| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-08-2023 | Date Extension | Date | 11-08-2023 |
| 2 | 04-08-2023 | Revised Tender Conditions | Other | 09-08-2023 |
| Sl. No. | Item Description |
| 1 | Dismantling the Existing Reinforcement Cement Concretr and Clearing away from the Site etc., complete |
| 2 | Dismantling the Existing Brick Wall and Clearing away from the Site etc., complete |
| 3 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 4 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 5 | Supplying and filling in foundation andbasement with filling M Sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. |
| 6 | Providing and applying Levelling layer with Geo Textile of 120 GSM by heating the membrane by Butane Torch confirmig to the proporties specified in revelent European codes & specification etc, All complete. |
| 7 | Providing and applying PVC -Polyeric Membrane 2mm thick confirmig to the characteristics required for use in construction of UG Structures like Physical and Chemical properties specified in the revevent codes for ultimate tensil strength, alongation, impact strength, puncture resistance, hydrostatic pressure resistance, tear resistance to static punching (CBR), resistance to oxidation, Root resistance and Fire behaviour as per EN 13491 to achieve water tightness of Class - I ie, completely dry, including cost of fixing and fixtures as specified by the manufecturer and as shown in drawings and as per technical specification ect, all complete. |
| 8 | Dry Brick work in using II class chamber burnt bricks of size 9\"X43/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 9 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 10 | Refilling with excavated earth in layers of 30 cm watered well rammed and consolidatred conforming to standard specification including labour charges as directed by Engineer in Charge |
| 11 | Removal the surplus earth including debires up to 5km by tipper, over the initial lead of 10M and lift of 2M, depositing in places and spreading ect complete as directed by engineer at site. |
| 12 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D) Data 38Footing Plinth, Grade & Plinth Beam, Lintel Beam |
| 13 | Centering Vertical portion |
| 14 | Centering Rectangular or Square |
| 15 | Bottom Slab Portion |
| 16 | Providing and laying in position Standardized Concrete Mix M-25 Grade in accordance with IS 456-2000 using 20mm and downgraded hard broken granite stone jelly for all RCC of works with minimum cement concrete 0f 350 kg/m3 and maximum water cement ratio of 0.55 including admixture ( Plaster / super plasticizer ) in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete improve workability without imagining strength and durability with about (5.0cu.m) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cum) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering and also including laying vibrating with mechanical vibrators finishing curing etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra, etc,. Complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).For Basment Floor |
| 17 | For Ground Floor |
| 18 | For First Floor |
| 19 | For Second Floor |
| 20 | Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors |
| 21 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4\"X41/4\"X 21/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT For Ground Floor |
| 22 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4\"X41/4\"X 21/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT For First Floor |
| 23 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4\"X41/4\"X 21/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT For Second Floor |
| 24 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4\"X41/4\"X 21/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT For Third Floor |
| 25 | Plastering with cement mortar 1:3, 10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 26 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 27 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum |
| 28 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 29 | Supplying and erecting pull and push type rolling shutter with I.S.I. make of approved size and section using 18 gauge G.I.sheet with manually operated type. The Shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc, complete as per standard specification. |
| 30 | Supply and Delivery Fabrication of MS Ventilator with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete. |
| 31 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 32 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. - 100sq.mS.I.333 |
| 33 | Providing & fixing PVC RAIN WATER DOWN FALL PIPE of the following dia with necessary T.W.Clamps Plugs,Shoes,Bemds,other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removableiron gratings of appropriate size. The size of Teak Wood plugs used is150X25mm in front & 200 x 75mm in rear(wallside)with a depth of 110mm.The pipe is to be fixed by means of\"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 34 | Providing Rain Water Harvesting arrangements in corporation building by in serting of 150mm PVC slotted casing pipe, including earth work excavation for 900mm pre costcement Ring 5nos filling with One, three, Fifth Rings are 40mm metal and Two and Fourth Rings are Sand providing necessary pipe line arrangements eith std specification etc, complete. |
| 35 | PaintingNew wall surface with TwocoatofPlastic Emulsionpaint ofapproved quality including cleaning of plaster surface with soap soda and water by manual labour. |
| 36 | Paintingwith Ready Mixed Enamel Paint over the new Iron works of approved quality and colour with priming coatincluding the cost all materials etc., complete, in all floors. |
| 37 | ELECTRICAL WORKSWiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) SD24 |
| 38 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point SD38 |
| 39 | Supply and fixing of LED INDOOR FITTINGS (LIGHT EMITTING DIODE) 24W LED 4000K 2 x 2 Square Type Recessed Fitting with LED type Higher End light with TW round blocks on wall or ceiling with PVC unsheathed Copper leads from terminals to the fitting |
| 40 | Supply and fixing of single box type (philips / Havells / Eq) suitable for 4 feet 20W LED tube light with TW round blocks on wall or ceiling with 20W LED tube light with PVC unsheathed Copper leads from terminals to the fitting |
| 41 | Supply and fixing of 1200mm (48\") sweep AC ceiling fan (Crompton / Havells / Usha / Equivalent) with 2 module 100W regulator complete with 300mm down rod on existing clamp SD 111 |
| 42 | Supply and laying of 4 x 16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good |
| 43 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark (lik standard make)SD. 179 |
| 44 | Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour SD 57 |
| 45 | Supply and fixing of 48W LED Street Light Fitting LED OUTDOOR FITTINGS (LIGHT EMITTING DIODE)Higher End Philips / Havells / Equivalent etc., complete |
| 46 | Supply and fixing of 450mm (18\") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall |
| 47 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class \"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 48 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m |
| 49 | Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2\" x 1-1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete SD 131 |
| 50 | Supply and Erection of PASSENGER LIFTS (G+3) SS 304 Grade with 1m/sec. speed with ARD 8 Persons Passenger Lift Car Size (1300 x 1100) Gearless Lift with Machine Room |
| 51 | Supply and Erection of GENERATORS WITH AUTO MAIN FAILURE (AMF) PANEL 250 KVA |
| 52 | Toilet BuildingCharges for Putting borehole of size 23 / 30 cm dia for file foundation in Sandy and Other loose soil by using hand Boxing set Rate Shall be include the cost of Labour for Boxing Fule Charges for Auger Bore and Other T & P Employed etc., complete. |
| 53 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 54 | Supplying and filling in foundation andbasement with filling Quarry Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. |
| 55 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification. |
| 56 | Supplying and filling in foundation andbasement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 57 | Supplying,erectingwith necessarysupports for plain surface such as RCC Boxing side slab and silmilar RCC slab with all cross bracing etc., complete in all floors of any height ( the retrived materials ) should be taken back by the contractor the payment for cenetering shall be given after the concrete is laid ( For Rectangular or Square Columns) |
| 58 | Supplying,erectingSTEEL CENTERING forsides and soffits inc supports and strutting for plain surface such an reinforced cement concrete slasp rectangualar beams tee or el beams lintels , bed blocks staircase in all floors of any height (the retrived materials should be taken back by the contractor) the payment for cenetering shall be given by the concrete is laid (RCC column footing plinth, beam and lintel sides) |
| 59 | Supplying,erectingSTEEL CENTERING forsides and soffits inc supports and strutting for plain surface such an reinforced cement concrete slasp rectangualar beams tee or el beams lintels , bed blocks staircase in all floors of any height (the retrived materials should be taken back by the contractor) the payment for cenetering shall be given by the concrete is laid (bottom only) |
| 60 | Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCCitemsof works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and alsoincluding fixingfan clamps and fixtures in rccworkswherever necessary as directed by departmentalofficer etc., complete. For Basment Floor |
| 61 | Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCCitemsof works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and alsoincluding fixingfan clamps and fixtures in rccworkswherever necessary as directed by departmentalofficer etc., complete. For Ground Floor |
| 62 | Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors. |
| 63 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4\"X41/4\"X 21/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT For Basement Floor |
| 64 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4\"X41/4\"X 21/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT For Ground Floor |
| 65 | Plastering with cement mortar 1:3, 10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 66 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 67 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum |
| 68 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 69 | Supply and Delivery Fabrication of MS Doors with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete. |
| 70 | Finishing the top of floor with Granolithic Finish with CC 1: 2: 4 (one cement, two sand & four HBG jelly) using chips of grade 10 mm andbelow for 25mm thickness and rubbed smooth etc, complete as per standard specification 25 mm thick. |
| 71 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 72 | Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in positionincluding furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification. |
| 73 | R.C.C.Jolly by a new of followingsize in R.C.C. 1:1.5:3 using 20mm gauge hard broken granite stone jelly and river sand excluding cost of reinforcement but includingcharges,fabrication chargescuring neat finishing and labour charges for fixing the jolly in position with standard spefication. |
| 74 | Construction of inspection chambers of following sizes with earth work excavation for foundation with Dust Filling 10mm thick and Plain cement concrete bed in C.M. 1:5:10 using 40mm HBG jelly 10mm thick for foundation, 23cm thick brick wall work in C.M. 1:5 for chambers, Inner and Outer Plastering with C.M. 1:3 12mm thick, benching, channelling, 75mm thick RCC loose slab covering in C.M. 1:2:4 mix using 20mm blue granite jelly including necessary reinforcement, etc., complete 60mm X 60mm X 60mm |
| 75 | Supply and delivery of 2000 lit capacity and fixing of HDPE tank as per IS 12701/1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete as per standard specification. |
| 76 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch and making good of the concealed portion with suitable colourfor PVC concealed light / Fan Point (For electronic regulator) (5 Points Per Coil) SD -20 |
| 77 | Supply and fixing of single box type (philips / Havells / Eq) suitable for 4 feet 20W LED tube light with TW round blocks on wall or ceiling with 20W LED tube light with PVC unsheathed Copper leads from terminals to the fitting |
| 78 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. - 100sq.mS.I.333 |
| 79 | PaintingNew wall surface with TwocoatofPlastic Emulsionpaint ofapproved quality including cleaning of plaster surface with soap soda and water by manual labour. |
| 80 | Paintingwith Ready Mixed Enamel Paint over the new Iron works of approved quality and colour with priming coatincluding the cost all materials etc., complete, in all floors. |
| 81 | BOREWELL WORKSProviding Geological survey to fix the borewell point |
| 82 | Drilling 150mm dia borewell in all kinds of soils expect hood rock by first taking pilot bore and than enlarged to the required dia to enable to inserting the P.V.C. Casing pipe by directed rotary mud and circulation method including all labour and Water etc.. |
| 83 | Supply of 150mm dia P.V.C. Casing pipe |
| 84 | Labour charges for inserting 150mmPVC casing pipes assembly (with slot or without slots) in the drilled bore including jointing the pipesetc complete. |
| 85 | Drilling of borewell anywhere in-Tamilnadu including transportation from one place toanothar place within Tamilnadu in alluvaial soil or sedimentary strata of clay and sand or sand, stone, shale, pebbles, boulders etc., by first taking a pilot bore of 140/150mm dia and then enlarging to requierd dia by direct or reverse rotatry mud and circulation methd using contractor\"s rig, fuel, labour, drilling, at the site shown by the Deparment Officers including construction of mud pit. |
| 86 | Developing the borewell with air compressor of 300 cfm capacity (min 8 hours) including transportation labour and fuel charges for compressor as directed by corporation yield test by \"\"V\"\" notch method. |
| 87 | THREE PHASE SUBMERSIBLE PUMPSET SUITABLE FOR 150MM DIA-3HP BOREWELL AS PER IS 8034/2002 WITHOUT PANEL BOARD Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor asper IS 9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/-10%, 50HZ +/- 5 % , 50 lpm x 100mtr |
| 88 | THREE PHASE PANEL BOARD- D.O.L. WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to S13947 and IEC 947 suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). |
| 89 | Supply and deliveryof PVC insulated and sheathed 4.0sqmm copper cable conforming to IS 694/1990 suitable for submersible pump set. |
| 90 | Supply of PVC pipe and G.I pipes and PVC pipe & Specials.40mm UPVC Pipe |
| 91 | Nylon Rope (PWD Data 21 - 22) |
| 92 | 32mm GM gate Valve |
| 93 | 32mm GM non return Valve |
| 94 | 32mmGI Elbow |
| 95 | 32mm PVC Pipe(PWD Data 21 - 22) |
| 96 | 32mm PVC Coupling(PWD Data 21 - 22) |
| 97 | 32mm PVC Tee(PWD Data 21 - 22) |
| 98 | 32mm PVC Elbow(PWD Data 21 - 22) |
| 99 | 20mm Tap |
| 100 | 40mm Clamp set |
| 101 | 150mm borewell cover |
| 102 | Labour charges for erection of submersible pump set bore well including fixing and jointing submersible cable with proper clamps pressure gauge up to the exterior wall of pupm room kisok and erection of panel board consisting of TPCIN switches starter volt meter ammeter three indicator tamp capacitor single phase preventor ater level guard laying and jointing if cables and earthing complete the pumpset on trial for 3 days.. |
| 103 | Supply and delivery of 2000 lit capacity and fixing of HDPE tank as per IS 12701/1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete as per standard specification. |
| 104 | FIRE FIGHTINGSupply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 105 | Supply, and fixing in position of Fire FightingApplication Hose of 63mm dia of 15 metres lengthbinded by copper wire with 63mm dia stainless steelmale and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD /EQUIVALENT. |
| 106 | Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 107 | Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 108 | Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.80mm dia |
| 109 | 25mm dia |
| 110 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal 100mm Butterfly valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 111 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 112 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal 50mm Butterfly valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 113 | Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: HGURU / ISI MAKE / EQUIVALENT. |
| 114 | Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. Make: DONFOSS / INDFOSS / ISI MAKE / EQUIVALENT |
| 115 | Supply, erection, testing and commissioning of Fire Fighting Application direct on line main control panel to control electrical Terrace Pump Motor of 3.75 KW / 5 HP rated 415 volts / 50 Hz 3 phase, 2880 RPM including necessary auto / manual operations, over load relay, selector switches arrangements, voltmeter and ammeter provision, etc., as directed by the Departmental Officers. |
| 116 | Supply, erection, testing and commissioning of Fire Fighting 2 Way Fire Brigade Inlet with necessary gun metal 63mm dia non-return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. (Make: KIARTAR / OMEX / EQUIVALENT) |
| 117 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 118 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 119 | Supply, erection, testing and commissioning Mono Block type Fire Fighting Pressurisation Pump of 180 LPM 110 metres head at 10 HP with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges., etc., complete as per standard specification and as directed by the Departmental Officers. (Make: Kirloskar / Equivalent) |
| 120 | Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT. |
| 121 | Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 122 | Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 123 | Providing, fixing pipe supports from columns / wall or suspenders from roof slab to suit various dia of pipes made out of GI / MS adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening, arrangement design of hanger and should confirm with specification. |
| 124 | Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 125 | Supply, installation, testing and commissioning of Micro Processor based conventional 4 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 126 | Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Apollo / Equivalent) |
| 127 | Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent) |
| 128 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 129 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. |
| 130 | CCTV ArrangementCONFERENCE TYPE PUBLIC ADDRESS SYSTEM, PROJECTOR AND MOTORIZED SCREENARMOURED LAN & CCTV CABLE |
| 131 | PoE SWITCHES FOR CCTV IP CAMERA (4 Port) |
| 132 | NETWORK VIDEO RECORDER FOR CCTV (8 Channel - 1 SATA (1 No. Hard Disk)) |
| 133 | GST 18% |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy