Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-11-2023 | addendum 2 | Date | 21-11-2023 |
| 2 | 16-10-2023 | addendum 1 | Technical Bid | 07-11-2023 |
| Sl. No. | Item Description |
| 1 | Part A Civil Work |
| 2 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 6 | Providing and laying damp-proof course with cement concrete grade M-15 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .50mm thick. Sqm |
| 7 | Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : cement mortar 1:4 (1 cement : 4 coarse sand) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix). |
| 9 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :. Suspended floors, roofs, landings, balconies and access platform. |
| 10 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :. Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :.Weather shade, Chajjas, corbels etc., including edges. |
| 12 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 13 | Random rubble dry stone Kharanja (soling) under floor. |
| 14 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75mm deep chase |
| 15 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). |
| 16 | Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : Area of each slab 2001 to 5000 sqcm. |
| 17 | 40 mm thick rubbed stone flooring over 20 mm (average) thick baseof cement mortar 1:5 (1 cement :5 coarse sand) with joints 3mmthick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust)admixed with pigment to match the shade of stone and pointing withsame mortar Red sand stone |
| 18 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thicknessWith float glass panes of 4.0 mm thickness |
| 19 | Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) :. Red sand stone - Exposed face machine cut and table rubbed with rough backing. 40 mm thick |
| 20 | Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) :. White sand stone - Exposed face machine cut and table rubbed with rough backing.. 40 mm thick |
| 21 | Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :1:4 (1 cement : 4 fine/ coarse sand) |
| 22 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) |
| 23 | Supplying and fixing machine cut fine dressed Red/Pink sand stone dasa or coping, with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 75 mm thick |
| 24 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete |
| 25 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied @ 1.25 ltr/10 sqm. over and includingone coat of Special primer applied @ 0.75 ltr / 10 sqm. |
| 26 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
| 27 | Providing non slip grooves to granite/ kota, stone flooring, counters, vanities etc. using groove cutter V type machine etc. complete as per design approved by engineer in charge |
| 28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 29 | Removing of old lime plaster up to 75 mm thick in patches with height up to 4.5 m. Disposal up to 100 meter lead |
| 30 | Dismantling old plaster or skirting raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumpingground within 50 metres lead. |
| 31 | Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10 m height with 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately)Exposed face Machine cut |
| 32 | P & L Lime Surkhi Plaster lime surkhi mortar 1:2 (1 Lime : 2 Surkhi)including preparation of mortar by traditional practice (by grinding) inspecified course for base coarse and subsequent course & Loi, tamping, beating, curing till the shrinkage cracks are disappear. The work is to be done with all lead as the work is of restoration nature as per Jaipur practice including adding gur, methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 days of previous coat. 45 mm thick in four coats |
| 33 | P & L Lime Sand Plaster with lime sand mortar 1:2 (1 Lime : 2 Sand)including preparation of mortar by traditional practice (by grinding) inspecified course for base coarse and subsequent course & Loi,tamping, beating, till the shrinkage cracks are disappear. The work is done with all leads as the work is of restoration nature as per Jaipur practice including adding gur, methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 days of previous coat.25 mm thick in three coats |
| 34 | Add extra over item no. 40.5 to 40.6 for Lime plaster work done overSpherical or groin ceiling/ladao ceiling of doms. |
| 35 | Add extra over item no. 40.5 to 40.6 for Lime plaster work done overflat ceiling. |
| 36 | Providing & applying Lime kara 1:2 (1lime cream : 2 Zikki powder)grinding mortar with grinding mill/manually on lime base, on ceilingand all flat surface in two coats. First coat applying 3 mm to 4 mm thick and curing properly at least 7 days, second finishing coat done after 7 days of previous coat as per traditional practice.(thickness not more than 6 mm.) |
| 37 | Add extra for Lime Kara work (on lime plaster base) other than flatsurface as per traditional practice with all lead & lift with fine finishingcomplete in all respect on : Domical surface/spherical/domical ceiling |
| 38 | Add extra for Lime Kara work (on lime plaster base) other than flatsurface as per traditional practice with all lead & lift with fine finishingcomplete in all respect on : Curved surface. |
