Tender For Construction Of New Phc Building At Phc Kallar Vattayar (Final), kallar-Kerala

Wapcos Limited has published Tender For Construction Of New Phc Building At Phc Kallar Vattayar (Final). Submission Date for this Tender is 07-07-2023. Building Work Tenders in kallar Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

38361747
Tender For Construction Of New Phc Building At Phc Kallar Vattayar (Final)
Open Tender
Indian
Kerala
Kallar
07-07-2023

Tender Details

Construction Of New Phc Building At Phc Kallar Vattayar ( Final ) . 1 Civil Works 2 2.1.1 : Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 3 15.9.2 : Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 4 15.7.4 : Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 5 15.3 : Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. 6 15.19 : Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In-Charge. 7 15.28.1 : Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 8 15.23.1 : Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 9 15.12.1 : Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 10 15.6 : Extra For Scrapping, Cleaning And Straightening Reinforcement From R.C.C. Or R.B Work. 11 2.8.1 : Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 12 2.25 : Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M.Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 13 60.2.1 : Earth Work Filling- Supplying Contractors Own Earth Includingcost Of Conveyance Androyalty And Filling ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 14 4.1.8 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size ) 15 4.1.4 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 ) 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 40 Mm Nominal Size ) 16 5.9.5 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 17 5.9.3 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 18 5.33.1 : Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Siteof Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer - In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately.All Work Upto Plinth Level 19 5.33.2 : Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Siteof Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer - In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately.All Work Above Plinth Level Upto Floor V Level 20 50.6.1.2 : Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete. 21 13.16.1 : 6 Mm Cement Plaster Of Mix:1:3 ( 1 Cement : 3 Fine Sand ) 22 11.47.2 : Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 600X600 Mm 23 5.22.6 : Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 24 7.1.1 : Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) Up To Plinth Level With:Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 25 5.9.1 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 26 5.9.6 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 27 5.9.7 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, ( Excluding Landings ) Except Spiral - Staircases ) 28 5.2.2 : Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 29 51.13.21.1 : Water Proof Plasteringwith Cement Mortar 1:4 ( 1 Cement : 4 Fine Sand ) 12Mm Thick Plaster Finished With A Floating Coat Of Neat Cement Mixed With Water Proofing Compound Of Approved Make@ 2Kg / M2 Of Mix Floated Hard And Troweled Smooth Including All Labour, Material, Conveyancecharges Etc Complete. 30 13.43.1 : Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 31 13.46.1 : Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 32 13.52.1 : Finishing With Epoxy Paint ( Two Or More Coats ) At All Locations Prepared And Applied As Per ManufacturerS Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete.On Steel Work 33 13.61.1 : Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 34 8.2.2.2 : Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 35 8.3.2 : Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 36 11.39 : Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is: 15622, Of Approved Make In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 37 8.31 : Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineerin-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 38 9.147D.4 : Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 + / - 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable.Three Track Three Panels Sliding Window With Fly Proof S.S Wire Mesh ( Two Nos. Glazed & One No. Wire Mesh Panels ) Made Of ( Big Series ) Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 + / - 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. ( Area Of Window Above 1.75 Sqm ) . 39 9.117.2 : Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below ( Tolerance ±1 Mm ) , With Wall Thickness 2.0Mm ( ±0.2 Mm ) , Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size19 X 19 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 42X50 Mm 40 9.118.2 : Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride ( Pvc ) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm ( ± 0.2 Mm ) , With Inbuilt Decorative Moulding Edging On One Side.The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised / Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws.The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm ( ± 0.2 Mm ) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic / Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 41 50.9.1.1 : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood 42 50.9.4.1 : Providing And Fixing Paneling Or Paneling And Glazing In Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) Paneling For Paneled Or Paneled And Glazed Shutters 25 Mm To 40 Mm Thick Using Good Quality Anjili / Jack Wood 43 10.16.2 : Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Seamless Type Tubes 44 9.48.2 : Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc 45 9.53 : Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embeddings In Cement Concrete Block 30X10x15 Cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 46 9.62.1 : Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete:300X16 Mm 47 9.95.2 : Providing And Fixing Isi Marked Aluminium Butt Hinges Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete:125X63x4 Mm 48 9.97.2 : Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:250X10 Mm 49 9.100.1 : Providing And Fixing Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 50 9.101.2 : Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Twin Rubber Stopper 51 9.103 : Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock, Isi Marked, With Six Levers And A Pair Of Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868 ) Aluminium Lever Handles Of Approved Quality With Necessary Screws Etc . Complete. 52 13.1.1 : 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) 53 12.50 : Providing And Fixing Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm ( +0.05% ) , Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X55mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 Water Supply And Sanitation 55 50.18.7.3.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 10Kgf / Cm2- Internal Work- Exposed On Wall 56 50.18.7.4.1 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf / Cm2- Internal Work - Exposed On Wall 57 50.18.7.5.1 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 40 Mm Dia 10 Kgf / Cm2- Internal Work- Exposed On Wall 58 50.18.8.3.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 25 Mm Pipe 10Kgf / Cm2 59 50.18.8.4.1 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf / Cm2 60 50.18.8.7.1 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work Including Cutting Chases And Making Good The Wall Etc. 63 Mm Pipe 6 Kgf / Cm2 61 50.18.8.9.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 110 Mm Pipe 4 Kgf / Cm2 62 50.18.9.3.2 : Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.25 Mm Dia 10Kgf / Cm2 63 50.18.9.5.2 : Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Compete As Per Direction Of Engineer In Charge. 40 Mm Dia 6 Kgf / Cm2 64 50.18.9.7.1 : Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf / Cm2 65 50.18.9.9.2 : Providing And Fixing Pvc Pipes Includes Joints Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 110 Mm Dia 4 Kg / Cm2 66 50.18.9.10.1 : Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching , Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 150 Mm Dia 6 Kgf / Cm2 67 50.18.9.13.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 10 Kgf / Cm2- External Work - Exposed On Wall 68 50.18.9.15.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 40 Mm Dia 6 Kgf / Cm2 - External Work - Exposed On Wall 69 50.18.9.17.1 : Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps / Clip At 1.00 M Spacing .This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 6 Kgf / Cm2 - External Work - Exposed On Wall 70 50.18.9.19.2 : Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps / Clips At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 M Dia 4 Kgf / Cm2 - External Work - Exposed On Wall 71 50.18.9.21.7 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Vent Cowl 72 50.18.9.21.8 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia End Cap 73 50.18.9.22.1 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 74 50.18.9.22.2 : Providing And Fixing Pvc Moulded Fittings / Accessories Forrigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 75 50.18.9.22.3 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement-110 Mm Dia Door Elbow 76 50.18.9.22.4 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 77 50.18.9.22.5 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee 78 50.18.9.22.8 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia Vent Cowl 79 50.18.9.22.10 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia End Cap 80 50.17.1.5 : Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 81 18.17.3 : Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :40 Mm Nominal Bore 82 18.32.1 : Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Stop Cock, With C.I. Surface Box 100X100x75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S ( Non Modular ) Bricks Of Class Designation 7.5 83 18.52.1 : Providing And Fixing C.P Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is: 893115 Mm Nominal Bore 84 18.53.1 : Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 85 18.64 : Providing And Fixing Ptmtswivelling Shower, 15 Mm