| Sl. No. | Item Description |
| 1 | Taking down existing old treatment including paddding, plaster of any description any type, roof tiles, cement mortar screed bed and removing existing bitumen felt treatment including brushing, brooming, cleaning top surfaces of roof slab to recieve plaster etc includingl disposing off debris from MoD land complete all as specified and directed. |
| 2 | Rendering 15mm thick cement plaster with cement mortar (1:3) fair finishes of brick work or concrete surface of roof slab, finished even and smooth without using extra cement including use of water proofing compound all as per manufacture instruction complete all as specified and directed. Note :- Water proof compound shall deemed to be included in the rate quoted by the contractor. |
| 3 | Roof treatment to RCC roof slab including parapet wall as under:- (a) Priming surfaces with bituminous primer conforming to IS-3384 @ 0.40Kg/sqm on prepared surfaces of plaster and after drying of primer, applying normal treatment (for moderate conditions) using glass fibre base bitumen felt, grade 2. (b) Applying evenly a tack coat of industrial bitumen grade 85/25 conforming to IS-702 at the rate of 1.2 kg per sqm including cleaning surfaces. (c) Provide APP (Atactic Polypropyline) based modified polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. APP membranne will be laid across the slop from lowest line of slopping roof toward ridge with minimumend overlap of 150mm and side overlap of 75mm bonded, sealed with hot blown and finished neat all joints.(d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as per IS 1203 will not be more than 40 confiming to IS 702 @ 1.20 Kg/Sqm including cleaning surfaces. (e) Preparation of new or previously untreated surface ofconcrete or surfaces of any description and applying two coats of aluminium paint overroof surfaces. Note :- Complete treatment shall be carried out by the applicator of the manufacturer only or through their authorised personal only. |
| 4 | Sunken Floor treatment :- Providing and laying of water proofing treatment to sunken floor portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementenious composite compound of make as specified and including demolition and including PCC 1:2:4 type B1 (20mm aggregate) as sub base, sides of rounded or chamfered on edges of sunken slab and PCC 1:5:10 type-E2 (using 40 mm aggregate) for filling of sunken floor after treatment. (a) First layer of cement slurry of cement @0.488 kg/sqm mixed with acrylic based primer modified cementenious composite compound @0.253 kg/sqm.This layer allowed to air cure for 4 hours.(b) Second layer of cement slurry of cement @0.242 kg/sqm mixed with acrylic based primer modified cementenious composite compound @0.125 kg/sqm. This layer allowed to air cure for 4 hours. (c) The slope shall be 1:20 towards the corner of outer wall and GI pipe of 50mm dia (Med grade) be inserted at corner projecting outside 20cm. (d) 15mm thick plaster in CM 1:3 mixed with WPC to be provided while concrete on green state. (e) Joints of trap/WC/Soil pipes shall be properly sealed with sealing compound.Note (i) :- Concrete for sunken slabs shall be mixed with WPC asmanufacturers instructions before carrying out water proofing treatment the sunken slabslab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested before passing for next stage. (Water proof compound shall deemed to be included in the rate quoted by the contractor.) (ii) Only floor area shall be measured for payment purpose. |
| 5 | Dismantling structural steel work including doors, gates, frame, truss etc of any description complete all as specified and directed. |
| 6 | Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality \"A\" complete all as specified and directed. |
| 7 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including ridges as in roof covering. |
| 8 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 9 | Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 10 | Dismantling of wall and ceiling boards including ceiling framework (fibre, pulp, insulation, etc,) or insulation boards/slabs/blankets any thickness, complete all as specified and as directed. |
| 11 | Dismantling of aluminium framework of false ceiling such as fillets, rails, posts, rafters, purlins, channel, runner etc. under 40 sqcm in section complete all as specified and as directed. |
| 12 | 4mm thick designer ceiling board, in ceiling fixed with screw as per manufactures instructions, laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanized steel sheet & of size 24x32x300mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4mm dia to be fixed by approved rowlplug, leveladjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200 long cross tee with (double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300mm long of white colour all as per instruction complete all as specified & directed. |
| 13 | Demolition of brick work built in cement mortar including all quions, arches , pillars etc. complete all as specified and directed. |
| 14 | Brick work with sub class \"B\" bricks , straight or curved on plan exc. 6 mtr mean radius built in CM (1:6) complete all as specified and directed. |
| 15 | Taking down cement plaster from brick or stone walls including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 16 | Rendering 15mm thick cement plaster with cement mortar (1:4) on fair faces of brick work or concrete surfacesand finished even and smooth without using extra cement including use of WPC all as be manufacture instruction complete all as specified and directed. Note :- WPC shall be measured and paid separately. |
| 17 | Rendering 10 mm thick cement plaster with cement mortar (1:6) on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed. |
| 18 | Applying 2mm thick wall care putty on internal walls complete all as specified and directed. |
| 19 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | Supply only Liquid water proofing compound. |
| 21 | Complete removal of exising treatment of old surfaces of walls complete all as specified and directed. |
| 22 | Preparation of newplastered and unplastered surfaces of walls and applying two coats of oil bound distemper over alkali resistant priming paint complete all as speicfied and directed. |
| 23 | Preparation of oldplastered and unplastered surfaces of walls and applying two coats of oil bound distemper complete all as speicfied and directed. |
| 24 | Preparation of newplastered and unplastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ltr and UV Resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm over new surfaces complete all as speicfied and directed. |
| 25 | Preparation of old plastered and unplastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ltr and UV Resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm over new surfaces complete all as speicfied and directed. |
| 26 | Preparation of old plastered and unplastered surface of ceiling and apply two coats of oil bound distemper complete all as specified and as directed. |
| 27 | Preparation of new Plastered surface and apply two coats of oil bound distemper over alkali resistant priming paint on ceiling complete all as specified and as directed. |
| 28 | Repairs to balcony/Facia and soffit of chajjas etc by taking down cement plaster any description and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30 sqm cm in width or girth and rendering 15mm to 20mm thick plaster in cement mortar (1:3) (to match with existing thickness) finished even and smooth without using extra cement including preparatoin of suface and applying two coats of cement base paint over one coat of primer including scaffolding work upto height of 7.0m complete all as specified & directed. |
| 29 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) roofs, floors (other then ground floors), beams, staircases, landing chajjas and similar suspended work complete all as specified and directed. |
| 30 | Reinforcement cement concrete (nominal mix) type B1 1:2:4 (using 20mm graded crushed stone aggregatge) as in Chajjas / Balcony / Landing work / Kitchen slab etc complete all as specified and directed. |
| 31 | Mild steel TMT bars 8mm dia and over cut to lengthbent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with and includig mild steel wire not less than 0.9mm dia or securing with clips complete fixed in repairs complete all as specified and directed. |
| 32 | Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including supports, overhangs, etc. complete all as specified and directed. |
| 33 | Reinforcement cement concrete(nominal mix) type B1, 1:2:4 (using 20 mm graded crushedstone aggregatge) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and inshelves and the like etc complete all as specified and directed. |
| 34 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Vertical , Horizontal or sloping) sidesincluding supports, overhangs, for fair finished surface of concrete flat complete all as specified and directed. |
| 35 | Demolition of stone slabs and tiles, laid bedded and pointed in any mortar of any description or thickness in floors, aprons, walls etc. complete all as specified and directed. |
| 36 | Green Marble work 18mm to 20mm thick (tabel rubbed and polished) atkitchen platform (Single Piece of slab for cooking Plateform)and like in cement mortar (1:4) including pointing in white cment (1:2) using marble dust with admixture of pigment to match with marble shade of Green marble including 15mm thick screed bed/base in CM 1:4,complete all as specified and directed. |
| 37 | Vitrified ceramic tiles 10mm thick (square /rectangular) polished, area of each tile not exceeding 0.36 sqm laid as in floors/skirting etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match in light shade including 15mm thick screed bed/base in cement mortar 1:4 complete all as specified and directed. |
| 38 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement mortar 1:4,complete all as specified and directed. |
| 39 | Glazed ceramic tile 450 x 350 x 7mm thick (coloured) on vertical surfaces such asdados etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering (Broomed) in cement mortar 1:4, complete all as specified and directed. |
| 40 | Machine cut kota stone slab flooring 20-25mm thick, over and including cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 41 | Machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar, over and including cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 10mm thick plaster in CM 1:3 complete all as directed. |
| 42 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and nexc 4.00 Sqm each complete all as directed. |
| 43 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) nexc 1.50 sqm complete all as specified and directed. |
| 44 | Pressed steel frames of sizes 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar complete all as specified and directed. |
| 45 | Pressed steel frames of sizes 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar complete all as specified and directed. |
| 46 | Factory made solid panel PVC door shutter/Cupboard shutter 30 mm thick (style) in consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colourPVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings. |
| 47 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed. |
| 48 | PCC 1:2:4 type B-O using 12.5 mm graded crushed stone aggregate as in filling of pressed steel frame and including 50 mm parapet coping including use of form work complete all as specified and directed. |
| 49 | PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and directed. |
| 50 | Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 51 | Powder coated aluminium Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges,door seal at bottom,anodised aluminum snap beading screws etc. (thickness of powder coating should not less than 50 micron) complete all as specified and directed. |
| 52 | Aluminium powder coated Anodised aluminium window (including glazed and skelton shutter ) and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.)suitable handle (1 no.) (thickness of powder coating should not less than 50 micron) complete all as specified and directed. |
| 53 | 35 mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 199 (Part-I).Flush door shutter shall be internally lipped as per clause 8.52.2 of SSR-2009 Part-I (Specification) complete all as specified and directed. |
| 54 | Factory made Glazed and skelton shutters 35mm thick second class hard wood, opened rebated and prepared to receive wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing wire mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a) complete all as specified and directed. |
| 55 | Mild steel springs for doors, 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 56 | 100 mmbutt hinges, medium weight cold rolled mild steel complete all as specified and directed. |
| 57 | Extruded Aluminium alloy handles, fabricated type anodised of size 150mm long (ISI marked) complete all as specified and directed. |
| 58 | Aluminiumanodised barrel tower bolt of extruded section 150 mm long (ISI Marked) complete all as specified and directed. |
| 59 | Hasp and staple 150 mm long safety type of aluminium anodised with hinge pin including bolt to hinge plate and fixed with screw as a cupboard locker complete all as specified and directed. |
| 60 | Aluminiumanodised sliding door bolts round nuckle with hasp and stapple extruded sectionor cast aluminium alloy 300 mm long complete all as specified and directed. |
| 61 | Box type steel windows/ ventilators with double shutters (inside for wiremesh & out side for glass), including guard bar, hinges, steel handle, towel bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide primer after preparation of surface before fixing, complete all as specified and shown on drgs No. CEUZ/TD-1517/15 sheet No. 1/3 to 3/3. |
| 62 | Box type steel windows/ ventilators with single shutters (without glazing bars), including guard bar, hinges, steel handle, towel bolt and steel peg stay complete including a coat of red oxide primer after preparation of surface before fixing, complete all as specified and shown on drgs No. CEUZ/TD-1517/15, sheet No. 1/3 to 3/3. |
| 63 | Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed complete all as specified and directed. |
| 64 | Sheet glass 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 65 | Figured glass sheet, 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 66 | Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,nodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed. |
| 67 | Renewal of Kitchen cabinets of PVC Solid board(wooden texture) size 900mmx750mmx600mm, including partitions, shelves and drawers with brass sliding rails,channels,door handles, door catchers, overall cabinet internally and externally madewith both side PVC laminated termite proof board, 18/19 mm thick, ISI marked including PVC kitchen/cup board frame of size 18mmx63mm made out of 18mm thick PVC pre-laminated ply coloured and frame shall be fixed with 50mm long steel screw inside using drilling machine and plastic fasteners, having following specifications:(i) Outer frame made six 50mmx47mm with same board.(ii) Shutters both side PVC laminated termite proof board, 18/19 mm thick having continuous piano stainless steel hinges of 30mm flap width with one No brass handle of 75mm including brass door catcher of not less than 50mm size in each shutter.