Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | 1) Civil Works (Auditorium Hall):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 2 | 1.3: Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
| 3 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL(ii)Super Ductile (SD) TMT reinforcement bars |
| 4 | 18.3.1.:- Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998 |
| 5 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 6 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3 |
| 7 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3 |
| 8 | 2.1.3:- Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. |
| 9 | 3.1.1:- Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:3.1.1.1:- Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.(a) Using 38mm thick plank |
| 10 | 3.1.1.2:- Sides of tie beams, grade beams etc. at or below ground level.(a) Using 38mm thick plank |
| 11 | 3.1.1.3:- Columns, Pillars, Posts & Strut(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face(i) Using 38mm thick plank |
| 12 | 3.1.1.4:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M.(i) Using 38mm thick plank |
| 13 | 3.1.1.5:- Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.(a) Floors etc. upto 200mm in thickness.(i) Using 38mm thick plank |
| 14 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 15 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessary(b) In proportion 1:4. |
| 16 | 4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately)(A) 112mm thick brick wall(a) In cement mortar in proportion 1:4. (1 cement:4 sand) |
| 17 | 11.2.2:- Providing,fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 63mm x 38mm x 2.5mm section of approved brand with door style of size 50mm x 45mm x 2.0mm, top rails 50mm x 45mm x 2.5mm, middle rail 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels.(iii) 6mm coloured reflectory glass |
| 18 | 11.1.4:- Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.(b)3 Track sliding window(iii)6mm coloured glass |
| 19 | 5.1.4:- 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. |
| 20 | 6.2.1:- 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises orrounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.b) In cement mortar 1:4 |
| 21 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.B) On fair sideb) In cement mortar 1:4 |
| 22 | 6.2.3:- 20 mm thick Cement plaster in two coats on single or half brickwalls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick)b) In cement mortar 1:4 |
| 23 | 8.1.33:- Providing Pre Painted Galvanized IronSheetRoofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement(iv) 0.60 mm thick |
| 24 | 8.1.34:- Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing)at all levels including fitting and fixing self drilling, self tapping screws complete complete.TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement(iv) 0.60 mm thick |
| 25 | 7.2.3:- Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) pre-coated G.I. angle size 24mmx24mmx80mm thick fixed to the brick wall/ partition at the perimeter of ceiling with nylon sleeves and screws, at 610mm c/c. Then suspending main \"T\" section (bottom pre-coated) size 24mmx38mmx0.70mm and 3600mm long from the soffit in one direction with the help of metal Rawl Plug. Soffit cleat and G.I. Rod 4mm diameter with galvanised level clip 1220mm c/c G.I. cross (E) BPB Grid ceiling system with P.V.C. laminated crack Gypboard (Polyshield-C) Tiles 9.5mm thick. |
| 26 | 19.2:- Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. |
| 27 | 26.1.2:- Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. |
| 28 | 10.2:- Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws.IIOrnamental grill(c) Fixed to Brickwork/P.C.C/R.C.C. |
| 29 | 15.2.1:- Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) |
| 30 | 5.4.3:- Supplying, fitting and fixing 38mm thick (finished size) wooden flooring with sal wood plank butt jointed, fitted on sal wood joist of size 100mm x 125mm spaced not more than 900mm apart fitted with 16mm dia bolt and nuts with iron clamp of 50mm x 5mm size inserting in the cement concrete floor base (floor base to be measured and paid separately) including providing 25mm thick damp proof course with water proofing compound as recommended by the manufacturer over C.C floor base including providing kiricide oiling two coats to the timber joists, underside of the flooring planks, two coats of anti-corrosive paint to the iron works, including providing ventilation gaps for the timber works of specified size (75mm x 75mm) covered with welded mesh fabrics at the face of the gap including dressing, levelling, finishing complete as specified and directed by the department at all levels (measurement shall be taken at the finished area of the works). |
| 31 | 1.4:- Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.(b) Other than Guwahati city |
| 32 | 5.7.2.1:- Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)c) Delux range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Makei) Of size 1000mmx1000mm and above |
| 33 | 5.7.2.1:- Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).c) Delux rangeSomany/ Orient/Nitco/Varmora Makeiv) Of size 300mmx600mm and above |
| 34 | 13.6.3:- Applying priming coat over newwood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white). |
| 35 | 13.6.5:- Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.(i).Surfaces over 100mm in width or girth.b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). |
| 36 | 13.7.2:- Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.a). With ready mixed \"red-lead/ red oxide\" primer. |
| 37 | 13.7.4:- Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(i).Surfaces over 100mm in width or girth.b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). |
| 38 | 13.3.4:- Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)(i) Thickness = 1.5 mm thick |
| 39 | 13.3.1:- Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. |
| 40 | 13.4.1:- Wall painting (two coats) with acrylic emulsion paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.(a).Acrylic Emulsion Paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) |
| 41 | 31.2:- Supplying, fitting and fixing SoundSoak FSS Cordura wrapped acoustical wall panel system of Anutone Acoustics Ltd. Including all fixtures and fittings.b) 25 MM |
| 42 | 31.14.2:- Providing & fixing Armstrong Mineral fibre Acoustical suspended ceiling system with beauty sky ( board/tegular) edge tiles with armstrong 24mm exposed grid (600x600x15)mm |
| 43 | 2) Furniture:Supplying fitting and fixing sitting arrangement for fixed Chairs. |
| 44 | Supplying fitting and fixing VIP Chair for waiting room 2 Nos. with Teak Wood. |
| 45 | Supplying fitting and fixing VIP Table for waiting room 2 Nos. with Teak Wood. |
| 46 | Supplying fitting and fixing Dining Table with Teak wood 50 Nos. Capacity. |
| 47 | Supplying fitting and fixing Dining Chair with Teak wood. |
| 48 | 3) Civil Works (Kitchen):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 49 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 50 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 51 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b)Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.(a) 12mm dia |
| 52 | 3.2.1.:- Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face |
| 53 | 3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M. |
| 54 | 3.2.1.3:- Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.(a) Floors etc. upto 200mm in thickness. |
| 55 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3 |
| 56 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3 |
| 57 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessaryb) In prop. 1:4(a) Waiting Hall |
| 58 | 1.3:- Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
| 59 | 2.1.3:- Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. |
| 60 | 4.1.7:- 112mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above P.L. up to 1st floor level.(a) In cement mortar in proportion 1:4 (1cement:4sand) |
| 61 | 18.7.2:- Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).(ii) Size 105mm x 60mm (Single rebate) |
| 62 | 18.3.1:- Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.b) Using other ISI marked approved circular hollow section |
| 63 | 8.1.7:- Providing 0.63 mm thick(24 gauge) galvd plain sheet in valley , lining, flashing etc. and fitted with gavd. Iron J or L hook bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in a positions as directed. |
| 64 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a) Brick on flat Soling |
| 65 | 8.1.36:- Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing)at all levels including fitting and fixing self drilling, self tapping screws complete.TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departementiv) 0.55mm thick. |
| 66 | 8.1.35:- Providing Pre Painted Galvalume Sheet Roofing(PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (a) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departementiv) 0.55mm thick. |
| 67 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough sideb) In cement mortar 1:4 |
| 68 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.B) On fair sideb) In cement mortar 1:4 |
| 69 | 5.1.4:- 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. |
| 70 | 5.1.10:- Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.(b)20 mm thick |
| 71 | 7.10.1:- Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre CementBoard as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid.(A) Standard Ceilings of Everest make or equivalent as directed by the departement(ii) Using 6 mm thick FC Board |
| 72 | 9.4.1:- Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete. |
| 73 | 9.12.1:- Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core.(i) 40 mm thick . |
| 74 | 11.1.2:- Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.(a)2 Track sliding window(i)6mm clear glass |
| 75 | 15.21.1:- Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door boltsi) 300mm x 16mm |
| 76 | 15.21.1:- Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )b) Tower boltii) 250mm x 12mm |
| 77 | 15.21.1:- Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )c) Door handleii) 150mm |
| 78 | 15.21.1:- Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )d) Gate shutter hook & Eye(ii) 150mm |
| 79 | 10.2:- Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws.I. Plain(c) Fixed to Brickwork/P.C.C/R.C.C. |
| 80 | 13.6.3:- Applying priming coat over newwood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. (a). With ready mixed paint , Wood primer (pink) |
| 81 | 13.6.5:- Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.(i).Surfaces over 100mm in width or girth.b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). |
| 82 | 19.2:- Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. |
| 83 | 19.5:- Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. |
| 84 | 5.7.2.1- Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Makeii) Of size 600mmx600mm and above |
| 85 | 4) Civil Works (Parking Shed):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 86 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 87 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 88 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b)Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.(a) 12mm dia |
| 89 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) c)ISI approved M.S. rod strup for tie beam |
| 90 | 3.2.1.:- Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face |
| 91 | 3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M. |
| 92 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticisera) M15 grade concrete or Prop. 1:2:4 |
| 93 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticisera) M15 grade concrete or Prop. 1:2:4 |
| 94 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessaryb) In prop. 1:4 |
| 95 | 1.3:- Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
