}

Tender For As As To Building No P-96(Open Air Theatre/Green Room) At Old Nausena Baugh, Visakhapatnam, visakhapatnam-Andhra Pradesh

Statutory Bodies & Commissions/Committees has published Tender For As As To Building No P-96(Open Air Theatre/Green Room) At Old Nausena Baugh, Visakhapatnam. Submission Date for this Tender is 16-05-2024. Building Work Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43243135
Corrigendum : Tender For As As To Building No P-96(Open Air Theatre/Green Room) At Old Nausena Baugh, Visakhapatnam
Open Tender
Indian
Andhra Pradesh
Visakhapatnam
16-05-2024

Tender Details

Tender For As As To Building No P-96 ( Open Air Theatre / Green Room ) At Old Nausena Baugh, Visakhapatnam; 1 Demolition Of Un-Reinforced Cement Concrete In Ground Floors And Pavings Not Exceeding 15 Cm Thickness, ( Below Or Above Ground Level ) Complete All As Specified And Directed. 2 Demolition Of Un-Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For And Removing Rubbish To Outside Md Land Complete All As Specified And Directed. 3 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) And Disposal Ofdebris And Rubbish To Outside Md Land Complete All As Specified And Directed. 4 M&L For Non-Skid Coloured Ceramic Joint Free Tiles With Tile Spacer Of Minimum 3 Mm Thickness & In Light Shade7 To 8Mm Thick , Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38Sqm In Floors Set And Jointed With Epoxy Grout And Masking Tape And Pointedin White Cement Or White Cement Mixed With Colour Pigment To Match The Shade Of The Tileincluding 15 Mm Thick Screed Bed In Cement Mortor 1:6 A Complete All As Specified And Directed. 5 All As Per Item No 04 Here In Before But As In Skirting , Dados Etc. Set And Jointed In Neat Epoxy Grout And Masking Tape Over A Bedding Layer Of Backing Coat 10 Mm Thick In Cm 1:4 And Pointed In White / Colour Cement To Match Complete All As Specified And Directed. 6 M&L For Glazed Ceramic Tiles In Vertical Surface 450 X 350 / 450 X300 , 7 To 8 Mm Thick With Tile Spacer Of Minimum Thickess 3Mm , Set And Jointed With Epoxy Grout And Masking Tape And Pointedin White Cement Or White Cement Mixed With Colour Pigment To Match The Shade Of The Tile Includingbedding Layer Of Backing Coat 10 Mm Thick In Cm 1:4Complete All As Specified And Directed. Note : Rate Includes For Cuttingfor Offsetsetc 7 M & L For 25 Mm Thick, Plain Cement Concrete 1:2:4, Type B-0 ( Using 12.5 Mm Graded Stone Aggregate ) As In Sub-Base Of Flooring, Etc And Finished The Surface Even And Rough Complete All As Specified And Directed. 8 Taking Up Or Down Steel Tubing 15Mm Dia Bore Including All Connection Complete All As Specified And Directed 9 Taking Up Or Down Steel Tubing 20 Mm Dia Bore Including All Connection Complete All As Specified And Directed 10 Supply, Laying, Connection And Testing, 20 Mm Outer Dia Of Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified And Directed 11 Taking Up Or Down Steel Tubing 25 Or 32 Mm Dia Bore Including All Connection Complete All As Specified And Directed 12 Supply, Laying, Connection And Testing , 25 Mm Outer Dia Of Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified And Directed 13 Taking Up Or Down Steel Tubing 40 And 50 Mm Dia Bore Including All Connection Complete All As Specified And Directed 14 Supply, Laying, Connection And Testing , 40Mm Outer Dia Of Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified And Directed 15 Supply, Laying, Connection And Testing , 50 Mm Outer Dia Of Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified And Directed 16 Taking Down Eaves Gutters And Rainwater Pipes ( Any Size Or Pattern ) , Including All Fittings, Heads, Shoes, Bends, Swan-Necks, Etc., Including Cleaning Or Refixing Or Removal To Store ( Measured Overall As Fixed Along The Centre Line Over Fittings And Accessories ) 17 S&F Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls75mm Bore Including Necessary Bracket, Clamp Etc Complete All As Specified And Directed. 18 S&F Pvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls110mm Bore Including Necessary Bracket, Clamp Etc Complete All As Specified And Directed. 19 S&F Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors 75Mm Bore Complete All As Specified And Directed. 20 S&F Pvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenchs110mm Borecomplete All As Specified And Directed. 21 S & F In Repair 75 Mm Bore, Pvc ( Swr ) Floor Trap, With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete Type B-1 ( 1:2:4 ) Complete All As Specified And Directed. 22 S&F Pvc ( Swr ) Bends Any Radius 75Mm Bore Complete All As Specified And Directed. 23 S&F Pvc ( Swr ) Bends Any Radius With Access Doors 75 Mm Borecomplete All As Specified And Directed. 24 S&F Pvc ( Swr ) Bends Any Radius 110Mmborecomplete All As Specified And Directed. 25 S&F Pvc ( Swr ) Bends Any Radius With Access Doors 110Mm Borecomplete All As Specified And Directed. 26 S & F 75Mm Bore, Pvc ( Swr ) Branch Piece, Single ( Single Y ) Equal Orunequal Complete All As Specified And Directed. 27 S & F 75Mm Bore, Pvc ( Swr ) Branch Piece, Single ( Single Y ) Equal Or Unequalwith Access Door Complete All As Specified And Directed. 28 S & F 110 Mm Bore, Pvc ( Swr ) Branch Piece, Single ( Single Y ) Equal Or Unequal Complete All As Specified And Directed. 