| 1 | Sch \"A\" Part-I B/R work:-Surface dressing n exc 15 cm deep in any type of soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation,and not exceeding 10 sqm on plan for manholes, pier hole, shafts, wells, laying of pipes etc and getting out in any type of soil, complete all as specified. and directed by Engr-in-Charge. |
| 3 | M&L for Cement concrete Type D-2 1:4:8 (using 40 mm graded graded crushed stone aggregate) in foundations, filling and mass-concreteandsub base of floor complete all as specified. and directed by Engr-in-Charge. |
| 4 | M&L for brick work with sub class \"B\" brick, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 5 | M&L for Fly ash brick work, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 6 | M&L for Fly ash brick work, straight or curved on plan to any radius in half brickthick walls built in cement mortar 1:4 complete all as specified and directed. |
| 7 | Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified. |
| 8 | Removal to excavated material (Soil) to a distance not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for hardcore of Broken stone or boulders n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 10 | M&L for 150mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base Finishing surfaces of concrete to be even and rough complete all as specified and as directed. |
| 11 | M&L for 100mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base Finishing surfaces of concrete to be even and rough complete all as specified and as directed. |
| 12 | M&L for 75mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base Finishing surfaces of concrete to be even and rough complete all as specified and as directed. |
| 13 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed. |
| 14 | M&L for Glazed coloured ceramic tiles in vertical surface 450X 350X 7-8mm thick such as skirting dado, etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shed of tile including laid over 10mm thick backing layer of cement mortar (1:4) complete all as specified and as directed |
| 15 | M&L for rendering 20mm thick in CM 1:3 mixed with liquid water proofing compound (as per manufacturer instruction) on fair faces of brick work, stone, concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and as directed. |
| 16 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work, stone, concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and as directed. |
| 17 | M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick work, stone, concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and as directed. |
| 18 | Supply only liquid water proofing compound all as specified and as directed. |
| 19 | M&L for preparation of newly plastered surfaces of wall and applying minimum 2mm thick wall care putty on the surfaces & making the surface absolutely smooth surface and applying two coat of distemper oil emulsion over and including one coat of primer complete all as specified and as directed. |
| 20 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in flooring, PCC path, plinth protection and surface finished even and fair with out using extra cement all as specified and as directed. |
| 21 | S&F modern finished vainity type vitreous china wash basin, table top or table fixed of approved size, flat back, with granite top finished of any colour, pattern or texture with cabinet type boxes or soft sliding drawers as per material and size recommanded by Engg-in-charge, including angle valve, pvc connection, brackets, CP brass waste fitting 32mm dia, PVC waste pipe 750mm long cutting for pinning in ends of brackets or erecting stand complete all as specified and as directed by Engg-in-charge |
| 22 | S&F 600mmx450mm beveled edge mirror of selected quality glass not less than 5.5 mm thick with edges rounded or beveled , mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 23 | S&F 15mm bore dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for basin, sink, bath complete all as specified and directed. |
| 24 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of 110mm bore pipe complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F PVC (SWR) bends of radius 110mm bore complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F cast iron floor trap 110 mm dia with grating, including jointing to waste pipe complete all as specified and as directed |
| 27 | S&F PVC (SWR) 110mm bore vent cowl complete all as specified and directed by Engr-in-Charge. |
| 28 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed. |
| 29 | S&F galvanised iron, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors in any length of 20 mm bore pipe complete all as specified and directed by Engr-in-Charge |
| 30 | All as per Srl item no. 29.00 here-in-before but 15 mm bore |
| 31 | S&F brass CP Soap Dish or Soap Holder Dish round/oval shaped for Bathroom with fixing arrangement complete all as specified and as directed. |
| 32 | S&F brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed. |
| 33 | S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm longfixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 34 | S&F 15mm bore dia fancy type capstan head, chromium plated angular valves /stop valves, cast copper alloy, screwed down, high pressure ,screwed both ends for iron pipe or for unions and fixedcomplete all as specified and directed. |
| 35 | S&F 15 mm dia PVC connection of 600mm long including 2 Nos CP brass check nuts |
| 36 | S&F Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position with all fittings all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) complete all as specified and as directed. |
| 37 | S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipes of 15 mm bore all as specified and as directed. |
| 38 | S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipes of 15 mm bore all as specified and as directed. |
| 39 | S&F factory made Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 40 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified . |
| 41 | S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised |
| 42 | S&F 200mm long aluminium anodised, barrel tower bolts of extruded section |
| 43 | S&F factory made Pressed steel frame of size 125x60x1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete and back filling ofhollow portion of frame includingfixing of hold fast with plain cement concrete type B-0, 1:2:4 using 12.5 mm graded crushed stone aggregate complete all as spd and directed |
| 44 | S&F factory made 350mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, confirming to IS- 2202(Part-I-1999), including prepration of surfaces and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed |
| 45 | S&F steel window/Ventilator factory made box type and shutter (double shutter) with sash bar made out ofsection using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills made out of 10 mm dia round bars glazing with 3 mm thick oridinary glass, guaging (wire mesh stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts ) and two coat synthetic enamel paint over and including a coat of red oxide primer allas per drg No CEPZ/ TD-245/01 Sheet 1/1 and CEPZ/TD-246/01 sheet 1/2 & 2/2 complete all as specified & directed. |
| 46 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 110mm bore pipe complete all as specified and directed by Engr-in-Charge. |
| 47 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 49 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws as specified |
| 50 | M&L for structural mild steel work as angles/rectangular hollow section/steel tubular roof trusses (framed), purlines and fastening including distance pieces etc. using EWR or induction butt welded tubes conforming toIS-1176-1779 gde st-240 complete all as specified and directed. |
| 51 | S&F Framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; railings; framework of water tanks ,framed and hung as in steel gates including pintle hinges, stops,hand-made sliding bolts etc and similar work conforming to Fe.290.Gde-E-165,ornamental and intricate design complete all as spd and directed. |
| 52 | M&L for preparation of newly steel and ironsurfaceof any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over a coat of red oxideprimercomplete all as specified and directed. |
| 53 | M&L for preparation of newly wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat ofpink primer complete all as specified and directed. |
| 54 | S&F one piece EWC with soft closing seat cover and fittings complete, 710 x 370 x 745 mm, modern curvy design with flushing efficiency 3.90/2.10 LPF complete, the shade of EWC to be approved by Engr in Charge, complete all as specified and directed by Engr-in-Charge. |
| 55 | S&F forsuspended false ceiling system using chicago metallic (E grid) exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600 mm length) Cross Tee of dimensions 29mm X24mmX 0.8mm thick and wall angle 22.2mmX22.2mmX0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed, self embossed. textured designer board, water resistant termite resistant, fire resistant for insulation to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) complete all as specified and directed. |
| 56 | Taking down old any type description of Heritage ,Texture finished surface including preparation of surface and M & L for applying heritage/Texture finish surface such as fine flakes features/heritage flakes textures features/heritage granite finish/ heritage granules finish/ heritage surface textures/metallic/stone finishes/natural finishes/super matt paint finish/fine flakes /fine granules etc complete application process as per manufacturer’s recommendations in any tint design & pattern as approved by GE including bonding agent & top coat including trowelled on the surface on internal or external surfaces including matching with existing work including necessary scaffolding any height height as required at site complete all as specified and as directed. Note: All painted areas site to be cleaned and hand over as earlier without any extra cost to Govt |
| 57 | S&F mild steel TMT bars 10 mm dia and over,cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge. |
| 58 | M&L for UPVC drain pipe 200mm dia type \"B\" with wall thickness 4mm of pressure rating 8KN/Sqcm laid in tranches and jointed with cement solvent including testing complete all as specified and directed by Engr-in-Charge. |
| 59 | M&Lfor concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 150 mm bore pipe, complete all as specified and directed by Engr-in-Charge. |
| 60 | Precast reinforced cement concrete, type B-1,1:2:4(using 20mm graded crushed stone aggreagate)as inin landings, manhole cover set in cement mortor 1:6 , including neccessory form work complete all as specified and directed by Engr-in-Charge. (Note:-TMT bars will be masured and paid sepretly) |
| 61 | M&L for cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 62 | M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match complete al as specified and directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles and brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed |
| 63 | M&L for Cement Concrete , 1:2:4, type B-1 using20mm graded crushed stone aggregate as in lintel upto 1.50 m span, cills, steps, seismic and other silmilar bands, plinth courses, sring courses,lacing courses, parapets and railings upt 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, bands, mud stopwater troghs and the like including weathering, slightly rounded or camphered angles and throating, complete all as specified and directed by Engr-in-Charge. |
| 64 | M&L for 80mm thick M-40 Grade, coloured rubber moulded glossy finish Machine pressed precast concrete interlocking paver block confirming to IS 15658-2006 with grey cement and pigment including 45mm thick sand cushioning bed complete all as secified and directed.Note:-Shape, size and colour of interlocking paver block and laying pattern shall be approved by GE. |
| 65 | Sch \"A\" Part-II E/M work:-M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable withand including PVC concealed conduit heavy duty 20 mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked for switches and sockets , including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 66 | All as per Srl item No 65 here-in-before but for 5 pin 5 amps socket outlet on independent board complete all as specified and directed. |
| 67 | M&L for point wiring with 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface tomatch with the existingsurface complete all as specified and directed. |
| 68 | S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 69 | S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. |
| 70 | S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. |
| 71 | S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 72 | S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specifiedand directed. |
| 73 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 74 | S&F LEDbulb, B22type ,14 watt,complete all as specified and directed. |
| 75 | S&F sleek LED Battenlight fitting 4 feet long 1x22 W including LED tube 4 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed. |
| 76 | S&F energy saving, surface mounted LED Bulkhead fitting 10 watt with PDC aluminium housing and polycarbonate diffuser with IP-66 protection all as specified and directed by Engr-in-charge. |
| 77 | M&L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller PVCAC ventilating fans, Engineering plastic with louvers shutter,Single phase, 230 volts 250 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 78 | S&F sheet metal enclosure, distribution boarddouble door made out of(CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral link, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface including making good the disturbed surface as per existing complete all as specified and directed |
| 79 | S&F MCB SP 6-40 Amp 240 volt AC with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 80 | S&F MCB SPN 6-40 Amp 240 volt AC with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 81 | M&L for sub Main Wiring with two Run of single core PVC insulated unsheathed multistrand FRLS flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm(green colour)as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete andmaking good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed.Note:-Two run of submain wire (phase and neutral) and one run of earth wire including PVC conduit and accessories will be measured as one run. |
| 82 | Supply and installation of the electric water storage heater of ABS body type, 25 ltr capacity with rated power 2KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/nuts on both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangements and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as directed. |
| 83 | M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)withtop edge of the platenot less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precastPCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth workin any type of soil , removal of surplus soil to a distancen.exc 50m and connecting , testing on completion completeall as shown on electricplate No 03 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted). |