| 96 | 2.1.3:- Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. |
| 97 | 4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately)(A) 112mm thick brick wall(a) In cement mortar in proportion 1:4. (1 cement:4 sand) |
| 98 | 18.3.2:- Providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube |
| 99 | 8.1.36:- Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing)at all levels including fitting and fixing self drilling, self tapping screws complete.TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departementv) 0.55mm thick |
| 100 | 9.4.1:- Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete. |
| 101 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough sideb) In cement mortar 1:4 |
| 102 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.B) On fair sidea) In cement mortar 1:4 |
| 103 | 5.1.4:- 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. |
| 104 | 13.2.1:- a) Colour washing with lime on wall surface (two coats) over and including a priming coat of white washing to give an even shade after throughly brooming the surface to remove all dirt, dust, mortar drops and other foreign matter. |
| 105 | 26.1.1:- Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. |
| 106 | 26.1.2:- Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. |
| 107 | 26.1.3:- Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. |
| 108 | 19.2:- Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. |
| 109 | 19.5:- Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.i). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm. |
| 110 | 13.6.3:- Applying priming coat over newwood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white). |
| 111 | 13.6.5:- Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). |
| 112 | 5) Civil Works (Approach Road):-30.02:- Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.)(b)Using Grading II material |
| 113 | 30.4:- Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc.,and removal of the same for in-situ reinforced concrete and plain concrete work in R.C.C. approach road.(b) Using 25mm thick plank |
| 114 | 30.5:- Providing and laying controlled cement concrete pavement of approved grade with 20mm down graded stone aggregate over a prepared sub-base including dewatering if necessary, spread, compacted and finished in a continuous operation including provision of construction and expansion joints, plasticiser and curing compound of Fosroc/ Sika/ Choksey/ Degusa and hardener of Recron/ Degusa/ Fosroc; finishing to lines and grades and curing as specified and directedcomplete(form work and reinforcement shall be measured and paid separately). (a)M 20 Grade Concrete |
| 115 | 30.7:- Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD. |
| 116 | 6) Civil Works (Boundary Wall):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 117 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 118 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 119 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b)Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.(a) 12mm dia |
| 120 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) c)ISI approved M.S. rod strup for tie beam |
| 121 | 2.1.3:- Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. |
| 122 | 3.2.1.:- Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face |
| 123 | 3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M. |
| 124 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticisera) M15 grade concrete or Prop. 1:2:4 |
| 125 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticisera) M15 grade concrete or Prop. 1:2:4 |
| 126 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessaryb) In prop. 1:4 |
| 127 | 4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately)(A) 112mm thick brick wall(a) In cement mortar in proportion 1:4. (1 cement:4 sand) |
| 128 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough sideb) In cement mortar 1:4 |
| 129 | 13.2.3:- a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. |
| 130 | 13.2.3:- b) Finishing wall with water proofing cement paint of approvedbrand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials. |
| 131 | 7) Civil Works (Heavy Duty Iron Gate Double Leaf):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 132 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 133 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 134 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b)Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.(a) 12mm dia |
| 135 | 3.2.1.:- Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face |
| 136 | 3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M. |
| 137 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticisera) M15 grade concrete or Prop. 1:2:4 |
| 138 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticisera) M15 grade concrete or Prop. 1:2:4 |
| 139 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessaryb) In prop. 1:4 |
| 140 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough sideb) In cement mortar 1:4 |
| 141 | 13.2.3:- a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. |
| 142 | 13.2.3:- b) Finishing wall with water proofing cement paint of approvedbrand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials. |
| 143 | 17.11:- Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are tobe protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessarylocking arrangement on both faces, arrangement for temporary closing the gateand 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts). |
| 144 | 8) Earth Filling:1.4:- Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.(b) Other than Guwahati city |
| 145 | 9) Civil Works (RCC Stagging with Pump House Sand Filter & Reservoir):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 146 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 147 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 148 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL(ii)Super Ductile (SD) TMT reinforcement bars |
| 149 | 3.2.1:- Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face |
| 150 | 3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M. |
| 151 | 3.2.1.3:- Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.(a) Floors etc. upto 200mm in thickness. |
| 152 | 3.2.1.6:- Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like. |
| 153 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.b) M20 grade concrete or Prop. 1:1.5:3 |
| 154 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3 |
| 155 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessary(b) In proportion 1:4. |
| 156 | 4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately)(A) 112mm thick brick wall(a) In cement mortar in proportion 1:4. (1 cement:4 sand) |
| 157 | 1.3:- Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
| 158 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.B) On fair sideb) In cement mortar 1:4 |
| 159 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough sideb) In cement mortar 1:4 |
| 160 | 18.4.1:- Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint. |
| 161 | 10.2:- Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws.(c) Fixed to Brickwork/P.C.C/R.C.C. |
| 162 | 25.12:- Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire withnecessary shuttering , curing etc. completeincluding fixing in position as directed.a) 100mm thick slab |
| 163 | 13.7.2:- Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.a). With ready mixed \"red-lead/ red oxide\" primer. |
| 164 | 13.7.4:- Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(i).Surfaces over 100mm in width or girth.b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). |
| 165 | 13.9.3:- Finishingold/ new wall with water proofing weathercoat smooth anti-fungal premium textured exterior finish of Sandex Matt brand of Snowcem India Ltd. of required shadeafter clering and clearing the surfaces etc.including scaffolding complete as directed at alllevels (two coats). |
| 166 | 5.3.4:- Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.ii) Bore hole of 100mm diameter |
| 167 | 5.3.5:- Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.(I) G.I. pipe (a) TATA/ SAIL (Medium) socket should be welded to the pipes.iv) 100mm diameter. |
| 168 | 5.3.6:- Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.(I) G.I. pipe (a) TATA/ SAIL (Medium) socket should be welded to the pipes.ii) 32mm diameter. |
| 169 | 5.3.12:- Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained. |
| 170 | 5.3.13:- Flushing, clearing, washing and watering the tube well |
| 171 | 3.1.1:- Supplying, fitting and fixing G.I. pipes of following sizes, with all necessary \"R\" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified.(A) Exposed on walls(b) 40 mm ia (Medium) (i) Using TATA make |
| 172 | 3.1.1:- Supplying, fitting and fixing G.I. pipes of following sizes, with all necessary \"R\" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified.(A) Exposed on walls(d) 25 mm ia (Medium) (i) Using TATA make |
| 173 | 3.2.1:- Supplying, fitting and fixing C.P. bib cock 15mm dia of approved brand as directed and specified (G.I. & C.P. pipes will be measured separately)(II) Jaquare make (a) Continental/ Clarion (ii) Bibcock long thread. |
| 174 | 3.17.1:- Supplying and fitting gun metal country pit valve (full way valve) I.S.I. make as specified and directed.(b) 40 |
| 175 | 3.17.3:- Supplying fitting and fixing gun metal check valve including necessary threads to pipes.b) 40 mm dia (Heavy type) |
| 176 | 5.4.2:- Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Syntex/ Polycon/ Patton make over the stagging with manhole cover with locking arrangement including providing pads of size as required for inlet and outlet pipes.(i) 2000 Lt. capacity |
| 177 | 10) Civil Works (Wash room including Toilet):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 178 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 179 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 180 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL(i) TMT Corrosion resistant steel (CRS) reiforcement bar |
| 181 | 3.2.1.:- Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face |
| 182 | 3.2.1.2:- Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.(a) For depth not exceeding 1.0M. |
| 183 | 3.2.1.3:- Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.(a) Floors etc. upto 200mm in thickness. |
| 184 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3 |
| 185 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3 |
| 186 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessaryb) In prop. 1:4 |
| 187 | 1.3:- Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
| 188 | 2.1.3:- Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. |
| 189 | 4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately)(A) 112mm thick brick wall(a) In cement mortar in proportion 1:4. (1 cement:4 sand) |
| 190 | 2.1.2:- Plain cement concrete floor base in prop1:3:6 laid in alternatebays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick |
| 191 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough sideb) In cement mortar 1:4 |
| 192 | 13.3.1:- Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. |
| 193 | 13.3.2:- Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and externalafter removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 194 | 13.9.1:- Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) |
| 195 | 5.7.2.1:- Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Makea) Of size 600mmx600mm and above |
| 196 | 5.7.2.2:- Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).i) Of size 300mmx450mm and above |
| 197 | 9.9.3:- Providing, fitting and fixing factory made wooden panelleddoorswith panelinserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together withcontinoustongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x75 mm x3.55mm) and furnishing with moulded timber beading of size 25mmx15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately)a) With Teak wood / Sissuwood.(i)40 mm thick with panel inserts of 20mm thickness. |
| 198 | 9.9.9:- Providing, fitting and fixing fully glazed clerestory window and fan light including fitting and fixing 2 M.S pivot hinges (75mm x 20mm x 3mm), eye hook and nylon chord complete(glass panes shall be measured and paid separately) B) With Holock/Gamari/Bonsumwood.(ii) 35mm thick |
| 199 | 9.9.8:- Providing fitting and fixing fully glassed window without intermediate sash bars including oxidised M.S. Butt hinges…etc. |
| 200 | 10.2:- Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws.I .Plain grill(a) Fixed to wooden frames |
| 201 | 1.51:- Construction of filter bed in soakpit including earth work in excavation of soil and then filling up of the trench with brick bats/ charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed…etc. |
| 202 | 19.2:- Providing Plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. |
| 203 | 19.4:- Providing drain with cement concrete (1:3:6) 10cm from thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 …etc. |
| 204 | 16.2:- Providing and fixing plain frosted glass of ordinary glazing quality bedded in putty and fixed with/without wooden bidding including necessary cuttings….etc.b) 3.50mm thick. |
| 205 | 15.2.1:- Supplying, fitting and fixing anodised alluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects… etc. complete as directed.(a) Sliding Door Bolt.(ii) 250mm x 16mm |
| 206 | 15.2.1:- Supplying, fitting and fixing anodised alluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects… etc. complete as directed.(b) Tower Bolt(i) 250mm x12mm |
| 207 | 15.2.1:- Supplying, fitting and fixing anodised alluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects… etc. complete as directed.(c) Door Handle(ii) 150mm |
| 208 | 6.2.1:- Supplying and Placement ferrocement septic tank of rectangular shape into pit with man hole cover with cleaning arrangementVIII) 100 User |
| 209 | SATITARY FITTINGS AND WATER SUPPLY:6.2.1:- Supplying and Placement ferrocement septic tank of rectangular shape into pit with man hole cover with cleaning arrangementVIII) 100 User |
| 210 | 1.2:- Providing fitting and fixing vitreous china pedestal type water closet (European type W.C. pan 400mm high) with seat and lead….etc.(A) Parryware make(a) White(vi) Elite P Trap (Cat No.CO278) (Inclusive seat cover) |
| 211 | 1.8:- Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions etc. complete.A) Parryware make a) White ii) Aquaseal (Cat No.C0508) |
| 212 | 1.13:- Providing vitreous china wash basin with CI/MS brackets, CP brass chain with plug, PVC waste pipe including painting of fittings and brackets… etc.1.13.1:- PEDESTAL BASIN (with pedestal) (a)(ii) Vanice 620 x 485 x 850 (Cat No. C841 P/R) (white/coloured) |
| 213 | 1.18:- Providing fitting and fixing Mirror with plastic frame of size 500 x 400mm complete as directed and specified. |
| 214 | 1.21:- Providing, fitting and fixing recessed soap tray/soap dish complete as directed and specified.(b) Sona Make(i) Soap dish light (Cat No. TR-0661) |
| 215 | 1.24:-Providing, fitting and fixing CP towel rail complete as directed and specified.(b) Sona Make(i) Towel rail Diplomat 300mm long (Cat No. TR-0605) |
| 216 | 1.37.5:- Supplying, fitting and fixing PVC Plain single tee of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc.a) In exposed surfaces or in trenches(i) 110mm dia |
| 217 | 1.37.17:- Supplying, fitting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc.a) In exposed surfaces or in trenches(ii) 110mm dia |
| 218 | 1.38:- Providing, fitting and fixing 50mm dia HCI cowel with cement caulking complete as directed and specified. |
| 219 | 1.46:- Providing, fitting and fixing 450mm dia, 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified. |
| 220 | 1.52:- Construction of inspection pit inside measurement 450mm x 450mm x 450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base….etc. |
| 221 | 1.54:- Supplying, fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stabililty for hot and cold water supply…etc.i) In internal wall - exposed on wall.(f) 50mm OD |
| 222 | 1.54:- Supplying, fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stabililty for hot and cold water supply…etc.i) In internal wall - exposed on wall.(e) 40mm OD |
| 223 | 1.54:- Supplying, fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stabililty for hot and cold water supply…etc.i) In internal wall - exposed on wall.(d) 32mm OD |
| 224 | 1.54:- Supplying, fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stabililty for hot and cold water supply…etc.i) In internal wall - exposed on wall.(c) 25mm OD |
| 225 | 1.54:- Supplying, fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stabililty for hot and cold water supply…etc.i) In internal wall - exposed on wall.(b) 20mm OD |
| 226 | 1.54:- Supplying, fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stabililty for hot and cold water supply…etc.i) In internal wall - exposed on wall.(a) 15mm OD |
| 227 | 1.37.1:- Supplying, fitting and fixing PVC pipe of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. complete.a) Exposed Surfaces or in trenchesii) 110mm dia |
| 228 | 5.4.2:- Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex/Polycon/Patton make over the stagging with manhole cover with locking and cleaning arrangement…etc.(iii) 1000 litre capacity a) Sintex |
| 229 | 25.12:- Providing precast RCC slab over drain, septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire…. Etc.(a) 100mm thick slab. |
| 230 | 5.3.5:- Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories…etc.(II) P.V.C.(v) 110mm diametre |
| 231 | 5.3.5:- Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories…etc.(II) P.V.C.(ii) 63mm diametre |
| 232 | 5.3.4:- Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary….etc.iii) Bore hoe of 125mm diametre |
| 233 | 3.2.1:- Supplying, fitting and fixing C.P. bib cock 15mm dia of approved brand as directed and specified (G.I. & C.P. pipes will be measured separately)(I) Essco make (Delux/Sumthing spl./Propical)(b) Long body bib cock with wall flange |
| 234 | 3.3.1:- Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separatelyl)I) Brass stop cock (heavy) of sant make(iv) 32mm dia |
| 235 | 3.4.1:- Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows (Pipes will be measured and paid separately)a) C.P.C.H.b) Heavy type |
| 236 | 39.1.1:- (Elect. SOR) 1 HP Siingle Phase Jet Set (Horizontal/Crompton Greaves/Aquatic/CRI/V-Guard/Calma make) 2900 rpm with DOL Starter…etc. |
| 237 | 11) Civil Works (Septic Tank):-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 238 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 239 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 240 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b)Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.(a) 12mm dia |
| 241 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) c)ISI approved mild steel reinforcement bar (M.S. bar) |
| 242 | 3.2.1.:- Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:3.2.1.1:- Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face |
| 243 | 2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticisera) M15 grade concrete or Prop. 1:2:4 |
| 244 | 4.1.4:- Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.(I) In Sub-structure upto plinth level including dewatering if necessaryb) In prop. 1:4 |
| 245 | 4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately)(A) 112mm thick brick wall(c) In proportion 1:5. (1 cement:5 sand) |
| 246 | Filling sunken floor with broken jhama brick bats and sand including compacting and supplying…. |
| 247 | 6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough sideb) In cement mortar 1:4 |
| 248 | 5.1.2:- 25mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12… |
| 249 | 1.48:- Providing fitting and fixing 450mm dia 90mm thick C.I. Man hole cover and frame of 25 Kg. |
| 250 | 12) Internal & External Electrification:-2.1:- Wiring for light/ fan/ call bell point with 2x1.5 sq.mm PVC. insulated single core unsheathedindustrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible brightannealed electrolytic copper conductor for voltagegrade up to 1100 volts (Finolex /RR Kabel /Niccoor Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS:9537 Part-III Conduit (Berlia/AKG/Precision/ Presto Plast/ Polycab/MW or equivalent make as approved by the Deptt.) including 6 AMP FLUSH TYPE SWITCH/ BELL PUSH (Anchor/ Penta/ Gold Medal/ Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) with phenolic laminated sheet cover ceiling rose (Anchor/Penta/Gold medal/ Kolorkany.Kom/ Havells or equivalent make as approved by the Deptt.) etc.2.1.1:- Short point up to 3 metre length |
| 251 | 2.1.2:- Medium point up to 6.00 metre length |
| 252 | 2.1.3:- Long point up to 10.00 metre length |
| 253 | 2.2:- Wiring to 5 a pin 6 Amps plug point with 1.5 sq.mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage upto 1100 volts (Finolex/RR Kabel or equivalent make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS:9537 PART-III rigid PVC conduit (Berlin/AKG/Precision/ Presto Plast/ Polycab/ MW or equivalent make as approved by the deptt.)2.2.2:- Medium point upto 6.00 metre length |
| 254 | 2.3:- Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system including earth continuity with 2.5 sq. mm cableto the 3rd pin of the socketas required complete with20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)2.3.2:- Medium point up to 6.00 metre length |
| 255 | 2.7:- Wiring for drawing sub-main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/ RR kabel or equivalent make as approved by the Deptt.) PVC conduit.2.7.1:- with 2 x 2.5 sq.mm + earth continuity with 1x1.5 sq.mm in 20 mm dia 2mm thick/heavy rigid PVC IS:9537 Part-III conduit. |
| 256 | 2.7.2:- with 2 x 4 sq.mm + earth continuity with 1x2.5 sq.mm in 20 mm dia 2mm thick/heavy rigid PVC IS:9537 Part-III conduit. |
| 257 | 2.7.3:- with 2 x 6 sq.mm + earth continuity with 1x4 sq.mm in 25 mm dia 2mm thick/heavy rigid PVC IS:9537 Part-III conduit. |
| 258 | 2.9:- Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVC20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.2.9.4:- With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit. |
| 259 | 2.10:- Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan. |
| 260 | 11.12:- Supplying and fixing of polished brass bracket of 18 S.W.G., 25 cm long cast back plate and brass |
| 261 | 11.26:- Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/ angle holder/ decorative bracked/ bulk head fitting/ pendent holder etc. as specified and directed by the Deptt. |
| 262 | 11.32:- Supplying and fixing of Call bell ( Buzzer )including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required. |
| 263 | 14.1:- Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt.14.1.1:- 20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) |
| 264 | 15.2:- Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 (ABB, Schneider MG, Legrand, Hager, Crabtree xpro make)15.2.1.2: 6 Way SPN double door |
| 265 | 15.2.1.3:- 8 Way SPN Double Door |
| 266 | 15.8:- Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1: ABB, Schneider MG, legrand, Hagermake)15.8.1.1:4 way TPN (4+12)double door |
| 267 | 16.1:- Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.16.1.1:- B series(Schneider mg, Legrand, Hager, Crabtree Xpro make)16.1.1.1:- 6 to 32 A |
| 268 | 16.3:- Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.16.3.1 B Series(Schneider mg, Legrand, Hager, Crabtree Xpro make)16.3.1.21:- 40A |
| 269 | 16.3.1.3:- 63A |
| 270 | 16.6:- Supplying with fitting and fixing 4P 10 KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the Deptt.16.6.2 C Series (ABB, Schneider MG, Legrand, Hager, Crabtree Xpro make)16.6.2.5:- 100A |
| 271 | 16.16:- Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt.16.16.1: 25 KA 415V 50 Hz 4P MCCB(Schneider, legrand, Siemensmake)16.16.1.1:- 16A |
| 272 | 16.16.1.3:- 40A |
| 273 | 16.16.1.4:- 63A |
| 274 | 16.16.1.7:- 125A |
| 275 | 18.19:- Supplying including installation, commissioning of vermin and dust proof totally enclosed phosphatised power painted cubical outdoor type floor/wall mounting compartmentalize panel board of size 1:35 M x 1.50 M x 0.40 M made of 16 SWG (1.66mm) thick C.R. sheet and 35mm x 35mm x 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 3:3:6 PCC foundation including brick soling/ grouting etc. complete neatly wiring done with provision for one no. 125/160A 4 pole MCCB or Switch Fuse Unit as incomer and provision for 8 nos. DP or TPN outgoing as specified and directed by the Deptt. confirming to IP 43 protection comprising of the following electrical items:1. 25mm x 5mm 4 strip copper Bus-Bar 1.4M length each2. Digital 3 phase Voltmeter Accuracy class 0.5 - 1 no.3. Digital 3 phase Ammeter Accuracy class 0.5 - 1 no.4. Pilot lamp with integral ckt LED 110-230V (Red, yellow & blue) - 3 nos.5. Voltmeter & Ammeter Selector Switch - 2 nos.6. 2 A Slide fuse unit - 3 nos.(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) |
| 276 | 22.7:- Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipewith necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mmhinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . |
| 277 | 22.10:- Supply, installation & testing of Copper Plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. G.I. medium duty watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . |
| 278 | 22.16:- Supplying & laying of 8 SWG Copper earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. |
| 279 | 23.2:- Supplying, installation, testing and commissioning of the following outdoor light of LED/MH/HPSV luminaries complete with all accessories such as ballast, capacitor, lamp ignitor and driver as required complete with necessary support/foundation with 2.5 sq.mm PVC insulated S.C. copper conductor as required and as directed by the department.23.2.6:- SWF 231, 1 X SON/MHNTD 150W Philips make integral floodlight luminaire with die cast aluminium housing & thoughened glass cover (IP-65) or equivalent (Equivalent will be delected by the department considering the mother items rate) Havells/WIPRO/BAJAJ/CROMPTON/HPL/SOLAR/JAQUAR Make. |
| 280 | 23.11:- Supplying including installation, connection as approved by the Deptt. with 2x2.5 sq.mm copper FR cable, testing and commissioning of following BOLLARD LIGHT on cement concrete foundation including lamp, driver, ballast as required complete as directed and specified by the deptt.23.11.1:- NCG 10 1 X A60-60W, 1SPLS 9W, Philips make or equivalent (Equivalent will be selected by the deptt. considering the mother items rate) (WIPRO/JAQUAR make). |
| 281 | 27.1:- Supplying including fitting fixing of followingA.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].27.1.3:- Premium model 1400 mm sweep. (ORIENT PSPO make)/ premium model 1400 mm sweep SS-390 Deco. (Havells make). |
| 282 | 27.6:- Supplying fitting and fixing of ceiling fan regulator including connection etc. complete as required.27.6.2:- Electronic Type |
| 283 | 32.1:- Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade solid aluminium conductor up to 10 sq.mm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core upto 70 sq.mm balance aluminium strip, Galvanised for cables up to 2 x 10 sq.mm 3x10 sq.mm, 4x6 sq.mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (part i) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering sand cushioning etc. complete handling of surplus soil, debris etc to porper place as specified and directed by the deptt. (Nico/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent).32.1.4:- 4 Core A2XWY A2XFY32.1.4.7:- 50.00 Sq.mm 4 Core armoured U.G. cable. |
| 284 | 32.2:- Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade solid aluminium conductor upto 10 sq.mm balance stranded conductor, XLPE insulated, Armour (Aluminium for single core up to 70 sq.mm balance aluminium strip, Galvanised for cables up to 2 x 10 sq.mm 3 x 10 sq.mm, 4 x 6 sq.mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 65/1100V grade as per IS 7908 (part 1) 1988 armoured U.G. cable laid in ground/ partially in air (as required for termination over ground including excavation of cable trench up to depth of 75 cm, refilling, protective brick covering sand cushioning etc. complete handling of surplus soil, debris etc. to proper place as specified and directed by the deptt. (Nico/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent).32.2.1:- 1 Core A2XWY32.2.1.18:- 4 X 70.00 sq.mm 1 core armoured U.G. cable |
| 285 | 35.1:- Supplying, installation testing and commissioning of the following rating copper wound indoor/ outdoor type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T./H.T. metering etc. (excluding the cost of load security) and making necessary arrangement for charing approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 stars, above 200KKVA as per CEA guidelines for losses along with LV enclosures.35.1.1:- 25KVA, 50Hz. 11/0.433 KV. Oil filled transformer with Off Circuit tap charge. |
| 286 | 36.3:- Supplying and erection PSC p;oe 9.75 metre long, the pole is to be erected in 1:3:6 plain cement concrete foundation of size 1.50m x 0.45 x 0.45m having PCC BASE FOUNDATION 15 CM X 60 CM X 60CM including edge brick soiling and plastering above G.L. portion (0.30 metre) complete with excavation of earth, handling of surplus soil, debris etc. to be proper place and refilling etc. as specified and as directed by the deptt. |
| 287 | 36.4:- Supplying and erection of L.T. stay set complete (Garvanized) with 19mm dia x 1.8m long stay rod anchor plate of size 30 cm x 30cm x 6.4 mm thimble stay clams turn buckle (19mm x 60cm) 7/4 SWG dia G.I. stay and strin insulation etc. in cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate) 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department. |
| 288 | 36.7:- Supplying and fitting fixing of galvanised channel of 75mm x 40mm x 65mm x 2200mm long complete and as directed by the department. |
| 289 | 36.9:- Supplying and fitting fixing of 11 KV Cross arm complete with clamps, bolts, nuts etc. as required and as directed by the department. |
| 290 | 36.14:- Supplying and erection of 11 KV pin insulator (poly) with G.I. pin, bolts and nuts coach screw etc. as required and as directed by the department. |
| 291 | 36.16:- Supplying and erection of 11 KV pin insulator (poly) 45 KN with hard ware fittings etc. as required and as directed by the department. |
| 292 | 36.22:- Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department. |
| 293 | 36.23:- Supplying and fixing of 11 KV 150 AD.O fuse set complete as required and as directed by the department. |
| 294 | 36.24:- Supplying and erection of 11 KV 5KA lighting arrestor (poly) set complete as required and as directed by the department. |
| 295 | 36.30:- Supplying and string up AAC Racoon conductor in the existing P.S.C./M.S./ Galvanized pole with binding etc. as required and as directed by the department. |
| 296 | 36.32:- Supplying including installation of 4\" dia C.I. earth pipe complete as required and as directed by the department. |
| 297 | 36.33:- Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department. |
| 298 | 39.6:- Supplying including installation, connection as approved by the deptt., testing and commissioning of SUBMERSIBLE PUMP SET, Single Phase with steel cable rope and submersible cable complete as directed and specified by the deptt.39.6.2:- Single phase submersible motor pump set (Texmo/Crompton Greaves/Aquatic/CRI/V-Guard/Calma make) suitable for 76mm bore well. 1 HP STAGE 10 to 32 with control panel. |
| 299 | ECBC 3.8:- Supplying, installation, testing and commissioning of the following indoor decorative recessed type mirror optics down lighter luminaries complete with all accessories such as ballast, starter, lamp etc. in the false ceiling type Armstrong/Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm P.V.C. insulated S.C. Copper conductor as required and as directed by the department.ECBC.3.8.26:- DDLHR 218/G/SL 2 x 18 W CFL CROMPTON make recessed mounted horizontal lamp low height (85mm) down light with matt finish reflector and centre frosted toughened glass for glare free illumination & integral control gear box including 2 x 18W CFL or equivalent (Equivalent will be selected by the deptt. considering the mother items rate (equivalent PHILIPS/WIPRO/BAJAJ/Havells/HPL/SOLAR/JAQUAR make). |
| 300 | ECBC 3.28:- Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ ceiling including connection with 1.5 sq.mm PVC insulated SC copper conductor as required and as directed by the department.ECBC.3.28.1:- LED Lamp indoor application, operating voltage 90V - 250V, 12V DC I. Model GN11J - 2 or equivalent, LED lamp with mains input (Mke Philips/Bajaj/Schneider/Havells) |
| 301 | 226/:- DTR Fencing (as per APDCL rate for the year - 2018) |
| 302 | Payment to be made to the APDCL Authority for load Security and Meter connection. |
| 303 | 13) Landscaping with Parking Sets:-20.2:- Supplying and laying of selectedgrass turves [ size 60 cm x 30 cm] after preparing the land by removing of all unwanted debrises ( rubbles, pebbles, plant roots etc.), mixing of organic manure,levelling the surface and initial maintenance by proper and periodic rolling, mowing and irrigation etc.( as specified) for a period of six months from the date of laying of grass including the application of recommended dose of fertilizers(N:P:K) mixture as specified and directed by the department.(b) BY CARPET GRASS (Axonopus affinis) : |
| 304 | 20.3:- Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)(C) With Mokara (III) Using concrete pot of 60 cm dia. |
| 305 | 20.4:- Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)(H)With Iron Cross Begonia (III) Using concrete pot of 60 cm dia. |
| 306 | 20.5:- Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)(D)With Fan Palm /Finger palm (III) Using concrete pot of 60 cm dia. |
| 307 | 20.9:- Supplying and planting of selected rose plants on the ground (as specimen bush) including the preparation of the pit ( 45 cm x 45 cm x 45 cm ), removing unwanted debrises, filling the pit with manure and fertilizers as per specification and necessary maintenance for a period of 1year from the date of planting complete as specified and directed . (B) With Hybrid tea rose/ Miniatune rose |
| 308 | 20.12:- Supplying and planting of ornamental trees (1\"-0\" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. SHADE TREE(G) Christmas tree / Kuki |
| 309 | 20.19:- Half brick circular tree guard internal diametre 1.25 m and height 1.2 m above ground and 0.02 m below ground bottom two coarses laid dry and top three coarses in cement mortar 1:6 and the intermediate coarses being in dry honey comb masonry as per design complete. |
| 310 | 14) RCC Drain in Auditorium Hall Campus:-1.1:- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil |
| 311 | 4.1.1:- Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete.(a).Brick on flat soling. |
| 312 | 2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
| 313 | 18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL(ii)Super Ductile (SD) TMT reinforcement bars |
| 314 | 32.1.1:- Providing and laying plain/reinforced cement croncrete works using cement, coarse sand & 20mm down graded stone aggregate with cost of necessary form work including dewatering if necessary, and curing for reinforced cement concrete work complete as directed (Reinforcement will be measured and paid separately) I) Using mixture machine(A)In sub - structure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticiser(c)M25 grade concrete |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy