| 1 | Supply & Clamping of 3 Core 95 Sq.mm 11KV grade armoured Aluminium conductor cable confirming to IS 7098 Pt. II with amndts.on the existing conveyor with suitable size existing clampsas directed by Engr. I/c complete with all materials labour tools and tackles. Brands: Universal / Gloster / RPG / Nicco / KEI / Havell’s /Polycab / Laser |
| 2 | Supply and laying of 3C X 95 Sq. mm HT 11 KV(E) grade XLPE insulated & PVC sheathed, armoured, PVC overall sheathed multi stranded aluminum conductor Cable of conforming to IS 7098 /Part-II approved brand including excavation of trench with Sand Cautioning andbrick protection on either side and top of the cable as directed by Engg. I/c with all materials ,labour tools and tackles.Brands: Universal / Gloster / RPG / Nicco / KEI / Havell’s /Polycab / Laser |
| 3 | Supply and providing of Heat shrinkable Outdoor End termination kit suitable to 3 Core 95 Sq.mm 11KV grade armoured Aluminium conductor cable as directed by Engr. I/c complete with all materials labour tools and tackles. Brand: Reychem/M-Seal/3 Mor any approved make. |
| 4 | Supply and providing of Heat shrinkable straight through jointkit suitable to 3 Core 95 Sq.mm 11KV grade armoured Aluminium conductor cable as directed by Engr. I/c complete with all materials labour tools and tackles. Brand: Reychem/M-Seal/3 Mor any approved make. |
| 5 | Supply, erection testing and commissioning of 200 Amps 11 KVpole mounted vertical operated single break single A B switchas directed by Engr. I/c complete with all materials labour tools and tackles.Brands: Any Approved |
| 6 | Supply, erection testing and commissioning of 11KV HG fuse set with copper rod arms as directed by Engr. I/c complete with all materials labour tools and tackles.Brands: Any Approved |
| 7 | Supply and fixing of 11 KV pin insulators with GI hard ware of approved brand as directed by engineer I/c with all materials, labour tools and tackles. |
| 8 | Supply and fixing of 11 KV Disc insulators with 33KV Alu. Grippers & GI hard ware of approved brand as directed by engineer I/c with all materials, labour tools and tackles. |
| 9 | Transportation, erection and placement of 11 to 13 meters long S.H.B.G rails /PCC / Spun Poles / mini mast duly welded with a existing base plate of size 300X300X10 mm in the existing trench for poles / struts with all material, labour and tools as directed by Engineer-in-charge.(S.H.BG Rail poles / mini mast supply by VPT at free of cost) |
| 10 | S I T & C of floor mounted Double door with canopyL T Outdoor panel for3 phase and neutral of size 1.3mtr. x 1.7 mtr x 0.6 mtr.(approx), made of 14 SWG sheet steel, with dust and varimin proof IP 55 protection with 2 coats ofapproved shade of enamel paint over one coat of red-oxide, thickness of 14 SWG comprising of following switch gear and metering devices of approved brands with suitable bus bar arrangement for 3 phase and neutral (400A rating for each phase and 200A for neutral) complete as directed by Engineer in charge including all labour tools and material. 1) Incomer: 4 pole 415 V, 50 KA, 250 A, MCCB withThermostatic setting,- 1 no.2) Out goings:a) 3 pole, 415 V, 35 KA 125A,MCCB -1Nob) 3 pole, 415 V, 35 KA 100AMCCB- 2 Nos. c) 4 pole 63 A MCB Isolator 4Nos. 3) a) Panel mountedDigital Voltmeter, Ammeter (each) 1No.b) LED pilot lamps 230V, 5 Nos SWITCH GEAR BRANDS : ABB/SIEMENS/ HAVELLS/ L&T / C&S/ GE/ |
| 11 | Supply, connecting testing and commissioning LT section Distribution box for double feeder ie., 3phase and neutral comprising 1 No- 300A incoming & 2 Nos out goings with knife switching type tin coated copper contracts for both male and female incoming & outgoing contacts duly fitted in polycarbonate box and necessary locking arrangement and fixing of the same on the wall / plinth with suitable hardware complete with all labour tools tackles and material as directed by Engineer-in-charge. |
| 12 | Supply laying / clamping /drawing of 3 ½core x 120Sq.mm armoured aluminum conductor cable cofg. IS 7098 Pt. I with latest amndt. including excavation of trench with Sand cushioning andbrick protection on either side and top of the cable / to the wall / through the existing pipe as directed by Engr. I/c complete with all materials labour tools and tackles.Brands: Glostar/Polycab/Havells/Nicco/Finecab |
| 13 | Supply laying / clamping /drawing of 3 ½core x 50Sq.mm aroured aluminuim conductor cable cofg. IS 7098 Pt. I with latest amndt. In the existing trench / to the wall / through the existing pipe as directed by Engr. I/c complete with all materials labour tools and tackles. Brands: Glostar/Polycab/Havells/Nicco/Finecab |
| 14 | Supply/Laying/clamping/drawing of 4 core, 6 SQ. MM, 1.1KV grade, XLPE insulated &PVC sheathed, armoured PVC overall sheathed multi standard aluminium conductor cable of approved brand and conforming to IS. 7098/1/188, in the existing trench /to the pole with existing clamps /in the pole/ pipe complete with all labour, tools and tackles . BRANDS:GLOSTER/FINECAB/HAVELLS/L&T |
| 15 | Supply, fixing, testing and commissioning of3 phase, neutral 400/415V, 4 Way,Double door MCB distribution board of approved brand on angular frame duly grouted to the wall or concealed type, including connecting the incomer supply and load connections as directed by Engineer in charge including all labour material tools and tackles. Incoming: 3 phase, 4poles, 400/440V, 63A, Isolator– 1 No. Outgoing: Single pole 6 to 32A MCBs – 12 Nos. BRANDS:HAVELLS/INDOASIAN/ANCHOR/L&T |
| 16 | Supply, fixing and commissioning of surface/concealed type point wiring with 2 runs of 1.5 Sq mm, PVC insulated, FRLS multi stranded copper conductor cable of approved brand with suitable colour coding in a suitable dia PVC conduit recessed on the wall/through false ceiling complete with junction boxes, bends, elbows etc., duly providing suitable 230v, 5/6A Modulartype control switch, bell push, batten holder/ceiling rose for light & fans etc. complete with all accessories for each point complete as directed by Engineer in charge including all labour ,material, tools& tackles.1)CABLEBRANDS:RADIANT/L&T/POLYCAB/PLAZA/FINOLEX/GLOSTER/RPG 2)PVC PIPE BRANDS:SUDHAKAR/ PLAZA MERCURY/RADIANT/AVON PLAST 3) FOR SWITCHES, SOCKETS, CEILING ROSES BRANDS:ANCHOR/CONA/MK/POINTER |
| 17 | Supply and running of wiring for ceiling fan/exhaust fan/socket points etc. with 3 runs X1.5Sq.mm PVC insulated, FRLS multi stranded copper conductor cable of approved brand with suitable colour coding in the existing PVC conduit complete withall labour ,material, tools& tackles.as directed by Engineer in charge including. Note: 1RMT equals to 3 runs of 1 mtr length of cable. CABLEBRANDS:RADIANT/L&T/ POLYCAB/ PLAZA/FINOLEX/GLOSTER/RPG/KEI |
| 18 | Supply and running of wiring for Switch boards / Power sockets with 3 runs X 2.5Sq.mm PVC insulated, FRLS multi stranded copper conductor cable of approved brand with suitable colour coding in the existing PVC conduit complete with all labour ,material, tools& tackles.as directed by Engineer in charge including. Note: 1RMT equals to 3 runs of 1 Mtr length of cable CABLEBRANDS:RADIANT/L&T/POLYCAB/ PLAZA/FINOLEX/GLOSTER/RPG/KEI |
| 19 | Supply and running of wiring forCircuit / Submains with 4 runs X 4 Sq.mm PVC insulated, FRLS multi stranded copper conductor cable of approved brand with suitable colour coding in the existing PVC conduit complete with all labour ,material, tools& tackles.as directed by Engineer in charge including. Note: 1RMT equals to 4 runs of 1 Mtr length ofcable CABLEBRANDS:RADIANT/L&T/POLYCAB/PLAZA/FINOLEX/GLOSTER/RPG/KEI |
| 20 | Supply and running of wiring for Circuit / Submains with 4 runs X 6 Sq.mm PVC insulated, FRLS multi stranded copper conductor cable of approved brand with suitable colour coding in the existing PVC conduit complete with all labour ,material, tools& tackles.as directed by Engineer in charge including.Note: 1RMT equals to 4 runs of 1 Mtr length ofcable. Make:RADIANT/L&T/POLYCAB/PLAZA/FINOLEX/GLOSTER/RPG/KEI |
| 21 | Supply and Fixing of 20 mm medium class PVC conduit / Casing capingalong with all accessories in surface/recess or through false ceiling in a approved manner complete with allmaterials, labour,tools & tackles as directed by engineer in charge. Make: SUDHAKAR / PLAZA / MERCURY / RADIANT / AVON PLAST/ MODI |
| 22 | Supply and Fixing of 25mm medium class PVC conduit along with all accessories in surface/recess or through false ceiling in a approved manner complete with allmaterials, labour,tools & tackles as directed by engineer in charge. Make: SUDHAKAR / PLAZA / MERCURY / RADIANT / AVON PLAST/ MODI |
| 23 | Supply and Fixing of GI box with modular plate and cover in front on surface or in recessed including providing and fixing of 3 pin 5/6A modular socket outlet and 5/6 Amps modular switch ,connections etc. as required with all materialslabour, tools & tackles as directed by engineer in charge. BRANDS: ANCHOR/ CONA / MK / POINTER / GOLD MEDAL OLIVE / MILLION ZOOM. |
| 24 | Supply and Fixing of GI box with modular plate and cover in front on surface or in recessed including providing and fixing of 6 pin 5/6A 15/16A modular socket outlet and 15/16 Amps modular switch ,connections etc. as required with all materialslabour, tools & tackles as directed by engineer in charge. BRANDS: ANCHOR/ CONA / MK / POINTER / GOLD MEDAL OLIVE / MILLION ZOOM. |
| 25 | Supply ,fixing & commissioning of 18-20 watt 1200mm length LED batten light with extruded aluminium housing and polycarbonate cover,to work on input voltage of 190-260VAC. Make: Wipro / Phillips / GE-Venture / Crompton / Bajaj/Halonix/Jaquar/HPL |
| 26 | Supply, fixing, testing & commissioning of 230V, 1200mmceiling fans five star rating(power consumption 50W or less than 50W) of approved brand in Ivory /brown /white colour, complete with all material, labour tools & tackles as directed by Engineer in charge. BRANDS: BAJAJ / C.G/ USHA / POLAR/ KHIATAN/ALMONARD |
| 27 | Supply and fixing of1 module Modular type Step typeElectronic regulator. BRANDS: ANCHOR/ CONA / MK / POINTER / GOLD MEDAL OLIVE / MILLION ZOOM. |
| 28 | Supply, installation, testing and commissioning of 1.5 Ton capacity High Wall Spilt Air Conditioners of 3 star or above rating with nominal cooling capacity 6500 K. Cal / Hr with hermetically sealed compressor with copper tube condenser suitable for wall mountingand other standard accessories like stand for outdoor unit etc., suitable to work on 230+/- 10% Volts, single phase AC supply capable of performing: a) Cooling, b) Dehumidifying, c) Ventilation, d) Air Circulating, e) Filtering, conforming to IS:1391(Part-2) - 1992 with up to date amendments. Including supply of electronic voltage 4KVA stabilizers to operate from 170-300 V ; 50 HZ ,single phase ACsupply with an output voltage of 240 +/- 5% V with auto shut off and time delay circuitry of reputed make Make for AC: Daikin / Carrier / Blue Star / Hitachi / Voltas/LLOYD. Make for Stabilizer: : keeline/v-guard/unistab |
| 29 | Fixing, testing and commissioning of 1.5 Ton capacity High Wall Spilt Air Conditioners as directed by engineer in charge including all labour tools and tackles. |
| 30 | Supply, fixing, connecting of 15-25 Amps,modular type, A.C starter (ON & OFF switch control) of approved brand on suitable surface/concealed boxincluding all labour and material as directed by Engineer in charge.BRANDS: KOLORS/ ANCHOR /KREST/ROMA EURO |
| 31 | Supply fixingtesting & commissioning of 12 – 15 W LED recess mounted round type in polycarbonate housing to work on Input voltage 180 - 270 V AC, P.F > 0.90, high power including driver and fixing the same to the ceiling as directed by engineer in charge including all labour tools and tackles.Makes: SURYA/FORTUNE ART / SYSKA / EVEREADY/ PHILIPS / BAJAJ/CG/Halonix |
| 32 | Supply fixingtesting & commissioning of 16-18 W LED recess mounted round type in polycarbonate housing to work on Input voltage 180 - 270 V AC, P.F > 0.90, high power including driver and fixing the same to the ceiling as directed by engineer in charge including all labour tools and tackles.Makes: SURYA/FORTUNE ART / SYSKA / EVEREADY/ PHILIPS / BAJAJ/CG/Halonix |
| 33 | Supply ,fixing connecting and commissioning of 50-60 LED High Bay Luminaire with high power COB LED made of pressure die-cast alluminium housing with powder coated, to work on Input voltage 180 - 270 V AC, P.F > 0.90, high power including driver and fixing the same to the ceiling with 5years warrenty.as directed by engineer in charge including all labour tools and tackles.Makes: SURYA/FORTUNE ART / SYSKA / EVEREADY/ PHILIPS / BAJAJ/CG/Halonix |
| 34 | Supply, fixing, testing and commissioning of LED street light fittings luminaries 25W-30W complete with all accessories including 1.5 Mtrs long (Approx) medium grade suitable dia GI bend pipe and 3 core 2.5 Sqmm flexible copper cable of required length to connect to the supply source as directed by Engineer-in-charge including all labour, tools, tackles and materials.Make: SURYA/FORTUNE ART / SYSKA / EVEREADY/PHILIPS / BAJAJ/CG/Halonix |
| 35 | Supply installation, testing and commissioning of 15 KVA, 415 Volts, 50Hz, 3 phase, water cooled multi cylinder diesel generator set with Diesel engine prime mover and Alternator of reputed make along with PLC based AMF panel. The DG Set shall be mounted on a common base plate of robust construction in acoustic enclosure as per the detailed specifications mentioned in the Annexure.Note: The above scope of supply includes transportation, arrangement loading, unloading including first filling of Diesel oil and lube oil for 12 Hrs operations.Prime Mover Brands: Kirloskar/ Greaves/ Caterpiller/ Mahindra/ Cummins/ Volva/ Perkins/ Powerica..Alternator Brands: Kirloskar/ CG/ Stamford. |
| 36 | Supply and Laying / clamping of 110 mm dia HDPE pipe of PE 80 Grade confirms to ISI in the existing in trench complete as directed by Engineer in charge including all labour and material.Make: Tulasi / Sudhakar / Nandi |
| 37 | Providing, earth station using 1.8 meters long, 80 mmC.I. pipe in a masonry enclosure duly filling with alternate layers of salt and charcoal complete with GI funnel and covering with RCC cover conforming to IS as directed by Engineer in charge including all labour and material. |
| 38 | Supply and fixing / running of 50 x5 mm GI earth strip including connecting as open/recessed/clamped to the pole/mains as directed by engineer in charge including all labour , tools and tackles. |
| 39 | Supply and fixing/running of GI wire 08 SWG in double run including connecting the same with switch gear and earth point as open/recessed/clamped to the wall/pole as directed by Engineer in charge including all labour tools and tackles. |
| 40 | Supply and providing of P.C.C. 1:3:6 with 20 mm graded granite as coarse aggregate and river sand as fine aggregate (220 Kgs of cement per M3of finished concrete) including mixing, depositing in position, tamping, finishing and curing for base/pole concreting, road cutting etc. as directed by engineer in charge including all labour and tools. |
| 41 | Excavation of trenches of required width for laying of GI pipes, cables etc., including dressing of sides, ramming of bottoms, suitable depth including getting out the excavated soil and the returning the soil including consolidating each deposit layer by ramming, watering etc., and disposing of surplus excavated soil as directed by engineer in charge and complete all labour and material:Hard/dense soil |
| 42 | Excavation of trenches of required width for laying of GI pipes, cables etc., including dressing of sides, ramming of bottoms, suitable depth including getting out the excavated soil and the returning the soil including consolidating each deposit layer by ramming, watering etc., and disposing of surplus excavated soil as directed by engineer in charge and complete all labour and material Soft / Loose soil |
| 43 | Excavation CC block road surface / CC road with Pneumatic hammer Or JCB machine of required width and depth for laying of GI pipes, HDPE pipe , cables erection of BG /PSCC pole etc., and making of the surface good to match with surrounding as directed by engineer in charge and complete all labour and material Hard / dense soil |
| 44 | Supply and fabrication of steel by using suitable flats, angles, channels of required sizes to provide required cross arms, back clamps, support clamps, frames including cutting, bolting, riveting, drilling, welding etc. including providing one coat of zinc rich epoxy paint primer complete as directed by Engineer in charge. |
| 45 | Transportation and erection of 4 Mtr. height(approx)S/H B G Rail poles in the existing trench duly welded with existing base plate to provide barricade theswitch yards including one coat silver paint over two coat red oxide paint as directed by Engr. I/c including all labour tools, tackles transportation loading and un loading. Note: Rail Pole will be supplied by VPT at free of cost. |
| 46 | Providing and fixing G.I tublar gate (double shutters) with 40 mm dia, G.I. pipe and specials including diagonal pipes and frame welded to approved weld mesh of 75 x 25 mm size (3.15 mm x 5 mm dia) including painting with one priming coat and two coats of synthetic enamel paint of approved colour and shade (total three coats) etc., with locking arrangement, necessary MS flats, iron pintels etc., including fixing in CC bed block as directed with 12 mm dia, bolts and nuts, washers etc., as required complete with all material, tools tackles as directed by Engineer- in- charge |
| 47 | Supplying and fixing galvanized steel chain link mesh of 50 mm x 50 mm openings and 10 gauge as per IS 2721-1979 including bending, tying with G.I. wire / welding etc., as directed by the EIC complete with all material, tools tackles as directed by Engineer- in- charge. |
| 48 | Providing random rubble masonry in C.M 1:5 in plinth and foundations including necessary dressed stones at corners and junctions, curing etc., complete. All labour and materials. |
| 49 | Providing plastering with CM 1:6, 12 mm thick including raking out joints, cleaning the surface, curing etc., complete all labour and materials |
| 50 | Supply and spreading of crusher dust at site of work including stacking and spreading in layers completion with hand roller and with rammers complete with all labour tools and tackles as directed by Engineer I/c |
| 51 | Supply and spreadingof 20 mm granite metal including hand packing to proper camber compaction with hand roller and with rammers complete with all labour tools and tackles as directed by Engineer I/c |
| 52 | Supply and spreadingof 40 mm granite metal including hand packing to proper camber compaction with hand roller and with rammers complete with all labour tools and tackles as directed by Engineer I/c |
| 53 | Supply and spreadingGravel or moorumincluding hand packing to proper camber compaction with hand roller and with rammers complete with all labour tools and tackles as directed by Engineer I/c |
| 54 | Providing of Horizontal bore(Auguring) at road crossings or any locationspertains to the work at a depth of not less than 1Mtr. (Approx)with core drilling machine to provide suitable size GI / HDPE pipe for drawing of Electrical cables at road crossings as directed with all machinery labour tools and tackles. including labour materials tool and tackles as directed by Engg. I/c. |
| 55 | Painting of BG rail poles / MS poles / Tubular poles duly preparing the surface by scrapping / wire brushing etc. with two coat of Alluminum paint over two coat of red oxide and providing of pole numbers including supply of required paints with all materials labour tools and tackles as directed by Engr. I/c. |
| 56 | Providing brick work in CM 1: in plinth and foundations using approved quality standard bricksof class designation 35 icluding curing etc. complete with all material andlabour as directed by Engr. I/c |