mmof approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of tile including cost of all material, labour and T&P required for proper completion of the work. 22 Same as 23 above but for providing and fixing 8 mm thick vitrifiedtiles in flooring or skirting with adhesive of approved quality on existing smooth floor including cost of all material, labour and T&P required for proper completion of the work. 23 Supply of 80 mm thick I shaped mechanically compressed rubber mould inter locking cement concrete paver block manufactured by high pressure & controlled vibration machine having plan dimension 200X(160+120 mm) with minimum 5 mm thick toping of O.P.Cement mixed with 25% marble powder. The compressive strength of concrete pavers blocks shall not be less than 30 MPa & 4.5 Kg/No. including cost of all material, labour, T&P etc. required for proper completion of work as directed by Engineer-in-charge but excluding G.S.T. which shall be paid extra as per rules. 24 S/F 8mm thick white glazed Somany, Johnson etc 1st Quality tilesin Flooring, laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supplyof all materials labour and Tools and Plants etc. required for proper completion of the work. 25 S/F 6 mm thick white glazed tilesin skirting / dado laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supplyof all materials labour and Tools and Plants etc. required for proper completion of the work. 26 12 mm (1/2) thick plaster with cement mortar in proportion of 1:6 cement and approved coarse sand over brick work, minimum thickness not to be less than 1 cm. (3/8) including supply of all materials, labour and T&P etc. required for proper completion of the work.(rates including cost of cement) 27 Same as item No 26 above but in proportion 1:4 cement & coarse sand. 28 Same as item No 26 above but in proportion 1:3 cement & coarse sand. 29 Add for extra labour and matarials for plaster over rough face of one brick wall. 30 3mm thick floating coat of neat cement finish over roof and wall with water proofing compound including cost of all materials, labours and T&Ps etc. required for proper completion of the work. 31 Providing/making drip course (25x12)mm in 1:2 cement & coarse sand mortar to a rectangular profession 25mm wide and 12mm thick to a out side of sunsheds and projected slab pattas etc. including cost of all materials, labours and T&P s etc. required for proper completion of work. (including cost of cement). 32 Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls &floors, around the external perimetre of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm, ( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external perimetre of building @ 7.5 Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials, labour, equipments, T&P complete. 33 Earth filling under floors and in substation area including cost of earth. Earth to be obtained from outside the Corporations area including its cartage and ramming, watering, dressing in 20 cm. thick layers and dressing of earth etc. complete including cost of earth with all lead and lift etc. complete. 34 Local river sand filling in plinth including supply of necessary quantity of sand from a distances not exceeding 8 Kms. (5 miles) from the site of work including watering ramming and dressing etc. Rate include cost of all materials, labour and T & P etc. required for proper completion of the work. 35 Laying cement concrete road slabconsisting of 1 part cement 2part approved coarse sand and 4 part approved 20mm down graded stone aggregate over prepared sub grade after its rectification and bringing it to proper camber and shape,finishing with TRIMIX machine ,concrete hardner and making good to the satisfaction of E/I inclduing cost of all materials, labour and T&P etc. required for proper completion of the work. 36 Filling of 20 mm. wide 100/150 mm. deep joint with coarse sand and saw dust mixed with hot bitumen etc. complete including supply of all materials, labour and T&P etc. required for proper completion of the work. 37 Providing and fixing 12mm thick particle board of commercial quality 125 mm deep for making partitions of C.C. road slab as per direction of E/I. including cost of all material, labour and T&P required for proper completion of work. 38 40 mm. thick C.C. 1:2:4 plain cement concrete with cement, approved coarse sand, and 2cm.(3/4) graded approved stone ballast laid in pannels finished with 3mm.(1/8) floating coat of neat cement and marble dust in ratio of 5:1 as specified over(without base concrete) and removing any over lapping mortar at the joints of the pannels, if any, and giving them a uniform finish including supply of all materials labour and T&P etc. required for proper completion of the work without base concrete. 