Day To Day Maintenance Works At Trikuta Rehabilitation Complex Opp. Phe Office At B.C. Road Jammu For Year 2021-22 Upto March, 2022- 1 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer Incharge: 1:4:8 Or Leaner Mix ( I / C Equivalent Design Mix ) ( Incl. Carriages Complete Job ) 2 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. 3 Extra For Cutting Reinforcement Bars Manually / By Mechanical Means In Rcc Or R.B Work ( Payment Shall Be Made On The Cross Sectional Area Of Rcc Or R.B Work ) 4 Extra For Scrapping, Cleaning And Straightening Reinforcement From R.C.C. Or R.B. Work 5 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: In Cement Mortar 6 Removing Mortar From Bricks And Cleaning Bricks Incl. Stacking With A Lead Of 50 Mtrs ( Stacks Of Cleaned Bricks Shall Be Measured ) From Brick Work In Cement Mortar 7 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Meters Lead : 8 Of Area Of 3 Sqm. And Below 9 Of Area Beyond 3 Sqm 10 Taking Out Doors, Windows And Clerestory Window Shutters ( Steel Or Wood ) Including Stacking Within 50 Meters Lead : 11 Of Area Of 3 Sqm. And Below 12 Of Area Beyond 3 Sqm. 13 Demolishing Brick Tile Covering In Terracing Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 14 Demolishing Mud Phaska In Terracing And Disposal Of Material Within 50 Meters Lead 15 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead. 16 Repair To Plaster Of Thickness 12Mm To 20 Mm In Patches Of Area 2.5Sqm And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing Plastering The Wall Surface With White Cement Based Polymer Modified Self Curing Mortar, Including Disposal Of Rubbish, All Complete As Per The Direction Of Engineer-In-Charge. 17 Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Raking Out Old Putty : : 18 Float Glass Panes Of Thickness 4.0 Mm ( Weight Not Less Than 10Kg / Sqm ) 19 Float Glass Panes Of Thickness 5.0 Mm ( Weight Not Less Than 12.5 Kg / Sqm ) . 20 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 21 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) 22 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 23 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) 24 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 40 Mm Nominal Size ) 25 Brick Work With Common Burnt Clay ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Incl. Cost Of Bricks 26 Brick Work With Common Burnt Clay ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Excluding Cost Of Bricks 27 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level 28 Extra For Brick Work In Super Structure Above Floor V Level For Each Four Floors Or Part Thereof ( By Manual Means ) 29 Extra For Brick Work / Tile Brick / Aac Block Masonry In Superstructure Above Floor V Level For Each Four Floors Or Part Thereof By Mechanical Means: 30 Half Brick Masonry With Common Burnt Clay ( Non Modular ) Bricks Of Class Designation 7.5 In Foundations And Plinth Including Curing In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 31 Extra For Half Brick Masonry In Superstructure Above Plinth Level Upto Floor V Level. 32 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 33 Shelves ( Cast-In-Situ ) 34 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide 35 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 36 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 37 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Cold Twisted Bars 38 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. 39 Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded 40 Regrading Terracing Of Mud Phaska Covered With Tiles Or Bricks, In Cement By Dismantling Tiles Or Bricks, Removing Mud Plaster, Preparing The Surface Of Mud Phaska To Proper Slope, Relaying Mud Plaster Gobri Leaping And Tiles Or Bricks, Grouted In Cement Mortar 1:3 ( 1 Cement: 3 Fine Sand ) , Including Replacing Unserviceable Tiles Or Bricks With New Ones And Disposal Of Unserviceable Material To The Dumping Ground ( The Cost Of The New Tiles Or Brick Excluded ) Within 50 Meters Lead. 41 Raking Out Joints In Lime Or Cement Mortar And Preparing The Surface For Re-Pointing Or Re Plastering, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead. 42 White Washing With Lime To Give An Even Shade : 43 Old Work ( Two Or More Coats ) 44 Old Work ( One Or More Coats ) 45 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 46 Distempering With 1St Quality Acrylic / Oil Bound Washable Distemper ( Ready-Made ) Having Voc Content Less Than 50 Grams / Litre Of Approved Manufacturer And Of Required Shade And Colour Complete As Per Manufacturers’ Specifications, One Or More Coats On Old Work 47 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 48 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade, One Or More Coats On Old Work. 49 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade, One Or More Coats On Old Work. 50 15Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix: 51 1 : 4 ( 1 Cement : 4 Fine Sand ) 52 1 : 6 ( 1 Cement : 6 Fine Sand ) 53 12Mm Cement Plaster Of Mix: 54 1 : 4 ( 1 Cement : 4 Coarse Sand ) 55 1 : 6 ( 1 Cement : 6 Coarse Sand ) 56 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface. 57 Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) 58 Finishing Walls With Water Proofing Cement Paint Of Required Shade: Old Work ( One Or More Coats Applied @ 2.20 Kg / 10Sqm ) Over Priming Coat Of Primer Applied @ 0.80 Liters / 10Sqm Complete Including Cost Of Priming Coat. 59 Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 60 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade.Two Or More Coats On New Work 61 Painting On G.S Sheets With Synthetic Enamel Paint Of Approved Band And Manufacture Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. 62 Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 63 1 Mm Thick 64 2 Mm Thick 65 Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side, Up To Seven Storey Height Made With 40 Mm Dia M.S. Tube 1.5 M Centre To Centre Horizontal And Vertical Tubes Joining With Cup And Lock System With M.S. Tubes, M.S. Tube Challies, M.S. Clamps And M.S. Staircase System In The Scaffoldings For Working Platform Etc. And Maintaining It In A Serviceable Condition For The Required Duration As Approved And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connection With The Building Etc. Wherever Required For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc Complete As Per Directions And Approval Of Engineer-In-Charge. The Elevational Area Of The Scaffolding Shall Be Measured For Payment Purpose. The Payment Will Be Made Once Irrespective Of Duration Of Scaffolding. 66 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work ( Parkash, Suyra Make ) Or Equivalent 67 15 Mm Dia. Nominal Bore ( Medium ) 68 20 Mm Dia. Nominal Bore ( Medium ) 69 25 Mm Dia. Nominal Bore ( Medium ) 70 32 Mm Dia. Nominal Bore ( Medium ) 71 Providing And Fixing G.I. Pipes Complete With G.I. Fittings Excluding Trenching And Refilling Etc. ( External Work ) ( Parkash, Suyra Make ) Or Equivalent 72 15 Mm Dia. Nominal Bore ( Medium ) 73 20 Mm Dia. Nominal Bore ( Medium ) 74 25 Mm Dia. Nominal Bore ( Medium ) 75 32 Mm Dia. Nominal Bore ( Medium ) 76 40 Mm Dia. Nominal Bore ( Medium ) 77 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) ( Uniqu / Drp Make ) 78 15 Mm Nominal Bore 79 20 Mm Nominal Bore 80 25 Mm Nominal Bore 81 32 Mm Nominal Bore 82 40 Mm Nominal Bore 83 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint With Two Coats Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. 84 15 Mm Diameter Pipe. 85 20 Mm Diameter Pipe. 86 25 Mm Diameter Pipe. 87 32 Mm Diameter Pipe. 88 40 Mm Diameter Pipe. 89 Providing And Fixing Pvc Pipe Including / Jointing With Seal Ring ( Finolex / Supreme ) Of Pressure @ 5.5 Kg / Cm2 90 75Mm Dia Pipe 91 110Mm Dia Pipe 92 150Mm Dia Pipe 93 200Mm Dia Pipe 94 Providing And Fixing Pvc Pipe Including / Jointing With Seal Ring ( Finolex / Supreme ) Of Pressure @ 5.5 Kg / Cm2 95 75Mm Dia Plain Bend 96 75Mm Dia Door Bend 97 75Mm Dia Cowl 98 110Mm Dia Plain Bend 99 110Mm Dia Door Bend 100 110Mm Dia Door Tee 101 110Mm Dia Tee Junction 102 Reducer Tee 110 Mm Dia To 75Mm Dia 103 Cowl 110 Mm Dia 104 75Mm Dia Door Tee 105 150Mm Dia Plain Bend 106 150Mm Dia Door Bend 107 Providing And Fixing Pvc Floor Trap Of Finolex / Supreme Make 108 Providing & Fixing White Vitreous China Water Closet Squatting Pan ( Indian Type ) Along With “S” Or “P” Trap Including Dismantling Of Old Wc Seat And “S” Or “P” Trap At Site Complete With All Operations Including All Necessary Materials, Labour And Disposal Of Dismantled Material I / C Malba, All Complete As Per The Direction Of Engineer-In Charge. 109 Orissa Pattern W.C Pan Of Size 580X440 Mm 110 Providing And Fixing White Vitrous China Pedestal Type Water Closet ( Hindware / Cera / Parryware Make ) ( European Type W.C Pan ) With 100Mm Pvc P&S Trap Incl. Cutting And Making Good The Walls And Floors Wherever Required 111 Providing And Fixing Wash Basin With C.I. Brackets, 15Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : 112 White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Taps 113 White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillar Tap. 114 Providing And Fixing White Vitreous China Pedestal For Wash Basin Completely Recessed At The Back For The Reception Of Pipes And Fittings 115 Providing And Fixinground Wash Basin White Vitrous China 450 Mm Dia Complete ( Hindware / Cera / Parryware Make ) 116 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265mm Sizes Respectively. 117 Providing And Fixing P.V.C Low Level Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete: 10 Liter Capacity -White 118 Pvc Connection For Flushing Cistern, Wash Basin, Sinks Etc 119 450 Mm Long 120 600 Mm Long 121 Providing And Fixing Solid Plastic Seat With Lid For Pedestal Type W.C. Pan Complete: White Solid Plastic Seat With Lid 122 Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 ( 1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 6 Mm Nominal Size ) As Per Direction Of Engineer-In-Charge And Finished Smooth. White Agaria Marble Stone 18Mm 123 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per I.S. 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : 124 610X460mm Bowl Depth 200Mm 125 470X420mm Bowl Depth 178Mm 126 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C Waste Fittings Complete: 127 Semi Rigid Pipe 32 Mm Dia 128 Flexible Pipe 32 Mm Dia 129 Providing And Fixing C.P Fittings ( Jaquar / Essco / Marc / Cera Make ) 130 Pillar Cock 131 Short Nose Bib Cock 132 Long Nose Bib Cock 133 Angle Valve 134 Mixer For Wash Basin 135 Mixer For Bathing ( Wall Mixer ) 136 Swan Neck Left / Right Tap 137 Providing And Fixing Sanitary Fittings Complete 138 C.P Jet With Rod Complete 139 C.P Gratings 4 140 C.P Gratings 6 141 C.P Extension Nipple 1 142 C.P Extension Nipple 2 143 Soap Dish 144 C.P. Towel Rod 2-0 ( 20Mm Dia ) 145 C.P. Towel Rod 1-6 ( 20Mm Dia ) 146 Towel Ring 200 Mm Dia 147 Waste Coupling For Wash Basin 32 Mm Dia 148 Waste Coupling For Laboratory Sink 50 Mm Dia 149 Shower With Arm 150 Conceled Stop Cock With Head 151 Glass Shelves Of Superior Quality 440 Mm Long 124 Mm Width 152 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 153 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top Slab With 1:1.5:3 Mix ( 1 Cement : 1.5 Coarse Sand ( Zone- Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand ( Zone- Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3Coarse Sand ) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 154 Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 155 Extra For Depth For Manholes Size 90X80 Cm With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 156 Demolishing W.C Platform Cement Concrete And Disposal Of Unservicable Material Upto Dumping Site At Ground Floor Road Side ( Maximum 3-0X4-0X1-6 ) 157 Providing And Fixing Aluminum Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixed With Dash Fastener Of Required Dia. And Size Including Necessary Filling Up Of Gaps At Junctions I.E, At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Felt Etc. Aluminum Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminum Snap Beading For Glazing / Panelling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge ( Glazing, Panelling And Dash Fasteners To Be Paid For Separately. ) 158 For Fixed Portion. Anodized Aluminum ( Anodized Transparent Or Dyed To Requiredshade According To Is:1868, Minimum Anodic Coating Of Grade Ac 15 ) 159 Powder Coated Aluminum ( Minimum Thickness Of Powder Coated 50 Microns ) 160 Providing And Fixing Aluminum Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixed With Dash Fastener Of Required Dia. And Size Including Necessary Filling Up Of Gaps At Junctions I.E, At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Felt Etc. Aluminum Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminum Snap Beading For Glazing / Panelling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge ( Glazing, Panelling And Dash Fasteners To Be Paid For Separately. ) 161 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately. ) Anodized Aluminum ( Anodized Transparent Or Dyed To Required Shade According To Is:1868, Minimum Anodic Coating Of Grade Ac 15 ) 162 Powder Coated Aluminum ( Minimum Thickness Of Powder Coated 50 Microns ) 163 Providing And Fixing 12Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board ( Conforming To Is: 12823 Grade-I Type-Ii ) In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-Incharge. 164 Pre-Laminated Particle Board With Decorative Lamination On Both Sides. 165 Repair To Aluminium Door Shutters Incl. Refixing / Fixtures / Acp Sheets Rubber Gasket / Aluminium Beeding Etc Complete ( Cost Of Acp Sheet Paid Separtely ) 166 Providing And Fixing Glazing In Aluminum Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In- Charge. ( Cost Of Aluminum Snap Beading Shall Be Paid In Basic Item. ) With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 167 Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg For Doors Including Cost Of Cutting Floors, Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-In- Plate Etc. Complete As Per The Direction Of Engineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness 168 Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6Levers Without Pair Of Handles ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete. 169 Providing And Fixing Aluminum Sliding Door Bolts Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc. Complete : 170 300X16mm 171 250X16mm 172 Providing And Fixing Aluminum Tower Bolts Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 173 200X10mm 174 1500X10mm 175 100X10mm 176 Providing And Fixing Aluminum Handles Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868 ) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc. Complete. 177 125Mm 178 100Mm 179 75Mm 180 Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6mm, With 40Mm Dia, Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer 181 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. ( Note: -Butt Hinges And Necessary Screws Shall Be Paid Separately ) . 182 Second Class Teak Wood ( 30Mm Thick ) 183 Second Class Teak Wood ( 35Mm Thick ) 184 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) . Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. 185 Particle Board 12Mm Thick. Plain Particle Board Flat Pressed, 3 Layer Or Graded Wood Particle Board Medium Density Grade I, Is : 3087 Marked 186 Providing And Fixing Wire Gauze Shutters Using Galvanized M.S. Wire Gauze Of Average Width For Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.63 Mm For Doors, Windows And Clerestory Windows With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws As Per Direction Of Engineer-In-Charge : Second Class Deodar Wood 187 Providing And Fixing Wooden Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surface Etc. Complete: 188 2Nd Class Teak Wood 50 X 12 Mm 189 50 X 20 Mm 190 Providing And Fixing Tiled False Ceiling Of Specified Materials Of Size 595X595mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Gms / Sqm Both Side Inclusive ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200 Mm Center To Center And Cross “T” Of Size 24X25 Mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200 X 600Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25 Mm Made Of 0.30Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 24X24x0.30Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27X37x25x1.6Mm Fixed To Ceiling With 12.5Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85X30x0.8 Mm Spaced At 1200Mm Center To Center Along Size 85X30x0.8 Mm Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. ( The Rate Is Excluding The Cost Of Tiles Which Will Be Paid For Separately ) . 191 Gi Metal Ceiling Lay In Perforated Tegular Edge Global White Colour Tiles Of Size 595X595 Mm And 0.5 Mm Thick With 8 Mm Drop; Made Of Gi Sheet Having Galvanizing Of100 Gms / Sqm ( Both Sides Inclusive ) And 20% Perforation Area With 1.8 Mm Dia Holes And Having Nrc ( Noise Reduction Coefficient ) Of 0.5, Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending And Perforation, And Backed With A Black Glass Fiber Acoustical Fleece. 192 Providing Of Water Proofing Treatment To The Roof Slab, W.C And Bathrooms By Austrian Technology Using Diamond Shield And Fiber Mesh Covered With Two Or More Coats Of Specified Chemical Or Using Fosroc, Sika Of Basf Water Proofing Chemical. A Primer Coat Of Specified Chemical To Be Applied Before Fixing / Laying Of Fiber Mesh Complete 193 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : ( A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With With Water Proofing Cement Compound @ 0.253Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. ( B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm . This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 194 Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : ( A ) After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound@ 0.253 Kg / Sqm. ( B ) Laying Second Layer Of Fibre Glass Cloth When The First Layer Is Still Green. Overlaps Of Joints Of Fibre Cloth Should Not Be Less Than 10 Cm. ( C ) Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.670 Kg. / Sqm. And Coarse Sand @1.289 Kg / Sqm. This Will Be Allowed To Air Cure For 4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30Cm On Parapet Wall And Tucked Into Groove In Parapet All Around. ( D ) Fourth And Final Layer Of Brick Tiling With Cement Mortar ( Which Will Be Paid For Separately ) For The Purpose Of Measurement The Entire Treated Surface Will Be Measured. 195 Cement Concrete Flooring 1:2:4 ( 1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry And Curing Complete, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 196 40Mm Thick With 20 Mm Nominal Size Stone Aggregate 197 50 Mm Thick With 20Mm Nominal Size Stone Aggregate 198 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours And Shades, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Including Grouting The Joint With White Cement And Matching Pigments Etc. Complete. 199 Size Of Tile 600X600 Mm 200 Size Of Tile 800X800 Mm 201 Providing And Fixing Anti-Skid Premium Tiles On Floor ( Thickness To Be Specified By The Manufacturers ) Of Ist Quality Of Rak, Kajaria Make In Any Colour Laid On 20Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Incl. Pointing The Joints With White Cement And Matching Pigment Etc Complete 202 300X300mm 203 600X600mm 204 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete 205 Size Of Tile 600X600 Mm 206 Kota Stone Slab 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement:3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing, Polishing And Curing Complete 207 Disposal Of Unserviceable Dismentled Material / Waste Mulba By Mechanical Transportation Outside Municipal Limits Incl. Cost Of Loading, Unloading, Stacking Complete. ( 10Kms Lead ) 208 Grinding And Polishing Old Terrazo Flooring / Skirting With Floor Polish Of Specified Brand For Smooth Finishing Incl. Disposal Of Waste Material Of Griding / Polishing From Site Of Work To Dumping Site At Ground Floor 209 Providing And Fixing Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels 210 Granite Of Any Colour Or Shade ( Area Of Slab Over 0.5 Sqm ) 16Mm Thick 211 18Mm Thick 212 Providing Edge Moulding To 18 Mm / 16 Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. ( Grantine Work ) 213 Extra For Providing Frosted Glass Panes 4 Mm Thick Instead Of Ordinary Float Glass Panes 4 Mm Thick In Doors, Windows And Clerestory Window Shutters. ( Area Of Opening For Glass Panes Excluding Portion Inside Rebate Shall Be Measured ) 214 Providing And Fixing M.S Wire Guage To Old Wood Shutters / Steel Shutters Incl. Removing And Fitting Of Shutters Complete 215 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc Including Priming Coat With Approved Steel Primer All Complete. 216 Fixed To Steel Windows By Welding 217 Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc 218 Providing And Fixing Pvc Panelling In Walls 8 To 10 Mm Thick Incl. All Fittings And Fixtures Complete ( Wall Affair Or Any Equivalent Make ) 219 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete 220 15Mm Nominal Bore 221 20Mm Nominal Bore 222 Providing 1 ¼ “ Wooden Moulded Beading To The Ceiling Incl. Cost Of Nails, Wastage Etc Complete 223 Providing And Fixing 1 Wooden Gola To The Ceiling Incl. Cost Of Nails, Wastage Etc Complete 224 Providing Fency Knoob To The Cupboard Shutters Complete Job 225 Providing And Fixing 19Mm Thick Wooden Board Shutters To Cabnit Incl. M.S Hinges And Screws Complete 226 Providing And Fixing Hand Held Jet Sprayer ( Hindware ) Complete 227 Providing And Fixing Pvc Bend 40Mm Dia ( Superior ) 228 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length ( Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Separately ) : Sal Wood 229 Dismantling Aluminum / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material Within 50 Meters Lead As Directed By Engineer-In-Charge. 230 Providing And Fixing Anodized Aluminum Grill ( Anodized Transparent Or Dyed To Required Shade According To Is: 1868 Minimum Anodic Coating Of Grade Ac 15 ) Of Approved Design / Pattern, With Approved Standard Section And Fixed To The Existing Windows Frame With C.P. Brass / Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodized Aluminum Standard Section Around The Opening, All Complete As Epr Requirement And Direction Of Engineer-In-Charge. ( Only Weight Of Grill To Be Measured For Payment ) 231 Aluminium Sheet For Doors 1Mm Thick 232 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 233 Hot Finished Welded Type Tubes 234 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot And Cold Water Supply, Including All Cpvc Plain And Brass Threaded Fittings. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Internal Work Concealed Fixing The Pipe With Clamps At 1.00 Meter Spacing Including Cutting Chases And Making Good The Wall Etc. 235 15Mm Nominal Outer Dia Pipes 236 20Mm Nominal Outer Dia Pipes 237 25Mm Nominal Outer Dia Pipes 238 Providing And Fixing 6 Mm Water Proof Ply Complete Job 239 Providing And Fixing 12 Mm Water Proof Ply Complete Job 240 Providing And Fixing 19 Mm Water Proof Ply Complete Job 241 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) 242 25 Mm Nominal Bore 243 32 Mm Nominal Bore 244 40 Mm Nominal Bore 245 50 Mm Nominal Bore 246 Providing Corrugated G. S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Upto Any Pitch In Horizontal / Vertical Or Curved Surface ) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required 247 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gram / M2 248 Extra For Straight Cutting In C.G.S. Sheet Roofing For Making Opening Of Area Exceeding 40Sq.Decimetre For Chimney Stacks, Sky Light Etc 249 0.80 Mm / 0.63 Mm / 0.50 Mm Thick 250 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters 251 With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws ( 35Mm Thick ) 252 Supply And Installation Of Armstrong Medintech Plus Pur Homogenous Vinyl Sheet Flooring , Inc, 2 Metre Wide And Overall Thickness Of 2Mm. The Thickness Of Wear Layer Would Be 2Mm. The Product Should Be Homogeneous And Single Layered. The Wear Surface Shall Consist Of Impregnated Polyurethane Homogeneous Mixture Of Pvc With Trueshiled Technology, Plasticizers Without Dop, Urethane, Colour Pigments And Filler Calendered To From A Sheet, Colour And Pattern Details Shall Be Dispersed Throughout The Thickness Of The Wear Layer, Medintech Plus Shall Conform To Group I Wear Resistance As Per En 649. Clean Room Certified With Class A As Per Astmf5100. Flammability Resistance Of Class Ba-Sl As Per Gb8624-2006, Dynamic Coeffcient Of Friction Of Class Ds As Per En 13893, Thermal Resistance Of 0.072M2k / W As Per En 12667, Thermal Conductivity Of 0.071W / Mk As Per En12524, Impact Sound Reduction Of 3Db As Per Iso 10140. Slip Resistance Of Class R9 As Pedin 51130. Residual Indentation Of 0.03Mm As Per Gb / T 4085-2005. Color Fastness Rating Of 6 As Per Iso 105-B02, Total Weight Being 2.8Kg / M2 As Per En430. The Product Shall Be Suitable For Applications In Class 23 / 34 / 43 Areas As Per En685. Product Shall Exhibit Antistatic Behaviour, Resistance To Bacteria, Resistance To Chemical, Resistance To Staining Suitablity To Castor Chair. The Product Shall Be Floor Score Certified With No Svhc Content Published By European Chemicals Agency ( Reach ) , Product Shall Contribute To Leed Points Under Indoor Environment Quality ( Leed Eq ) And Material And Resource ( Leed Mr ) Category 253 Providing And Fixing Vertical Blinds For Windows Including All Fixtures And Fittings, Screws, Brackets Etccomplete Job 254 Providing And Fixing Of Brass Phase For Taps / Pillar Cocks ( Heavy Duty ) 255 Providing And Fixing Of Disk Type Brass Phase For Taps / Pillar Cocks ( Heavy Duty ) 256 Providing And Fixing Of Door Mats Of Standard Make 257 ( 3-0X1-6 ) 258 ( 2-0X1-6 ) 259 Providing And Fixing Cupboards Incl. Frame Of 2Nd Class Deodar Wood 19Mm Thick Partical Board With Decorative Shutters Incl. Internal Box Of 19Mm Partical Board Complete With Paiting With All Fittings And Fixtures 260 Providing And Fixing Wallpaper Of Required Colour, Shade And Design Of Standard Make As Directed By The Engineer -In-Charge 261 Providing And Fixing Acrylic Wall To Wall Carpet ( Dotted ) Including Skirting 262 Providing And Fixing Acrylic Name Plate ( Writing On Both Sides ) 263 Supply Of Labour ( Mazdoor ) For Various Day To Day Works As Per Directions Of Engineer In Charge 264 Supply Of Carpanter For Various Day To Day Works As Per Directions Of Engineer In Charge 265 Supply Of Plumber For Various Day To Day Works As Per Directions Of Engineer In Charge 266 Supply Of Sweeper For Various Day To Day Works As Per Directions Of Engineer In Charge 267 Cleaning Of Pvc Overhead Water Tanks By Engagingmachines As Per Directions Of Engineer In Charge 268 Providing & Fixing Of Curtain Including Curtain Roads Complete Job 269 Providing & Fixing Of Multi Locks To Cup-Boards ( Godrej ) 270 Providing & Fixing Of Door Closer. 271 Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Confirming To Is:4454 Part-1 And M.S. Top Cover Of Required Thickness For Rolling Shutters. 80X1.25 Mm M.S. Laths With 1.25 Mm Thick Top Cover 272 Providing And Fixing Ball Bearing For Rolling Shutters. 273 Providing And Fixing Of Pvc Sheet ( 2Mm Thick ) 274 Providing And Fixing Of 19Mm Thick Pre-Laminated Board In Paneling Over Wooden Frame Including Removing Of Old Damaged Paneling And Anti-Termiting The Same ( Complete Job ) 275 Providing And Fixing Painting Wire Gauge Shutters, Comprising As Per Window Frame Of Built Up Ms Sections 12Mm X 50Mm Rectangular Tube With Wire Guage Shutter Made Of Z-Section Including Hinges, Riveted With Frame Of 20Mm X 3Mm Flat Iron Complete Job ( Sample Window Available At High Court Building ) Including Priming And Painting As Per Directions Of Engineer In Charge. 276 Providing And Fixing Of Wooden Flooring Of Specified Shade And Brand As Per Directions Of Engineer In Charge Including Base Coat Of Foam Complete Job. 277 Providing And Fixing Wooden Profile Grade A To Wooden Flooring Of Specified Brand As Per Direction Of Enigneer In Charge 278 Providing And Fixing Aluminium Work ( Powder Coated ) For Doors, Windows Ventilators And Partitions With Extruded Built Up Standars Tubular Sections / Appropriate Z. Sections, Including Glazed Paneling / Pvc Panelingand Other Sections 3.25X1.5Mm Thick Of Approved Make Conforming To Is : 733 And Is : 1285, Fixed With Dash Fastener Of Required Dia. And Size Including Necessary Filling Up Of Gaps At Junctions I:E At Top, Bottom And Sides Witth Required Epdm Rubber / Neuropren Gasket Fell Etc Aluminium Sections Shallbe Smooth Rustfree Straight Mitred Jointed Mechanically Whereever Requred Including Snap Beading For Glazing Paneling C.P Brass Stainless Steel Screws Including Door Closers Stopper And All Accessories Required As Per Archetectural Drawing And Directioin Of Engineer-In-Charge. 279 Grinding And Polishing Old Kota Stone / Chips Flooring Surface With Floor Polish Of Specified Brand. 280 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade: 281 Old Work ( Two Or More Coats Applied @ 1.67 Liters / 10Sqm On Existing Cement Paint Surface ) 282 Old Work ( One Or More Coats Applied @ 0.90 Liters / 10Sqm ) 283 Providing / Fixing Polycorbonate Sheet Including Wastage Of 02Mm Thick ( 50 Micron ) Complete Job 284 Providing / Fixing Polycorbonate Sheet Including Wastage Of 10Mm Thick ( 50 Micron ) Complete Job 285 Providing And Fixing Brass Name Plate Written On Both Side Of HonBle Justices. ( Complete ) 286 Proving / Fixing Of Pre-Laminated Board Partition Fixed On Both Sides, Fixed Over Wooden Frame Of Ist Class Kail Wood Complete Job Including Painting Of Cupboards Etc. 287 Providing And Laying 80Mm Thick Factory Made Antiskid, Anti Glazed Pcc Interlocking Paver Blocks Of M-40 Design Mix As Per Is: 15658: 2006 ( Avg. Compressive Strength Of 8 Paver Blocks Shall Be Minimum 47.2 N / Mm2 Minimum Thickness Of Wearing Layer Is 6Mm, Max Abrasion Resistance 2Mm, Maximum Water Absorption Of 3 Units Is 6% By Mass ) Made By High Quality Paver Blocks Making Machine With High Level Of Compaction And Vibration And Of Approved Size And Shape Laid In Required Colour And Pattern ( Pigment Used Shall Not Be More Than 10% Of Weight Of Cement Used In Wearing Course Layer ) And Including 50Mm ( +5Mm ) Thick Compacted Bed Of Naturally Occuring, Clean, Well Graded, Sharp Coarse Sand ( Passing 4.75Mm Sieve ) Of Uniform Moisture Content 4% To 8% At The Time Of Spreading. Paver Units Should Be Placed With The Help Of Spacer ( 2Mm, 3Mm Wide ) Of Uncompacted Sand Cutting Machine, Filling The Spaces Between 25Mm And 50Mm Wide Concrete Having Minimum 1:1:2 Cement : Sand : 20Mm Crushed Stone Aggregate Mix. After Laying Paver Blocks They Shall Be Compacted With High Frequency, Low Amplitude Mechanical Flat Plate Vibrator Having Plate Area Sufficient To Cover A Minimum Of 12 Paving Units, After Compaction Joint Filling By Sand Shall Be Spread Over The Pavement ( Joint Filling Sand Shall Pass A 2.36 Mm No. 8 Sleve ) An Complete As Per Direction Of Engineer-In-Charge 288 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In-Charge, In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete ( 12X18 ) 289 Carriage Of Material By Mechanical Transport Incl. Loading / Unloading, Stacking At Site Of Work:- 290 Stone Aggregate Above 40Mm Nominal Size ( Average Lead 15.00Kms ) 291 Stone Aggregate Below 40Mm Nominal Size ( Average Lead 15.00Kms ) 292 Sand ( Average Lead 15.00Kms ) 293 Bricks ( Average Lead 15.00Kms )