| 1 | SCHEDULE‘A’ PART- I (Addl/Alt ofOffrs Mess Bldg) |
| 2 | Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth upto 50m & lift upto 1.5m disposed soil to be levelled & nearby dressed in all kindl of soil |
| 3 | Earth work excavation in foundation trenches or drains including dressing of side and ramming of bottoms lift upto 1.5metres including getting out the excavated soil and disposal of surplus excavated soil as direction with in a lead of 50 metres Hard/Dense soil |
| 4 | Providing and laying in position cement concrete of specified grade excludinthe cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 5 | Brick work with common burnt clay FPS Non modular bricks of class design 7.5 in foundation & plinth in Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 6 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 7 | 20 mm cement plaster of mix : for external surafce1:4 (1 cement: 4 coarse sand) |
| 8 | Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately), including fixing 50x12 mm beading complete with : Second class teak wood |
| 9 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately).Second class teak wood |
| 10 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied@ 2.20kg/10 |
| 11 | SCHEDULE‘A’ PART-II (Addl/Alt of Offrs Mess Bldg Footpath) |
| 12 | Earth work in surface ( All kinds of soil) excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge. |
| 13 | Supplying, stacking, Laying, spreading and compacting at site.63 mm to 45 mm size stone aggregate at site. |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 15 | Providing and laying factory made chamfered edge, 60mm thick cement concrete paver block of M-35 grade with approved colour,design & pattern. in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 16 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand). |
| 17 | SCHEDULE‘A’ PART-III (Addl/Alt of Offrs Mess Bldg Electrification) |
| 18 | Supply and fixing of square shap solar pilliar light size 300x300 mm with 3 deffrant colour light and on/off colour change button |
| 19 | SCHEDULE‘A’ PART-IV ( Addl/Alt of ORs Mess Upgradtion of Dining hall) |
| 20 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 21 | Dismantling tile work for thickness of tiles 10 mm to 25 mm in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 22 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 23 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand). |
| 24 | Providing and laying vitrified floor tiles in size of tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 25 | Providing and fixing ISI marked 35 mm thick flush door shutters including ISI marked Stainless Steel butt hinges with necessary screws conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 26 | Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS : 14842, including top cover of 6 mm coir veneer board, nickle plated M.S. Pipe 20 mm dia. (heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. |
| 27 | Providing & fixing in position Phenol bonded Bamboowood wall cladding at all height with planks of sizes 10 mm thick, 1800 mm length (minimum) and 130 mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC), with necesasary profiled edges fixed with 40mm SS screws 5 nos in each tile to frame work made of second class teak wood of size 20x15 mm in centre of each tile and bottom and top of work height, 40x15mm placed at ends of each tile. The cladding shall be laid over backlayment of 1.00 mm thick expanded polyethylene foam of density 40kg/cum in two layers, first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge. |
| 28 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.(Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 29 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 30 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 31 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 32 | Painting with synthetic enamel paint two or more coats on new work of approved brand and manufacture to give an even shade. |
| 33 | Providing and fixing Slotted cowl (terminal guard) 100 mm dia. |
| 34 | SCHEDULE‘A’ PART-V ( Addl/Alt of ORs Mess Upgradation of Cook House) |
| 35 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.Cook House Border L = 2x(4.5+4) = 17 MtrCook House Plinth Protection L = 2x(4.5+4+0.6) = 18.20 Mtr |
| 36 | Demolishing cement concrete nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 37 | Providing and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.L = 4.5+4.0+1.50 = 10.0 Mtr |
| 38 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand). |
| 39 | Providing and fixing green granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 40 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm. |
| 41 | Providing and laying vitrified floor tiles in size of tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc complete. |
| 42 | SCHEDULE‘A’ PART-VI ( Addl/Alt of ORs Mess Electrification) |
| 43 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 44 | Material and labour for Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 45 | Supplying and drawing 3x6.00 sqmm sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 46 | Supplying and fixing metal box of 200 mm X 250 mm X 75 mm deep sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 47 | Supplying and redrawing of 3 x 4 sq. mm sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required including dismantling and making surface good etc. as required. |
| 48 | Supplying and fixing 5/6 amps switch piano type on the existing switch box/ cover including connections etc. as required. |
| 49 | Supplying and fixing 15/16 amp switch piano type on the existing switch box/ cover including connections etc. as required. |
| 50 | Supplying and fixing 5 pin 5/6 amp socket outlet on the existing switch box/ cover including connections etc. as required. |
| 51 | Supplying and fixing 6 pin 15/16 amp socket outlet piano type on the existing switch box/ cover including connections etc. as required. |
| 52 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 53 | Supplying and fixing following way, 2 + 4 way, Single door single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 54 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 55 | Supplying and fixing brass/insulated batten/ angle holder including connection etc. as required. |
| 56 | Material and labour for Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 57 | Supplying, installing on wall, testing and commissioning of 200 amps Busbar Chamber in sheet enclosure suitable for 415 volts, 50 Hz, 4 way, A.C. supply. |
| 58 | SCHEDULE‘A’ PART-VII (Addl/Alt of ORs Mess Dranage) |
| 59 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 60 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 61 | Supplying, laying and compacting stone aggreagte of size 63 mm to 45 mm for hardcore. |
| 62 | Providing and laying in position cement concrete ofgrade 1:3:6 using 40mm size stone aggregate. |
| 63 | Brick work with common burnt clay F.P.S.bricks of class designation 7.5 in drain in Cement mortar 1:6. |
| 64 | 15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4. |