| 39 | Tuman masonry by brick bats/ stones in grinded mortar of LimeSurkhi mortar 1:2/lime sand mortar 1:2 including racking andremoval of all old loose plaster and cleaning the wall surfaceproperly as per direction of Engineer In-charge. |
| 40 | Scraping & Removing of white wash/ distemper/algli etc. from plainplaster & surfaces gently with care to keep intact the old designs. |
| 41 | Scraping & Removing of white wash/ distemper/oil paint /algli etc.from lime plaster highly decorative, ornamental and stucco work withat most care by using fine sand paper under the close supervision tokeep intact the old designs. |
| 42 | Providing and applying breathable, non-reactive, transparent,antifungal, UV resistant, alkaline stable, impregnable silane-siloxaneor equivalent based water repellent coating on exposed absorbingsubstrate like stone surface/ concrete surface/ mineral paintedsurface / exposed brick surface / lime surface in two or more coatsto give uniform finish surface in all heights, horizontal, inclined,vertical and on ceiling complete in all respect and making it completewater-proof as per direction of the Engineer-in charge. |
| 43 | De-vegetation from monument by removing bushes, trees includingcomplete uprooting from the wall & roofs structures carefullyincluding suitable chemical treatment to roots to avoid further growthincluding disposal of rubbish with in 50 mtr. Lead as per direction ofEngineer in-charge. |
| 44 | Providing and applying ceilent adhesive to existing cracks by suitable silicon or equivalent ceilent complete in all respect and making it complete water-proof as per direction of the Engineer-in charge. |
| 45 | Flush and ruled pointing over joints of dressed stone cladding, cchajjas, jali etc. including racking the joints as per traditional cpractice including all leads and lifts with grinded mortar of lime puttyand surkhi mixed in 1:2 ratio and gur, methi, gugal etc. are to be mixed as per traditional practice. |
| 46 | Water proofing with consolidation of basic substrata, making itcomplete water proof with Protekta series of compounds orequivalent as per manufacturers specifications and as per direction of engineer in charge |
| 47 | Removal/Clean Ornamental Stone with Diamond/Surgical tool Kits ofthe original surface of stone carving & traditinol Mewar work ofBiradari including Todies ,lamcha ,etc by careful removal of uppercoating of lime Khara /whitewash/paint/distemper/plaster, araish etc. without any harm to the original hidden art work, conservation of thetraditinol & strengthen the original art work with the preservativecoating and making it water proof as per direction of the Conservation. |
| 48 | Removal , providing and re fixing of stone dasa moulded as perexisting design with fine finishing fixing in grinded lime mortar 1:2 i/call lead and lift complete in all respect. extra for carving (pan patti)- 100mm thick |
| 49 | Khamira Colour Washing as per old traditional practice to prepare the Khamira the lime should be slaked at least for 7-10 days and regularly it should be stirred by adding cured, Gugal, for nonsynthetic colour adding gum (babool gum) as per specification. Then applying prepared solution on walls three to four thin coats as desired finishing. |
| 50 | Stucco work in lime, Surkhi, mortar (1:2) as per existing design work/ traditional practices by skilled craftsman, the stucco work should be done as per restoration nature, the mortar should be prepared by grinding mill adding gur, methi & gugal.. The thickness varies from 50 mm to 100mm as per the design (minimum rectangular surface area to be measured). |
| 51 | Making Mehrab\"s, Arches, pillars, highly decorative creepers, flowerof small sizes etc.in lime Surkhi plaster (1:2) as per B248oldtraditional practices (Arches, Mehrab\"s) in three coats for basecourse and subsequent course and Loi tamping, beating till the shrinkage cracks are disappear than making ornamental flowering/design etc. The work is to done with all leads and lifts asper work of restoration nature as per Jaipur practice. |
| 52 | Chemical treatment of sand stone to clean from yellowness,blackness, algal growth, dust, dirt oily accretions, lime & gypsumdeposits, filling of cracks/ joining of gaps/ pointing, strengthening ofweak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof. |
| 53 | Chemical treatment of marble stone to clean from yellowness,blackness, algal growth, dust, dirt oily accretions, lime & gypsumdeposits, filling of cracks/ joining of gaps/ pointing, strengthening ofweak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof. |
| 54 | Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metres lead. For thickness of tiles above 25 mm and upto 40 mm |
| 55 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 56 | Providing and fixing fine dressed \" marble stone flooring \" with whitelime stone (raj nagar stone) machine cut of approved shade set inpattern over 20mm thick base of cement mortar 1:3 including jointingfinished flush with white cement and stone powder with an admixtureof pigment as per direction of Engineer incharge. (50 75mm thick) |
| 57 | Providing and fixing 1st quality MAT finished ceramic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 58 | Providing and fixing 1st quality MAT & GLOSSY finished ceramictiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with waterabsorption less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4) Size 300mm x 600mm |
| 59 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Jhunjhunu / Jalore (Red / Choclate Colour)Above 3601 Cm2 Slabs |
| 60 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-incharge. In cement mortar |
| 61 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal designcomplete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. |
| 62 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 64 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 65 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore. |
| 66 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore. |
| 67 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore |
| 68 | Providing and fixing PTMT grating of approved quality and colour.Circular type.125 mm nominal dia with 25 mm waste hole. |
| 69 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank per |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc., 20 mm nominal outer dia .Pipe |
| 71 | 25 mm nominal outer dia .Pipes. |
| 72 | Providing and fixing square-mouth S.W. gully trap grade \"A\"’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : With bricks class designation 75 |
| 73 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe. |
| 74 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design :With bricks. |
| 75 | Providing and fixing on wall face Unplasticised Rigid PVC Single socketed pipes rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 75 mm diameter |
| 76 | Providing and fixing on wall face Unplasticised Rigid PVC Single socketed pipes rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm diameter |
| 77 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 75 mm |
| 78 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm |
| 79 | Bend 87.5° 75 mm bend |
| 80 | Bend 87.5° 110 mm bend |
| 81 | Providing and fixing Unplasticised P.V.C. connection pipe withPTMT Nuts collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length. |
| 82 | Grading roof for water proofing treatment withwater proffing compound . Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 83 | NSR Items CivilWorks |
| 84 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywith property of being termite/borer proof,water/moisture proof andfire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Frame size 65 x 150 mm |
| 85 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick |
| 86 | Providing and fixing Stone jali 50mm thick Beige sand stone as per ornamental design to fixed with white cement/epoxy mortar including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, complete in all respect as per engineer in charge |
| 87 | Supplying and fixing beige sand stone rain water spouts fine (3 lines) dressed as per approved design of size : Beige sand stone 60x26x18 cm |
| 88 | Providing and fixing View Similar Products Silver SS Cloth Wall Hanger, Door, Size: 12 Inch Color Silver Material SS, Size 12 Inch Usage/Application Cloth Hanger, Shape Rectangular, No Of Hook 6 complete in all respect as per direction of Engineer Incharge. |
| 89 | Providing and fixing \"Tactile\" anti skid surface sand stone/ approved stone flooring for Floor/ Steps with fine dressed with deep round Grove As per drawing and as per approved design and size over a base cc and in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade,, complete in all respect, Tactile pattern/design and drawing as per direction of Engineer Incharge.upto 50 mm. thick stone slab |
| 90 | Stone Signage at changing room and ramp : Providing and fixing of 40-50mm thick (Size-H-0.600 mtr, W-0.600 mtr) Dholpur Red sand stone, design and shape as given in drawing, stone finish shall be in sand blast, text on stone shall be engraved as per engineer in charge along with both fonts of hindi and english and painted, fixing shall be done on wall including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade as specified complete in all respect as per direction of engineer incharge.The design shall be approved by the authority. All work shall be done as per specifications and satisfaction of authority including all transportation, loading, unloading and fixing. |
| 91 | Building Signage : Providing and fixing of 40-50mm thick (Size- H-0.75 mtr, W-0.75 mtr) of Dholpur Red sand stone, design and shape as given in drawing, stone finish shall be in sand blast, text on stone engraved as per engineer in charge along with both fonts of hindi and english and painted, fixing to be done on wall at certain height at Ghat entrances including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade complete in all respect as per direction of engineer incharge.The design shall be approved by the authority. All work shall be done as per specifications and satisfaction of authority including all transportation, loading, unloading and fixing. |
| 92 | Building signage: Providing and fixing of 40-50mm thick (Size-H-0.750 mtr, W-0.750 mtr)in Makrana or equivalent white marble, Design and shape as given in drawing, polish as specified by conservation architect, text on stone engraved as per engineer in charge along with both fonts of hindi/english engraved and painted, fixing to be done on wall at certain height at Ghat entrances including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade complete in all respect as per direction of engineer incharge. The design shall be approved by the authority. All work shall be done as per specifications and satisfaction of authority including all transportation, loading, unloading and fixing. |
| 93 | Providing & Fixing of Beige sandstone Round Bollard in sand blast finish (with provison of chain to be hooked) Size 0.20M X.20M X1.2M (Top d(small diameter)=upto 200mm with vertical H. above ground =900mm Post and D (bigger diameter)=300mm) to be fixed on base stone of 375x250mm, joinery to be carried out in dowel as specified by conservation architect, complete bollard to be fixed beaneath the ground as per drawing given in dpr. Pit size shall be 710x710x500 to be filled with PCC 1:3:6 at base and side filling in brick. Bollards to serve as barricades at entrances of specified numbers and positions as per design and approval of architect complete in all respect as per direction of Engineer Incharge. |
| 94 | Providing and fixing Dholpur Beige Sand stone Jali in sand-blast finish, Size Length 1200mm Width 750mm Thick 60mm Solid stone Jali, 3D laser cut shall be carried out on both side of stone, design and shapes as specified by conservation architect, stone shall be selected and sorted from uniform color Without cracks Chipping, desing , shape and carving as provided in DPR including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade complete in all respect as per direction of Engineer Incharge. |
| 95 | Providing and fixing Dholpur Beige Sand stone Jali Post in sand-blast finish, Size Length 150mm Width 150mm Height 1100mm Solid stone Jali Post, design and shapes as per Drawing, stone shall be selected and sorted from uniform color without cracks , Chipping, desing , shape and carving as provided in DPR including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, post to be fixed on base stone of size 250x250x250mm and pit size shall be upto 710x710x500 complete in all respect as per direction of Engineer Incharge. |
| 96 | SITC of Mobile toilet Size (1MTRx1MTRx2.4MTR) 3+3(Six) seated Indiantoilet With Stainless Steel European Ewc ,washbasin Door Shall be 6’ x 2.3’ approx., Wastage Tank 500Ltr(1MTRx1MTRx0.6MTR)complete in all respect as per direction of Engineer Incharge. |
| 97 | Stone bench : Providing & fixing Dholpur red sand stone bench in leather finish for Bench of size 2.0 m X 0.55 m X 0.75 m as per drawing & design with a back and side arm rests. All joinery/ joineries including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade as specified by conservation architect and as approved by engineer incharge, all work shall be done as per specifications and satisfaction of authority inclusive of all transportation, loading, unloading and fixing complete in all respect. |
| 98 | Dustbin : Supplying &fixing fine dressed \"STONE-STEEL Composite DUSTBIN\" made in dholpur red sand stone as base (1005x500mm) and side supports (1200x708) as shown in design in DPR, stone finish shall be sand blasted finish including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade. Steel pipe 100x25mm shall be fixed with nuts bolts and plates in center of base. To side stone support and iron pipe, two Steel Buckets as Dry and Wet garbage respectively shall be pivoted so as to make it rotatable to clean, with size of steel bucket dustbin as 0.50X0.50X1.0 mtr. with chamfer moulding on stone edges and steel color as specified by engineer incharge including all hardware and tools required to finish the job, complete work as per approved by Engineer incharge, complete in all respect. |
| 99 | Signage map : Providing and fixing Dholpur beige sand stone post of size 2000x800x200mm with base of size upto 1200x800 and depth as required to fix at floor at various ghats listed in DPR, finish of stone shall be in leather finish including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade. A U-shape groove 12x12mm shall be created on 200mm side\"s stone facia. Above the stone surface High Intensity retro reflective Type XI sign plate to be fixed, size upto (1.7mtrX1.7mtr) made out of 2.00 mm thick aluminium sheet face to be fully covered with brown high intensity grade retro reflective sheet with logo, lettering, border made with white similar sheet after etching, the black side is to be painted with epoxy grey paint. The sheet is to be fixed on frame of iron/aluminium with help of iron/aluminium rivets. The sheet shall be folded at sides neatly to cover the gap created between stone and sheet because of frame, frame should not be visible from sides. Stone joinery and foundation shall be as per specified by conservation architect. The shape of signage map shall be as per design and specification specified in DPR by architect and Engineer incharge. The design shall be approved by the authority including all transportation, loading, unloading and fixing complete in all respect in supervision of engineer incharge. |