29 S & F 110 Mm Bore, Pvc ( Swr ) Branch Piece, Single ( Single Y ) Equal Or Unequalwith Access Door Complete All As Specified And Directed. 30 S & F 75Mm Bore, Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequal Complete All As Specified And Directed. 31 S & F 110 Mm Bore, Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequal Complete All As Specified And Directed. 32 S&F Pvc ( Swr ) Vent Cowl 75 Mm Borecomplete All As Specified And Directed. 33 S&F Pvc ( Swr ) Vent Cowl 110 Mm Borecomplete All As Specified And Directed. 34 Chipping Of Unsound / Weak Concrete Materials From Slabs , Beams, Columns , Lintel, Chajja, Fin , Facia Etc. ( Upto 50Mm Average Thickness For Slabs / Chajja ) By Any Means As Directed By Engr-In-Charge Including Tapering All Edges, Making Square Shoulders Of Cavities Air Or Sand Blasting Etc And Cleaning Of Exposed Concrete Surface Of Lightly Picking Materials By Air Blasting Or Sand Blasting Incl Foreign Matrials , Loose Concrete / Aggregate Etcand Disposal Of All Debris Out Of Mod Land And Complete All As Specifiedandas Directedby Engr-In-Charge ( Upto 4 Storey Of Building ) 35 Removing Of Concrete All Around Reinforcement Bar Upto 12 Mm Dia From Behind The Reinforcing Bars Average 25Mm ( But Not Less Than 15Mmair Gap ) By Manual Methods ( Using Wire Brushing , Chiselling Etc ) Removing All Rust From Steel Reinforcement Bar By Emery Paper And Cleaning The Area Throughly By Water And Allow It To Dry Andtotally Rust Free And Applying Two Component Epoxy Zinc Rich Primeron Existing Reinforcement Surface Ofminimum Specific Gravity 1.75, Adhesive Bond Strength With Steel Is 1.50N / Mm2and Maximum Coverage Area 5.00 Sqm Per Litreincluding All Necessary Scaffolding Complete All As Specified And Directed. ( Upto 4 Storey Of Building ) Make- Nitozinc Primer Of Fosroc Or Equivalents Chemical Of Sika / Stp / Hindcon As Approved By Ge. 36 All As Per Item No 35 Here-In-Before But Above 12 Mm Dia Bar 37 Providing And Applying Two Component Epoxy Bonding Agent ( Adhesive Bond Strength =11 N / Sqmm ) For Bonding Fresh Wet Cementitious Materials To Existing Cementitious Surfaces Bonding Agent Of Approved Brand Including All Necessary Scaffolding, Complete All As Per Manufacturer Instruction .Make :- Nitobond Ep ( Std ) Of Fosroc Or Equivalents Chemical Of Sika / Stp / Hindconas Approved By Ge. 38 M&Lfor Introducing New Reinforcement Bars Upto 12 Mm Dia For Structural Connection In Rcc Beams, Columns, Lintel And Slabs Including Power Drilling Holes Of Appropriate Diameters In Reinforced Or Plain Cement Concrete To A Minimum Depth Of 150Mm And Upto 200Mm Including Power Drilling, Fixing The Reinforcement In Position Using Epoxy, Cleaning Of Loose Dust By Blowing Air, Sealing With Epoxy Cartridges Etc All As Specified And Directed. ( Upto 4 Storey High. ) Make :- Hilti Hy 150 / Fosroc Lockfix E 75 Chemical Or Quivalents Solutions Sika / Stp / Hindconas Approved By Ge. 39 All As Per Item No 38 Here In Before But Over 12 Mm Dia Bar Upto 4 Storey High Complete All As Specified And Directed. 40 Supply, Materials And Application Of Two Component Structural Grade Polymer Modified Reinstatement Mortar Of Minimium Compressive Strength 12N / Mm2 In 1 Day And 45N / Mm2 In 28 Days. Minimum Flexural Strength Should Be 8 N / Mm2 In 28 Days. Single Component Acrylic Polymer Emulsion To Be Applied @ 6-8 Sqm / Lit Before The Application Of Modified Polymer Mortar .The Morter Shall Be Applied In Layers Exc 5 Mm Thick In Layers And Including Surface Preparationand Upto 4 Storey High. ( Maximum Coverage Area 1.3 Sqm At 10 Mm Thikness Per 25.25 Kg Bag ) Note:- This Item Shall Be Execution Where Shuttering Is Not Possible Or Small Patch Repairs Of Structural Elements .Make: ( A ) Acrylic Polymer Emulsion Primer : Nitobond Ar Of Fosroc Or Equivalents Solutions Sika / Stp / Hindcon As Approved By Ge. ( B ) Polymer Modified Reinstatement Mortar:- Renderoc S2 Of Fosroc Or Equivalents Solutions Sika / Stp / Hindcon As Approved By Ge. 41 Material & Labour For Providing And Placing In Position Free Flow Non Shrink Cementious Microconcrete Of Grade Of M-50 To The Effected Beam, Column Etc. The Micro Concrete Shall Have A Minimum 1 Day Compressive Strength Of 10 Mpa And 28 Days Strength Of 50 Mpa, Minimum Tensile Strength 5N / Mm2 @ 28 Days, Minimum Flextural Strength 5N / Mm2 @ 28 Days And Complete All As Specified And Directed By Engineer-In-Charge. 50Mm Average Thickness Of Column, Upto 4 Storey Building Including Surface Preparation & Suitable Type Formwork Etc. As Per Manufacturers Instruction.Make ( Micro Concrete ) :-Renderoc Rg Of Fosroc Or Equivalents Solutions Sika / Stp As Approved By Ge. 42 Demolition Of Cement Concrete ( Unreinforced ) In Any Position Not Otherwise Specifically Provided For As In Roof Padding Etc Including Old Detoriated Roof Treatment And Bedding Layer And Removing Debries And Rubbish To A Distance Outside Md Land Complete All As Specifed And Directed. 43 M & L For Brushing Neat Cement Slurry With 3.00 Kg Of Cement Per Sqm Complete All As Specified And As Directed 44 Material & Labour For 25 Mm Thick Cement Concrete ( 1:2:4 ) Type B-0 Using 12.5 Mm Gaded Stone Aggregate Laid On Rcc Roof Slab To Make Surface Levelled For Proper Slope Finish The Surface Even And Fair Complete All As Specified And As Directed. 