Required List Of Nabl Certified Instrument ( Non Lun ) For District And Sub Divisional Laboratories Of Phed In Dist.-Betul-2 Optic: Double Beam Optics With Aberration Corrected Holographic Diffraction Grating With 1200 Lines / Mm Blazed At 250Nm Con, BETUL-Madhya Pradesh

Government Departments has published Required List Of Nabl Certified Instrument ( Non Lun ) For District And Sub Divisional Laboratories Of Phed In Dist.-Betul-2 Optic: Double Beam Optics With Aberration Corrected Holographic Diffraction Grating With 1200 Lines / Mm Blazed At 250Nm Con. Submission Date for this Tender is 10-11-2021. Miscellaneous Finishes Tenders in BETUL Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29697670
Required List Of Nabl Certified Instrument ( Non Lun ) For District And Sub Divisional Laboratories Of Phed In Dist.-Betul-2 Optic: Double Beam Optics With Aberration Corrected Holographic Diffraction Grating With 1200 Lines / Mm Blazed At 250Nm Con
Open Tender
Indian
Madhya Pradesh
Betul
10-11-2021

Tender Details

Required List Of Nabl Certified Instrument ( Non Lun ) For District And Sub Divisional Laboratories Of Phed In Dist.-Betul-2 Optic: Double Beam Optics With Aberration Corrected Holographic Diffraction Grating With 1200 Lines / Mm Blazed At 250Nm Control: Micro Controller Based With Cube For Sample. Wavelength Range: 200-1100Nm Accuracy: ± 0.5Nm Repeatability: ± 0.2Nm Resolution: 0.1Nm Bandwidth: 2.0 Nm Photometric Range: ± 2.5Abs Accuracy : ±0.005 Abs At 1.0 Absrepeatability: ±0.002Abs At 1.0 Abs Instrument Calibration As Per Nabl Noms 3 Range 0.1 Μs To 200 Ms ( 6 Decadic Ranges ) , Accuracy ± 1% Of F.S ± 1 Digit, Resolution 0.001Μs, Ds Range 0.1 Ppm To 200 Ppt. ( 6 Decadic Ranges ) , Cell Constant Acceptable Form 0.1 To 5.0 , Width Auto / Manual Temp. Compensation . Instrument Calibration As Per Nabl Noms . 4 Range 0 To 14 Ph, Resolution 0.01 Stability 0.002 Ph Per Hourrelative Accuracy± 0.002 Ph ± 1 Digit Slope85% To 115% Calibration 2 / 3 / 5 Point Calibration Standards Buffers1.679, 7.000, 4.004 Or 9.183, 12.454 Buffer Deviation± 0.5 Ph Mv Range0 To ± 1999.9Mv Resolution0.1Mv Accuracy0.5 Mv ± 1 Digit Or ± 0.05% Of Reading Temperature Compensation Auto / Manual Range 0 To 99.9 Degree Celsius Resolution0.1 Degree Celsius Accuracy± 0.5 Degree Celsius ± 1 Digit Display2 Line, 20 - Character Alphanumeric Lcd Instrument Calibration As Per Nabl Noms 5 Range 0 To 1000 Ntu Repeatibility ± 1%Of Fsd Accuracy ± 1.5% ±1.5% Of Fsd In 0-500 & ±2%Of Fsd In 500-1000 Detector Photo Diode Source Led Display Lcd 2 Line, 16 Character, Alphanumeric Calibration Formazin Standard Solution Power230v, 50Hz + / - 10% Instrument Calibration As Per Nabl Noms 6 Sample Tube For Turbidity Meter Systronic Make, High Quality Fiber Make 7 Weighing Cap. 220 G , Readibility 0.0001Gm ( 0.1Mg ) Repeatibility 0.0001 Gm ( 0.1Mg ) Instrument Calibration As Per Nabl Noms 8 Vaccum Melted High Quality Non Magneticss, High Polished, Density 7.95G / Cm3 1Mg-200Gm , ( Set Includes 1, 2, 5, 10, 20, 50, 100.200 / Gm ) , With As Per Nabl Noms 9 Ac Adaptor- Universal 50-60 Hz, 100-240 Vac Power Adaptor, Lcd Graphic, Range ( Mv ) ±2000.0 10 Fluoride Ion High Combination Electrode For Ion Meter 11 Nitrate Ion High Combination Electrode For Ion Meter 12 Construction : Double Walled S.S. Body, Insulation :Glass Wool Insulation, Temp Range:5°C -65°C , Capacity :220 Liter , Accuracy: ±0.5°C, Led Display, Full Inner Glass Door, Well Polished Interior Body, Adjustable 3 Shelves, Heating System: Tubular S.S. Heater 13 With Temp. Controller, Max Temp. 700 Deg., M.S. Powder Coated, Top Body Made S.S. With Energy Regulator. 14 Filter Membrane Assembly Hand Operated Vaccum Pump ( For Bacteriological Test ) , High Quality Fiber Body. 15 Fully Automatic, Stainless Steel Interior, Digital Indicator , Temp. Controller , Upto 121°C-125°C Pedal For Lid Opening, 35 Liter Volume, 2 Kw Watt 16 Capacity 2Mlp, S.S. Top Plate & Body M.S. Powder Coated With Speed And Temp. Regulator, Max Temp. 120Deg. Big Size Max Rpm 1000 17 Hydrometer For Specific Gravity Measurement Range 1-2 Point Graduation Interval 0.1 Ml, With Nabl Calibration Certificate. 18 Humidity And Temperature Meter Display, Dual And Large For Humidity And Temp Type K Temperature For Humidity, Range 0-100%Rh, Resolution, 0.1%Rh Basic Accuracy 3.5%Rh For Temp. 200-1000°C Resulation 0.10 Deg. Upto 2000 Accuracy 3% With Accessories Carrying Case Manual K Temp. Rtd Probe With Cable Withindivisual Calibration Certificate From Nabl Accredited Lab. 19 1°C- 100°Ccalibration Certificate From Nabl Accredited Lab. 20 Refrigerator Capacity 320 Ltr / 300Ltr, Aesthtic Sleek Design, Digital Temperature Controller, Adjustable 4-6 Shelves With Lock System, Temperature Range:2’C To 8 Or 10’C, Cooling Type Frost Free, Uniform Cooling With Nabl Calibration Thermometer. 21 5 Star, Capacity 2.0 Ton 22 400°C, Triple Walled, M.S. Powder Coated, Digital Temperature Controller, Temp. Range 50°C To 400°C , Accuracy ±2°C, Size -18”*18”18 23 310 Ltr., Single Door, Incapacity 280Ltr. 24 With A Colour Including, Highly Glass Material, Size 240 Mm 25 Precision Thermometer Digital With Rtd Probe With Cable With Nabl Cetiifcate

Key Value

Document Fees
INR 2000 /-
EMD
INR 39850.0 /-
Tender Value
INR 19.92 Lakhs /-