| 100 | Providing and fixing in position Stone Kerb made of Dholpur Stone of size 150 mm x 350 mm (length 1150 to 1200 mm, or it may varies as per site requirement at curves, junctions, ends, etc as per direction of EIC) and cut to shape viz. 50mm chemphering at top and 100mm at side complete in all respect as per design, with exposed face fine machine dressed fixing and jointing/ pointing with cement mortar 1:3 using pigment to match the shade of stone, also include cutting of road bituminous base, WMM, GSB, earth, etc in complete width for laying/ fixing stone kerb in true line & levels including disposal of surplus unseviceable material with all lead & lift complete in all respect as per drawing and instruction of Engineer Incharge. |
| 101 | Providing and fixing \"Corrugated\" surface sand stone/ approved stone flooring for ramp-way with fine dressed corrugation work as per approved design and size over a base cc and in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade,, complete in all respect, as per direction of Engineer Incharge.75 mm. thick stone slab |
| 102 | COMPONENT - B ELECTRICAL WORK |
| 103 | Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 450 mm sweep(900/1400 RPM) |
| 104 | Providing & Fixing of ISO Certified company made BEE Approved copper wounded 1200 mm sweep BLDC technology power saving ceiling fan with longer life span and low maintenance 5 star rated which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 215 CMM, speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod up to 30 cm with secondary support safety cable , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 105 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy =100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR. |
| 106 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 107 | SITC of chemical Gel earthing system of Dual Pipe Technology made of with \"B\" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043- 1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter inmeasurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell, GI pipe 3000 mm long, 80 / 50 mm, Terminal 50 mm x 6 mm GI Strip |
| 108 | Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,Jointing shall be done by overlapping and with 2 set of Brass (for Custrip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . 25mm x 3mm G.I. ( Hot Dipped ) Strip |
| 109 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .2 x 1.5 sq.mm |
| 110 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 111 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 112 | Supplying and drawing FR PVC insulated & unsheathed flexiblecopper conductor as per PWD specification for electrical Works withISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wireshould be made from 99.99% purity copper, class 5 stranding inacc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) forless chances of oxidization and higher silver content for gives betterconductivity , insulation PVC type A or C ,flame retardant as per IS10810-53, better amperage rating as per VDE 0298 part 4, , inexisting surface or recessed PVC/ MS conduit/casing cappingincluding all as per pre approved by Engineer in charge,makingconnections, etc. as required. OEM Must have its own in houseNABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \"A\"attached with this BSR . 2 x 2.5 sq.mm |
| 113 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III )vergin material PVC conduit as per PWD specification for electricalWorks along with its accessories (IS: 3419 ) as required in recessincluding cutting the wall, covering conduit and making good thesame as required. All relative and latest acceptance tests reports byany NABL accredited lab for the conduit shall be submitted beforeexecution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . E010410 MMS ( IS:9537 P - III ) PVC conduit |
| 114 | P &L of lP66 protected high power high power LED linear flood lightsystem. Fixture made of powder coated extruded aluminium housingwith UV stabilized PC/toughened glass cover and appropriate lens to be used to achieve various beam angle pattern. fixture suitable forinput 12vDC, power consumption should be 6W/0.5A per feet withsystem CRI- 70, color red/ green / blue/ /RGB /W/WW. the fixturemust have IP66 protected 5mm Round female connector for input,the fixture must have provision to extend further . system life of50000burning hours with 70% of initial lumens maintained . lightoutput in red, green, blue, cool, white or warm white colour as perrequirement. fixtures shall be CE complete series of linear floodlight. linear LED strip 1 feet (with driver) |
| 115 | P &L of lP66 protected high power high power LED linear flood light system. Fixture made of powder coated extruded aluminium housingwith UV stabilized PC/toughened glass cover and appropriate lens to be used to achieve various beam angle pattern. fixture suitable forinput 12vDC, power consumption should be 6W/0.5A per feet withsystem CRI- 70, color red/ green / blue/ /RGB /W/WW. the fixturemust have IP66 protected 5mm Round female connector for input,the fixture must have provision to extend further . system life of 50000burning hours with 70% of initial lumens maintained . lightoutput in red, green, blue, cool, white or warm white colour as perrequirement. fixtures shall be CE complete series of linear floodlight. Linear LED Strip 2 Feet (with Driver) |
| 116 | P&I of IP66 protected High Power LED Linear FloodLight System. Fixture made of powder coated ExtrudedAluminium Housing with UV stabalized PC/ToughenedGlass cover and appropriate lens to be used to achievevaious beam angle pattern. Fixture suitable for input12V DC, Power consumption should be 6W/0.5A perFeet with System level Luminous efficacy >80Lumen/W. LM80 Approved RGB LEDs to be used.System CRI>70, Color Red/ Green/ Blue/ RGB/ W/ WW.The fixture must have IP66 protected 5mm Roundfemale connector for input, The fixture must haveprovision to extend further. System life of 50000 burninghours with 70% of Initial Lumens maintained. Lightoutput in Red, Green, Blue, Cool white or Warm WhiteColour as per requirement. Fixtures shall be CEcomplianceSMPS based electronic driver current rating should bechoosen saparately on complete series of linear floodlight. Linear LED Strip 3 Feet (with Driver) |
| 117 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWDspecification for electrical Works in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc.including making necessary connection, testing etc. as required ofsize and as per points (a), (b), (c), mentioned below:-(a) Copper conductor of electrlytic grade copper, purity >99.97 %ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964,IS 3975-1999 for armouring of cables in armoured cable items , IS5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures(c) OEM Must have ISO 9001 & 14001 certifications & its own inhouse NABL lab setup for all testing facilities for cables .Appropriate type test certificate / OEM test report shall be submittedAll above as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 3 corex 2.5 Sq. mm |
| 118 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWDspecification for electrical Works in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required ofsize and as per points (a), (b), (c), mentioned below:-(a) Copper conductor of electrlytic grade copper, purity >99.97 %ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964,IS 3975-1999 for armouring of cables in armoured cable items , IS5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures(c) OEM Must have ISO 9001 & 14001 certifications & its own inhouse NABL lab setup for all testing facilities for cables .Appropriate type test certificate / OEM test report shall be submittedAll above as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 4 corex 6 Sq. mm |
| 119 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWDspecification for electrical Works in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc.including making necessary connection, testing etc. as required ofsize and as per points (a), (b), (c), mentioned below:-(a) Copper conductor of electrlytic grade copper, purity >99.97 %ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964,IS 3975-1999 for armouring of cables in armoured cable items , IS5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications & its own inhouse NABL lab setup for all testing facilities for cables .Appropriate type test certificate / OEM test report shall be submittedAll above as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 120 | 4 corex 16 Sq. mm |
| 121 | 4 core 25 Sq.mm. |
| 122 | Providing & laying of Double wall corrugated pipe confirming to IS :14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below theground for laying cable including making the trench and back filling ,compaction of earth as required( Excavation of Earth to be paidExtra as required. ) of following Outer Dia. / Inner dia as perIS:4984:1995. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 110 / 95 mm |
| 123 | SITC of wall/ free standing floor mounted dust and vermin proofcompartmentalised cubical panel as per PWD specification forelectrical Works, made out of CRCA sheet . Other parametersrequired as per point (a) ,(b), (c), (d) below:-(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mmlength / width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheetsupported by base M.S. channel if required . Side walls and cablealley compartments having bolted type doors with / withoutdetachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process withdephosphating and with powder coating of minimum 70 microns onboth side of panel in desired shade The panel having PU/ Neoprenerubber gasket of not less than 3mm thickness ,required hardware,separate detachable gland plate M.S. base channel (min75mm) ,hinged door with locking arrangement for equipment/switchgear.(c) Interconnection between bus bar and switchgears /cable shall berigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints /interconnections of copper bus bar shall be dully tinned . Clearancebetween main bus bar and risers / metal parts shall be at least 10mm additional to width of bus bar Bus bar is insulated by HeatShrinkable sleeves . Earth and Neutral bus bar shall be half of thesize of phase bus bar.(d) only outer area on all sides shall be measured & panel to befabricated only from CPRI approved fabricator. All as per drawingpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with this BSR |
| 124 | Providing and fixing of IP 65 protected Polycarbonate / Polysterenefuse box moulded with inside knock outs of following size withhinged cover, transparent window, PU gasket, locking arrangement,duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nutand bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 /16.0 sq.mm heavy duty connector, earth terminal, complete in allrespect. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure A\" attached with this BSR . 225 mm X 225 mm X 100 mm |
| 125 | Supply, Fixing and testing of following capacity wall mountedstablisers having output voltage variation from 200V to 250V(+/-5%)with input voltage variation from 170V to 260V, time delay facilityfrom 2 to 4 minute and high cutoff at 270V complete in all respect5 kVA |
| 126 | Providing & Fixing of ISO certified company made IK10IP65 protected Top/Bottom mounted LED Post top Light system. Fixture made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy =90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N)and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintainedLight output in Cool white or Warm White Colour as per engineers choice. driver current <1000mA shown in LM79 report.Fixture must be in compliance with BIS Standards and T.C . Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 127 | 30 W LED Post Top Fixture |
| 128 | Supply & laying of 0.9 mm Teflon copper wire (Fire And WaterResistant) with sleeves ,taping including Grove cutting ,Zirri cuttingin plaster stone wall ,column, roof with Scaffolding , filling chemicalepoxy Araldite ,pvc clips, finished with lime mortar etc. |
| 129 | SITC of Single Disc Scrubbing Machine, 17 inch, 1100 Watt Dimension 540X440X360mm Brush Speed 155 RPM complete in all respect as directed by Engineer-in-Charge. |
| 130 | VAK make decorative haritage pole in 4 Meter height. Pole upper section of length 3mtr is of dia 76mm and 1 meter bottom section of dia 114mm with decorative casting with base plate as per drawing. Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation with cover.Complete in all aspects with foundation bolts |
| 131 | Supply,installation, testing and commissioning of the thermoplastictotally insulated & enclosed floor/wall mounting cubicle type Feeder Piller /Distribuation Boards/Junction Boxes(IP 65) with following properites :-UV /Fire/Acid-Chemical Resistant and Dust/Water/Weather/Shock Proof (IP65), incoming cable entry from bottom of panel& outgoing cables entry from bottom/left/rightsides of panel as per detail design and cable entry and outgoing are only with suitable sizes of screw lessglands ,including with all accessories copperbus bar, din rails, earth links, neutral links, glands, locks, connectors ,etc.Complete with all respects Incomer-32A 4poleMCB-1Nos.,Dinmounted Astronomical 1channel Timer Qty - 1Nos. High/low voltage cutoff Relay, Neutral Faluire protection Relay,- 1Nos.32A 4pole Contactor Switch-1Nos. Surge Protection Device Type-2 - 1Nos.32A. bypass switch-1Nos.,RYB led indicators, 3phase -1 Nos.Volts/amp digital meters - 1 Nos.Outgoing : 16A single pole MCB -2nos. Outgoing : 10A single pole MCB -1Nos. Outgoing : 6A single pole MCB -9nos. Dinmounted Astronomical 1 channel TimerQty - 1Nos.Dinmounted Astronomical 2 channel TimerQty - 1Nos.16A single pole Contactor Switch-2nos. 10A single pole Contactor Switch-1Nos. 6A single pole Contactor Switch-9nos. |
| 132 | Provision of Provisional Sum to be used as tender document (fixed) : INR 10,00,000 . Bidder should fill amount INR 10,00,000. |
| 133 | Water Quality Analysis– Collecting representative sample and Physical & Chemical testing of Parameter from NABL approved laboratory as per CPHEEO manual: PH, TDS, Electrical Conductivity (EC), Taste & Odour, turbidity, magnesium, Total hardness, total alkalinity, chloride, Dissolved Oxygen (DO), sulphate, nitrate, fluoride, Calcium, Iron, Pesticide, Manganese, Cooper, Aluminium, Residual Chlorine, Zinc, phenolic compound, Arsenic, Cadmium, Chromium, cyanides, lead, selenium, Mercury. |
| 134 | Ambient Air Quality Monitoring- For parameters – PM-2.5 & PM-10, SO2, NO2, CO from NABL approved laboratory and submission of report complete in all respect |
| 135 | Ambient Noise Quality Monitoring - To Identify sources of noise, Noise due to traffic/transportation of vehicles, Noise due to heavy equipment operations, Duration and variations in noise over time etc. the equivalent noise levels shall be monitored (Lday and Lnight in Leq dBA) from NABL approved laboratory and submission of report complete in all respect. |
| 136 | Cost of establishment of office accomodation of 300 sq. ft. as per contract clause no. 6.28 including power, telephone and water charges, Rate shall be quoted on monthly basis ( maximum 12 months) andcost of Office operations |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy