|
| 1 | Demolition of cement concrete from Sunkan portion of toilet including surface finishes of any type such as Mosaic, terrazo tile / tiles complete all as specified and directed. |
| 2 | M&L cleaning surface of sunken portion of toilettaking out existing material from wall / bottom and applying cement slurry @ 1.2 Kg per Sqm and applying for 15 mm thick renderingin CM (1:3) admixed with integral water proofing compound FOSROC\"s complast X 421 IC @ 130ml per bag of cement incl a bonding two coat of FOSROC\"s Nito bond AR cement slurry / STP NO 1 liquid @ 200ml per bag finished even and fair using extra cementto make the surface leak proof complete all as specified and directed.Note:- Contractor may use equivalent make of admixture / bonding coat as approved by GE |
| 3 | M&L formass concerte Type E-2, 1:5:10 using 40mm graded stone aggregate filling in Sunken portion complete all as specified and directed. |
| 4 | S & F 40 mm dia Tubes, \"medium grade\" galvanised, fixed as spout pipe in sunken floor fixed with cement mortar. |
| 5 | M & L for Providing, Type B1, 1:2:4 (20mm graded aggregate) cement concrete in roof kerbs or mud stops, rounded or chamfered on edges |
| 6 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge |
| 7 | S & F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixedwithcoach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or crankedhook bolts in lieu of screws, complete all as specified and directed by Engineer-in-Charge. |
| 8 | All as per item No 07 but except SheetsNote : Old sheets obtained from item No06 will be used. |
| 9 | Dismantling Framed timber scantling, 40 Sqcm and over in section in any position including rafters and purlins, wooden planks |
| 10 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 11 | M & L Rolled mild steel in roof trusses (framed), trussed, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engineer-in-Charge |
| 12 | M & L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe- 290 (Gde E- 165) (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 13 | S & F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 |
| 14 | M & L for tightening bolts and closing bolt holes, etc.to rectify the leakage/ seepage, in old roof of corrugated steel sheets by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts if required, all set in stiff white lead Complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for Preparing new zinc (or galvanised) surfaces to receive painting, by coating with mordant solution including washing and cleaning, etc steel and iron surfaces and applying two coat of synthetic enamel paintof any description over 10cm width or girth in Camouflaging CCD pattern as approved complete all as specified and directed by Engineer-in-Charge |
| 16 | M&L for Second Class hard wood and scantling timber framed and fixed wrought |
| 17 | Dismantling boarding, any description, fixed in any position withnails in existing wooden slab complete all as spercifed. |
| 18 | M&L for Second class hard wood clean sawnplanks,width n exc. 20 cm and 20mm thick fixed in existing wooden eves board complete all as spercifed. |
| 19 | S & F for in repair Wooden planks of second class hard wood, 20mm thick, planed one side and edges tongued and grooved or rebated fixed, inrepairs to replace old and or decayedboarding in patches including cutting out old, piecing, heading joints, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material and labour for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to new steel surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and as directed. |
| 21 | Material and labour for applying one coat of synthetic enamal paint onsteel surface of any description over 10cm widht or girthincluding preparation of old painted surfaces complete all as specified and as directed. |
| 22 | Material and labour for two coats of synthetic enamel paint over a coat of pink primer to new wooden surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and as directed. |
| 23 | M&L for providing cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundations,filling and mass concrete complete all as specified and as directed |
| 24 | Disconnecting existing water tanks exc 500 liters and n.exc 1000 liters setting aside(or lowering if reqd ) including ,Material and labour for cleaning and removing all scale,dirt and funges etc. from tanks and mouth of circulating pipes, with suitable cleaning chemical and brushing the wall and bottom of tanks, washing with clean water, writing letter i.e. \"TANK CLEANED ON ......................(Date)\" not exc. 100mm height with synthetic enamel paint for tanks of capacity 500 ltrs to 1000 ltrscomplete all as specified and asdirected. |
| 25 | Dismantling Wallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F snap grid for false ceiling of size 600 mm x 600 mm grid EXPOSED GRID SYSTEM fabricated with glavanised iron powder coated section all as shown on serial page No 185 of SSR part II (2020 print) complete all as specifieddirected by the Engineer-in-Charge. |
| 27 | M &Lfor Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw size (600x600 mm) as per manufacturers instructions including necessary jointing and taping, and applying 1mm thick putty to receive finishes complete all as specified and directed by Engineer-in-Charge. |
| 28 | S & F in repair Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws putty to receive finishes complete all as specified and directed by Engineer-in-Charge. |
| 29 | M&L for preparation of new or previouly untreatedplaster/ AC sheet/Gypsum board surfacesof ceiling including cornices and applying two coats of oil bound distemper colour/tint complete all as specified and directed by Engineer-in-Charge. |
| 30 | M&L for preparation of old ceiling surface and applying one coats of distemper oil emulsion (OBD) includingcomplete all as specified and as directed by Engineer-in-Charge |
| 31 | Taking down 15 mm dia GI steel tubing and connection, including cleaning for refixing or removal, completed all as specified and directed. |
| 32 | Taking down 20 mm dia GI steel tubing and connection, including cleaning for refixing or removal, completed all as specified and directed. |
| 33 | Taking down 25 mm dia GI steel tubing and connection, including cleaning for refixing or removal, completed all as specified and directed. |
| 34 | Refixing of old steel tubing and connection in new or old position of 15 mm bore complete all as specified and directed. |
| 35 | S&F GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors 15mm bore complete all as specified and directed. |
| 36 | Refixing old GI tubing and connections, 20 mm dia,in old or new position. (Walls, ceiling, floors, etc.) completed all as specified and directed. |
| 37 | M & L tubes 20 mm bore dia, medium grade, galvanised, with allfitting and fixed complete to walls and ceilings or laid in floors,complete all as specified and directed. |
| 38 | Refixing old GI tubing and connections, 25 mm dia,in old or new position. (Walls, ceiling, floors, etc.) completed all as specified and directed. |
| 39 | M & L tubes 25 mm bore dia, medium grade, galvanised, with allfitting and fixed complete to walls and ceilings or laid in floors,complete all as specified and directed. |
| 40 | Cutting chases pinning in making good to facing where required and pointing in cement mortar (1:3) for concealed water tubing in brick walls cutting n.exc 10 cm girth. complete all as specified and directed. |
| 41 | S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks and removing from site including 20 mm Ball brass valves, high pressure, with polythene float and flynut complete. |
| 42 | S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks and removing from site including 20 mm Ball brass valves, high pressure, with polythene float and flynut complete. |
| 43 | S & F in repairs 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 44 | S & F in repairs 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 45 | S & F in repairs 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 46 | S&F in repairsstop cock/angle cock fancy typewith long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. |
| 47 | S&F in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed. |
| 48 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge |
| 49 | S & F Factory made PVC solid single door frame (chowkats) of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening all as specified in SSR part-II 2004 Section-8, clause 8B.3 to 8B.3.2 and shown on drawing in SSR part-II 2020. |
| 50 | S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plaincolour PVC© channel PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock and bottom rail on either side as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded. Sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing. |
| 51 | S&F100 mm size butt hinges, Stainless Steel complete all as specified and as directed by Engineer-in-Charge. |
| 52 | S&F 150 mm long aluminium anodized barrel tower boltsof extruded section complete . |
| 53 | S&F 150 mm size, aluminium anodized handles, cast type complete all as specified and directed by Engineer-In-Charge. |
| 54 | S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including trap set complete all as specified and directed. |
| 55 | S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) |
| 56 | S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed. |
| 57 | Dismantling ofPVC drain pipes, 75/100 mm dia, jointed with rubber ring and taking out from trenches / walls Complete all as specified and directed by Engr-in-charge. |
| 58 | S&F PVC (SWR) soil waste and vent pipes single socketed 110mm dia bore in any length withrubber ring joints, fixed to walls, complete all as specified and directed |
| 59 | S&F PVC (SWR) soil waste and vent pipes single socketed 75mm dia bore in any length withrubber ring joints, fixed to walls, complete all as specified and directed |
| 60 | S & F in repair 75 mm diaPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 61 | S & F in repair 110 mm diaPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 62 | S & F in repair 75 mm dia PVC (SWR) bends any radius with acess door |
| 63 | S & F in repair 110 mm dia PVC (SWR) bends any radius with acess door |
| 64 | S & F in repair 75 mm dia PVC (SWR) branch piece, double (double Y) equal or unequal provided with access door |
| 65 | S & F in repair 100 mm dia PVC (SWR) branch piece, double (double Y) equal or unequal provided with access door |
| 66 | S & F in repair PVC (SWR) \"P’ trap 110mm |
| 67 | S & F in repair PVC (SWR) \"S’ trap 110 |
| 68 | S & F in repair PVC (SWR) 75mm multi floor trap with grating including jointing with solvent cement |
| 69 | S & F in repair PVC (SWR) 75mm floor trap, plain with grating including jointing with solvent cement |
| 70 | S&F PVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed. |
| 71 | S & F in repair 15mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142 gms) complete all as specified and directed by Engineer-in-Charge. |
| 72 | S & F in repair 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 73 | S & F in repair 25mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 74 | Demolation of floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed. |
| 75 | M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortarfor laying floor finishes in CM 1:6 |
| 76 | Material and labour for ceramic (Non skid) tilesarea of each tile exc 0.11 sqm but n exc 0.18 sqmx7 mm thick, as infloors,setand jointed in neat cement slurry and pointed in white cement withpigment to match the colour of tiles bedded over and including 15mm thickpigment to match the colour ofscreed in cement mortar 1:6 complete all as specified. |
| 77 | All asper item 76 above but on vertical surface such as skirting, dados andrisers to steps etc set and jointed in neat cementslurry and pointed in colour cement to match including 10mm thick cement plaster with cement mortar 1:4 |
| 78 | Material and labour for any coloured glazed ceramictiles size of tiles 600mm x300mm thick onvertical surface such as skirting, dados andrisers to steps etc set and jointed in neat cementslurry and pointed in colour cement to match including 10mm thick cement plaster with cement mortar 1:4 |
| 79 | Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 80 | Material and labour for25mm thick cement concretetype B-0 (1:2:4) using 12.5 mm graded stone aggregate as in sub base of floorfinish even and rough to receive further floor finishes ( tile/kota stone/ marble ), complete all as completed all as specified and directed. |
| 81 | M&L for heavy duty exterior grade tile texured finish of 400 x400 x 10 mm thick vitrified tile laid over and including 10 mm thick rendering in CM 1:4 as in steps complete all as specified and directed |