| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 2 | Removing white or colour wash by scrapping and sand paperingandpreparing the surface smooth including necessary repairs to scratches etc. Complete |
| 3 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete |
| 4 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 5 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. Metres With cement mortar 1:4 (1 cement: 4 fine sand) |
| 6 | Demolishing brick work, manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres leadOf area 3 sq. metres and below |
| 8 | Providing and fixing pressed steel doorframes conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge Profile BFixing with adjustable lugs with split end tail to each jamb |
| 9 | Profile E Fixing with adjustable lugs with split end tail to each jamb |
| 10 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 11 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 12 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 13 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutter Second class teak wood |
| 14 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 15 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thickPowder coated minimum thickness 50 micron aluminium tubular handle bar. |
| 16 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 )transparent or dyedto required colour or shade, with necessary screws etc. complete |
| 17 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 18 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. compl300x16 mm |
| 19 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. compl250x16 mm |
| 20 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 21 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 22 | Dismantlingoldplasterorskirtingrakingoutjointsandcleaningthe surface for plasterincluding disposal of rubbish to thedumping ground within 50 metres lead. |
| 23 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge 1:3:6 or richer mix |
| 24 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge1:4:8 or leaner mix |
| 25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water tinnable priming coat with cement primer |
| 26 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 27 | Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade :Two or more coats on new work |
| 28 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :Using rough Kota stone |
| 29 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 31 | Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade |
| 32 | Providing and laying in situ seven course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymericmix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). |
| 33 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 12.21.1 In 75x75 mm deep chase |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and sh1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal sizeuttering - All work up to plinth level : |
| 35 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 36 | Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge. |
| 37 | Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 38 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 39 | Providing and laying in position specified grade of reinforced cement concrete1:1.5:3(1cement:1.5coarse sand: 3gradedstone aggregate 20 mm nominal size)up to plinth |
| 40 | Reinforcement cement concrete works in walls (any thickness)inckuding attached pilaster buttresses plinths and strings course, fillers, collumns, pillers, piers abutments, posts and struts etc. upto floor five levels excluding cost of shuttering shutterings, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 41 | Centering shuttering including struttings, ropping etc. and removal of form forFoundations, footings, bases for columns, etc. for mass concreate. |
| 42 | Centering shuttering including struttings, ropping etc. and removal of form forCentring and Shuttering for Suspended floors, roofs, landings, balconies and access platform |
| 43 | Centering shuttering including struttings, ropping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 44 | Centering shuttering including struttings, ropping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 45 | Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 46 | Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202.(IS 1786:2008 clause no. 1.6, Steel shall be procured from original/primary steel producers only and no re-rolled steel shall be used.) The following Primary Steel Producers have been approved for PWD, Uttarakhand vide Office Memorandum No. 65/10 adhi/praapti/12 Dated:25/01/2012 of the Chief Engineer, Level-1, PWD :1. SAIL (Steel Authority of India Ltd.)2. RINL (Rashtriya Ispaat Nigam Ltd.)3. Tata Steel4. Shyam Steel Industries Ltd. (Reinforcement for R.C.C. Work Using Thermo-Mechanically Treated Bars) |
| 47 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in 1:6 (1 cement : 6 coarse sand) |
| 48 | Half brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 49 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in 1:4 (1 cement : 4 coarse sand) |
| 50 | Cement plaster of mix 1:6 (1 cement : 6 fine sand)12 mm cement plaster on fair side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand) |
| 51 | Cement plaster of mix 1:6 (1 cement : 6 fine sand)15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand) |
| 52 | Making of drip course in slab and sunshades including supply of all materials labour T&P complete. |
| 53 | 40mm thick 1:2:4 Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 54 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the .............With average thickness of 120 mm and minimum thickness at khurra as 65 mm |
| 55 | Providingandfixingglassstripsinjointsofterrazo/cement floors. 40 mm wide and 4 mm thick. |
| 56 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately |
| 57 | Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C.posts, struts, earth work and concrete to be paid for separately) :-Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire |
| 58 | Providing and fixingPVC soil, waste and vent pipesconforming to IS : 13592 Type A including jointing with seal ring c 5382 leaving 10 mm gap for thermal expansion, (i) Single sockete socketed pipes including all fittings like coupler , bends , tee etc complete. 110 mm diameter |
| 59 | Providing and fixingPVC soil, waste and vent pipesconforming to IS : 13592 Type A including jointing with seal ring c 5382 leaving 10 mm gap for thermal expansion, (i) Single sockete socketed pipes including all fittings like coupler , bends , tee etc complete. 75 mm diameter |
| 60 | Providing and fixing unplasticised -PVC pipe clips of approved desig unplasticised-PVCrainwater pipesbymeansof50x50x50m woodplugs,screwedwithM.S.screwsofrequiredlengthincl cutting brick work andfixingin cement mortar 1:4 (1 cement : 4sand) and making good the wall etc. complete. 75 mm |
| 61 | Providing and fixing unplasticised -PVC pipe clips of approved desig unplasticised-PVCrainwater pipesbymeansof50x50x50m woodplugs,screwedwithM.S.screwsofrequiredlengthincl cutting brick work andfixingin cement mortar 1:4 (1 cement : 4sand) and making good the wall etc. complete. 110 mm |
| 62 | Supply and fixing of 580 mm size white glazed vitrous China water closed Orissa WC pan including 100mm HCI pipe\"P\" or \"S\" trap with the rale and bend with CP brass hinses and rubber buffer 10 lit. capacity low level flushing cistern of approved make with fitting RS or CI brackets 30mm dia glaged flush pipe with fitting and clampes complete including fitting of cistern ,cutting and making good the wall and floor where required. |
| 63 | Providing and fixing white vetreous china wash including making all Flat back wash basin of size 630x450mm |
| 64 | Providing and fixing mirror of superior glass (of approved quality) and of Rectangular shape 453x357mm |
| 65 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 66 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall15 mm dia. nominal bore |
| 67 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall20 mm dia. nominal bore |
| 68 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work) 15 mm dia. nominal bore |
| 69 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work)20 mm dia. nominal bore |
| 70 | Providing and fixing uplasticised PVC connection pipe with brass unions 30 cm length 15 mm nominal bore |
| 71 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:893115 mm nominal bore |
| 72 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 73 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 15 mm nominal bore |
| 74 | Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats15 mm nominal bore |
| 75 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |
| 76 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 2 nos of 500 lits |
| 77 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : |
| 78 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks |
| 79 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 80 | Cleaning approach area and bush cutting |
| 81 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey With F.P.S. bricks |
| 82 | WGPVCPT Point wiring in PVC conduit, with piano type switch: Wiring for light point/ fan point/ exhaust fan point/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required.Light point |
| 83 | WGPVCPT Point wiring in PVC conduit, with piano type switch: Wiring for light point/ fan point/ exhaust fan point/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required.Tube light point |
| 84 | WGPVCPT Point wiring in PVC conduit, with piano type switch: Wiring for light point/ fan point/ exhaust fan point/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required.Fan point |
| 85 | WGPVCPT Point wiring in PVC conduit, with piano type switch: Wiring for light point/ fan point/ exhaust fan point/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required.exhaust fan point |
| 86 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVCconduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 87 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVCconduit as required.2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 88 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVCconduit as required.2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 89 | PTSWEB S/F piano type switch/ socket:Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required5/6 amps switch |
| 90 | PTSWEB S/F piano type switch/ socket:Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required3 pin 5/6 amp socket outlet |
| 91 | PTSWEB S/F piano type switch/ socket:Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required6 pin 15/16 amp switch |
| 92 | PTSWEB S/F piano type switch/ socket:Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required6 pin 15/16 amp socket outlet |
| 93 | PTSWEB S/F piano type switch/ socket:Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as requiredTelephone socket outlet |
| 94 | PPACCPT S/F power plug point plano type accessories: Supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 95 | WGPVCPP2 Power plug wiring in PVC conduit (2x4 sq. mm): Wiring for light/ power plug with 2x4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 96 | Supplying and flxing brass batten/angle holder including connection etc. as required. |
| 97 | EARCUPL Copper earth plate electrode: Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal or coke and salt as require |
| 98 | Supplying and fixing SP MCB 5 amps to 32 amps rating, 240 volts, \"B\" series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 99 | MCBTPIS S/F TP MCB isolator:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required. 40 amps DP Isolator |
| 100 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps DP Isolator |
| 101 | SPMCBDB S/F SP MCB DB:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnectios, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)8 way, Double door |
| 102 | Portan LED Luminare Light |
| 103 | S/F tube light |
| 104 | S/F LED Bulb 7Watt |
| 105 | S/F exhaust fan 150mm 900Cuft/min |
| 106 | S/F ceiling fans 1200 mmcomplete. |
| 107 | MODFREB S/F modular type electronic fan regulator: Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |