Tender For Special Repair Of Building No. Ewt-1A At 114 Inf Bn ( Ta Jat ) At Fatehgarh Cantt ; 1 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From Frames ) Area Not Exceeding 1.50 Square Metre Each, Complete All As Specified And Directed. 2 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From Frames ) Area Exc 1.5 Sqm Not Exceeding 4 Square Metre Each, Complete All As Specified And Directed. 3 Dismantling Of Floor Hearth Or Wall Tiling / Kota Stone Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premisescomplete All As Specified And Directed. 4 M & L For Virified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Matchlaid Over Screed Bed Or Bedding Layer In Cm 1:4 Of 15 Mm Thick For Laying Floor Finishes Etc Complete All As Specified And Directed. 5 M & L Forglazed Ceramic Tiles In Vertical Surface 450 X 300X 7Mm Thick Coloured Tiles, Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match, 15 Mm Thick Rendering On Fair Faces Of Concrete Surface Ofverticle In Cm ( 1:4 ) Finished Even And Smooth Without Using Extra Cement Complete, Shade & Design As Approved By Eic / Ge, Incl Rubbish Off The Primises Etccomplete All As Specified And Directed. 6 M&L For Non Skid Ceramic Any Coloured / Printedtiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exc 0.06 Sqm But N, Exc 0.11 Sqm As In Floor Of Shade & Designed As Approved By Age, Set And Jointed In Neat Cement Slurry And Pointed With White Cement With Colour Pigment To Match The Colour Of Tiles, Over15 Mm Thick Screed Bed In Cement Mortar ( 1:4 ) In Floors, Etccomplete All As Specified And Directed. 7 Dismantling Of Asbestos Cement ( Corrugated, Semicorrugated, Etc. ) Sheets In Roof Coverings Etc Complete All As Specified And Directed 8 S & F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified Etc Complete All As Specified And Directed 9 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Ridge / Cladding To Wall, Fixed With Selftapping Screwscomplete All As Specified And Directed. 10 S&F Galvanised Mild Steel Wire Cloth 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm Fixed With Tinned Tackscomplete All As Specified And Directed. 11 Taking / Down Cement Plasterany Description On Brick Or Stone Work Etc Including Taking Out Joints Hacking For Key Scrubing Down With Water Complete All As Specified And Directed 12 M&L Rendering 15 Mm Thickin Cement Mortar ( 1:6 ) On Fair Faces Of Brick Work Or Concrete Surfaces To Be Finished Even And Smooth Without Using Extra Cement With And Including Complete All As Specified And Directed. 13 M & L Two Coats Of Oil Bound Distemper On New Plastered Wall Suerfaces Over A Coat Of Alkali Resistant Primer Over 3Mm Thick Wall Putty Including Preparationcomplete All As Specified And Directed. 14 M&L Rendering 15 Mm Thickin Cement Mortar ( 1:4 ) On Fair Faces Of Brick Work Or Concrete Surfaces To Be Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed . 15 M & L Fortwo Coats Of Cement Based Paintover A Coat Of Alkali Resistant Primer On New Plastered Wall Surfaces Including Preparation Complete All As Specified And Directed. 16 S & F For Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Etc Conforming To Fe 410-W ( Gde E-250 ) Quality B Complete All As Specified And Directed. 17 S & F 3 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Mitred Beads Or Oil Putty Including Glazing Clips In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. 18 S&F Mildsteel Barrel Tower Bolts 150Mm, Stove Enamelled Black, With Barrel Of Extruded Section And Fixedcomplete All As Specified. 19 S&F Mild Steel Sliding Door Bolts 250Mm, Plate Type, Stove Enamelled Black, With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, Four On Bolt Plate And Two On Staple Plate And Fixed, Complete All As Specified. 20 S&F Mild Steel Pressed Handles 125Mm Size, Oval Type, Stove Enamelled Black, Complete All As Specified. 21 S&F Butt Hinges, Medium Grade Cold Rolled Mild Steel 100 Mm Longcomplete All As Specified And Directed. 22 M&L For Cutting Holes In Brick Walls In Cement Mortar Mortar For Inserting Holdfasts And Making Good Dismantled Portion In Cement Mortar 1:3 Or Cement Concrete 1:2:4 Type B-1 Complete All As Specified And Directed. 23 S&F In Repair 15Mm Bib Tap Cast Copper Alloy ( Chromium Plated ) Isi Marked With Crutch Or Butter Fly Handle Screwed Down, Screwed For Iron Pipe Or Brass Firul And Fixedcomplete All As Specified And Directed. 24 S&Fin Repair Ptmt Grating Doom 150 Mm Dia With Waste Hole Completle All As Specified And Directed. 25 S&F Mild Steel Framed Work Of Angle Or Any Other Section ( Grade 410 - 0 Or Fe 310-0 ) As In Door And Door Frame, Gates Of Angle Frame Work Etc Including Necessary Welding Etc Complete All As Specified And Directed. 26 S&F 32 Mm Th Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sidescomplete All As Specified And Directed. 27 M & L For Preparation Of New Or Previously Untreated Surfaces Of Wood And Wood Based Surfaces Of Any Description, Over 10 Cm In Width Or Girth And Apply Two Coat Of Synthetic Enamel Paint Over A Coat Of Wood Primer Complete All As Specified And Directed. 28 M&L For Framed Work Such As Guard Bars In Steel Window Confirming To Fe-290 Gde E-165Complete All As Specified And Directed. 29 Supplied And Fixed Steel Ventilators With Top Hung Shutter Including Hinges Steel Peg Stay, Complete. 30 M&L For Two Coat Of Synthetic Enamel Paint Including Preparation Of Steel Surfacesover 10 Cm In Width Or Girth, Not Otherwise Describedcomplete All As Specified & Directed., 31 M&L For Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primerincluding Preparation Of Steel Surfacesover 10 Cm In Width Or Girth, Not Otherwise Describedcomplete All As Specified & Directed., 32 Taking Up Or Down 15 Mm Bore Dia. Gi Steel Tubing And Connection Including Cleaning For Re-Fixing Or Removing Ot Store. 33 Refixing Old Steel Tubing And Connections In New Or Old Position ( Wall, Ceilling, Floor Etc ) Bore Of Pipe 15 Mm. 34 S&F Gi Tubing Medium Grade 15 Mm Bore With All Fitting & Fixed To Wall & Ceiling Or Laid In Floorscomplete All As Specified & Directed., 35 Demolition Of Brick Work Or Stone Masonry, Built In Cement Mortar Incl All Quoins, Arches Pillars Etc All Ascomplete All As Specified & Directed., 36 M&L Of Brick Work Withsub ClassB Burnt Bricks Straight Or Curved On Planexc. 6 M Mean Radius Bult In Cm 1:6 Complete All Ascomplete All As Specified & Directed. 37 M & L Brick Work Using Old Size Bricks ( Except Brick ) Straight Or Curved On Plan Exc 6 M Mean Radius Built In Cement Mortar 1 : 6 Complete All As Specified And Directed. 38 Dismantling Of Existing Water Tank Of Any Description ( Rcc. Brickwork Or Pvc ) ( Capacity Not Exc 500 Lit ) And Removing From Site Complete All As Specified. 39 S & F Rotational Moulded Polyethylene Water Storage Tanks 500 Ltr Capacity ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Including 20 Mm Dia Ptmt Float Valve Complete All As Specified. 40 Dismantling Wall And Ceiling Boards ( Fibre, Pulp, Insulation, Etc. ) Or Insulation Boards / Slabs / Blankets, Any Thickness, Including Cover Fillets 41 Providing And Fixingfalse Ceiling At All Heights With Grg ( Glass Fibre Reinforced Gypsum ) False Ceiling Tiles With Fully Perforated 12Mm Thick Micro Tegular Edged Or 10Mm Thick Square Edged Grg False Ceiling Tiles Of Size 595 X 595Mm Of Approved Texture, Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 ( Part 4 ) - 1970 And Light Reflectance Of 85% ( Minimum ) To Be Laid In True Orizontal Level Suspended On Interlocking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick ( Galvanized @ 120 Grams Per Sqm Including Both Sides ) Cocmprising Of Main T Runners Of Size 15 X 32Mm Of Length 3000Mm, Cross - T Of Size 15X32mm Of Length 1200Mm And Secondary Intermediate Cross-T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600X600mm, Suspended From Ceiling Using Galvanized Mild Steel Items ( Galvanizing @ 80 Grams Per Sqm ) I.E. 50Mm Long, 8Mm Outer Diameter M-6 Dash Fastners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000Mm Length And L- Shape Level Adjuster Of Size 85X25x2mm. Galvanised Iron Perimeter Wall Angle Of Size 24 X 24X0.40Mm Of Length 3000 Mm To E Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 450 Mm Center To Center And 40Mm Long Dry Wall Wood Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 42 S & F Solid Pvc Wall Lining Consisting Of 5Mm Thick Single Side Prelam Pvc Sheet Used Instead Of Plain Colour Sheetinclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specifications And Drawing 43 S & Fanodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified 44 S & F For Anodised Aluminium Door Shutters, Aluminium Section Including Necessary Joining Cleats, Glazing Clips, Ruber Neoprene Packing, Handles 2 Nos In Each Leaf, Stainless Steel Hinges - 04 Nos On Each Leaf, Anodised Aluminum Snap Beading Screws Etc. Complete All As Specified. 45 S & F For Anodised Aluminium Window And Ventilator Shutters, Fixed Type Without Sash Bar, Aluminium Section Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Stainless Steel Butt Hinges-03 Nos On Each Leaf And 02 Nos Handles On Each Leaf Etc. Complete All As Specified 46 S & F For Aluminium Anodised 75 X 75Mm Size Diamond Pattern 4Mm Thick Grill Including F / H Section Frame Fixed With Cadmium Plated Screw To Window Complete All As Specified And Directed. 47 M&L For 4.8 To 5.5Mm Thick Glass Ordinary Quality, Glazing Or Black With Aluminum Beeding And Gasket To Aluminum Frameworkin Squareexc 0.50 Sqm Ineach Pane In Repair Complete All As Specified. 48 S & F Door Closer Aluminium ( Diecast ) Body Hydraulically Regulated, Designation No. 3, Universal Type, Suitable For Door Shutters Of 851 To 1000 Mm In Width And Of Weight Between 61 To 80 Kg And Fixed 49 S & F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Palin Colour Pvc Sheet Reinforced With Ms Square Tube, Suppling And Fixing In Opening As Per Specification And Drawing. 50 S & F Factory Made Solid Panel Pvc Door Shutter 30Mm Thick ( Style ) Consisting Of Frame Made Out Of Ms Tubes For Top & Bottom Rails. M S Frame Shall Be Covered With Heat Moulded Plain Colour Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock And Bottom Rail On Either Side & As Gap Insert For Tip Rail & Bottorm Rails; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Weloded / Seated To The Stiles & Rails With Suitable Pvc Sheet Beading And Joined Together With Solvent Cement. Suppling And Fixing In The Frame At Site As Per Specification & Drawing. 51 S & F In Repairvitreous China Urinal, Half Stall Type, White ) , With Grating And Union For Discharge Pipe, Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe. ( Exclusive Of Fixing Supply Pipe To Flushing Cistern, Trap And Waste Pipe ) Etc Complete All As Specified And Directed. 52 S&F In Repair Vitreous China Wash Basin, White, Flat Back, Size 550X400mm Including Brackets, Cutting For And Pinning In Ends Of Brackets , 32 Mm Pvc Waste Pipe, 32 Mm Ptmt Waste Coupling And 15 Mm Dia Pillar Taps Fancy Type Chromium Plated Complete All As Specified And Directed 53 M & L For 32Mm Bottle Trap Of Ptmt Fixed To Wash Hand Basin Having Minimum Waterseal Of 25Mm . ( Minimum Weight 32Mm-260Gms / 40Mm-270 Gms ) Etc Complete All As Specified And Direted. 54 S& F In Repair Gun Metal Glove Or Gate Valves. With Iron Wheel Head, Screwed Both Ends For 20 Mm Iron Pipe And Fixed Screws Complete All As Specified And Directed 55 S&F In Repair Low Level Flushing System Pvc Valveless Syphonic Action Type, 10 Ltrs Capacity White, With Inlet, Ball Float And Handle Including Brackets Complete All As Specified And Directed. 56 S&Fin Repairconclead Type Stop Valves Angle, Facy Type , Screwed Down For Iron Pipe And Fixed To 15Mm Bore Pipe , Complete All As Specified And Directed. 57 S&Fin Repair Chromium Plated Bib Tap Chromium Plated Fancy Type Screwed Down For Iron Pipe And Fixed To 15Mm Bore Pipe Complete All As Specified And Directed. 58 S&Fin Repair Stop Valves Fancy Type Chromium Plated, Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed 59 S&F S&Fin Repair Pvc Connection 15Mm Size With Ptmt Nuts Of Length 450Mm Etc Complete All As Specified And Directed. 60 S&Fin Repairf 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cupwashers Complete All As Specified And Directed. 61 S&Fin Repair For Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long. 62 S&Fin Repair Soap Dish, Any Type, Fixed To Plugs With Chromium Platedbrass Screws 63 S&Fin Repair Brass Chromium Plated, Tubular Towel Rail, 20Mm Dia, D Type, 60Cm Long Between Flanges Complete All As Specified And Directed. 64 S&Fin Repair Vitreous China Wash Down Water Closet Pan Semi-Pedastel Pattern ( Anglo Indian Type ) White In Colour Connected With And Includings Or P Trap Including Water Closet Seat , Black , Closed Patternwith Flat Bottom And Cover And Ms Chromium Plated Hinging Devicecomplete All As Specified And Directed. 65 M&L For75 Mm Dia. Cast Iron Floor Trap, With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete Type B-1 ( 1:2:4 ) Including Dismantling Completeall As Specified And Directed . 66 Dismantling Framed Timber Scantlings 40 Sq. Cm And Over In Section, In Any Positioncompleteall As Specified And Directed . 67 Dismantling Framed Timber Scantlings As In Fillets, Rails, Posts, Rafters, Purlins, Etc. Under 40 Sq. Cm In Section Completeall As Specified And Directed . 68 S & F Clean Sawn Second Class Hard-Wood In Scantlings Including Jointing, Erection Etc Completeall As Specified And Directed.. 69 Taking Down Copper / Aluminium Point Wiring Of Any Description And Any Position ( Light, Fan, Socket Or Power Point ) Complete, Including Fixture And Fittings Such Asswitches, Socket, Ceiling Rose, Lamp Holder, Pendants, Bracket And Regulator Etc And Removing Material From Site Including Making Good Disturbed Surface To Match With The Existing Surface Complete All As Specified And As Directed . 70 Taking Down Aluminium / Copper Sub Main Wiring And Making Good Disturbed Surfaces To Match With The Existing Surface Roof / Wall / Floor Complete All As Specified And As Directed . 71 M&L For Point Wiring Of Light / Fan / Exhaust Fan Point Controlled By One Switch With 1100 Volt Grade Pvc Insulated And Unsheathed 1.5 Sq Mm ( Frls ) Multistranded Copper Conductor Cable With Continuous Earth Wire Of 1.5 Sq Mm ( Frls ) Multistrandedcopper Conductor Cable Pvc Insulated And Unsheathed, Drawn In & Including Concealedpvc Rigid Conduit Medium Grade With Fittings ( Isi Marked ) Not Less Than 20 Mm Dia & 1.6 Mm Thick Sunken Pressed Steelgalvanised Terminal Boxes With Top Cover Isi Marked Plastic Laminated Hylam Sheetfor Housing / Fixingswitches Etc Complete All As Specified And Directed For The Following-Note- ( I ) The Quoted Rete Is Deemed To Be Included For The Chases Cutting. ( Ii ) Cutting Chases For Concealed Shall Be Made Good Using Cm 1:4 And Surface Finished To Match The Existing Surface & Colour. 72 ….....Ditto As Above But For One 5 Pin 5 Amp Switch Socket Combination Point On An Independent Board….Ditto.. 73 ….....Ditto As Above But For One 5 Pin 5 Amp Switch Socketpoint Controlled By One Switch On Same Board.….Ditto.. 74 ….....Ditto As Above But For One 16 Amp 6 Pin Switch Socket Combination Independent With4 Sqmm Frlsunsheathed Copper Conductor Single Core Multistranded ….Ditto.. 75 S&F Modular Switch 1 Way 6A, 1 Module Complete All As Specified And Directed. 76 S&F Modular Switch 1 Way 16A, 1 Module Complete All As Specified And Directed. 77 S&F Socket, 6A - 2 / 3 Pin Combined 2 Module Complete All As Specified And Directed. 78 S&F Socket 16A - 2 / 3 Pin Combined 2 Module Complete All As Specified And Directed. 79 S&F White Cover Plate With Frame, 1Module Complete All As Specified And Directed. 80 S&F White Cover Plate With Frame, 4Modulecomplete All As Specified And Directed. 81 S&F White Cover Plate With Frame, 8 Module Complete All As Specified And Directed. 82 S & F Modular Electronic Fan Step Regulator, 120W - 2 Module Complete All As Specified And Directed 83 S & F Ceiling Rose Pvc / Poly Carbonate Isolated Body Three Terminal Ac 230 Volts Complete All As Specified And Directed. 84 M&L For Lamp Holder Pvc / Polycarbonate Type Insulated Body With Back Plate Angle Type For Batten Fittings Incl Led Lamp Of 12 Watt And Colour Temp 6500K Suitable For Fix In Angle Holder Complete All As Specified And Directed. 85 Supply And Fixing In Replacementvtpn Dbsuitable For Mounting Mccb As Incomer Of Rating 100 Ampvertical Distribution Board 4 Way With Suitablerated Bus Bar Having Ip-43 Protection And Double Metal Door Concealed In Wall Including Connection With Aluminium Thimbles As Required Complete All As Specified. 86 Supply And Fixing In Replacementmcb Distribution Board Spn 240 Volt8 Way With 200 Amp Rated Bus Bar Having Ip-43 Protection And Double Metal Door Concealed In Wall Including Connection With Copper Thimbles As Required Complete All As Specified. 87 S&F Of Mccb 100 Amp, 16Ka, 4 Poleincluding Complete Electricalconnection By Appropriate Size Of Copper Lugs Complete All As Specified And Directed 88 S&F In Replacementof Mcb Spn 63 Amp 240 Volt CCurve Complete All As Specifed And Directed. 89 S&F In Replacement Of Mcb Sp6 To 32 Amp 240 Volt C Curve 10 Ka Complete All As Specified And Directed. 90 S&F Led Batten 4 Ft Surface / Wall Mounted With Specially Designed Powder Coated Aluminium Housing, High Optically Efficient Polycarbonate Diffuser, In Built Electronic Driver Duly Wired Upto Terminal Block, Power Consumption < 20W ( 4 Ft 20 W ) , Luminaire Lumen >2000 Lm, System Efficiency Of > 120 Lumens / W, With Led Binning As Per Ansi Bin C78.377A, Photo Biological Safety Report As Per Iec624718 & Electrical Insulation Class I, Ingress Protection Ip 20, Colour Rendering Index Cri>80, Temp Range 0 To 45 ºc, Driver Efficency >85%, Power Factor >0.9, Thd <20% As Per Iec 61000-3-2, Colour Temp - 6500K, Surge Protection 2.5 Kv, 50000 Burning Hrs ( Min ) As Per L70 Criteria, Two Stages Isolated Constant Current Operated Driver With Range 150-270V Ac And Safety Extra Low Voltage Safe Level <60V Dc As Per Iec Standard With Lm70 & Lm80 Certification And Connecting The Same In Electric Source With And Using Pvc Sheathed And Insulated 3 Core Copper Conductor Cable Of Size 0.75 Sqmm And Fixing Arrangement For Fixing The Light Fitting Complete All As Specified And Directed. 91 Supply And Fxing Led Batten Tube Light Surface / Wall Mounted With Specially Designed Powder Coated Aluminum Hou Sing, High Optically Efficient Polycarbonate Diffuser, In Built Electronic Driver Duly Wired Upto Terminal Block, Power Consumption <10W ( 2 Ft 10 W ) , Luminaire Lumen >1000 Im, System Efficiency Of >120 Lumens / W, With Led Binning As Per Ansi Bin C78.377A, Photo Biological Safety Report As Per Iec624718 & Electrical Insulation Class I, Ingress Protection Ip 20. Colour Rendering Index Cri>80, Temp Range 0 To 450C, Driver Efficency>85%, Power Factor>0.9, | Thd <20% As Per Iec 61000-3-2, Colour Temp -650Ok, Surge Protection 2.5 Kv, 50000 Burning Hrs ( Mnin ) As Per L70 Criteria, Two Stages Isolated Constant Current Operated Driver With Range 150- 270V Ac And Seafty Extra Low Voltage Safe Level <60V Dc As Per Iec Standard With Lm70 & Lm80 Certification Completed All As Specified And Directed. 92 Supply And Fixing Led Luminaire 600 Mm X 600 Mm, 35 / 36 Watt, 220 V Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete. 93 M&L For Sub Main Wiring With Two Single Core 6 Sqmm Frls Copper Conductor Pvc Insulated And Unsheathed Cableincluding Pvc Conduit Medium Grade ( Appropriate Size ) Concealed In Wall For Sub Main Connection Including 6 Sqmm Frlsinsulated Multistranded Unsheathed Copper Conductor Used As A Earth Wire To Common Earth And Connection To Earth Dolly Complete All As Specified And As Directed. ( Note :-Two Runs Of 6 Sqmm Frls And One Run Of 6 Sqmm Frls Copper Conductor Shall Be Measured As One Unit Length. ) 94 Supply And Laying Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Armoured Service Cable Pole To Building Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 10 Sqmm 4 Core Including Dismantling Complete All As Specified And Directed. 95 M & L For Sand Cushioning For Cables Complete All As Specified And Directed . 96 M & L For Old Size Brick Well Burnt, Laid Flat, For Cable Protection Complete All As Specified And Directed. 97 Excavation In Trenches Not Exceeding 1.5 Mtrs Wide And Not Exceeding 1.5 Mtrs In Depth For Laying Of Cables Including Getting Out In Any Type Of Soil Complete All As Specified And Directed. 98 Returning Filling In Including Spreading, Leveling , And Well Ramming, In Layers Not Exceeding 25 Cm Each Layer Of Any Type Of Soil Complete All As Specified And Directed 99 Removing Surplus Excavated Material From Site Not Exceeding 50 Mtrs From Starting Point And Depositing Where Directed At Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified And Directed 100 S&F Of Metal Plug & Socket Db With Metal Plug And Mcbs Dobule Pole And Neutral Enclosere With A Two Pin Earth Plug And Socket Suitable For 20 Amp Complete With One Single Pole Mcb Complete All As Specified And Directed. 101 S & F Building Security Led Light 20 Watt Made Up Pressure Die-Cast Aluminium Housing With High Power Led As Lighting Source And Lens Embedded Pc Having Top Opening Separate Driver Compartment With Ip-65 Protection And Impact Resistance Of Ik 07 For Building Secuity Purpose With Bracket Size Made Of Gi Pipe Medicum Grade 40 Mm Dia 1.5 Mtr Long Bend To Shape As Required And Fixing With Two Nos Ms Clamp Of Size 40X6 Mm For Fixing Of Builiding Security Light Fittings Completed All As Specified And Directed. 102 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick, Burried Directly Into The Ground ( Earth Pit Not Less Than 2.25 Mtr Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Gi Earth Wire4 Mm Dia By Means Of Bolts, Nuts, Check Nuts, And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No - 3 Connected To Earthing Test Point All As Specified Or Indicated Including Excavation And Connected Earth Work, Pcc Chamber And Cover, Watering Pipe, Funnel Wire Mesh But Without Earth Lead Protection Pipe And Test On Completion After Dismantling Unserviceable Erthing ( Above Gl Only ) Complete All As Directed Incl Dismantling Of Exsisting Earthing. ( Note :-On Testing After Completion If Desired Earth Resistence Is Not Obtained, The Earthing Will Be Redone At No Extra Cost. )