}

Tender For Essential Repair And Maintenance Work In T.E. Building At Gurudwara Road Saharanpur., gurudwara-Uttar Pradesh

Government Departments has published Tender For Essential Repair And Maintenance Work In T.E. Building At Gurudwara Road Saharanpur.. Submission Date for this Tender is 04-01-2024. Building Work Tenders in gurudwara Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41345702
Tender For Essential Repair And Maintenance Work In T.E. Building At Gurudwara Road Saharanpur.
Open Tender
Indian
Uttar Pradesh
Gurudwara
04-01-2024

Tender Details

Tender For Essential Repair And Maintenance Work In T.E. Building At Gurudwara Road Saharanpur. ; 1 Providing And Fixing M.S. Handle Of Size 100 Mm For M.S. Window All Complete As Per Direction Of Engineer-In-Charge. 2 Providing And Placing 12 Mm Thick Mineral Fiber Gypsum Ceiling Tiles Of Approved Texture Of Size 595X595 Mm In The Old Existing Frame Of False Ceiling, Of Required Pattern And Colour All Complete As Per Direction Of E-In-C. 3 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) ( I ) Single Socketed Pipes. ( A ) 75 Mm Diameter 4 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) ( I ) Single Socketed Pipes. ( B ) 1000 Mm Diameter 5 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( A ) Single Tee With Door ( I ) 75X75x75 Mm 6 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( A ) Single Tee With Door ( Ii ) 110X110x110 Mm 7 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( B ) Bend 87.5° ( I ) 75 Mm Bend 8 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( B ) Bend 87.5° ( Ii ) 110 Mm Bend 9 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( C ) Shoe ( Plain ) ( I ) 75 Mm Shoe 10 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( C ) Shoe ( Plain ) ( Ii ) 110 Mm Shoe 11 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hardwood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. ( A ) 75 Mm 12 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hardwood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. ( B ) 110 Mm 13 Resetting The False Ceiling By Adjusting Leveller Hanger Frame Members Etc With Required Screws, Nut & Bolts Etc All Complete As Per Direction Of E-In-C. 14 12 Mm Cement Plaster Of Mix : ( A ) 1:6 ( 1 Cement: 6 Coarse Sand ) 15 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix : ( A ) 1:6 ( 1 Cement: 6 Coarse Sand ) 16 Finishing Walls With Water Proofing Cement Paint Of Required Shade : ( A ) New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 17 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : ( A ) New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sum ) 18 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 19 Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc ( Volatile Organic Compound ) Content Less Than 50 Gram / Litre, Of Approved Brand And Of Required Shade And Colour Complete To Give And Even Shade. ( A ) Old Work ( One Or More Coats ) 20 White Washing With Lime To Give An Even Shade : ( A ) Old Work ( One Or More Coats ) . 21 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 22 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : ( A ) 23 Finishing Walls With Water Proofing Cement Paint Of Required Shade : ( A ) Old Work ( One Or More Coats @ 2.20 Kg / 10 Sqm ) Complete. 24 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : ( A ) Old Work ( One Or More Coat Applied @ 0.90 Ltr / 10 Sqm ) . 25 Applying One Coat Of Exterior Primer Of Approved Brand And Manufacture Applied @ 1.20 Kg / 10 Sqm. 26 Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per ManufacturerS Specification. ( A ) Two Or More Coats On Old Work After Scrapping Work. ( Payment Of Scrapping Works Shall Be Paid In Separate Item ) . 27 Providing And Fixing Single Scaffolding System On The Exterior Side Up To 7 Story Height Made With 40 To 50 Mm Dia Bamboo, 1.5M C / C Horizontal And Virtical Bamboo Joining With Rashi With Bamboo Challies For Working Platform Etc. And Maintaining It In A Servisiable Condition For The Required Duration As Approved And Removining It There After, The Scaffolding System Shall Be Shifted With Bracing Runners Connection With Building Etc. For Inspection Of Work At Required Location With Essencial Safety Feature For Workmen Etc. Complete As Per Direction Of Engineer In Charge . The Elevation Area Of The Scaffolding Shall Be Measured For Payment Purpose. The Payment Will Be Made One Irrespective Of Duration Of Scaffolding ( To Be Used For Maintenance Work Judicially , Necessary ) 28 Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq. Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground , All Complete As Per Directions Of Engineer-In-Charge. ( A ) With Cement Mortar 1:4 ( 1Cement: 4 Coarse Sand ) . 29 Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Racking Out The Old Putty: ( A ) Float Glass Panes Of Nominal Thickness 4 Mm ( Weight Not Less Than 10Kg / Sqm ) . 30 Refixing Old Glass Panes With Putty And Nails . 31 Repair Of Broken Projection / R.C.C. Column By Dismantling Damaged Portion, Repair By Cement Plaster 1:4 ( 1Cement:4 Coarse Sand ) In One Or More Layer In The Interval Time All Complete As Per Direction Of E-I-C. ( Item Included Labour, Material Etc, , Scaffolding If Required Will Be Paid In Separate Item ) . 32 Taking Out The Large Peepal Tree At Roof And Walls Including Root Which Was Embedded In Roof At All Heights By Demolishing The Roof Tiles Or Brick Wall If Required Including Disposal The Tree Material And Malba Out Of Municipal Limit Including Repair Of Roof With Cement Concrete 1:2:4 ( 1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size ) All Complete As Per Direction Of Engineer-In-Charge. ( The Item Included All Labour, T&P, Material In Above Operation 33 Repairs To Door / Windows Shutter ( Area Upto3 Sqm ) Including Taking Out And Refixing The Same And Replacement Of Hinges With Screws / Greesing Wherever Required Etc Complete 34 Extra For Providing Transparent 3 Mm Thick Acrylic Sheet Instead Of 4 Mm Thick Plain Glass, Fixing With Silicon Adhesive Before Applying Putty And Nails All Complete As Per Direction Of E.I.C. 35 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. 36 Extra For Cutting Reinforcement Bars Manually / By Mechanical Means In R.C.C. Or R.B. Work ( Payment Shall Be Made On The Cross Sectional Area Of R.C.C. Or R.B. Work ) As Per Direction Of Engineer In-Charge. 37 Credit To Unsevisiable Wooden Door. 38 Credit To Unservisiable Ms / Gi .

Key Value

Document Fees
INR 590 /-
EMD
INR 11424.0 /-
Tender Value
INR 5.71 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail