| 1 | Dismantling of wrought iron or mild steel work of any description and in any position not otherwise provided for. |
| 2 | Dismantling of old damaged chain link fencing wiremesh any type and size |
| 3 | Demolition of cement concrete (un re-inforced) in ground floor and paving not exc. 15 cm thick below or above ground level complete all as specified and directed. |
| 4 | S&F MS framed work such as grills, Gratings, manholes covers flat iron as in chain link fencingetc with ends of bars shouldered or riveted, frame work of water tanks and similar work conform to Fe 290. Gde E 165 all as specified and directed. |
| 5 | Dismantling of posts or struts (RCC fencing posts) any section and taking out embedded portion (post embedded in concrete.)including making good to disturbed complete all as specified and directed. |
| 6 | Excavating in post holes (or similar holes) each not exc. 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard/ dense soil complete all as specified and directed. |
| 7 | S&F MS angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, bolting etc and similar works conforming to Fe-290 Gde E-165. complete all as specified and directed. |
| 8 | M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation/fencing post fixing all as specified and directed |
| 9 | Supply only chain link MS galvanised fencing, any size or type all as directed by Engr-in-Charge. |
| 10 | Fixing only chain link fencing including line wires any mesh size and type to any type of standards rails straining bolts etc including provision of binding wire. (Note : Line wire shall be measured and paid seperately as supply only) |
| 11 | S&F MS screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut n.exc. 5cm long and dia of shank 8 to 10 mm etc. complete all as specified and directed. |
| 12 | S&F 10mm dia MS round bars conforming to Fe 410-O as in straining bars in fencing all as specified and directed. |
| 13 | M&L for preparation of new steel surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed. |
| 14 | Dismantling of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. and precast concrete article complete all as directed. |
| 15 | S&Fin repairs galvanised 2 strand steel barbed wire 2.24mm, dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire staples or steel pins all as directed. (Each line wire to be measured) |
| 16 | Dismantling structural steel work including doors, gate but excluding framed truss etc complete all as specified and directed. |
| 17 | M&L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed |
| 18 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and directed. |
| 19 | Materials and labour for plain cement concrete (1:4:8) Type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed. |
| 20 | M&L precast solid block masonry of block in cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed. |
| 21 | All as per item No. 20 above, but except PCC block complete all as specified and directed.Note: Old serviceable PCC block retrieved from item No.14 above will be reused. |
| 22 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:4 complete all as specified and directed. |
| 23 | All as per item No. 22 above, but except stone.Note : Old serviceable stone retreived from item No.14 above will be reused. |
| 24 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified of face beds and joints as specified of random rubble walling, uncoursed or brought upto courses with 40mm maximum depression on face from straight edge held against the dressed surfaces complete all as specified and directed. |
| 25 | Taking down cement or cement lime plasteron brick or stone walls etc including raking out joints, hacking for key, scrubing down with water etc. complete all as specified and directed |
| 26 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for preparing surface of plastered or unplastered and applying two coats of cement base paint complete all as specified and directed |
| 28 | M&L raised pointing to random rubble or polygonal rubble, uncoursed or brought upto course in CM 1:4 including raking out old pointing complete all as specified and directed. |
| 29 | M&L raised pointing in CM 1:4 to random rubble or polygonal rubble, uncoursed or brought upto courses complete all as specified and directed. |
| 30 | M&L for Razor concertina Coil, 610mm dia (50 spirals per coil) weight approx 8 Kg (+ or -5%) expandable 6-8 mtrs, consisting of 2.6 mm dia. Heavy galvanised high tensile spring steel wire as per IS-4454, barb (Barb length 24 + or -1mm, pitch between two barb 35 + or -1mm) wade of 0.5mm thick low carbon heavy galvanised cold rolled steel sheet as per IS-513, heavy duty steel clip as per IS-2062 and Epoxy resin coating for anti-corrosion, incl dismantling old fencing wire any type all as specified and directed. |
| 31 | M&L RCC 1:2:4, type B1(using 20mm graded stone aggregate) as in foundation, including rafts, footings, foundation, beams, plinth beams, base for columns etc basement slab under reamed piles and mass concrete complete all as specified and directed. |
| 32 | M & L for use and waste of formwork to side of concrete foundation, footings, bases of columns, rafts beams, sides and soffits (if any) of foundation and similar work fair finished concrete surface complete all as specified and directed. |
| 33 | M & L for use and waste of formwork to sides of soffits of floors or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc finished fair surface complete all as specified and directed. |
| 34 | M & L for use and waste of formworks to edges of concrete flats, trades breaksin floors, window cills, concrete railings, opening in concrete walls, floors and roofs not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but not exc. 20cm wide rough finished surface of concrete flat complete all as specified and directed. |
| 35 | M&L MS TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 36 | All as per item No. 35 above, but 5mm dia and over upto and including 10mm dia in strriups and binders complete all as specified and directed. |
| 37 | Demolition of reinforced cement concrete of any position not otherwise specifically provided (reinforcement cut as required to facilitate demolition) all as specified and directed |
| 38 | M&L PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in wall, for embedding angle iron post including necessary form work complete all as specified and directed. |
| 39 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5 m depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc not exc. 10 sqm on plan and not exc. 1.5 m in dedpth and getting out in hard/dense soil complete all as specified and directed |
| 40 | Removing excavated material (soil) not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 41 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and directed. |
| 42 | Dismantling stone slab laid bedded and pointed in cement mortar of any description or thickness in floor aprons etc complete all as specified and directed. |
| 43 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the premises |
| 44 | M&L 75mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed |
| 45 | M&L 25mmthick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) and finished even and fair to receive the further treatment complete all as specified and directed. |
| 46 | M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection including necessary use and waste of form work complete all as specified and directed. |
| 47 | M&L 100mm thick cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in floor and finished even and fair without using extra cement) complete all as specified and directed. |
| 48 | M & L Forming 12mm thick expansion joint filled with pre formed bitumen filler and top 30mm primed and sealed with sealing compound grade A thickness of concrete slab 100mm complete all as specified and directed. |
| 49 | Finishing the surface of concrete pavements by brooming complete all as specified and directed. |
| 50 | M&L 25mm thick rough dressed lime stone slab flooring , jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed |
| 51 | M&L machine cut cudappa stone slab 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 52 | M&L 20mm thick granite (of any type) work, in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 53 | M&L non skid ceramic coloured tile 7 to 8mm thick (square/rectangular) area of each tiles exceeing 0.11 sqm but not exceeding 0.18 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6complete all as specified and directed. |
| 54 | M&Lglazed ceramic coloured tiles in vertical surfaces such as dado, skirting, risers of steps and pillars of size 450x350x7 mm thick set and jointed in neat cement slurry incl pointed in white or colourcementto match the shade of tiles, over and inclrendering15mm thick 1:4 complete all as specified and directed. |
| 55 | M&L light shade vitrified ceramic coloured tile 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 56 | All as per item No.55 above, but on vertical surface such as skirting, dado, risers of steps, pillars etc but including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 57 | S&F in repair stainless steel sink , made out of 1.00 mm thick sheet for kitchen with plug, washer pipe cast iron cantilever brackets, connecting union overall size 495x420mmbowl size 410mm x 330mm x160mm all as specified and directed. |
| 58 | S&F in repair 15mm fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete as specified and directed by Engr-in-Charge. |
| 59 | Taking up or down 15 mm bore steel tubing and connnections, including cleaning for refixing orremoval all as directed. |
| 60 | S&F galvanised tubes 15mm bore, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and directed. |
| 61 | Refixing 15 mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc) all as specified and directed. Note :- Serviceable tubing obtained from Sl item No.59 is re-used in this item. |
| 62 | Cutting chase, pinning in making good to facings where required & pointing in cement mortar 1:3 to ends etc or edges of landings, steps cills, sunshades, shelves, lintels, etc and cutting chasesfor concealed water tubing and making good, cutting not exc. 10cm girth in brick walls all as directed. |
| 63 | S&F vitreous china squatting pan \"Orrisa Pattern\" size 580x440mm white with integral foot rest (including flushing cistern) but including flush pipe, trap complete all as specified and directed. |
| 64 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (including fixing bolts, flushing cistern and flush pipe) including provision of flush pipe, plastic seat cover for pedestal pan and CP health faucet including two way angle cock complete all as specified and directed. |
| 65 | S&F in repair vitreous china wash basin, white, flat back, size 630x450mm excluding taps, waste chain and plug and porcelain stopper but including brackets, waste coupling and waste pipe including pillar tap and stop cock complete all as specified and directed. Make : cera |
| 66 | S&F in repair 15mm dia stop valve chromium plated fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and directed. |
| 67 | S&F in repair 15mm brass CP mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed. |
| 68 | M&L machine cut kota stone slab as in flooring20-25 mm thick over and including 15mm thick (avg thickness) cement screed in CM 1:6 base, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl cutting , waste, rubbing and polishing (granite finish) etc complete all as specified and directed. |
| 69 | M&L machine cut kota stone slab as in skirting 20-25mm thick in riser of steps, skirting, dado and pillar inclu 15mm thick (avg thickness) rendering in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl cutting, waste, rubbing and polishing (granite finish) etc complete all as specified and directed. |
| 70 | M&L coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick set pointed with neat cement slurry with grey cement and pigment in floorsover and including 15mm thick screed bed in cement mortar 1:4complete all as specified and directed. |
| 71 | M & L machine pressed precastconcrete interlockingpaver block with grey cement and no pigment, any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 grade with glossy finish, colour shade including 50 mm thick sand cushioning all as specified and directed. |
| 72 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down old existing PVC/ cast iron pipe complete all as specified and directed. |
| 73 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down old existing PVC/ cast iron pipe complete all as specified and directed. |
| 74 | S&F in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed |
| 75 | Dismantling water tanks and removing capacity exc. 500 & not exc.1000 ltrs complete all as specified and directed. |
| 76 | S&F 1000 ltr. Capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 77 | Dismantling water tanks and removing capacity exc. 250 & not exc. 500 ltrs complete all as specified and directed. |
| 78 | S&F 500 ltr. Capacity rotational moulded polyethylene water storage tankscylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 79 | S&F 750 ltr. Capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 80 | M&L 15mm thick cement plastering on stone masonry surfacesin CM (1:6) finishing surfaces even and fair without using extra cement over and including 10mm thick dubbing out on irregular face of wall in CM 1: 6including taking down existing plastering of any description complete all as specified and directed. |
| 81 | Dismantling of plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof covering |
| 82 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed. |
| 83 | S & F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley, gutters etc. complete all as specified and directed. |
| 84 | S&F Framed work such as roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde E-250) Quality \"A\" complete all as specified and directed. |
| 85 | S&F rolled sections as in main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc Fe-410-W (Gde E-250) Quality \"A\" complete all as specified and directed. |
| 86 | M&L 18/19mm thickPre-laminated board exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to timber frame including taking down existing board of any description complete all as specified and directed. |
| 87 | Dismantlingwall and ceiling boards (fibre, pulp, insulation boards/slabs/blankets, any thickness, including cover fillets |
| 88 | M & L for false ceiling with 4mm thick designer\"E\" board fixed on GI grid work with powder coated finish on exposed surface of size 0.6 x 0.6m consisting of GI angle supported on wall of size 24mm x 28 x 0.7mm main tee of size24mm x38mm x 0.7mm cross tee of size24mm x 28mm x 0.7 mm using purpose made members interlocking to each other and with 40mm x 3mm flat GI mild steel strip suspender made to shape at 1200mm c/c fixed with 3mm dia GI wireand making holes etc all as directedincluding two coats of white wash on ceiling after preparation of surfaces and as per manufacture instruction make of GI Grid work : Armstrong/Swastik/Techno Grid and MakeE boardGypsum or equivalent approved . |
| 89 | Extra over rates of block board or veneered particle board for external teak wood 18/19mmlipping 6mm thick fixed with nails |
| 90 | M&L rendering 5mm thick on concrete surfaces in CM 1:3 on ceiling, finished even and smooth with sagol all as specified and directed. |
| 91 | M&L preparing newly plastered surfaces of wall and applying complete wall with POP/Birla putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed by Engineer-in-Charge. |
| 92 | M&L for preparation of newly plastered surfaces of ceilingand applying complete ceiling with 3mm POP/Birla putty and making smooth surface and applying three coats of white wash over a coat of POP/Birla puttyall as specified and directed. |
| 93 | (Applicable for above allitems) |
| 94 | Contrator has to employ skilled/unskilled tradesman with adequate experience & required documents to be submitted to office. The rate shall be quoted by the contractor including scaffolding to carry out the work for height more than 10.00 mtrs. |
| 95 | Labour should wear contractors uniform with firm logo, failing which recovery shouldbe made. |
| 96 | Minimum of 02 x teams of each trades shall be available for maint of urgent nature whenever called upon of any trade, failing which recovery will be initiated for not employing adequate labour at site. |
| 97 | Site clearance shall be done by contractor after finishing work and obtain the signature of occupant as the site clearance has done. The same shall be verified and put up before issue of completion certificate. |
| 98 | All Scarps will be done with mechanical scaper |
| 99 | Mechanical scaper should be deposited in our store at the time of sample approval |