| 1 | M&L for excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth, for foundation, etc, or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 sqm on plan and n.exc. 1.5 m in depth and getting out in any type of soil, complete all as specified and directed. |
| 2 | M&L for plain cement concrete type D2 1:4:8 (40 mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 3 | Demolition of Pre cost concrete block masonry built in CM incl all quoins arches pillers etc complete all as specified. |
| 4 | M &L for precaste Cement Concrete block msonry with solid block ,Type C1 1:3:6 (using 20 mm graded aggregate) exc 10 cm in width and setting in cement mortar 1: 6extra all specified. |
| 5 | Form work to sides and soffits of floor or roof beams , lintels ,cantilevers, shelves etc finished rough surfaces of concrete flats, complete all as specified and directed. |
| 6 | M&L for PCC (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate in lintels upto 1.5 m clear span, cills, steps: seismic and other similar bands, plinth course, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, complete all as specified and directed. |
| 7 | Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for Drain cover . complete all as secified and directed by EIC. |
| 8 | M/L for External rendering 15mm thick on fair faces of brick work in CM 1:4 finished even and smooth with out using extra cement complete all as specified and directed. |
| 9 | M&L for rendering 10mm thick on fair faces ofbrick work or concrete surfaces of work in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/loose soil, complete all as specified and directed. |
| 11 | Removing excavated materials n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point in soils, complete all as specified and directed. |
| 12 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premis. complete all as specified and directed by Engr in charge. |
| 13 | M& L Non Skid ceramic joint free coloured tiles 7 to 8mm thick (square/rectangular) area of each tile over and including15 mm thick screed bed in cm 1:4 exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and joint free in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 14 | M & L for Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set over rendering 10 mm thick in cm 1:4 and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 15 | Demolition ofconcrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 16 | M&L for 25 mm thk PCC 1:2:4 type B-1 using 20mm graded agg as in flooring finished even and smooth without using extra cementcomplete all as specified and directed. |
| 17 | M&L 125 mm thickPCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base, finishing the surface even and rough to receive top layer complete all as specified and directed. |
| 18 | M&L forbroken stone or boulders hardcore of gauge n exc 63 mm deposited , spread and levelled and compected in layers n exc 15 cm thick complete all as specified and directed. |
| 19 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc any description all as specified and directed. |
| 20 | M&L for rendering 10mm thick on fair faces ofbrick work or concrete surfaces of work in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L 15 mm thick rendering on fair faces of concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified. |
| 22 | M&L for prepration of new plastered surfaces of walls and applyingtwo coats of cement base paintover a coat of primer complete all as specified. |
| 23 | M&L applying two coats of oil emulsion distemper over new surfaces of any description including chalk whiting and necessary preparation complete all as specified and directed. |
| 24 | Taking down galvanised steel tubing dia 15 mm and connections, including cleaning for refixing or removal to store.complete all as specified and directed. |
| 25 | S&F for Galvanised steel tubes, mediam grade 15 mm dia.complete all as specified and directed. |
| 26 | Taking up or down galvanised steel tubing dia 20 mm and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 27 | S&F for Galvanised steel tubes, medium grade, 20 mm dia, complete all as specified and directed. |
| 28 | S & F in repairfor Stainless sreel water closet pan (pedestal pattern), of size 584.2mm x482.6mm and 3mm thick,Oval shape (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 29 | S&F in repairs, PVC low level flushing cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed |
| 30 | S & F in repairs for stainless steel wash basin (304 grade heavy duty rust proof),grid type drain and rectangular in shape, size 500x300mmx150mm excluding taps, waste, chain and plug and porcelain stopper but including brackets with 32 mm waste coupling of PTMT (half or full threaded) (minimum weight 32 mm -45gms/40 mm-60 gms).complete all as specified and directed. |
| 31 | S & F Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms)complete all as specified and directed. |
| 32 | S & Fin repairs for Vitreous China bowl Urinal, flat back, white of size 465 x 355 x 265 mm with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, and connecting with supply and waste pipe complete all as specified and directed by Engineer Incharge. |
| 33 | S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm , complete all as specified. |
| 34 | S&F in repairs 15 mm dia bib tap cast copper alloy with butterfly handle fancy type chromium plated, screwed down for iron pipe or for brass ferrule and fixed complete all as specified as directed. |
| 35 | S&F in repairs 15 mm dia Pillar taps, cast copper alloy with capstan heads chromium plated fancy type , screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified as directed. |
| 36 | S & F in repairs15 mm bore dia Stop valves, cast copper alloy fancy type, chromium plated, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or forunions and fixed.complete all as specified and directed. |
| 37 | S & F for PVC connections 15 mm size with PTMT nuts of length 600mm. Complete all as specified and directed by Engineer -in- charge. |
| 38 | S & F in reepair for Grating doom 125 mm dia with waste hole of PTMT(minimum weight 40 gms) Complete all as specified and directed by Engineer Incharge. |
| 39 | S & F for urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. Complete all as specified and directed by Engineer Incharge. |
| 40 | S & F for 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercialplywood and fixed to wooden plugs with chromium plated brass screws and cup washers.complete all as specified and directed. |
| 41 | Dismantling plian or corrugated steel sheeting, any gauge, thickness, or similar pattern roof covering. |
| 42 | S&F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type orJ-type or cranked hook bolts in roofs, walls etc. with grade of zinc coating 275, etc complete all as specified and as directed. |
| 43 | S&F 0.63 mm thick Galvanised, plain mild steel sheeting in ridges, hips, valley gutters , drip and straight flashings (length and girth as fixed ) with grade of zinc coating 275 fixed to corrugated sheets in roofs, walls etc. , etc complete all as specified and as directed. |
| 44 | M&L for preparation of new zinc (or galvanised) comouflage pattern surfaces to receive painting, by a coating with mordant solution including washing and cleaning and applying two coat synthetic enamel paint over a coat of zinc crome, red oxide etc all as specified. |
| 45 | Taking down chowkats or frames exc.1.5 sq.m but n exc 4 sq.m each(without talking off shutters from the frame) |
| 46 | S &F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C\" channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. complete all as specified and directed. |
| 47 | Material & labour 2nd class hardwood plain, solidstraight chowkhats and frames, wrought, framedrebated on the solid,rounded or chamfered, puttogether with glue pinned at joints, 2nd class HW. complete all as specified and directed. |
| 48 | S&F 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 49 | S & F 200 mm size Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 50 | S&F Extruded Aluminium alloy handles, fabricated type, anodised 150mm size complete all as specified and directed |
| 51 | S&FButt hinges, 100mm medium weight mild steel cold rolled complete all as specified and directed. |
| 52 | S&Fmild steel ordinary rat tail rod pattern 300 mm long long door spring including roller and roller plateetc complete all as specified. |
| 53 | M&L for sliding door bolt of 300mm long plateAluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 54 | Dismantling of wall and ceiling boards (fPerspex sheet, fibre, pulp, insulation, etc.) or insulation boards/ slabs/blankets, any thickness, including any thickness complete all as specified. |
| 55 | Dismantling timber framed work in fillets, rails posts, rafters, purlins, etc. Under 40 Sq.cm in section etc. all as specified. |
| 56 | Dismantling timber framed work scantlings 40 sq.cm and over in section, in any position etc. all as specified. |
| 57 | M&L second class hard wood plain fillets square, rectangular or triangular in section area exc 6 sq.cm & n.exc 13 Sq.cm, clean sawn, se-cured with nails or brads complete all as specified. |
| 58 | M&L for second class hard wood timber framed in scantling fixed, clean sawn complete all as specified and directed. |
| 59 | Plugging to walls complete, for wood fillets, grounds, moulding, etc. on cement concrete walls, at distance n. exc 1 mtr complete all as specified and as directed. |
| 60 | S&F for 5mm thick transparent Perspex sheet fixing to aluminium frame /iron frame/wooden frame etc with self tapping screws/bolts etc complete all as specified and directed. |
| 61 | M&L for 6 mm thick Veneered decorative plywood, grade 1 (5 Nos of ply) (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work as in wall/panelling etc complete all as specified and as directed. |
| 62 | M&L for 6 mm thick Veneered decorative plywood, grade 1 (5 Nos of ply) (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work as in ceiling, flat or sloping, etc complete all as specified and as directed. |
| 63 | S & F Mild steel framded brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, guesset plates, riveting, etc..n exc 10kg each brackets, conforming to Fe.290.Gde |
| 64 | M & L for 75 mm thick PCC 1:3:6, type C-2 using 40 mm graded aggregates as in plinth protection laid in slope 1:30 in alternative bays not exceedings 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joinnts between panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and direcrted. |
| 65 | S&Ffor 500 ltr PUFInsulated water storage tanks (cylindrical vertical with closed top) incl connecting up pipes securing access covers incl ball brass valve 20 mm high pressure with polythene float and flynut ect complete all as specified and directed by Engr-in- Charge. |
| 66 | M&L inBall brass valves 20 mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 67 | M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade with grey cement and pigment.Complete all as specified and directed by Engr-In-Charge. |
| 68 | M&L Sand cushioning under floors or in foundations including watering and consolidation. |
| 69 | M&L for preparation of old painted steel surface of any description exceeding 10cm in width and girth and applying one coat of synthetic enamel paint as in camouflaging pattern over roof of bldg etc, complete all as specified and directed by Engr-in-charge. |
| 70 | M&L for preparation ofold surfaces and applying one coat of cement base paint in camouflage pattern etc complete all as specified and as directed by Engr-in-charge. |
| 71 | Hacking out old borken glass (any thickness size, quality or description) from wooden frme or stone concrete or brick surrounds, glaze with putty or fixed with beads, complete all as specified and as directed by Engr-in-Charge. |
| 72 | M&L 4 mm thick glass ordinary quality and glazing with oil putty/beads in square n exc. 0.50 sqm in each pane leaving the pane clean on completion, complete all as specified and as directed by Engr-in-Charge. |
| 73 | M&L for mild steel for wind ties for roof including securing bolts, screwing etc. & for doors, balusters, nosing to steps including embeding in concrete andposts and strutsincluding cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 completeall as specified and directed. |
| 74 | Taking down rainwater/soil waste & vent pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed by Engr-in-Charge. |
| 75 | M&L for PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by Engr-in-Charge. |
| 76 | M&L for PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints, fixed on walls, complete all as specified and as directed by Engr-in-Charge. |
| 77 | M&L for PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, fixed on walls/floor, complete all as specified and as directed by Engr-in-Charge. |
| 78 | Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and as directed by Engr-in-Charge. |
| 79 | S&F 100 mm cast iron,sand cast, soil,waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and as directed by Engr-in-Charge. |
| 80 | Taking down 16mm, 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and as directed by Engr-in-Charge. |
| 81 | Taking down 20mm, 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and as directed by Engr-in-Charge. |
| 82 | M&L for 16mm, 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and as directed by Engr-in-Charge. |
| 83 | M&L for 20mm, 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and as directed by Engr-in-Charge. |
| 84 | S&F in repairs 20mm PP-R Gate valves (brass insert) as per requirement of the site, complete all as specified and as directed by Engr-in-Charge. |
| 85 | Making connection of PP-Rpipe 16 to 40mm distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc, complete all as specified and as directed by Engr-in-Charge. |
| 86 | Taking down carefully existig copper / aluminium point wiring for light / fan / bell / socket 5/15 Amp points complete withfitting and fixtures such as switches, sockets, ceiling roses, holders and bracket fittings with battens / conduits / wires and making good the disturbed surfacesof walls and roofs etc.and to match with existing colour complete all as specified and directed. |
| 87 | M & L for Point wiring for one light point/ fan point/ Bell point controlled by one switch with 1.5 sqmm PVC insulated and unsheathed FR-LSHcopper conductor single core multi stranded flexible coppercable 1100 Volts grade conforming to IS-694 using approved colour code as per IS code drawn through non metallic rigid PVC casing Caping heavyduty double locked with size as persite requirement in accordance with clause No 19.25 of SSR Part I) ISI marked including casing caping accessories like bends, tees, junction boxes etc fixedwith all accessories suitable formodular type fitment including provision for fixing of modular surface boxes of suitable sizefor fixing ofmodular switches/sockets/regulator etc along with PVC insulated and unsheathed FR-LSH 1.5 sqmm multi stranded copper conductor cable 1100V (green color) as continuous earthlead wire connected to common earth and earth dollycomplete all as specified and directed by Engineer-in-Charge. |
| 88 | All as per serlItem No. 87 but for one 3 pin, 5Amp socket,Same board, complete, all as specified. |
| 89 | All as per serlItem No. 87 but for one 3 pin, 5Amp socket, independent board , complete, all as specified. |
| 90 | All as per serl item No. 87 but for 3 pin 15Amp socket outlet independent with PVC unsheathed, multistrand copper conductor of 2.5 Sqmm and continuous PVC insulated and unsheathed 2.5 Sqmm copper conductor cable multistrand as earth wire. |
| 91 | M & L for Modular switch single pole, one way, 6 Amps, 1 module, complete all as specified and as directed. Make LEGRAND/ HAVELLS/ ANCHOR |
| 92 | M & L for Modular switch single pole, one way, 16 Amps, 1 module, complete all as specified and as directed.Make LEGRAND/ HAVELLS/ ANCHOR |
| 93 | Modular socket, 6 Amps, 2/3 pin combined 2 module, complete all as specified and as directed.Make LEGRAND/ HAVELLS/ ANCHOR |
| 94 | Modular socket, 6/16 Amps, 2/3 pin combined 2 module, complete all as specified and as directed. Make LEGRAND/ HAVELLS/ ANCHOR |
| 95 | Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.Make ANCHOR/PLAZA OR EQUIVALENT AS APPROVED |
| 96 | Modular white cover plate with frame 3 module complete all as specified and as directed. Make LEGRAND/ HAVELLS/ ANCHOR |
| 97 | Modular white cover plate with frame 6 module complete all as specified and as directed. Make LEGRAND/ HAVELLS/ ANCHOR |
| 98 | Modular flush box 3 module complete all as specified and as directed. Make LEGRAND/ HAVELLS/ ANCHOR |
| 99 | Modular flush box 6 module complete all as specified and as directed. Make LEGRAND/ HAVELLS/ ANCHOR |
| 100 | S & F Ceiling rose surface type, PVC/polycarbonate ,isolated, bakelite 65 x 50mm, 3 terminals ISI marked. |
| 101 | S&F 9 Watt LED Base B22 Cool day Light complete all as specified and directed. Make Philips, Crompton, Havells |
| 102 | TakngdowenTubelight from its existtingposition andrefixing the same complete all as specifedand directed. |
| 103 | S&F LED tube light fitting 1 X 20 W , 220 V ,AC decorative boxtype with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiing rose complete all as specified and as directed .Make : Philips/ Havells/Crompton/ Bajaj |
| 104 | Supply & Fix in repair sheet metal enclouser DB\"s 4 way TPN single door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick with metallic painting white series, 415 volts 200 Amps rated enameled bus bar 16 way dust and vermin proof ssuitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. Make LEGRAND/ HAVELLS/ABB |
| 105 | Isolater MCB Triple pole neutral(TPN) 240 volts, 40 Amps, 10 KA complete all as specified. Make LEGRAND/ HAVELLS/ABB |
| 106 | MCB single pole(SP) 240 volts, 05 to 30 Amps, 10 KA complete all as specified.Make LEGRAND/ HAVELLS/ABB |
| 107 | Street light fitting, Pressure die-cast IP 66 LED street light, including LED lamps of 30 to 36 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, fixing in repairs, complete .Make : Philips/ Havells/Crompton/ Bajaj |
| 108 | Supply & Fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 50mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specifiedand asdirected by Engr-in-charge. |
| 109 | Earthing complete with copper plate elecrode of size60 cm x 60cm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead copperwire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of Copper earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to spoxsed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2022) |
| 110 | M&L for excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth, for foundation of poles /stays/cable. n. exc. 10 sqm on planand getting out in hard/dense soil, complete all as specified and directed. |
| 111 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in hard/dense soil, complete all as specified and directed. |
| 112 | M&L for PCC cable coverClass LV, Type I,flat,size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and directed. |
| 113 | Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge.Note: Punned thickness of sand shall be measured. |
| 114 | Supply, laying , testing and commissioning of 11 KVAXLPE Insulated ,galvanised steel or wire armoured electric poer cable (heavy duty) with aluminium conductor 1100 Volts grade laid in trenches or ducts or passing through road crossing, pipes, fixed on wall/poles of 4x25 sqm cross sectional area complete all as specified and directed. |