| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Dismantling doors (steel or wood or glass) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres below and as per the site incharge direction. |
| 3 | Dismantling wooden boardings in lining of walls and partitions, including supporting members, stacking etc inlcuding lifting, transport, scaffolding, labour, tolls etc all complete within 50 metres lead : Thickness above 25 mm up to 40 mm sqm. - Wall panelling. |
| 4 | Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 6 | Dismantling tile work in floors and walls laid in cement mortar including stacking material etc inlcuding lifting, transport, labour, tolls etc all complete within 50 metres lead for thickness of tiles 10 mm to 25 mm sqm |
| 7 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 5 in Superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement :4 coarse sand) |
| 8 | Providing & applying 12 mm thick cement plaster in CM 1:4 (1 part of cement: 4 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiselling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andcomplete complying withspecifications and as instructed by the Engineer in charge. |
| 9 | Providing and injecting chemical emulsion for Anti- Termite treatment by creating a chemical barrier around the wall trenches& along the external perimeter of the building, expansion joints if any , surrounding of pipe and conduits etc., using chemical emulsion as per manufacturers instruction, including drilling holes and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole. Cost shall include all material and labour, etc. (Plinth Area at Ground Floor level only shall be measured and paid for). complete as per manufacturers specification. Approved manufacturers : PCI, Godrej, Pidilite or approved equivalent. Stage I: Floor & at junctions of the floor & the wall --Stage II: External Perimeter of the Toilet |
| 10 | Dismantling of existing 2\"x2\" grid false ceiling, gyp board ceiling with necessary support, stacking etc inlcuding lifting, transport, scaffolding, labour, tolls etc all complete within 100 metres leadas per the site incharge direction. |
| 11 | Dismantling of existing 4\" height, 3\" thk veneer partition with necessary support members, stacking etc inlcuding lifting, transport, scaffolding, labour, tolls etc all complete within 100 metres leadas per the site incharge direction. - Half height partition |
| 12 | Dismantling of existing FULL height, 3\" thk veneer partition with necessary support members, stacking etc inlcuding lifting, transport, scaffolding, labour, tolls etc all complete within 100 metres leadas per the site incharge direction. - Full height partition |
| 13 | Dismantling of existing false flooring, stacking etc inlcuding lifting, transport, labour, tolls etc all complete within 100 metres leadas per the site incharge direction. |
| 14 | Dismantling of existing wooden flooring with skirting, stacking etc inlcuding lifting, transport, labour, tolls etc all complete within 100 metres leadas per the site incharge direction. |
| 15 | Dismantling of existing Reception table (granite finish) in usable condition, stacking and transporting the materials from the site to KPL Port, Ennore. (Note: Transportation can be operated as per Item No.1.14) |
| 16 | Dismatling of existing plumbing items like WC & wash including available fixtures, stacking and disposing the unwanted materials from the site. |
| 17 | Disposing of all unservicable items like demoilsed tile, brickworks, concrete and other debris away from the site for a lead of 10 KM as perdirection of Engineer-in-charge mentioned in Item no.1.03, 1.04, 1.05 & 1.15 . (Eicher van/ Equivalent) |
| 18 | FLOORING WORKS |
| 19 | Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily. Laying to be done at various places as specified by the Site incharge.Size of Tile 600 x 1200 mm OR 600X600 mm (Basic cost of Tile - Rs.90) |
| 20 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Laying to be done at various places as specified by the Site incharge. (Basic cost of Tile - Rs.90) |
| 21 | PARTITION WORKS |
| 22 | Providing and fixing 75mm thk Full Height Veneer finished PLYwood Partitions using 25 x 50mm anodised aluminum section framework @ 600 c/c bothways with horizontal noggings at floor and soffit, both side skinning with 12mm thick veneer finished PLYwood. All electrical/network switch boxes, niches to be boxed/packed with adequate reinforcement using PLYwood. The aluminium channel to be provided at intersection of two materials. The partition may have 6mm thk glass panels at specified areas as per the drawing fixed with veneer finished PLY Jamb lining all around. Note cost to include aluminum frame upto actual ceiling (frame to be anchored to actual ceiling). Complete as per drawing and directions. The veneer should be of teak or equivalent ( Basic cost of veneer - Rs.80)(Measurement will be taken as only for veneer finished area).Both side Veneer finished partition - FULL HEIGHT |
| 23 | FALSE CEILING WORKS |
| 24 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 25 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge with 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 sqm ) |
| 26 | DOORS & WINDOWS |
| 27 | Providing andfixing of 32mm thk Solid core BWP flush door finished with 4mm thk Veneer on both sides and the edge to be finished with first quality Teakwood lipping. The door frame should of 2.5\"x 4\" wide 1st quality teak wood framefinished with necessary polish as per approval.The door shall have vision panel of 6mm thk glass, 4 Nos. S.S. Ball bearing butt hinges, Mortise Handle, Mortise Lock body, 60mm Euro profile cylinder with one side key & one side knob operation & door closure from \"OZONE /APPROVED EQUIVALENT\" as per approval. The veneer should be of teak or equivalent ( Basic cost of veneer - Rs.80).Both side Veneer finished door of size 800 x 2100mm. |
| 28 | Providing andfixing of 32mm thk Solid core BWP flush door finished with 4mm thk Veneer on both sides and the edge to be finished with first quality Teakwood lipping. The door frame should of 2.5\"x 4\" wide 1st quality teak wood framefinished with necessary polish as per approval.The door shall have vision panel of 6mm thk glass, 4 Nos. S.S. Ball bearing butt hinges, Mortise Handle, Mortise Lock body, 60mm Euro profile cylinder with one side key & one side knob operation & door closure from \"OZONE /APPROVED EQUIVALENT\" as per approval. The veneer should be of teak or equivalent ( Basic cost of veneer - Rs.80).One side Veneer & other side laminate finished door of size 800 x 2100mm. |
| 29 | PAINTING WORKS |
| 30 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete |
| 31 | Applying priming coats with primer of approved brand andmanufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 32 | Providing and applying priming coats with primer of approved brand andmanufacture, having low VOC (Volatile Organic Compound ) content with ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre . |
| 33 | Applying priming coat with ready mixed red oxide zinc chromate primer including second coat of approved brand and manufacture on steel galvanised iron/steel works where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete |
| 34 | ApplyingWall & ceiling painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.(Two coats) and where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete |
| 35 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacture and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete |
| 36 | Painting surface with TEXTURED paint of required shade as per manufacturer\"s specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete |
| 37 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface again fine wet rubbed smooth, which is further allowedto dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. - PARITION & DOORS |
| 38 | MISCELLANEOUS |
| 39 | Providing and erection of 12mm thk toughned glass shelves of 15\" deep,5\" length fixed to wooden partition with necessary 2nos. Of L shaped SS brackets and screws with all complete. |
| 40 | Providing and fixing of 3\" Veneer Panelling on windows supported between columns with necessary supportfinished with 4mm thk Veneer & necesssary adhesive and grooves as per the drawings.The veneer should be of teak or equivalent ( Basic cost of veneer - Rs.80) shall be finished with necessary melamine finish of approved shade as per direction of the engineers in charge. |
| 41 | Providing and fixing of Veneer Panelling on columns & walls cladded over 18mm thk PLY finished with 4mm thk Veneer & necesssary adhesive and grooves as per the drawings.The veneer should be of teak or equivalent ( Basic cost of veneer - Rs.80) shall be finished with necessary melamine finish of approved shade as per direction of the engineers in charge. |
| 42 | Providing and fixing of Roller Blinds made of 38mmx38mm aluminium extruded top rail with powder coated finished enabled with control Mechanism to be louvolite and chain must be metal. Stops to be fitted top & bottom to eliminate over-run and it should have straight edge finish. The blinds should be of approved manufactures and complete as per the approved shade and texture. Fixing of blinds at various place to be considered. ( Basic cost Rs 200/-) |
| 43 | Providing and fixing of 4mm thick, 24\" widex 12\" Ht. SS Plate 304 grade with text etched and painted to colourwith necessary SS Hanging from the false ceiling as per approval. - Signage |
| 44 | Providing and fixing of NON-REFLECTIVE SUN CONTROL FILM on existing window glass panes including material, labour, tools, scaffolding etc all complete as per the direction of site incharge. |
| 45 | ELECTRICAL WORKS |
| 46 | WIRING IN STEEL CONDUIT |
| 47 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 48 | Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point (without independentswitch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 49 | Wiring for twin control light point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required |
| 50 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 51 | 2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire |
| 52 | 2 x 2.5 sq. mm + 1 x 2.5 sq mm earth wire |
| 53 | 2 x 4 sq. mm + 1 x 4 sq mm earth wire |
| 54 | 2 x 6 sq. mm + 1 x 6 sq mm earth wire |
| 55 | 4 x 6 sq. mm + 2 x 6 sq. mm earth wire |
| 56 | Supply and Fixing Power plug Point Modular type accessories: Supply and fixing of metal box of GI box with modular plate and cover in front on surface or in recess , including providing and fixing of 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections, painting etc. as required. (For light plugs) and as per technical specification and as per latest IS / IEC |
| 57 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. and as required and as per technical specification and as per latest IS / IEC |
| 58 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 59 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 60 | Supply and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required and as required and as per technical specification and as per latest IS / IECTelephone socket outlet |
| 61 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 62 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 63 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required |
| 64 | 6 Module (200mmX75mm) |
| 65 | 8 Module (125mmX125mm) |
| 66 | Supply and fixing \"C\" Series, SP MCB : Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per technical specification and as per latest IS / IEC |
| 67 | Single pole |
| 68 | Double pole |
| 69 | Supplying and fixing following rating, four pole, (three phaseand neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A |
| 70 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outletwith 2 pole and earth, metal enclosed plug topalongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 71 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 72 | EARTHING |
| 73 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) and as per technical specification and as per latest IS / IEC |
| 74 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required and as per technical specification and as per latest IS / IEC |
| 75 | Supply,Fixing ,testing & commissioning of all type of light Fixtures complete with fixing accessories and mounting bracket,earthing for the fittings all complete as required.(connection from the ceiling rose or junction box to light fixture with terminations).Note : All light fixture with Electronic Ballast with THD <10% |
| 76 | Supplyof fluorescent luminaires with mirror optics, made of CRCA MS sheet epoxy powder Pre-wiredwith electronic ballasts and ms conduit, coated and pre-wired. Rotor holder main connector, etc. is complete, ready for connection.Ultra-pure aluminum reflector with serrated edges for optimal performance on cross louvers made from aluminum. The mirror assembly needs to be removable for relamping from below. Two 40-watt LED tubes are required ( flame Proof Light Fitting ) |
| 77 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 78 | Supply, install, test, and commission a 400mm oscillation fan for official pedestal air circulation.There shall be a three-blade impeller on pedestals and brackets mounted above columns for basement square types only |
| 79 | CABLE TRAYS |
| 80 | Supplying and installing following size of perforated HotDipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 81 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 82 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 83 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 84 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 85 | 3 KVA UPS |
| 86 | Supply,installation,testingandcommissioningofIndependent 3 KVAUPS systemwith 415V Threephaseinputand230Vsinglephaseoutputwithall requiredaccessories&batterybankfor60minsbackupwithcoveredSMF battery and battery rack for all new required loads covered |
| 87 | MISCELLANEOUS |
| 88 | The installation of existing 6/16 amp socket for UPS supply and all the necessary work needed |
| 89 | Rework in existing DB\"s as per the new electrical layout with necessary arrangments required at site. |
| 90 | Removethe existing switchboard (with 6Amps switches and 6Amps sockets) with all necessary requirements. (Existing Switch board ) |
| 91 | Removing of existing 6/16Amp UPS socket, stacking etc inlcuding labour, tools etc all complete within 100 metres leadas per the site incharge direction. |
| 92 | Removing the existing 2 x 6Amps UPS sockets, stacking etc inlcuding labour, tools etc all complete within 100 metres leadas per the site incharge direction. |
| 93 | Removing existing data & voice sockets, stacking etc inlcuding labour, tools etc all complete within 100 metres leadas per the site incharge direction. |
| 94 | Removing existing main wiring for lighting load, stacking etc inlcuding labour, tools etc all complete within 100 metres leadas per the site incharge direction. |
| 95 | Removing existing main wiring for Power load, stacking etc inlcuding labour, tools etc all complete within 100 metres leadas per the site incharge direction. |
| 96 | Removing existing Data, voice wiring in all conduits including floor raceways, stacking etc inlcuding labour, tools etc all complete within 100 metres leadas per the site incharge direction. |
| 97 | The removal of existing light fittings with 2 x 36 watts stacking etc inlcuding labour, tools etc all complete within 100 metres leadas per the site incharge direction. |
| 98 | Loading,Transporting & unloading of all usable stacked materials like wires, switches, switch plate, etc as mentioned in Item no. 18.3 to 18.10) from the site to KPL Port, Ennore at the specified place as per the direction of site incharge. |
| 99 | NETWORK SYSTEM |
| 100 | Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required |
| 101 | 20 mm |
| 102 | 25 mm |
| 103 | 32 mm |
| 104 | Supply, install, connect, and commission 2.0mm thick cat-6 UTP cables with four pairs.Use the following instructions to transmit DATA through the above PVC pipes / Raceways to an RJ-45 socket... Network Switch to RJ-45 socket. To obtain data |
| 105 | Supply and Modular RJ11 telephone outlet with shutter,back box on wall /partition |
| 106 | Suplly and Installation of One no of RJ-45 I/O with face plate and Back Box |
| 107 | Supply and Instalaation of One no of RJ-45 and One no of RJ-11 with Dual Face plate and Back Box |
| 108 | Supply erection, connecting & commissioning of 9U rack. |
| 109 | Supplying, Erecting, connecting & commissioning of 24 Port Patch panel Loaded. |
| 110 | Supplying, Erecting, connecting & commissioning of 1 Mtr Patch card |
| 111 | Supplying, Erecting, connecting & commissioning of 24 Port GigabyteSwitch |
| 112 | Supply and laying 10 pair krone connector housed in heavy duty ABS plastic mould with suitable locking arrangements. |
| 113 | Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor,unarmoured telephone cable in the existing surface /recessed steel/PVC conduit as required.10 Pair cable |
| 114 | Removal and Reinstallation of Existing Network Rack Cable Management Patch panel Managed Switches and un Managed Switches With accessories of the Switch as required….. |
| 115 | CCTV WORKS |
| 116 | Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required |
| 117 | 20 mm |
| 118 | 25 mm |
| 119 | 32 mm |
| 120 | Supplying, Erecting, connecting & commissioning of cat-6 cable for CCTV |
| 121 | Supplying and Installation of24Port POE Switch Unmanaged |
| 122 | Supplying and installation of 24 port jack panel. |
| 123 | Supply and installation of 9U closed rack. |
| 124 | Supply and fixing 1 metre mounting cord (Systimax). |
| 125 | Supply and fixing RJ45 Connectors (Metal Connector) |
| 126 | Supply and fixingof CP Plus/Secureye / D-Link make IP night visionbullet/dome camera 20 mt2 Mega Pixel HD Camera |
| 127 | Supply and fixingof CP Plus/Secureye / D-Link 32 Channel HD Recording NVR with necessary required job etc... |
| 128 | Supply and fixingof CP Plus/Secureye / D-Link 8 Channel HD Recording NVR with necessary required job etc... |
| 129 | Supply and fixingof CP Plus/Secureye / D-Link 4TB HDD for Recording |
| 130 | MONITOR FOR CCTV Supply, installation, testing & commissioning of Client Workstation computer with Video management software as per following specifications:Intel® Core™ Intel Core i7-8700, 3.2 GHz, OS - Genuine Microsoft Windows® 10 Enterprise 64-bit, RAM - 16GB, Hard Drives - 2TB, 7200RPM SATA3, Video Adaptor - Integrated Intel UHD graphics 630 supporting 2 Monitors over HDMI/VGA, Network Connection - 1 Gbit/sec or greater, Two(2) PCI-Express Expansion Slots 2/4 USB, CD/DVD ROM, 32\" HDMI Monitor, USB Keyboard and Mouse, UPS, associated cables etc |
| 131 | Supply,installation,testingandcommissioningofIndependent1 KVAUPS systemwith 415V Threephaseinputand230Vsinglephaseoutputwithall requiredaccessories&batterybankfor60minsbackupwithcoveredSMF battery and battery rack for all new required loads covered |
| 132 | Supply, Installation, testing and commissioning of LED TV 32\" SIZE : 32 INCH (101.6CM),4k UHD Smart TV , 2HDMI port , 2USB port , LAN port , wifi connectivity , Wallmount Stand , with remote and other required accessorie |
| 133 | FIRE DETECTION AND ALARM SYSTEM |
| 134 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 135 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required |
| 136 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required |
| 137 | Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 138 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 139 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required |
| 140 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required |
| 141 | Supply, installation, testing and commissioning ofMicro Processor based conventional 4 Zone Fire AlarmControl Panel having the rating of 24 volt DC powersupply, consisting 230 / 24 volt SMPS unit, 2 Nos. of12 volt 7 AH standby batteries, suitably mounted onwall using fixing accessories like screws, plug, clampsand etc., as per standard methods and as directed bythe Departmental Officers. |
| 142 | CABLING WORKSSupplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 143 | The removal of the existing smoke detector with built-in LED and its mounting base along with each connection as necessary. |
| 144 | Installation, testing, and commissioning of smoke detector with built-in LED, mounting base, all connections, etc. |
| 145 | HVAC WORKS |
| 146 | Supply and laying of 5/8\" and 3/8\" copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 147 | Supply and fixing of MS stand for fixing outdoor unit |
| 148 | Supply and fixing of water drain pipe line(1” PVC Pipe) |
| 149 | Supply and providing of pipeline nitrle rubber insulationfor Refrigerant and drain pipe lines. |
| 150 | The removal and reinstallation of the existing high walt split ac unit(1.0 TR, 1.5TR, 2.0 TR ), along with preparation for drain pipe installation, as well as the installation of a suitable stabilizer. Including gas re-filling, including transportation charge, as determined by site engineers, and all necessary work as determined by site conditions. |
| 151 | The removal of high wall split type air conditioning units, 1.0 TR 1.5TR, 2.0TR, with stabilizer, exterior unit, copper pipe drain pipe, internal cable wire along with any needless requirement work from the site, including taking away etc. according to instructions from the site in charge. |
| 152 | Removing of Copper pipes and refixing with nitrile rubber insulation as required, etc. |
| 153 | Copper pipe removal with necessary job requirements, etc. |
| 154 | Drain Water PVCpipe removal with necessary job requirements, etc. |
| 155 | BUYBACK OF DISMANTLED AND STACKED ITEMS |
| 156 | Buyback of all stacked materials mentioned in Item no.1.01, 1.02, 1.09, 1.10, 1.11, 1.12, 1.13 etc., and any other items as directed by the KPL Engineer In Charge, inlcuding lifting, transport, labour, tolls etc all complete from the site as per thesite incharge direction. |