Tender For Provision Of 50 Ton Trailer Repair Shed At Hisar Mil Station. ; 1 Schedule A Part I ( Building Works ) Is Not Prepriced By Mes And Prepriced Rates Indicates 0.0 Under Column 5 Is Signified This Fact Only 2 Schedule A Part I ( Building Works ) Is Not Prepriced By Mes And Prepriced Rates Indicates 0.0 Under Column 5 Is Signified This Fact Onlym&L For Construction Of 50 Ton Trailer Repair Shed ( Pre Engineering Building ) Including Annexie ( Rcc Structure ) But Excluding Hardstanding / Apron Including Design, Drawings And Vetting Of Design As Per Ca Provisionscomplete All As Specified And As Shown On Drawings. 3 Lump Sum Price Worked Out By The Contractor For Internal Water SupplyAs Listed In Schedule ‘A’ Part- Ii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 4 Lump Sum Price Worked Out By The Contractor For Internal ElectrificationAs Listed In Schedule ‘A’ Part- Iii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 5 Lump Sum Price Worked Out By The Contractor For Road / Path / Culvert / HardstandingAs Listed In Schedule ‘A’ Part- Iv Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 6 Lump Sum Price Worked Out By The Contractor For Sewage DisposalAs Listed In Schedule ‘A’ Part- V Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 7 Lump Sum Price Worked Out By The Contractor For Area DrainageAs Listed In Schedule ‘A’ Part- Vi Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceof Prepriced By The Mes 8 Lump Sum Price Worked Out By The Contractor For Externalwater SupplyAs Listed In Schedule ‘A’ Part- Vii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 9 Lump Sum Price Worked Out By The Contractor For External ElectrificationAs Listed In Schedule ‘A’ Part-Viii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes B / F 10 Lump Sum Price Worked Out By The Contractor For ( Dg Set ) As Listed In Schedule ‘A’ Part- Ix Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Price Prepriced By The Mes 11 Lump Sum Price Worked Out By The Contractor For Summer AppliancesAs Listed In Schedule ‘A’ Part- Xrepresenting Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 12 Lump Sum Price Worked Out By The Contractor For Lightening ProtectionAs Listed In Schedule ‘A’ Part- Xirepresenting Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 13 Lump Sum Price Worked Out By The Contractor For Air CompressorAs Listed In Schedule ‘A’ Part- Xiirepresenting Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 14 Lump Sum Price Worked Out By The Contractor For Excavation&EarthworkAs Listed In Schedule ‘A’ Part-Xiii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Price Prepriced By The Mes 15 Sch A Part-Xiv ( Miscellaneous Items ) :-Notes: ( I ) This Schedule Is Not Pre-Priced By Mes And The Pre-Priced Rate Indicated As Rs 0.00 Under Column 5 Signifies This Fact Only. ( Ii ) Excavation And Earth Work Except For The Items Which Categorically Includes For Same Shall Be Measured And Paid Separately Under Sch A Part-Xiii ( Excavation & Earthworkschedule ) . 16 Inernal Electrification:-S&F Mcb, C Curve, Isi Marked , 10Ka, Integrated Lable Holder, Sliding Bottom Clamp, Improved Air Channels, Colour Coded On / Off Indication On Dolly, Biconnect Lower Terminals, Ip 20 Protected Terminals , Sliding Shutters , Conforming To Is 60898-1-2002 Of Under Mentioned Type And Rating And Fixing In DbS Complete Allas Specifed And Directed.Note ( I ) :- Dbs Shall Be Measured And Paid Seperately ( Ii ) :- Make Of The Mcb Shall Be The Same As That Of Db. 17 Sp 6-32Amp 18 Spn 32Amp 19 Tpn 40Amp 20 Tp 40Amp 21 Tp 32Amp 22 Tp 20Amp 23 Tp 16Amp 24 S&Fmccb 125 A, 25Ka , 4 Pole, Adjustable Thermal Magnetic Release, Ics = 100% Icu Complete All As Specified And As Directed. 25 S&F For Factory Madevtp&N6 Ways, Sheet Steel Distribution Boards, Double Door Type, Protection Class ( Ip-42 ) Suitable For Mounting Mcb, Dbs Conforming To Is-13032, Is-8623, Bs-5484 With Minimum 200 Amp Rating Copper Bus Bar. 26 Supply And Fix Factory Made Sheet Metal Triple Pole And Neutral Enclosure With Metal Clad With 3 Pin And Earth Plug With Socket Complete With One Mcb Tp 16 Amp, 415 Volts10 Ka Complete As Specified And Directed. 27 S&F Led Bulb Holder With Led Bulb 01X05 Watt Complete All As Specified And As Directed 28 Supply And Fix Wall Mounted Led Batten Fitting , 22 Watt Led 6000K, With Led Rod 1X 22 Watt, Extruded Aluminium Heat Sink Provided For Efficient Heat Dissipation & Integrated Electronic Driver Complete Including Connecting Up With 03 Core Flexible Copper Cable 23 / 0.0076 For Electric Connection For Fitting From Ceiling Rose Complete All As Specified And As Directed 29 Supply And Fix Wall Mounted Led Batten Fitting , 10 Watt Led 6000K, With Led Rod 1X 10 Watt, Extruded Aluminium Heat Sink Provided For Efficient Heat Dissipation & Integrated Electronic Driver Complete Including Connecting Up With 03 Core Flexible Copper Cable 23 / 0.0076 For Electric Connection For Fitting From Ceiling Rose Complete All As Specified And As Directed 30 Supply And Fix 45 Watt Led Security Light Fitting, 240 Watt Ac, 50 Hz Of New Generation Energy Saving & Environmental Friendly Long Life Versatile Pressure Die Cast Aluminium Ip 66 Roadway Luminair With High Power Leds As Light Source And Electronic Driver, Pre Wired, Complete With All Necessary Fittings And Fixed On Wall With 40Mm Dia Bend To 120 Degree In Shape Gi Pipe Light Grade Of Length 1.5 Mtr With Clamps, Nut & Bolts Etc. As Directed And Specified. 31 S&F 150 W Led High Bay Light Fitting, 240 Volts Ac, 50 Hz Of New Generation Energy Saving & Enviromental Friendly Long Life Versatile Pressure Die Cast Aluminium Ip 66, Lumen Efficacy >150 Im / W With View Angle 120 Degree To Ensure Better Uniformity Of Light Distributuion, Lm 79 Certified. Built, In Electronic Driver With Apfc, Lower Thd, Open Circuit Protection, Surge Voltage Protection Upto 10Kv With Built In Spc & Other Safety Test As Per Is 15885 Pre Wired, Complete With All Necessary Fittings And Fixed On Ceiling / Wall Complete All As Directed And Specified. 32 M&L, Earthing Complete With Galvanised Mild Steel Earth Electrode Plate 600 X 600 X 6 Mm Thick Buried Directly And Vertically In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metres Below Normal Ground Level, Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No 3 Of Mes Ssr Part-I Connected To Earthing Test Point All As Specified And Testing On Completion Including Provision Of Earth Wire Protected By Galvanised Iron 15 Mm Bore Medium Grade Pipe With All Fittings From The Earth Electrodefixed Along Pole With And Including 25 X 6Mm Flat Iron Clamp, Bolts, Nuts And Washers And Watering Pipe Shall Be 20 Mm Bore Gi Medium Gradefrom Top Of The Earth Electrode To Bottom Of The Earth Pit Of Dimensions 550 Mm X 550 Mm ( Outer ) And 300 Mm X 300 Mm ( Inner ) And 250 Mm Deep Including All Excavation And Earth Work In Any Type Of Soil And Removal Of Soil Upto 50 Metre, Pcc Pit With Pre-Cast Rcc Cover With Handle, Charcoal / Salt, Funnel , Ci Frame Etc Complete All As Specified And Directed.Note: ( I ) The Concrete Pit Shall Be Made In Pcc 1:2:4 Type B-O, Using 12.50 Mm Graded Crushed Stone Aggregate 40Mm Thick Precast Cover Slabof Rcc ( 1:2:4 ) , Type B-1, Using 20Mm Graded Crushed Stone Aggregate With Suitable Ms Handle In Lieu Of Ci Cover. Reinforcement In Cover Shall Be Of 8Mm Dia Tmt Bars Laid @150Mm C / C Both Ways. ( Ii ) Item Includes The Cost Ofgi Pipe For Protectionof Earthwire Including Earth Wire Up To 7.5 Metre. ( Iii ) Any Variation In Length Of Gi Protection Pipe And Earth Wire Below Orabove 7.5 Metreshall Be Adjusted Through Deviation. ( Iv ) Earth Electrode Shall Be Surrounded By Adequate Quantity Of Charcoal Dust And Salt To A Packed Thickness Of 15 Cm On All Sides.. 33 S&F For Factory Made, Sheet Steel Distribution Boards, Double Door Type, Protection Class ( Ip-42 ) Suitable For Mounting Mcb, Dbs Conforming To Is-13032, Is-8623, Bs-5484 With Minimum 100 Amp Rating Copper Bus Bar, For Followingcomplete All As Specified And Directed :-Notes : ( I ) Mcbs Shall Be Measured And Paid For Separately Under Relevant Items Of Schedule Of Work / Boq 34 Sp&N , 4 Ways 35 Sp&N , 12 Ways 36 Tp&N , 4 Ways 37 Supply And Fixing Ceiling Fans Complete With Blades, Down Rods, Electronic Regulator And Accessories, 230 V, 1200 Mm Sweep. Min Air Delivery 210 Cfm With Service Value 5.00 Bee Without Remotefive Star Rated With Brushless Direct Current Motor ( Bldc ) , Complete All As Specified And Directed. 38 M&L Sub Main Wiring Using Isi Marked 1.1Kv Grade Single Core Hr-Fr Flexible Cable Conforming To Is : 694-1990, Having Multi Drawn Thin Strands Of Elecctrolytic Copper Conductors And Insulation Conforming To Is : 5831-1984 , Type C, Hr 85 Degree C +Fr For Phase, Neutral And Earth Continuity Conductor Connecting To Earth Dolly , Drawn In And Including Not Less Than 32Mm Nb Upvc Medium Grade Surface / Recessed Conduits, Conforming To Is : 9537 Part 3, Colour Coded As Specified In Is :732-1989, Including Making Good Disturbed Surfaces Of Wall / Ceiling / Floor As Following Complete All As Specified And As Directed. ( Note ( I ) :- 03 Runs Of Phase Conductor, 01 Run Of Neutral Conductor, 01 Run Of Earth Continuity Conductor And 01 Run Of Concealed Conduit Shall Be Measured As One Length For Item No. 27.01 Below. ( Ii ) :- 01 Run Of Phase Conductor , 01 Run Of Neutral Conductorand 01 Run Of Earth Continuity Conductor And 01 Run Of Concealed Conduit Shall Be Measured As One Length For Item No. 27.02 & 27.03 Below 39 4 X 10 Sqmm+ 1 X 1.5 Sqmm Earth Wire + One Run Of Pvc Conduit 40 2 X 6 Sqmm+ 1 X 1.5 Sqmm Earth Wire + One Run Of Pvc Conduit 41 2 X 4 Sqmm+ 1 X 1.5 Sqmm Earth Wire + One Run Of Pvc Conduit 42 External Electrification :-Supply & Fixing Pole Mounted Cut Out Box Made Of Sheet Moulding Compound ( Smc ) , Weather Proof 230 X170 X105 Mm Outside Dimensions And 200 X 140 X 95 Mminside Dimensions, Confirming To Sintex Model No Gsjb-2014 Or Equivalent Make As Approvedwith One No. Rewireable Cut Outs 16 Amps 240 Volts, 02 Nos Insulated Aluminium Bus Bars On Porcelain Insulatorsand Neutral Link, Fixedon Pole In Replacement Including Making Incoming And Outgoing Cable Connections Completewith & Including Ms Clamps, Nut, Bolt& Washer. 43 Supplying , Installing , Testing And Commissioning , Factory Made And Tested ( Incl Proto Type Being Cpri Type Testcertified ) Lt Feeder Pillar Box , Outdoor Type , Cubical Type Weather Proof Fixed On And Including Ventilation And Louvers Arrangment. Pcc ( 1:3:6 ) Type C-1 As In Foundation Of Required / Suitable Size And As Directed At Site With Angle Iron Frame Of Size 40X40x5mm 3 Phase , Applying 4 Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer And Keeping Adequate Working Space Inside Of The Box ( Outer Width Of The Box Not Less That 45Cm And Gap Between Busbar Not More Than The One Inch ) And Double Door Be Provided With Proper Hinged And Sliding Door Handle Including Locking Arrangment With One No Pad Lock Of 65 Mm As Directed And Same Have The Following:- ( A ) Insulated Epoxy Painted High Conductivity Copper Bushbar 200 Amp ( Size 20Mm X10mm Thick ) 3 Phase And 100 Amp ( Size 10Mmx10mm Thick ) For Neutral Complete All As Spacified And Directed . ( B ) Digital Volmeter 1 To 500 Volts 95 Sqmm Type Flust Mounter With Selector Switch 3 Way - 01 No ( C ) Digital Amp Meter 1 To 200 Amp Cap With Ct 200 / 5 Amp With Selector Switch 3 Way - 1 No ( D ) Indicating Lamp Neon Type For Ryb - 01 Set. Incoming :-Mccb 4 Pole 415 Volts 100 Amp 25 Ka -01 No Outgoing :- ( A ) Mccb 4 Pole 415 Volts 63 Amp 16 Ka -02 Nos, ( B ) Mcb Tpn 4 Pole 415 Volts 40 Amp 16 Ka -02 Nos, ( C ) Mcb Sp 25 Amp 10 Ka -02 Nos ( B ) Time Switch Single Phase 20 Amps-01 Nonote :- All Incoming / Out Going Cables Shall Be Connected By Suitable Size Gland Plate / Glands And All Spreader Terminals Of Mccbs Should Be Connected With Bus Bars. 44 M&L, Earthingcomplete With Galvanised Mild Steel Earth Plate Electrode 600X600x6.3 Mm Thick Buried Directly In Ground Vertically ( Earth Pit Not Less Than 2.25 M Deep Below Normal Ground Level ) With The Top Edge Of The Earth Plate Electrode At A Depth Not Less Than 1.5M Below Normal Ground Level Connected To And Including Gi Earth Strip 32 X 6 Mm Bolted ( With Gi Nuts, Bolts & Check Nuts ) And Welding All Joints To Earth Plate Electrode At One End Connected To Mettalic Bodies Of Ht / Lt Equipment Etc At The Other End , Earth Strip Encased In And Including 50 Mm Bore Gi Medium Grade Pipe With All Fittings Including 25 X 6Mm Flat Iron Clamps, Nut Bolts And Washers And Including Providing Watering Pipe 20Mm Bore Gi Pipe Medium Grade From Bottom Of Concrete Pit To Top Of Earth Plate Electrode Complete All As Specified And Shown In Electrical Plate No 3 Of Mes Ssr Part-I And Connected To Earth Test Point Including Testing Complete.The Scope Of Workincludes Necessary Excavation And Earth Workin Any Type Of Soil, Removal Of Soil Upto 50 Metre, Pcc Pit With Precast Rcc Cover, Charcoal / Salt, Funnel, Ci Frame Etc Complete All As Specified And Directed. Note :Note:- ( I ) ( I ) The Concrete Pit Shall Be Of Pcc 1:3:6 Type C-1, 40 Mm Thick Pre-Cast Cover Slab Of Rcc 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate With Suitable Ms Handle Shall Be Providedin Lieu Of Cast Iron Cover Shown In Electrical Plate No.3 Of Mes Ssr Part-I. Reinforcement In Rcc Cover Shall Be Of 8Mm Dia Tmt Bars Laid @150Mm C / C Both Ways. ( Ii ) Item Includes The Cost Of Gi Pipe For Protection Of Gi Earth Strip Including Gi Earth Strip Up To 7.5 Meter. ( Iii ) Any Variation Of Of Gi Protection Pipe And Gi Earth Strip Below Or Above 7.5 M Shall Be Adjusted Through Deviation. ( Iv ) Earth Plate Electrode Shall Be Surrounded By Adequate Quantity Of Charcoal Dust And Salt To A Packed Thickness Of 15 Cm On All Sides 45 M&Lsub Class B Bricks ( Old Size ) As In Cable Protection Coverlaid Flat And Dry Abutting Each Other With Gap Between Adjacent Bricks Not Exc. 10Mm, Over Ug Cablecomplete All As Specified And Directed. 46 Supply And Fixing In Replacement Led Street Light Luminaries Of Cap 40 Watt, Spd -10Kv Internal With Lense, 240 Volt, , Pressure Die Cast Aluminium Housing Frame, Heat Resistant Toughtened Clear Glasswith Frame Complete With Accessories , Ip 66 Protection, Pre Wired Up To A Terminal Block And Mounting Attachment Of Gi Pipe 40 Mm Dia Light Grade Bend To 120 Degree In Shape For Fixig Of Light Of Length 1.2 Mtr Including Ms Clamps, Nuts, Bolts & Washer Duly Required With Pcc In Wall Complete All As Specified 47 Air Compressor :-Supply And Installation, Testing Andcommissioning Air Compressor Reciprocating Type Two Stage Compression , 32 Cfm Free Air Delivery , Working Pressure 12 Bar , 03 Cylinder Suction Filter Of 10 Micron With Silencer Body , Air Cooled , Oil Flooded Lubrication , Safety Valve Spring Loaded Type , Motor 10 Hp ( 7.5Kw ) , Dol Starter , Automatic Start Stop Control , Line Filter, Inter Cooling With Aluminium Finned Type , 3 Phase With 500 Litre Tank Capacity With All Connecting Accessories And Equipment Complete All As Specified And Directed And Also Recommended By Oem.Make :- Indo Air, Bac Compressor , Mark Compressor As Approved By Ge. 48 Supply And Fix Pneumatic Rubber Hose Pipe 15Mm Dia Complete With All Connecting Accessories Suitable For Connectiong Pneumatic Tools Complete All As Specified And As Directed. 49 Area Drainagem&L For Bricks, Fly Ash, Laid On Edge In Floors; Old Size Bricks Bedded And Jointed In Cement Mortar 1:6 And Pointed In Cm 1:3 Complete All As Specified And As Directed. 50 Lighting Protection:-M&L For Test Pointterminal Block Made Of Gun Metal Or Phosphorus Bronze Size 75X75x25mm Of 6Mm Thickness Or Copper Strip Of 32 X 6Mm, 100Mm Long Drilled And Screwed Including 04 Nos 8Mm Dia, 25 Mm Long Hexagonal Head Brass Screws Including Box Of Size 90X90x90mm Made Of 1.6Mm Ms Plain Sheet Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer And Screwed To Wall For Protection Of Test Point Complete All As Specified And Directed. 51 Air Circulator Fan :-Supply & Fix Air Circulator Fans 230 Volts Single Phase Oscillating 600 Mm. Sweep Suitable For Wall Mounting Installing . Make : Almond Or Other Equivalent Make Specified In Appendix B 52 Dg Set :- Supply, Installation, Commissioning And Testing Of Outdoor Silent Diesel Engine Driven Generating Set 415 Volts Ac, 3 Phase, 4 Wire System Of Supply, Engine As Per Bs 5514 / Iso 3046 And Alternator As Per Is 4722 / Bs 5000 Complete With Amf Panel Complete Comprising Ofrelay Panel For Automatic Starting On Mains Failure, Control Panel Having Meter, Sound Proof Canopyand Foundation Etc. Of Capacity 62.50 Kva Complete Of Manufacturer Or Oem ( Original Equipment Manufacturer ) As Per Cpcb Norms With And Includingfollowings :- ( A ) Alternator : Standard Design Alternator Rated At 62.50 Kva Net Out Put At Site After Considering Derating As Per Site Conditions At 0.8 ( Lag ) Power Factor Ac, 3-Phase, 4-Wire 415 Volts 50 Hz , 1500 Rpm, Self Excited Self Regulated Screen Protection Drip Proof Ip 23 Enclosure Brushless Design With Winding In Pole Faces, Insulation Class H And Voltage Regulation Of + / -1% At Rated Voltage From No Load To Full Load.The Alternator Shall Be Conforming To Is 4722 / Bs 5000 And Shall Be In Position To Generator Will Be Suitable For Tropical Climate And Shall Generally Confirming To Bs-5000 / Is-4722. ( I ) Insulation Class - H ( Ii ) Temperature Rise Class H ( Iii ) Excitation : Self Excitation ( Iv ) Regulation Performance : The Voltage Is Kept Constant With + / - 1%, Mannual Voltage Adjustment Within + / - 5%. ( V ) Frequency Regulation + / - 1%. ( B ) Diesel Engine :-The Engine Shall Be Air Cooled 62.5 Kva / 83 Bhp And Suitable For Generating 3 Phase , 62.5 Kva, 50Kw Power, Oil Lubricated, Exhaust Silencer, Self Starting Arrangement And Battery Charger Unit, Developing 1500Rpm Suitable For Above Output, Directly Coupled Through Flexiblecoupling, Multi Cylinder, Multi Strokedirect Injection, Cold Starting 1500 Rpm, As Per Relevent Isi / Bs-5514 With An Over Load Capacity Of 10% For One Hour In 12 Hours Continuos Running Complete With Standard Accessories All As Specified And Required For Safe Handling And Operation Silent Features Of Accessories Shall Be As Under :- 53 ( I ) Fly Wheel With Housing. ( Ii ) Cooling System :- Mounted Radiatorwith Fan & Belts. ( Iii ) Cooling Water Pump :- Centrifugal Type Belt Driven. ( Iv ) Exhaust System Shall Be As Per Design Of Manufacturer And Mounting Of Exhaust Pipe Shall Be As Per Site Requirement. ( V ) Exhaust Manifold, Silencer : Residential Type. ( C ) Fuel System :- Fuel Injection System With Fuel Injectors, Fuel Injection Solenoid Switch / Nozzles / Governer Electronic Type Capable For 1% Speed / Frequency Regulation, Fuel Filters, Fuel Houses. ( I ) Lub Oil System :-Lubricating Oil Filter.Lubricating Oil Pump. ( Ii ) Air Intake System:- Air Intake Manifoldair Cleaner Dry Type ( Iii ) Governer :-Hydro Mechanical. ( Iv ) Starting System :-Electric Self Starter With Maintenance Free Batteries Including Battery Charging Alternator. ( V ) Batteries :- 01 Nomaintenance Free Batteries Of 12 Volt 120 Ah Capacity Complete With Copper Conductor Multistraded Leads Of Suitable Length From Self Starter To The Battary Terminalscomplete With Initial Charge And Initial Fill Of Electrolite All As Speicified. Starting Gear Ringstart / Stop Shall Be As Per Manufacturer Design With Latest Technology. ( Vi ) Handling And Operation:- Salient Features Of Accessories Shall Be As Under :-Radiator With Blower Fan.Corrosion Inhibitor Coolant.Paper Element Filters For Fuel, Lub Oil.Fly Wheel Housing And Fly Wheel. 54 ( D ) Generator Monitoring Panel :-Shallcomprising Of Following ( I ) Microprocessor Based Gen Set Controller For Metering , Monitoring , Governing And Protection. ( Ii ) Engine Protection For Lub Oil Pressure, High Coolant Temperature ( Alarm & Shut Down ) . ( Iii ) Alternator Protection Parameters Like Under Under Voltage, Over Current , Under Frequency, Over Frequency ( Alarm & Shut Down ) . ( Iv ) Relay Drivers For Remote Annuciations. ( V ) Cyclic Cranking. ( Vi ) Auto / Manual Start / Stop. ( Vii ) Alternator Time Adjustment From The Front Key Pad. ( Viii ) Operates Within A Temperature Range 0-50? C And Humidity Upto 95%. ( Ix ) Remote Monitoring Capacity Through Separate Interface Modules. ( X ) Genset Metering Parameters Line Lube Oil Pressure, Coolant, Temperature, Engine Speed ( Rpm ) , Run Hours, Dc Voltage, 3 Phase Volts And 3 Phase Amperes , Frequency, Kw, Kva, Power Factor Etc. ( Xi ) Safety Controls :- Engine Low Lube Oil Pressure, High Water Temparature And Over Speeding Of Engine. ( Xii ) Mccb, 4 Pole 125 Amps Breaking Capacity 16 Ka Thermal Magnetic Release - 01 No ( Xiii ) Coupling Arrangement :-Flexible Coupling / Close Coupling As Per Manufacturers Design. ( Xiv ) Accessories:-Avmpads As Per Manufacturers Design. ( Xv ) Base Frame Made Out Of Ms Channels As Per Manufacturers Design. 55 ( Xvi ) Fuel Tank :-Daily Service Fuel Tank Of Capacity Suitable For 12 Hrs Continuous Operation Made Out Of3 Mm Thick ( Heat Retardant ) Sheet Top And Bottom With Calibrated Level Indicating Arrangement , Stop Cock , Drain Plug , Fuel Pump Of Suitable Capacity And Connected Pipe Line Should Be Installed With Inbuilt Tank Inside The Accousticenclosure Is Inclusive Of The Cost Of Dg Set And Is As Per Manufacturers Design . ( Xvii ) Deliverables :- Confirms The Norms Established By Cpcb. ( E ) Amf Panel :- ( I ) Auto Main Failure ( Amf ) Panel Made Out Of 2 Mm Thick Crca Sheet , Powder Coated Of Confirming To Is 8623 Totally Enclosed Dust And Vermin Proof With Front And Rear Openingof 415 Volts, 3 Phase, 4 Wire , Ac 50 Hz Having Copperbus Bar Capacity Required To Carry Current At 110% Load Of 62.50Kva Dg Set With Three Phase And Half Neutral Colour Coded, Pre-Wired With Copper Flexible Cable All As Speciified With The Following Accessories, Control Cable From Gen Set To Amf Panel :- ( Ii ) 125Amps, 3 Pole Contactors -02 Nos ( Iii ) 125Amps Tp Contactor Forneutral For Both Supplies. ( Iv ) Mccb, 4 Pole 125 Amps, Breaking Capacity 16 Ka Thermal Magnetic Release - 02 Nos For Both Supplies. ( V ) Cts For Both Supplies. ( Vi ) Dc Ammeter. ( Vii ) Dc Voltmeter ( Viii ) Push Buttons. ( Ix ) Indication Lamps ( X ) 2 Over Load + Earth Leakage Relay. ( Xi ) Multi Functional Digital Meter For Kwh, Kva, Kw, Amps , Volts, Frequency, Power Factor Etc. ( Xii ) Smps Battery Charger 24 V, With Trickle & Boost Charging. 56 ( Xiii ) On / Off Switch. ( Xiv ) Voltage Sensing Relay. ( Xv ) Automatic / Manual Relay. ( Xvi ) Hooters ( Xvii ) Voltage Sensing Relay ( Xviii ) Six Window Anunciator For Fault Indications. ( Xix ) Electro Magnetic Relay. ( Xx ) Change Over Switch Tp Of 125A On Load Type For Bypass The Supply-01 No. ( F ) Acoustic Enclosure :-Enclosure Is Free Standing Floor Mounted Factory Built And Modular In Construction To Facilitate Easy Assembly At Work Site And Will Be Drop Over Housing Type. Itwill Be Consist Of Acoustically Treated Panel Housed In Sheet Steel Will Provide Easy Access For Maintenance, Repairs And Operation. The Enclosure Is Custom Built To Suit Conditions With The Following Features :- ( I ) Custom Built Product For Various Equipments, With Ensure The Optimum Performance Without Duration. ( Ii ) Rugged In Construction Maintenance Free And Modular Designs Which Facilitate Easy At Site. ( Iii ) 1.6 Mm Thick Crca Sheet To Be Used For Enclosure Panel To Ensure Longer Life Against Weathering Action. High Quality Acoustic Insulation Materials To Be Used As Per Is 8183 For Maximum Sound Absorption. Acoustic Layers Are Supported By Perforated Sheets. ( Iv ) Sheet Metal Components Of The Enclosure Should Undergo Various Stages Of Surface Treatement Prior To Painting Which Leads To Be Better Life Of The Enclosure Against Weathering Action. ( V ) Special Paint Treatment With Pure Polyester Powder / Epoxy To Be Provided For Better Weather Resistance. ( Vi ) Well Designed Ventilation System To Be Provided To Pump The Heat In The Chamber Efficiently. 57 ( Vii ) For Effective Acoustic / Weather Sealing A Special Type Weather Sealing Gaskets, New Frame Rubber Gasket Tobe Used. ( Viii ) Working Space Is To Be Provided Around The Equipment For Easy Maintenance And Repair. ( Ix ) Necessary Cut Out Provision For Exit And Entry Of Fuel Lines Cable To Be Incorporated In The Enclosure As Per The Requirement. ( X ) A See Through Transparent Window ( Glass Or Acrylic ) In Front Of The Engine Panel To Provide For Monitoring The Operation. ( Xi ) Ducting If Required, Bellows, Mechanical Hardware Like Locks, Hinges, Fasteners Etc To Be Provided. ( Xii ) Deliverable 75 Dba @ 1 Mtr At 75% Load Under Free Fieldcondtions.The Temp Inside The Enclosure Will Be Within As Per Manufacturers Recommendations Above Ambient Temp. ( Xiii ) The Enclosure Should Be Provided With Bulk Head Fitting For Inside Illumination. ( Xiv ) The Batteries Shoulod Be Placed Inside The Enclosure Beside The Dg Set On A Suitable Insulated Platform. ( Xv ) The Dg Set Should Be Provided With External Emergency Stop Push Button. ( Xvi ) The Acoustic Enclosure Parts Shall Be Of Power Coated After Pre Treatment Process.The Powder Coating Shade Should Be Gen Set Green.The Base Frame Should Be Painted With Epoxy Based Black Shade.Make For Amf Panel : Dg Set Oem Or Equivalent Makemake For Acoustic Panel : Dg Set Oem Or Equivalent Make ( G ) Civil Work :- All Civil Works Including Pcc Platform And Items Related To Foundation Including Of Panel And Equipments Including Making Good And Existing Structure Of Disturbed During Installation And Commissioning Of Gen Set Shall Be Included In Quoted Rate.The Depth Of The Foundation Shall Be Minimum 600Mm With Antivibration Pads Or As Recommended By The Manufacturer. 58 Rubber Matting : 2000 Mm X 1000 Mm X 12 Mm Thick Matt Having Chequered Finish On Top Isi Marked 1100 Volts Grade And Each Shall Be Laid In Front Of Control Panel And Dg Set As Directed.Note :-The Following Items Are Deemed To Be Included In The Rate Quoted For Dg Set : ( I ) The Capacity Of Gen Set Shall Be Net After All Due Derating Factors As Per Relevant Isi Standard. ( Ii ) The Quoted Rate Shall Be Deemed To Be Inclusive Of First Filling Of Lubricating Oil And Final Successful Acceptance Test. ( Iii ) The Quoted Rate Shall Be Deemed To Be Inclusive Of 12 Hours Test Run At Site Including Of One Hour On 10% Overload In Presence Of Representative Detailed By Accepting Officer. All Arrangements Are To Be Made By The Contractor For Tests At Site. ( Iv ) Rate Quoted Shall Be Deemed To Be Included In Making Necessary Holes To Wall And Making Good To Disturbed Surfaces To Match With Original Specification And Connection Up All As Specified And Directed. ( V ) Dhpp ( N ) For Testing Purpose Shall Be Supplied By The Contractor Without Any Extra Cost To Govt. ( Vi ) The Contractor Shall Arrange For Water Load For Testing For Final Testing Of Dg Set At Site And The Cost Is Deemed To Be Included Inthe Unit Rate For Dg Set. ( Vii ) Testing Of Sound Level Shall Be Carried Out At The Site In Presence Of Ge And Test Result Shall Also Be Signed By The Ge. ( Viii ) Standard Documents As Per Manufacturer Specifications Such As Maintenace & Operation Mannual, Parts Catalogue, Display Charts Such As Maintenace And Oil Change Chart / Board ( For Generator And Diesel Engine ) And Log Book As Directed By Engr-In-Charge. 59 Eot Crane :- Supply, Installation, Testing And Commisioning Of Electrically Operated Over Head, Double Girder, Indoor Type Eot Crane Having 15 Ton Main Hoist Capacitywith Operation Facility From Floor Through Push Button, 54 Mtrs Span Length, 7 Mtrsheight Of Lift And 17 Mtrs Cross Travels With Suitable Sizes Of Lt Wheel And Lt Crane Rail 15 Ton For 54 Mtrs. Dsl With Insulator For 60 Mtrs ( Aprox ) Including Suitable Long Travel Girders All Design Standard Snail Confirm To Is 3177, Is 807. ( The Above Dimensions Are Approx , Before Installation It Is To Be Verified For The Accurate Dimension At Site ) 1.Type And Class Of Crane : Indoor Duty, Eot Crane ( A ) Crane Structure Push Button Operated, Double Girder. ( B ) Hoist Capacity As Per Is: 807 & 3177 And The Folowings ( I ) Rated In Tonnes - 15 Ton ( Ii ) Tested In Tonnes - 125 % Of Rated Load. ( C ) Cross Travel - 17 Mtrs As Per Is :807 & 3177 ( D ) Long Travel -54 Mtrs As Per Is :807 & 31772. Safe Working Loadmain Hoist - 15 Ton3. Operating Speed ( Loaded ) ( I ) Main Hoist - 1.3 Mtr / Min With 0.3 Mtr / Minmicro Speed ( Ii ) Cross Travel - 15 Mtr / Min With1.5 Mtr / Min Micro Speed ( Iii ) Long Travel - 20 Mtr / Min With 2 Mtr / Min.Micro Speed4. Centre To Centre Of Gantry Track - 54 Mtrs ( Approx ) 5. Minimum Working Clearances Required ( I ) Distance From Centre Of Gantry Rail To Nearest Side Obstruction ( A ) - 0.35 M , ( B ) -0.35 M Complete All As Specified And Directed As Per Ground Requirement Basis. 60 ( Ii ) Vertical Distance From Top Of Gantry Rail To Nearest Side Obstruction ( C ) - 1.8 Mtrs ( Approx ) ( Iii ) Distance From Floor To Top Of Gantry Rail ( D ) - 7 Mtrs ( Approx ) ( Iv ) Nearest Position Of Hook To Centre Line Of Gantry Rail Dsl End - 0.80 Meters And Other End-0.80 Meters And Vertical Clearance To - 6.0 Meters Under Side Of Bridge-K Complete All As Specified And Directed As Per Ground Requirement Basis.6. Type Of Hook Supplied - Plain Shank Forged Steel As Per Is 5749.7. Height Of Hook Above Floor Level - 7 Meters8. Drop Of Hook Below Level - Nil9. Section Of Gantry Rail Recommended - 60 Lb / Yard Or 50X50 Sq.Bar Complete All As Specified And Directed Suitable Size & Capacity As Per Design Of 15 Ton Cap Of Eot Crane As Per Ground Requirement Basis.10. Type Of Main Girder / Long Travel Girder ( I ) Braced, Box Plate Or Lattice - Plate Box, Radiographically Girder Or Rolled Steel Joist Tested ( Ii ) Riveted Or Fusion Welded - Fusion Welded11. End Carriages ( I ) Wheel Base - 4200Mm 08 Nos Lt Wheel Complete All As Specified And Directed Of Suitable Size . ( Ii ) Material Of Travelling Wheels - Forged Steel ( Iii ) Maximum Load Excluding Impact - 20.25 Tonnes On Travelling Wheels12. Type Of Plat Form Provided Number - Both Side Full Length Chord Length And Width Plate Platform With Toe Board & Two Tiered Guard Railing Of 25 Mm Dia Heavy Duty G.I Pipe.13. Crab ( I ) Centre Of Traverse Wheels - 1100 Mm ( Size To Be Decided As Per Ground Reqmt And Capcity Of Eot ) ( Ii ) Materials Of Traverse Wheels - Forged Steel 61 14. Hoisting Ropediameter Construction Quality No Of Minimum ( Mm ) Steel Fails Breaking Strength For Main Hoist Minimum 16Mm 6X36 1770 Grade 20 T And Maximum To Be Decided As Per Ground Base Reqmt Complete All As Specified And Directed.15. Factor Of Safetyhoist - 6 Min16. Description Of Brake ( I ) Hoisting Motion Brakes - Electromagnetic ( Ii ) Traversing Brakes - Electromagnetic ( Iii ) Travelling Brakes - Electromagnetic16a. Power Supply Ac, 415Volts, 3 Phase, 50 Hertz Frequency And 3 Number Of Wires.17. Motors ( A ) Temparature Rise : As Per Is :325 For Ambient 50 Degree Centi Grade. ( B ) Motion Qtly - Type Hp Rev / Min Enclosure Rating. ( C ) Main Hoist Min 1 Sq Cage 5 960 T.E.F.C 40% Cdf And Maximum To Be Decided As Per Ground Basis Reqmtcomplete All As Specified And Directed.Long Travel 3 Sq Cage 1 960 T.E.F.C 40% Cdf And Maximum To Be Decided As Per Ground Basis Reqmtcomplete All As Specified And Directedcross Travel 1 Sq Cage 1 960 T.E.F.C 40% Cdf And Maximum To Be Decided As Per Ground Basis Reqmtcomplete All As Specified And Directedmicro Hoist 1 Sq Cage 1 960 T.E.F.C 40% Cdf And Maximum To Be Decided As Per Ground Basis Reqmtcomplete All As Specified And Directed18. Details Of Controllers & Equipment : Push Button Operated From Ground With All Required Electrical Equipment. 62 19. Particulars Of Safety Devices ( A ) Limit Switches On All Motions. ( B ) Mechanical & Electrical Inter Lock ( C ) Wheel Stops For Ct Wheels ( D ) Axel Lugs ( E ) Safety Buffers ( F ) Hrc Fuses And Overload Relaysnet Weight : ( A ) Complete Unladen Crane : As Per ManufacturerS Dsign ( B ) Complete Unladen Crab : As Per ManufacturerS Designnote : ( I ) Rate Includes Also For Long Travel Girder Suitable For Above Crane With 54 Mtrs Long Both Sides. ( Ii ) Clear Height Of Crane Hook Shall Not Be Less Than 5 Meter From Finished Floor Level. ( Also Refer Ps Clause No. 22 )