Tender For Repairs To Type - B Quarters For Cat-Ii Trainees At Hwpm Colony.; 1 Supplying All Labour, Tools, Tackles Etc., For Demolishing / Dismantling Of Water Closet Pans ( Iwc / Owc ) And Handing Over The Serviceable Materials To The Sectional Stores And Disposal Of Unserviceable Material To The Dumping Yard Etc., All Complete As Per Specifications And As Directed By The Engineer Incharge. 2 Demolishingbrick Masonry / Concrete / Rr Masonry Work Including Removing And Disposing The Dismantled Material At Designated Places And Stacking Of Serviceable Materials Etc., All Completeas Per Specification And Asdirectedby The Engineer. 3 Brick Work 4 Concrete 5 Supplying All Labour, Tools, Tackles Etc., For Dismantling Of Tile Flooring / Skirting / Cement Concrete Manually Or Mechanially Including Disposal Of Material To The Dumping Yard Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 6 Providing Required Men & Materials For Earth Work In Surface Excavation In All Kinds Of Soil Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Upto 2.0 Km And Lift Upto 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed, Complete As Per Specifications And As Directed By Engineer In Charge. 7 Earth Work Excavation In All Type Of Soils Up To A Depth Not Exceeding 1.50 Meters From Original Ground Level Including De-Watering Wherever Required And Disposal Of Excavated Earth To Dumping Yard Or Any Designated Place Within The Colony With All Leads And Lifts, Including Leveling And Dressing Of Disposed Earth Etc., All Complete As Per Drawings, Specifications And As Directed By The Engineer In Charge. 8 Supplying All Tools, Tackles, Men & Materials For Disposing All Types Of Debris In And Around The Quarters Into The Dumping Yard Etc., All Complete As Directedby The Engineer-In-Charge. 9 Supplying All Labour, Tools, Tackles Etc., For Dismantling Of Doors / Windows / Ventialtors ( Steel / Wood ) Shutters & Frames Including Chowkhats, Holdfasts Etc., Handing Over Of Serviceable Material To The Departmental Stores, Disposal Of Debris To The Dumping Yard Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 10 Supplying All Labour, Tools, Tackles Etc., For Removing Of Filled Sand From The Sunken Slabs And Disposal Of The Same With In The Colony Premises, Location As Shown By The Engineer Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 11 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : ( A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. ( B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours.The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry.Including Replacing Of C.I. Pipes With Upvc Pipes ( Upvc Pipe Will Be Paid In Relevant Item ) Preparation Of Surfaces Joints, Curing Etc., Allcomplete As Perspecifications And As Directed By The Engineer In Charge. 12 Supplying And Filling Of Good Quality River Sand Inside The Sunken Laid To Slope Including Consolidating The Same With All Leads And Lifts Etc., All Complete As Perspecifications And As Directed By Theengineer In Chaarge. 13 Supplying And Fixing 110Mm Dia Upvc Uv Stabilised Soil / Waste Quality Pipes And Fittings ( Swr ) For Soil, Waste, Vent, Antisyphonege, Hvac Waste Pipe And Rainwater Pipe Lines With Single Socketed Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, Consisting Following Items Of Work:-I ) Supplying Upvc Uv-Stabilised Soil / Wastepipe As Per Is:13592 Type A And Is:14735 Grade-Bfittings Of Supreme Make ( Fittings Will Be Measured As Part Of The Line By Linear Measurement Along The Pipe Line; And No Separate Payment Is Made. No Claim Whatsoever Will Be Entertained In This Regard ) . 14 Ii ) Laying The Pipe Below Floor / Ground To Proper Slope And Gradient For Making Connections Of Soil Pipe Line With Inspection Chamber Or Manhole, Waste Water Connection With Gully Trap Chamber Including The Cost Of Cement Mortar, Cement Concrete, Waterproofing Compound Etc.Iii ) Jointing The Pipe With Solvent Cement & Rubber Ring Gasket With Making Holes In Walls / Floor Grooving And Redoing The Same And Brick Support Etc. Giving Water-Tightness Test For The Pipes Laid As Per Codal Provisions. Providing Ring Joint Pipes At Verticals And Solvent Cement Jointed Pipes At Consealed Locations. Iv ) Necessary Cutting To The Required Length Including Short Pieces, Fittings With & Withoutdoor, Assorted Fittings Such As Plugs, Tees, Couplers, Reducers, Cross Tees, Reducing Tees, Elbows, Bends, Cleaning Pipe, Single & Double Y, Vent Cowl, Gaskets, Offsets Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 15 Providing And Fixingupvc Self Cleaning Floor Trap / Nahani Trap Of Size 100Mm Inlet And 100Mm Outlet Having Not Less Than 40 Mm Effective Water Seal, Removing The Old Trap And Fixing The New Trap In Position And Connecting To The Existing Waste Water Lines With Suitable Specials As May Be Required Withcement Solvent / As Per ManufacturerS Recommandation, Embedding The Trap In Cement Concrete 1:2:4 To Correct Level And Gradient, Providing And Fixing 200 X 200 Mm Size Top Tile With Central Strainer & Flat Cover / Flush Strainer, Closing The Side Inlets With Plugs If Required Etc. All Complete As Per Specification And As Directed By Engineer In Charge. 16 Providing And Fixing G.I Pipes Of Class : B Of Approved Make With All Fittings, Tools And Tackles, Manpower, Materials Including Cutting, Threading, Jointing With Hempyarn, White Lead, Teflon Tape, Fixing In Walls / Trenches Using Clamps, Pipe Supports, Hangers, Screws And Making Good The Walls, Painting With Two Coats Of Biiumastic Paint To The Concealed Pipe And Synthetic Enamel Paint For Exposed Portions Etc., Including All Specials & Fixtures Required At Site Etc., All Complete As Per Specification And As Directed By The Engineer In Charge. 17 15Mm Dia 18 20Mm Dia 19 Providing And Fixing White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests With 100 Mm Upvc P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures ( Hindware / Parryware / Cera Or Equivalent Approved Make ) Complete, Including Cutting And Making Good The Walls And Floors Wherever Requiredall Complete As Per Specifications And As Directed By The Engineer In Charge. 20 Providing And Fixing White Vitreous China Flat Back Wash Basin Of Size 550 X 400 Mm ( Hindware / Parryware / Cera Or Equivalent Approved Make ) With C.I. Brackets / Rack Bolts, 15 Mm C.P. Brass Pillar Tap, 32 Mm C.P. Brass Waste Coupling Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 21 Providing And Fixing 15Mm Dia C.P. Brass Stop Cock ( Concealed / Exposed ) Of Standard Design And Of Approved Make Conforming To Is : 8931 Including Cutting The Wall And Making Good After Fixing Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 22 Providing And Fixing 15 Mm Nominal Bore C.P Brass Long Nose Bib Cock Of Approved Quality Conforming To Is 8931 And Weighing Not Less Than 400 Gms As Per Specifications And As Directed By The Engineer In Charge. 23 Providing And Fixing Oval Shape 450X350 Mm ( Outer Dimensions ) Mirror Of Superior Glass ( Of Approved Quality ) With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backingetc., Complete All As Per Specifications, Drawings And As Directed By The Engineer In Charge. 24 Providing And Fixing 15 Mm Nominal Bore C.P Brass Pillar Cock Of Approved Quality Conforming To Is 8931 And Weighing Not Less Than 400 Gms As Per Specifications And As Directed By The Engineer In Charge. 25 Providing And Fixing 600 Mm Long Ptmt Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms.Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour Etc., All Complete As Per Specification And As Directed By The Engineer In Charge. 26 Providing And Fixing 150Mm Diameter / 150 X 150Mm Stainless Steel Shower Rose With 15Mm Diameter Inlet Provision Of Approved Make Etc., All Complete As Per The Manufacturer Specifications And As Directed By The Engineer In Charge. 27 Providing And Fixing 600Mm Cast Brass Coat Hook Consist Of 6 NoS Of Hooks Of Approved Brand & Make Including All Necessary Ss Screws And Caps Etc. Complete All As Per Design Approved By Engineer-In-Charge. 28 Providing And Laying 1St Quality Anti Skid Ceramicfloor Tilesof Size 300 X 300Mm ( Thickness To Be Specified By Manufacturer ) Conforming To Is 15622 With Isi Mark Of Approved Make ( Somany / Johnson / Kajaria Or Equivalent Approved Make ) , In All Colours Except White, Ivory, Grey, Fume Red And Brown Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1Cement: 4 Coarse Sand ) In Floorsjoint With Grey Cement Slurry @ 3.3Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigments Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 29 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is:15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make And Shade ( Somany / Johnson / Kajaria Or Equivalent Approved Make ) , In All Colours , Shadesof Any Size As Approved By Engineer, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 30 Providing And Applying One Or More Coats Of Distemper With 1St Quality Acrylic Distemper, Having Voc ( Volatile Organic Compound ) Content Less Than 50 Grams / Litre, Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour Of Asian / Nerolac Or Approved Make And Brand On Old Surface Including Surface Preparation, Cleaning Of Surface, Removing Old Loose Paint, Removal Of Nails Etc., Filling Of The Holes And Cracks With Approved Crack Filler, Sand Papering, Removal Of Cob Webs, Cleaning Etc., Complete Including All Materials, Labour, Transport, Scaffolding As And When Required And Cleaning Of The Rooms After Completion Of Work Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 31 Providing And Fixing 30 Mm Thick Isi Marked Non Decorative Type Flush Door Shutters Of Size ~ 900Mm X2100mm Conforming To Is : 2202 ( Part I ) Of Approved Make, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters, Minimum 75Mm Wide Lipping On Both Sides Including Fixing With Isi Marked Stainless Steel Butt Hinges With Necessary Screws, Two Coats Of Synthetic Enamel Paint Of Approved Shade Over A Coat Of Wood Primer And Fixing Of Ms Aldrop Of Size 250Mm X 16Mm - 1No, Ms Latch 250Mm X 20Mm X 6Mm - 1 No, Ms Door Handles Of 125Mm Size - 2 NoS, Tower Bolt Of Size 200Mm X 10Mm - 1No, Brass Door Stopper Of Good Quality -1No, 2 Inch Plastic Door Bush -1No Etc., Complete All As Per Specifications And As Directed By The Engineer In Charge. 32 Providing And Fixing Factory Made 30 Mm Thick Non Decorative Finish Door Shutter Made Of Solid Pvc Foam Profile. The Styles & Rails Shall Be Of Size 75 Mm X 30 Mm Having Wall Thickness 5 Mm. The Styles, Top & Bottom Rails Shall Have One Side Wall Thickness Of 15 Mm Integrally Extruded On The Hinge Side Of The Profile For Better Screw Holding Power. The Styles And Rails Shall Be Reinforced With M.S. Tubes Of Size 33 Mm X 17 Mmx 1 Mm, Painted With Primer, All Four Corners Of Reinforcement To Be Welded Or Sealed. Solid Pvc Extruded Bidding ( Push Fit Type ) Will Be Set Inside The Styles And The Rails With A Cavity, To Receive Single Piece Extruded 5Mm Pvc Sheet As Panel. The Styles And Rails Will Be Mitred Cut And Joint With The Help Of Pvc Solvent Cement & Self Driven Self Tapping Screws. Single Piece Extruded Solid Pvc Lock Rail Of Size 100 Mm X 30 Mm With Wall Thickness 5 Mm & 15 Mm Integrally Extruded In The Middle Of The Lock Rail & Fixed With Styles With The Help Of Pvc Solvent Cement & Self Driven Self Tapping Screws Of Size 100Mm X 8 Mm Including Providing & Fixing Of Aluminium Grade Ac 10 As Per Is : 1868 Aldrop Of Size 250Mm X 16Mm - 1No, Latch 250Mm X 20Mm X 6Mm - 1 No And Door Handles Of 125Mm Size - 2 NoS, Powder Coated Ms Tower Bolt Of Size 200Mm X 10Mm - 1No Etc., Complete All As Per ManufacturerS Specifications And Direction Of Engineer-In-Charge. 33 Providing And Fixing In Position Of 20Mm Thick Cement Bonded Particle Board ( Bison Board ) In The Cupboard Shelves As Per The Existing Patterns And Arrangement As Directed By The Engineer Including Cutting To Required Size With Power Cutter, Supply And Fixing Necessary Nuts And Bolts, Making The Edges Smooth, Making Holes To Board For Fixing Nuts & Bolts, Applying Two Or More Coats Of Exterior Emulsion Paint Like Trump Or Equivalent Over A Coat Of Cement Primer On Both Sides Including Removing Of Old Damaged Cupboard Planks And Handing Over The Useful Material At Sectional Stores And Disposing The Waste Material To The Dumping Yard Etc. Complete As Per Drawings, Specifications And As Directed By The Engineer 34 Providing And Fixing Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15 ) Work For Ventilators With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Including Providing & Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws Etc., All Complete As Per Architectural Drawings And The Directions Of Engineer In Charge. ( Glazing / Panelling To Be Paid For Separately ) Note : Repair Works Shall Be Guaranteed For One Year For Smooth Operation. 35 Supplying And Fixing Glazing In Aluminium Windows And Ventilator Shutters And Partitions Etc., With Float Glass Panes Of 5Mm Thick Of Weight Not Less Than 12.50Kg / Sqm With Epdm Rubber / Neoprene Gasket Etc. All Complete As Per Specifications And As Directed By The Engineer. 36 Providing And Fixing In Position Fly Proof Stainless Steel Grade 304 Wire Gauge To The Windows & Ventilators With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50Mm Including Fixing To The Walls With 25Mm Aluminium Flat / Beading Etc. All Complete As Per Specification And As Directed By The Engineer. 37 Providing & Fixing 7 Lever ( Rim Lock ) Chromium Plated Brass Night Latch ( Both Key Part & Back Part ) For Inside Opening Of Doors Of Godrej Make Model No 8261 Or Equivalent With Isi Mark Is 1019 Suitable For Door Thickness 35-45Mm Etc., All Complete As Per The Manufacturer Specifications And As Directed By The Engineer In Charge. 38 Supplying, Fabricating And Fixing Structural Steel Work In Builtup Sections For Frames Of Doors & Windows, Window Shutters, Guard Bars And Grills Etc., Including Cutting, Welding, Hosting, Fixing In Position And Applying Two Coats Of Enamel Painting Of Approved Make Viz. Asian / Nerolac / Berger Over A Priming Coat Of Steel Primer Of Approved Make Etc., All Complete As Per Drawings, Specification And As Directedby The Engineer-In-Charge. ( Fabrication With Ms Plates, Angles, Flats, Channels, Squarebars Etc., ) 39 Providing And Laying 15Mm Thick Cement Plaster In Cement Mortar 1:4 ( 1 Cement : 4 Fine Sand ) Proportion Over Brick / Rr Masonry / Concrete Walls, Floors And Other Surfaces Including Providing And Mixing Approved Water Proof Compound In The Proportion Recommended By The Manufacturer, Raking Of Joints, Hacking The Concrete Surfaces, Scaffolding Where Necessary, Curing Etc., All Complete As Perdrawings, Specifica-Tions And As Directed By The Engineer. 40 Providing And Fixing Of Pre Cast Reinforced Cement Concretecovers / Slabs Including The Cost Of Reinforcement With 8Mm Dia Tmt Bars @ 200Mm C / C, Cement Is Of Acc / Ultratech / Birla A1 Or Any Other Approved Make, Includingshuttering, Finishing With Neat Cement Punning On Exposed Surface With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 12.50Mm Nominal Size ) Including Transporting, Placing, Compacting, Curing Etc., All Complete As Per Drawings, Specification And As Directed By The Engineer. 41 Construction Of Gully Chambers Of Size 300 X 300 X 300 With Half Brick Masonry Over A Bedding Of 100Mm Thick Pcc 1:4:8 Including 15Mm Thick Plastering Inside And Out Side, Providing And Fixing New Gully Trap Of Size 100 X 100Mm Including 50Mm Thick Precast Cover Of Size 530 X 530Mm With Welded Mesh 50 X 50 X 3Mm Etc., Complete Including Dismantling Of Old Damaged Chamber, Stacking And Handing Over Ofserviceable Materials In Sectional Stores, Disposing Of Unserviceable Materials Within A Lead Of 50 Mtrs Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge. 42 Constructing Brick Masonry Chamber For Underground C.I Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) C.I. Cover With Frame ( Light Duty ) 455 X 610 Mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) , R.C.C. Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) , Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) , Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bedoncrete Etc. Complete As Per Standard Design:Inside Dimensions 455 X 610 Mm And 45 Cm Deep All Complete As Per Specifications And As Directed By The Engineer In Charge. 43 Constructing Brick Masonry Circular Type Manhole 0.91 M Internal Dia At Bottom And 0.56M Dia At Top In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Inside Cement Plaster 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Concrete 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement, All Complete As Per Standard Design : 0.91 M Deep With Rcc Cover And Frame 560 Mm Internal Diameter, In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Including Centering, Shuttering, Erection Of Covers All Complete ( Excavation, Foot Rests And 12Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately ) As Per Specifications And As Directed By The Engineer In Charge. 44 Providing Hoe ( Excavator Cum Dozer ) / Jcb For Miscellanbeous Works At Different Locations As And When Required Including All Operational Cost To Complete The Job In All Respects As Per Specifications And As Directed By The Engineer. 45 Cutting V Groove 10 Mm Wide 15Mm Deep Along The Cracks Found In Construction Joints Or In Rcc Wall Surfaces, Cracks, Joints Between Rcc Lintel Cum Sunshade And Wall; Rcc Beam / Wall Junction ( On External Side ) Etc.; Cleaining The Surface To Make The Area Dust Free Etc. Complete As Per Specifications, And As Directed By The Engineer. 46 Sealing Of Grooves And Wide Cracks With Epoxy Putty Pidifoxy Ep Of Dr. Fixit / Sika / Huntsman Or Equivalant Make, As Per Site Requirements And Manufacturers Specifications Over Prepared Surfaces; By Pushing In Grout In Paste Form And Coving 20 Mm X 20 Mm After Applying A Coat Of Zycosil & Zycoprime Or Equivalent Solutions Etc Complete At All Levels And As Directed By The Engineer. 47 Providing All Tools, Tackles, Men And Materials For Applying Average 15 Mm Thick Plastering With Rendering At All Levels On Rcc Columns, Beams, Slabs And Other Areas With Ready To Use One Part Polymer Modified Cement Mortar Rendroc S Or S2 Of Foscroc Chemicalsor Equivalent Upto A Height Of 15M ( Scaffolding Cost Will Be Paid Seperately ) , Chipping Out Theloose Concrete Spallings, Hacking The Concrete Surface For Bonding , Surface Preparation, Applying Nito Zink Primer On Exposed Reinforcement Bars And Curing With Nito Bond Ar Or Equivalent On The Concrete / Plastered Surface Areas As Per Manufacturers Specifications And As Directed By The Engineer In Charge. ( Note: Desirebale Properites Of The Mortor Will Be High And Early Compresivestrength, Low Permiability, And High Resistance To Chemical Attack ) . 48 Providing And Applying One Or More Coats Of Ready Mixed Synthetic Enamel Paint Of Asian / Nerolac / Berger Or Approved Make And Shade Over Old Surface Of Wood / Steel Work Including The Cost Of Scaffolding, Cleaning, Preparation Of Surfaces, Necessary Repairs To Scratches / Cracks With Putty, Arranging Safety Appliances, Insurance Coverage To Workers, At All Heights All Complete As Per Specifications And As Directed By The Engineer In Charge. 49 Providing And Applying Twoor More Coats Of Acrylic Smooth Exterior Coating Of Apex Ultima Of M / S. Asian Paints / Excel Plus Of M / S. Nerolac / Heatshield Of M / S. O.Fixit / Weathershield Max Of M / S. Ici Delux Plus Or Any Other Approved Equivalent Make And Shade Over The Plain Plastered / Sand Face / Rough Cast Plaster / Rcc Jalli / Rcc Fins At Locations As Required On Old Wall Surfaces, Applied @ 1.67 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied@ 2.20 Kg / 10 Sqm ) , Ensuring An Interval Of 4-6 Hours For Each Successive Coats, Scaffolding, Safety Appliances Insurance Coverage To Workers Etc., All Complete As Per The ManufacturerS Specification And As Directed By The Engineer In Charge. 50 Providing Required Men & Materials For Repair Of Windows Including The Cost Of Hinges, Tower Bolts, Handles And Welding If Required And Make It Ready For Servcieable With Closing & Opening Of Windows Etc., All Complete As Per Specifications And As Directed By The Engineer In Charge.