(iii) Drawers made of both side PVC laminated termite proof board, 18/19 mm thick including brass handles of front and two sliding rails at sides in each drawer.(iv) All cabinets, drawers, frames, partitions and boards shall be fixed at site with brass machine screws and PVC plugs of suitable sizes. Note:(a) Only face/outer (3D) (Cuboid shape) diemensions (Length ,width and Height) at site, shall be measured and entered in MB irrespective of Nos of partitions or drawers. Cost of all partitions as required at site shall also be deemed to have included in quoted rates and nothing extra is admissible on this account. (b)Different No of partitions and drawers may be as per site requirement with out any extra cost.(c) All labours and materials cost shall be deemed included in quoted rate. |
| 68 | Pre laminated particle board,18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame work fixed in repairs as cupboard shelve and shutter complete all as specified and directed. |
| 69 | Extra over block board or veneered particle board of thickness 18/19 mm for external teak wood lipping, 6mm thick fixed with nails complete all as specified and directed. |
| 70 | Fixed in repair curtain rail, 20 mm dia mild steel ,chromium platedfixed with brakets,stops,rollers etc complete all as specified and directed. |
| 71 | Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier complete all as specified and directed. |
| 72 | Preparation of old steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with onecoat of synthetic enamel paint complete all as specified and directed. |
| 73 | Preparation of newuntreated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 74 | Demolition of concrete in ground floor and paving nexc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 75 | Providing cement concrete type B-1, 1:2:4 ( using 20mm graded stone aggregate), 50 mm thickas in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and smooth on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and directed. |
| 76 | Rotational moulded polyethylene water storage tanks of 1000 Litres capacity (ISI marked), (cylindrical vertical tanks with closed top) (White in Colour and three layered) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including Dismantling existing water tanks and removing to store complete all as specified and directed. |
| 77 | Taking up or down steel water tubing and connections of 20mm dia complete all as specified and directed. |
| 78 | Taking up or down steel water tubing and connections of 15 mm dia complete all as specified and directed. |
| 79 | 20mm dia mild steel galvanized steel tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 80 | 15mm dia mild steel galvanized steel tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 81 | 15 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed high pressure with crutch or butterfly handlefixed in repairs complete all as specified and directed. |
| 82 | 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed high pressure with crutch or butterfly handlefixed in repairs complete all as specified and directed. |
| 83 | Ball valve high pressure PTMT with epoxy coated aluminium rod& high density plastic ball 20mm dia bore complete all as specified and directed. |
| 84 | PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and directed. |
| 85 | Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) with\"P\" or \"S\" trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc, complete fixed in repairs complete all as specified and directed. |
| 86 | Fixed in repair plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device including demolition of existing seat all as specified and directed. |
| 87 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in repair in position complete all as specified and directed. |
| 88 | Fixed in repair Vitreous china squatting pan \"Orissa Pattern\" size 580 x 440 mmin any coloured with integral foot rest incl lime mortarand 110 mm bore \"P\" trap with connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor and complete all as specified and directed. |
| 89 | Vitreous china wall hung wash basin with fixing accessories, white, flat back, size 590mm x 490mm x 185mm full pedestal including 15mm bore CP Central hole Basin Mixer with Popup waste system with 450mm long braided hoses (Jaquar (Queen\"s Prime) Cat Part No. QQP-7169BPM) for mixing hot and cold water screwed down for iron pipe including 32mm dia waste coupling,waste pipe, cutting for and pinning in ends of brackets or erecting standporcelain stopper a pair of CI brackets fixed in repair complete all as specified and directed. |
| 90 | PVC connection 15 mm size with PTMT nuts 600 mm long complete all as specified and directed. |
| 91 | Aluminium anodised towel rail 20mm dia \"D\" type 60 cm longbetween flanges complete all as specified and directed. |
| 92 | Fixed in repair Brass Chromium plated shower roses 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union for fixing with 15 mm pipe, complete all as specified and directed. |
| 93 | Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), includding all fittings, heads, shoes bends, swan-necks etc. complete all as specified and directed. |
| 94 | 110mm bore PVC (SWR) Type-B pipes single socket, in any length with rubber joints, laid in floors etc all as specified and directed. |
| 95 | 75mm bore PVC SWR Type-B pipes single socket in any length with rubber joints, laid in floors, etc, complete all as specified and directed. |
| 96 | PVC (SWR) bends any radius 110 mm bore with access door complete all as specified and directed. |
| 97 | PVC (SWR) bends any radius 75 mm bore with access door complete all as specified and directed. |
| 98 | PVC (SWR) 110mm dia class B pipes in any length fixed to walls with PVC/MS holder but clamps and conforming to IS-1729 complete all as specified and directed. |
| 99 | PVC (SWR) 75mm dia class B pipes in any length fixed to walls with PVC/MS holder but clamps and conforming to IS-1729 complete all as specified and directed. |
| 100 | PVC Bends (any radius) diminishing pieces or tapers (larger bore measured) for pvcpipes, 110 mm bore complete all as specified and directed. |
| 101 | PVC branch pipes 110mm single equal or unequal ordinary or inverted (spigot or socket type) with paralled branches complete all as specified and directed. |
| 102 | PVC (SWR) 75 mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door complete all as specified and directed. |
| 103 | PVC (SWR)110 mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door complete all as specified and directed. |
| 104 | PVC junction, single, equal or unequal, ordinary or inverted with spigot or socket branch of 75mm bore with access door, complete all as specified and directed. |
| 105 | PVC cowls 75mm fixed in repair complete all as specified and directed. |
| 106 | PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 107 | Plate rack made of High quality stainless steel not less than 0.80mm thick overall size 910mm x 762mm x 254mm fixing by means of electrical drill machine, fasteners and screws, fixing in repairs, complete all as specified and directed. |
| 108 | Fixed in repairs, sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantileverbrackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed. |
| 109 | CP angle valve/stop cock (weight not less than 0.40kg) of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstan head screwed both ends for iron pipe 15mm bore incl fixed in repairs complete all as specified and directed. |
| 110 | 15 mm CP Bib taps Long body (weight not less than 0.40kg) fancy type chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and directed. |
| 111 | CP Brass wall mixer with provision for overheadshower arrangement with 115mm long bend pipe on upper side, for mixing hot cold water supply screwed down including connecting legs, CP extension nipple & wall flanges for iron pipe 15mm dia bore fancy type in repair complete all as specified and directed. |
| 112 | Brass CP mixer for sink, cast copper alloy (ISI Marked) fancy type chromium plated for mixing hot and cold water screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore incl connecting legs, CP extension nipple & wall flanges fixed in repairs complete all as specified and directed. |
| 113 | CP Soap dish any type fixed to plugs with chromium plated brass screws fixed in repairs complete all as specified and directed. |
| 114 | Corner glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long with brackets fixed in repair complete all as specified and directed. |
| 115 | Fixed in repair glass shelf 600mm long consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing with bracketscomplete all as specified and directed. |
| 116 | Toilet paper holder with flap recessed type stainless steel complete all as specified and directed. |
| 117 | Mild steel Framed work such as grills, Water tank stand, Cooler stand, gratings, (Incl fasteners for cooler stand) etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 118 | Bathroom mirror cabinet 400 x 500mm fixed to wall including complete accessories complete all as specified and directed. |
| 119 | Bevelled edge mirror 600x450mm size of selected quality on 6mm thick AC sheet or 6mm thick AC sheet or 6mm thick commercial plywood fixed to wdn plugs with CP Brass screws & cup washers fixed in repairs complete all as specified and directed. |
| 120 | Taking down carefully copper/aluminium point wiring (light, fan, llight socket or power socket) complete, incluing fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surfaces of wall, floor etc complete all as specificed as directed. |
| 121 | Taking down carefully copper/aluminum submainwiring from switch board to connected fitting/fixture complete all as specificed as directed. |
| 122 | Concealed sub main wiring of two run with 04 sqmm single core PVC insulated, FRLS,flexible multi stranded copper conductor cable 1100 volts grade, drawn through PVC conduit 20mm dia, med grade, ISI marked and fixed in concealed surface of wall, ceiling/false ceilling, including cutting /chasing as required and its accessories including one run of 4 Sqmm single core PVC insulated, FRLS, multi stranded copper conductor cable as earth continuity conductor in green color, connected to common earth dolly complete all as specified and directed. |
| 123 | Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLS,flexible multi stranded copper conductor cable 1100 volts grade, drawn through PVC conduit 20mm dia, med grade, ISI marked and fixed in concealed surface of wall, ceiling/false ceilling, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLS, multi stranded copper conductor cable as earth continuity conductor in green color, connected to common earth dolly complete all as specified and directed. |
| 124 | Point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade (MMS) andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. flush mountingSS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved colouresandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surface complete all as specified and directed. Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only. |
| 125 | One light point controlled by one switch complete all as specified and directed. |
| 126 | One ceiling fan point controlled by one switch complete all as specified and directed. |
| 127 | One bell point controlled by one switch complete all as specified and directed. |
| 128 | One exhaust fan controlled by one switch complete all as specified and directed. |
| 129 | One socket outlet 05 Amps on the same board complete all as specified and directed. |
| 130 | One socket outlet 05 Amps on independent board complete all as specified and directed. |
| 131 | One light point controlled by two way switch complete all as specified and directed. |
| 132 | Point wiring complete with 2.5 sqmm PVC insulated, FRLStype, ISI marked, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade (MMS) andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. modular metal flush box with top, bottom, side/ back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved colouresandincluding 2.5 Sqmm PVC insulated multistranded FRLStype unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directed.Note:- Allnecessary accessories such asmodular steelbox, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only. |
| 133 | Ceiling rose, 3 terminal, PVC/Polycarbonate body body (ISI marked) complete all as specifiedand directed. |
| 134 | Modular type switch, 1 way, 6 Amp, 1 module, 240 volt complete all as specified and directed. |
| 135 | Modular type switch, 2 way, 6 Amp, 1 module 240 volt complete all as specified and directed. |
| 136 | Modular type switch, 16 amps, single pole, 1 way, 1 module, 240 V, (ISI marked) complete all as specified and directed. |
| 137 | Modular type socket shuttered type 6 amps 2/3 pin combined 2 module 240 V AC (ISI marked)complete all as specified and directed. |
| 138 | Modular white cover plate with frame 2 module complete all as specified and directed. |
| 139 | Modular white cover plate with frame, 3 module complete all as specified and directed. |
| 140 | Modular white cover plate with frame, 4 module complete all as specified and directed. |
| 141 | Modular white cover plate with frame, 6 module complete all as specified and directed. |
| 142 | Modular type socket 6A/16A, 2/3 pin combined shuttered socket 2 module 240 V, AC (ISI marked) complete all as specified and directed. |
| 143 | Angle lamp holder, insulated body with back plate for bulb complete all asspecified and directed. |
| 144 | Callingbell, Ding dong AC, 230 volt, single pole complete all asspecified and directed. |
| 145 | Modular Bell push 6 A, 1 module, 240 V, ISI Marked complete all as specified and directed. |
| 146 | Renewal of LED Lamp retrofit type 12 watt B22 base holder with polycarbonite body and heat sink type complete all as specified and directed. |
| 147 | Renewal of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all asspecified and directed. |
| 148 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all asspecified and directed. |
| 149 | LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all asspecified and directed. |
| 150 | LED INVERTER batten 20Wdecorative box type light fitting,charging time 10 hour,emergency backup time 4 hours, energy efficiency inbuilt dry battery & driver, pre-wired, rated voltage 230Volts, 50Hzand connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed. |
| 151 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all asspecified and directed. |
| 152 | Exhaust fan steel body AC single phase 230 volts of size 300mm sweep with bladed, any frame and louvers 300 mm sweep, 900 rpm, 240Volts, AC, 50Hz as approved colour and connecting of electrical connections and testing complete all as specified and directed. |
| 153 | Fan regulator modular type electronic step type 120 watts, 2 modules 240volts AC ISI Marked complete all as specified and directed. |
| 154 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all asspecified and directed. |
| 155 | Renewal of sheet steel enclosure for flush/surface mounting distribution board, factory made and tested complete, protection class IP 36 suitable for mounting MCBs with 200 Amps tinned copper bus bar, cable lugs complete of the following capacity :- |
| 156 | Single pole & neutral, 8 ways 240 volts double door. |
| 157 | Single pole & neutral, 12 ways 240 volts double door. |
| 158 | MCB single pole & neutral, 40 Amp to 63 Amp \"C\" series 240 volts 10KA repturing capacity complete all asspecified and directed. |
| 159 | MCB single polet, 6 to 32 Amp, \"C\" series 10KA240 Volts 10KA repturing capacity complete all asspecified and directed. |
| 160 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM, RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. |
| 161 | Supply, installation, commissioning and testing Polycarbonate CPRI approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers makeHensel/Clipsal.The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. OneMain IncomerMCCB 125A TP 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nos Operated by Flip Cover. Indicator Provided on each phase. eight Nos Single Phase Sub-Meters. Output supply by MCB DP 32 Amp 8 Nos. Meter Enclosures & Enclosures Accessoriesas per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make :- Hense, Rittal, Emitter, Schneider. |
| 162 | Electric water heater, storage type steel body with copper inner tank and heating element 2 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. |
| 163 | Single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB of capacity 20 amp 240 volt and connecting electrically includingtaking down unserviceable MCB complete all as specified and directed. |
| 164 | Taking up or down GI pipe including fitting fixture of pipe size 50mm dia bore complete all as specified and directed. |
| 165 | Taking up or down GI pipe including fitting fixture of pipe size 25mm dia bore complete all as specified and directed. |
| 166 | 50 mm dia GI tubing medium grade with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc, as required at site and fixed on wall/ceiling or laid in floor or trenches complete all as specified and directed. |
| 167 | 25 mm dia GI tubing medium grade with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc, as required at site and laid in floor or trenches complete all as specified and directed. |
| 168 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in any type of soil, complete all as specified and directed. |
| 169 | Returining filling in including spreading, levelling, watering and wall ramming in layers not exc 25cm in any type soil complete all as specified and directed. |
| 170 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 171 | Cutting the existing 50mm tubing and inserting new GI Tee of size 50 x 50 x 25mm dia and including necessary screwing threading, tail pieces, short pieces, jointing material etc complete all as specified and directed. |
| 172 | Renewal of gun metal, globe or gate valves25mm borewith iron wheel head, screwed both ends from iron pipe and fixed complete all as specified and directed. |
| 173 | Taking down exisitng unserviceable cable of size 25sqmm x 4 core complete all as specified and directed. |
| 174 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm, 3.5 core including taking down old unserviceable cable, complete all asspecified and directed. |
| 175 | Sub class \"B\" bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid complete all as specified and directed. |
| 176 | Sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. Note :- For measurement purpose punned thickness 18 cm shall be considered. |
| 177 | 50 mm dia GI tubing, Light grade with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc, as required at site and fixed on wall/ceiling or laid in floor or trenches for cable protection all as specified and directed. |
| 178 | Pre-cast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs and similar articles with plain faces set in cement mortar (1:6) complete all as specified and directed. |
| 179 | PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles including use of necessary form work complete all as specified and directed. |
| 180 | Demolition and breaking up drain pipe of 150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including bends, complete all as specified and directed. |
| 181 | RCC class NP3 150mm dia drain pipes, laid in trenches and jointed complete with all collars directed. |
| 182 | Concrete bed to drain pipes 1:3:6 type C-2 using 40mm graded crushed stone aggregate including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe complete all as specified and directed. |
| 183 | Cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 184 | LLDPE septic tank conventional type for 20 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete all as specified and directed. |
| 185 | Construction of Soakage well (Brick construction) 2.4m dia and 4.5 m deep (internal dimension) below inlet pipe level (depth of inlet pipe to ground level 45cm), complete all as specified and shown on drawings No. CEUZ/TD/1585/21 sheet 1/4 to 4/4. |
| 186 | Deduction to be made from BOQfor Sch \"A\" Part - II (Schedule of credit) Amount of Rs. 5,01,720.00 during AOC.Note: Tenderers shall not quote for this schedule. |