45 M & L For 10 Mm Thick, Screed Bed As In Roof In Cement Mortar 1:4 On Fair Faces Of Brick Masonry Or Concrete Surfaces And Finishing The Surfaces Even And Smooth Without Using Extra Cement Mixed With Water Proofing Compound As Per ManufacturerS Instructions Complete All As Specified And Directed. ( Note: Wpc Shall Be Measured And Paid Seperately ) 46 M&L For Preparation Of Horizontal Or Vertical Surfaces For Water Proofing Treatment On Existing Cleaned Non Accessible Rcc Roof With The Following Specification And Manufacturings Instruction Complete All As Specified And As Directed:- ( A ) Preparing And Cleaning Of Fully Dry Surfaces As Per Is3067-1966 ( B ) Applying Bitumen Primer ( 85 / 25 Grade ) Conforming To Is:3384-1968 Over The Cleaned Plaster Surface @ 0.5 Ltr Per Sqm By The Same Membrane Manufacturer Of Density At 25°C, 0.87 To 0.89 Kg / Liter And Viscosity 70-160 Cps Shall Be Applied On The Prepared Surface. ( C ) Applying A Layer Of App Based Polymeric Membrance 3.0Mm Thick ( Minimum ) Weight 3.6Kg Per Sqm ( Reinforced ) With Polyster Non Woven Fabric Weighing Not Less Than 160Gms Per Sqm By Torch Application.The Over Laps Shall Be Minimum 100Mm On The Transverse Direction And 75 Mm On Longitudinal Direction. ( D ) Applying One Coat Of Aluminium Paint @0.10 Ltr Per Sqm Over App Based Polymeric Membrane. 47 Supply Only Integral Water Proofing Compound ( Isi Marked ) Complete All As Specified And Directed. 48 Dismantling Plain Or Corrugated Steel Sheeting, Of Any Gauge, Thickness, Includingnainital Or Similar Pattern Roof Coverings Complete All As Specified And Directed 49 Excavating In Post Holes ( Or Similar Holes ) Each N. Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers N. Exc 25Cm, Watering And Removing Surplus Soil To A Distance N. Exc 50M And Making Good Surface In Soft / Loose Soil Complete All As Specified Anddirected. 50 Removing Excavated Material Exc. 1.50 Km But N Exc. 5 Km And Depositing Where Directed Complete All As Specified And Directed 51 M & L For Plain Cement Concrete 1:3:6, Type C-2 ( Using 40 Mm Graded Stone Aggregate ) As In Foundation, Filling And Mass Concrete, Etc Complete All As Specified And Directed. 52 M&L For Rolled Mild Steel Work Conforming To Fe 410 -W ( Gde E- 250 ) Quality Aas In Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channelor Flat Sections ) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed. 53 S & F Ms Steel Work In Tubular Trusses Including Special Shapedwasher Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I.S. 1161-1979 Grade St-240 Complete All As Speicfied And Directed. 54 S & F Rolled Mild Plates ( Plain Or Chequered ) Channels, Square Cut Or Notched, Forming Holes With Riveted, Bolted Or Welded Attachment Conforming To Fe 410W Gr E-250, Quality-A Complete All As Specified And Directed. 55 S & F Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Dia Of Neck 16-20Mm , Length Of Bolt Exc 15Cm And N Exc 22.5Cm Long Complete All As Specified And Directed. 56 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Per ManufacturerS Instruction Complete All As Specified And Directed. 57 S&F Pre-Paintedgalvatume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Ridges , Valley Gutter Etcfixed With Self Tapping Screws Complete All As Specified And Directed. 58 M & L For Preparation Of New Steel Surfaces Of Any Description, Over 10 Cm In Width Or Girth, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide, Zine Chrome Primer Complete All As Specified And Directed. 59 Supply And Fixing In Repair Vitreous China ( White ) Wash Down Water Closet Pan ( Pedestal Pattern ) With P Or S Trap Front Or Back Inlet, Fixing Bolts ( Except Flushing Cistern And Flush Pipe ) Incl Plastic Water Closet Seat Cover ( White ) And Mild Steel Chromium Plated Or Aluminium Hinging Device Complete All As Specified And Directed By Engr-In-Charge.Make: Hindware Cat No. 20044 Or Equivelant Of Make As Per List Of Manufacturer 60 S & F In Repairs, 10 Litre Capacity, Pvc Valve Less Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Flush Pipe, Float And Handle Including Brackets Complete All As Specified And Directed.Make: Prayag Cat No.503 Or Equivelant Of Make As Per List Of Manufacturer 61 S & F In Repairwash Hand Basin, Vitreous China ( Flat Back Or Angle Back Type ) / Oval Shape Any Size, Including Cutting For And Pinning In Ends Of Brackets Or Erecting Stand Of Size 550 X 400Complete All As Per ManufacturerS Instructions And As Required At Site. Make:Hindware Cat No 10100 Or Equivelant Of Make As Per List Of Manufacturer 62 S & F In Repair 15 Mm Bore, Swan Neck Pillar Taps, Brass Chromium Plated, Single Lever Screwed For Iron Pipe Complete All As Specified And Directed.Make: Prayag Cat No. 6114 Or Equivelant Of Make As Per List Of ManufacturerS 63 S & F In Repairs, 15Mm Bore, Pvc Connection Pipe 600Mm Long With Ptmt Nuts At Both Ends Complete All As Specified And Directed. Make: Prayag Cat No. 324-Hk Or Equivelant Of Make As Per List Of Manufacturer 64 S&F In Repair Pvc Waste Pipe Of Bore 32 Mm And 900Mm Longto Whb All As Specified Complete All As Specified And Directed.Make: Prayag Cat No.3271 Or Equivelant Of Make As Per List Of ManufacturerS 65 S & F In Repair Soap Dish Holder, Fixed In Walls With Plugs & Chromium Plated Brass Screws Complete All As Specified And Directed.Make: Prayag Cat No. Ba-15S Or Equivelant Model Of Make As Per List Of Manufacturer Mentioned In Ps. 66 S & F In Repairs, Towel Ring Of Brass Chromium Plated Fixed To Wall And Including Chromium Plated Brass Screws And Wooden / Plastic Cleats Etc Complete All As Specified And Directed. Make: Prayag Cat No. Ba-11S Or Equivelant Model Of Make As Per List Of Manufacturer Mentioned In Ps. 67 S & F In Repairs, Single Towel Rail 600Mm Long, Stainless Steel With Brackets, Fixed Chromium Plated Brass Screws And Wooden / Plastic Cleats Etc Complete All As Specified And Directed.Make: Prayag Cat No.Ba-10S Or Equivelant Of Make As Per List Of ManufacturerS As Metioned In Ps 68 Suppy And Fixing In Repair Looking Mirror With Frame Of Size600 Mm X 450Mm X 6 Mm Of Selected Quality Belgium Glass And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed. Make: Prayag Cat No. Blm-01F Or Equivelant Of Make As Per List Of ManufacturerS 69 Taking Down Chowkats Or Frames With Shutters Not Exceeding 1.5 Sq.M Each ( Without Taking Off Shutters From The Frames ) Complete All As Specified And Directed. 70 Taking Down Chowkats Or Frames With Shutters Exceeding 1.5 Sq. M Each N Exc 4 Sqm ( Without Taking Off Shutters From The Frames ) Complete All As Specified And Directed 71 S & F Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door / Window / Ceosetory Windows & Other Frames / Chowkhat Of Size 65X125 Mm Comprising Of Virgin Pvc Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg / Cum, Screw Withdrawal Strength Of 2200 N ( Face ) & 1100 N ( Edge ) , Minimum Compressive Strength Of 58 N / Mm2, Modules Of Elasticity 900 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With Ms Hold Fast / Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge. ( M.S. Hold Fast / Lugs Or Ss Dash Fasteners Shall Be Paid For Separately ) . ( Note: For Wpc Solid Door / Window Frames, Minus 5Mm Tolerance In Dimension I.E. Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensionson Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made. All As Per Direction Of Engineer-In-Charge. ( Note: Stainless Steel Butt Hinges With S S Screws Shall Be Paid Separately ) 72 S & F 30Mm Thick Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Comprising Of Virgin Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg / Cum And Screw Withdrawal Strength Of 1800 N ( Face ) & 900 N ( Edge ) , Minimum Compressive Trength 50 N / Mm2, Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Hreaded Star Headed Counter Sunk S.S Screws, All As Per Direction Of Engineer-In-Charge. ( Note: Stainless Steel Butt Hinges With S S Screws Shall Be Paid Separately ) Complete All As Specified And Directed. 73 S & F Pvc Solid Ventilators With Frame Size 55X47mm With Wall Thickness 5Mm Made Out Of Extruded Pvc Sheet, Mitre Cut At Corners And Jointed With 2 Nos, 150Mm Long Brackets Of 15X15mm Ms Square Tube, The Two Vetted Profiles Are To Be Reinforced With 19X19mm Ms Square Tube, 50% Of Bottom Portion Shall Be Fixed With 4Mm Thick Pin Headed Glass And Balance 50% Of Top Portion Shall Be Fixed With 4Mm Thick Pin Headed Glass Lowers And Covered With 0.36Mm Dia Stainless Steel Wire Mesh At Top Portion Including Necessary Pvc Beading With Screw And 3 Nos 12Mm Dia Ms Guard Bars Fixed In Ventilator Frame Including Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Chrome Primer To Ms Guard Bars And Necessary Fixtures Complete All As Specified And As Directed. 74 S & F Powder Coated ( Minimum 50 Micron ) Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. ( Note : ( I ) Thickness Of Aluminium Section Shall Not Be Less Than 1.5 Mm ) . 75 S & F Powder Coated ( Minimum 50 Micron ) Anodised Aluminium Window And Ventilator Shutters, Sliding Type Without Sash Bar, Aluminium Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws Etc. And Anodised Aluminium Fittings Such As Peg Stay 150Mm Long ( 01 No ) , Hinge Type B-21, 100Mm Long ( 02 Nos ) And Suitable Size Of Handle Complete All As Specified And Directed. 76 S&F Anodised Aluminium Grill ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15 ) Of Approved Design / Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass / Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, Complete All As Specified And Directed. 77 S & F 35 Mm Thick, Flush Shutters, Solid Core Construction, With Particle Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified And Directed. 78 S&F 4 Mm Thick Veneered Decorative Plywood, Grade 1 ( With Bwr Resin ) With Decorative Face Veneers On One Face; Fixed With Screws To Timber Frame Work Complete All As Specified And Directed. 79 S & F 35 Mm Thick, Factory Made, Glazed / Skeleton Shutters With First Class Hard Wood, Open Rebated And Prepared To Receive Glass, Gauze, Etc ( Without Sash Bars ) Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut Mitred Beads For Securing Glass, Etc Complete As Specified And Directed . Sizes Of Members Of Shutters As Specified In Ssr Part I Complete All As Specified And Directed 80 S & F 35 Mm Thick, 2Nd Class Hardwood, Factory Made, Plain Framed, Panelled Shutter ( Two Panel ) With Lock Rail And Panel Of 9 Mm B.W.P. Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is : 1003 ( Part I ) , Kiln Seasoned And Chemically Pressure Treated Complete All As Specified And Directed. 81 S & F Well Seasoned 2Nd Class Hard Wood Plain, Solid, Straight Chowkat And Frames, Wrought, Framed, Rebated On The Solid Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And As Directed. 82 M & L For Plain Cement Concrete 1:3:6, Type C-1 ( Using 20Mm Graded Stone Aggregate ) For Embedding Holdfast, In Lintels Upto 1.5M Clear Span, Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Asdirected Complete All As Specified And Directed. 83 M & L For Mild Steel Bands, Straps, Supports Or Stays For Rainwater, Ventilating Pipes, Including Bolts, If Required: Hooks ( Stay ) , Heavy, For Large Gates; Hook And Pintle Hinges: Large Hasps And Staples; Chains; Hand Made Sliding Bolts; Clamps; Hold Fasts; Wall Ties; Hooks For Hanging Fans; Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters; Knee Piece Inserts; Two Way And Three Way Straps, Plate Washers And Similar Small Articles Conforming To Fe-290 Gde-E-165 Complete All As Specified And Directed. 84 S & F Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40 Mm And Fixed With Stainless Steel Wire Staples Complete All As Specified And Directed. 85 S & F Aluminium Alloy Anodised Sliding Door Bolt With Hasp & Staple ( Bolt Type ) And Fixing Clipes Of Sheet, Cast Or Extruded Sections And Fixing Bolts Of Extruded Sectionsor Cast Aluminium Alloy, Length Of Bolt Of 300 Mm Complete All As Specified And Directed. 86 S&F 150 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And Directed 87 S & F 125 Mm Long, Stainless Steel Butt Hinges Fixed With Stainless Steel Hinge Pin Etc Complete All As Specified And Directed. 88 S & F 100 Mm Long, Stainless Steel Butt Hinges Fixed With Stainless Steel Hinge Pin Etc Complete All As Specified And Directed. 89 S & F 150 Mm Size, Extruded Aluminium Alloy Handles, Fabricated Type, Anodised Complete All As Specified And Directed. 90 S & F 100 Mm Size, Extruded Aluminium Alloy Handles, Fabricated Type, Anodised Complete All As Specified And Directed. 91 M & L For Preparation Of New Or Previously Untreated Wood And Wood Based Surfaces Of Any Description, Not Otherwise Described, Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint ( 1St Grade Quality ) Over A Coat Of Pink Primer Complete All As Specified And Directed. 92 S & F In Repair Floor Door Stopper Of Aluminium Alloy Body And Tongue, Anodised, 150 Mm Overall Length Of Cover Plate With Hard Drawn Steel Spring, Fixed In Floorcomplete All As Specified And Directed. 93 S & F In Repair 25 Mm Dia, Stainless Steel, Fancy Curtain Rod, Heavy Duty, Including Stainless Steel Bracket Of Superior Quality For Each Opening / Door / Window Etc Complete All As Specified And Directed. 94 Taking Down Cement Plaster On Brick Or Stone Walls, Etc., Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. And Removing Rubbish To A Distance Not Exceeding 1.5 Km But Not Exceeding 5.00 Km Complete All As Specified And Directed. 95 M & L For Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6 And Finished The Surfaces Even And Fair Without Using Extra Cement Complete All As Specified And Directed. 96 M & L For15 Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfacesandfinishing The Surface Even And Fair Without Using Extra Cement By Mixing Wpc @3% Of Weight Of Cement ( Wpc Shall Be Paid Under Saparate Item ) Complete All As Specified And Directed. 97 M&L For5mm Thickrendering In Cm 1:3 On Any Faces Of Concrete Surfaces Finished Fair And Even Without Using Extra Cement In Ceiling / Chajja Etc Completeall As Specified And As Directed. 98 M & L Forpost Construction Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron.Complete All As Specified And Directed. 99 M & L For Post Construction Antitermite Treatment Treatment Of Soil Under Existing Floors Using Emulsion @ One Litre Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 ( 1 Cement: 2 Coarse Sand ) To Match The Existing Floors Complete All As Specified And Directed. 100 M & L For Post Construction Antitermite Treatment By Treating At Points Of Contact Of Wood Work By Chemical Emulsion ( In Oil Or Kerosene Based Solution ) @ 0.5 Litre / Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All As Specified And Directed. 101 Supply, Hoistedand Fixingin Position 2000 Ltrs Capacity Rotational Moulded Polyethylene Water Storage Tank, Double Layer Construction, Isi Mark ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position With And Including 20 Mm Dia Gi Pipe Medium Grade Washout Pipe 450 Mm Long With Plug And 20 Mm Dia Gi Pipe Medium Grade Overflow Pipe 600 Mm Long With Fittings Including 25 Mm Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed ( Minium Weight 15 Mm - 210 Gms ) Complete All As Specified & Directed. 102 Complete Removing The Plants From The Surfaces Of The Building With Complete Roots, Applying Recommended Chemical To Prevent Further Growth As Directed, Making Good The Disturbed Surface With Cement Mortar 1:3 And Applying The Same Surface Finish Of The Existing Surface And Finished To Match With The Surrounding Surfaces Including Removal Of Debris Etc., Out Side The Premises Complete All As Requiredcomplete All As Specified And As Directed. 103 M & L For Preparing Newly Plastered Surfaces Of Walls, Etc And Applying Three Coats Of White Wash Complete All As Specified And Directed. 104 M & L For Preparing Old Plastered Surfaces Of Walls, Etc And Applying One Coat Of White Wash Complete All As Specified And Directed. 105 M&L For Preparation Of Old Decorated Surface Of Wall By Complete Removal Of Existing Treatment, Washing, Rubbing, Stopping Etc And Applyingtwo Coats Of Weather Proof Exterior Acrylic Emulsion Paint Havingdart Pick Up Resistant, Silicon Enhanced, Uv Resistant And Pu Enhanced Propertyover A Coat Of Alkali Resistant Primer Including Applying One Or More Coat Of Wall Care Putty To A Smooth Surface Including Making Good Any Undulations On The Surfaces Including All Necessary Scaffolding Complete All As Specified And As Directed.Note :- Painting Work Shall Be Carried Out Acoording To Smart Painting Procedure Mentioned In Ps 106 M&L For Preparation Of New Platered Surface Of Wall And Applying Two Coats Of Oil Bound Distemperover A Coat Ofprimer Including Applying One Or More Coat Of Wall Care Putty To A Smooth Surface Including Making Good Any Undulations On The Surfacescomplete All As Specified And As Directed.Note :- Painting Work Shall Be Carried Out Acoording To Smart Painting Procedure Mentioned In Ps 107 M&L For Preparation Of Old Decorated Surface By Complete Removal Of Existing Treatment, Washing, Rubbing, Stopping Etc And Applyingtwo Coats Of Oil Bound Distemper Over A Coat Ofprimer Including Applying One Or More Coat Of Wall Care Putty To A Smooth Surface Including Making Good Any Undulations On The Surfacescomplete All As Specified And As Directed.Note :- Painting Work Shall Be Carried Out Acoording To Smart Painting Procedure Mentioned In Ps 108 M&L For Preparation Of New Platered Surface Of Wall And Applying Two Coats Of Weather Proof Exterior Acrylic Emulsion Paint Havingdart Pick Up Resistant, Silicon Enhanced, Uv Resistant And Pu Enhanced Propertyover A Coat Of Alkali Resistant Primer Including Applying One Or More Coat Of Wall Care Putty To A Smooth Surface Including Making Good Any Undulations On The Surfacesincluding All Necessary Scaffolding, Complete All As Specified And Directed.Note :-Painting Work Shall Be Carried Out Acoording To Smart Painting Procedure Mentioned In Ps 109 M&L For Preparation Of Old Painted Wooden Surfaces Of Any Description Exc 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In-Charge. 110 M & L For Writing Letters Or Figures ( Block , Roman, Italicor Indian ) N. Exc 30 Cm Height With Synthetic Enamel Paint Complete All As Specified And Directed. 111 S & F In Repairs, Acrylic Pvc Bathroom Cabinet Of Size 350 X 450X100 Mm With Openable Shutter Fixed With Looking Mirror Of Selected Quality And With Suitable Shelves In Side The Cabinet Of Superior Quality As Approved. Make: Prayag Cat No. 551 Or Equivelant Of Make As Per ManufacturerS List 112 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Etc Complete All As Specified And Directed. 113 S & F 18 / 19 Mm Thick, Plywood, Grade Bwp, Type Bb, Fixed With Screwsto Timber Frame Work, Etc Complete All As Specified And Directed. 114 S & F 0.90 Mm Thick, Decorative Laminate Type 1 Of Surface Finish, Colour And Pattern As Approved, Fixed With Approved Adhesive As Per ManufacturerS Instructions Complete All As Specified And Directed. 115 M&L For 2 Nd Class Hardwood Plain Fillets Square, Rectangular Or Triangular In Section, Clean Sawn Bullnosed, Splayed, Chamfered Or Rounded On One Edge Or Face Sectional Area N.Exe 3 Sq.Cm Complete All As Specified And Directed. 116 S&F 75 Mm Longstainless Steel Butt Hinges Extruted Section Complete All As Specified And Directed. 117 S & Fcontinuous ( Piano ) Hinges, Mild Steel, Bright Finish Or Electro Galvanised, 40Mm Width Of Flape When Open Complete All As Specified And Directed. 118 S&F Brass Hat And Coat Hooks, Solid Body, 175Mm To 250 Mm Long Complete All As Specified And Directed. 119 S & F 75 Mm Size, 4 Lever, Brass Locks With Duplicate Key For Cupboard, Complete All As Specified And Directed. 120 S & F Magnetic Catch With Striking Plate, 40Mm Size Superior Quality Complete All As Specified And Directed. 121 S & F 300 Mm Long, Mild Steel, Ordinary Rat Tail Rod Pattern Springs Incuding Roller And Roller Plate Complete All As Specifed And Directed. 122 S & F 82Mm Size, Night Latch With 7 Levers With Two Keys, Brass Body, Polished Bright; Vertical Type With Brass Knob Or Lever Handle And Fixedcomplete All As Specified And Directed. 123 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Etc Except Light Fitting. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surfaces Of Walls, Floors, Etc. Complete All As Specified And Directed. 124 Taking Down Unserviceable Main Switches, Dbs, Bus Bars Chambers Any Capacityincluding All Fittings And Fixtures Such As Mcbs, Isolator, Etc And Removing From Site Complete All As Specified Anddirected. 125 Taking Down Unserviceable Sub-Main Wiring ( Any Numbers Of Cable ) Withrigid Pvc / Steelconduits / Pvc Casing-Caping Including Cutting Chases For Conduits And Making Good Disturbed Surfaces Complete All As Specified And Directed. 126 M & L For Conceledpoint Wiring With Two Runs Of Single Core 1.5 Sq.Mm. ( Nominal Area ) Pvc Insulated Unsheathed Multistranded Copper Conductor Cable Frlsh ( Isi Marked ) Drawn Through And Including Non Metallic Pvc Conduit 20 Mm Bore ( Minimum ) Medium Grade ( Isi Marked ) Concealed Type Includingmetal Gi Boxes Of Suitable Module Including Modular White Cover Plate Of Suitable Module For Fixing Modular Type Switches, Sockets, Regulators Etc. Including Provision Of Multistranded 1.5 Sq.Mm Copper Conductorcable Frlsh [ Isi Marked ] As Earth Wire Connected To Common Earth Dolly And Earth In Distribution Board Complete All As Specified And As Directed, For One Light / Exhaust Fan / Fan Point / Call Bellcontrolled By One Way Switch. ( Note.: ( I ) The Rate Quoted Is Deemed To Include Making Good The Disturbed Sufaces And To Match The Adjoining Surface. ( Ii ) The Quoted Rate Is Deemed To Include Cutting Chases For Concealed Wiring Including Making Good The Same As Per The Existing One ) 127 All As Per Item No. 126 Above But For One 3 / 5 Pin Socket Outlet 6 Amps On Independent Board Complete Ditto 128 All As Per Item No. 09 Above But For One 3 / 5 Pin Socket Outlet 6 Amps Pointon Same Boardcomplete Ditto 129 All As Per Item No. 09 Here In Before But For One 15 Amps Power Point On The Independent Board With Two Runs Of Pvc Insulated And Unsheathed Copper Conductor Cable Of Size 2.5 Sqmm Multistrandedfrlsh ( Isi Marked ) And 2.5 Sqmm Pvc Insulated Unsheathed Solid Copper Conductor Cablefrlsh ( Isi Marked ) As Earth Lead Complete Ditto 130 S & F Switch Modular Single Pole One Way 6 Amp 240 Volts, 1 Module Complete All As Specified And As Directed. 131 S & F Modular Socket Outlet6a, 2 / 3 Pin Combined, 2 Module, Ac 230V, 50Hz Complete All As Specified And As Directed. 132 S & F Modular Socket Outlet6a / 16A, 2 / 3 Pin Combined, 2 Module, Ac 230V, 50Hz Complete All As Specified And As Directed. 133 S & F Switch Modular Single Pole One Way 16 Amp 240 Volts, 1 Module Complete All As Specified And As Directed. 134 S & F Steped Type Modular Fan Regulator , 100 / 120 W 2 Module Complete All As Specified And As Directed. 135 S & F Ceiling Rose, 65 X 50Mm Two To Three Terminals, Pvc / Polycarbonate, Insolated Body Complete All As Specified And Directed. 136 Supply And Fixing Of Led Surface Mounting General Purpose Led Battens In Extruded Aluminium Housingtube Light Fitting1x 20Watt With Led Lamp , Driver Including Connecting Upthree Core1.00Sq. Mm Copper Conductor Flexible Wire / Cable Complete All As Specified.Make : Model Nolumilineplusneobs20wled830spcssind Of Havells Or Equivalent Model Of Make List As Given In Ps As Approved By Ge. 137 Supply And Fixing Of Led Surface Mounting General Purpose Led Battens In Extruded Aluminium Housingtube Light Fitting1x 10Watt With Led Lamp , Driver Including Connecting Upthree Core1.00Sq. Mm Copper Conductor Flexible Wire / Cable Complete All As Specified.Make : Model Nolumilineplusbs10wled830spcssind Of Havells Or Equivalent Model Of Make List As Given In Ps As Approved By Ge. 138 S & F In Repairs Lamp Holder, Pvc / Polycarbonate Type With Backplate Suitable For Batten Fitting Complete All As Specified And As Directed. 139 Supply And Fixing Led Street Light Fitting 35 Watt 230V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Triple Optics Complete With Ip 66 Protection With And Including 1.5 Sqmm Weather Proof 3 Core Frlh Grade Copper Conductor And 32 Mm Dia ( Or Higher Size As Per Manufacturers Recommendation ) Light Grade Gi Pipe ( Bend To Shape Or As Per Manufacturers Recommendation ) Bracket 1.5 Mtr Longcomplete With Ms Flat Iron Clamp ( Clamps Shall Be 40 X 5 Mm Ms Flat ) Nuts, Bolts & Washers Including Painting The Clamps With Two Coat Of Aluminium Paint Over A Coat Of Red Oxide Primerand Including Taking Up Old Light Fitting Complete All As Specified And As Directedcomplete All As Specified And Directedmake:- Havells Cat No Endurasundownsl35wled765pasybopc Or Its Equivalent Make Of Philips / Cg 140 S & Fled Outdoor Flood Light Fittings, Min Ip 66 Rated, High Pressure Aluminium Die Cast Housing And Toughened Glass Cover, 100 Watt, Lumen = 10000, Luminous Afficacy = 110 Lum / Watt, Cct:Ww / Nw / Cw, Cri > 70 Ra, 4Kv Surge Protection With External Spd Of 10 Kv, With Open And Short Circuit Protections With All Accessories, Internally Prewired And Connecting Up With Twin Core Twisted Copper Conductor Cable Of Suitable Size Including Lamp Complete All As Specifiedand Directed. ( Make: Havells Cat No. Jetaleganzafls100wled757p60dtotg Or Equivelant Of Make As Per List Of Manufacturer ) 141 S & F Distribution Board, Spn 8 Way, 240V, Double Door With Ip 43 Protection Ik 09 Complete All As Specified And As Directed. ( Make: HavellS Cat Part No. Dhdpshodrw08 Or Equivalent Make As Per List Of ManufacturerS Mentioned In Ps ) 142 Supply, Fixing, Commissioning And Testing Mcb Spn 6-32A Amps, 240 Volts, 10Ka, C Curve Complete All As Specified And As Directed ( Make: HavellS Cat Part No. Dhmgcsnf006-032 Or Equivalent Make As Per List Of ManufacturerS Mentioned In Ps ) 143 Supply, Fixing, Commissioning And Testing In Repairs Mcb Sp 6 To 32 Amps, 240 Volts, 10Ka, C Curve, Complete All As Specified And As Directed ( Make: HavellS Cat Part No. Dhmgcspf006-032 Or Equivalent Make As Per List Of ManufacturerS Mentioned In Ps ) 144 S & F Distribution Board, Tpn 4 Way, 415V, Double Door With Ip 43Protection, Ik 09 Complete All As Specified And As Directed. ( Make: HavellS Cat Part No. Dhdnthcdrw04 Or Equivalent Make As Per List Of ManufacturerS Mentioned In Ps ) 145 Supply, Fixing, Commissioning And Testing In Repairs Mcb Four Pole 63 Amps, 240 / 415 Volts, 10Ka, C Curve Complete All As Specified And As Directed ( Make: HavellS Cat Part No. Dhmgcfpf063 Or Equivalent Make As Per List Of ManufacturerS Mentioned In Ps ) 146 M & L For Sub Main Wiring With 2 Runs Of Single Core 2.5 Sqmm [ For Phase & Neutral ] Pvc Insulated, Unseathed, Multi Stranded Frlsh ( Isi Marked ) Copper Cable Drawn Through And Including Concealed Pvc Conduit Of Suitable Size ( Medium Grade ) With All Conduit Accesories And Fittings Along With 1 Run Of Single Core 2.5 Sqmm Pvc Insulated, Unseathed , Multi Stranded Frls ( Isi Marked ) Copper Cableas Earth Continuity Conductorcomplete All As Specified And As Directed. ( Note :- ( I ) Two Runs Of 2.5 Sqmm And One Runs Of 2.5 Sqmm Cable As Earth Wire And One Run Of Conduitshall Be Measured As One Length, ( Ii ) The Quoted Rate Is Deemed To Include Cutting Chases For Concealed Wiring Including Making Good The Same As Per The Existing One ) 147 M & L For Sub Main Wiring With 2 Runs Of Single Core 4 Sqmm [ For Phase & Neutral ] Pvc Insulated, Unseathed, Multi Stranded Frlsh ( Isi Marked ) Copper Cable Drawn Through And Including Concealed Pvc Conduit Of Suitable Size ( Medium Grade ) With All Conduit Accesories And Fittings Along With 1 Run Of Single Core 4 Sqmm Pvc Insulated, Unseathed, Multi Stranded Frlsh ( Isi Marked ) Copper Cableas Earth Continuity Conductorcomplete All As Specified And As Directed. ( Note :- ( I ) Two Runs Of 4 Sqmm And One Runs Of 4 Sqmm Cable As Earth Wire And One Run Of Conduitshall Be Measured As One Length, ( Ii ) The Quoted Rate Is Deemed To Include Cutting Chases For Concealed Wiring Including Making Good The Same As Per The Existing One ) 148 M & L For 40 Mm Bore, Steel Tubes, Galvanised, Light Grade With All Fittings, Laid In Floor / Road Crossing / Drain / Walls And Ceilings Or Laid In Floors Complete All As Specified And Directed. 149 Taking Down Ceiling Fan / Exhaust Fan Of Any Sweep With All Fittings, Sealing Cable End, Dismantling Blades And Removing Fan And Blades To Mes Store Yard Complete All As Specified And Directed. 150 Fixing / Hanging Only Ceiling Fan / Exhaust Fan Of Any Size / Sweep / Make Including Preparation Of Old Painted Surfaces Of Ceiling Fan Of Any Size / Sweep / Make, Cleaning All Dust Etc And Painting With One Coat Of Synthetic Enamel ( 1St Grade Quality White ) Paint By Spraying Including Filling Cavities With Fillerand Marking Same Mes No. With Parmanent Marker, Refixing The Blades Connecting Up Etc Complete All As Directed. 151 Supply, Fix, Installation And Commissioning Bldc Ceiling Fan Of Less Noise, Silent Operation, Light Colour, Conforming To Is-374-2019, 1200 Mm Sweep, 230 Volts, Bee 5 Star Rating Including All Accessories Such As Down Rod Etc And Connecting Up With 1.5 Sqmm, Pvc Insulated, Multistranded Copper Conductor Cables From Ceiling Rose To Fan Complete All As Specified And Directed. ( Note: Ceiling Fan Should Have Minimum 3 Years ManufacturerS Warranty ) Make : Usha / HavellS / Bajaj / Cg 152 S & F Exhaust Fan, 300 Mm Sweep, Heavy Duty, Metal Body 1400 Rpm, Ac, Single Phase, Complete With All Accessories And Louver And Electric Connection Including Making Necessary Holes In Wallscomplete All As Specified And Directed Make : Havells, Model : Ventil Air Ds Or Equivelant Of Make R Equivalent Make As Per List Of ManufacturerS Mentioned In Ps 153 S & F In Repairs Stationary Louvers Suitable For Exhaust Fan Of 300Mm Sweep Made Out Of Powder Coated Aluminium Anodised Sheet Of Min 1Mm Thick With Non Removable Blades Fixed Permanantly At 45 Degree Angle For Protection From Rain Including Aluminium Wire Mesh Of Suitable Size For Bird Control Complete All As Per The Existing Specification And As Directed. ( Note: Louver Has To Fixed Upto Sixty Metre Height Multistoried Building. The Unit Quoted Rate Shall Deemed To Be Inclusive Of Necessary Scafolding And Safety Measure For Fixing Of Louver Upto Sixty Metre Height. No Extra Claim On This Account Shall Be Entertained Later On ) 154 S & F 25 Watt, 230 Volts Ac Post Top Lantern, Outdoor Type With Decorative Post Top For 360 Degree Indirect Light, Ip 65 Protection With Impact And Corrosion Reisitant Comp [ Lete With Driver And Lamp, Fixing Accessories And Connecting Up With Suitable Copper Conductor Complete All As Specifiedand Directed.Make: HavellS Cat No. Coralpt25wled830ssymtopc Or Equivelant Of Make As Per List Of Manufacturer 155 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Meter Deep Below Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, Connected To Galvanized Steel Earth Lead Wire4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel, All As Shown In Electrical Plate No 3 Of Ssr Part - I, Including Necessary Excavation And Earth Work, P.C.C ( 1:3:6 ) Type C-I With 50 Mm Thick Pre-Cast R.C.C. ( 1:2:4 ) Type B-I Cover Slab ( Reinforced With 8 Mm Dia Deformed Bar @ 10 Cm C / C Both Ways And Suitable Handle Of 12 Mm Dia Round Bar ) , Including Providing Charcoal Or Coke And Common Salt In Alternate Layers Of 15 Cm Compacted Thickness All Around The Earth Electrode, With Funnel And 20 Mm Bore Galvanized Iron Watering Pipe ( Light Grade ) , Wire Mesh, Aluminium Lugs, Complete In All Respect, Gi Earth Wire Protected By 15 Mm Bore ( Medium Grade ) Galvanized Iron Pipe And Other End Connected With Main Switch Board Or Earthing Test Point As Directed, Including Necessary Earth Work And Disposal Of Spoil To A Distance Not Exceeding 50 Metre And Necessarytesting On Completion Inclduing Taking Down Old One Complete All As Specified And As Directed By The Engineer-In-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-05-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 43 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail