Engineering, Procurement, Supply, Installation, Testing And Commissioning Of Cgmp Centre Of Cellular Immunotherapies At Actrec On Turnkey Basis , Cat ( A ) -Turnkey Works Required Forengineering, Procurement, Supply, Installation, Testing & Commissioning Of Cgmp Centre Of Cellular Immunotherapies At Actrec On Turnkey Basis , Civil Work , Supply And Installation Of Double Skin Modular Wall Panels Made Of 0.8Mm Thick Gi Powder Coated Sheets On Both Sideswith Puf Of Density 40±2Kg / M³as Infill, Gi Profiles For Reinforcement Along The Periphery, Floor Track Suitable To Accommodate The Epoxy Floor Flush With Wall Panel. Joint Shall Be Sealed With Cleanroom Compatible Silicon Sealant. The Thickness Of Panel Shall 80Mm With Riser Panel Arrangement ( Including Prefilter, Damper & Riser Grill - All Clean Room Compliant ) Wherever Required As Per The Instruction Of Engineer In Charge And As Per Approved Drawing. The Panels Should Certified For Use In Clean Room Facility With 60 Minutes Fire Resistance Certification. Including Providing And Fixing Of Pvc Conduit 32 Mm In The Wall Panels And Factory Made Cut-Outs Concealed In Wall Panel For Electrical Sockets, Switch Boards, Mgs, Etc. , Supply And Installation Of Double Skin Modular Wall Panels Made Of 0.8Mm Thick Gi Powder Coated Sheets On Both Sideswith Puf Of Density 40±2Kg / M³as Infill, Gi Profiles For Reinforcement Along The Periphery, Floor Track Suitable To Accommodate The Epoxy Floor Flush With Wall Panel. Joint Shall Be Sealed With Cleanroom Compatible Silicon Sealant. The Thickness Of Panel Shall 50Mm With Riser Panel Arrangement Wherever Required As Per The Instruction Of Engineer In Charge And As Per Approved Drawing. The Panels Should Certified For Use In Clean Room Facility With 60 Minutes Fire Resistance Certification. Including Providing And Fixing Of Pvc Conduit 32 Mm In The Wall Panels And Factory Made Cut-Outs Concealed In Wall Panel For Electrical Sockets, Switch Boards, Mgs, Etc. , Supply And Installation Of Double Skin Totally Flush Walkable False Ceiling Made Of 0.8Mm Thick Powder Coated Sheets On Both Sides Withpuf Of Density 40 ± 2 Kg / M³ As Infill, Gi Profiles For Reinforcement Along The Periphery, Including Ceiling Gridfor Easy Installation And Necessary Hardware. Joints Shall Be Sealed With Cleanroom Compatible Silicon Sealant. ( Load Bearing Capacity- 150 Kg / M2 ) The Thickness Of Panel Shall 50Mm As Per The Instruction Of Engineer In Charge And As Per Approved Drawing. The Panels Should Certified For Use In Clean Room Facility With 60 Minutes Fire Resistance Certification. Factory Made Cut-Out To Be Made In The Ceiling Panel Forlight Fixture & Supply & Return Air Grills / Hepa Boxes In The Ceiling Panel , Supply And Installation Of Extruded Aluminium Powder Coated / Anodized Clip On Type Covings For The Entire Wall To Ceiling, Wall To Wall, Wall To Floor.- Curvature Radius : R-70 Type. Joint To Be Sealed With Cleanroom Compatible Sealant. , Supply And Installation Of Extruded Aluminium Powder Coated / Anodized Clip On Type Covings For The Entire Wall To Ceiling, Wall To Wall, Wall To Floor.3D Internal / External Corner Coves. Joint To Be Sealed With Cleanroom Compatible Sealant. , Providing And Fixing Flush Doors 35Mm Thick With 1.0 Mm Laminates On Both Sides. The Item Includes Teakwood Chaukhat ( Frame ) Made From 75X50 Teakwood. The Door To Have 12Mm Teak Wood Lipping On Edges. The Door Is To Be Complete With Cylindrical Door Lock , 200Mm Ss / Brass Handles, Tower Bolts, 119Mm Brass / Ss Hinges, Ss Door Stopper With Double Rubber Stopper And Necessary Screws Etc. All Teakwood Surfaces To Be Malamine Polished Complete To The Satisfaction Of Architect / Employer. Cost To Include All Edgings And Vision Panel Of Size 250Mm*150Mm. , Supply And Installation Of Extruded Aluminium Powder Coated / Anodized Clip On Type Covings For The Entire Wall To Ceiling, Wall To Wall, Wall To Floor. Coving In Epoxy Screed For Wall To Floor. Joint To Be Sealed With Cleanroom Compatible Sealant. , Supply And Installation Of 46 Mm Thick Doors Made With Pu Painted 0.8Mm Thick Gpsp Sheets On Both Sides With Puf As Infill, 1.2 Mm Thick Gpsp Powder Coated Door Frames, Hardware Like Ss Push Plate, Ss D Handle On Both Sides, Ss Ball Bearing Butt Hinges, Stainless Steel Push Plates On Push Side. - Ss 304 ( With Engraving ) , Double Glazed View Panel Of Std.Size , Dorma Ts-71 Std.Arm Door Closure For Active Leaf, Concealed Flush Bolt For Double Door And Provision For Automatic Bottom Drop Seal, Stainless Steel Kick Plates Ss 304 Etc. Item Includes Cost Of Supply And Installation Of All Accessories And Fixtures As Mentioned Above Excluding Door Interlock And Door Access Control And Should Be Clean Room Compliant Fixtures. Alongwith Provision Of Toughened Vision Glass / View Panel With 30Mm Thick Border And Silicon Sealant If Required Flushed With Door And Automatic Door Bottom Seal. , Supply And Installation Of 46 Mm Thick Emergency Doors Made With Fire Retardant Paint Having Fire Protective Certification For 120Mintues For Door Along With Suitable Infill To Resist Temperature Upto 600-700 Degree , Alongwith 1.2 Mm Thick Gpsp Powder Coated Door Frames, Hardware Like Ss Push Plate, Ss D Handle On Both Sides, Ss Ball Bearing Butt Hinges, Stainless Steel Push Plates On Push Side. - Ss 304 ( With Engraving ) , Double Glazed View Panel Of Std.Size , Dorma Ts-71 Std.Arm Door Closure For Active Leaf, Concealed Flush Bolt For Double Door And Provision For Automatic Bottom Drop Seal, Stainless Steel Kick Plates Ss 304 Etc. Item Includes Cost Of Supply And Installation Of All Accessories And Fixtures As Mentioned Above Excluding Door Interlock And Door Access Control And Should Be Clean Room Compliant Fixtures.Alongwith Provision Of Toughened Vision Glass / View Panel With 30Mm Thick Border And Silicon Sealant If Required Flushed With Door And Automatic Door Bottom Seal. , Demolishing Existing Brick Masonry And Tiles With Cement Mortar And Plaster At All Floors And Levels Including Scaffolding Stacking Of Serviceable Materials Without Damaging The Adjacent Masonry / Rcc Structure Sanitary Fittings & Fixtures And Disposal Of Unserviceable Material Carting Away The Debris Out Of Hospital Premises And Scope Also Include Dismantling And Careful Removal Of Doors, Distribution Panel And Storing And Stacking Complete All As Directed By The Engineer-In-Charge. ( Existing Toilets, Guard Room & Record Room & Ground Floor & All Areas Wherever Required For Converting Ward To Cgmp Facility ) . The Scope Also Includes Cleaning Of Flooring And Scraping, Levelling For Application Of Self Levelling Epoxy Coat For Flooring. , Dismantling Of Wash Basin And Removing Of Wall Tiles And All The Allied Stonework And Pipes & Fittings Wherever Necessary And Disposal Of Unserviceable Material Carting Away The Debris Out Of Hospital Premises Or Handing Over The Same To Engineer-In Charge , Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle Size 600Mm Center To Center, Lock And Stopper Etc. Included In The Item Rate ) .As Approved By Engineer Incharge. , Providing And Fixing Panic Bar / Latch ( Double Point ) Fitted With A Single Body, Trim Latch & Lock On Back Side Of The Panic Latch Of Reputed Brand And Manufacture To Be Approved By The Engineer- In- Charge, All Complete. , Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross “T” Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main “T” At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge.Gi Metal Ceiling Lay In Plain Tegular Edge Global White Colour Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of Aluminium Sheet Having Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending. , Providing And Applying 3Mm To 4 Mm Thick Self Levelling Epoxy Flooring System Which Consist Of Surface Preparation, By Grinding The Surface , Minor Repairs If Any, Applying 1Coat Of Epoxy Primer , Laying Self Levelling Epoxy Screed Followed By Top Coat Of Self Levelling Epoxy Coat As Per Manufacturer Specification , Work Inclusive Of Existing Flooring Reparing And Wall Crack Filling Complete Job As Directed By Eic. , Applying 1-2Mm Thick Birla White Wall Putty Followed By Final Coat Of Epoxy Wall Painting Wherever Required As Per The Instruction Of Engineer Incharge. , Providing And Applying And Levelling The Existing Surface With Birla White Cement Based / Coloured Waterproof Putti Of Average Thickness Of 2 Mm Of Approved Thickness, Brand And Manufacture, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Ready For Painting Purpose Etc Complete ( Rate Inclusive Of Scaffolding Matetrial, Labour Charges ) Etc. , Providing And Applyingacrylic ( Premium ) Emulsion Paint Of Approvedmakeandshadeonwallswithsand Papering& Cleaning The Surface, Applying One Coat Of Primer And Lambi / Puttytofullsurface3times, Thereafterpaintingthe Surfaceintwo Coatsoverbaseprimercoattoachieveeven Finish. Rate Is Inclusive Of All Double Scaffolding, All Material And Cleaning As Per Manufactures Standard Application Method & Specification Etc. Complete. , Extra Cost For Projected Return Air Riser Panel Made Of 0.8Mm Thick Powder Coated Sheets With 150Mm Projection Above The Ceiling And Flange For Fixing Duct, With Provision For Fixing Ra Grill And Filter Etc. , Gipc Perforated Grill For Return Air Riser Grill Of 1.2Mm Thick With Capsulation Perforations For Return With All Necessary Fixing Arrangements. , Supply And Installation Of 10 Micron Pre-Filter For Return Air Riser ( 1000 X 500 Mm ) As Per The Instruction Of Engineer In Charge. , Factory Made Cutout In The Ceiling Panel Forlight Fixture & Supply & Return Air Grills / Hepa Boxes In The Ceiling Panel , Providing And Fixing Of Pvc Conduit 32 Mm In The Wall Panels , Factory Made Cut-Outs With Concealed In Wall Panel For Electrical Sockets, Switch Boards, Mgs, Etc. , Providing & Laying Poly Vinyl Chloride ( Pvc ) Rolls Flooringmanufactured Of Approved Make And Approved Pattern For Flooring, Skirting / Dadolaid On Existing Cement Tile Or Concrete Of Plastered Floor Finish With Suitable Adhesive As Per Manufacturers Specifications Closejointed And Finished To Proper Bends, Slopes And Plumbs Asdirected Etc. Complete Generally As Per Manufacturer’S Specifications. Providing & Laying New2mm Thck Pvc Flooring Tiles. , Toughened Lacquered Glass Panelling: Providing And Fixing Of 6Mm Thick Toughened Glass ( Premium Griha Rated Lacquered Glass From Glass Manufacturer ) Of Approved Colour By Doit&C, Mounted On Clip ( J / J1 / I Type ) Or Equivalent On A Perfectly Levelled Surface ( Granite Cladded Pedestal ) . Lacquered Strong Glass Must Be Made Industrially ( Via Curtain Coating Process ) ; Opaque ( If Viewed Against A Support Wall ) , Coated With Pu Lacquer ( 100 Micron Thick ) ; Colour Consistency ( Measured By Spectrophotometer Cm5081 ) ; Highly Durable ( Passes Persoz Hardness Test For Minimum 220 Oscillations ) ; Humid Resistant ( Conforms To Bs En 1036 1999 ) ; Environmentally Friendly ( No Lead, No Arsenic, No Copper, No Formaldehyde ) ; Appropriate Recycled Content ( 12% Post Industrial / 6% Post Consumer ) ; Compressive Strength ( 1000 Mpa ) & Tensile Strength ( 40 Mpa ) , Same As Float Glass. Tempering Should Be Done As The En 12150. Glasses Are To Be Fixed With Polymer Clips ( Single Sided J1 & J2 Type, Double Sided I Type ) , White Backing Foam And Grey Impact Absorbing Foam; To Accommodate Upto ± 10Mm Substrate Undulation, And With A Horizontal Load Capacity Of 30Kg / 100Mm And Vertical Pullout Load > 200Kg / 100Mm, Glass Should Be Supported With 1Mm Thick Lip Covering Upto 3Mm Of Glass Surface; Clips Should Be Fixed Using Durable, Non Corrosive, Strong S.S.Screw 45Mm Long. All Wooden Material To Be Used Shall Be Anti-Termite Treated. The Measurement Only For The Portion Covered By Glass To Be Considered. , Granite Cladded Pedestal Made From 200Mm Thick Aac Single Block Masonary Including Providing And Fixing 18Mm Thick Gang Saw Cut Mirror Polished Premoulded And Prepolished ) Machine Cut On The Blockwork With 1:4 Cement Mortar On All Sides. Including Resting Provision For Glass Panelling / Partition. Including All Material, Labour, Machinery Required To Complete The Work As Per The Instruction Of Engineer Incharge. , Dismantling, Breaking And Cutting Of Slab By Mechanical Means I.E By Using Diamond Cutter / Sawing Machine Without Causing Damage To Any Beams And Columns And Lowering The Cut Pieces Of Concrete Using Chain Pulley Block On The Respective Lower Floor Level And Handling The Cut Pieces Including Cutting It In Smaller Pieces And Stacking / Dispose The Debris Inside The Campus As Per The Instruction Of Engineer Incharge. Item Includes Floor Breaking And Dismantling. , Cutting Of Tiles And Removing Mortar For Placement Of Electrical Conduits In The Floor And Then Covering The Cement Grouting Flushed At Floor Level. Including All Material, Labour, Machinery Required To Complete The Work As Per The Instruction Of Engineer Incharge Excluding Cost Of Electrical Conduits. , Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer And Painting, Including Welding, Bolting Fixing With Labour And Material All Complete. , Providing Metal Roofing Sheets Manufactured From Zinc / Aluminum Alloy Colour Coated Fromn High Tensile Steel Minimum Yield Strength 550 Mpa; Total Coated Thickness0.60 Mm. Profile And Colour As Approved By The Architect ; Generally As Per Durashine Brand Marketed By Tata Bluescope Steel Or Equivalent Including Fixing As Per Manufacturers Recommendations And Includingflashings And Accessories Such As Ridges, Corner Flashings, End Flashings And Galvanised Fasteners From Reputedmanufacturers Such As Mark Fasteners. For Correct Levelling And Alignment Of Sheets Height Of Purlin Tops Shall Be Adjusted As Provided In Purlin Connections. Mode Of Measurements: Plain Area In The Inclined Plane Of Sheets Shall Be Measured. Nothing Extra Shall Be Added For Collugations, Profile, Side Laps, End Laps Etc. , Supply And Installation Of Double Glazed View Panels Embedded In The Clean Room Wall Partitions With Flush Design Fixed With 6Mm Thick Toughened Glass And Necessary Accessories. , Window Modification As Per The Instruction Of Engineer Incharge. , Dismantling Of Existing Fire Fighting System As Per The Instructoin Of Engineer Incharge , Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Challis, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note:- ( 1 ) The Elevational Area Of The Scaffolding Shall Be Measured For Payment Purpose. ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items For Such Works. , Providing And Laying In Position Ready Mixed M15 Grade Plain Cement Concrete, With Cement Content As Per Approved Design Mix And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Plain Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying And Curing, Including The Cost Of Centering, Scaffolding, Shuttering And Finishing, Including Cost Of Curing, Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate / Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineerin-Charge. ( M15 Grade At All Locations Upto Plinth Level ) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Cement Content As Per Approved Design Mix, And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying, Including The Cost Of Centering, Scaffolding, Shuttering, Finishing, Including Cost Of Admixturesin Recommended Proportions As Per Is : 9103 To Accelerate / Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability And Including Supply And Installation Ofpvc Water Stopper As Per Direction Of The Engineer - In - Charge At All Levels. , Providing And Fixing Of Reinforcement Steel Including Material Fabricating, Trasporting, Loading, Unloading, Storing On Raised Steel Rack Platform, Handling, Straightening, Cutting To Length, Bending, Making Hooked Ends, Hoisting Into Place At All Levels And Heights And Binding In Position ( Including Providing & Using 18 Gauge Binding Wire ) Reinforcement Bars Of All Diameters ( Is 1786 , Fe 500 Of All Grade ) To Shape And Size As Per Approved Bar Bending Schedules And Structural Drgs. For All Kinds Of Works At All Heights & Depths As Specified Including Cost Of Approved Quality Pvc / Concrete Cover Blocks, Spacers, Chairs At Regular Interval As Per Relevant Is Code And Such Other Works That Are Required To Make It Complete.Quantity Of Steel As Per Drawing, Approved Bbs And With Authorized Overlaps Only Shall Be Measured And Paid For. Quantity For Chairs And Spacer Bars Will Not Be Paid. The Measurement Shall Be As Per Is 1200 And Reinforcement Hooks And Bends Shall Comply With The Requirement Of Is 2502 Unless Clearly Specified Above. , Aluminum Partition Workproviding & Fixing Alumimium Partitionto The Requiredheight Partly Glazed And Partly Panneledusing Anodized Aluminium Section With Satin Finish Anodizing Of Required Size For Bottom, Top, Middle &Vertical Rails At Required Intervals Panneling With 12Mm Thickboth Side Pre-Laminatd Board Fixed With Sloping Aluminium Beeding Alround With Neoprine Gasket Glazing With 5.5Mm Plain Glass Of Approved Make Fixed Withalumimium Channel Beeding Two Way Pvc Lining / Rubber Gasket To Ensure Water Tightness And Including Providing Necessary Cover Mould Using Suitable Alumimium Section So As To Take Care Of Gaps Between The Walls / Ceiling / Flooring And Partitions Etc. Including Providing And Fixing Necessary Fittings As Specified And Directed. , Aluminum Sliding Door Providing And Fixing Sliding Door To Consist Of Partly Glazed And Partly Panneled With Using 5.5Mm Thick Glass Sheet Of Approved Make And Quality Plain Glass Of Approved Make Fixed With Anodized Aluminium Sloping Channel Beeding With Two Way Pvc Lining / Rubber Gasket To Ensure Water Tightness And Panneling With 12Mm Thick Nosva Pan Or Ancholam Board Prelamimated Board Rated On Both Side As Required, Guiding Rail Section, Vertical Rails Section Includingproviding Pvc Guidrails Of Six 12Mmx75mmas Required At Size Concealed Type Locking Arrangement And Heavy Duty Handle Set As Per Requirement Including Providing & Fixing Of18mm Thick Commercial Ply With Approved Laminate Of 1.5Mm Thick And Teak Wood Lipping Patti And Non-Laminated Surfaces Should Be Polished With Approved French Polish At Requiredshade & Colour. , Excavation Mechanically ( Using Excavators Like Jcb / Poclain / With Bucket ) In All Types Of Soil, Including Murrum, Soft Rockfor Foundations, Wall, Columns, Plinth Beams, Basement, Raft, Ducts, Trenches, Underground Sumps, Septic Tanks, Soak Well Including Shoring And Strutting, Bailing Out Water / Pumping Off Water If Required, Removing And Stacking Or Disposing Simultaneously The Excavated Soilanywhere Within The Actrec Campus And / Or Spreading Soils In Layers For Site Development. All Complete As Per Specification And As Directed By The Engineer-Incharge. For Depth Upto 1.5M. , Removal And Stacking Of Paver Blocks Taking Out Existing Cc Interlocking Paver Blocks From Footpath / Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Dry Stone Rubble Soling / Pitching Of 230-250Mm Size Shall Be Approved Quality, Hard, Free From Cracks, Durable, Preferably Black Trap. Rubble Shall Be Laid On Leveled Base Close To Give Compact, Surface. If Base Is Not Properly Leveledsame Will Have To Be Done Without Any Extra Cost. Voids In The Joints Shall Be Filled With Selected Chips. A Sample Of Paving Shall Be Prepared And Got Approved Before Proceeding Ahead. After Stones Are Laid With Thickness Of 200Mm And Packed With Chips, Sandshall Be Spread And Watered To Fill Remaining Voids. Sandshall Be Allowed To Go Into Joints Till Final Packing Is Obtained. Rate Quoted Shall Be For Materials, Labour, Watering, Leveling Site, Before Paving, Consolidating Etc. Complete. , Providing & Fixing Soap Dispenser Metallic Bottle. , P&F Soap Dish Holder. , Providing & Fixing Toilet Paper Holder With Flap Recessed Type ( Stainless Steel ) . , P&F Stainless Steel Surface Mounted Sanitary Napkin Disposal ( With Flap ) Of Approved Quality / Make. Cabinet - 18-8, Type-304, Stainless Steel Size 270Mm ( L ) X 105Mm ( W ) X 385Mm ( D ) Capacity:- 4.6 Litres Equipped With Full-Length Stainless Steel Piano Flap , Paper Towel Dispenser. Cabinet - 18-8, Type-304, Size 265X90x365 Stainless Steel Finish: Stainless Steel Satin Capacity: 450 C-Fold, 600 Multifold , P & F Stainless Steel Hand Dryer Of Approved Quality / Make. Casing:Stainless Steel # 304 Non Magnetic, Matt Finish Mounting :Wall Mounted Operation :Touch-Free Infra-Red Activation Sensor Range : 12 Cm - 15 Cm Hand Dry Time :Less Than 20 Secs Auto Cutoff: 30 Seconds Motor:Brush Type, Dual Ball Bearings Speed:25, 000 Rpm Rated Power :550 W ( No Heating Element ) Current:2.5 A Protection Class :Ip X 1 Blowing Volume : > 270 M3 / H Air Speed:95 M / S ( With Speed Controller ) , Modular Cubicle Based Restrooms Of Stainless Steel Make With Stainless Steel Hardware With Locking Arrangement And 1 Spare Lock Each.Handles And Hinges To Be Included In The Rate. Measurement Per Cubicle. , P & F 1St Quality Wvc Urinal ( Is:2556 Mark ) With 25Mm Dia G.I. Waste Pipe, Dome Waste Couplings, Concealed Iron Brackets Or Screws Etc. Complete. Cera Cat No: S4010101 Efs Or Equivalent , P & F 12Mm Thick Toughened Glass Urinal Partition With All Type Fitting. ( Partition Size 300Mm X 1050 ) , Providing & Laying Cast-In-Situ Rcc M25 Grade Of Concrete. Reinforced Cement Concrete: ( Rcc ) Reinforced Cement Concrete Of M25 Grade Using Graded Stone Aggregate Of 20Mm Max. Size Including Consolidation With Vibrator & Needle Of Required Capacity Finishing Curing Including Form Work, Shuttering And Steel Reinforcement Etc. Complete All As Directed By The Engineer-In Charge. , A ) . Columns ( Rmc ) , A ) . Lintel & Tie Beams ( Rmc ) , B ) . Sunshades ( Rmc ) , Reinforcement: Reinforcement For Reinforced Cement Concrete At All Floors And Levels Including Supplying Cutting Bending Fixing And Binding In Position With 1.6Mm Dia Soft Drawn Annealed Binding Wire Including Cost Of Binding Wire Labour Etc. Complete All As Per Specifications And As Directed By The Engineer-In-Charge. ( Laps Will Not Be Measured ) . With High Yield Strength Deformed Bars ( Tmt Bars ) & Ms Round Bars , Providing And Fixing Of Steel Shuttering Wherever Required As Per The Instruction Of Engineer Incharge , Brick Work: Brick Work At All Floor Level With Cement Mortar 1:4 Using Well Burnt Locally Available Bricks Of Approved Quality Including Scaffolding, Raking Out Joints Above Ground Level Simultaneous And As Directed By Engineer In Charge. In Foundation & Plinth Drain Walls Chambers & Superstructure Of All Floor Levels , Providing & Laying Of 20Mm Thk. External Wall Plastering With Ready Made Plaster Of Approved Make. Cement Plastering: Cement Plastering For Internal Wall And Ceiling With Cement Mortar 1:4 Finished Smooth With Neeru Over Brick Walls Of Concrete Surfaces Including Hacking The Concrete Surfaces At All Floors And Levels In Quantities As Required At Site Including Scaffolding Curing, Etc. Complete All As Directed By Engineer-In-Charge. , Providing & Laying Of 20Mm Thk. Internal Wall Plastering With Ready Made Plaster Of Approved Make. Cement Plastering: Cement Plastering For Internal Wall And Ceiling With Cement Mortar 1:4 Finished Smooth With Neeru Over Brick Walls Of Concrete Surfaces Including Hacking The Concrete Surfaces At All Floors And Levels In Quantities As Required At Site Including Scaffolding Curing, Etc. Complete All As Directed By Engineer-In-Charge. , Providing & Applying Of 2 Coats Of Apex Weatherproof Paint Alongwith One Coat Of Primer To The Out Side Plastered Surfaces. , Providing & Applying Of Oil Bound Distemper To Theinside Plastered Surfaces , Providing & Laying Of Cc Flooring ( 50Mm Thk ) As Per The Instruction Of Engineer Incharge. , Aluminum Openable Windows Providing & Fixing In Position Aluminium Openable Window Shutter With Frame Fully Glazed / Aluminium Grills Withusing 5.5Mm Thick Glass Sheet Of Approved Make And Qualityplain / Frusted / Bajari Glass Of Approved Make Fixed With Aluminium Beedingchannels With Two Way Rubber Gasket / Pvc Lining To Ensurewater Tightness And Nos Rattling For Aluminium Grill Fixing With Fchannel Beeding Using Satin Finish Anosdized 15 Micron Jindalsectionsfor Shutters And Frameof Required Size And Sectionincluding Using Aluminium / S.S. Hinges Of Required Size, Tower Bolt Of Required Size, C Type Alum Handle For Shutterand Othernecessary Hardware As Per Requirement Etc. Complete All Asper Specified And Directed By Engineer In Charge. The Sections Should Be Anodised. , Labour Charges For Alum Works : Removing The Existing Partitions / Doors And Handing Over The Same At Required Place Anywhere Inside The Actrec Campus As Indicated By The Engineer In Charge. Etc. Complete. , C.P.V.C. Pipes:Providing, Laying, Jointing, Fitting, Testing Heavy Quality C.P.V.C. Pipes Of Required Dia Including All Fittings Including All Brass Fixtures Such Mt And Ft Required As Per Site Requirement & Laying The Same At Any Floor Levels Including Scaffolding All Jointing Materials & Clamping In Wooden Blocks If Required Etc. Complete As Directed & Specified By Engineer-In-Charge. , 15Mm , 20Mm , 25Mm , 50Mm , Vetrified Dado Tiles Providing & Laying Polished Vitrified Floor Tiles In Different ( From 500Mm To 800Mm ) Sizes ( Thickness To Be Specified By Manufacturer ) With Water Resistant Less Than 0.08% And Confirming To Is 15622 Of Approved Make In All Colours & Shades, Laid On 20Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete As Per The Instruction Of Engineer Incharge. , Vetrified Floor Tiles: Providing & Laying Polished Vitrified Floor Tiles In Different ( From 500Mm To 800Mm ) Sizes ( Thickness To Be Specified By Manufacturer ) With Water Resistant Less Than 0.08% And Confirming To Is 15622 Of Approved Make In All Colours & Shades, Laid On 20Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete. , E.W.C.:Providing And Fixing White Vitreous China Pedestaltype Water Closet ( European Type W.C. Pan ) With Seatand Lid, Level White P.V.C. Flushing Cistern With Capacity As Mentioned Below, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittingsand Fixtures Complete Including Cutting And Makinggood The Walls And Floors Wherever Required. It Should Include P Or S Trap As Per Approved Make With Left Or Right Vent In Position Including Fixing It On Chair Brakcet Or Wall Bracket. With Necessary C.P. Brass Screws & Plugs Etc.Floor Mounted Ewc Universal With 5 To 7 Ltrs Cistern:Special Colour As Per Instruction , Pressmatic Taps :Urinal Valve Auto Closing System With Built-In Control Cock With Wall Flange . Providing And Fixing Including Removal Of Existing If Any As Per The Instruction Of Eic , Granite: Providing And Fixing 18Mm Thick Gang Saw Cut Mirror Polished Premoulded And Prepolished ) Machine Cut For Kitchen / Toiletplatforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size Of Approved Shade, Colour And Texture Laid Over 20Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With Joints Treated With Whitecement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc Complete At All Levels Of Colour Black / Red / Grey Etc. , Providing And Laying Water-Proofing Treatment Of Average 100 Mm Thick For Sunk Slabs Of Toilets And Wherever Necessary At All The Levels With Brick / Stone Aggregates, With Layer Of 20 Mm Thickcement Mortar 1:3 ( 1 Part Cement : 3 Part Coarse Sand ) Mixed With Water Proofing Compound As Specified By The Manufacturer, Layingbrick Bats Of Required Size Impregnating In To The Base Mortar Bed With Gap Of 12 Mm All Aroundaccording To Slope, Level And Curing The Same, The Gaps Around Brick Bats Filled With Cement Mortar 1:3 ( 1 Part Cement : 3 Part Coarse Sand ) Mixed With Waterproofing Compound, 20-30 Mm Layer Above Brick Bats And Finishing Top With Neat Cement @ 2.75 Kg / Sq.M. Screeding And Curing Etc. In Line, Level And Plumb / Slope, Complete Including Furnishing Of Guarantee For 10 Years. ( Note : The Above Rates Shall Be Inclusive Of Providing And Mixing Of Waterproofing Compound As Per Manufacturers Specifications ) , Fancy Pillar Tap: Providing & Fixing Approved Make Heavy Quality C.P.Brass Screw Down Pillar Tap Long Nose Not Less Than 810Gm. With Jam Nut Easy Clean Variety Of 15 Mm N.B. Etc. Complete All As Directed By The Engineer-In-Charge , Nahani Trap: Providing & Fixing 100Mm Dia C.I Heavy Duty Nahani Trapwith Bras C.P. Dome Type Heavy Duty S.S. Jali All As Approved Make Quality As Specified And Directed By Engineer In Charge One Way / Two Way Need Concrete Joints.Extra If Required , Water Shower Moc Ss 304 With All Necessary Arrangements . , Overall Size - ( 2450 X 2000 X 2000 ) Mm. , Pass Box Dynamic -Dynamic Pass Box , Made Out Of Ss 304 With No 4 Finish. Should Have 600 Mm ( H ) , 600Mm ( W ) And 600 Mm ( L ) Internal Sizes , Supply Of Ss Wall Bench Bench With Ss Sink And Sensor Tap Of Size 750L X750w X900mmh As Per The Layout Drawing Consists Of Moc: Ss 304Sheet Finish: No4 Mat Under Bench Storage Module Having450x450x180 Ss Sink Sensor One Way Tap Shutters And Accessories Likesshinges, , Ss D-Handlesetc., Pedestal With Adjustment Set And 25 Mm Double Skin Puf Infilled Top , Drain Collection Tank With Weighing Scale: , Supply Of Emergency Eye Wash Shower Moc Ss-304 , Electrical Work , Dg Set -Supply , Installation, Testing & Commisioning Of Diesel Generating ( D.G. ) Set With Class G3 Governing ( 40% Step Load ) , Alternator Of 625 Kva Output At 0.8 Pf Continuous Rating With 10% Overload Capacity For 1 Hour In 12 Hours, 3 Phase, 415 V, 50C / S, Radiator Cooled, Multi-Cylinder Diesel Engine At 1500 Rpm , Seperately Excited Amg Having Class H, Spdp Alternator ( With Battery Charging Generator ) , With Static Avr + / - 1% & Thd<3%, Running At 1500 Rpm. Both The Engine And Alternator Shall Be Direct Coupled On A Common Fabricated Steel Base Frame Anti Vibrating Pad Mounted With Controller Suitable For Full Parallel Operation Of Multiple Generators Having Engine & Generator Protection ( Including Ref & Rpr ) / Parameter Display / Operator Interface / Power Command 3.3 Control System / Amf Panel / Synchronization / Dedicated Earthing System / Rs 485 Modbus Connectivity, Etc. The Complete Set Shall Be Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit In Silenced Accoustic Canopy, Giving 75 Db At 1 Meter, Made Of 16 / 14 Swg Crca Sheet, Complete With First Filling Of Lube Oil / Diesel / Coolant & Fuel Hoses, Battery, 990 Liter External Fuel Tank, Residential Silencers, Mounted On Plinth & Obtaining Necessary Approval From Electrical Inspector. A ) Exhaust Piping To Be Raised Upto Terace Level Of Nearest Building. B ) Power / Control Cabling, Terminations, Etc. C ) 990 Ltr. Capacity External Deisel Tank.D ) . Height Of Stack To Be Maintained As= Height Of Building + 0.2 * Vkva . E ) Factory Testing To Be Carried Out In Present Of Actrec Engineering Before Despatch Of Equipments. , 625 Kva Dg Set , Amf Panelsuitable For 625 Kva Diesel Generating Set With Battery Charger And Standard Accessories. , Ms Class ‘B’ Diesel Engine Exhaust Pipe Of Suitable Size ( Including All Fittings, Clamps, Steel Support ) Of Suitable Dia For The Engine. The Pipe Shall Be Provided With 12 Mm Thick Ceramicfibre Rope And Below To Be Insulated With Cloth And Glass Wool. , Supply & Installation Of Exhaust Pipe Thermal Insulation And Cladding. , Installation Of Silencer , Supply & Installation Of Silencer Thermal Insulation And Cladding , Supply & Installation Of M.S. Supports For Exhaust Pipe & Exhaust Structure Suitable For 1 X 200 Mm Exhaust Pipe ( Structure Height -25 Mtrs ) Including Standar Panel & Tray , Supply & Installation Of S.S. Bellows 200 Mm With Matching Flanges, Gaskets And Fasteners , Ups - 3 Phase In 3 Phase Out With Igbt-Pwm Based Rectifier Technology With Isolation Transformer Ac Input Voltage:415 V + / - 10% , Frequency:50 Hz + / - 5%, Output Voltage:415V + / - 2% , Output Frequency:50Hz + / - 0.5%, Efficiency: 0.9. Type Of Battery:Smf, Battery Capacity: For A Backup Time Of As Specified, Battery Charging Current:Shall Be Calculate For Unity Power Factor. Protection: Electronic Over Voltage Trip, Electronic Under Voltage Trip, Single Phase Prevention, Overload, Short Circuit And Battery Overcharge, Indications: Ac On, Inverter On Charger Fuse, Inverter Trip. One Number Rs232 Ports To Steady The Data With All Accessories Complete Etc., , 160Kva Online Ups With Isolation Transformer 3-Phase I / P And 3-Phase O / P With 30Minutes Backup. , Sealed Maintenance Free Batteryof 34Nos, 12V / 130Ah, 30Minutes Backup. , Battery Rack With Accessories For 160Kva Ups. , Lv Panels - Free Standing, Floor Mounted Mcc Panel Made Out Of 2Mm Thick Crca Sheet Duly Powder Coated After Seven Tank Process Consisting Of Suitable Rating Incomer, Aluminum Bus Bar Supported With Dmc / Smc Barriers & Color Coded With Heat Shrinkable Sleeves, Metering And Outgoing Feeders ( As Mentioned Against Each Panel ) : , Mcc Panel-1 For Ahu 1, 2, 3, 4, 5, 6, 7, 8 Ahu For Exhaust-2 Nos, Mcc 2, Ups, Ldb - 1, Pdb-1&2 ( As Per Enclosed Sld ) . , Mcc Panel-02 For Air Cooled Chiller-1, 2 &3 Chilled Water Pump-1, 2, 3, 4, 5, Hot Water Generator-1, Hot Water Generator-2, Hot Water Pump-1, Hot Water Pump-2. ( As Per Enclosed Sld ) , Ups Panel For Eldb-1 , Epdb-1 , Epdb-2 & Epdb-3. ( As Per Enclosed Sld ) , Lv ( Power & Control ) Cables - 1.1Kv Grade Xlpe / Pvc Insulated Aluminum / Copper Multi-Strand Conductor Steel Armoured Cables. , 3.5C X300mm² Al. Armd. Xlpe Insulated Cable. , Excavation And Cable Layoing And Backfilling As Per The Iso Norms , 3.5C X240mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X185mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X150mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X 50Mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X 25Mm² Al. Armd. Xlpe Insulated Cable. , 4 C X 4Mm² Cu. Armd. Xlpe Insulated Cable. , 4 C X 2.5Mm² Cu. Armd. Xlpe Insulated Cable. , 3 C X 6Mm² Cu. Armd. Xlpe Insulated Cable. , 3 C X 4Mm² Cu. Armd. Xlpe Insulated Cable. , 3 C X 2.5Mm² Cu. Armd. Xlpe Insulated Cable. , 1C X35mm² Cu. Unarmd. Xlpe Insulated Cable. , 1C X70mm² Cu. Unarmd. Xlpe Insulated Cable. , Lv Cable End Terminations - Termination Of Cables With Brass Double Compression Glands Including Cost Of Crimping Lugs / Ferrules, Solder, Cable Sockets, Insulation Tapes Etc. , 3.5C X300mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X240mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X150mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X185mm² Al. Armd. Xlpe Insulated Cable. , 3.5C X 50Mm² Al. Armd. Xlpe Insulated Cable Terminations. , 3.5C X 25Mm² Al. Armd. Xlpe Insulated Cable Terminations. , 4 C X 4Mm² Cu. Armd. Xlpe Insulated Cable Terminations. , 4 C X 2.5Mm² Cu. Armd. Xlpe Insulated Cable Terminations. , 3 C X 6Mm² Cu. Armd. Xlpe Insulated Cable Terminations. , 3 C X 4Mm² Cu. Armd. Xlpe Insulated Cable Terminations. , 3 C X 2.5Mm² Cu. Armd. Xlpe Insulated Cable Terminations. , 1C X35mm² Cu. Unarmd. Xlpe Insulated Cable Terminations. , 1C X70mm² Cu. Unarmd. Xlpe Insulated Cable Terminations. , Earthing - Supply, Installation Testing Of Earthing Station As Per Is Standard Complete With 600X600x6mm Gi Plate Electrode, Salt, Charcoal, 2 Nos. 50X6 Mm Aluminum Strip Upto Test Link, 40 Mm Dia G.I. Watering Pipe With Funnel, And Test Link. The Chamber Size Shall Be Fitted With450 X 450 Mm With Heavy Duty C.I. Chamber Cover Duly Painted And Marked With Pit Identification Number Both Inside And Outside As Per Earthing Layout Drawing. , 50X6mm Gi Strip. , 25X3mm Gi Strip. , 6Mm² Single Core Multi Strand Wire ( Green Color ) . , 10Mm² Single Core Multi Strand Wire ( Green Color ) . , Supply, Installation Testing Of Earthing Station As Per Is Standard Complete With 600X600x3mm Copper Plate Electrode, Salt, Charcoal, 2 Nos. 50X6 Mm Copper Strip Upto Test Link, 40 Mm Dia G.I. Watering Pipe With Funnel, And Test Link. The Chamber Size Shall Be Fitted With450 X 450 Mm With Heavy Duty C.I. Chamber Cover Duly Painted And Marked With Pit Identification Number Both Inside And Outside As Per Earthing Layout Drawing. , 50X6mm Copper Strip. , 25X3mm Copper Strip. , 2000Mmx1000mmx12mm Corriguated Rubber Mats, As Per Standards. , D.C.P. Type Fire Extinguisher For Following Capacity Cartridge Type With Gun Metal Cap 150Gram Co2 Gas Cartridge, Powder And Brackets Confirming To Is 2171-19885 Andcompleted Erected With Necessary Clamps Made From 50 X 6Mm. Ms Flat With Nut & Bolts Grouted In Wallcomplete. 6Kg Capacity. , Carbon Dioxide ( Co2 ) Fire Extinguisher User Of Following Capacity With Necessary Clamps Made From 50 X 6Mmm.S. Flat With Nut & Bolts Grouted In Wall Complete. 4.5 Kg Capacity. , Mcb Distribution Boards :- , 12Way Three Phase Power Distribution Board With Vertical Double Door Type ( Vtpn Db ) With 125A Tpn Mccb As A Incomer & 12 Nos. 32A Tpmcb As Outgoing Circuit. Mcb Shall Be Provided With “C” Curve. , 8Way Three Phase Power Distribution Board With Vertical Double Door Type ( Vtpn Db ) With 125A Tpn Mccb As A Incomer & 8 Nos. 32A Tpmcb As Outgoing Circuit. Mcb Shall Be Provided With “C” Curve. , 1 Phase, 8 Way Lighting Distribution Board With Horizontal Double Door Type40a Dp El Mcbas A Incomer, 6Nos. 6-10A Sp Mcb As A Outgoing Circuit. Mcb Shall Be Provided With “C” Curve , 3 Phase , 12 Way Distribution Boards With Horizontal Double Door Type ( Etpn Db ) With Per Phase Isolation Kit , 63A Tpn Mcb As A Incomer, 40 A Dp Mcb Per Phase& 30 Nos. 16A / 20A Sp Mcbin Outgoing Circuit . ( 10 Nos, Mcb Per Phase ) ( Pdb ) . Mcb Shall Be Provided With “C” Curve , 3 Phase , 8 Way Distribution Boards With Horizontal Double Door Type ( Etpn Db ) With Per Phase Isolation Kit , 63A Tpn Mcb As A Incomer, 40 A, 300Ma, Dp Elcb Per Phase& 18 Nos. 16A / 20A Sp Mcbin Outgoing Circuit . ( 8 Nos, Mcb Per Phase ) ( Pdb ) .Mcb Shall Be Provided With “C” Curve , Modular & Industrial Type Switch Sockets - Switch Socket Industrial Type -Industrial Pentra Type Socket & Plug With Mcb Enclosed In Enclosure. The Scope Includes Fixing Of Enclosures , Supply Of All Fixing Accessories / Hardware. Mcb And Socket Shall Be Wired Up Upto Outgoing Terminals Etc, Complete As Required. , Single Phase 25 Amp 3 Pin Socket With Straight Connected Plugwith 25 Amp Dp Mcb. , Single Phase 32 Amp 3 Pin Socket With Straight Connected Plugwith 32 Amp Dp Mcb. , Three Phase 32 Amp 5 Pin Socket With Straight Connected Plugwith 32 Amp Fp Mcb. , Modular Type Switch / Sockets / Lan / Telephone System- The Crca Modular Box Shall Be Concealed In Such Way That Front Plate Flush Withmodular Partition Wall And& Brick Wall Front Plate Shall Be Ss 304 Matt Finish. , 16 Amp Switch 1 Nos. With Modular Box, Front & Rear Plate. , 16 Amp Switch 2 Nos. With Modular Box Front & Rear Plate. , 16 Amp Switch 3 Nos. With Modular Box Front& Rear Plate. , 6 / 16 Amp Switch Socket 1 No. With Modular Box Front & Rear Plate. , 6 / 16 Amp Switch Socket 2 No. With Modular Box Front & Rear Plate. , Rj45 Lan Socket 1 Nos. With Modular Box Front & Rear Plate. , Rj11 Lan Socket 1 Nos. With Modular Box Front & Rear Plate. , Rj45 Socketeach 1 Nos. With Modular Box Front & Rear Plate. , Cat - 6 Flexible Cable. , 50 Pair Telephone Junction Box , 12U Rack With 4 Nos. 24 Port Patch Panel With All Accessaries. , Wi-Fi Network Point With All Accessaries. , 50 Pair Telephone Cable , Ip Telephone Instrument , Analogue Telephone Instrument , Supplying And Fixing 1 Meter Length, Utp Patch Cord Of Cat 6 Type In Position As Per Requirement. , Supplying And Fixing 7 Ft Length, Utp Patch Cord Of Cat 6 Type In Position As Per Requirement For End Point Device ( Pc / Laptop Etc ) , Sitc Of Lazr Speed 300 Fiber, 6 Core- Indoor Application, Multimode, To Be Laid Through Conduit And Flexible With All The Connectors, Couplers, Pigtels, Lius At Both Endcrca Module Box , The Crca Module Box Shall Be Concealed / Surface Mounted On Brick Wall / Modular Partion. , Light Fixtures , 42W Led Bottom Openable Type Cleanroom Light Fixtutre. , 20W Led Bottom Openable Type Cleanroom Light Fixtutre. , 39 / 40W Led Batten Type Light Fixtures. , 1.1 Kv, Grade Frls, Pvc Insulated Multi-Strand Copper Flexible Cables , 3C X 1.5Mm² Cu. Flexible Cable. , 3C X 2.5Mm² Cu. Flexible Cable. , 3C X 4Mm² Cu. Flexible Cable. , 3C X 6Mm² Cu. Flexible Cable. , 5C X 6Mm² Cu. Flexible Cable. , 3C X 10Mm² Cu. Flexible Cable. , Flexible Cable Terminations Including Crimping Lugs / Ferrules Etc. Complete As Required , 3C X 1.5Mm² Cu. Flexible Cable Terminations. , 3C X 2.5Mm² Cu. Flexible Cable Terminations. , 3C X 4Mm² Cu. Flexible Cable Terminations. , 5C X 6Mm² Cu. Flexible Cable Terminations. , 3C X 10Mm² Cu. Flexible Cable Terminations. , Supply And Installation Of Gi Perforated & Ladder Cable Trays :- - Hot Dipped Galvanized And Minimum Thickness Of Hot Dip Coating Is 70 To 100 Microns. Thickness Of Cable Tray Sheet Steel For 50 Mm To 300 Mm Cable Tray 2.0Mm Thickminimum Height Of The Perforated Cable Tray Is 30Mm Or 50Mm. Cable Tray Shall Be In Different Widths And Shall Be In Standard Length 2500Mm Long And Suitable To Couple Two Cable Trays With Coupler. Support Required For Fixing The Cable Trays Considered In The Structural Steel , 50Mm ( W ) X 50 Mm ( H ) X 2Mm Thinkness Perforated Cable Tray. , 100Mm ( W ) X 50 Mm ( H ) X 2Mm Thinkness Perforated Cable Tray. , 150Mm ( W ) X 50 Mm ( H ) X 2Mm Thinkness Perforated Cable Tray. , 300Mm ( W ) X 50 Mm ( H X 2Mm Thinkness Perforated Cable Tray. , 450Mm ( W ) X 50 Mm ( H ) X 2Mm Thinkness Perforated Cable Tray. , 600Mm ( W ) X 50 Mm ( H ) X 2Mm Thinkness Perforated Cable Tray. , Structural Steel For Supports. , Pvc Conduit With Bends, Junction Boxes, And All Necessary Accessories And Hard Ware As Following. , 25 Mm Pvc Conduit. , Pvc Flexible Conduit With Clamps And All Necessary Accessories And Hard Ware As Following. , 25 Mm Flexible Conduit. , Ceiling Fan , 1200Mm Sweep Ceiling Fan , Bms System Software , Bms Software: Graphical User Interface Software Based On Ms Windows With1000 Points & 1 Client License .The System Should Be Accessible From Anywhere On Lanor Ethernet . The Communication Protocol Shall Be Bacnet Protocols . System Should Be Scalable In All Levels , Eggineer And User Level Passwords. , Bms Client Station:Intel I7 3Rd Generation Processor 3Ghz, With 1Tb X 2Nos Hard Disk, 16 Gb Ram / Dvd-Rw / Keyboard / Optical Mouse / Lan Card / 32” Led Monitor. Minimum 4 Usb Ports. With Pre-Loaded Licensed Windows 10 Professional Software ( Latest Version ) , Ms Office And Anti Virus, Dual 2Gb Graphic Cards As Per Tender Specification. , Server Pc:- The Main Servers Will Be Intel Xeon Processor E5-2600, Minimum Speed Of 2.3 Ghz With 6 Core, Dual Gigabit Ethernet Port, Usb Port, Video Port. The Server Memory Will Be 16 Gb Ddr4 Ram With 21 Inch Monitor , Laser Printer For Alarms And Reports - A4 Size ( Black & White ) , Ddc Panels - Ip Based Ddc Controllers With In-Built Real Time Clock, 32 Bit Micro-Processor Cpu, Memory, Enclosed In Ms Powder Coated Enclosureas Per Io Summary , Ddc-1&2 ( Ahu-1, Aeu-1 & Ahu-6, Aeu-6 ) With Io Points Ofai - 26, Di - 24, Ao - 10 & Do - 08 , Ddc-3&4 ( Ahu-2, 3 & Ahu-4, 5 ) With Io Points Of Ai - 22, Di - 14, Ao - 08 & Do - 04 , Ddc-5 For Emswith Io Points Of Ai -62 , Di - 0, Ao - 18 & Do - 0 , Gatewaymodule For Integrating The Third Party Systems Communicating On One Of The Standard Open Protocols Such As Bacnetand Modbus, Etc With Bms , Chiller Intigration, Energy Meters, Hot Water Generator , Field Instruments - Testing And Commissioning Of Following Instruments With Required Accessories , Dp Switch Across Fan To Monitor Filter Clog Status Monitoring ( Fine Filter ) Range: Max 1000 Pa , Differential Pressure Switch For Ahu Run Status Range: Max 500 Pa , Duct Dp Transmitter Across Fan , Room Temp, Rh & Dp Display Unit With Inbuilt Dp And External Temp & Rh Transmitter , Static Pressure Senosr For Vfd Speed , Duct Mount Temperature & Rh Sensor With Temp Accuracy: ±2% & Rh Accuracy: ±3% , Damper Actuators , Room Temperature & Rh , Control Cables, Cable Trays And Conduits With Accessories. , 6C X 1 Sq Mm Armoured Copper Shielded Cable , 4C X 1 Sq Mm Armoured Copper Shielded Cable , 2C X 1 Sq Mm Armoured Copper Shielded Cable , Shielded Cat 6 Cable, 4 Pair, Utp, 24 Awg Cable , Gi Perforated Cable Tray 50 X 50 X 2 Mm With Required Ms Supports , Gi Perforated Cable Tray 100 X 50 X 2 Mm With Required Ms Supports , Gi Perforated Cable Tray 300 X 50 X 2 Mm With Required Ms Supports , 25 Mm Pvc Conduit With Its Mounting Accessories , 8 Port Network Switch With Rack , Validation & Documentation : Thevalidation To Be Done After The Validation & Commisisoning Of The Facility , Validation And Commissioning Of Entire Facility Including The Qualification And Operational Approach ( Protocols For Sat And Iq And Oq, Or Ioq ) .Validation Of The Bms System With Related Qualification Documents Dq / Iq / Oq / Pq As Per International Norms And Client Standards. , Fire Alarm System , Addressable2 Loop Fire Alarm Control Panel ( Facp ) With Battery Charger And With The Battery Back Up For 8 Hours Normal Operation And One Hour Alarm Operation.The Facp Shall Be Expandable Upto 10 Loop. The Facp Shall Include A Full Featured Operator Interface Control And Annunciation Panel That Shall Include A Backlit 640-Character Liquid Crystal Display, And A Qwerty Style Alphanumeric Keypad For The Field Programming And Control Of The Fire Alarm System.System Should Support Upto 159 Detectors And 159 Modules In One Loop. The Panel Shall Be Ul Listedand Fm Approved And Comply Ul 864, 9Th Edition Requirement. The Enclosure Shall Also Be Ul Listed. The Quoted Rate Shall Include Supply Of Necessary Software And Harware For Progamming The Panel With All Necessary Licence. ( With Fiber Support ) , Intelligent Analog Addressable Photothermal Detector Complete With Mounting Base Complete As Required. , Intelligent Analog Addressable Hest Detector Complete With Mounting Base Complete As Required. , Manualcall Point With Address Switch To Programme The Modules Which Monitors And Reports Contact Status..Complete As Required As Per Technical Specification. , Addressable Horn Cum Strobe Complete As Required. , Analogue Addressable Control Relay Module For Ahu Tripping And Shall Bewith The Facility Of Hard Addressing, Capable Of Providing Dpdtcontact Rated At 24V Dc, 2A.Complete As Required As Per Technical Specification. , Should Be Capable Of Monitoring Shorted Loop Circuit And Automatically Restore Communications When Shorted Condi , Analogue Addressable Control Module Shall Be With The Facility Of Hard Addressing, Capable Of Providing Dpdtcontact Rated At 24V Dc, 2A.Complete As Required As Per Technical Specification. , Active Repeater Panel With Minimum 640 Character Backlight Lcd Display With Qwerty Keypad And Fixed Function Keys And Soft Keys. It Should Have Control And Display Capabilities For All Nodes Of The Network. Should Have The Facility To Store 1000 Alarm Event & 4000 System Events. The Panel Shall Be Ul Listed And Fm Approved.Complete As Required As Per Technical Specification. ( With Fiber Support ) , Response Indicator , 2C X1.5 Mm², Pvc Insulated Frls Armoured Copper Cable For Slc Loop & Power Supply, Confirming To Is Standards And Specifications..Complete As Required As Per Technical Specification. , 25Mmsizeofmediumclasspvcconduitalongwith Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Exit Signages , 10A Power Supply Unit , Access Control System , Door Access Control System - Access Control Desktop Pc With Thefollowingminimumspecifications:Intelcorei5, 3Ghz, 4Gbram, 500Gb Hdd, 32Lcdmonitor, Usbmouse, Usbkeyboard, Dvd / Cdwriter, Modem / Ip Connectivity, Hdmi Output, Configurationwithwindows10 Pro, Office 12 And Antivirus , Access Control System Software , Time Attendance Software System As Per Clients Requirement. , Access Control System Will Be Magnetic Door Type Controlled Through Card Readers And Biometrically Inncluding All Accessories And With Necessary Cables And Terminations. The System Will Be Capable To Record The Biometric Attendance Of The Authorized Personnel And The Records Will Be Stored In Server. Magnetic Lock And Door Sensor , Emergency Release Switch In Green Polycabonate Housing / Push To Break Glass Type , Proximity Cards Complete As Required , Cat 6 Cable , Ethernet Switch 16 Channel , 25Mmsizeofmediumclasspvcconduitalongwith Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Arrangement Of Interconnection Between Fire Alarm System And Access Control System To Automatically Open The Door In Case Fire Emergency. , Door Interlock System , 2 Door Interlocking System With Controller Unit, In / Out Ss Pb , Electromagnetic Lock With Contact, Door Position Sensor, Emergency Release Switch, Control And Signal Cables, Conduits, Cables, Cable End Terminations Etc As Per The Attached Technical Specification. The Controller Shall Be Provided With Ethernet Communication Port. , 3 Door Interlocking System With Controller Unit, In / Out Ss Pb , Electromagnetic Lock With Contact, Door Position Sensor, Emergency Release Switch, Control And Signal Cables, Conduits, Cables, Cable Endterminations Etc As Per The Attached Technical Specification. The Controller Shall Be Provided With Ethernet Communication Port. , Cctv System , Professional Grade Network Video Management Recorder, Comprising 32Ch. Nvr To Record Output Of All Cameras Mentioned Above With 1920X1080p Resolution @30Fps, Third-Party Ip Camera Supported, H.264 Compression - Up To5megapixelsresolutionrecording, Multipleharddisksloteachhavingmaximumstoragecapacityof24tb, Minimum Of 30 Days Recording Motion / Continuous, 720P @ 25 Fps Recorded View, And 1920X1080p @30Fps Live View, 2 Usb 2.0 Or 3.0, Httpnetworkable, Backupbyusb / Dvdwr, Redundant Backup Of Nvr Scheme, Included Software, Client Licenses And Required Camera Licenses Complete As Per Technical Specifications And As Required. All The Components To Be Of Same Make As Camera. Nvr Shall Be Bis Certified. , Ip65dome Network Camera Full Hd 2 Mega Pixel Low Illumination Lux 0.5 High Sensitivity With 1 / 2 Inch Progressive Image Sensor, H.265+ Video Compression, 1920X1080 @ 20 Fps With Poe Powersupported, Onvif S Profile, Face Detection Etc, Operating Temp -10 To +40 Degree C, Certification Bis Approved. ( Indoor Application ) , Networktdnirindooroutdoorbulletcamera1by3cmos1, 3Mp3point6mmfixed24irledspoe H264, Excellent Low-Light Performance With 3D Noise Reduction, Saving Storage And Bandwidth Together With H.264 High Profile Codec , 24Portmanagedswitchwith Poe / Poe+, As Required, I / C Connections Ofl3 Switchwith 16Port Switchx 10 / 100 / 1000T Poe Ports And 4 X100 / 1000X Sfp Ports Complete Etc. As Required , Rj-45 Connectors , Closed Wall Mount Rack 12U , Led Display Monitor: - The Sufficient No. Of Full Hd Led Monitors With High Resolutions Screen Size Of 52” ( Diagonal ) Are To Be Provided For Viewing All Live / Recordedcameraproceedings.Theresolutionsof1920 ( H ) X1080 ( V ) Pixelswithcomfortableviewingangleis Proposedforallmonitorssuitableforoperationon220-240Vac50hzpowerforthedisplaypanelshouldbe Equipped With All Standard Features Such As Video In, Audio In, Hdmi / Dvi, Rj 45 Port Etc. , Cat-6 Utp Cable With Accessories. , Sitc Of 3 Core*1.5Sqmm Frls Unarmoured Power Cable With All Accessories Complete As Required. , 25Mmsizeofmediumclasspvcconduitalongwith Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , P.A. System , Six Zone Voice Controller With Necessary Interface To Fire Alarm System, And Zonal Configuration Facility Complete Along With Up To 255 Pre Recorded Message, Emg Evacuation Message , High Quality 6 Watt, 100Vspeakers With Box Ringin Ceilingmounted Type With Tansformer & Terminations. , 6W Volume Control Regulator , 250W Amplifier , Mixing Amplifier , Table Top Microphone. , Equipment Rack For Pasystem Unit With Secure Lock & Key. , Cd Player For Music Source , 0.75Sqmm Twin Twsted Wires For Speaker On Cable Tray Or Pre- Fixed Conduits Including Terminations. , 25Mmsizeofmediumclasspvcconduitalongwith Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , E.M.S. System , Standalone Controller - Operator Pc:- Pc With Thefollowingminimumspecifications:Intelcorei7, 3Ghz, 4Gbram, 500Gb Hdd, 32 Lcdmonitor, Usbmouse, Usbkeyboard, Dvd / Cdwriter, Modem / Ip Connectivity, Hdmioutput, Configurationwithwindows10 Pro, Office 12 And Antivirus ( Work Station , Operator Station , One Stand By As Per Spec ) , Ems Software , Converter For Intigration To Ems Systeam , 16 Port Ethernet Switch With Rack , 8 Port Ethernet Switch With Rack , Smps , Field Instruments , Room Dp Transmitter With Three Row Display Unit ( T&Rh And Dp ) , Room Temperature & Rh Transmitter , Control Cables, Cable Trays And Conduits With Accessories. , 6C X 1 Sq Mm Armoured Copper Shielded Cable , 3C X 1.5 Sq Mm Armoured Copper Cable , Shielded Cat 6 Cable, 4 Pair, Utp, 24 Awg Cable , Gi Perforated Cable Tray 50 X 50 X 2 Mm With Required Ms Supports , Gi Perforated Cable Tray 100 X 50 X 2 Mm With Required Ms Supports , Gi Perforated Cable Tray 300 X 50 X 2 Mm With Required Ms Supports , 25 Mm Pvc Conduit With Its Mounting Accessories , 1 Year Warranty Is Included In The Above Items. Cmc Including All Spare For The 6 Years After Warantee Period For Electrical Items , 2Nd Year Cmc After Handing Over The Project , 3Rd Year Cmc After Handing Over The Project , 4Th Year Cmc After Handing Over The Project , 5Th Year Cmc After Handing Over The Project , 6Th Year Cmc After Handing Over The Project , 7Th Year Cmc After Handing Over The Project , Hvac System , Air Cooled Chiller Units : - Supply , Installation Testing And Commissioning Of Air Cooled Screw Chillers Of Multiple Compressors, Machine Mounted Microprocessor Control Panel; Condenser Coils -As A Mandatory Requirement Shall Have A Factory Applied Anti-Corrosive Protective Coating Of Electro-Deposited And Baked Flexible Epoxy Coating, Insulated Cooler, Flow Switch At Cooler, Victaulic Coupling At Chilled Water Connection, Spring & Neoprene Pad Vibration Isolators, Integralrefrigerant Piping And Wiring, Accessories As Required And Called For, Automatic And Safetycontrolsmountedincentralconsolepanelandailmountedonasteelframe.Motorshallbesuitablefor 415±10% 50Cycles. 3 Phase Ac Supply. Refrigerant Used Must Be Ozone Friendly ( R134a Or Equivalent ) . The Noise Level For Each Chiller Should Not Exceed 80 Dba At 1 Meter, Measured At Any Point From The Chiller. Inlet Temp.Of Water - 12°C, Outlet Temp, Of Water - 7 °C . Rcc Foundation As Per Manufacturer Standard Has To Be Included Inthepriceas Permanufacturersdrawing.Allms Structurerequiredfortheinstallationofchillerisalsoincludedintheprice. Flexible Expansion Joint / Rubber Bellow And All The Accessories, Fitting Bolts, Nuts And Consumables Etc As Require Are Included In The Price.Microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, Tobehookeduptobmsfor Parameters Monitoring And Control. Ambient Temperature To Be Considered Asfor Navi Mumbai For Chiller Selection. Note:-Chiller Shall Be Factory Tested At Design Conditions At 100%, 75%, 50% And 25% Load. Factory Run Test: Chiller Shall Be Pressure-Tested, Evacuated And Fully Charged With Refrigerant And Oil, And Shall Be Factory Operational Run Tested. , Capacity - 60Tr ( 2W + 1S ) - Chiller Inlet @ 12.0 Deg C, Outlet @ 7.0 Deg C , Heat Pump - 150 Kw ( 1W+1S ) , Supply, Installtion, Testing And Commissioning Of Water Cooled Screw Chillers Of Multiple Compressors, Machine Mounted Microprocessor Control Panel; Water Cooled Condenser, Insulated Cooler, Flow Switch At Cooler, Victaulic Coupling At Chilled Water Connection, Spring & Neoprenepadvibrationisolators, Integral Refrigerantpipingandwiring, Accessoriesasrequiredandcalledfor, Automatic And Safety Controls Mounted In Central Console Panel And Ail Mounted On A Steel Frame. Motor Shall Be Suitable For 415±10% 50Cycles. 3 Phase Ac Supply. Refrigerant Used Must Be Ozone Friendly ( R134a / Equivalent ) . Thenoiselevelforeachchillershouldnot Exceed80 Dba, Measuredat Anypoint 1-Metersfrom The Chiller. Hot Waterinlettemperatureof450c, Outlettemperatureofwater500c.Chilledwaterinlettemp.Ofwater-12°C, Outlet Temp, Of Water - 7 °C . Rcc Foundation As Per Manufacturer Standard Has To Be Included Inthepriceasper Manufacturersdrawing.Allmsstructurerequiredfortheinstallationofchillerisalsoincludedintheprice. Flexible Expaansion Joint / Rubber Bellow And All The Accessories, Fitting Bolts, Nuts And Consumables Etc As Require Are Included In The Price. Microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, Tobehookeduptobmsfor Parameters Monitoring And Control. Ambient Temperature To Be Considered Asfor Navi Mumbai For Chiller Selection.Note:-Chiller Shall Be Factory Tested At Design Conditions At 100%, 75%, 50% And 25% Load. Factory Run Test: Chiller Shall Be Pressure-Tested, Evacuated And Fully Charged With Refrigerant And Oil, And Shall Be Factory Operational Run Tested. Hot Water Inlet @ 45 Deg C, Outlet @ 50.0 Deg C.Chiller Inlet @ 12.0 Deg C, Outlet @ 7.0 Deg C , Chilled / Hot Water Pumps- Supply, Installation, Testing & Commissioning Of Horizontal / Verticle Pumps. Pump Body : Cast Iron, Impeller : Stainless Steel / Aisi 316L. All Pumps Shall Be Aligned Properly As Required As Per Specifications.Minimum Efficiency Of The Pump Shall Be 75%. The Pump Motor Shall Be Suitable For 415 ± 10% Volts, 50 Cycles, 3 Phase Power Supply.The Motor Selected Shall Be Energy Efficient Having Efficiency ( Class I ) At Full Load Ranging Between 91.5% To 94% In Accordance With Motor Rating As Per Specification.Vendor To Check & Confirm The Motor Ratings As Specified For Outdoor Duty Application Consisting Of: A ) Pump And Motor ( Suitable For Outdoor And Continuous Operation ) , B ) Mounting Frame & Vibration Isolators, C ) Earthing Of Motor ( Ip-55 ) & Frame, D ) Lifting & Mounting Of The Pumps At Locations As Shown In Drgs. ( At Terrace Level ) , E ) All Accessories Require I.E. Flexibles, Eccentric Reducers And Expanders, Consumables Etc., F ) Insulation Of The Pumps And Accessories As Per The Given Specifications. , Chilled Water Pumps , Capacity:240Usgpmhead - 35M ( 1W +1S ) For Air Cooled Chiller , Capacity:106Usgpmhead - 35M ( 1W +1S ) For Heat Pump , Hotwater Pumps , Capacity:180Usgpmhead - 35M ( 1W +1S ) , Electrical Panel For Pumps For Chilled And Hot Water Supply Installation And Commissioning Of Electrical Panel For Pumps Including:A ) Logic Controller With Required Software, B ) All Mcbs, Mccbs, Vfds, Vfd By Pass Etc As Per Require, C ) Differential Pressure Sensors / Transmitters With Control Wiring, D ) Bms Compatibility , Electrical Panel For Pumps , Control Wiring Between Dpts And Main Controller / S , Air Separator Supply , Installation , Testing And Commissioning Of 125 Mm Dia. With 50 Mm Thick Polystyreneinsulation With 26 Gauge Aluminium Cladding For Chilled Water With All Assesories. , Supply , Installation , Testing And Commissioning Of 100Mm Dia. With 50 Mm Thick Polystyreneinsulation With 26 Gauge Aluminium Cladding For Hotwater With All Assesories. , Open Type Expansion Tank - Supply , Installation , Testing And Commissioning Of 1000L Ms Tank With 50 Mm Thick Polystyreneinsulation With 26 Gauge Aluminium Cladding With Make Up Water Connection, Over Flow And Drain Provisions For Chilled Water With All Necessary Foundation , Supply , Installation , Testing And Commissioning Of 1000L Pvc Tank With Make Up Water Connection, Over Flow And Drain Provisions For Hotwater With All Necessary Foundation. , Chilledwater Piping: - Supplying, Laying / Fixing, Testing And Commissioning Of Following Nominal Sizes Of Chilled Water Piping Plumbing Inside The Building ( With Necessary Clamps, Supports, Vibration Isolators And Fittings But Excluding Valves, Strainers, Gauges Etc. ) Duly Insulated With Fire Retardant Quality Expanded Polystrene Moulded Pipe Section Of Density 20 Kg / Cu.M After A Thick Coat Of Cold Setting Adhesive ( Cprx Compound ) Wrapping With 500G Polythene Faced Hessain And Finally Applying 0.63Mm Aluminium Sheet Cladding Complete With Type3 , Grade 1 Roofing Feltstrip ( As Per Is:1322 As Amended Up To Date ) At Joints Repairing Of Damage To Building Etc. As Per Specifications And As Required Complete In All Respect. Note:- The Pipes Of Sizes 150Mm & Below Shall Be M.S. C Class As Per Is : 1239 And Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is: 3589, From Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350 Mm Dia. , 150Mm Dia. ( 75 Mm Thick Insulation ) , 125Mm Dia. ( 50Mm Thick Insulation ) , 100Mm Dia. ( 50Mm Thick Insulation ) , 80Mm Dia. ( 50Mm Thick Insulation ) , 65Mm Dia. ( 50Mm Thick Insulation ) , 50Mm Dia. ( ( 50Mm Thick Insulation ) , 40Mm Dia. ( 50Mm Thick Insulation ) , 32 Mm Dia ( 50Mm Thick Insulation ) , 25 Mm Dia ( 50Mm Thick Insulation ) , Sitc Of Butterfly Valves, Required For Chilled Waterpiping Including Necessary Mating Flanges, Gaskets, Bolt & Nuts And Insulation As Mentioned Above. , 125 Mm Ø , 100 Mm Ø , 80 Mm Ø , Sitc Of Ball Valves Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 40 Mm Ø , 25 Mm Ø , Sitc Of Manual Balancing Valves Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 100 Mm Ø , 80 Mm Ø , Sitc Of Nrvs Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 100 Mm Ø , Sitc Of Y- Strainers Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 100 Mm Ø , Sitc Fabricatedchilledwater Manifoldfor Ahus As Below Having Chw Requirement For Chw Pipe Size As Below Comprising Of 1 ) 8 Rmt Of Ms Erw C Class Pipe As Per Is 1239 With All Necessary Fittings I.E. Bends, Reducers, Flanges Etc. 2 ) 5 Nos. Ball Valve / Butterfly Valve 3 ) 1 No. 2-Modulating Control Valve 3 ) 1 No. Balancing Valve 4 ) 1 No. Y Strainerscrewed / Flanged End. 5 ) 2 Nos. Pressure Gauges ( 1 In Supply Line & 1 In Return Line ) 6 ) 2 Nos. Temperature Gauges With Thermowell ( 1 In Supply Line & 1 In Return Line ) 7 ) 1 No. Auto Air Vent Valve Of Size 15Mm 8 ) 1 No. Drain Valve Of Size 25Mm 9 ) Insulation As Mentioned Above For The Manifold Pipe & Valve.Insulation To Be Provided Complete For Fittings ( Valves, Bends, Tees, Reducers, Flanges Etc. ) With Gc Check Cladding Above Insulation All As Per Specifications. 10 ) Structural Steel For Supporting Manifold. 11 ) Reducer + Flanges And Along With All Acessories To Installed Control Valve. , 100 Mm Ø , 50 Mm Ø , 32 Mm Ø , 25Mm Ø , Supply And Installation Of Condensate Drain Piping With 19 Mm Nitrile Rubber Insulation Rigid Gi Pipes With U-Trap And Fittings. , 80 Mm Ø , 40 Mm Ø , 25 Mm Ø , Supply And Installtion Of Rubber Bellows For Pumps In The Piping For Vibration Isolation At The Pumpsinlet & Outlet Connections. , 125 Mm Ø , 100 Mm Ø , Gauges, Vents & Flow Switches , Water Flow Switches , Auto Air Vents , Pressure Gauges 0-7Kg / Cm2 , Temperature Gauge 0-500C & 0-1000C , Hot Water Piping Supplying, Laying / Fixing, Testing And Commissioning Of Following Nominal Sizes Of Hot Water Piping Plumbing Inside The Building ( With Necessary Clamps, Supports, Vibration Isolators And Fittings But Excluding Valves, Strainers, Gauges Etc. ) Duly Insulated With Fire Retardant Quality Expanded Polystrene Moulded Pipe Section Of Density 20 Kg / Cu.M After A Thick Coat Of Cold Setting Adhesive ( Cprx Compound ) Wrapping With 500G Polythene Faced Hessain And Finally Applying 0.63Mm Aluminium Sheet Cladding Complete With Type3 , Grade 1 Roofing Feltstrip ( As Per Is:1322 As Amended Up To Date ) At Joints Repairing Of Damage To Building Etc. As Per Specifications And As Required Complete In All Respect. Note:- The Pipes Of Sizes 150Mm & Below Shall Be M.S. C Class As Per Is : 1239 And Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is: 3589, From Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350 Mm Dia. , 100Mm Dia. ( 50Mm Thick Insulation ) , 80Mm Dia. ( 50Mm Thick Insulation ) , 50Mm Dia. ( ( 50Mm Thick Insulation ) , 40Mm Dia. ( 50Mm Thick Insulation ) , 25 Mm Dia ( 50Mm Thick Insulation ) , Valves & Instrumentssitc Of Butterfly Valves, Required For Hot Waterpiping Including Necessary Mating Flanges, Gaskets, Bolt & Nuts And Insulation As Mentioned Above. , 80 Mm Ø , 50 Mm Ø , Sitc Of Ball Valves Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 25 Mm Ø , Sitc Of Manual Balancing Valves Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 50 Mm Ø , Sitc Of Nrvs Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 80 Mm Ø , Sitc Of Y- Strainers Including Necessary Mating Flanges, Gaskets, Bolt& Nuts And Insulation As Mentioned Above. , 80 Mm Ø , Sitc Fabricatedhotwater Manifoldfor Ahus As Below Having Hw Requirement For Hw Pipe Size As Below Comprising Of 1 ) 8 Rmt Of Ms Erw C Class Pipe As Per Is 1239 With All Necessary Fittings I.E. Bends, Reducers, Flanges Etc. 2 ) 5 Nos. Ball Valve / Butterfly Valve 3 ) 1 No. 2-Modulating Control Valve 3 ) 1 No. Balancing Valve 4 ) 1 No. Y Strainerscrewed / Flanged End. 5 ) 2 Nos. Pressure Gauges ( 1 In Supply Line & 1 In Return Line ) 6 ) 2 Nos. Temperature Gauges With Thermowell ( 1 In Supply Line & 1 In Return Line ) 7 ) 1 No. Auto Air Vent Valve Of Size 15Mm 8 ) 1 No. Drain Valve Of Size 25Mm 9 ) Insulation As Mentioned Above For The Manifold Pipe & Valve.Insulation To Be Provided Complete For Fittings ( Valves, Bends, Tees, Reducers, Flanges Etc. ) With Gc Check Cladding Above Insulation All As Per Specifications. 10 ) Structural Steel For Supporting Manifold. 11 ) Reducer + Flanges And Along With All Acessories To Installed Control Valve. , 40 Mm Ø , 32 Mm Ø , 25Mm Ø , Supply And Installation Of Condensate Drain Piping With 19 Mm Nitrile Rubber Insulation Rigid Gi Pipes With U-Trap And Fittings. , 25 Mm Ø , Supply And Installtion Of Rubber Bellows For Pumps In The Piping For Vibration Isolation At The Pumpsinlet & Outlet Connections. , 80 Mm Ø , Gauges, Vents & Flow Switches , Water Flow Switches , Auto Air Vents , Pressure Gauges 0-7Kg / Cm2 , Temperature Gauge 0-500C & 0-1000C , Hvac Low Side Items - Air Handling Unit -Recirculation Type Ahu For Classified Systems ( Iso-7 ) . - Sitc Of Floormountedhorizontaltypeairhandlingunit.Sheetmetalsectionalisedcabinettypeahuindoubleskin Construction Fabricated From Thermal Break Aluminium Extruded Section Frame Structure. The Inner Skin 0.8 Mm Gi & Outer Skin 0.8Mm Precoated Giconstruction With 43Mm Thick Puf Insulation Panel With Internal Coving And In Thermal Break Construction, Etc. Complete With Necessary Frame Work For Supporting Channels, Foundation Bolts And Completewith Followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & Returnair Damper , Fresh Air Module With Extruded Aluminium Low Leakage Type Manual Volume Control Damper With Filter. There Will Be Opening For Cable Entries For Humidity & Temp. Sensors In Mixing Chamber Section.Pre Filter, Microvee And Hepa Section Filter With Flange Type Filter Section With Combination Of Eu-4, Eu-5 Filters, H-13 ( 0.3? With 99.997% Efficiency ) Filters At Discharge End With Galvanised Stainless Steel ( Gss ) Frame With Section. 2 Bend Gss / Pvc Eliminators, Chilled Water Cooling Coil Section With6 Row Chilled Water Coil ( 20 Gauge Cu Tubes & 0.2Mm Thick Al Fins With Hydrophobic Coating ) Extruded Aluminium Low Leakage Manual By-Pass Damper Sandwich Type Insulated Drain Pan , Drain Pan Will Be 18G Ss 304 Construction.2Rowhot Watercoilsection ( 20 Gauge Cu Tubes & 0.2Mm Thick Al Fins With Hydrophobic Coating ) , Didw Blower Section With Kruger / Greenheck Amca Certified Make Blower With Antivibration Spring Isolators, Belt Driven Type , Tefc Fan Motor Of Efficiency Class Ie-3 Or More Suitable For 415 Volts, 50 Hz, 3 Phase Ip 55 Ac Supply Suitable For Vfd Application, & Mounted On Common Base Frame.Pvc Canvas Connectionat The Outlet Of The Fan. Bleed Air Module With, Extruded Aluminium Low Leakage Type Manual Volume Control Damper.Ahu Shall Be Supplied With Limit Switch, View Port, Marine Lamp And Necessory Internal Control Wiring.There Will Be Opening For Cable Entries For Motor In Section , Unit With Magnehelicgauges& Necessarytubingacrossthefilter.Theairhandlingunitsshouldhavealuminium Volume Control Dampers At Supply Air Outlet.There Will Be Access Door Across Every Section Of Ahu. , Ahu 02 - 13260 Cmh ( 7800 Cfm ) With 11Tr Cooling & 26.0Kw Heating Capacity @ 160 Sp ( Iso 7 ) With 2 Motor ( 1 W+1S ) , Ahu 03-16830 Cmh ( 9900 Cfm ) With 11Tr Cooling & 20.0Kw Heating Capacity @ 160 Sp ( Iso 7 ) With 2 Motor ( 1 W+1S ) , Ahu 04 -10200 Cmh ( 6000 Cfm ) With 9Tr Cooling & 12.0Kw Heating Capacity@ 160 Sp ( Iso 7 ) With 2 Motor ( 1 W+1S ) , Sitc Of Floormountedhorizontaltypeairhandlingunit.Sheetmetalsectionalisedcabinettypeahuindoubleskin Construction Fabricated From Thermal Break Aluminium Extruded Section Frame Structure. The Inner Skin 0.8 Mm Gi & Outer Skin 0.8Mm Precoated Giconstruction With 43Mm Thick Puf Insulation Panel With Internal Coving And In Thermal Break Construction, Etc. Complete With Necessary Frame Work For Supporting Channels, Foundation Bolts And Completewith Followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & Returnair Damper , Fresh Air Module With Extruded Aluminium Low Leakage Type Manual Volume Control Damper With Filter. There Will Be Opening For Cable Entries For Humidity & Temp. Sensors In Mixing Chamber Section.Pre Filter, Microvee Section Filter With Flange Type Filter Section With Combination Of Eu-4, Eu-5 Filtersfilters At Discharge End With Galvanised Stainless Steel ( Gss ) Frame With Section. 2 Bend Gss / Pvc Eliminators, Chilled Water Cooling Coil Section With6 Row Chilled Water Coil ( 20 Gauge Cu Tubes & 0.2Mm Thick Al Fins With Hydrophobic Coating ) Extruded Aluminium Low Leakage Manual By-Pass Damper Sandwich Type Insulated Drain Pan , Drain Pan Will Be 18G Ss 304 Construction.2Rowhot Watercoilsection ( 20 Gauge Cu Tubes & 0.2Mm Thick Al Fins With Hydrophobic Coating ) , Didw Blower Section With Kruger / Greenheck Amca Certified Make Blower With Antivibration Spring Isolators, Belt Driven Type , Tefc Fan Motor Of Efficiency Class Ie 3 Or More Suitable For 415 Volts, 50 Hz, 3 Phase Ip 55 Ac Supply Suitable For Vfd Application, & Mounted On Common Base Frame.Pvc Canvas Connectionat The Outlet Of The Fan. Bleed Air Module With, Extruded Aluminium Low Leakage Type Manual Volume Control Damper.Ahu Shall Be Supplied With Limit Switch, View Port, Marine Lamp And Necessory Internal Control Wiring.There Will Be Opening For Cable Entries For Motor In Section , Unit With Magnehelicgauges& Necessarytubingacrossthefilter.Theairhandlingunitsshouldhavealuminium Volume Control Dampers At Supply Air Outlet.There Will Be Access Door Across Every Section Of Ahu. , Ahu 01 - 6120 Cmh ( 3600 Cfm ) With 5.0Tr Cooling & 7.0Kw Heating Capacity@ 120 Sp ( Iso 8 ) With 2 Motor ( 1 W+1S ) , Ahu 06 - 1700 Cmh ( 1000 Cfm ) With 2.0Tr Cooling & 3.0Kw Heating Capacity @ 120 Sp ( Iso 8 ) With 2 Motor ( 1 W+1S ) , Ahu 07 - 11900 Cmh ( 7000 Cfm ) With 9.0Tr Cooling@ 100 Sp With 2 Motor ( 1 W+1S ) - ( Qa Qc Area ) , Once Through Type Ahu- Sitc Of Floormountedhorizontaltypeairhandlingunit.Sheetmetalsectionalisedcabinettypeahuindoubleskin Construction Fabricated From Thermal Break Aluminium Extruded Section Frame Structure. The Inner Skin 0.8 Mm Gi & Outer Skin 0.8Mm Precoated Giconstruction With 43Mm Thick Puf Insulation Panelwith Internal Coving And In Thermal Break Construction, Etc. Complete With Necessary Frame Work For Supporting Channels, Foundation Bolts And Completewith Followingsectionwithextrudedaluminiumlowleakagetypemanualsupply & Returnair Damper , Fresh Air Module With Extruded Aluminium Low Leakage Type Manual Volume Control Damper With Filter. There Will Be Opening For Cable Entries For Humidity & Temp. Sensors In Mixing Chamber Section.Pre Filter, Microvee And Hepa Section Filter With Flange Type Filter Section With Combination Of Eu-4, Eu-5 Filters, H-13 ( 0.3? With 99.997% Efficiency ) Filters At Discharge End With Galvanised Stainless Steel ( Gss ) Frame With Section. 2 Bend Gss / Pvc Eliminators, Chilled Water Cooling Coil Section With6 Row Chilled Water Coil ( 20 Gauge Cu Tubes & 0.2Mm Thick Al Fins With Hydrophobic Coating ) Extruded Aluminium Low Leakage Manual By-Pass Damper Sandwich Type Insulated Drain Pan , Drain Pan Will Be 18G Ss 304 Construction.2Rowhot Watercoilsection ( 20 Gauge Cu Tubes & 0.2Mm Thick Al Fins With Hydrophobic Coating ) , Didw Blower Section With Kruger / Greenheck Amca Certified Make Blower With Antivibration Spring Isolators, Belt Driven Type , Tefc Fan Motor Of Efficiency Class Ie3 Or More Suitable For 415 Volts, 50 Hz, 3 Phase Ip 55 Ac Supply Suitable For Vfd Application, & Mounted On Common Base Frame.Pvc Canvas Connectionat The Outlet Of The Fan. Bleed Air Module With, Extruded Aluminium Low Leakage Type Manual Volume Control Damper.Ahu Shall Be Supplied With Limit Switch, View Port, Marine Lamp And Necessory Internal Control Wiring.There Will Be Opening For Cable Entries For Motor In Section , Unit With Magnehelicgauges& Necessarytubingacrossthefilter.Theairhandlingunitsshouldhavealuminium Volume Control Dampers At Supply Air Outlet.There Will Be Access Door Across Every Section Of Ahu. , Ahu 05 -13090 Cmh ( 7700 Cfm ) With 45Tr Cooling & 41.0Kw Heating Capacity@ 160 Sp ( Iso 7 ) With 2 Motor ( 1 W+1S ) , Exhaust Unit- Floor Mounted Horizontal Type Exhaust Unit. Sheet Metal Sectionalised Cabinet Type Ahu In Double Skin Construction Fabricated From Thermal Break Aluminium Extruded Section Frame Structure. The Inner Skin 0.63 Mm Gi & Outer Skin 0.63Mm Precoated Giconstruction With 25Mm Thick Puf Insulation Panel, Suitable 20 Micron Filter, Blower And Motor, Exhaust Damper, Vibration Mounts Etc With All Necessary Hardware. , Veu 05 - 13430 Cmh ( 7900 Cfm ) @ 75Sp Motor: ( 1 W+1S ) , Chilled Water Cassette / Hi Wall Unit - Sitc Of Chilled Water Cassette Unit Withinfrared Remote Control, Micro-Controller, Drain Pump & Necessary Supporting Arrangement With Ready Made Valve Station Complete With Butterfly Valves / Gate Valves , 2 Way Valves With Actuators–Strainer, Pressure Cum Balancing Valves. The Entire Skid Shall Be Coated With Zinc-Chromate Primer Coating And Then Painted With Enamel Paint.Electrical Cable Connection From Mcb / Isolatorto Cassette Unitshall Be Done By Hvac Contractor. , 1.0Tr ( Cabin And Passagearea ) , 3.0Tr ( Office Area ) , Decorative Fcu: Chilled Water Fan Coil Unit Of Double Skin Construction With Compact Cooling Coil, Multispeed Fan Motor, The Blower Shall Be Dynamicaly Balanced And Designed For Silent Operation, The Filters Shall Be Washable Synthetic Media Type Arranged For Convenient Cleaning And Replacement, Drain Pan With Pump . The Actuator Of Modulating Valve Shall Be Provided With Interface Cards To Receive 0-10V Or 4-20 Ma Signal From Minxon Digital Thermostat. Unit Complete With All Necassary Valves.The Unit Is Supplied With Corded Remote Controller Of Approved As Per Instruction And As Directed By Oic-Es , 2.0Tr ( For Ups And Battery Room ) ( 1W+1S ) , 1.0Tr ( For Storageroom ) , Air Filtration System - Hooded Type Hepa Filters - Supply Of Hepa Filter Modules With Ss 304 Supplyperforated Grill In Crca Powder Coated Finish Side Inlet Type, With Provision For Dop, Pressure Drop Measurement Along With Volume Control Damper And Provision For A Flange Type Hepa Filters ( Hepa Filterh14 Type ) Including Flexible Connection. Price Also Include The Hepa Filter. , Size: 610 X 610 X150 Mm , Size: 450 X 450X150 Mm , Size: 305 X 305X150 Mm , Supply, Installation, Testing & Commissioning Of 25Mm Thick Thermal Insulated Aluminium Flexible Duct Of250mm Dia Duly Supported At Regular Interval As Per Site Requirement Etc. Complete As Required As Per Specifications. , Air Distribution And Control System - Ducting - Supply, Fabrication, Installation And Testing Of Following Sizes Of Aluminium Metal Ductingaluminium Supports, Angle Iron Flanges For All Sizes Of Ducts, Neoprene Gaskets For All Transverse Joints, Splitter Dampers, Tees, Reducers, Elbows Etc. The Frame Shall Slide Over The Duct Ends To Form Flange Connection. The Flange Connection Shall Be Supplied With Airtight Seals. Ducts Shall Be Suitably Reinforced Using Diagonal Bends, Distance Pieces, Etc.Apermanentnon-Etching, Siliconefreeelasticsealingmaterialshallbeused.Exposed Duct Should Have Provide Al. Cladding.Duct Leak Test To Carry Out After Instalttion. , 22 G Sheet , 20 G Sheet , 18 G Sheet , Insulation , Supplying And Fixing Of Following Thickness Duly Laminated Aluminum Foil Of Mat Finish Closed Cell Nitrile Rubber ( Class O ) Insulation On Existing Duct After Applying Suitable Adhesive For Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide And 3Mm Thick Self Adhesive Nitrile Rubber Tape Insulation Complete As Per Specifications And As Required. Exposed Duct Should Beprovide With 26 G Al Cladding. , 32 Mm Thick On Supply Air Duct , 19 Mm Thick On Return Air Duct , Supply Installation Of Aluminium Extruded Powder Coatedvolume Control Damper Constructed In 18G Gi Frame And 18G Blades Complete With Handle For Main And Branch Ducts. , Al.Sq.Fourwaytypeairdiffuser ( Supply&Return ) With18g, G.I. Powdercoatedboxwithaluminumcollar Damper: , Miscellaneousitems , Fire Damper: Supplying, Fixing, Testing And Commissioning Of Fire Dampers In Supply Air Duct / Main Branch And Return Air Path As And Where Required Of Required Sizes I / C Control Wiring, The Damper Shall Be Motorized And Spring Return So As To Close The Damper In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The Damper Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. , Fire Damper , Actuator , Supply Grills , Supplying & Installtion Of Perorated Type Grill For Return Air Riser With 1.2Mm Thick Gipc Capsulation Perforations With All Necessary Fixing Arrangement. , Gi Powder Coated Fresh Air Louvre With Filterand Brid Screen , Room Magnehelic Gauge ( -50 To 50 Pa ) , Magnehelicgaugeswithms Powder Coatedbox Andss Topcover Completewith Necessarytubing Withprobe To Measure The Differential Pressure Acroos The Rooms , Room Magnehelic Gauge ( -50 To- 50 Pa ) , Magnehelicgaugeswithms Powder Coatedbox Andss Topcover Completewith Necessarytubing Withprobe To Measure The Differential Pressure Acroos The Ahus. , On-Site Validation And Testing Of The Complete Clean Room System:After Completion Of E&C Of All Equipment And Accessories, Validation Test Shall Be Conducted As Described Below: Testing & Validation As Per Iso 14644:2001 Standards ( Velocity, Particulate Count, Temp, Humidity, Filter, Integrity Tests To Be Carried Out At The Site ) By 3Rd Party. A Comprehensive On-Site Validation And Certification Service For Clean Room Installation Is In The Scope. These Includes Leak Detection, Clean Room Level Measurement And Certification, Air Flow Pattern Analysis, Dead Zone Identification And Elimination And Comprehensive Documentation With Regard To Maintenance & Validation Procedure. , Followingvalidation&Testingoftheinstalledclean-Roomduringfinalcommissioningoftheabovecleanroom Project: Cleanliness Levels As Per Iso 14644 Air Quality Monitoring Particle Size Efficiencies And Quantity Count Airborne Particulate Contamination Monitoring Air Velocity Measurement & Air-Flow Quantity Measurement Temperature Control Range Tests Humidity Control Range Tests Filter Pressure Drop Measurements Air Flow Pattern And Strength Light Level Checks At 1M Working Height In Clean Room Room Pressurization , 1 Year Warranty Is Included In The Above Items. Cmc Including All Spare For The 6 Years After Warantee Period For Hvac System. , 2Nd Year Cmc After Handing Over The Project , 3Rd Year Cmc After Handing Over The Project , 4Th Year Cmc After Handing Over The Project , 5Th Year Cmc After Handing Over The Project , 6Th Year Cmc After Handing Over The Project , 7Th Year Cmc After Handing Over The Project , Gas Distribution System , Supply And Installtion Of High Pressure Gas Manifold System ( Manual ) For Four Cylinders For Co2 Gas With All Necessary Fitting , Hardware Etc As Per The Requirement.- Ss 304 , Sitc Of Automatic Control Panel To Transfer Co2 Between The Manifold. , Supply And Installtion Of High Pressure Gas Manifold System ( Manual ) For Two Cylinders For Co2 Gas With All Necessary Fitting , Hardware Etc As Per The Requirement.- Ss 304 , 1 / 2 Ss 316L Tube With Necessary Fittings And Supports - Ss 316L , 1 / 4 Ss 316L Tube With Necessary Fittings And Supports - Ss 316L , 1 / 2 Ball Valvess 316L , 1 / 4 Ball Valve Ss 316L , Sitc Of Gas Control Box With Gauge Regulator, Needle Valveand All Other Necessary Fillting, Hadware Etc As Per The Requirement. , Sitc Of Pvc Tube With Brass Nozzle For Providing The Connection Inside The Lab With All Necassry Hadware, Fitting Etc As Per Instruction And As Directed By Oic-Es , 1 Year Warranty Is Included In The Above Items. Cmc Including All Spare For The 6 Years After Warantee Period For Gas Distribution System. , 2Nd Year Cmc After Handing Over The Project , 3Rd Year Cmc After Handing Over The Project , 4Th Year Cmc After Handing Over The Project , 5Th Year Cmc After Handing Over The Project , 6Th Year Cmc After Handing Over The Project , 7Th Year Cmc After Handing Over The Project , Cat ( B ) - Supply, Installation, Testing And Commissioning Of Following Equipment As Per Tendered Specifications Of Cgmp Centre Of Cellular Immunotherapies At Actrec , Lab Refrigerator – 625 Ltsas Per Tendered Specifications , Clean Room Lab Refrigerator – 625 Ltsas Per Tendered Specifications , Blood Bank Refrigerator Customized -625 Lts As Per Tendered Specifications , Automated Closed Cell Processing System As Per Tendered Specifications , Cell Expansion System As Per Tendered Specifications , Mobile Processing System Ready Kart As Per Tendered Specifications , Controlled Freeze System ( Rate Controlled Freezer ) As Per Tendered Specifications , Blood Bag Centrifuge – 8 Bags As Per Tendered Specifications , Water Bath High Precision As Per Tendered Specifications , Automated Thawer For Bags As Per Tendered Specifications , Bsl Cabinet - 6 Ft Width X 7.5 Ft Height ( Length ) ( Bsl-2* ) As Per Tendered Specifications , Air Jacketed Co2 Incubator As Per Tendered Specifications , Automated Cell Counter As Per Tendered Specifications , Inverted Microscope As Per Tendered Specifications , Inverted Microscope As Per Tendered Specifications , Floor Model High Speed Centrifuge ( Bags & Vials ) As Per Tendered Specifications , 100 Ltr Refrigerator As Per Tendered Specifications , Sterile Connecting Device Type Aas Per Tendered Specifications , Sterile Connecting Device Type Bas Per Tendered Specifications , Hand Sealeras Per Tendered Specifications , Magnetic Based Cell Separation System -Cts Grade Dynamagnet As Per Tendered Specifications , Bench Top Minispin As Per Tendered Specifications , High Performance Centrifuge For Elutriationas Per Tendered Specifications , Table Top Model High Speed Centrifuge As Per Tendered Specifications , Bsl Cabinet - ( Bsl-2* ) As Per Tendered Specifications , Ultracentrifuge As Per Tendered Specifications , Bench Top Centrifuge As Per Tendered Specifications , Microplate Spectrophotometer As Per Tendered Specifications , Real Time Pcr As Per Tendered Specifications , Gel Dock System As Per Tendered Specifications , End Point Pcr Proflex As Per Tendered Specifications , Flow Cytometer -Facs Cell Sorteranalyzer As Per Tendered Specifications , Endotoxin Detection System As Per Tendered Specifications , Liquid Nitrogen Tank-Bags As Per Tendered Specifications , Liquid Nitrogen Tank-Vials As Per Tendered Specifications , Deep Freezer-80 Cas Per Tendered Specifications , Deep Freezer -20 To -40 C As Per Tendered Specifications , Deep Freezer -20 C As Per Tendered Specifications , Deep Freezer-80 C As Per Tendered Specifications , Cryoshipper As Per Tendered Specifications , Cat ( C ) - Cmc After Expiry Of Warranty Period For Following Equipment , Lab Refrigerator – 625 Lts- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Lab Refrigerator – 625 Lts- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Lab Refrigerator – 625 Lts- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Lab Refrigerator – 625 Lts- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Lab Refrigerator – 625 Lts- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Clean Room Lab Refrigerator – 625 Lts - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Clean Room Lab Refrigerator – 625 Lts - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Clean Room Lab Refrigerator – 625 Lts - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Clean Room Lab Refrigerator – 625 Lts - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Clean Room Lab Refrigerator – 625 Lts - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Blood Bank Refrigerator Customized -625 Lts- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Blood Bank Refrigerator Customized -625 Lts- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Blood Bank Refrigerator Customized -625 Lts- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Blood Bank Refrigerator Customized -625 Lts- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Blood Bank Refrigerator Customized -625 Lts- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Automated Closed Cell Processing System- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Automated Closed Cell Processing System- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Automated Closed Cell Processing System- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Automated Closed Cell Processing System- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Automated Closed Cell Processing System- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Cell Expansion System- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Cell Expansion System- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Cell Expansion System- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Cell Expansion System- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Cell Expansion System- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Mobile Processing System Ready Kart- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Mobile Processing System Ready Kart- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Mobile Processing System Ready Kart- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Mobile Processing System Ready Kart- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Mobile Processing System Ready Kart- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Controlled Freeze System ( Rate Controlled Freezer ) - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Controlled Freeze System ( Rate Controlled Freezer ) - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Controlled Freeze System ( Rate Controlled Freezer ) - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Controlled Freeze System ( Rate Controlled Freezer ) - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Controlled Freeze System ( Rate Controlled Freezer ) - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Blood Bag Centrifuge – 8 Bags - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Blood Bag Centrifuge – 8 Bags - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Blood Bag Centrifuge – 8 Bags - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Blood Bag Centrifuge – 8 Bags - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Blood Bag Centrifuge – 8 Bags - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Water Bath High Precision- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Water Bath High Precision- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Water Bath High Precision- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Water Bath High Precision- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Water Bath High Precision- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Automated Thawer For Bags- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Automated Thawer For Bags- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Automated Thawer For Bags- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Automated Thawer For Bags- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Automated Thawer For Bags- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - 6 Ft Width X 7.5 Ft Height ( Length ) ( Bsl-2* ) - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - 6 Ft Width X 7.5 Ft Height ( Length ) ( Bsl-2* ) - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - 6 Ft Width X 7.5 Ft Height ( Length ) ( Bsl-2* ) - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - 6 Ft Width X 7.5 Ft Height ( Length ) ( Bsl-2* ) - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - 6 Ft Width X 7.5 Ft Height ( Length ) ( Bsl-2* ) - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Air Jacketed Co2 Incubator- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Air Jacketed Co2 Incubator- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Air Jacketed Co2 Incubator- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Air Jacketed Co2 Incubator- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Air Jacketed Co2 Incubator- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Automated Cell Counter – 625 Lts- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Automated Cell Counter - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Automated Cell Counter - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Automated Cell Counter - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Automated Cell Counter - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type A- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type A- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type A- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type A- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type A- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type B- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type B- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type B- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type B- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Inverted Microscope Type B- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Floor Model High Speed Centrifuge ( Bags & Vials ) - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Floor Model High Speed Centrifuge ( Bags & Vials ) - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Floor Model High Speed Centrifuge ( Bags & Vials ) - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Floor Model High Speed Centrifuge ( Bags & Vials ) - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Floor Model High Speed Centrifuge ( Bags & Vials ) - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , 100 Ltr Refrigerator- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , 100 Ltr Refrigerator- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , 100 Ltr Refrigerator- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , 100 Ltr Refrigerator- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , 100 Ltr Refrigerator- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type A- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type A- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type A- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type A- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type A- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type B- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type B- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type B- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type B- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Sterile Connecting Device Type B- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Hand Sealer- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Hand Sealer- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Hand Sealer- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Hand Sealer- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Hand Sealer- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Magnetic Based Cell Separation System -Cts Grade Dynamagnet- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Magnetic Based Cell Separation System -Cts Grade Dynamagnet- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Magnetic Based Cell Separation System -Cts Grade Dynamagnet- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Magnetic Based Cell Separation System -Cts Grade Dynamagnet- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Magnetic Based Cell Separation System -Cts Grade Dynamagnet- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Bench Top Minispin- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Bench Top Minispin- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Bench Top Minispin- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Bench Top Minispin- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Bench Top Minispin- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , High Performance Centrifuge For Elutriation - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , High Performance Centrifuge For Elutriation - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , High Performance Centrifuge For Elutriation - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , High Performance Centrifuge For Elutriation - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , High Performance Centrifuge For Elutriation - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Table Top Model High Speed Centrifuge- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Table Top Model High Speed Centrifuge- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Table Top Model High Speed Centrifuge- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Table Top Model High Speed Centrifuge- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Table Top Model High Speed Centrifuge- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - ( Bsl-2* ) - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - ( Bsl-2* ) - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - ( Bsl-2* ) - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - ( Bsl-2* ) - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Bsl Cabinet - ( Bsl-2* ) - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Ultracentrifuge- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Ultracentrifuge- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Ultracentrifuge- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Ultracentrifuge- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Ultracentrifuge- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Bench Top Centrifuge- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Bench Top Centrifuge- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Bench Top Centrifuge- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Bench Top Centrifuge- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Bench Top Centrifuge- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Microplate Spectrophotometer- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Microplate Spectrophotometer- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Microplate Spectrophotometer- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Microplate Spectrophotometer- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Microplate Spectrophotometer- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Real Time Pcr- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Real Time Pcr- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Real Time Pcr- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Real Time Pcr- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Real Time Pcr- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Gel Dock System- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Gel Dock System- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Gel Dock System- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Gel Dock System- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Gel Dock System- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , End Point Pcr Proflex- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , End Point Pcr Proflex- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , End Point Pcr Proflex- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , End Point Pcr Proflex- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , End Point Pcr Proflex- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Flow Cytometer -Facs Cell Sorteranalyzer- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Flow Cytometer -Facs Cell Sorteranalyzer- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Flow Cytometer -Facs Cell Sorteranalyzer- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Flow Cytometer -Facs Cell Sorteranalyzer- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Flow Cytometer -Facs Cell Sorteranalyzer- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Endotoxin Detection System- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Endotoxin Detection System- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Endotoxin Detection System- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Endotoxin Detection System- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Endotoxin Detection System- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Bags - Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Bags - Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Bags - Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Bags - Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Bags - Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Vials- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Vials- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Vials- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Vials- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Liquid Nitrogen Tank-Vials- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 To -40 C- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 To -40 C- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 To -40 C- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 To -40 C- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 To -40 C- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 C- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 C- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 C- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 C- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer -20 C- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Deep Freezer-80 C- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years , Cryoshipper- Cmc For 1St Year After Expiry Of Warranty Period Of 2 Years , Cryoshipper- Cmc For 2Nd Year After Expiry Of Warranty Period Of 2 Years , Cryoshipper- Cmc For 3Rd Year After Expiry Of Warranty Period Of 2 Years , Cryoshipper- Cmc For 4Th Year After Expiry Of Warranty Period Of 2 Years , Cryoshipper- Cmc For 5Th Year After Expiry Of Warranty Period Of 2 Years