39 Providing and fixing glass strips of 3.15 mm thickness & 40mm depth in jointsof floor and skirting at the time of laying floors, flush withfloor level including supply of all materials, labour& T&P etc. required for proper completion of work. 40 Applying Birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ICI or equivalent brand for smoothening and levelling of the surface as per requirement and direction of Engineer I/C including cost of all material, labour, T & P etc required for proper completion of work. 41 Painting Two Coat with APEXof Asian Paint or equivalent make including 3 coats of above and including one priming coat on already well preparied new wall surface to give an even shed including cost of all materials, labour and T & P etc. complete. 42 Painting Two coat with Acrylic emulsion paint of Berger/ Asian/ ICI or equivalent paint (Paint and water in the ratio 1:1 by volume) over prepared and primed surface of cement concrete, cement plaster and bricks including all labour, material and T&P etc required for proper completion of the work, (preparation of base with Birla putty etc. and a coating of primer shall be paid extra) . 43 Painting or varnishing new iron works or new wood work with one coat of ready mixed priming paint and two coats of approved superior quality ready mixed paint LUXOL or equivalent brand or varnish including supply of all materials, labour& T&P etc. required for proper completion of the work. 44 Providing and fixing steel glazed window and ventilators ofstandard rolled Mann or Mahavir steel sections conforming to IS7452-1974 as per drawing joints metered and welded with 100x14x3.15 mm holdfast embedded in cement concrete block15x10x10 cm. Size of 1:3:6 proportion I.E. First part of cement 3 part of approved coarse sand and 6 part of graded stone (aggregated 20mm. Nominal size) S/F of glass panes of plain pin headed 4mm. Thick nuts glazing clips and special putty of approved make complete and including a cost of red oxide paint. The fabrication should confirm to I.S.1038-1975. (Aluminum beading with rubber packing included). 45 Wiring Point for light with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 46 Same as above item no.45 but wiring for fan point. 47 Same as above item no.45 but wiring for plug point. 48 S/F Angle/Batten Holder. 49 Supply and fixing of switch box 100x100x50mm size of approved make made up of 1.00mm thick ISI Marked G.P. Sheet All 4 corners folded & spot welded for screw and holes plugged with PVC Nylon Caps. Two or more holes for pipe entry of 25.4mm on upper and lower sides of the box.Holes should be semi-shutterd type and fitted with heavy brss earth piller duly screwed & brand name should be embossed.Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper complection of work as directed at site by E/I Charge. 50 Same as in item N0. 49 But of 150x150x65mm size 51 Same as in item N0. 49 But of 175x100x65mm size 52 Same as in item N0. 49 But of 200x250x65mm size 53 Same as in item N0. 49 But of 250x250x65mm size 54 Same as in item N0. 49 But of 250x300x65mm size 55 Add for light/ fan points with modular type switch in place of piano type switch. 56 Add for 2 way light points with modular type switch in place of piano type switch. 57 Add for Plug points with modular type switch in place of piano type switch. 58 S/wiring Sub main with 2 No. 4sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 59 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 60 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 61 Supply and burying earth electrodes for lightening conductor of 600 mm. x 600 mm. x 6 mm. Copper Plate vertically with its top at least 3 meters below ground level complete with 20 mm. G.I. Plat vertically with its top atleast 3 meters below ground level complete with 20mm. G.I. Pipe for watering funnel, 30 cm. Square C.I. Frame with hinged cover masonry housing alternate layers of coke/ charcoal and salt at least 150 mm. thick alround etc. completed in all respects as per. 62 Supply and fixing of Surface/Flush mounting 4 ways V TPN distribution board with additional metel door without MCB complete in all respect, as directed at site by Engineer in charge. 63 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 64 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 65 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 66 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 67 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 68 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 69 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 70 A-from 0 M BGL to 90 M BGL.Drilling for 200mm dia bore from G.L. to M B.G.L., work to be completed as per direction of Engineer I/C . 71 B-from 90 M BGL to 120 M BGL. 72 C-from 120 M BGL to 150 M BGL. 73 A-from 0 M BGL to 90 M BGL (Lowering of tube well assembly alongwith shrouding with pea gravels, testing, verticality of Tube well and washing of the tube well from G.L. to 180 Meter B.G.L. the cost including all labour, materials, T&P required for proper completion of work but excluding the cost of slotted pipe/ plain M.S/PVC.pipe assembly and Pea gravel) 74 B-from 90 M BGL to 120 M BGL. 75 C-from 120 M BGL to 150 M BGL. 76 Providing110mm dia Plain PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 77 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 78 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 79 Supply and fixing of 110mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 80 Supply and fixing 32mm dia support clamps for column pipesmade out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. 81 Supply and stacking pee gravelproperly at levelled ground for measurement as directed by Engineer I/C, including all labour, T&P required for proper completion of work. 82 Lowering of M.S. column pipe in tubewell including supply of nuts, and bolts, packing and also carriage of pipe from workshop to site including all labour, T&P etc. required for proper completion of the work. 83 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. 84 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work. 85 Supply and fixing of Syntex or equivalent make water storage tank including all materials, labours, T&P etc required for proper completioon of work. 86 Providing and fixing PVC BALL FLOAT VALVE 15 mm dia. WITH BRASS & UNION COMPLETE, ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. 87 Supply and Installation of 32 mm dia outlet size submersible pump set 1.00 H.P.89/45 operating head, single phase, KSB or other approved ISI marked, standard equivalent make complete with all material, labour, T&P. 88 S/F single phase control panel board for single phase submersible pump sets of 1.00HP KSB / BEST or other approved make containg rotary on/off switch for mains, the ammeter, volt meter & starter with selector etc. complete in all respect. 89 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 90 Providing and fixing 15 mm dia ISI Approved CPVCpipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes concealed GI fitting where required, cutting and making good the walls etc and all materials, labour and T&P complete. 91 Providing and fixing 20 mm dia ISI Approved CPVCpipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes concealed GI fitting where required, cutting and making good the walls etc and all materials, labour and T&P complete. 92 Providing and fixing 32 mm dia ISI Approved CPVCpipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes concealed GI fitting where required, cutting and making good the walls etc and all materials, labour and T&P complete. 93 Supply and fixing brass bib cock/ stop cock of heavy quality 15 mm dia (400 gms) ISI mark including supply of all materials, labour, T&P etc complete. 94 Supply and fixing P.V.C. cistern Hindustan or equivalent make 10 litres. Capacity complte with all accessories (Low level) including all materials, labour and T&P etc complete. 95 Supply and fixing Nahani Trap India make of heavy approved quality complete with C.P. brass grating, Nahani Trap laid over base cement concrete 1:6:12 including cost of cement supply of all materials,labour and T&P etc. required for proper completion of the work. 96 Providing and fixing in position 32 mm. dia P.V.C. waste pipe for wash basin. with unions, bends etc. including supply of all materials,labour and T&P etc.required for proper completion of the work. 97 Supply and fixing of Angle valve including all materials, labour and T&P etc. required for proper completion of work as directed by E/I. 98 Providing and fixing white glazed China earthen ware water closet squatting Orisa type pan weaper size 580mmx140mm Hindustan Make or other equivalent approved make of Ist quality with 100mm dia. White glazed P or S trap fittings including cutting & making good the walls and floors wherever required with cement sand and grit mortar not less than 1:4 the seat and trap shall have to be fixed over minimum 3 thick c.c. in proportion of 12:6:1 including cost of all materials, labour. 99 Providing and fixing CP BRASS Piller cock HEAVY QUALITY ( L&K or equi. )fittings, ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. 100 Providing and fixing PVC CONNECTION PIPE, 450X15 with 2 brass units ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. 101 Providing and fixing flat back 465 mm.x 355 mm x 265 mm. size lipped front urinal basin of white glazed earthern ware first quality (Hindutan, Neycer make) I.S.I. marked including supply of all materials,labour and T&P etc. required for proper completion of the work. 102 Providing and fixing DIVISION PLATE 600X300 mm WHITE GLAZED FOR URINALS I.S.I. marked including supply of all materials,labour and T&P etc. required for proper completion of the work. 103 Providing and fixing in position 32 mm. dia P.V.C. flush pipe. for W.C. with unions, bends etc. including supply of all materials,labour and T&P etc.required for proper completion of the work. 104 Providing and fixing soap dish chromium plated with brackets fixed to wooden cleats with brass screws including supply of all materials,labour and T&P etc.required for proper completion of the work. 105 Providing and fixing 550X400 mm wash hand basin of white glazed earthern ware first quality I.S.I. marked (Hindustan,Neycer / Cera make) including supply of all materials, labour and T&P etc. required for proper completion of the work. 106 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 107 Marking of building and foundation in new sub-station (132/220 KV) in UPPCL land as per approved layout drawing with help of Theodolite/ total station instrument and closing of Travers for main Gantry etc including cost of all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 108 Making borehole in all type of soil by any method required as per site conditions in accordance with IS specification No 1982-1979 and 1498-1970 and conducting standard penetration test in accordance with IS specification No 2131 – 1981 at every 1.5 M approx . or as per strata during making borehole and also collecting undisturbed and disturbed soil samples at a depth of approx. 1.5 M depth or change of strata of soil as per site requirements in each borehole in accordance with IS specification 1892-1978. (Depth of water table as detemine from borehole or from nearest waterwell ) Each Boreholes to be bored upto 15.00 depth. 109 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983i) Tri axial compression test and determination of shear parameters(c &?) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soilii) Sieve analysis test as per ISS 2720 (Part iv)iii) Atterberg’slimit tests as per ISS –2720 (Part v)iv) Particle size analysis test as per ISS 2720 (Part iv)v) Natural moisture content test as per ISS 2720 (Part vi)vi) Wet density test and dry density test as per ISS 2720 (Part vi)vii) Specific gravity test as per ISS 2720 (Part iii) section 2Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as followsi) Sieve analysis test as per ISS – 2720 (part iv)ii) Atterberg’s limit tests as per ISS- 2720(Part v) 110 Conducting plate load test near CONTROL ROOM BUILDINGsite at specifed depthas per IS 1980-1982 including supply of all material, labour and T&P equipment and recording of test result as per Codal requirement and submission of report. 111 Consultancy services of Architect for Construction of Building Rate Total Project Cost@1%Providing consultancybasis for construction of SGR Building,and Boundary wall at 33/11 k.v.(1x5MVA) s/s Bhadin (Nagahara)Distt-Mau. (Plinth Area approximately 126.97 Sq. Mtr) including design and development of various drawings.(1)Drawing Required:- 1-Lay-Out Plan.2-Architectural design and structural design.for Double story Building3-Electrical system design (external and internal).4-Sanitary, plumbing, dranage, water supply.5- PERT Chart of work. 6- Periaortic inspection during construction of work. 7- Architectural design and structural design.for Boundary wall & Gate.3-D View drawing of front elevation, side elevation and Back elevationProject Management Consultancy as Required Modification in Layout/Drawings etc. during execution of actual work and using project management methodology to meet time bound complection of project as per millstones fixed in consultation with PuVVNL Certification of as-Build Drawings and any others requirement not specified but essential for making building fully operational to the satisfaction of user. 112 Providing and fixing of 110 mm dia PVC pipe 6 Kg/ Sq.cm forwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. 113 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 114 Providing and fixing 110mm dia SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work. 115 Providing and fixing 110mm dia SWR, PVC ( Finolex or equivalent )Trap including cost of all materials, labour and T&P etcrequired for proper completion of the work. 116 Providing and fixing 110mm dia SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work. 117 Providing and fixing 110mm dia SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. 118 Providing and fixing 110mm dia SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-06-2024 CORRIGENDUM Other 05-07-2024
2 22-06-2024 DATE EXTEND 01 Date 10-07-2024

Key Value

Document Fees
INR 7080 /-
EMD
INR 122000.0 /-
Tender Value
INR 60.90 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail