Tender For Proposed Tourism Development Work Of Gothani Shiv Temple At Chopan Distt- Sonebhdra, 1 (Civil work) 2 Dismantling existing plaster including disposal of refuse as directed by the engineer-in-charge with in a distance of 60metre (200ft) 3 Scraping old white or colour wash including disposal of refuse material as directed by Engineer-in-charge with a distance of 60met. (200 feet) 4 Dismantling cement concrete orbrick or granolithic floors including stacking of dismantled materialsasdirectedby Engineer-in-charge with in adistanceof 60 meters. 5 Dismantling reinforcement cement concrete orreinforcement brick work including stacking of dismantled materialsasdirectedby Engineer-in-charge with in adistanceof 60 meters. 6 Disposal of waste materials up to a distance of 10.0 Km. from the site complete loading, unloading, labour T&P. 7 Providing and layingin cement concrete 1:4:8 (1 cement :4 coarse sand :8stone grit 40 mm nominal size) and curing complete,including cost ofform- work,in foundation and floors. 8 Providing and laying cementconcrete approved coarse sandand2cm. (3/4) guageapproved stoneballastin the proportion 1:1.5:3,(1cement :2corse sand 4 grit) in including supply of all materials,labour andtools and plants etc, required forproper completion of the works. strength of the concrete shall not be less than M-15. 9 Providing and laying cementconcrete approved coarse sandand2cm. (3/4) guageapproved stoneballastin the proportion 1:1.5:3,(1cement :2corse sand 4 grit) in including supply of all materials,labour andtools and plants etc, required forproper completion of the works. strength of the concrete shall not be less than M-15. 10 Providing & laying brick Coba 12mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed 11 coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shal 12 ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. 13 12 mm cement plasterinsingle coat on rough sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth. (1) 1 cement : 6 Coars sand (2.25FM) 14 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 Coars sand (2.25FM) 15 12mm thick plaster in 1:4 on ceiling and soffitsof stairs upto floor two level (1) 1 cement : 4 Coars sand (2.25FM) 16 Engraving lines in the plaster of outer face wall vertically and horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labour & T& P etc. required for proper completion of the work. Add for extra labour to all items of plaster. 17 white marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of whitecement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marblechips of sizes from 1 mm to 4 mm nominal size by volume), with underlayer 25 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 12.5 mm nominal size), including rubbing,polishing and cement slurry etc. complete : 18 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 19 Red sand stone - 30mm thick gang saw cut stone 20 Wall painting with plastic paint of second quality approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer 21 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (apex Ultima, weather coat all guard) asian, berger. 22 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 23 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for therequired duration as approved and removing it there after .The 24 scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. 25 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat ofapproved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 26 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3 apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. 27 Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. 28 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 29 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 30 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering upto floor to level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6Coarse sand. 31 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 32 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) 33 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 34 ELECTRICAL 35 Wiring point for light with 1.0 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. 36 Wiring point for two ways light with 1.0 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and two number two way piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. 37 Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.0 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. 38 Wiring point for plug with 1.0 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and piano type switches & socket etc., complete in all respects as directed, including matching color wash. 39 Addition for light / fan points with modular type switchin place of piono type switch. 40 Addition for two way pointswith modular type switchin place of piono type switch. 41 Addition for HPSV/Exhaust Fan pointswith modular type switchin place of piono type switch. 42 Addition for plugpointswith modular type switchin place of piono type switch. 43 Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. 44 Supply & wiring of submains with two number4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. 45 Supply and wiring of submain with two number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand single core copper conductor cable in 20 mm dia. heavy duty (2 mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. 46 Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required. 47 Supply & fixing of factory wired, Box/ Channel type T-5 energy saver withoutreflector & without end covers for 1No. 28 watt T-5 lamp with 1 x 28 watt /2x 28 watt T-5 lampetc. complete in all respects. 48 1 x 28 watt T-5 49 2 x 28 watt T-5 50 Supply & fixing of factory wired HPF box type, flourescent tube light fitting suitable for 1x20 / 1x18 watt decorative mirror complete including tube etc.on surface complete in all respects. 51 Supply & Fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 watt. Confirming to ip 65 protection complete in all respect. 52 Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. 53 Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. 54 Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. 55 Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. 56 Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 5 - 32 amps.Cat. A 57 Supply and fixing of 40 Amp. 4 Pole MCB (10KA) 58 Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work.600x480x200 mm. size 59 Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followedby two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work.600x480x200 mm. size 60 Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge. 61 Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape,etc. complete in allrespects. 62 Supply and fixing of single pole MCB blanking plate 63 Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work. 64 Supply & fixingof Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2Pin and earth metal clad scraping earth plug and socket complete in allrespects as per direction and satisfaction of engineer-in-charge. 65 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. 66 Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. 67 Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properlyetc. complete as required. 68 Supplyfixingofelectronic fan regulator 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 69 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the 70 cable run shall be fixed on M.S. clamps etc. of suitable size. S.I.No.501(I) 10 sqmm 4 core 71 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire. 10 sqmm 4 core 72 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.10 sqmm 73 Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. 74 Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required -Make: Usha Cat No.SONATA MAX 75 Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX 300mm sweep. 76 Supply and Fixing of 12 to 18 watt L.ED. Bulb. 77 Renovation work of toilet block including repair plaster, painting, door, tiles, sanitary, electrical allwork etc under amount as direction by engineer. 78 BORING WITH SUBMERSIBLE. 79 External W/S arrangements with T.W. boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 1.5 to 3.00 H.P. Solar pannal withsubmersible pump including supply of all accessories starter, panel etc. & pipe arrangements etc . 80 110MM PVC casing pipe of ISI mark. 81 110MM PVC slotted pipe of ISI mark. 82 P/ F 50mm HDPEpipe. 83 Nylon mesh for filter. 84 Plastic dori. 85 Solvent cement. 86 110mm End cap. 87 110mm Submersible cap. 88 50mm MS clamp (Heavy). 89 50mmGI elbow. 90 50mm X 110mm GI nipple. 91 1.5 to 3.00 hpHP Solarsubmersible pump of ISI mark with automatic panel. 92 2.5 sqm. Submersible cable. 93 Drilling rock cuttingcharges for 6 dia tubewell. 94 Pea Gravel. 95 2 MS socket. 96 Cartage of material upto site. 97 Fixing testing and commissioning of Pumpset with lowering & Electric wiring with starter etc. complete as required. 98 DEVELOPMENT WORK. 99 P/Fixing of Signages incuding comple work as per direction by engineer. 100 P/Fixing ofRCCBenchesincuding comple work as per direction by engineer. 101 P/Fixing ofDustbins incuding comple work as per direction by engineer. 102 GST extra as per applicable