Special Repair To Bldg No. T-39 And Special Repair To Road Furniture Item At Mil Cantt Ajmer Under Ge Nasirabad. Special Repair To Bldg No. T-39 And Special Repair To Road Furniture Item- Taking Down Cement Or Cement Lime Plaster On Stone / Brick Wall, Ceiling Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc Complete All As Specified And Directed. 2 M& L For 15 Mm Thickrendering In Cement Mortar ( 1:6 ) , On Stone Masonary Surfaces Finished Even And Smooth, Complete All As Specified And Directed 3 M&L For Rendering 15Mm Thick In Cm 1:4 On Stone Masonry, External Surfaces Finished Even And Smooth, Complete All As Specified And Directed 4 M & L Forpreparation Ofnew Plastered Surfaces Of Wallsand Providing Two Coat Of Cement Base Paint Over A Coat Of Primer, Complete All As Specified And Directed. 5 M & L Forpreparation Old Decorated Surfaces Of Wallsand Providing One Coat Of Cement Base Paint Complete All As Specified And Directed. 6 M & L For Complete Removal Of Existing Treatment Andpreparationwall Surfaces And Applying Two Coats Of Oil Bounddistemperover A Coat Of Primer Over 1 Mm Thick Wall Care Of Putty Complete All As Specified And Directed 7 M&L For Preparation Of New Plastered Surfaces And Applying Two Coats Of Oil Bounddistemperover A Coat Of Primer Over 1 Mm Thick Wall Care Of Putty Complete All As Specified And Directed. 8 M&L For Preparation Of Old Wooden Surfaces Of Any Descriptionover 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 9 M&L For Preparation Of Old Concretesurfaces Of Any Descriptionover 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 10 S & F Second Class Hw 35Mm Thick, Factory Made, Plain Framed, Paneled Shutter ( Three Panels ) With Panels Of 9Mm Thick Bwpgrade Ply Wood Bonded With High Quality Liquid Phenol Formal Dehyde Synthetic Resin Adhesive Conforming To Is-710. The Size Of Rails & Style Shall Be As Per Is-1003 ( Part-I ) Kiln Seasoned & Chemically Pressure Treated Complete All As Per Specified And Directed. 11 S&F 2Nd Class Hw 35 Mm Thick, Gauged And Skeleton Shutters ( Three Panels ) , Factory Made Open Rebated And Prepare To Receive Glass, Gauge Etc ( With Sash Bar ) , Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut & Mitred Beads For Securing Glass Etc. Size Of Members Of Shutter Shall Be As Specified In Ssr 2009 Part-I, Section 8 Clausemember Shall Be Kiln Seasoned& Chemically Pressure Treated Complete All As Specified And Directed. 12 S&F Steel Window / Ventilator Glazed And Gauged ( Combination ) With Side Hung / Top Hung Shutters Incl Box Type / Projecting Type Hinges, And Steel Peg Stay, Handle & Locking Arrangement And Frame Made Out Of 1.25Mm Thick Pressed Steel Frame Complete Incl Necessary Ac / Cooler Arrangement In Window & Guard Barscomplete All As As Specified And Directed. Note : Wire Mesh And Sheet Glass Shall Be Measured & Paid Separately Under Respective Items. 13 S & F Aluminium Handle Fabricatedtype, Anodised 150Mm Size Conforming To Is Complete All As Specified And Directed. 14 S & F 300Mm Long Aluminium Alloy, Anodised, Sliding Door Bolts With Hasps, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy And Fixed Complete All Asspecified Anddirected. 15 S&F Aluminium, Anodised, Barrel Tower Bolt Of Extruded Section, Isi Marked, 150 Mm Long Complete All As Specified And Directed. 16 S&F Mild Steel Butt Hinges, Medium Weight, Cold Rolled, Isi Marked Of Size 100 Mm, Complete All As Specified And Directed. 17 M & L For Rolled Mild Steel Work Angle Ironas In Door Frame ( Chowkhats ) Of Frame Confirming To Fe-290 Or Fe-330 Including Complete All As Specified And Directed. 18 Taking Down Chowkhats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Exc 1.50 Sqm And N.Exc 4.00 Sqm Each And Removing From Site Complete And Making Good Disturbed Surfaces Of Wall In Cm ( 1:3 ) All As Specified And Directed. 19 Taking Down Unserviceable Chowkhats Or Frame With Shutters ( Without Taking Off Shuters From The Frames ) Of Any Description N Exc 1.50Sqm And Removing From Site And Making Good Disturbed Surfaces Of Wall In Cm 1:3 Complete All As Specified & Directed. 20 M & L For Preparation Of New Wooden Surface Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Of Ist Quality Over A Coat Of Pink Primer Complete All As Specified And Directed. 21 M&L For Preparation Of New Steel Surface Over 10Cm Width Or Grith & Applying Two Coats Of Synthetic Enamel Paint Of 1St Quality Over A Coat Of Red Oxide Primer Complete All As Spd & Directed. 22 S&F Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire & Average Width Ofaperture 1.40Mm & Fixed With Wire Staples Complete All As Spd & Directed. 23 S&F 3.00 Mm Thick Sheet Glass, Ordinary Quality & Glazing With Oil Putty Not Exc0.50 Sqm Each Pane Complete All As Spd & Directed. 24 S&F In Repair Road Stud ( Cat Eye ) Abs Bodyconforming To Irc 67-1977Giving Reflection On Both Sides Including Fixing With Epoxycomplete All As Specified And Directed. 25 S&F In Repair Solar Road Studs Made Up Of Highly Compressive Materials , Water Resistant Alluminium Alloy And Polycarbonates 122 X 122X 20Mm With 6 Ledprismatic Reflective Lens On Each Side With Stemfixed Inroadcomplete All As Specified And Directed By Engineer-In-Charge. 26 M&L For 2-3 Mm Thick And 100 Mm Wide Thermo Plastic Reflective Painting White Or Golden Yellow All As Specified As On Road Surfaces In Marking Speed Breakers, Centre Line, Edge Line Etc Complete All As Specified And Directed. 27 Exavating In Post Holes ( Or Similar Holes ) Each N.Exc 0.5 Cum Getting Out In Soft / Lose Soil Returning, Filling In And Ramming Earth In Layers N.Exc 25Cm, Watering And Removing Surplus Soil To A Distance N.Exc 50M And Making Good Surfaces Complete All As Specified And Directed. 28 M&L For Pcc 1:3:6 Type C-2 Using 40Mm Graded Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And Directed. 29 M&L For 1.65Mm Thick & 50 Mm Bore ( Outer Dia 60.3Mm ) Stainless Steel Pipe Of Schedule 5 S Sign Board Complete All As Specified And Directed. 30 S&F Informatory Sign Board In Reqd Size And Each Sign Board Made Of Two 4Mm Thick Aluminium Composite Panel ( Acp ) , Both Side Face To Fully Covered With 3M Scotchlite Brand High Intersity Prismatic Grade Retro-Reflective Sheet Shall Be Astm D 4956 Type Iv In Required Colour.The Retro-Reflective Sheet Shall Be Processed On Acp By 3M Equipment Heat Lamp Vacum Applicaror And Letter, Signs And Symbol Shall Be Cut By Computerized Plotter Or Digital Printed On Retro-Reflective Sheet With High Quality Eco-Solvent Digital Roland And Fabricated Out Of High Internsity Prismatic Grade Sheeting With Text Matter ( As Reqd ) And Border Of Same Sheeting.Signboard Shall Be Supplied Along With Supported Circular Hollow Stainless Steel Section Frame Of Size 25Mmx25mmx1.29Mm Thick Along With Proper Clamping With Same Section Of Stainless Steel And Nut Bolts / Welding, Complete All As Specified And Directed. 31 S&F Guide Post Delinators Model No. 952 Gp Abs Round Body Fitted With 2 Nos 100 Mm Dia Highly Reflective Reflectors Made Out Of Pmma And Mounted On Ms Pipe Of 50 Duly Powder Coated, Anti Rust & Anti Theft Steel Net Make ( Dark Eye ) Complete Fixing Incl Necessary Excavation, Pcc Etc Required Complete All As Specified And As Directed By The Engineer-In-Charge. 32 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, Including Fittings Such As Switches, Ceiling Roses, Holders, Regulators, Sockets Etc., Removing Materials From Siteand Making Good Disturbed Surface Of Walls, Floors Etc Complete All As Specified And As Directed By The Engineer-In-Charge. 33 Disconnecting Unserviceable Sub Main Wiring / Service Connection Of Any Size And Including Steel Conduit And Accessories And Removing From Site And Making Good The Disturbed Surfaces Complete All As Specified And As Directed By The Engineer-In-Charge. 34 Taking Downmcb DbS Complete With McbS / Isolator Etc Removing Materials From Siteand Making Good Disturbed Surface Of Walls, Floors Etc Complete All As Specified And As Directed By The Engineer-In-Charge. 35 M&L For Point Wiring With 1.5 Sqmm, Pvc Insulated, Unsheathed, Stranded Copper Conductor Single Core Frls Cable, Is-694 Marked, Drawn Through And Including Non Metallic Rigid Pvc Concealed Conduit 20Mm Dia Or Higher Complete With All Pvc Conduit Accessories Such As Socket, Elbow, Junction Box, Bell Mouth, Reducer, Bend And Flexible Conduit Etc. / Fittings Isi Marked And Sunk Type Pressed Steel Anodised Terminal Box 1.2 Mm Thick With Bakelite Laminated Sheet Top Cover 3 Mm Thick, Brass Screws And Cup Washers Including 1.5 Sqmm Stranded Copper Conductor Pvc Insulated Green In Colour As Continous Earth Conductor Connected To Common Earth And Earth Dolly With All Accessories For:- 36 One Light Point Controlled By One, One Way Switch. 37 One Ceiling Fan / Exhaust Fan Point Controlled By One, One Way Switch. 38 One Three Pin 5 Amp Socket On Same Board With Other Switches. 39 One 3 Pin 5 Amp Socket On Independent Board. 40 All As Per Item No. 35.00 Here-In-Before But With 2.5 Sqmm, For One 5 Pin 5 / 15 Amp Socket On Independent Board Including 2.5 Sqmmstranded Copper Conductor ( Frls ) Pvc Insulated Green In Colour As Continous Earth Conductor Connected To Common Earth Complete All As Specified And As Directed By The Engineer-In-Charge. 41 S&F Of Submain Wiring With Two Runs Of Single Core Pvc Insulated And Unsheathed Multistranded ( Frls ) Copperconductor Cable Of Size 6.00 Sqmm Lt, 1100 Volts Grade, Drawn Through And Including 25 Mm Dia Or Higher Pvc Nonmetallic Concealed Conduit With Accessories Such As Socket, Elbow, Junction Box, Bell Mouth, Reducer, Bend And Flexible Conduit Etc. And Fittings And One Run Of 6 Sqmm Single Core Multistrandedcopper Conductor Cable Green Colour As Earth Continuity Conductor Complete All As Specified And As Directed By The Engineer-In-Charge. 42 S&F Switch Piano Flush Type 5 Amps, Single Pole One Way 240 Volts Complete All As Specified And As Directed By The Engineer-In-Charge. 43 S&F Switch Piano Flush Type 15 Amps, Single Pole One Way 240 Volts Complete All As Specified And As Directed By The Engineer-In-Charge. 44 S&Fsocket Outlet 3 Pin 5 / 6 Ampflush Type Complete All As Specified And As Directed By The Engineer-In-Charge. 45 S&Fsocket Out Let 2 In 1, Multipurpose 3 Pin 15 / 16 Amp Flush Type Isi Marked Complete All As Specified And As Directed By The Engineer-In-Charge. 46 S&F Ceiling Fan Regulator Electronic Flush , Steped ( Four Step ) 230 Volts Ac Complete All As Specified And As Directed By The Engineer-In-Charge. 47 S&F Ceiling Rose Surface Bakelite 3 Terminals 63.5 X 17 Mm Complete All As Specified And As Directed By The Engineer-In-Charge. 48 S&F Of Lamp Holder Pvc / Polycarbonate Type With Back Plate Complete All As Specified And As Directed By The Engineer-In-Charge. 49 S&F Led Tube Light Fitting In Acrylic Linear Tube ( 1X 18 Watt ) , 230V For Single Led Tube Lightincluding 1 X 18 W Ledretrofitbar Professional Cw 6500 K Cover Channel, Bipin Holders, Led Power Driver, Connector Block, Etc Complete With All Accessories Internally Prewired And Including Connecting Up With Three Core Flexible Copper Conductor Cable With Suitable Size For Connection Of Fitting From Ceiling Rose Complete All As Specified And Directed. Make :-Havells Cat Part No Photonultra2.01212T8sstl20wled 865Spc ( For Tube ) Regalbattent8upto1x22wdsbswh ( For Batten ) Bajaj Cat Part No Blrb 18W Cwc For Tube , Blrb - Db 118 For Batten , Or Equivalent Model Of Philips / Crompton 50 Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed.Make :- Bajaj / Havells / Cg 51 S & F Led Light Fitting 1X10wbulkhead Luminaires Including Led Light Driver Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed.Make :- Bajaj / Havells / Cg 52 Supply And Fixing Testing And Commissioning Energy Saving Street Light Luminaire 35 Watt Led , Pressure Die Cast Housing With Epoxy Powder Coated With Colour Finish And Prismatic Poly Carbonate Coverlic Cover Complete, Ip 66 Protection Incl Connecting With Three Core Copper Flexible Wire From Ceiling Rose To Connector Of Light Fitting Complete All As Specified And Directed By Engr-In-Charge. Make- Havells Cat Part No Enduracityliteplat Plussl35wled757sasybopc Or Equivalent Model Ofsurya / Control& Switchgear / Bajaj 53 Supply And Fixingstreet Light Bracket Made Of 32 Mm Gi Pipe , 1.2 Mtr Lenght Fixed Withtwo Nos Of Clamp , Nut And Bolts For Fixing Of Street Lightcomplete All As Specified And Directed By Engr-In-Charge. 54 S & F Of Mcb Sp, 240 Volt, 6 Amp To 40 Amp Capacity, 10 Ka, C Curve Complete All As Specified And Directed. 55 S & F Of Mcb Spn, 240 Volt, 63 Amp Capacity, 10 Ka, C Curve Complete All As Specified And Directed. 56 S&F Of Mcb Distribution Board Single Pole & Neutral With 200 Amps Rated Bus Bar, Double Door Ip-43 DbS , Made Outof Sheet Steel Enclosure, Recessed Type, Factory Made Powder Coated 8 Way, 240 Volts Suitable For Housing McbS Including Blanking Platecomplete All As Specified And As Directed By The Engineer-In-Charge. 57 S&F Exhaust Fans Ac Single Phase 230V Of Size 300Mm Sweep With Louver Including Connecting With Three Core Flexible Copper Wire From Ceiling Rose To Connector Of Fan Complete All As Specified And Directed.Make :- Usha / Crompton / Bajaj 58 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6 Mm Thick Buried Directly In Ground Vertically To A Depth Not Less Than 2.25M Below Ground Level With Top Edge Of The Earth Plate At A Depth Not Less Than 1.5M Below Ground Level, Connected To Galvanised Earth Lead Wire 4.00 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel And Other End Of Earth Wire Connected To Main Switch Board And Protected By Galvanised Iron Pipe Light Grade 15Mm Bore And Water Pipe 20 Mm Bore Gi Med Grade With Funnel And Wire Mesh Pcc Chamber In Cement Concrete 1:3:6 Type C-2 And Rcc Cover With Handle All As Specified And Shown In Elect Plate No 3 Of Ssr Part-I Of 2009 Incl Dismantling Of Old Unserviceable Existing Earthing Complete All As Specified And As Directed By The Engineer-In-Charge. 59 S&F Of Led Lamp 9 / 10 Watt Complete All As Specified And As Directed. Make :- Havells / Crompton / Bajaj / Usha 60 Supply & Fixing Ceiling Fan 1200 Mm Sweep , 230 Volts, Ac , 50 Hz, Copper Winded Motor, Bee 5 Star Rated White Colour Complete With Motor, Blade Set Of Three Nos , Down Rod, Canopy, Shackle Assy Complete All As Specified And As Directed.Make: Crompton / Havells / Orient 61 S&F Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Earth Plug And Socket Complete With One Single Pole 20 Amp Mcb Sp C Series For Ac Complete All As Specified And Directed. 62 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 16 Sq Mm 4 Core Complete All As Specified And As Directed By The Engineer-In-Charge. 63 Supply And Fixingtubes Light Grade Gi Tubing 40 Mm Dia Withall Fitting Laid In Trenches, Fixed On Pole / On Wall For Cable Protection Complete All As Specified And As Directed By The Engineer-In-Charge. 64 Excavating In Trenches Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Or For Cable Laying Or Not Exceeding 10 Sqm On Plan And Not Exceeding 1.5 M In Depth And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed. 65 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm In Soft / Loose / Hard / Dense Soil Complete All As Specified And As Directed. 66 Removing Excavated Material ( Soils ) Not Exceeding 50 M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point 67 Supply & Spreading In Trenches Dry River Sand Cushioning To Underground Cable In Trenches Including Spreading, Levelling Hand Punning Down Complete All As Specified And Directed.Note:- Depth Of Sand Cushioning Will Be Measured After Punning Down And Levelling The Sand Properly. 68 M&L For Laying Of Bricks Locally Available Sub Class B Bricks, Non-Modular Sizes As Per Is 1077: 1992 For Cable Protection Cover Laid Flat And Dry In Trenches Over The Cable Perpendicular To The Direction Of Cable All As Directed. 69 Total In Figures 70 Quoted Amount In Words