| 1 | Fire Fighting system |
| 2 | 90.17.4.2:Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head |
| 3 | 90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) |
| 4 | 90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 5 | 90.14.3.2:Supply and providing heavy duty \"A\" section neoprene gasket in the panel boardU\" section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 6 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 7 | 90.14.7:Supply and providing copper earth bus in the panel board |
| 8 | 90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 9 | OD201591/2022-2023:Supply , Conveyance, Installation, Testing and commissioning of single phase preventer suitable for existing motor starter and giving necessary connections etc as required (L&T or Techno commercial Equivalent) |
| 10 | OD200148/2022-2023:Supply and fixing Red, Green, blue, Yellow, Orange colours LED indicator, AC/DC, as required |
| 11 | OD200140/2022-2023:Supply and fixing selector switch in the existing motor control panel and giving necessary connections as required |
| 12 | OD200149/2022-2023:Supply and fixing Digital Multifunction meter to read: V, A, F, PF-3 phase accuracy class 1 LED and giving necessary connections as required. |
| 13 | OD200174/2022-2023:Supply and fixing 40/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT and giving necessary connections as required. |
| 14 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 15 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 16 | 90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm |
| 17 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 18 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 19 | OD200150/2022-2023:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5 Sq mm single run |
| 20 | OD200151/2022-2023:Providing and fixing following capacity TP&N/4P switch disconnector unit(SDU) inside the existing panel boardincluding drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP&N/4P(Isolator) |
| 21 | OD201501/2022-2023:Supplying and providing 25 mm Corrugated PVC flexible conduit as required. |
| 22 | OD201502/2022-2023:Supplying and providing 20 mm Corrugated PVC flexible conduit as required. |
| 23 | 90.17.7.7:Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia |
| 24 | 90.17.11.5:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 25 | 90.17.14.5:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia |
| 26 | 90.17.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b. 20 mm nominal internal dia gun metal globe valve & nozzle.c. Drum and brackets for fixing the equipmets on wall.d. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m |
| 27 | OD200141/2022-2023:Supplying, fixing, testing and commissioning of 25 mm Air release valve as per IS:14845 as required |
| 28 | OD200142/2022-2023:Supply and providing pressure gauge in the existing system as required |
| 29 | 90.17.22:Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required |
| 30 | OD200137/2022-2023:S I T C of 25 mm dia Bronze Ball Valve with ISI mark(Zoloto make/Equivalent) |
| 31 | OD200143/2022-2023:Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way - 63 mm dia M.S. Pipe |
| 32 | OD200135/2022-2023:Supplying and installing in position LED "FIRE EXIT" sign boards of suitable size with battery backup. |
| 33 | OD200136/2022-2023:Supply and installing in position laminated sheet of " FIRE EVACUATION PLAN " of suitable sizefixed on wall & necessary accessories to fix the plan on wall. |
| 34 | OD200139/2022-2023:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB / Fire & rescue service Department/ KSEB etc - First A3 Sheet |
| 35 | OD200138/2022-2023:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB / Fire & rescue service Department/ KSEB etc - Each Additional A3 Sheet |