construction of school Dhigarla Name of Work: CIVIL WORK AT GSSS, DHIGARLA BLOCK - RAJGARH 1.01 PART A CIVIL WORK 1.02 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 1.03 P.C.C. IN FOUNDATION Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 gradeed stone aggregate 40 mm nominal size). 1.04 Brick Work masonary with F.P.S bricks of Ist Class Desgnation in Foundation and plinth in. Cement Sand Mortar 1:6 ( 1 Cement :6 Coarse sand) 1.05 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand Light shade using shade cement.) 1.06 DPC:-Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required excluding the cost of centering, shuttering and reinforcement . M20 Grade Nominal Mix/Design mix. 1.07 Supply & Stacking good earth at site complete including loading unloading & transporation etc. 1.08 Brick Work masonary with F.P.S bricks of Ist Class Desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in Cement mortar 1:6 ( 1 Cement :6 Coarse sand) 1.09 Pillar Masonary :- Brick Work masonary with F.P.S bricks of Ist Class Desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in Cement mortar 1:4 ( 1 Cement :4 Coarse sand) 1.10 Stone Kharanja: RR Dry stone kharanja under floor 1.11 Lintel Beams:-Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 1.12 Slab & Beam:-Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 1.13 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. 1.14 Steel Reinforcement:-P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor five leve TMT bars (Conforming of relevent IS Code). 1.15 Door Frames:- Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. angle iron (40x40x5mm. @ 3 kg/m) 1.16 Doors:-Providing and fixing M.S. sheet 1 mm thick double leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint. Add extra for double leaf shutters 1.17 Glazed Window:Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Partly fixed and partly openable [ fixed area not to exceed 33%] 1.18 Wire Gauge Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at not exceeding 150 mm distance. 1.19 Guard Bars: P&F square bars or other flat welded to window/ventilators etc. 1.20 Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 1.21 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete(For area of each slab upto 2001 Sqcm) 1.22 Internal Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick 1.23 External Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick 1.24 Plaster(Ceiling): 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement: 3 fine sand) 1.25 Black Board : Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish: 12 mm thick 1.26 Grading roof for water proofing treatment with water proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) 1.27 Gola:- Providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. 1.28 White washing three or more coats to give an even shade on new surfaces . 1.29 Inernal Finishing: Distempering with dry distemper of approved brand shade ( two or more coats ) of required shade new work , over and including priming coat of whiting to give an even shade including all scaffolding. 1.30 Exterior Finishing: Finishing wall with water proofing cement paint of appd brand & manufacture and of reqd. shade to give an even shade including all scafolding New work (three or more coats applied at the rate of 3.84 kg/10 sqm) 1.31 Painting On Doors, Windows & Ramp Raling :- Painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shade new steel work (2 or more coat on new work). 1.32 Copping: Cement concrete flooring 1:2:4 (1 cement: 2 Course sand: 4 Greded stone aggregate) finishing with a floating coat of neat cement including cement slurry, making of lines or groove etc. complete but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm thick nominal size aggregate. 1.33 For rain water-P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 1.34 For rain water-P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia 1.35 Pipe Clip 110 mm dia 1.36 Supply & fixing of stainless steel pipe railing for ramp railing height, 90 cm. with 40 mm dia stainless steel pipe with 18 gauge with drop ( vertical post) at 90 cm C/C and intermidiate horizontal pipe with suitable height of same size and gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of engineer incharge. 2.00 PART B ELECTRICAL WORK 2.01 Wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make group-2 2.02 Light point 2.03 Short point (up to 3 mtr.) 2.04 Medium point (up to 6 mtr) 2.05 Long point (up to 10 mtr) 2.06 Fan point 2.07 Short point (up to 3 mtr.) 2.08 Medium point (up to 6 mtr) 2.09 Long point (up to 10 mtr) 2.10 Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make in surface/reces group - On board 2.11 S & F follwing sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. Group-2 25 mm dia 2.12 Supplying and drawi;ng FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. Group-2 2.13 1 x 1.5 sq. mm 2.14 2 x 1.5 sq. mm 2.15 2 x 2.5 sq. mm 2.16 P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. Group-2 6 A to 32 A rating 2.17 P & F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with 100 Amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB termination with copper lux, testing etc. as reqd. . group-2 Single door(Single Phase) 8 way 2.18 P & F strip fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating/stove enamelled non corrosive UV resist EP channel) complete with accessories(Low loss copperchoke, starter, starter seat)/Electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(Without tube)1x36 watts with OCCB. Group-2 2.19 P & F Fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts 2.20 P/I aying PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:1554 P-I of Groups of approved make in ground as per IS:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, Iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 2.21 P & F star rated double ball beari;ng capacitor start, aluminium body and blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 2.22 P & F IS:371 marked 6 amp sufface type celling rose inculuding making commection testing etc. grup-2 (E071400) 2.23 P & F ISI marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required 2.24 P & F 18 swg MS Recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hook with 100mm length extended on eeach side. gourp-1 2.25 P & F 18 SWG Sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmX 100 mmX60 mm 2.26 P & F paper phenolic resin bonded laminates confirming to IS: 2036- 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick 2.27 P & F socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required.