| 1 | Dismantling asbestos cement (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and directed. |
| 2 | Dismantling timber scantling 40 Sqcm and over in section, in any position of framed work complete all as specified and directed. |
| 3 | All as per item No. 02 here-in-before but as in unframed work complete all as specified and directed. |
| 4 | S&F in repairs solid PVC wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed. |
| 5 | S&F in repairs 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and directed. |
| 6 | S&F rolled mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. using Fe 410-W(Gde E-250 Quality- A) complete all as specified and directed. |
| 7 | S&Fgusset plates, cleats etc including necessary welding/ fabrications using Fe 410-W (Gde E-250 Quality-A) complete all as specified and directed. |
| 8 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick ofcolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or \"J\" / \"L\"hooks complete all as specified and directed. |
| 9 | All as per item No. 08 here-in-before but plain sheet as in ridges, gutters, facia bd etc complete all as specified and directed. |
| 10 | S&F 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roofs fixed with L-type or J-type or cranked hook bolts complete all as specified and directed. |
| 11 | All as per item No. 10 here-in-before but fixing only complete all as specified and directed. |
| 12 | M&L for asbestos cement two piece adjustable serrated ridge for corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts complete all as specified and directed. |
| 13 | S & F for suspended false ceiling using anodised GI exposed ceiling suspension system of grid size 60 cm x 60 cm width main runner \" T \" section of size 38 mm x 24 mm x 0.4 mm thickness and wall angle of size 24 mm x 24 mm x 0.3 mm thickness and cross Tee of size 24 mm x 24 mm x 0.43 mm thick GI system duly suspended with 4 mm dia Gl bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing position for light fixtures , air conditioning diffuser and ducks , sprinkler , smoke detector etc. The main runner to be secured to structural soffit by hanger @ 1220 mm maximum C/C. The last hanger at the end of each runner should not be placed at more than 450 mm from the adjacent wall . Flush fitting 1200 mm cross \" T \" to be inter locked between main runner @ 610 mm C / C so as to form 600 mm x 600 mm grid including taking down of old existing ceilings complete all as specified & directed. |
| 14 | S&F 4 mm thick non asbestos cement building boards (E boards) to framework with screws in false ceiling one face printed engraving to match existing and factory coted (white) complete all as specified & directed. |
| 15 | S&F IInd class hardwood in scantling timber unframed work and fixed wrought in any position and in any situation complete all as specified and as directed. |
| 16 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed. |
| 17 | M&L for 4 mm thick asbestos cement plain building boards, fixed to timber frame work as in ceilings complete all as specified and directed. |
| 18 | M&L for plain fillets, second class hard wood square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area exc 13 Sqcm and n exc 25 Sqcm complete all as specified and directed. |
| 19 | M&L for three coats of white wash on new surfaces of ceiling boards including preparing of surfaces complete all as specified and directed. |
| 20 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 21 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed. |
| 22 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed. |
| 23 | Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed. |
| 24 | M&L for GI wire netting 0.90 mm dia and 12 mm mesh for lathing to wood or metal studding and welded with angle iron frame including all laps, cutting and waste complete all as specified and directed. |
| 25 | M&L for rendering 15 mm thick on one side of lathing or over brick surfaces finished fair & even in CM (1:4) complete all as specified and as directed. |
| 26 | All as per item No. 25 here-in-before but for 10 mmthick in CM (1:6) on other side of lathing complete all as specified and directed. |
| 27 | M&L forpreparation of newly plastered surfaces of walls and applyingtwo coats of cement base paint complete all as specified and as directed. |
| 28 | Preparing new plastered surfaces and applying two coats of oil bound distemper over chalk whitening complete all as specified and directed. |
| 29 | Taking down chowkat with shutters of any description without taking off shutters from frame area exc 1.50 Sqm but not exc 4.00 sqm complete all as specified and directed. |
| 30 | All as per item No. 29 here-in-before but area not exc 1.50 sqm each complete all as specified and directed. |
| 31 | Taking down shutter of any description n.exc 1.00 Sqm each complete all as specified and as directed. |
| 32 | Taking down shutter of any description exc 1.00 Sqm and n.exc 2.0 Sqm each complete all as specified and as directed. |
| 33 | Refixing door shutter in same opening exc 1.00 Sqm and n exc 2.00 Sqm each complete all as specified and directed. |
| 34 | S&F for second class hard wood plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete as making good to wall complete all as specified and directed. |
| 35 | S&F framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework or water tanks and similar work confirming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 36 | S&F for 35mm thick factory made, IInd class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 37 | S&F 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc divided in square with plain, chamfered or rounded mitred and rebated sash bars any number, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, complete all as specified in SSR Part I section 8, clause 8.24 (a) fitted to chowkat complete all as specified and directed. |
| 38 | S&F steel window with side hung shutters including boxtype hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or weldedand necessary arrangements to fixed with wooden scantling/supports etc complete all as specified in SSR-2020 part I & II and as directed. |
| 39 | S&F steel window with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including guard bars/grills and necessary arrangements to fixed with wooden scantling/supports etc complete all as specified in SSR-2020 part I & II and as directed. |
| 40 | S&F steel ventilators with top hung shutters including hinges steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified in SSR-2020 part I & II and as directed. |
| 41 | S&F 30mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 42 | S&F for solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube in opening, complete all as specified and as directed. |
| 43 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for styles and plain colour PVC sheet for top rail ,lock rail & bottom rail on either sides and as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading, and joint together with solvent cement, complete all as specified and as directed. |
| 44 | S&F galvanized mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks, or galvanized wire staples. stainless steel wire staples complete all as specified and directed. |
| 45 | All as per item No. 44 here-in-before but fixed in repairs complete all as specified and directed. |
| 46 | S&F 3mm thick sheet glass ordinary quality in square n.exc 0.5 Sqm in each pane complete all as specified and directed. |
| 47 | All as per item No. 46 here-in-before but fixed in repairs complete all as specified and directed. |
| 48 | S&F for 200 mm long anodized aluminium barrel tower bolt of extruded section complete all as specified and as directed. |
| 49 | S&F for 100 mm long anodized aluminiumbarrel tower bolt of extruded section complete all as specified and as directed. |
| 50 | S&F 150 mm long anodized aluminium handles, cast type complete all as specified and as directed. |
| 51 | S&F 100 mm long anodized aluminium handles, cast type complete all as specified and as directed. |
| 52 | S&F 100 mm butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed. |
| 53 | S&F 75 mm butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed. |
| 54 | S&F 300mm long aluminium anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 55 | S&F MS 300 mm, ordinary rat rail tail, rod pattern springs, including roller and roller plate (Helical door spring)complete all as specified and directed. |
| 56 | S&F in repair MS 300 mm, ordinary rat rail tail, rod pattern springs, including roller and roller plate (Helical door spring)complete all as specified and directed. |
| 57 | S&F in repairs water closet (Squatt Pattern) complete including provision of cement concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc and making good to floor complete all as specified and directed. |
| 58 | S&F in repairs PVC High/Low level flushing cistern 10 litres capacity including all fittings i.e. float valve, siphon, flush pipe, brackets complete all as specified and directed. |
| 59 | S&F in repair PVC connections 15mm dia with brass nut on both ends and washers 450mm long complete all as specified and directed. |
| 60 | S&F in repairs bib taps CP brass fancy type with crutch or butterfly handle screwed down screwedfor iron pipe for brass ferrule 15 mm dia complete all as specified and directed. |
| 61 | S&F in repair stop valves cast copper alloy chromium plated fancy type, screwed down, high pressure with butterfly handle, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and directed. |
| 62 | S&F in repairs PVC (SWR) floor trap, 75 mm size plain with grating including jointing with solvent cement complete all as specified and directed. |
| 63 | S&F tubes 15mm bore medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor concealed / at face etc complete all as specified including taking up or down steel tubing and connections complete all as specified and directed. |
| 64 | S&F tubes 20 mm bore medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor concealed / at face etc complete all as specified including taking up or down steel tubing and connections complete all as specified and directed. |
| 65 | S&F in repair vitreous china wash hand basin, (white), flat back of size 550x400 mmwith and including two CI brackets, brass chromium platedincluding waste coupling fittings andPVC waste pipe complete all as specified and as directed. |
| 66 | S& Fin repairs 15 mm size fancy type pillar taps, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered `Hot or Cold\" with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 67 | S&F in repair 600 x 450 mm and 5 mm thick bevelled edge mirror of selected quality glass mounted on 6 mm thick commercial ply woodand fixed wooden plugs with CP brass screws and cup washers complete all as specified and directed. |
| 68 | M&L for preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 69 | M&L for preparation of new or previously untreated surfaces of steel of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paintover a coat of red oxide primer complete all as specified and directed. |
| 70 | Demolition of cement concrete in ground floors and pavings n. exc. 15 cm thick (below or above ground level) complete all as specified and directed. |
| 71 | M&L for 40 mm thickPCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in floors finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 72 | M&L for 75 mm thickPCC 1:3:6 type C-2 (using 40 mm graded aggregate) as in plinth protection complete all as specified and directed. |
| 73 | M&L for PCC(1:4:8) type D2 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 74 | M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate for bearing/bed plates, copings, kneelers, apex stones, kerb stones etc including weathering, slightly rounded or chamfered angles and throating complete all as specified anddirected. |
| 75 | Dismantling floor hearth and wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises, complete all as specified and directed. |
| 76 | M&L for glazed coloured ceramic tiles of size 450 x 300 x 7 mm thick on vertical surfaces, set and jointed in neat cement slurry and pointed with white cement to match the coloured tiles including 10 mm thick rendering in CM (1:4) for vertical sub base complete all as specified and directed. |
| 77 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floor etc and jointed in neat cement slurry and pointed in white cement or coloured cement to match the shade of tile over and including 15 mm thick screed bed layer in CM (1:6) al as specified and directed. |
| 78 | All as per item No. 77 here-in-before but on dado/skirting over 10 mm thick plastering in CM(1:4) complete all as specified and directed. |
| 79 | M&L for Vitrified ceramic tiles 10 mm thick dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed layer in CM (1;6) all as pd and as directed. |
| 80 | All as per item No. 79 here-in-before but on dado/skirting over 10 mm thick plasteringin CM(1:4) complete all as specified and directed. |
| 81 | M&L for PCC (1:2:4) type B-1, (Using 20 mm graded aggregates) 25 mm thick as in levelling course / sub base complete all as specified and directed. |
| 82 | M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed. |
| 83 | M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick screed bed in CM (1:4) complete all as specified and directed. |
| 84 | Taking down carefully existing bituminous felt including plaster lime or concrete of any thickness, and cleaning of the surface of roofs, terrace including flushing and junction of parapets, kerb walls, PCC fillets benching etc. with wire brushes and removing of rubbish outside ministry of defence land of any lead of complete all as specified and directed. |
| 85 | M&L for rendering 10mm thick on existing concrete surfaces of roof in CM (1:3) mixed with water proofing compound @ 3% by weight of cement finishing even and smooth to receive water proofing treatment complete without using extra cement at any height all as specified and directed by Engineer-in-Charge.Note:- WPC shall be measured and paid for separately. |
| 86 | M&L for one coat of applied bituminous primer over cleaned surface @ 0.30 Ltr per sqm and over one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/ Sqm over bituminous primer then followed by APP modified five layer polymeric membrane 3 mm thick minimum weight 3.6 Kg per Sqm reinforced with polyester non woven fabric (weighting not less than 150 gm per sqm) laid as per the manufacturer\"s instruction with side over lap of 75 mm and end over lap of 100 mm and applying one coat of polymeric modified bitumen 85/25 @ 1.20 Kg per Sqm complete all as specified and directed. |
| 87 | Supply only integral water proofing compound complete all as specified and directed. |