Tender For Improvement Of Certain Smqs At Air Force Station Amritsar Cantt ( Phase - Ii ) ; 1 Building Work 2 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roofs Complete All As Specified And Directed 3 Demolition Of Mud Inroofs Any Thickness, Including Plastering And Leeping ( Whether Full Thickness Removed Or Only A Part Thereof ) Etc Complete All As Specified And Directed 4 M&L For App Based Polymeric Membrane Minimum Weighing 3 Kg / Sqm And Minimum 3 Mm Thick Reinforced With Polyster Non Wove Fabric ( Weight Notless Than 150 Gms / Sqm ) Laid On Primed Surface By Forced Application With And Including Approved Bitumen Primer As Per ManufacturerS Instructuctions Including Cleaningthe Surfaces Complete All As Specified And As Directed.Note:Sheet Shall Be Five Layered Prefabricated Atactic Polypropyleen Polymer ( App ) Modified 3 Mm Thick Membrane ( Weighing Not Less Than 3 Kg / Sqm ) Reinforced With 150 Gsm Polyester Non- Woven Fabric. Concrete Of Roof Surface Shall Be Scratched With Scratched Tool Before Finishing Roof Surface When The Concrete Surface Is Still Green, 10Mm Thick 1:4 Cement Plaster Shall Be Laid .The Roof Surfaces Shall Be Throughly Wire Brushed, Washed, Dried Up And Cleaned To All Foreign Matter And Dust Prior To The Appliction Of Primer. On The Dried Surface One Coat Of Approved Bituminous Primer, Having Density In The Range Of 0.87 To 0.89 Kg / Litre At 25 Degree Centigrade And Viscosity Of 40 To 160 Cps, Manufactured By Same Manufacturer @ 0.4 Litre / Sqm Shall Be Applied. App Membrane Shall Be Laid On Primed Surface By Torch Application Method After Allowing 24 Hours For Primer To Dry . Laying Off App Membrane Will Normally Be Laid In Length At Right Angle To The Direction Of Slope. The Overlaps Shall Be Of Minimum 100Mm On Longitudinal Direction And 150 Mm On The Transverse Direction. All Overlaps Shall Be Bonded With Bitumen Primer And Levelled By Heating The Overlaps With Butane Torch. The Treatment Shall Be Done By The Approved Authorised Applicatiors. 5 M&L For Pcc 1:2:4 Type B-1 50Mm Thick ( Average ) ( Using 20 Mm Graded Stone Aggregate ) Mixed With Water Proofing Compoundas In Padding Roofto Maintain Slope, Correction Of The Depressed Undulaution Portion And In Roof Kerb Etc. Complete All As Specified And As Directed. 6 M&L For Brushing Neat Cement @ 3.0 Kg Per Sqmcomplete All As Specified And As Directed. 7 M&L For 40Mm Thick Brick Tiles Laid On Concrete Roof Padding Over And Including 15 Mm Thick Cement Screed Bed In Cm ( 1:6 ) Using Grey Cement, Jointed And Grouted Flush In Cement Mortar ( 1:3 ) Mixed With 5% Of Crude Oil By Weight Of Cementcomplete All Specified And As Directed. 8 M&L For 40Mm Thick Brick Tiles ( Except Tiles ) Laid On Concrete Roof Padding Over And Including 15 Mm Thick Cement Screed Bed In Cm ( 1:6 ) Using Grey Cement, Jointed And Grouted Flush In Cement Mortar ( 1:3 ) Mixed With 5% Of Crude Oil By Weight Of Cementcomplete All Specified And As Directed. 9 M&L For Pcc 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregates ) As In Roof Kerbs Or Mud Stops, Rounded Or Chamfered On Edges Complete All As Specified And As Directed 10 Demolition Of Brick Work Builtin Cement Mortar Incl All Quoins, Arches, Pillars Etc Complete All As Specified And Directed . 11 M&L Forbrick Work With Old Size Sub Class B Bricks, Straight Or Curved On Plan Exc 6 M Mean Radius, Built In Cm 1:4 Complete All As Specified And As Directed . 12 M&L For Demolition Of Reinforced Cement Concrete In Any Position And Any Description Including Cutting Of Reinforcement Bars To Facilitate Demolition Complete All As Specified And Directed. 13 Material And Labour For Reinforcement Cement Concrete ( Nominal Mix ) ( 1:2:4 ) Type B-1, Using 20Mm Graded Crushed Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And Directed. 14 M&L For Mild Steel Tmt Bars 10 Mm Dia And Over Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia., Or Securing With Clips Complete All As Specified And Directed. 15 Material And Labour For Formwork To Sides And Soffits Ofroof Beams, Lintels, Cantilever, Shelves, Splay Between Floor And Beam Etc., Flat Fair Finished Concrete Surfaces, Complete All As Specified And Directed. 16 Taking Down Cement Plaster On Brick Or Concrete Surfaces Etc Including Racking Out Joints Hacking For Key, Scrubbing Down With Water Etc ( From Walls And Ceiling Surfaces Of Any Description ) & Removing Debries Out Side The Mod Land To A Desiginated Place Earmarked By The Local Administration Complete All As Specified And As Directed. 17 M&L For Rendering 10Mm Thick In Cement Mortar ( 1:3 ) On Concrete Surfaces As In Ceiling, Finished Even And Smooth Without Extra Cement Complete All As Specified And As Directed. 18 M&L For Rendering 15Mm Thick In Cement Mortar ( 1:4 ) Mixedwith Water Proofing Compound @ 3% By Weight Of Cementfinished Even And Fair Without Extra Using Cement Complete All As Specified And Directed.Note:- Wpc Shall Be Measured And Paid For Separately. 19 M&L For Rendering 20Mm Thick In Two Layers ( 15+5Mm ) On Concrete Surfaces In Cement Mortar ( 1:4 ) In Patches At Columns, Chajja, Canpoy And Soffits Using Gi Chicken Wire Mesh With &Including Necessary Scafolding As Required At Site Complete All As Specified And As Directed. 20 M&Lfor Rendering 15 Mm Thick In Cement Mortar ( 1:6 ) On Fair Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cementcomplete All As Specified And Directed. 21 M&L For Preparation Of New Plastered Surfaces As In Ceiling And Applying Three Coats Of White Wash Complete All As Specified And As Directed. 22 M&L For Complete Removal Of Existing Treatment And Applying Three Coats Of White Wash As In Ceiling Complete All As Specified And As Directed. 23 M&L For Preparation Of Newly Plastered Surfaces Of Walls And Applying Two Coats Of 1St Quality Water Baseddistemper Over And Including1mm Thick Wall Care Putty To Obtain Smooth Regular / Even Finish Over A Coat Of Primer Complete All As Specified And As Directed. 24 M&L For Complete Removal Of Existing Treatment On Walland Applying Two Coats Of 1St Quality Water Baseddistemperover And Including1mm Thick Wall Care Putty To Obtain Smooth Regular / Even Finish Complete All As Specified And As Directed. 25 M&L For Preparation Of Newly Plastered Surfaces Of Walls And Applying Two Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm Over New Surfaces, Complete All As Specified And Directed. 26 M&L For Complete Removal Of Existing Treatment And Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm Over New Surfaces, Complete All As Specified And Directed.Note For Item No 1.24 &1.25: Weather Proof Exterior Emulsion Paint And Primer Shall Be Of Same Manufacturer. 27 Supplyonly Intergral Water Profing Compound Complete All As Specified And As Directed. 28 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) And Rubbish Off The Premises Complete All As Specified And As Directed. 29 M & L For Coloured Non Skid / Matt Finish Ceramic Tiles, 7 To 8 Mm Thick, ( Square / Rectangular ) , Area Of Each Tile Exceeding0.18 Sqm But Not Exceeding 0.38 Sqmin Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over Andincluding Screed Bed Or Bedding Layer Of 15 Mm Thick In Cement Mortar ( 1:6 ) Complete All As Specified And As Directed. 30 All As Per Item No 1.28 Here-N-Before But As Indado, Riser & Skirting Over & Incl 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And As Directed. 31 M & L For Coloured Non Skid / Matt Finish Ceramic Tiles, 7 To 8 Mm Thick, ( Square / Rectangular ) , Area Of Each Tile Exceeding0.11 Sqm But Not Exceeding 0.18 Sqm Sq.Min Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over Andincluding Screed Bed Or Bedding Layer Of 15 Mm Thick In Cement Mortar ( 1:6 ) Complete All As Specified And As Directed. 32 M&L For Coloured Glazed Ceramic Tiles Of Size 350 X 250 X 7Mm / 450X350x7 Mm Thick On Vertical Surfaces Such As Skirting / Dado, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match Over Andincluding Rendering 10Mm Thick In Cement Mortar ( 1:3 ) Complete All As Specified And As Directed. 33 M& L 16 To 18 Mm Thick Baroda Green Marble ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps, Jambs, Urinal Partitions, Pillars, Window- Cills, Cooking Platforms And Thelike In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match Withshades Complete All As Specified And As Directed. 34 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Not Exc. 1.5Sq.M Each Complete All As Specified And As Directed. 35 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutter From The Frames ) Exc. 1.5Sq.M But Not Exc. 4Sq.M Each Complete All As Specified And As Directed. 36 Taking Down Shuttersexc 1 Sq. M And N Exc 2 Sq. M Each Complete All As Specified And As Directed. 37 S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With Ms Square Tube, Supplying And Fixing In Opening As Per Specifications And Drg, Complete All As Specified And As Directed. 38 S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of Ms Tube For Top And Bottom Rails. Ms Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail, Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying And Fixing In The Frame At Site Complete All As Specified And As Directed. 39 S&F Pressedsteel Frames Of Size 105 X 60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate Etc Complete All As Specified And As Directed. 40 S&F Pressedsteel Frames For Doors Size Of Frame 125 X 60 Mm With One Or More Rebates Including Necessary Fixing Lugs Hinges Lock Strike Plate Etc Complete All As Specified And As Directed. 41 S&F 30 Mm Thickflush Shutters , Solid Core Constrution With Block Board Core And Plywood Face Panels, Commercial Type On Both Side Complete All As Specified And As Directed 42 S&F 35 Mm Thick, 2Nd Class Hard Wood, Glazed & Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze Etc. ( Without Sash Bars ) , Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitered Beads For Securing Glass Etc. Sizes Of Members Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 ( A ) Complete All As Specified And As Directed. 43 S&F Flush Shutters For Cup Board20mm Thick Solid Core Construction, With Block Board Core And Plywood Face Pane, One Face Commercial Type And The Other Face Is Covered With Decorative Face Veneer With Lipping / Frame To Match Complete All As Specified And As Directed. 44 S&F Stainless Steel Butt Hinges Medium Weight Of Size 100Mm Complete All As Specified And As Directed. 45 S&F Extruded Aluminium Alloy Handles, Fabricated Type, Anodised Of Size 150 Mm Complete All As Specified And As Directed. 46 S&F Aluminium Anodised, Barrel Tower Bolts Of Extruded Section With Length Of Bolt 150 Mm And Fixed Complete All As Specified And As Directed 47 S&F Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp And Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy With Length Of Bolt 250 Mm And Fixed Complete All As Specified And As Directed. 48 S&F 140Mm Long Floor Door Stopper Of Aluminium Alloy Body And Tongue With Hard Drawn Steel Springcomplete All As Specified And As Directed. 49 Supply And Fixingfactory Made Box Type Steel Window With Pintol Hinges & 2 Nos 150Mm Mild Steel Tower Bolts To Each Shutter, Steel Handle And With Glazing Bars Dovetailed Or Welded, Including Provision Of Grill As Per Drawing With And Including One Shop Coat Of Zinc Chromate Primer Complete All As Specified And Shown On Drawing No Ceaf / Std-185-2012 Sheets 1 / 3, 2 / 3 & 3 / 3. 50 S&F Framed Work Such As Grill Grating / Cooler Stand Etc With Ends Of Bars Shouldered And / Or Riveted Or Forged Into Spikes Frame Gurads Bars Barred Iron, Door Ladders, Framed Balusters Walk Way Railings Frame Work Of Water Tanks And Similar Work Complete All As Specified And As Directed 51 S&F Galvanised Mild Steel Wire Cloth 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm Fixed With Screws Or Beading In Steel / Wooden Door / Window Complete As Specified And Directed. 52 S&F Sheet Glass 3Mm Thick Ordinary Qualityand Glazing With Oil Putty In Squeres N.Exc 0.5 Sqm In Each Panescomplete All As Specified And As Directed 53 M&L For Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer On New Steel Surface Of Any Description Over 10 Cm Width Or Girth Not Otherwise Described Including Prepration Of Surface Complete All As Specified And As Directed 54 All As Per Item No. 1.52 Here-In-Before But Except Primer Complete All As Specified And As Directed 55 M&L For Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer On New Wooden Surface Of Any Description Over 10 Cm Width Or Girth Not Otherwise Describedincluding Prepration Of Surface Complete All As Specified And As Directed. 56 M&L For Machine Cut Kota Stone Slab, 20-23 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including, Cuttingand Mirror Polishing With And Including20 Mm Thick Screed Bed Or Bedding Layerin Cm 1:6 For Laying Floor Finishescomplete All As Specified And As Directed. 57 All As Per Item No. 1.55 Here-In-Before But As In Riser Of Steps, Dado / Pillars And Vertical Surfaces Etc Over And Including 10 Mm Thick Rendering On Brick Or Concrete Suface In Cm 1:4 After Taking Down Cement Plaster On Walls And Racking Out Joints, Hacking For Key, Scrubing Down With Water Etc Complete All As Specified And As Directed. 58 S&F In Repair Stainless Steel Sink 1Mm Thick With Drainage Board For Kitchen Or Laboratory With Plugs, Washers And Wastes, Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Contilever Brackets And Connecting Union To Pipe Overall Size 915 X 460 Mm With Bowl Size 410 X 330 X 160Mm Complete All As Specified And As Directed. 59 S & F In Repairs Vitreous China Wash Basin, White, Flat Back Of Size 450Mm X 300Mm Including Brackets Grouted In Cement Mortar 1:2 In Wall Complete All As Specified And As Directed. 60 S & F In Repairs Vitreous China Squating Pan Orissa Pattern Size 580 X 440Mm White With Integral Foot Rest ( Excluding, Flushing Cistern And Flush Pipe ) Including Connection To P Trap And To Flushing Pipe Complete All As Specified And As Directed. 61 S & F In Repair 10 Ltrs Capacity Pvc Low Level Syphonic Action Type Flushing Cistern Including Ball Valve, Bracket, Inlet, Outlet, Overflow And Pvc Connection Complete All As Specified And As Directed. 62 S & F32mm Bore ( Dia Of Discharge Pipe ) Waste Coupling Of Ptmt ( Half Or Full Threaded ) Minimum Weight 32Mm- 45Gms. Complete All As Specified And As Directed. 63 S & F In Repairs Pillar Taps Cast Copper Alloy With Capstan Head, Chromium Plated, Fancy Type, Screwed Down High Pressure, With Or Without Lettered ‘Hot’ Or ‘Cold’ With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipes 15Mm Bore Complete All As Specified And As Directed. 64 S&F Pvc Connection 15 Mm Size With Ptmt Nuts Of Length 450 Mm Complete All As Specified And As Directed. 65 S&Fpvc Waste Pipeflexible 32Mm Or 40Mm Bore 60Cm Long Forwhb & Sink Complete All As Specified And As Directed. 66 M&L For Galvanised Iron Tubing 15Mm Bore, Medium Grade, With All Fittingsfixedto Walls Or Ceiling Or Laid In Floors, In Concealed Pipe Work Including Making Good The Chases Etc In Cement Mortar ( 1:3 ) After Fixing Of Pipe, Including Taking Down Of Old Rusted / Unserviceable Gi Pipecomplete All As Specified And Directed. 67 All As Per Item No. 1.65 Here-In-Before But 20 Mm Bore Of Pipe Complete All As Specified And As Directed. 68 S & F In Repairsbib Tap, Cast Copper Alloy, Fancy Type, Chromium Plated, Screwed Down High Pressure, Screwed For15mm Bore Ron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. 69 S & F In Repairs Shower Rose 125 Mm Size Brass Chromium Plated With Swivel Type Joints Including Fixing To Steel Pipes Or Unioncomplete All As Per Specifiedand As Directed. 70 S & F In Repairs Cp Brass Towel Rail D Type 60 Cm Long And 20Mm Dia Fixed To Wall With Screws And Plastic Cleats Complete All As Specified And As Directed. 71 S & F In Repairs Stop Valve15 Mm Bore Of Pipe, Fancy Type, Chromium Plated With Long Shank And Cup ( Concealed Type ) Cast Copper Alloy, Screwed Down, High Pressure With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions Complete All As Specified And As Directed. 72 S & F In Repairs Stainless Steelplate Rack Made Out Of 1Mm Thick Stainless Steel Sheetwith Over All Size 600 Mmx750 Mmx250 Mm Complete All As Specified And As Directed. 73 S & F In Repairs Float Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For 20Mm Bore Of Iron Pipe Or Brass Ferrule Complete All As Specified And Asdirected. 74 S&F In Repairsstop Valves, Cast Copper Alloy, 20Mmbore Of Pipe , Screwed Down, High Pressure, Fancy Type Chromium Plated, Screwed, Both Ends For Iron Pipe Or For Unions And Fixedcomplete All As Specified And As Directed. 75 S & F In Repairs Angle Valve Of Ptmt, Any Colour High Pressure Screwed For 15Mm Bore Of Iron Pipes ( Minimum Weight 90 Gram ) Complete All As Specified And As Directed. 76 Dismantling Of Ci / Pvc Pipe Of 75 / 100Mm Dia Bore Fixed With Cement Joint Complete All As Specified And As Directed 77 S & F 110 Mm Dia Bore Pvc ( Swr ) Pipe ( Type B ) Having Pressure Rating 6 Kgf / Cm2 Single Socketed In Trenches / Floors In Any Length With Rubber Ring Joints Complete All As Specified And As Directed. 78 S & F 75 Mm Dia Bore Pvc ( Swr ) Pipe ( Type B ) Having Pressure Rating 6 Kgf / Cm2 Single Socketed In Trenches / Floors In Any Length With Rubber Ring Joints Complete All As Specified And As Directed. 79 S & F Pvc ( Swr ) Bend / Door Bend Any Radius For 110 Mmbore Pipe Incl Jointing Material Complete All As Specified And As Directed. 80 S & F Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequalfor 110Mm Diaborecompleteall As Spd And As Directed 81 S & F Pvc ( Swr ) Bend / Door Bend Any Radius For 75 Mmbore Pipe Incl Jointing Material Complete All As Specified And As Directed. 82 S&F In Repair 75 Mm Dia Pvc ( Swr ) Floor Trap / Nahani Trap Plain With Grating Including Jointing With Solvent Cement Complete All As Specified And As Directed. 83 S&F In Repair 110 Mm Dia Pvc ( Swr ) Floor Trap / Nahani Trapplain With Grating Including Jointing With Solvent Cement Complete All As Specified And As Directed. 84 S & F Pvc ( Swr ) Vent Cowl Equal Or Unequalfor 110Mm Diaborecomplete All As Specified And As Directed. 85 S&F In Repair Pvc Gully Traps Square Of Size 125Mm X 110Mm Including For Setting And Jointing To Drain With Cm 1:1 Complete All As Specified & Directed. 86 S&F Selected Quality 5.5Mm Thick, 600 X 450Mm Bevelled Edge Mirror, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified & Directed. 87 S&F In Repairs Rotational Moulded Pvc Water Storage Tanks 500 Ltrscapacity, Double Walled ( Isi Marked ) With Isi Marking Embossed On The Tank ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Complete All As Specified & Directed. 88 M&L 75Mm Thick Pcc 1:3:6 Type C-2 Using 40Mm Graded Crushed Stone Aggregate As In Plinth Protection Finished Even And Smooth Without Using Extra Cement With And Including Filling Of Expansion Joints With Mastic Filling Complete All As Specified And As Directed. 89 S & F Harrison Rails, Mild Steel, Chromium Plated With Fixing Brackets, Stops, Rollers Etc. Complete All As Specified & Directed. 90 M & L For Water Proofing Treatment To Sunken Portion Of WcS, Bathroom Etc By Applying Cemrnt Slurry Mixed With Acrylic Based Polymer Modified Cementitious Composite Compound Coating Of Approved Make Comprising Of Following : ( A ) Demolition And Removing Lean Concrete / Red Bajri / Moorum ( B ) S&F 450Mm Long 50Mm Dia Bore Of Gi Pipe Spout ( C ) Cleaning The Surcace And Applying 15Mm Thick Plaster In Cement Mortar ( 1:4 ) Using Water Proofing Compound @ 3% By Weight Of Cement On Floor And Sides Of Wall Of Sunken Portion And Finished The Surface Even & Smooth Using Extra Cement Complete. ( D ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Acrylic Based Polymer Modified Cementitious Composite Compound @ 0.253Kg / Sqm After Curing Of 4 Hours ( E ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Acrylic Based Polymer Modified Cementitious Composite Compound @ 0.126Kg / Sqm After Curing Of 4 Hours Followed With Curing Of 48 Hours. ( D ) After Treatment Of Surface Suken Portion To Be Tested For Water Tightness Any Leakage Or Seepage Is Obserbed Same Be Rectified Before Filling The Sunken Portion ( F ) M& L For Providing Lean Cement Concrete 1:5:10 Type E-2 Using 40 Mm Graded Brickaggregate In Sunken Filling. 91 Path / Hard Standing Work 92 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floors And Pavings N. Exe 15 Cm Thickness ( Below Or Above Ground Level ) Complete All As Specified And As Directed 93 M & L For 40 Mm Thick Pcc 1:2:4 Type B-1 ( Using 20 Mm Graded Stone Aggregate ) As In Sub Base Complete All As Specified And Directed. 94 S&F For 400 Mm X 400 Mmsize And 10 Mm Thick Premium Quality Outdoordeck Floor Non Skid Tiles Have Robust Surface And Elegant Design Rectangular In Shapeset And Jointed In Neat Cement Slurry Leaving 3 Mm Space / Grove Around All Four Sides Of Each Tile With The Help Of 3 Mm Wide Pvc Spacer And Pointed The Same With Approved Colored Epoxy Grout Over And Including 15Mmthick Screed Bed In Cm 1:6Complete All As Specified And As Directed. 95 M&L Plain Cement Concrete ( 1:2:4 ) Type B-1 Using 20 Mm Grade Crushed Stone Aggregate As In Coping, Road Side Interlocking Stops Including Use & Waste Necessary Form Work Complete All As Specified & Directed. 96 Internal Elecrification Work 97 Taking Down Carefully Copper / Aluminum Point Wiring ( Light, Fan, Socket Or Power ) Complete With Fittings Such As Switches, Ceiling Roses, Pendants, Lamp Holders, Bracket, Light Fittings, Bulk Head Fittings, Tube Light Fittings Etc. And Making Good Disturbed Surfaces Of Walls, Floors Etc As Per Existing Complete All As Specified And Directed. 98 M&L For Point Wiring For One Light / Celing Fan / Exhaust Fan Point / Bell Point, Controlled By One Switch 5 Amp Sp One-Way Complete With 1.5 Sq Mm ( Nominal Area ) Pvc Insulated, Unsheathed And Multi Strand Copper Conductor Frlsh Cable ( Isi Marked ) Drawn Into And Including Pvc Concealed Conduit ( Medium Quality ) And Conduit Fittings Including 1.5 Sq Mm Pvc Insulated Unsheathed And Multi Stranded Copper Conductor Frlsh Cable As Earth Wire To Common Earth And Connecting To Earth Dolly Including Ms Sunken Box Covered With 3Mm Thick Bakelite Laminated “Hylem Or Philips“ Sheet Top Cover And Machine Made Brass Screw And Washers Etc Complete All As Specified And As Directed Notes;- ( I ) For Internal Wiring Colour To Be Used As Per Ie Rule For Phase - Red / Yellow / Blue, Neutral- Black And Earth- Green ( Ii ) Quoted Rate Shall Deemed To Be Included For Making Good Of Disturbed Surfaces With And Including M&L For Applyibg Finishes To Match With Existing Surfaces, ( Iii ) Switch / Socket To Be Measured And Paid Separately. 99 All As Per Item No. 3.02 Here-In-Before But Wiring For One 3 Pin 6 Amps Socket Outlet Point On The Same Board, Controlled By Other Switch Complete All As Specified And Directed. 100 All As Per Item No. 3.02 Here-In-Before But Wiring For One 3 Pin Socket Outlet 6 Amps Independent Board. 101 All As Per Item No. 3.02 Here-In-Before But Controlled By ( Two ) 2 Way Switch, Complete All As Specified And As Directed. 102 All As Per Item No 3.02Here-In-Before But With 2.5 Sqmm Size Cable Multi Stranded Frlsh Copper Wire Unsheathed For One 3 Pin Socket Outlet 16 Amp On Independent Board And Including2.5 Sqmm Multi Stranded Copper Conductor Frlsh Cable As Earth Continuity Wireconnecting To Common Earth Dolly Completed All As Specified And As Directed.Note :- Sunken Boxes, Frame, Plate Etc Shall Be Included In The Quoted Rate. 103 S & F Of Switch Piano Flush Type Single Pole One-Way 6 Ampere Complete All As Specified And As Directed. 104 S & F Of Switch Piano Flush Type Single Pole Two-Way 6 Ampere Complete All As Specified And As Directed. 105 S & F Of Switch Piano Flush Type Single Pole One-Way 16 Ampere Complete All As Specified And As Directed. 106 S & F Of 6 Ampere Socket Outlet Flush Type, Multi Purpose Suitable For 2 And 3 Pins ( Total 5 Pins ) Complete All As Specified And As Directed. 107 S & F Of Socket Outlet Two-In-One, 3 Pin Each Suitable For 6 And 16 Ampere Flush Type With Shuttered Complete All As Specified And As Directed. 108 S & F Of Ceiling Rose, Surface Bakelite, 65 X 50 Mm, 3 Terminals Complete All As Specified And As Directed. 109 S&F Of Lamp Holder Pvc / Polycorbonate Type Insulated Body With Back Plate Suitable For Batten Fitting / Angle Fitting Completeall As Specified And As Directed. 110 S&F Led Tube Light Fitting 1X20 Watts ( Lumeno Model Ofhavells Or Equivalent Model Of Make Specified Here-In-After ) With Pvc Insulatedflexible Copper Cable From Ceiling Rose To Tube Light Fitting Complete All As Per Specified And As Directed. 111 S & F1 X 10 Watt Led Bulk Head Luminaires Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Of 230 Volts, 50Hzcomplete All As Specified And As Directed. 112 S & F Callbell Ding Dong Type Ac 230 Volt Single Pole Fixed Over With And Including Pvc Rectangular Block Of Size 175Mm X100mmx50mmcomplete All As Specified And As Directed. 113 S&F Of Bell Push, Flush Type, 5 Amperecomplete All As Specified And As Dircted. 114 S & F Stepped Type Electronic Fan Regulator Flush Type On The Existingphenolic Laminated Sheet Etc. As Reqd Heavy Duty 230 Voltscomplete All As Specified And Dircted. 115 Supply And Fixing Led Tube Light Surface Mounting 10 Watt 2 Feet Led Light Suitable For Mirror Light With Milky Diffuser Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Of 230 Volts, 50Hz Complete All As Specified And Directed. 116 M& L For Sub Main Wiring With Two Single Core 6 Sqmm ( Nominal Area ) Stranded Copper Conductor Frlsh Pvc Insulated And Unsheathed Cable Drawn In And Including Non Metalic Pvc Regid Conduit Medium Grade Of Suitable Size With All Standard Fittings, Concealed, Including One Run Of Continuous Pvc Insulated Stranded Copper Conductorfrlsh Cable 6 Sqmm ( Nominal Area ) For Earth Continuty, Including Taking Out And Removal Of Old Sub Main Wiring Complete All As Specified And As Directed. ( Note :- 2 Runs Of 6Sqmm Copper Conductor Phase And Neutral And One Run Of Same Size Earth Wire Including One Run Of Pvc Conduct With Cutting, Chasing & Making Good Shall Be Measured As One Unit Length ) 117 M & L For Vertical Type Sheet Steel Enclouser Distribution Boards, Double Door Factory Made3 Phase 415 Volts 4 Way With 200 Amps Rating Copper Bus Bar Of Suitable Size And Pvc Insulatedcopper Jumpers From The Mccb To The Out Going Circuits ( Oneincoming Mccb And 12 Outgoing Mcbs Circuits ) Comprising Of 3 Phase 4 Wireof Suitable Rating Includingmccb 160 Amps, 25 Ka, Tp, 415 Volts, 50 Hz = 01 No. And 12 Nos Mcbs 6-32 Amps, Complete All As Specified And As Directed. 118 S & F Sheet Metal Enclosure For Dbs ( Double Door Type ) When Mcbs To Be Used Single Pole And Neutral 8 Ways Including Blanking Plate As Required With 200 Amps Rated Bus Bar, 240 Volts Fixed Sunk / Flush To The Wall Or Niche Complete All As Specified And As Directed Including Necessary Brick Work And Plaster To Match With The Existing Surface Complete All As Specified And As Directed. 119 S & F Mcb Dp, 240 Volts, Ac, B Curve, 10 Ka, 40 Amps ( 10 Ka B Rupturing Capacity ) Complete All As Specified And As Directed 120 S & F Mcb Single Pole, 240 Volts, Ac, B Curve, 10 Ka, 6 To 32 Amps ( 10 Ka B Rupturing Capacity ) Complete All As Specified And As Directed 121 S &F Ledstreet Light / Security Light Luminaries Fitting 1X35 Watt Led Includingfixing On Existing Bracket Made Out Of Gi Pipe Light Grade 32 Mm Dia 1.20 M Long Bent To Shape With Suitable Size Mild Steel Clamps Of Size 50 X 6Mm With Nut, Bolt, & Washers As Required At Site For Fixing Of Street Light On Lt Poles / Wall Including Making Connection With Pvc Insulated 3 Single Core Of 1.5 Sqmm Size Multistranded Copper Conductor Cable Complete All As Specified And As Directed. 122 M&L For Earthing Complete With Gi Earth Plate Electrode Of Size 600Mm X 600Mm X 6Mm Thick Burried Directly In Ground Vertically ( Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level ) , With Top Edge Of Earth Plate Not Less Than 1.5 M Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15Cm Thick Packed Alternate Layers Of Charcoal Dust And Common Salt, Electrode Connections Using Galvanized Iron Strip Of Size 25Mmx4mm Thick ( Upto Body Of Equipment ) By Means Of Nuts, Bolts, Check Nuts & Gi Washers, Connected To Main Switch Board Or Main Control Board Or Test Point, Protected By Galvanized Iron Pipe Light Grade 32Mm Dia Bore, And Watering Pipe 20 Mm Bore Gi Light Grade Pipe With Funnel & Wire Mesh, Including All Necessary Excavation & Earth Work, Pcc Chamber In Pcc ( 1:2:4 ) Type B-1 & Rcc Cover, All As Shown In Electrical Plate No 3 Of Mes Schedule Part-I ( 2009 ) , Testing On Completion, Including Taking Out Old Earthing Materials And Removalcomplete All As Specified And Directed.Note ( S ) :- ( I ) Rcc Pit Cover Shall Be Pre-Cast Of Rcc ( 1:2:4 ) Type B-1, 80Mm Thick Reinforced With Xpm Not Less Than 4Kg / Sqm. ( Ii ) Pcc Chamber Shall Be Constructed 500 Mm Away From The Edge Of Earth Pit. ( Iii ) Rate Shall Include Gi Strip And Protection Pipe Of Length 7.5M, Gi Pipe Beyond 7.5M Length Required At Site Shall Be Measured And Paid Separately. ( Iv ) Earth Resistance Should Be Less Than 3 Ohm. In Case The Test Results Are Not Found Below 3 Ohm, Complete Earthing Will Be Redone Without Any Extra Cost To Govt. 123 Taking Down Existing Ceiling Fan / Exhaust Fanfor Repair & Refixing The Same At Its Old Position / Location, Including Provision Of Required Winding, Synthetic Enamel Paint By Spraying, Nuts Bolts And Fastner, Transportation Etc, Complete All As Specified And As Directed. 124 External Water Supply Work 125 Excavation In Trenches In Soft / Loose Soil Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Deep For Laying Of Cables And Foundation Of Poles Etc. And Getting Out Complete All As Spceified And As Directed. 126 Returning, Filling In Trenches ( Soil ) Including Spreading Leveling And Well Ramming In Layers Not Exc 25 Cm Thick Complete All As Specified And As Directed. 127 Removal Of Surplus Excavated Soil To A Distance Not Exc 50 Mtr And Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point Complete All As Specified And As Directed. 128 Supply & Laying In Repair Gi Pipes 40 Mm Dia Bore, Medium Grade With All Necessary Fitting, Laid In Trenches Or With Wallscomplete All As Specified And As Directed. 129 Supply & Laying In Repair Gi Pipes 25 Mm Dia, Medium Grade With All Necessary Fittings Laid In Trenches Or With Walls Complete All As Specified And As Directed. 130 Supply & Laying In Repair Gi Pipes 20 Mm Dia, Medium Grade With All Necessary Fittings Laid In Trenches Or With Walls Complete All As Specified And Directed. 131 S&F In Repair Gun Metal Globe / Gate / Stop Valve ( Isi Marked ) With Iron Wheel Head Screwed Both Ends For Iron Pipe Of 40Mm Bore Complete All As Specified And As Directed. 132 S&F In Repair Gun Metal Globe / Gate / Stop Valve ( Isi Marked ) With Iron Wheel Head Screwed Both Ends For Iron Pipe Of 25Mm Bore Complete All As Specified And As Directed. 133 S&F In Repair Gun Metal Globe / Gate / Stop Valve ( Isi Marked ) With Iron Wheel Head Screwed Both Ends For Iron Pipe Of 20Mm Borecomplete All As Specified And As Directed. 134 Drilling And Tapping Cast Iron Water Mains ( In Position ) For Branch Connections Of Internal Dia 20 Mm Including S&F Brass Ferrule For Branch Connection Complete All As Specified And As Directed. 135 Note: The Total Amount Shall Subject To Adjustment Of Credit Of Rs. 218487.00 For Old Materials As Per Schedule Of Credit.