Nominal Bore, Weighing Not Less Than 40 Gms. 86 18.65 : Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138 Mm, Breadth 102 Mm, Height Of 75 Mm With Concealed Fittings Arrangements, Weighing Not Less Than 106 Gms. 87 19.7.1.1 : Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size, ) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weigh Of Cover 23 Kg And Weight Of Frame 15 Kg ) :With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 88 17.2.1 : Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 89 17.7.4 : Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400mm With Single 15 Mm C.P.Brass Pillar Taps 90 17.10.1.2 : Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink With Drain Board510x 1040 Mm Bowl Depth 225 Mm 91 17.28.1.1 : Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc. Waste Fittings Complete.Semi Rigid Pipe32 Mm Dia 92 17.31 : Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 93 17.73.2 : Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 94 17.34.1 : Providing And Fixing Toilet Paper Holder:C.P. Brass 95 18.48 : Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 96 Od81405 / 2023_2024 : Supplying And Fixing White Glazed European Water Closet, Wash Basin510x400 Mm, 750X100 Hinged Hand Rail-1 Nos, 600Mm Long Grab Bars-2 Nos And All Associated Accessories Like Flushing Cistern, Seat And Cover, Cp Brass Pillar Tap With Spatula Lever, Waste Coupling Etc. To Make The Toilet Functional For Special Need Persons Including Cutting And Making Good The Walls And Floor, Etc. Complete.<Br> 97 Od81408 / 2023_2024 : Supply And Fixing 110Mm Ss Gratings<Br> 98 Od81410 / 2023_2024 : Supplying And Fixing Nahni Trap With Cement Concrete Using 20Mm Broken Stones Including Cutting Open, Boring Through Masonry Walls, Rcc Floors Etc. And Making Good The Damages.<Br> 99 Od81411 / 2023_2024 : Constructing Silt Pit 20 X 20Cm Up To 60 Cm Depth Inside Dimension In Half Bric Trick Walls In Cm Alround Over Brick Jelly Concrete In Cm 1:3 For Foundation 15 Cm Thick, Plastering With C 1:3, 12 Mm Thick With Neat Cement Flushing Coat, Etc. Complete Including Providing 2 Nos. Heavy Cl Gra:Ngs, 150 X 150 Mm And 180 X 180 Mm For The Inside And Outside, Painted With Black Japan Two Coats And Necessary Earth Work Excavation Etc. Complete.<Br> 100 Od81413 / 2023_2024 : Supplying And Fixing C.I With Out Frame For Manholes:750 X 750 Mm Rectangular C Cover ( Medium Duty ) <Br> 101 Od81414 / 2023_2024 : Providing And Fixing Bib Cock With Wall Flange Of Approved Quality :<Br>15 Mm Nominal Bore<Br> 102 Od81415 / 2023_2024 : Providing And Fixing C.P. Brass Long Body Bib Cock ( Jaguar Or Equivalent ) Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.<Br>15 Mm Nominal Bore<Br> 103 Electrification 104 1.10.1 : Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group A 105 1.10.2 : Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 106 1.10.3 : Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 107 1.11 : Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. 108 1.17.3 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 1.5 Sq.Mm 109 1.17.12 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5 Sq. Mm 110 1.17.21 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 4 Sq. Mm 111 1.14.10 : Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 112 1.21.1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 113 1.21.2 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 114 1.28.1 : Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.1 Or 2 Module 115 1.19 : Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 116 1.24.7 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Tv Antenna Socket Outlet 117 1.18.2 : Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pair 118 1.24.6 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Telephone Socket Outlet 119 1.31 : Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 120 1.56 : Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlets And 2 Nos. 5 / 6 A Modular Switches, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 121 1.58 : Supplying And Fixing Pvc Batten / Angle Holder Including Connection Etc. As Required. 122 1.25 : Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 123 90.4.1 : Supply And Installation Of Suitable Size Ms Rod Type Fan Clamp In The Rcc Slab As Per Is 732 As Required. 124 90.10.3.15 : Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) 125 90.10.3.32 : Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) 126 90.10.3.33 : Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) 127 90.12.1.41 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) . 128 90.12.5.41 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc / Hume / Stone Ware / Gi / Dwc Pipe As Required. 129 90.12.7.41 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. 130 9.1.33 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) 131 2.10.1 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 132 2.13.2 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 133 2.13.1 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 134 2.15.2 : Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 135 90.11.1.10 : Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required 136 90.16.1.3 : Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required 137 90.16.5.3 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 138 5.3 : Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. ( But Without Charcoal / Coke And Salt ) As Required. 139 Od81399 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Following Exhaust Fan In The Exisitng Opening, Including Making The Hole To Suit The Size Of The Above Fan, Making Gooddamage, Connection, Testing, Commisioning Etc. As Required. ( A ) 230 Mm ( Make:- Almonard - Light Duty ) <Br> 140 Od81400 / 2023_2024 : Kseb Meter Board.. Fabrication, Supply Erection Testing And Commissioning Of Metering Board With Dust And Vermin, Weather Proof, Made Out Of 16 Swg Powder Coated Crca Sheet. The Board Should Be Chemically Treated And Coated With Two Coats Of Metal Primer And Two Coats Of Siemens Grey Enamel Paints. Including Hrc Fuse Link, 160A Sfu With 4Numbers Ct Provision Including Ct. Appro. Size Or Fiber Type Provision For Three Phase Meter ( Kseb ) - 1Sets. Including Handles , All Connecting Items Fuses Etc.., .160A Hrc Fuse 3Nosor Grp, Fiber Type Depend On The Site Condition<Br> 141 Od81401 / 2023_2024 : Fabrication, Supply & Installation Of Dust And Vermin Proof, Wall Mounting, Three Phase Meter Box Of Suitable For Fixing Kseb Meter, Fuse Units, Ct Etc, Hinged Door Construction For The Front Side With Compartments If Necessary, Providing Vision Panel For The Meter Compartment, Knock Out For Cable Entry And Exit With The Following. <Br>63A 415V Fuse- 3 Nos. 63A 415V Neutral Link- 1 No<Br> 142 Od81402 / 2023_2024 : Supply And Fixing 9 W Led Bulb Make Philips / Govt Approved Reputed Brand As Required.<Br> 143 Od81403 / 2023_2024 : Supply Installation Testing And Commissioning Of 45W Led Top Light With Complete Set ( Group-A ) Govt Approved And Reputed Brands On 25 Mm Or Nearest Suitable Size B Class Gl Pipe 1.5 M Long Cut And Weld, Bend To Shape Fixed On Wall Using Flat Iron Clamps Fabricated Frpm 25X3 Mm Ms Flat Giving Connection With Required Length Of 24 / .20Mm Pvc Insulated And Pvc Sheathed 650 / 1100V Grade Round 3 Core Copper Conductor Conforming To Relavant Iss Painting The Gl Pipe And Clamps With All Necessary Items Making Good The Surface As Required.<Br><Br> 144 Od81404 / 2023_2024 : Supply Installation Testing And Commissioning Of 20W Surface Mounted Le In Giving Connection Etc Complete As Required<Br> 145 Od81406 / 2023_2024 : Supply Of 20W Led Tube Light Fitting Have 2000Lumen With Duly Wired Up For Use On 330 V Ac. The Fittings Shall Be Directly On Ceiling / Well, Including All Accessories Etc. As Required. Make Equivalent<Br> 146 Od81407 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Plastic Body Type 6 Inch S Ze Exhaust Fan Of Govt Approved Makes Like Crompton, Havells, Bajaj Or Equivalent Make Giving Connection Etc Complete As Required<Br> 147 Od81409 / 2023_2024 : Supply, Conveyance, Installation, Lesting And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories, Wiring The Down Rod With 16 / 0.20Mm Pvc Insulated And Pvc Sheathed 650 / 1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. -1200 Mm Sweep Ordinary Fan <Br><Br> 148 Od81412 / 2023_2024 : Supply, Installation, Testing And Commissioning Of 12 W Led W H Bulk Head Light Fitting Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Rourd Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required.<Br> ( Mlabs Wipro / Philips / Bajaj / Luker / Havells. Prior Sample Approval Has To Be Obtained From The Concerned Authority Before The Fitting Is Installed ) &Apos;&Apos; <Br><Br><Br> 149 Septic Tank And Soak Pit- 150 2.8.1 : Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 151 2.25 : Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M.Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 152 2.26.1 : Extra For Every Additional Lift 1.5 M Or Part There Of In Excavation / Banking Excavated Or Stacked Materials.All Kinds Of Soil 153 4.1.8 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size ) 154 5.9.1 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 155 5.9.2 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 156 5.9.3 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 157 5.1.2 : Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 ( 1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size 158 5.2.2 : Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 159 5.3 : Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . 160 51.13.21.1 : Water Proof Plasteringwith Cement Mortar 1:4 ( 1 Cement : 4 Fine Sand ) 12Mm Thick Plaster Finished With A Floating Coat Of Neat Cement Mixed With Water Proofing Compound Of Approved Make@ 2Kg / M2 Of Mix Floated Hard And Troweled Smooth Including All Labour, Material, Conveyancecharges Etc Complete. 161 5.22.6 : Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 162 13.1.1 : 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) 163 19.32.1 : Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5

Key Value

Document Fees
INR 5900 /-
EMD
INR 50000.0 /-
Tender Value
INR 1.23 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail