| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. |
| 3 | Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 4 | Supplying andFILLING GRAVELin \"foundation andbasementin layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. |
| 5 | Supplying and filling in foundation, basement, etc with filling stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 6 | Supplying and filling 40mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc. complete complying with standard specification. |
| 7 | Supplying and filling 20mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc. complete complying with standard specification. |
| 8 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification |
| 9 | Brick work in Cement Mortar 1:5, using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification. |
| 10 | For Foundation and Basement |
| 11 | Ground floor |
| 12 | Brick work in Cement Mortar 1:6, using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification. |
| 13 | For Foundation and Basement |
| 14 | Ground floor |
| 15 | First Floor |
| 16 | Second floor |
| 17 | Third floor |
| 18 | Brick work in Cement Mortar 1:3, using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification. |
| 19 | For Foundation and Basement |
| 20 | Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification. |
| 21 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 22 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) |
| 23 | For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, and beams, etc. |
| 24 | For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. |
| 25 | For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. |
| 26 | For circular columns |
| 27 | Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. |
| 28 | For every one meter above 3.30m |
| 29 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 30 | For Foundation and Basement |
| 31 | Ground floor |
| 32 | First Floor |
| 33 | Second floor |
| 34 | Third floor |
| 35 | Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m\") 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 36 | In First Floor |
| 37 | In Third Floor |
| 38 | Providing and laying in position, Standardised Concrete Mix M-35 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m\") 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 39 | In Ground Floor |
| 40 | In First Floor |
| 41 | In Second Floor |
| 42 | Post Tensioning Work:Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting,packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer Architect but excluding shuttering, concretin & reinforcement steel which shall be payable under respective items separately. |
| 43 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 44 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 45 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 46 | Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three crushed stone sand and Six hard broken stone jelly).Dummy columns should be at least 1 metre height) |
| 47 | For First floor |
| 48 | Paving the Top of roof with Solar reflective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by the Executive Engineer before use on works) |
| 49 | Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying,consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers |
| 50 | Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 51 | Foundation and basement |
| 52 | Ground floor |
| 53 | First Floor |
| 54 | Second floor |
| 55 | Providing granolithic floor finish of theplain cement concrete 1:2:4 (One Cement, Two crushed stone sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) |
| 56 | 25 mm thick |
| 57 | Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and threecrushed stonesand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 58 | Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stonesand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 59 | Providing full nosing to the steps or platforms to the granite slab of 20mm thick including neat finishing,polishing ,cost of powder,tools etc. as directed by the departmental officers.Single nosing |
| 60 | Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 61 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 62 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 63 | Dadooing walls with following best approved quality, Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 64 | Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed by the departmental officers. |
| 65 | 38 / 40mm thick |
| 66 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the Departmental officers |
| 67 | 50mm thick slab (using 20mm HBGS Jelly) |
| 68 | 75 mm thick slab using 20 mmm/c stone jelly |
| 69 | Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications |
| 70 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 71 | 160 mm dia PVC pipe |
| 72 | 110 mm diaPVC pipe |
| 73 | Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place.Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete. |
| 74 | Single Leaf |
| 75 | Supplying ,fabricating and fixing in position of Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1 mm thick) of size 100 mm x 60 mm with a rebate of 30 / 35 mm x 15 mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel Hold fast etc.,complete as directed by the departmental officers in all floors. |
| 76 | Fabricating supplying and fixing in position M.S Steel framed door with weldmesh and fine wire mesh netting etc. with necessary locking facilities and hinges including cost of red oxide primer etc., complete as directed by the departmental officers. |
| 77 | Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround Teak ply 3mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .300x12mm aluminium tower bolt 2nos. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. |
| 78 | Single Leaf |
| 79 | Double Leaf |
| 80 | Supplying and erecting pull and push type rolling shutter Manually operated with ISI make of approved size and section using 18 GI sheet.The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc., |
| 81 | SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profilethe size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 82 | SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 83 | Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm.The over all size of top rail,Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. Solid panel PVC door with frame |
| 84 | Supplying and fixing PVC sliding door for DifferentlyAbledpersons toilet inwith Solid PVC door shuttersusing 19 Gauge 19mm MS square tubes for styles and outer frames,15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm.The over all size of top rail,Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter including slidng arrangements. |
| 85 | Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed atalllevelelevationandheights. Theextrudedsection cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25+ 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer |
| 86 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mmfromfinishedfloorlevelweldedto38mmdia StainlessSteelpipepostof1.00mmthick asverticalat 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 87 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of25mmdiaof1.60mmthickweldedtotherailing. Thesupports will be groutedinto the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supportingarrangementsthehandrailinfloor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 88 | Supplying and fixing MS Grill for Doors, Windows and Ventilators using required MS angles, flatsetc complete complying with standard specification. The type design for the grills should be got approved by the departmental officers before execution. |
| 89 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three P-sand), 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement and with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 90 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three P-sand), 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement and with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 91 | Plastering with Cement Mortar 1:5 (One cement and Five P-sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 92 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P-Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 93 | Painting two coats of newly plastered wall surface with ready mixed plastic interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 94 | Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 95 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 96 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 97 | Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. |
| 98 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 99 | 50mm Dia Gun metal Gate Valve |
| 100 | 40mm Dia Gun metal Gate Valve |
| 101 | 32mm dia GM gate valve: |
| 102 | 25mm dia GM gate valve: |
| 103 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) |
| 104 | Cp Screw down tap |
| 105 | Swan neck tap |
| 106 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 107 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 108 | Supplying and fixing best approved best quality Procelain CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). |
| 109 | Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works). |
| 110 | Supplying and fixing best approved best qualityStainles steelHealth Facetwith Stop coak of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). |
| 111 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 112 | Supplying and fixing in position best quality approved make white glazed earthernwere sink of size of 600 x 450 x 200mm including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets.[The sink and specials should be got approved by the Executive Engineer before use on works] |
| 113 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). |
| 114 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings..... |
| 115 | Supplying and fixing position PVC Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three P-sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 116 | Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) |
| 117 | White glazed earthernwere lipped mouth flat back urinal |
| 118 | Supplying and fixing in position Indian make white glazed earthenware squating type urinal of best quality and approved make including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The squatting urinal should be got approved by the Executive Engineer before use on works). |
| 119 | Supplying and fixing the Incinerator for Ladies Bathroom (For School Works) completeetc.,complying with standard specification. |
| 120 | Supplying, laying and jointing glazed stone ware pipes of the following dia of approved quality with spigot and socket ends and fixing them in dry condition using spun yarn and cement including petty masonry shoring and strutting wherever found necessary and laying the pipe line in the alignment at the specified gradient and testing with necessary tools and plants, etc., and re-filling the trench with excavated earth and levelling the ground etc.,complete complying with standard specifications.(Earth work excavation, re-filling with excavated earth will be measured and paid separately). |
| 121 | 100mm dia stoneware pipe (cement joint) |
| 122 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid Above ground level |
| 123 | 110mm dia PVC Pipe |
| 124 | 75mm dia PVC Pipe |
| 125 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 126 | 160 mm dia PVC Pipe |
| 127 | 110 mm Dia PVC Pipe |
| 128 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 129 | 110mm dia PVC Elbow with Door |
| 130 | 75mm dia PVC Elbow with Door |
| 131 | 110mm dia PVC Y |
| 132 | 75mm dia PVC Y |
| 133 | 110mm dia PVC plain bend |
| 134 | 75 mm dia PVC plain bend |
| 135 | 110 mm PVC Tee |
| 136 | 75 mm PVC Tee |
| 137 | Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers |
| 138 | Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works. Below ground level. |
| 139 | 32 mm dia |
| 140 | 25mm dia |
| 141 | Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on worksAbove ground level. |
| 142 | 50 mm dia |
| 143 | 40 mm dia |
| 144 | 32 mm dia |
| 145 | 25 mm dia |
| 146 | 20mm dia: |
| 147 | Supplying CPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements |
| 148 | 50mm diaCPVC Elbow |
| 149 | 40mm diaCPVC Elbow |
| 150 | 32mm diaCPVC Elbow |
| 151 | 25mm diaCPVC Elbow |
| 152 | 20mm diaCPVC Elbow |
| 153 | 50mm diaCPVC Tee |
| 154 | 40mm diaCPVC Tee |
| 155 | 32mm diaCPVC Tee |
| 156 | 25mm dia CPVC Tee |
| 157 | 20mm diaCPVC Tee |
| 158 | 50mm diaCPVC Union |
| 159 | 40mm diaCPVC Union |
| 160 | 32mm diaCPVC Union |
| 161 | 25mm diaCPVC Union |
| 162 | 20mm diaCPVC Union |
| 163 | 25mm dia CPVC Bend |
| 164 | 20mm diaCPVC Bend |
| 165 | Manufacturing, supplying and fixing of Teakwood ornamental Entrance door of size 1.80x2.40m with the following specification. The outer frame of ornamental Entrance Door of size 150x100mm.Teak wood scantling.The door consists of openable area 1.60x2.20m with Double leaf. The each openable shutter consists of Top Panel for 1.50m.height and bottom vertical pannel in for a height of 90cm. The Shutter bottomrail is of 200x50mm.size and middle, top and side rails are of size 150x50mm.with corner designed beading works.The shutter pannel is of 40mm. thick T.W.planks with special curving works.The outer frames corners are designed border works single side for entrance outer frame and on both sides for middle frame..The cost includes all kinds of furniture fittings, such as Brass Aldrop, Brass tower bolt, brass hinges, brass door stopper, brass handles.All the members are finshed with two coats of melamine polish outer the priming coat. |
| 166 | Supplying and laying of Interlocking Paver Block Stone 60mm thk. Over a base layer of sand filling incl. Cost of materials laying and Labour charges etc., |
| 167 | Manufacturing, supplying and fixing of cupboard shutter using country wood (kongu) frame of 100 m x 32 mm thick for outer frame horizontal and vertical memebers. The shutter frame of size 75 x 32 mm of country wood scantling (Horizontal 3 nos., Vertical 2 nos., of reach shutter) with 12 mm thick both side prelaminated particle board (exterior grade) shutter.The shutter are fixed to the frame with requied 6 nos., o alumium hings 100 x 30 mm 2 nos., \"D\" type alumium hadle 100 mm 2 nos., of aluminum tower bolts 75 x 10 mm 2 nos., of cupboard lock etc., the country wood frame shall be painted two coats with synthetic enamel paint over one coat of wood primer. The prelaminated particle board and furniture fittings used should be got approved by the Executive Engineer before use on works. The cost is inclusive of alumnum handle. tower bolts, piano type hingers, screws, nails, and required further fittings and painting the frame and inner side of prelaminate shutter etc., complete complying with standard specification. |
| 168 | Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes inRCC column,masonrywherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing as directed by the departmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineerbefore use. |
| 169 | Fabricating Supplying and fixing in position of Aluminium anodised Powder Coated of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made ofsection Vertical & Top rail: [email protected] kg/m and Bottom rail: 100x44.45x2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 1 Nos., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bushincluding cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete.All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge. |
| 170 | Supplying, fabricating, erecting and fixing Hilux (or) equivalent board false ceiling upto a ceiling height of 4.5m from floor level.etc complete with standard specification and as directed by the Departmental officers |
| 171 | Providing Cornice Work for Gyp Board False Ceiling etc complete with standard specification and as directed by the Departmental officers |
| 172 | Providing and fixing Acoustic wall Panelling (equivalent ot Armstrong ) in channelled wood works perforated panels of width 192mm, thickness of 15mm and length of 2400mm or as per required by the Departmental Engineer made of a high density fibre board with minimum 725 kg./m3 density substrate with a laminated facing as per the approved shade and finish and a melamine balancing layer on the reverse side. The boards shall have a special peforation pattern where the visible surface has a \"Helmholtz\"fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be \"tongue\" and grooved\"to receive special clips for installation. The back of the perforated panel shall have sound absorbing not woven acoustical fleese having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Engineer-in-Charge |
| 173 | Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. |
| 174 | Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed |
| 175 | Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed |
| 176 | Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed. |
| 177 | Supplying and Fixingin position of PVC water storage tank of best approved quality and brand of super thick with the 1000 litres capacity with acessories includinggiving necessory connections etc complete. |
| 178 | Supplying and erecting in position of following 500 liters capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact |
| 179 | Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five crushed stone sand] using best quality of second class Table Mould Bricks of size 9\" x 43/8\" x 23/4\" with Plastering with Cement Mortar 1:3 [One Cement and Three P-Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. |
| 180 | Supplying and laying of 600mm dia RCC Hume Pipe including all accessories and as directed by the departmental officers etc complete |
| 181 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 150mm dia and then enlarging to required dia direct or reverse Specialrotary mud circulation method using rotary Specifications rigs, fuel, labour and drilling bentonite and water required for drilling at site(Site will be shown by the TWAD Board Officers) including construction of mud pit. |
| 182 | Up to 60M depth below ground level |
| 183 | From 60m - 90m Depth ending below ground level |
| 184 | From 90 m upto 120 m Depth ending from ground level |
| 185 | From 120 m upto 150 m Depth ending from ground level |
| 186 | Reaming 150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officers. |
| 187 | Up to 60M depth below ground level |
| 188 | From 60m - 90m Depth ending below ground level |
| 189 | From 90 m upto 120 m Depth ending from ground level |
| 190 | From 120 m upto 150 m Depth ending from ground level |
| 191 | Supplying and fixing PVCcasing pipes of 150mm dia vertical10Kg/Cm2 in sedimentarydepth asdirected by the departmental officers etc., complete. |
| 192 | 150mm dia PVC plain pipe |
| 193 | 150 mm PVC pipe with slotted |
| 194 | Labour charges for inseting casingpipesassemble (with slots and without slots)in the drilled holds including weldingthe joints etc. complete and supplyingand placing ofthe angular with pebbles of size and quality as approved by the E.E., PWD., |
| 195 | Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by ‘V’ notch method. |
| 196 | Bore cap 150mm dia size using M.S. Flat of size 1 cm x 3 mm and M.S. sheet on top with bolting arrangements for securing the cap in position (Bore caps with M.S. Couplings need not be made) |
| 197 | Supplying and fixing of 32mm dia HDPE pipes for sub mersible pump in bore well class-5 1Mpa or 10 kg. / cm2 pressure) |
| 198 | Supply of 2.5 sq.mm. three core flat copper cable for submercible motor pump with wire bounded punched copper conductor insulated and sheathed with PVC with voitage grate upto 1100v confirming to and marked with is (694-1990) complying with standrad etc., complete |
| 199 | Supplying and fixing of 2.00 HP Submerssible motorwith ISI Mark 14 stage with pump |
| 200 | Supply and fixing of panel board item for the following motor pump with fully automatic starter phase preventor,on & off switch indicator lamp, volta meter and ammeter with selector switch with suitablepower capacity arranded in a steel sheet box as directed by the deparmental office ect.,complete |
| 201 | Supplying and fixing Nylon Rope for Bore-well andas directed by the department officers. |
| 202 | Supplying and Fixing of 1.00 Hp Mono blockmotor including all accessories as directed by the departmental officers etc complete |
| 203 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wireconnection of 14 SWG TC wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point(5 points / Coil) (Higher End) |
| 204 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point(6 points / Coil) (Higher End) |
| 205 | Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point . (Higher End) |
| 206 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil). Higher End |
| 207 | Supply and fixing of single box type 4\"-20 W LED fitting (Philips / Havells / Eq) with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed Copper leads from terminals to the fitting. |
| 208 | Supply and fixing of 1200mm (48\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher End) with 300 mm down rod on the existing fan clamp. |
| 209 | Supply and fixing of 16\"(400 mm)wall mounting fan (Orient Electric Wall-49) with remote with suitable clamps and necessary conections complete. |
| 210 | Supply and fixing of 24W TRIM CLIPON LED (Havells make / Eq) Recess Cum surface mounting squaretype fitting of cool white outputwith integral driver and necessary connections complete. |
| 211 | Supply and fixing of square type recessed 2\" x 2\" 36W LED luminaire (Philips / Havells / Eq) on false ceiling with steel chain and PVC unsheathead copper leads from terminals to the fitting. |
| 212 | Supply and fixing of Twin box type 4\"- 20W LED fitting (Philips / Havells / Eq) with CRCA body complete with conduit pipe suspension from the ceiling with PVC unsheathed Copper leads from terminals to the fitting with 2 nos of 20W LED tubes. |
| 213 | Supply and fixing of 300 mm (12\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. |
| 214 | Supply and fixing of louvers shutters arrangements for 300mm (12”) sweep (light duty) AC Exhaust fan. |
| 215 | Supply and fixing of 9W LED lamp (Havells / Eq) in existing BH point. |
| 216 | Supply and fixing of WT bulk head fitting with guard suitable for 9W LED lamp(Havells /Eq) with lamp. |
| 217 | Supply and fixing of 70W LED street light fitting with LED (Havells / Eq) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting. |
| 218 | Supply & Fixing of AC / DC 76mm Buzzer /call bell suitable for 230 Volts 50 c/s single phase AC supply on suitable TW round block with1 Module GI flush mounting box, 1 Module combined plastic cover plate and 1 module Modular type Bell push Switch with indicator complete (The GI flush mounting box,cover plate and switch should be ofLegrand/ Hager/ Crabtree/ Equilvalent). |
| 219 | Supply and fixing of 25 litres capacity 1000W automatic electric water heater with copper container with glass wool / Puf insulation with MS powder coated shell (VENUS/RACOLD) with ISI mark suitable for 230V 50 c/s AC supply on suitableMS clamps with 3 core flex wire but without plumbing work. |
| 220 | Supply and fixing of 3nos.6A two module 5 pin socket, 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. (Higher End) |
| 221 | Supply and fixing of 1 no.6/16A two module socket, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. (Higher End) |
| 222 | Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) (Legrand/ Hager make) |
| 223 | Supply and fixing of 32A DP MCB in sheet enclosure in flush with wall with earth connection. (The MCB and metal enclosure should be with Legrand/ Hager make). |
| 224 | Supply and fixing of 63A FP MCB in sheet enclosure in flush with wall with earth connection. (The MCB and metal enclosure should be with Legrand/ Hager make). (For Ductable AC unit and UPS input and output) |
| 225 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with IP 42 protection with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. (Higher End) |
| 226 | Supply and fixing of 7 segment 4 way triple pole neutral MCB distribution boardin sheet steel enclosure double door type with metal door with IP 43 - IK 09protection with 40A 4 pole MCB as incoming and 3Nos 40A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (The MCBDB andMCB\"s should be with Legrand / Hager make) |
| 227 | Supply and fixing of 7 segment 4 way triple pole neutral MCB distribution boardin sheet steel enclosure double door type with metal door with IP 43 - IK 09protection with 63A 4 pole MCB as incoming and 3Nos 63A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (The MCBDB andMCB\"s should be with Legrand / Hager make) |
| 228 | Supply and fixing of 7 segment 4 way triple pole neutral MCB distribution boardin sheet steel enclosure double door type with metal door with IP 43 - IK 09protection with 100A 4 pole MCB as incoming and 3Nos 100A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (The MCBDB andMCB\"s should be with Legrand / Hager make) (AC Plug ) |
| 229 | Supply and fixing of Vertical type 4 way triple pole neutral MCB distribution boardin sheet steel enclosure double door type with metal door with IP 43 - IK 09 protection with 100A 4 pole MCB as incoming and 4Nos 63A TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (The MCBDB andMCB\"s should be with Legrand / Hager make) |
| 230 | Supply and fixing of Vertical type 4 way triple pole neutral MCCB distribution boardin sheet steel enclosure double door type with metal door with IP 43 - IK 09 protection with 125A 4 pole MCCB as incoming and 4Nos 63A TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (The MCCBDB andMCB\"s should be with Legrand / Hager make) (Auditorium) |
| 231 | Supply and run of 2 of 1.5sq.mm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling making good of the concealed portion with suitable colour. |
| 232 | Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade insuitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour. |
| 233 | Supply and run of 2 of 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour. |
| 234 | Supply and run of 4 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour. |
| 235 | Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour. |
| 236 | Supply and run of 4 x 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 32mm dia GI pipe (Class \"B\") suitably bent at both ends with necessary angle iron up right and end supports for mains |
| 237 | Supply and run of 4 x 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains. |
| 238 | Desgin, Fabrication, Supply, testing and commissioningof800 Amps cubical panel floor mounting type dust and vermin proof MV panel boardof size 14\" x 7\" x3\" made up of 18 SWG CRCA sheet steel rated for 433 V, 50 HZ AC supply as per the CEIG guidelines and latest IE rules comprising the following: |
| 239 | Main Busbar:- 2 runs of 2\" x 1/4\" copper flat for 3 phases and 1 run of 1\" x 1/4\" copper flat for neutral. |
| 240 | EB Incomer: 800A,4 pole, 433V 50kA Thermal magnetic based MDO Air Circuit Breaker with protection and interlock arrangements as per relevant IS with latest amendments - 2 Nos (L&T/Siemens make) |
| 241 | Buscoupler: 800A,4 pole, 433V switch with interlock arrangements as per relevant IS with latest amendments - 1 No (L&T/Siemens make) |
| 242 | 1. Manual trip push button - 3Nos |
| 243 | 2. Mechanical ON/OFF indicator - 3Nos |
| 244 | 3. Vertical Terminal Adaptors - 9Nos 4. LED indicating lamp-9 Nos |
| 245 | 5. Under Voltage Releasefor 433 volts AC - 2Nos |
| 246 | 6. No/NC auxiliary contacts-2sets |
| 247 | 7. CTs suitable for metering - 2 sets |
| 248 | 8. Digital demand controller- 2Nos |
| 249 | 9. Earth Fault Release Type EF1 (10%, 20% In ) - 2Nos |
| 250 | 10. Over current relay - 2Nos |
| 251 | 11. Shunt Release for 433 volts AC - 2Nos |
| 252 | 12.suitable capacity fuse controls for the systems - 2sets 13. 3 lock 2 key arrangements14. Multifunction meter - 2 nos to display phase voltages, Line voltages, Power factor, Phase current, frequency |
| 253 | Separate mould base for each pole for easy maintenance, all relevant protection, accessories, as per CEIG IE rules in force, with interconnection and terminations and required. |
| 254 | Outgoing switches:1. 400Amps TPN interior switch fuse disconnector with HRC fuse double break -4 Nos (L&T / Siemens make) |
| 255 | 2. 200Amps TPN interior switch fuse disconnector with HRC fuse double break - 4 Nos (L&T / Siemens make) |
| 256 | The following tinned Cu flat should be used between busbar and switches: 2\"x1/2\" tinned cu. Flat for interconnection of 2 Nos 800A FP incoming ACB & 1no 800A FP switch buscoupler and 2\"x1/4\" tinned cu. Flat for interconnection of 4 Nos 400A TPN outgoing switches & 1\"x1/4\" tinned cu. Flat for interconnection of 4 Nos 200A TPN Outgoing switches. The EB supply feeder are to provide with digital multifunction meter with CT, RYB indicator lamp and control fuses switches S&F of danger borad all switches and the ACB\"s should be given double earth connection by runs of 25x3mm copper flat and two numbers 25 x 3 copper earth bus must be run around the panel as per IE rules. |
| 257 | All live parts of the bus switches etc are to be shrouded with suitable 6mm thick hylum sheet and SMC support insulators should be with maximum creep age distance as per IE rules.All the out going feeder, bus bars should be extended for easy termination of LTUG cable and suitable removable type gland.All the copper flats inside the panel should be provided with heat shrinkable sleeves and lead coating in the termination points. |
| 258 | The cubical panel should be mounted over the MS channel of size 3\" x1 1/2\" x 1/2\".The cubical panel should be painted with anti corrosive red oxide and with powder coated epoxy paint. The capacity of the switch, cable direction, place of feeding shall be indicated clearly in all theswitches. The operation and maintenance manual for the metering instruments and the AB switches shall be handed over to the department without fail. |
| 259 | Supply, fabrication, erection and comissioning of 400A capacity dust and vermin proof cubical panel board size of 7\"X 1\" X 5.5\"made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interiorswitch with bus bar chamber complete with |
| 260 | 1\" x 1/2\" tinned cu. Flat for 3 phase, 1 \" x 1/4\" tinned cu flat forneutral, 1\" x 1/8\" tinned cu flat forearth connectionswith bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches:1\" x 1/2\" tinned cu. Flat for interconnection of 1No 400A incoming switch to bus bar, 1\" x 1/8\" tinned cu. Flat for interconnection of 6 Nos 125A Outgoing switches to bus bar, andno.8 SWG Copper conductort for interconnection of 6 Nos 63A outgoing Switches to bus bar. |
| 261 | A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 13 Nos 3 phase switches and supply & fixing of the following switches. |
| 262 | 1.400 A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1No2. 125A TPNswitch disconnector fuse units interior only with HRC fuses double break - 6Nos3. 63A TPNswitch disconnector fuse units interior only with HRC fuses double break - 6Nos |
| 263 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications.The earth bus with two runs of 1\" x 1/8\" tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted withtwo high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3\"x1½\"x½\" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (Auditorium power) |
| 264 | Supply, fabrication, erection and comissioning of 400A capacity dust and vermin proof cubical panel board size of 5\"X 1\" X 5.5\"made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interiorswitch with bus bar chamber complete |
| 265 | with 1\" x 1/2\" tinned cu. Flat for 3 phase, 1 \" x 1/4\" tinned cu flat forneutral, 1\" x 1/8\" tinned cu flat forearth connectionswith bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches:1\" x 1/2\" tinned cu. Flat for interconnection of 1No 400A incoming switch to bus bar,1 1/4\" x 1/4\" tinned cu. Flat for interconnection of 1 No 315A Outgoing switches to bus bar, 1\" x 1/4\" tinned cu. Flat for interconnection of 3 Nos 200A Outgoing switches to bus bar and 1\" x 1/8\" tinned cu. Flat for interconnection of 2 Nos 100A Outgoing switches to bus bar. |
| 266 | A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 7 Nos 3 phase switches and supply & fixing of the following switches. |
| 267 | 1.400 A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1No2. 315A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1Nos 3. 200A TPNswitch disconnector fuse units interior only with HRC fuses double break - 3Nos4. 100A TPNswitch disconnector fuse units interior only with HRC fuses double break - 2Nos |
| 268 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications.The earth bus with two runs of 1\" x 1/8\" tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted withtwo high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3\"x1½\"x½\" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (Admin total power) |
| 269 | Supply, fabrication, erection and comissioning of 400A capacity dust and vermin proof cubical panel board size of 6\"X 1\" X 5.5\"made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interiorswitch with bus bar chamber complete |
| 270 | with 1\" x 1/2\" tinned cu. Flat for 3 phase, 1 \" x 1/4\" tinned cu flat forneutral, 1\" x 1/8\" tinned cu flat forearth connectionswith bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches:1\" x 1/2\" tinned cu. Flat for interconnection of 1No 400A incoming switch to bus bar,1\" x 1/4\" tinned cu. Flat for interconnection of 4 Nos 200A Outgoing switches to bus bar, 1\" x 1/8\" tinned cu. Flat for interconnection of 2 Nos 125A Outgoing switches to bus bar and no.8 SWG copper conductor for interconnection of 2 Nos 63A Outgoing switches to bus bar. |
| 271 | A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 9 Nos 3 phase switches and supply & fixing of the following switches. |
| 272 | 1.400 A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1No2. 200A TPNswitch disconnector fuse units interior only with HRC fuses double break - 4Nos 3.125A TPNswitch disconnector fuse units interior only with HRC fuses double break - 2Nos4. 63A TPNswitch disconnector fuse units interior only with HRC fuses double break - 2Nos |
| 273 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications.The earth bus with two runs of 1\" x 1/8\" tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted withtwo high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3\"x1½\"x½\" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (250kVA Genset panel) |
| 274 | Supply, fabrication, erection and comissioning of 315A capacity dust and vermin proof cubical panel board size of 7\"X 1\" X 5\"made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interiorswitch with bus bar chamber complete with |
| 275 | 1 1/4\" x 1/4\" tinned cu. Flat for 3 phase, 1 \" x 1/4\" tinned cu flat forneutral, 1\" x 1/8\" tinned cu flat forearth connectionswith bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches:1 1/4\" x 1/4\" tinned cu. Flat for interconnection of 1No 315A incoming switch to bus bar, 1\" x 1/8\" tinned cu. Flat for interconnection of 5 Nos 100A Outgoing switches to bus bar, and , no.8 SWG Copper conductort for interconnection of 7 Nos 63A outgoing Switches to bus bar. |
| 276 | A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 13 Nos 3 phase switches and supply & fixing of the following switches. |
| 277 | 1.315 A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1No2. 100A TPNswitch disconnector fuse units interior only with HRC fuses double break - 5Nos3. 63A TPNswitch disconnector fuse units interior only with HRC fuses double break - 7Nos |
| 278 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications.The earth bus with two runs of 1\" x 1/8\" tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted withtwo high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3\"x1½\"x½\" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (Admin GF power) |
| 279 | Supply, fabrication, erection and comissioning of 200A capacity dust and vermin proof cubical panel board size of 5\"X 1\" X 4.5\"made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interiorswitch with bus bar chamber complete with |
| 280 | 1\" x 1/4\" tinned cu. Flat for 3 phase, 1\" x 1/8\" tinned cu flat forneutral, 1\" x 1/8\" tinned cu flat forearth connectionswith bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches: 1\" x 1/4\" tinned cu. Flat for interconnection of 1No 200A incoming switch to bus bar and no.8 SWG copper conductor for interconnection of 10 Nos 63A Outgoing switches to bus bar. |
| 281 | A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 11 Nos 3 phase switches and supply & fixing of the following switches. |
| 282 | 1.200A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1No2. 63A TPNswitch disconnector fuse units interior only with HRC fuses double break - 10Nos |
| 283 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications. The earth bus with two runs of 1\" x 1/8\"tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted withtwo high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3\"x1½\"x½\" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (Admin Lighting & 2F power) |
| 284 | Supply, fabrication, erection and comissioning of 200A capacity dust and vermin proof cubical panel board size of 5\"X 1\" X 4.5\"made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interiorswitch with bus bar chamber complete with |
| 285 | 1\" x 1/4\" tinned cu. Flat for 3 phase, 1\" x 1/8\" tinned cu flat forneutral, 1\" x 1/8\" tinned cu flat forearth connectionswith bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches: 1\" x 1/4\" tinned cu. Flat for interconnection of 1No 200A incoming switch to bus bar, 1\" x 1/8\" tinned cu. Flat for interconnection of 3 Nos 100A Outgoing switches to bus bar, no.8 SWG copper conductor for interconnection of 5 Nos 63A outgoing Switches to bus bar. |
| 286 | A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 9 Nos 3 phase switches and supply & fixing of the following switches. |
| 287 | 1.200A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1No2. 100A TPNswitch disconnector fuse units interior only with HRC fuses double break - 3Nos3. 63A TPNswitch disconnector fuse units interior only with HRC fuses double break - 5Nos |
| 288 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications. The earth bus with two runs of 1\" x 1/8\"tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted withtwo high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3\"x1½\"x½\" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (Admin 1F power) |
| 289 | Supply, fabrication, erection and comissioning of 200A capacity dust and vermin proof cubical panel board size of 5\"X 1\" X 5.5\"made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interiorswitch with bus bar chamber complete with |
| 290 | 1\" x 1/4\" tinned cu. Flat for 3 phase, 1 \" x 1/8\" tinned cu flat forneutral, 1\" x 1/8\" tinned cu flat forearth connectionswith bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches:1\" x 1/4\" tinned cu. Flat for interconnection of 1No 200A incoming switch to bus bar, 1\" x 1/8\" tinned cu. Flat for interconnection of 4 Nos 125A Outgoing switches to bus bar, andno.8 SWG Copper conductort for interconnection of 4 Nos 63A outgoing Switches to bus bar. |
| 291 | A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 9 Nos 3 phase switches and supply & fixing of the following switches. |
| 292 | 1.200 A TPNswitch disconnector fuse units interior only with HRC fuses double break - 1No2. 125A TPNswitch disconnector fuse units interior only with HRC fuses double break - 6Nos3. 63A TPNswitch disconnector fuse units interior only with HRC fuses double break - 6Nos |
| 293 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications.The earth bus with two runs of 1\" x 1/8\" tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted withtwo high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3\"x1½\"x½\" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (Boys & Girls Hostel panel) |
| 294 | Supply and laying of 2 x 16 sq.mm PVC aluminium armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering three sides of the cable completely with bricks and sand and refilling the earth to make good. |
| 295 | Supply and clamping of 2 x 16 sq.mm. PVC aluminium LTUG armoured cable on post or on wall with MS clamps. |
| 296 | Supply and fixing of brass cable gland for 2x16 sq.mm PVC aluminium LTUG armoured cable with earth connection. |
| 297 | Supply and laying of 4 x 16 sq.mm PVC aluminium armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering three sides of the cable completely with bricks and sand and refilling the earth to make good. |
| 298 | Supply and clamping of 4 x 16 sq.mm. PVC aluminium LTUG armoured cable on post or on wall with MS clamps. |
| 299 | Supply and clamping of 3-1/2 x 35sq.mm. PVC aluminium LTUG armoured cable on post or on wall with MS clamps. (for 63A Switch) |
| 300 | Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC aluminium armoured LTUG cable with earth connection. (for 63A Switch) |
| 301 | Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC aluminium LTUGarmoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.(for 63A Switch) |
| 302 | Supply and laying of 3-1/2 x 50 sq.mm. PVC aluminium LTUG armouredcable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering three sides of the cable completely with bricks and sand and refilling the earth to make good.(for 63A Switch) |
| 303 | Supply and clamping of 3-1/2 x 50sq.mm. PVC aluminium LTUG armoured cable on post or on wall with MS clamps. (for 63A Switch) |
| 304 | Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC aluminium armoured LTUG cable with earth connection. (for 63A Switch) |
| 305 | Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC aluminium LTUGarmoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.(for 63A Switch) |
| 306 | Supply and clamping of 3-1/2 x 70sq.mm. PVC aluminium LTUG armoured cable on post or on wall with MS clamps. (for 63A Switch) |
| 307 | Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC aluminium armoured LTUG cable with earth connection. (for 63A Switch) |
| 308 | Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC aluminium LTUGarmoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.(for 63A Switch) |
| 309 | Supply and laying of 3 1/2 x 185 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering three sides of the cable completely with bricks and sand and refilling the earth to make good. |
| 310 | Supply and clamping of 3 1/2 x 185 sq.mm PVC aluminium armoured LTUG cable on post or on wall with MS Clamps. (For LTCT Service and main switch) |
| 311 | Supply and laying of 2 Runs 3 1/2 x 185 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering three sides of the cable completely with bricks and sand and refilling the earth to make good. |
| 312 | Supply and clamping of 2 Runs 3 1/2 x 185sq.mm PVC aluminium armoured LTUG cable on post or on wall with MS Clamps. |
| 313 | Supply and fixing of brass cable gland for 3 1/2 x 185 sqmm PVC aluminium armoured LTUG cable with earth connection. |
| 314 | Supply and providing cable end termination of 3 1/2 x 185 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.(SD-242) |
| 315 | Supply and clamping of 3 1/2 x 240 sq.mm PVC aluminium armoured LTUG cable on post or on wall with MS Clamps. (For LTCT Service and main switch) (SD-230) |
| 316 | Supply and fixing of brass cable gland for 3 1/2 x 240 sqmm PVC aluminium armoured LTUG cable with earth connection.(SD-194) |
| 317 | Supply and providing cable end termination of 3 1/2 x 240 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.(DATA-29) |
| 318 | Supply and fixing of 200 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. |
| 319 | Earthing as per the ISI specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 320 | Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work. |
| 321 | Supply and run of No-8 SWG Copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. |
| 322 | Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. |
| 323 | Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. |
| 324 | Supply erection, testing and commissioning of 1.5 TR (4500 K.cal/Hr) ABS Plastic Split type Inverter Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with inverter compressor operating on refrigerant of non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with5 star rating as per BEE specification and capable of performing the functions |
| 325 | 1) Cooling |
| 326 | 2) Dehumidifying |
| 327 | 3) Air circulating |
| 328 | 4) Filtering |
| 329 | The installation work for the above split type AC units inculds the following |
| 330 | 1.Mounting /fitting indoor and outdoor units at their respective locations. |
| 331 | 2.Laying copper refrigerant pipeof 0.8mm thick of required length connection not exceeding 4 meters distance and both units after drilling hole/holes in the wall ifrequired. |
| 332 | 3.Insulating the suction pipe with expanded polyethylene foam 5mm tubing. |
| 333 | 4.Laying 20mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. |
| 334 | 5.Leakage testing the entire system gas in the unit. |
| 335 | 6.Charging refrigerant gas in the unit. |
| 336 | 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit.(Carrier / Bluestar / O-General / Daikin make) |
| 337 | Supply and installation of 4 kVA Electronic Automatic Voltage Stabilizer V- GUARD makeVND 500 Model with Input Voltage range of150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 338 | Supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Inverter Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with inverter compressor operating on refrigerant of non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with5 star rating as per BEE specification and capable of performing the functions |
| 339 | 1) Cooling |
| 340 | 2) Dehumidifying |
| 341 | 3) Air circulating |
| 342 | 4) Filtering |
| 343 | The installation work for the above split type AC units inculds the following |
| 344 | 1.Mounting /fitting indoor and outdoor units at their respective locations. |
| 345 | 2.Laying copper refrigerant pipeof 0.8mm thick of required length connection not exceeding 4 meters distance and both units after drilling hole/holes in the wall ifrequired. |
| 346 | 3.Insulating the suction pipe with expanded polyethylene foam 5mm tubing. |
| 347 | 4.Laying 20mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. |
| 348 | 5.Leakage testing the entire system gas in the unit. |
| 349 | 6.Charging refrigerant gas in the unit. |
| 350 | 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit.(Carrier / Bluestar / O-General / Daikin make) |
| 351 | Supply and installation of 5 kVA Electronic Automatic Voltage Stabilizer V- GUARD makeVND 500 Model with Input Voltage range of150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 352 | Supply and laying of 5/8\" and 3/8\" soft drawn copper refrigerant pipe of 0.8mm thick by flaring connection with interconnection wire between indoor & outdoor unit and 20mm drain pipe.(Extra beyond 3 mts/AC unit) |
| 353 | Supply and fixing of MS stand for fixing the outdoor unit |
| 354 | Supply and fixing of water drain pipe line (1\" PVC pipe) |
| 355 | Supply, Installation, testing and commissioning of ducted type 17 TR Floor Mounted Package type airconditioning units with indoor unit comprising scroll type compressor, cooling coil,evaporator fan and motor controls, insulated drain pan enclosed in sheet metal cabinet and 2 Nos of 8.5Tr outdoor unit completed with condenser fan and motor and enclosed in powder coated sheet metal cabinet Unit shall be suitable for operation on 415 +/-10% Volts,50 HZ, AC Supply, units shall be supplied withmicroprocessor control panel. |
| 356 | Price shall be inclusive of all power wiring from microprocessor panel to package unit and power & control wiring between package unit and out door units..Carrier make with condenser fan and motor and enclosed in powder coated sheet metal cabinet Unit shall be suitable for operation on 415 +/-10% Volts,50 HZ, AC Supply, units shall be supplied with microprocessor control panel. Price shall be inclusive of al l power wiring from microprocessor panel to package unit and power & control wiring between package unit and out door units.(Carrier make) (Computer Lab,Conference room,Moot court hall,Video conference) |
| 357 | Supply, Installation, testing and commissioning of 8.5TR Ceiling supsended Ducted type airconditioning units with indoor unit cooling coil, evaporator fan and motor controls, insulated drain pan enclosed in sheet metal cabinet and 1 No of 8.5Tr outdoor unit comprising scroll type compressor, complete with condenser fan and motor and enclosed in powder coated sheet metal cabinet Unit shall be suitable for operation on 415 +/- 10% Volts,50 HZ, AC Supply, units shall be supplied with microprocessor control panel. Price shall be inclusive of all power wiring from microprocessor panel to package unit and power & control wiring between package unit and out door units. (Carrier make) |
| 358 | Supply, fabrication and fixing of MS channel for mounting the Airconditioning Indoor Unit. |
| 359 | Supply, fabrication and fixing of MS channel for mounting the Airconditioning Outdoor Unit. |
| 360 | Supply and filling of R410A Refrigerant Gas |
| 361 | Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 20 Gauge thickness. |
| 362 | Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 22 Gauge thickness. |
| 363 | Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 24 Gauge thickness. |
| 364 | Supply and providing Acoustic for initial portion of Ducting with 12mm thick fiber glass rigid board covered with Tissue Paper and Aluminium Perforated Sheet. |
| 365 | Supply and fixing of extruded Aluminium powder Coated, supply and return Air Grilles /Diffusers with volume control dampers. |
| 366 | Supply and fixing of flexible Canvas connection |
| 367 | Supply and providing thermal insulation of 9 mm thick vidoflex with Aluminium Foil. |
| 368 | Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of 28.6mm |
| 369 | Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of15.90mm size |
| 370 | Supply and providing of pipeline nitral rubber insulation for section line refrigerant pipe and PVC pipe |
| 371 | Supply of extruded aluminium powder coated Gravity Louvers |
| 372 | Supply and providing 3core of 2.5sqmm copper flexible cable |
| 373 | Units Lifting, shifting, positioning charges |
| 374 | 62.5KVA Genset:Supply, Erection, Testing, Commissioning and Handing over of 1 No 62.5 KVA Diesel Generator set of 0.8P.f, Three Phase, 415/440Volts, 50c/s, 1500RPM as detailed belowENGINE: Air cooled Diesel engine suitable for generator application with a shaft Output of 83 BHP at 1500 RPM under NTP Condition as per BSS 5514/IS 10000. The engine shall comprise the following standard scope of supply: (Make Kirloskar green / Cummins / Ashok Leyland) 1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator fan and mounting 4. Air to air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter(pre and micro) 8. In-line Mono-block fuel injection pump with governor and fuel feed pump 9. Electronic governor 10. 24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test Certificate 13. Residential Mufler 14. Fly wheel with starter ring. |
| 375 | 1. ENGINE INSTRUMENT PANEL MOUNTED. Engine control panel consisting of ON/OFF/START Key Lube oil pressure guage , oil temperature gauge, high water temperature guage and electronic hour meter and RPM indicator 2. SAFETY SYSTEM OF ENGINE :-The Engine shall trip for the following conditions with visual alarm device 1. Low lubricating oil pressure 2. High Water temperature 3. Vee-belt failure and over speed 4. The visual indicator should be provide for Low battery indication.The engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load. |
| 376 | 3. ALTERNATOR : Alternator capacity of 62.5 KVA/50 KW,AC 3 phase, 50HZ, 415/420V, 0.8PF with brushless excitation, self regulated designed to run at 1500 RPM under NTP conditions confirming to BS 5000/ IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate (Make: Kirloskar/ Stamford) |
| 377 | 4.ACOUSTIC ENCLOSURE:- Acoustic enclosure shall be powder coated and fabricated of 16 SWG CRCA MS sheet.The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machine to maintain dimensional accuracy of hole within 0.1mm Powder coating done after seven – tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64 Kg/m density mineral wool of 100mm thickness as Acoustic material. Four hinged doors shall be provided to canopy.The maximum permissible sound pressure level for new diesel generator (DG) sets shall be 75 dB(A) at 1 metre from the enclosure surface, as per CPCB norms. Surface treatment – Painting: The enclosure surface shall be suitably treated for degreasing de-rusting and posphating. The canopies are passed through seven – tank treatment thoroughly. Additional features of canopies: Canopy fabricated on CNC machines with dimensional accuracy of 0.1 mm so as to increase its durability. |
| 378 | Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any World class Cooling package: Canopies shall have cooling package for which it can also perform at 45 degree C/ambient temperature. No grouting required on the ground, only a level surface capable of with standing the DG weight.Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set.The Gen set frame shall also be provided with hooks for unloading Temperature rise inside the canopy: Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well within 5-7 deg centigrade. |
| 379 | 5. FUEL TANK : 150 liters. Removable fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connection and mechanical fuel gauge. Fuel tank can be easily removed for clearing or any maintenance.6. BASE FRAME : The base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall be have provision for mounting of acoustic enclosure on it. The supply of generator set includes loading. Unloading and transportation charges.7. Battery: 1 No 12V 150AH Battery.8. Valid Type Approval Certificate and Conformity of Production certificate from the Authorised agencies should be produced to the department officials. |
| 380 | Supply, erection, testing, Commissioning and Handingover of 250 kVA Diesel Generator set of 0.8 P.F, three phase 415V/ 420 Volts, 50Hz, 1500 RPM CPCB Approved capacity with 310 HP Engine Rated output ofwater cooled clock wise rotating feed pump with 200kW/ 250kVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges. |
| 381 | (A) Engine: Water cooled diesel engine suitable for Generator application with a engine rated output of 310 HP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, air cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc.(Kirloskar Green / Cummins / Ashok Leyland make) |
| 382 | (B) 12/24 Volt Electronic starting Equipment:Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length |
| 383 | (C) Engine Instrument Panel / Mounted:Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge,water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load. |
| 384 | D)ALTERNATOR: 250kVA/200kW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to IS:13364 (Part-II)/ 1992 to be means of coupling. (Stamford make/ Eq) |
| 385 | (E) AMF CONTROL PANEL:The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connection incoming and outgoing leads having been made on the control panel. |
| 386 | 1. AC Ammeter and selector switch |
| 387 | 2 .Volmeter and selector switch |
| 388 | 3. 3Nos current transformer with suitable ratio |
| 389 | 4. Frequency meter |
| 390 | 5. KWH meter |
| 391 | 6. 1 No power factor meter |
| 392 | 7. Battery charging set comprising of the following for charging the battery(2Nos 180AH) from mains |
| 393 | a. Transformer / Rectiferb. DC Ammeterc. DCVolt meterd. ON / OFF switche. Charging rate selector switchf. push button startg. push button stoph. push button reset |
| 394 | 8. 1 set Air break contactor with auxiliary netural contactor for main supply |
| 395 | 9. 1 set Low volage HRC fuse for the short circuit protection of the main supply |
| 396 | 10. 1 set Alternator contactor with auxiliary netural contactor |
| 397 | 11. 1 set Three pole bimetal release for over load protection of alternator |
| 398 | 12. 1 set low voltage HRC fuse for the short circuit protection of the alternator |
| 399 | 13.1 set DC control relays incorporating engine start/ stop and failure to start / lockout |
| 400 | 14. 1 set selector switch auto/ manual |
| 401 | 15. 1 no Push button \"Start\" |
| 402 | 16. 1 no Push button \"Stop\" |
| 403 | 17. 1 no Push button \"Reset\" |
| 404 | 18.1 No signal lamp for indicating load on mains |
| 405 | 19. 1 no signal lamp for indicating load on set |
| 406 | 20.1no signal lamp for indicating set fails to start |
| 407 | 21.1no signal lamp for indicating set running |
| 408 | 22.1No signal lamp for indicating battery |
| 409 | 23. 1set Pilot lamps of 3 nos |
| 410 | 24. MCCB of 250A capacity with magnetic thermal overload release, instant start circuit trip and under voltage release switch |
| 411 | 25.Rectangular copper bus bars (1No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with head shrinkable PVC sleeves. |
| 412 | 26.1No mains voltage monitor |
| 413 | 27.Hooter/Audio alarm for indicating set fails to start and for DG O/L. |
| 414 | 28.1set Timers |
| 415 | 29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressureb) High water temperaturec) Over speed |
| 416 | 30.1No Earth fault relay |
| 417 | 31.Isolator to isolate the neutral |
| 418 | 1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements.2. The engine should trip for the following: a) Low lubricating oil pressureb) High water temperature c) Over speed |
| 419 | 3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service wih 200 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. |
| 420 | F.FUEL TANK460 litres fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame.It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance. |
| 421 | G.BASE FRAME:Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment. |
| 422 | H) ACOUSTIC ENCLOSURE:The Acoustic enclosure,Self standing weather proof KG- CPCB Typed Acoustic canopy KG 125WS floor mounting type with modular construction with the provision to assemble and dismantle easilyanddesigned to suit all weather condtions. Erection of acoustic enclosure suitable for 125KVA Diesel generator complete with all accessories as above and suitable supports etc. |
| 423 | Outer body 2 mm CRCA sheet steel door 2mm thick CRCA sheet. Inner surface 0.8m thick GI perforated sheet. Perforation area should be 2/3 of total area. |
| 424 | Insulation : 100 mm thick rock wool / (Density 65 Kg / cub.m) or as approved by competent authority to suit CPCB norms. The maximum permissible sound pressure level for diesel generator (DG) set shall be 75 dB(A) at 1 metre from the enclosure surface. |
| 425 | Supply of manuals for operation & maintenance of DG set with warranty card etc.CEIG approval: Preparation of site plan physical layout, electrical line schematic Diagram 10 sets, getting drawingapproval from CEIG preparationofcomplection report rectificationreport etc., arrangingCEIG inspection and obtainingCEIG safety certificate, payment of CEIG inspection fees if necessary and preparation of one set of approval Drawing and copy of safety certificate in a neat frame work. |
| 426 | (L)TESTING AND COMMISSIONING |
| 427 | After the installation of DG set on its foundation, the DG set should be tested and commissioned with first charging of lubrication oil to its level, first charging of battery and run the set for eight hours on full load test complete.The Genset engine and alternator make should be approved by SE before used on work. (SR) |
| 428 | ERECTIONOF GENSET: Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation and erection of generator set with proper alignment over the existing foundation. |
| 429 | Supply and erection ofTransformer plinth with suitable foundation for 500kVA outdoor transformer of size length 1.5m x breadth 1.5m x height 2.0m in the brick work, concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation for proper alignment of transformer equipment. |
| 430 | Supply and erection of 22KV 2 pole structure comprising 2 numbers 33’feet with RS Joist of size 200x100x5.7mm centre to centre 10 feet width with tie and support frame by 100x50x6mm RS channels, cross bracings by 50x6mm RS angles with requisite heavy duty clamps, bolts & nuts to support the switch gears,insulators, 0 copper jumpers and accessories to receive and distribute the 22 KV 2Pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat each as per engineer in charge with supply and erection of following HT accessories as per I.E rules and CEIG rules and regulations |
| 431 | a) 1sets 22 KV gang operated double break AB switch complete with connecting rod, operating handle, guides, ets., on 100x50 mmchannel frame. |
| 432 | b) 3 Nos lightning arrestor for 22KV system on channel frame |
| 433 | c) 1 set (each with 3Nos)DO/HG fuse assembly on channel frame. |
| 434 | d) 6 Nos Sufficient number 22KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rules. |
| 435 | e) 1Set of 3Nos 22KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. |
| 436 | Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors “O” HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding. |
| 437 | Supply, erection, testing and commissioning of 22kV/433V, 500KVA outdoor type oil immersed Distribution Transformer ofDyn11 vector group, ONAN cooling,copper wound with energy efficieny of Level 2withoff circuit with a tapping range of +5% to -5% in 5 steps with standard fittings and accessories (as per IS 1180-Part 1 with Amendment 1 to 4 ) and fitted with the following: a) HV Bushing Terminal arrangements.b) LT cable end box suitable for connection 3 run of 31/2 x 400 sqmm LTUG cables. c) Conservator with shutt of valve. d) Dehydrating slilicagel breather. |
| 438 | e) Conservator drain plug valve. f) Tank drain plug value. g) 4 Nos Plain rollers. h)Thermometer pocket with thermomoter with capillary tubing for maximum reading position. i) Drain plug valve. j) Filter valve. k) Oil filling whole end cap. l) Oil level guage. m) Two body earthing terminal. n)Rating and terminal marking diagram plate. |
| 439 | o) Lifting hooks / Lifting eyes / Jacking pad to facilitate movement to transformer and easy ground level. p) Off load hand operated tap changing switch at standby height from ground level. q) Tapping on primary winding for voltage variation +5% to - 5% in 5 steps r) Neutral on L.V side to be available for 4 wire supply and brought out truf pushing for earthing.s) Air release device. t) The transformer should be supplied with first filling of oil. u) Maximum Total losses for 22kV class transformer at 50% load is 1502 W and at 100% load is 4305 W.v) %Impedance = 4.50 |
| 440 | w) 100 / 5 A ratio Tape Insulated Ring Type \"BPL\" Low Tension Current Transformer (AE make / Eq) with Rated Burden of 15 VA , Accuracy Class of5P10 in suitable Metallic enclosure fortransformer neutral - earth link terminal with necessary connections complete. (Make:ROWSONS / Kirloskar electric company). |
| 441 | Supply and providing HT yard link fencing with fixing of 8ft height in RCC concreted pillar of size 0.7f x 0.75ft by excavated the earth with depth of 2ft putting concrete pillar and refilling the earth to make good and fixing of chain link fencing with size of (2\"x2\")x10SWG galvanised iron wire all around the HT yard with necessary binding wire with ISI earthing. RCC pillar with chain link fencing should be provided for the total area of 48x20ft for seperate the EB yard and consumer supply yard places. |
| 442 | HT yard is provided with two gate entries, where one entry for EB side and another entry for consumer side. Each gate is fabricated using 2\" GI pipe as outer frame with weldmesh with necessary support. Earthing the fencing by using no.8 SWG copper wire all around the fencing. Earthing of gate by using 25mmx3mm copper flat, filling the yard with 400mm jelly for a height of 0.50feet from groundlevel to make good. |
| 443 | Design manufacturing Supply, erection, testing, commissioning and handing over of 22kV 25kA HT outdoor Three panel vacuum Circuit Breakers Switch Board VCB Comprising one number 630A 18.4 KA VCB as incoming and 2 Nos 630A 18.4 KA VCB as outgoing panels for outdoor installation each panel comprising 1. Draw out type 22 KV 630A 18.4 KA Horizontal Draw out / Horizontal isolation Vacuum Circuit Breaker with Motor (230V AC. – AC source of supply to be arranged purchaser) operated spring charged mechanism. |
| 444 | Anti Pumping Device 110V DC shunt trip and closing coils (DC source of supply to be derived from 3 Power Pack suitable for 3 tripping and two closing operation counter, 4 no + 4 NC spare Aux, contact for customer use, automatic safety shutter, mechanical close / trip knob, mechanical on/off indication, operating hand, 110V AC – 110V DC Power Pack etc (Incoming 1 No. 630A Outgoing 2 Nos of 630A). |
| 445 | 2. 22KV / Root 3 / 110V /Root3 – Three phase, 3 Limb 200VA Class 1 Resin Cast Draw Out type Potential transformers complete with HT and LT HRC Fuses (Incoming – 1 No.)3. Current Transformers of 100 – 50/5-5 Amps. Dual Core (Core 1 -15 VA class 1 for metering and core 2-15 VA 5P 10 for protection) for incoming 3 Nos, current transformers of 30/5-5 Amps dual core |
| 446 | (Core 1-15VA Class 1 for metering and core 2 – 15VA 5P 10 for protection) for outgoing 2 Nos. |
| 447 | 4. Meters :Digital Ammeter with Selector Switch (Incoming 1 No. Outgoing 1 No.)Digital Voltmeter with Selector Switch (Incoming 1 No.) |
| 448 | Digital Trivectormade of L&T / Secure make (Incoming 1 No) |
| 449 | Digital power factor meter – 1 No. |
| 450 | Digital Frequency Meter (Incoming 1 No.) |
| 451 | 5. Protection : |
| 452 | TP ND IDMT 2 OC + 1 EF Relay with highest Instt elements similar like mega with type MCDG 61. (Incoming 1 No.) |
| 453 | 6. TP ND IDMT 2 OC + 1 EF Relay similar like Megawin type MCDG 31 Master trip replay Megawin MVAJH 13 (Incoming 1 no. Outgoing 1 no.) |
| 454 | 7. Breaker ON/OFF Auto trip / Healthy trip / Spring charged indication (Incoming 5 Nos. Outgoing 5 Nos.) |
| 455 | 8. Phase indicating Lamps RY and B (Incoming 3 Nos.) |
| 456 | 9. Control wiring |
| 457 | 10.630A Copper Bus Bar PVC sleeved and required panel copper earthing. |
| 458 | 11. Control Switch TNC (Incoming 1 no. Outgoing 1 No.). |
| 459 | 12. Trip Circuit Healthy Push Button (Incoming 1 No. Outgoing 1 No.). |
| 460 | 13. Common for Switch gear, MCB’s for AC DC Control Heater ON / OFF Switch with space heater and thermostat single phase switch socket, cubicle illumination lamp, Disconnecting type terminal Block etc. 14. MS sheet enclosure for Indoor Installation Powder Coated with paint shade Siemens Grey. Provision through Bottom entry to receive Incoming or outgoing cable excluding cable glands and cable terminal kit. (Make : System control /Mega win / Pentagon/ Equivalent) |
| 461 | Supply and clamping of 1R x 3C x 240 sq.mm HT XLPE 22 kV (E) aluminium armoured cable (Polycab/Eq)in Existingtrench or on wall with MS Clamps. |
| 462 | Supply and laying of 1R x 3C x 240 sq.mm HT XLPE 22 kV (E) (Polycab/Eq)aluminium armoured cable in a trench to be excavated at a depth of 1m putting 0.15m layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. |
| 463 | Supply and providing of HT cable outdoor termination for 3 core 240 sqmm 22kV (UE) belted PILC cable with necessary connection complete. (Rechym RPG/Eq) |
| 464 | Supply and laying of 3Runs of 3½ X 400 sq.mm PVC aluminium armoured LTUG Cable in a trench to be excavated at a depth of 0.75m putting 0.15m layer of sand and covering the cable completely with bricks and and refilling the earth to make good. |
| 465 | Supply and clamping of 3R X3 ½ x 400 sq.mm PVC LTUG aluminium armoured LTUG cable in existingtrench or on wall with MS Clamps. |
| 466 | Supply and fixing of brass cable gland for 3½ x 400 sqmm PVC armoured LTUG cable with earth connection. |
| 467 | Supply and providing cable end termination of 3½ x 400 sqmm PVC Aluminium armouredLTUG cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. |
| 468 | Supply of 100KVAR 415/440 volts 3 phase Automatic Power Factor at 0.95 lag made up of powder coated 18 SWG CRCA sheet steel enclosure with 250A TP MCCB as incoming (Siemens / C & S) with Delta connected capacitors (BCH / EPCOS) MPP type operating in multiple stage with 3 current and voltage Transducers (CVT) at the phases simutataneously to activate the desired power factor with a LCD display to show the following parametrers. |
| 469 | A) Vr-R phase Line VoltateB) Vy-Y phase Line VoltateC) Vb-B phase Line VoltateD) Ir-R phase Line currentE) Iy-Y phase Line currentF) Ib-B phase Line currentG) KW -present Kilo WattsH) KVAR- present KVAR DemandI) KVA -present KVAJ) PF- present power factorK) Number of capacitor bank ON/OFFL) Provision to indicate the unbalanced load provision to indicate the change in phase sequence. |
| 470 | The APFC panel should also with built in protection for high voltage/low voltage cut off, single phase preventor in current line surges, current limitors, current sensor etc., with connection complete and as per the relevant rules. Eight stages of Automatic power factor control panel with necessary connection.Stage wise details: I) Stage : 25 KV AR II) Stage : 20 KV ARIII) Stage : 15 KV ARIV) Stage : 10 KV ARV) Stage : 10 KV AR VI) Stage : 10 KV ARVII) Stage : 5 KV ARVIII) Stage : 5 KV AR |
| 471 | Preparation of Site plan, physical layout electrical schematic diagram(6 Sets) getting drawing approval from CEIG, preparation of completion report rectification report etc. arranging CEIG inspection, paying CEIGinspection fees and obtaining safety certificate from CEIG. |
| 472 | Lift arrangements:Supply, erection, testing, commissioning and handing over of 1 No 10 persons capacitygearless passenger Lift with machine room as per IS 14665 with latest amendments with the following Technical specifications |
| 473 | Location : Admin block |
| 474 | 1. Type of lift : PassengerLift |
| 475 | 2. Capacity of lift : 10 persons capacity passenger lift(680 Kgs) |
| 476 | 3. Speed : 1 Metre / Sec |
| 477 | 4. Type of Drive: Microprocessor based V3F drive permanent Magnet Synchronous Motor Gearless machine with two independent Dynamic braking |
| 478 | 5. No. offloors: Ground +2 floor |
| 479 | 6. Total Travel:7.2metres |
| 480 | 7. Levelling Accuracy: High level accuracy with smooth and jerk free stopping. |
| 481 | 8. Construction of Car:SS 304 grade 18SWG High quality stainless steel car with Neat hair line finish vinyl flooring and false ceiling. |
| 482 | 9. Position of machine: Directly above the lift shaft. |
| 483 | 10. No. of landing entrance: 3Nos |
| 484 | 11. No. of car entrance:one in front only |
| 485 | 12.Car entrance door: Power operated V3F drive Telescopic door opening sliding stainless steel scratch proof door with hair line finish. |
| 486 | 13. Landing entrance door:SS 304 grade center door opening with hair line finish with provision for emergency key opening at all landings. |
| 487 | 14.Lift well existing: 2100mm (width)x 2100mm (depth) |
| 488 | 15. Lift pit depth:1500mm |
| 489 | 16.Car size: 1300mm (width) x 1350mm (Depth) |
| 490 | 17. Entrance: 800 mm (width) x 2000mm (height) |
| 491 | 18.Lift machine room : 4350mm width x 5500mm (depth) |
| 492 | 19. Power supply: 400/440 V, 3 phase, 50 Cycles/sec A.C. supply for power and 230 V, 50 HZ, single phase, AC supply for light. |
| 493 | 20. Control: Micro Processor basedsimplex selective collective control with/without attendant. |
| 494 | 21.Car fittings: sleek LED light fitting with 300mm sweep cabin fan |
| 495 | 22.Lift well: R.C.C. construction with brick masonry. |
| 496 | 23.Indication: Indication: UP/Down digital direction and position indicator for all landing and in car (25mm Height, seven segment Digital Floor position indicator scrolling type) |
| 497 | 24.Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device |
| 498 | 25.Emergency light: Battery operated light to be provided with Automatic charging device. |
| 499 | 26.Fire Man’s switch: To be provided at ground floor |
| 500 | 27.Minor builders work: included in the scope. |
| 501 | 28.Scaffolding: Included in the scope |
| 502 | 29.Sill angles and facia plates: included in the scope. |
| 503 | 30.Steel for lift machinery: Included in the scope. |
| 504 | 31.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. |
| 505 | 32.Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. |
| 506 | 33. To be provided by the lift contractor with in-built intercom ( push type) in car panel and with provision of push type intercom in machine room and ground floor entrance. |
| 507 | 34. Floor annunciator with music with announcement in both Tamil and English. |
| 508 | 35.Special features: |
| 509 | a. Infra-red door sensor with full height screen |
| 510 | b. Voltage stabilizer for circuit control. |
| 511 | c. Stainless Steel signal fixtures. |
| 512 | d. Vandal proofS.S. Button with S.S. cover |
| 513 | e. SS door frames for landing doors. |
| 514 | f. VF door operator. |
| 515 | g. Call Register signal |
| 516 | h. Stainless steel facia plate for car operating panel and landing fixtures. |
| 517 | i. On – Off switch for fan and light |
| 518 | j. Over load warning indicator with audio announcement |
| 519 | 36.Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity,electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. |
| 520 | 37.Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period of not less than one year. |
| 521 | 38.Site testing in accordance with IS 14665 should be carried out at thetime of handing over.39. Supply of operation and maintenance manual with necessary tools for operation.40. Lift licence : Preparation of drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. (Johnson / Kone/ OTIS make) (SR) |
| 522 | Lift arrangements:Supply, erection, testing, commissioning and handing over of 1 No 20 persons capacitygearless passenger Lift with machine room as per IS 14665 with latest amendments with the following Technical specifications |
| 523 | Location : Admin block |
| 524 | 1. Type of lift : PassengerLift |
| 525 | 2. Capacity of lift : 20 persons capacity passenger lift(1360 Kgs) |
| 526 | 3. Speed : 1 Metre / Sec |
| 527 | 4. Type of Drive: Microprocessor based V3F drive permanent Magnet Synchronous Motor Gearless machine with two independent Dynamic braking |
| 528 | 5. No. offloors: Ground +2 floor |
| 529 | 6. Total Travel:7.2metres |
| 530 | 7. Levelling Accuracy: High level accuracy with smooth and jerk free stopping. |
| 531 | 8. Construction of Car:SS 304 grade 18SWG High quality stainless steel car with Neat hair line finish vinyl flooring and false ceiling. |
| 532 | 9. Position of machine: Directly above the lift shaft. |
| 533 | 10. No. of landing entrance: 3Nos |
| 534 | 11. No. of car entrance:one in front only |
| 535 | 12.Car entrance door: Power operated V3F drive Telescopic door opening sliding stainless steel scratch proof door with hair line finish. |
| 536 | 13. Landing entrance door:SS 304 grade center door opening with hair line finish with provision for emergency key opening at all landings. |
| 537 | 14.Lift well existing: 2700mm (width)x 2400mm (depth) |
| 538 | 15. Lift pit depth:1500mm |
| 539 | 16.Car size: 2000mm (width) x 1500mm (Depth) |
| 540 | 17. Entrance: 1000 mm (width) x 2000mm (height) |
| 541 | 18.Lift machine room : 4350mm width x 5500mm (depth) |
| 542 | 19. Power supply: 400/440 V, 3 phase, 50 Cycles/sec A.C. supply for power and 230 V, 50 HZ, single phase, AC supply for light. |
| 543 | 20. Control: Micro Processor basedsimplex selective collective control with/without attendant. |
| 544 | 21.Car fittings: sleek LED light fitting with 300mm sweep cabin fan |
| 545 | 22.Lift well: R.C.C. construction with brick masonry. |
| 546 | 23.Indication: Indication: UP/Down digital direction and position indicator for all landing and in car (25mm Height, seven segment Digital Floor position indicator scrolling type) |
| 547 | 24.Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device |
| 548 | 25.Emergency light: Battery operated light to be provided with Automatic charging device. |
| 549 | 26.Fire Man’s switch: To be provided at ground floor |
| 550 | 27.Minor builders work: included in the scope. |
| 551 | 28.Scaffolding: Included in the scope |
| 552 | 29.Sill angles and facia plates: included in the scope. |
| 553 | 30.Steel for lift machinery: Included in the scope. |
| 554 | 31.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. |
| 555 | 32.Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. |
| 556 | 33. To be provided by the lift contractor with in-built intercom ( push type) in car panel and with provision of push type intercom in machine room and ground floor entrance. |
| 557 | 34. Floor annunciator with music with announcement in both Tamil and English. |
| 558 | 35.Special features: |
| 559 | a. Infra-red door sensor with full height screen |
| 560 | b. Voltage stabilizer for circuit control. |
| 561 | c. Stainless Steel signal fixtures. |
| 562 | d. Vandal proofS.S. Button with S.S. cover |
| 563 | e. SS door frames for landing doors. |
| 564 | f. VF door operator. |
| 565 | g. Call Register signal |
| 566 | h. Stainless steel facia plate for car operating panel and landing fixtures. |
| 567 | i. On – Off switch for fan and light |
| 568 | j. Over load warning indicator with audio announcement |
| 569 | 36.Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity,electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. |
| 570 | 37.Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period of not less than one year. |
| 571 | 38.Site testing in accordance with IS 14665 should be carried out at thetime of handing over.39. Supply of operation and maintenance manual with necessary tools for operation.40. Lift licence : Preparation of drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. (Johnson / Kone/ OTIS make) (SR) |
| 572 | Supply and clamping of 4 x 16 sq.mm PVC aluminium LTUG armoured cable in suitable dia Class B G.I pipe on post or on wall with MS Clamps.(for street light post) (DATA-) |
| 573 | supply and fixing of 65 mm dia. (2 -1/2\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour . |
| 574 | Supply and installation of 15W Wall Mount speaker with suitable wall mount bracket(Higher End). |
| 575 | Supply and installation of 30W Wall Mount speaker with suitable wall mount bracket (Higher End). |
| 576 | Supply and installationof 120WPower amplifierwhich consists of 5 channel microphone input, 2 aux, Built in MP3 Player with remote control for USB, tone and bass control, frequency response 50-15000Hz LED array, 0 - 70 - 100V line out put and impedance matching4/8/16 Ohms.(Higher End) |
| 577 | Supply and installationof 240W PA Mixer Amplifier (Higher End). |
| 578 | Supply and installationof 480W PA Booster Amplifier.(Higher End). |
| 579 | Supply and installation of Bosch LBB1956/00/ Eq Voice alarm Call station with following features- Stylish six-zone call station for the Plena Voice Alarm System, Six zone selection keys, all-call key and momentary PTT, key for calls, Selectable gain, speech filter, limiter, and output level for improved intelligibility, LED indications for zone selection, fault, and emergency state, Call station extension provides seven additional zone and zone group keys, Flexible microphone stem and unidirectional. |
| 580 | Supply and installation of Bosch LBB 1990/00/ Eq plena Voice Alarm Controller Compliant with standards for emergency soundsystems (IEC60849), with 6-zone system controller, Built-in 240 W booster amplifier, 12 Business and emergency control inputs and outputs. |
| 581 | Supply and run of 2 core 1.5sq.mm Shielded copper speaker wire in existing PVC rigid pipe concealed in wall and ceiling. (Higher End) |
| 582 | Supply and run of 2 of 2.5 sq.mm (36/0.3) PVC unsheathed copper conductor of 1100V grade with ISI mark in existing PVC rigid pipe. (Higher End) |
| 583 | Supply and run of 2 of 4 sq.mm (56/0.3) PVC unsheathed copper conductor of 1100V grade with ISI mark in existing PVC rigid pipe. (Higher End) |
| 584 | Supply and installation of Shure BETA 58A/ Senneihser Make Dynamic Vocal Microphone with high-Output supercardioid with suitable stand. |
| 585 | Supply and installation of Shure/ AKG/ Senneihser Make XLR Gooseneck Microphone with Base Powered through Phantom. |
| 586 | Supply and run of XLR Professional Microphone Cable in existing PVC rigid pipe concealed in wall and ceiling. (Higher end) |
| 587 | Supply and installation ofUHF Cordless Handheld / Tie Clip / Neck Band Microphone system.(Higher End) |
| 588 | Supply and installation of PA audio mixing consoles stereo which consists of 8 channel mic input Digital effects,Left & Right output controls stereo input, tone control for bass & treble and necessary connection. Make and Model :Sound Craft EPM8/ Studio Master. |
| 589 | Supply and installation of PA audio mixing consoles stereo16 channels mic input with following features; Inputs – Mic Preamps:16 x XLR• Inputs – Line:32 x TRS• Inputs – Other:1 x XLR (Talkback Mic), 1 x RCA, 4 x TRS (Stereo Input) • Outputs – Main:3 x XLR• Outputs – Direct:8 x TRS• Outputs – Other:6 x TRS (Aux), 2 x TRS (Monitor), 4 x TRS (Stereo Return)• Aux Sends:4 x Pre/Post, 2 x Post• Busses/Groups:4 x Bus• Channel Inserts:Yes• Headphones:1 x 1/4?• Talkback:Yes • EQ Bands:4-band Sweepable Hi-Mid/Lo-Mid. Make: Soundcraft LX7ii/ Eq |
| 590 | Supply and installation of 24 Channel Mixer with the following specificationsType: AnalogChannels: 28 (24 x Mono, 4 x Stereo)Faders: 33 x 100mmInputs – Mic Preamps: 24 x XLR (CH 1-24), 4 x XLR, 1/4? (Stereo Channels)Phantom Power: 28Inputs – Line: 24 x 1/4? (CH 1-24), 4 x 1/4? (Stereo Channels)Outputs – Main: 2 x XLR (Main), 1 x XLR (Center) |
| 591 | Outputs – Direct: 24 x 1/4? (CH 1-24)Outputs – Other: 2 x RCA (Rec/Alt), 2 x 1/4? (Rec/Alt), 4 x XLR (Group), 4 x 1/4? (MTX)EQ Bands: 4-band, Sweepable Hi-Mid, Low-Mid (CH 1-24), 4-band (Stereo Channels)Aux Sends: 4 x Pre, 4 x Pre/PostSend/Return I/O: 8 x 1/4? (Aux), 4 x 1/4? (Return)Busses/Groups: 4 x GroupsChannel Inserts: Yes (CH 1-24), 4 x 1/4? (Group), 2 x 1/4 (Main), 1 x 1/4? (Center)Talkback: Yes. Make:Soundcraft GB4-24/ Allen Heath. |
| 592 | Supply and installation of Studiomaster SVC1000/ Eq 1 kVA Voltage stabilizerSpecially designed for audio equipment. with Wide input voltage range for Indian conditions (180-250V), High overload capability,Short circuit protection., Less than 1 sec stabilization time, No waveform distortion, Low-noise operation, Accurate voltage control, Over and under voltage correction (automatically regulates in both conditions), Generator compatible, Voltmeter displays output voltage so no more \"drop\" during bass thump. |
| 593 | Supply and installation of 15kVA Single PhaseAutomatic Mainline Voltage Stabilizer With Bypass. Make: Pulstron/ Servo. |
| 594 | Supply and installation of JBL VRX932 LA/ British Acoustics MakeLine array speaker by hanging from ceiling with suitable array frame and heavy chain with features ; Power Rating 800 W / 1600 W / 3200 W,Frequency Range 57 Hz - 20 kHz (-10 dB), Dimensions (H x W x D) 343 mm x 597 mm x 376 mm (13.5 in x 23.5 in x 14.8 in) Frequency Response 75 Hz - 20 Hz (+/-3db) Coverage Pattern 100 x 15 nominal, Crossover Modes Bi-amp / passive, externally switchable Crossover Frequency 1.2 kHz, |
| 595 | System Maximum SPL, Passive: 130 dB SPL peak , Bi-amp LF: 130 dB SPL peak, System Sensitivity (1w @ 1m, Passive: 95 dB SPL, Bi-amp LF: 95 dB SPL, Bi-amp HF: 114 dB SPL, LF Driver 1 x JBL 2262H 305 mm (12 in) Differential Drive® woofer with, neodymium magnet, dual voice-coils, and dual magnetic gaps. HF Driver 3 x JBL 2408J, 38 mm (1.5 in) voice-coil, neodymium, compression driver, Nominal Impedance Passive: 8 ohm, Bi-amp LF: 8 ohm, Bi-amp HF: 8 ohm, Active Tunings, 18 mm, 11-ply birch plywood, Suspension / Mounting Finish Black DuraFlex™ finish, Grille, Power coated, black, 16-guage perforated steel with with acoustically transparent foam, Input Connectors |
| 596 | Supply and installation of JBL VRX918S/ British Acoustics Sub woofer with following features; Power Rating 800 W / 1600 W / 3200 W, Frequency Range 31 Hz – 220 Hz, Dimensions ((HH xx WW xx DD)) 508 mm x 597 mm x 749 mm (20.0 in x 23.5 in x 29.5 in), Frequency Response 34 Hz – 220 Hz, Recommended, Crossover Frequencies, 80 Hz, 24 dB / octave HPF, 80 Hz, 24 dB / octave LPF, Maximum SPL 130 dB SPL peak, System Sensitivity 95 dB SPL Including all connectors and accessories. |
| 597 | Supply and Installation of JBL PRX415M/ British Acoustics Make 15? Two-Way Stage Monitor and Loudspeaker System designed for main sound reinforcement / monitoring applications(Including Speak on Connectors) with following features : power rated peak 1200W, frequency range 55-19000 Hz. max SPL 128, Sensitivity 98 dB SPL 1W/1m, nominal impedance 8O. |
| 598 | Supply and Installation of Drive Rack 260/ Eq. Loudspeaker Management system(Including all XLR Connectors) with following features 2 channels, feedback elimination, RS 232 PC-GUI control 2.7s of alignment & zone delay, full band pass, cross over and routing configuration . |
| 599 | Supply and Installation of Crown XTi6002 Make/ British Acoustics Make Power Amplifier with following features; Channels 2, Sensitivity 1.4V, Rated Power Output (per channel) 3000W, 2O, 2100W 4O, 1200W 8O, Signal to Noise Ratio (below rated 1 kHz power at 8 ohms) 103 dB (A-weighted), THD < 0.5% Frequency Response (at 1W, 20 Hz - 20 kHz) + 0 dB, -1 dB, Crosstalk (below rated power) 20 Hz to 1 kHz >70 dB Dimensions 3.5\" x 19\" x 16.2\", Weight 24 lbs (10.9 kg), Shipping Weight 30 lbs (13.6 kg), IEC Power Connector 20A(Including all XLR Connectors from Mixer to Amplifier. |
| 600 | Supply and installation of MASS RACK/ Eq. Heavy duty 12U Rack, 550X450mm Rack with PDU 6 Socket, 10\" Tray(2 Nos), Cable Organiser 1U Closed, 2 Fan & Hardware Kit. |
| 601 | Supply and fixing of Honeywell/ APC/ Belkin Make 4 Socket 2 Meter Surge Protector |
| 602 | Supply, fixing, testing and commissioning of Uniq Digital UD86/ LG/ Samsung Make 4K 86 inches Interactive Displays (mounted on wall with suitable accessories) with following specifications; LCD Screen, 16:9 Aspect Ratio, 3840*2160 Resolution, D-LED Back Light Unit, 8ms Response time, 60Hz Refreshing Frequency, 1.07B(10bit) Display Colors, 350cd/sq.m Brightness with glass (typ), Contrast Ratio 1200:1, Viewing Angle 178deg., Life Time 30000 Hours, Infrared touch technology, Windows 7/8/10/P/Linux/Mac/Android System, 2 points writing and 20 points touch, finger/Passive pen/opaque objects Touch tool, minimum object size 3mm, |
| 603 | <10ms Response time, accuracy 2mm, Toughened Glass with level 7 of Mohs Standard surface Hardness, 3(Rear)+1(Front) HDMI IN, 1xHDMI Out, VGA IN, PC-Audio IN1, 3xUSB2.0, 3xUSB3.0, 2+1 USB Touch Output, RS232 x 1, LAN x 1, USB Type-C x 1, Light Sensor, Android 8.0 System Version, Dual core A73 + Dual core A53, Dual core Mali G51 GPU, 3GB RAM, 32GB ROM, PC SLOT Detachable Intel OPS module (80pin) Added/ WiFi SLOT(Detachable) and all relevant accessories such as Power Cord, USB Cable (Type-A, Type-B), HDMI Cable, Writing Pen, Remote Control.[BIS, CE, FCC Certifications must] |
| 604 | Supply and installation of 65 inches UHD Television with suitable wall mount stand and stabilizer. Make:LG 164 cm (65 inches) 4K Ultra HD Smart LED TV 65UR7500PSC/ Panasonic/ Samsung. |
| 605 | Supply, fixing, testing and commissioningof Samsung BET-H/ LG Make 55\" Class HDR 4K UHD Commercial LED TValong with suitable ceiling/Wall mount kit with following specifications; 16:9 Aspect Ratio, UHD, RF/DTV/AV IN, 2xUSB2.0, 3 x HDMI 2.0, Headphone/ SPDIF/ RJ-45 Connectors, H.265/ H.264/ H.263/ MPEG1/ MPEG2/ MPEG4 Video Format, 20W Audio Output Power, Dolby Audio, DNR, Micro Dimming, Internet Link, HDR10, Bluetooth Ver.4, Wifi Band 2.4GHz, Wifi Type 802.11a/b/g/n 2.4 G 2T2R, Built-in, CPU Cortex-A55 x 4, 1.1 GHz Processor, Android \"P\"-9.0 OS, 2.0GB DDR3 RAM, 125W Power Consumption.[BIS, CE, FCC Certifications must |
| 606 | Supply and installation of Samsung/ LG Make Make 32 inches HD television. |
| 607 | Supply and installation of NT/OREI/Neuvideo Make 1x8 4K HDMI Extender over Cat6 for 60 Meters. |
| 608 | Supply and installation of NT/OREI/Neuvideo Make 1x4 4K HDMI Extender over Cat6 for 60 Meters. |
| 609 | Supply and installation of SONY/ Benq/ Epson Make LCD Projector with 3600 Ansi Lumens, XGA(1024x768) Resolution and Contrast Ratio:20000:1. (Higher End) |
| 610 | Supply and fixing of8 feet x 6 feet Motorized Projector Screen of aspect ratio 4:3 format with all relevant accessories.(Higher End) |
| 611 | Supply and fixing of 3 Feet Ceiling Mount Kit for Projector (Higher End). |
| 612 | Supply and installation of 3 meter 4K HDMI Cable. |
| 613 | Supply and installation of 20 Metre HDMI Cable(Higher End). |
| 614 | Supply, installation, testing and commissioning of DLP Projector including standard lens with following specifications; 7500 Ansi Lumens Brightness, WUXGA (1920 x 1200), 2000000:1 Contrast Ratio, 16:10 Native Aspect Ratio, Laser Light Source with 30000 Hours Life, Input Connections(2x HDMI, 1xDVI-D, 1xVGA, 1xHDBaseT, 1x3D Sync), Output Connections (1 x VGA, 1 x 3D Sync, 1 x USB-A), Control(1xRS232, 1 Wired remote, 1 x mini USB), Power Consumption 299W(Min) & 618W(Max). Make: OPTOMA ZU750 or (Sony/ Panasonic/ Epson with same specification) |
| 615 | Supply, installation, testing and commissioning of Motorized projector screen of size 275 inches diagonalwith aspect ratio 16:10 and high gain. Make: Suvira or Liberty |
| 616 | Supply and installation of customized ceiling mount kit for projector by providing sufficient extension from ceiling to achieve maximum image size on 275\" Motorized Projector screen, run of 3 core 2.5 sq.mm Power cables for Projector and screen and Cat6 cables from Computer System/ Laptop to Projector and other relevant accessories. |
| 617 | Supply, installation, testing and commissioning charges of Sparsh/ Hik Vision/ Dahua Make 5MP Bullet CCTV Camera with following specifications; CMOS Image Sensor of size 0.37 inch, Day/Night Capable, 30 meter IR Range, 3.6mm Focal Length, triple compressed video streaming, 120 dB WDR, 60-70 SNR,H.265+/ H.264 Codec. compression technology, 1 to 1/100000 Electronic Shuttter speed, features such as white balance, auto gain control, back light compensation, remote administration, remote system update over network, PC Client, Web client, ONVIF Support, Static and Dynamic IP Support, IP 66 Housing, Certifications include FCC, CE and BIS. |
| 618 | Supply and installation of 8 Port PoE Switches for CCTV IP Camera with necessary connection(Higher End). |
| 619 | Supply and installation ofD-Link Make 16 Port PoE Switches for CCTV IP Camera with necessary connection. |
| 620 | Supply and installation of 24 Port PoE Switches for CCTV IP Camera with necessary connection(Higher End). |
| 621 | Supply and installation of 32 Channel 4K Network Video Recorder with 2 numbers of SATA ports with wireless mouse. Higher End |
| 622 | Supply and installation of64 Channel 4K Network Video Recorder with 8 numbers of SATA ports.Make:SNEOS NT-IN20880/ Hikvision /Dahua (including wireless mouse, 1.5 meter HDMI Cable). |
| 623 | Supply and fixing of 8TB Hard Disk for NVR with all relevant accessories(Higher End). |
| 624 | Supply and fixing of 65mm dia GI pipe (Class \"B\") of 10 meter length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom and with concreting on masonry pedestal with MS box 30cm x 20cm x 10cm with angle iron frame work with foor with lock and key arrangements. [ for fixing CCTV Camera]. |
| 625 | Supply, fixing and termination of RJ-45 I/O Socket for LAN with CAT 6 Module, Single Socket RJ-45 Face Plate and 2 Metre Length Patch Cord.(Higher End) |
| 626 | Supply, fixing and termination of 16 Port un-managed 10/ 100/ 1000 LAN Network switch in existing Rack with accessories (Higher End) |
| 627 | Supply, fixing and termination of24 Port Semi-managed 10/ 100/ 1000 LAN Network switch in existing Rack with accessories.(Higher End) |
| 628 | Supply, fixing and termination of 24 Port with Fiber port Fully-managed 10/ 100/ 1000 Layer -2 with 1G Uplink LAN Network switch with 4 numbers combo port for SFP in existing Rack with accessories. (Higher End) |
| 629 | Supply, fixing and termination of D-Link/ TP-Link/ Intellinet Make 16 Port CAT6 Patch Panel Fully Loaded. |
| 630 | Supply and fixing of Fully Loaded 24 Port Patch Panel fully loaded for Cat 6 Cable Management. (Higher End) |
| 631 | Supply and fixing of1 Meter Patch cord.(Higher End) |
| 632 | Supply and fixing of 6U Rack with accessories andfan with suitable angle iron frame work. (Higher End) |
| 633 | Supply and fixing of 36U Rack with accessories andfan with suitable angle iron frame work. (Higher End) |
| 634 | Supply and run of CAT-6 Unarmoured LAN Cable (Higher End) in existing PVC rigid pipe. |
| 635 | Supply and run of 6 core outdoor OFC cable (Higher End) in existing concealed PVC rigid pipe. |
| 636 | Supply, splicing and termination of Single Mode MediaConverter for Optical Fibre Cable. (Higher end) |
| 637 | Supply, installation, configuration and commissioning of NEOS Syntel/ Accord/ Matrix Make EPABX Base unit with 48 Analog Extensions and 4 Trunk Lines. |
| 638 | Supply and fixing of Beetel/ Panasonic Make Push Button Telephone with Caller ID. |
| 639 | Supply, fixing and termination of RJ-11 I/O Socket for Telephone with Single Socket RJ-11 Face Plate and CAT 6 PVC Module Box. (Higher End) |
| 640 | Supply, fixing and termination of Standard Make 20 pair MDF Box with module and Krone. |
| 641 | Supply, fixing and termination of Standard Make 100 pair MDF Box with module and Krone. |
| 642 | Supply and run of 20 pair unarmoured 0.5mm Telephone cable (Higher End) in suitable PVC rigid pipe Concealed in wall and ceiling and making good of the concealed portion with suitable colour. |
| 643 | Supply and run of 2 pair unarmoured 0.5mm Telephone cable (Higher End) in suitable PVC rigid pipe Concealed in wall and ceiling and making good of the concealed portion with suitable colour. |
| 644 | Supply and run of 3 core 1.5sq.mm PVC power cable of 1100V grade in existing concealed PVC rigid pipe. (Higher End) |
| 645 | Supply and run of 3 of 2.5sq.mm PVC insulated SC unsheathed Cu. Conductor in existing concealed PVC rigid pipe in wall and ceiling. |
| 646 | Supply and fixing of 5A/15A3 Pin combined flush type wall socket 15A flush type switch concealed in suitable MS box flush with wall with painting. |
| 647 | Supply and laying of 50mm/38mm HDPE Pipe in a trench excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 648 | Supply and fixing of 25mm PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour. DATA-26 |
| 649 | Supply and erection of 1 kVAonline UPS (Single Phase In & Single Phase Out) System with suitableSMF Battery arrangements with rack to provide minimum 2 hours back-up. |
| 650 | Supply and erection of 5 kVAonline UPS (Single Phase In & Single Phase Out) System with suitableSMF Battery arrangements with rack to provide minimum 2 hours back-up. |
| 651 | Supply and erection of 15 kVAonline UPS (three Phase In & Single Phase Out) System with suitableSMF Battery arrangements with rack to provide minimum 1 hours back-up. |
| 652 | Supply, fixing, testing and commissioning charges for eSSL UF-602/ Matrix Make Biometric Time Attendance Machine with Embedded Linux based, 800MHz Processor speed,1GB RAM, 8GB Internal Storage, LAN+Wifi 802.11b/g/n both Network Connectivity, Mifare Card Support, USB Port, Micro USB Port, Battery Backup, Internal Speakers, 20 Queue Throughput, STQC Certified Single Fingerprint Scanner, 24x 7 Operational Endurance, IP54 Ingress Protection. |
| 653 | GST 18 % |