| 1 | Supply, laying, jointing and testing of XLPE under groundinsulated, armoured, heavy duty LT 1100 volts 16 Sqmm 4 core grade cable with aluminium conductor ISI marked, laid in trenches/pipes, fixed topoles/walls with suitable saddle & glands with and incl taking out the old burnt out cables complete all as specified and directed.(Note - Excavation, earthwork, sand cushioning , protection pipeand brick protection shall be measured andpaid for separately ) |
| 2 | Description all as per item No 1 above but of size 4 core 25 Sqmm . |
| 3 | Excavationintrenchesnotexc 1.5 m wideandnotexc1.5 m indepth fortakingout orlaying ofcable in soft/loose soil andgettingout competeallasspecifiedanddirected. |
| 4 | Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cm complete allasspecifiedanddirected. |
| 5 | Removal of surplus soil to a distance not exceeding50m where directed at a level not exc. 1.5M above the starting point complete allasspecifiedanddirected |
| 6 | Sand cushioning to underground cable withclean drysand locally available 8cm thick before laying the cable and 15cm above the cable,stretchingand testing of cable lcomplete allasspecifiedanddirected. Note : For payment purpose , punned thickness shall be measured and paid. |
| 7 | Brick protection with brickwell burntlocallyavailablesubclass \"B\" laid over sand cushioningtocableintrenches withwidthofbrickparalleltothelengthofcable complete allasspecifiedanddirected. |
| 8 | Supply & fixing in replacement Cable junction Box/distribution Board IP 65 with metric knockouts for cable entry of size 10 to 25 sq mm x 2 core including fastening clamp with LT pole, box size : 295 x 195 x 100 mm (or nearest higher size)hinged cover with locking arrangements including with terminals TPNstripwith 01 No MCB SP 6A complete allasspecifiedanddirected. |
| 9 | GI tubelightgrade galvanisedwithallfittingsfor cable protection50mmbore including fixed with poles complete allasspecifiedanddirected. |
| 10 | Supply & fixing in replacement 100 A 4 pole MCCB, 16KA ,415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete all complete as specified and directed. |
| 11 | Supply and fixing in replacement on load change over switch in sheet metal enclosure of capacity 4P 100 Amps, complete all as specified and directed. |
| 12 | GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.20 Metre long bent to shape as per specified for fixing Street Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe bracket with clamps complete all as specified and as directed. |
| 13 | Supply and fixing in replacement PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 1.5 sqmm 2 corecomplete all as specified and directed. |
| 14 | Supply and fixing in replacementLED ?ood light fitting of 120 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection complete all as specified and directed . |
| 15 | Description all as per Ser Item No.14 here-in-before but of 210 Watts |
| 16 | Supply and fixing in replacement LED street light fitting 45 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket complete all as specified and directed. |
| 17 | Description all as per Ser Item No.16 here-in-before but of 60 Watts |
| 18 | Supply and fixing in replacement LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection20 watts with high efficiency long life LEDs In-built replaceable electronic driver complete fixing on existing bracket complete all as specified and directed. |
| 19 | Supply and fixing in replacement inclerrection of steel tubuler swage poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc including painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and interally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle complete all as specified and directed. |
| 20 | M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from groundlevel will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed. |
| 21 | Material & labour for PCC 1:4:8 type D2 using 40mm stone aggregate for pole foundation complete all as specified and directed. |
| 22 | Material & labour for PCC 1:3:6 type C-1 using 20mm graded stone aggregate including use and waste of form work for pole coping / any description complete all as specified and directed. |
| 23 | M&L for opening the unserviceable/burnt ceiling fan 1200/1400 mm sweep and cutting of old burnt copper windingand rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed(NOTE:- Taking down/dismantling of ceiling fan and refixing after repair shall deemed to be include in this unit rate.) |
| 24 | Supply and fixing in replacement of ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed by engr-In-Charge. Make:- SKF/ NBC |
| 25 | Supply and fixing in replacement of gun metal bushes of suitable size for ceiling fan incl necessary mechanical work, complete all as specified and directed by Engr-In-Charge. |
| 26 | Supply and fixing in replacement of flexible cable, three core 0.5 SqmmPVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. |
| 27 | Supply and fixing in replacement capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 28 | Supply and fixing in replacement of ceiling fan blade set of three, heavy duty suitable for 1200/1400mm sweep of as per existing make as direcetd. |
| 29 | Supply and fixing in replacement of PVC canopy for ceiling fan 1200/1400mm sweep complete for existing various makes/model of fan, complete all as specified and directed by Engr-in-Charge. |
| 30 | M&L in repair for opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed as specified and directed.(NOTE:- Taking down/dismantling of exhaust fan and refixing after repair shall deemed to be include in this unit rate.) |
| 31 | All as per srl item No. 30 here-in-before, but 300mm sweep -ditto- |
| 32 | Supply and fixing in replacement ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC |
| 33 | M&L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all asspecified and directed. |
| 34 | M&L for servicing of geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed. |
| 35 | Supply and fixing in replacement heating element for geyser of capacity 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:-Usha/ Bajaj/ Havells |
| 36 | Supply and fixing in replacement Heating element for geyser of capacity 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:-Usha/ Bajaj/ Havells |
| 37 | Supply and fixing in replacement thermostat for Geyser of capacity 25/35/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus |
| 38 | Supply and fixing in replacement geyser syphon assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, as per existing complete all as specified and directed |
| 39 | Description all as per item Srl No. 38 above butfor 35 Ltr capacity -ditto- |
| 40 | All as per item Srl No. 37 above butfor 50/100 Ltr capacity -ditto- |
| 41 | Supply and fixing in replacement rubber gasket for water heater storage type of any capacity and suitable as per the existing, complete all as specified and directed |
| 42 | Supply and fixing in replacement PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. |
| 43 | S & F in replacement sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified. |
| 44 | Supply and fixing in replacement of safety valve for geyser of 25/35/50 litre capacity, as per existing make complete all as specified and directed |
| 45 | Supply and fixing in replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 46 | Supply and fixing in replacement heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 47 | Supply and fixing in replacement copper inner tank of geyser capacity 15/25 litre and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed. |
| 48 | All as per item Srl No. 47 above butfor 35 Ltr capacity -ditto- |
| 49 | All as per item Srl No. 47 above butfor 50 Ltr capacity -ditto- |
| 50 | M&L for preparation of surface of Geyser of capacity 25/35/50 Ltr by scraping, removing old paint etc and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 51 | Supply and fixing in replacement of compressor fo refrigerator of 165 to 200 ltr capacity as per the existingcomplete all as specified and directed. |
| 52 | Supply and fixing in replacement of thermostatfor refrigerator of 165 to 200 ltr capacity. |
| 53 | Supply and fixing in replacement of thermal relay for refrigerator of 165 to 200 ltr capacity. |
| 54 | M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 165 to 200 ltr capacity all as specified and directed. |
| 55 | Supply and fixing in replacement of compressor fo refrigerator of 210 to 335 ltr capacity as per the existingcomplete all as specified and directed. |
| 56 | Supply and fixing in replacement of thermostatfor refrigerator of 210 to 335 litre capacity. |
| 57 | Supply and fixing in replacement of thermal relay for refrigerator of 210 to 335 litre capacity. |
| 58 | M&L charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 210 to 335 ltr capacity all as specified and directed. |
| 59 | Supply and fixing in replacement of compressor for deep freezer of 210 to 400 ltr capacity as per the existingcomplete all as specified and directed. |
| 60 | Supply and fixing in replacement of thermostatfor deep freezer of 210 to 335 litre capacity. |
| 61 | Supply and fixing in replacement of thermal relay for deep freezer of 210 to 335 litre capacity. |
| 62 | M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for deep freezer of 210 to 400 ltr capacity all as specified and directed. |
| 63 | M&L for disconnecting the electric supply from the mains, transporting the window/split type air conditioner capacity 1.5/2.0 ton from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed. |
| 64 | Taking out old burnt/unserviceable compressor from the air conditioner 1.5/2.0 ton capacity and supply and fixing new compressor as per the existing, re-fixing in position incl testing satisfactory working complete all as directed. |
| 65 | M&L for charging refrigerant gas R134A in 1.5/2.0 ton capacity window /Split type air conditioner complete including testing for satisfactory working after flushing out and cleaning the surface with nitrogen gas for checking the leakage, complete all as specified and directed. |
| 66 | Supply and fix in replacement blower motor suitable for 1.5/2.0 ton capacity air conditioner all as directed. |
| 67 | Supply and fix in replacement thermostat suitable for 1.5/2.0 ton capacity air conditioner all as directed. |
| 68 | Supply and fix in replacement of running condenser 36 Mfd, complete all as directed. |
| 69 | Supply and fix in replacement of starting condenser 100/120 Mfd, complete all as directed. |
| 70 | Supply and fix in replacement of relay suitable for 1.5/2.0 ton capacity air conditioner, complete all as directed. |
| 71 | Taking out unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED\"s etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC complete all directed. |
| 72 | Description all as per item Srl No. 71 above butforcapacity 0.25 to 1 KVA-ditto- |
| 73 | M&L for Dismantling the complete fuel injector pump of water heating plant of various capacity upto 2000 ltrs, transporting to trade workshop for repairs and complete servicing and refixing the same after satisfactory repairs, reinstallation, testing and commissioning complete, all as specified and directed. |
| 74 | Material and labour for calibration and complete repair of fuel injection pump of water heating plant of various capacity upto 2000 ltrs, on work bench for fine spray and machining work and refixing the same for satisfactory functioning, complete all as specified and directed. |
| 75 | Supply and fix in replacement nozzleof hot water plant as per existing size complete all as specified and directed. |
| 76 | Supply and fix in replacement pressure meter suitable for hot water generator as per existing size complete all as specified and directed. |
| 77 | Supply and fix in replacement fuel filter suitable for hot water generator as per existing sizecomplete all as specified and directed. |
| 78 | Supply and fix in replacement solenoid switch for hot water generator as per existing size complete all as specified and directed. |
| 79 | Supply and fix in replacement burner gasket suitable for hot water generator as per existing size complete all as specified and directed. |
| 80 | Supply and fix in replacement digital type electronictemprature gauge with thermostat control relay suitable for 2,00,000 K Cal/hr capacity hot water generator as per existing size and testing complete all as specified and directed. |
| 81 | Supply and fix in replacement indicator assembly, complete all as specified |
| 82 | Supply and fix in replacement bimetallic overload relay 4.0 - 6.5 Amps type ML complete all as specified |
| 83 | Supply and fix in replacement electromagnetic rod combined with positive/ negative terminals suitable for hot water generator of any capacity as per existing size and testing complete all as specified and directed. |
| 84 | Supply and fix in replacement photo censor suitable for hot water generator/plant as per existing size and make incl testing complete all as specified and directed. |
| 85 | Supply and fix in replacement high pressure diesel/fuel pipe with internal and outer threads suitable for hot water generator/plant as per existing size incl testing complete all as specified and directed. |
| 86 | M&L for dismantling fuel tank of water heating plant, servicing, decarboning, cleaning, removing ofof complete water plant and reassembling the same after cleaning properly by removing all deposited particles, dust, carbon etc, complete all as specified and directed. |
| 87 | M&L for disconnecting and taking out burnt hot water plant blower motor, transporting to workshop, dismantling carefully, cutting out burnt windings, cleaning the slots and rewinding with super enamelled copper winding wire of appropriate gauge & weight incl all insulating materials, varnishing, drying, heating etc and incl replacement of ball bearings as per existing, reassembling and refixing at original site and testing, complete all as specified and directed. |
| 88 | M&L for disconnecting existing defective 500L capacity Heating plant/ Haman from electric mains, water mains and fuel pump isolating the necked connections, removing from foundation by unscrewing the nut bolts etc, discouple from pump and motor, opening of Heating plant/Hamam and motor for inspection in presence of Engr-in-charge and to carry out major repairs transporting to workshop and back, re-assembling the Heating plant/ Hamam after repair, refixing in position reconnecting same as prior to removing from foundation including replacement of nuts, bolts, washers of suitable size, testing and commissioning complete all as specified and directed.Disconnecting the Heating plant and remove the SS inner and outer tank carefully, carry to trade workshop for necessory repairs such as :-(a) Cut the rust out parts of 500 Ltr capacity Heating plant/ Hamam.(b) Moulding of inner tank of 500 Ltr capacity Heating plant/ Hamam and welding work.(c) Moulding of outer tank of 500 Ltr capacity Heating plant/ Hamam and welding work.(d) Supply and filling in replacement of Glass wool between the inner and outer tank.(e) Supply and fixing in replacement upper and lower aluminium strap for suitable size.(f) Supply and fixing in replace ment of necessory quanty and size of nut,bolt and washer.(g) Supply and fixing in replacement of Base plate of 500 Ltr capacity Heating plant Hamam of existing size with GI plate of minimum 5 mm thick.(h) Supply and fixing in repair of water connection arrangement of water Heating plant/Hamam i.e, Nipple,socket, reducer socket and Gate valve/ ball valve etc.(j) Repair/ replacement of Top and bottom cover.(k) Other miscellanious Repairs.(l) Supply and eplacement of inner (Dollaky) Plates 5 mm thick.(m) Supply and replacement of Vertical MS tubes size of 50 mm. |
| 89 | BOQ Item No. 88 Contd....Note:- (i) Replacement of defecting parts is included in the Quated rate.(ii) major repairs are not possible at site, the Heating plant/ Hamam shall be shifted to Civil workshop, and cost of shifting to workshop and back to site included in the rates.Loc: 54 RVC - 01,ARO - 1 |