| 1 | 1 | R2-CS-RW-10 Removing Existing Manglore tiles/AC/GI/Galvalume Sheets/polycarbonate plain and corrugated sheets from roof / cladding / partitions etc., excluding supporting structure but including scaffolding,handling, transporting,sorting and stacking at site lead up to 150m andor disposing etc complete as directed.The basic rate shall be reduced by 24/-per Sq.m for non stacking or if sheets removed by breaking. | A1 | 5000 | Sq.M. |
|---|
| 2 | 2 | R2-CS-RW-04 Providing and fixing 6 mm thick Non-asbestos high impact Polypropylene reinforced cement corrugated sheet of approved make conforming to IS: 14871-2000 laying the same in position as per the stipulation in IS: 3007-1991 using 8m dia polymer coated iron L or J hook bolts, galvanized iron & bituminous washers, or self drilling fasteners and EPDM washers, galvanized iron clamps, nuts and bolts etc. complete and as directed.\n(Net Area covered by sheeting will be measured. Laps will not be paid separately) | A2 | 5000 | Sq.M. |
|---|
| 3 | 3 | R2-CS-RW-07-a Providing and fixing non-asbestos fiber cement high impact polypropylene reinforced roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts,G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete as directed.Corrugated serrated adjustable ridges\n\n | A3 | 400 | Rmt |
|---|
| 4 | 4 | R2-CS-SS-01 Providing, detailing, fabricating and fixing at desired location using hot rolled sections and MS Plates of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), transporting to site and erecting structural steel members for all heights & at all levels including provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary fixtures and operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding and removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. (The qty. for this item shall be measured for gusset plates, base plates, bolts in M.T.) | A4 | 2 | MT |
|---|
| 5 | 5 | R2-CS-RW-08 Providing and fixing in position UV resistant, fire retardant, virtually unbreakable and temperature resistant (-40° C to +130° C) Polycarbonate corrugated sheet of 2mm thickness for roof of approved make to match the roof profile at any height with G.I. J hooks bolts of G.I. clamps nuts & bolts or with self drilling fastener and EPDM washer etc. complete as directed. | A5 | 250 | Sqm |
|---|
| 6 | 6 | R2-CS-RW-16-b Providing and fixing UV resistant selffit UPVC pipes of approved make for Rainwater downtakes confirming to IS 13592:1992 Type A suitable for 4kg/sqcm pressure for following pipe diameters including rain water receiving recess with pvc plug bend necessary fittings such as offsets shoes, fixing the pipes on wall with clips filling the joints with solvent/cement and necessary scafolding etc. complete as directed by Engineer In Charge.100mm dia | A6 | 1600 | Rmt |
|---|
| 7 | 7 | R2-CS-RW-13 Galvanised iron sheet 1 mm (20 B.W.G.) eaves precoated gutter 200 mm to 230 mm wide and 100 mm to 125 mm deep moulded or half round girth upto 600mm including iron rods, on the edges (throughout the length) and galvanised iron sheet ferrules with fixtures, for outlets wherever required clamped using W.I. clamp 38 mm x 3 mm fixed 1.0 m C/C including making necessary connections with rain water pipes etc complete and as directed. | A7 | 400 | Rmt |
|---|