| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-03-2021 | Corrigendum | Date | 22-03-2021 |
| Name of Work: Construction of Auditorium Building at CET,Ghatika, Bhubaneswar | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORKS | BI01010001010000000000000515BI0100001112 | ||
| 2 | 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings as required and removal of the same up to a distance of 1km outside the periphery with site leveling as directed by the Engineer- in- charge. | BI01010001010000000000000515BI0100001113 | 17250 | SQM |
| 3 | 3 | Earth work in excavation of foundation trenches by mechanical means (Hydraulic Excavator) / manually including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete in all respect excluding GST as directed by the Engineer- in- charge. | BI01010001010000000000000515BI0100001114 | ||
| 4 | 3.01 | HARD SOIL EXCAVATION | BI01010001010000000000000515BI0100001115 | ||
| 5 | 3.02 | UPTO 1.5 MTR(building) | BI01010001010000000000000515BI0100001116 | 2055.39 | CUM |
| 6 | 3.03 | UPTO 1.5 MTR(GATE COMPLEX) | BI01010001010000000000000515BI0100001117 | 1957.91 | CUM |
| 7 | 3.04 | STONY EARTH EXCAVATION | BI01010001010000000000000515BI0100001118 | ||
| 8 | 3.05 | 1.5 MTR TO 3.0 MTR | BI01010001010000000000000515BI0100001119 | 268.65 | CUM |
| 9 | 3.06 | 3.0 MTR TO 4.5 MTR | BI01010001010000000000000515BI0100001120 | 17.93 | CUM |
| 10 | 4 | Disposal of surplus excavated materials within the area specified & directed by BDA / EIC (all kinds of soil, boulders, concrete or any other excavated materials) including all lifts, spreading in layers, breaking clods and leveling to disposal ground arranged by the contractor inclusive from the site of excavation to the site of disposition(upto take 10 Km.) etc. complete in all respect excluding GST as directed by the Engineer- in- charge. | BI01010001010000000000000515BI0100001121 | ||
| 11 | 4.01 | LVL +150( Building) | BI01010001010000000000000515BI0100001122 | 2341.97 | CUM |
| 12 | 4.02 | Gate Complex | BI01010001010000000000000515BI0100001123 | 1957.91 | CUM |
| 13 | 5 | Supplying & Filling foundation trenches , plinth & ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties of all Materials, cost of all Labour,Sundries, T&P required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge. (Measurement will be taken on finished compacted section only.) | BI01010001010000000000000515BI0100001124 | ||
| 14 | 5.01 | Auditorium | BI01010001010000000000000515BI0100001125 | 3611.97 | CUM |
| 15 | 5.02 | Gate Complex | BI01010001010000000000000515BI0100001126 | 893.93 | CUM |
| 16 | 6 | Providing & laying Plain Cement concrete (PCC ) of proportion (1:3:6) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pump required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001127 | ||
| 17 | 6.01 | Auditorium | BI01010001010000000000000515BI0100001128 | ||
| 18 | 6.02 | BELOW PLINTH LVL. +150 | BI01010001010000000000000515BI0100001129 | 802.61 | CUM |
| 19 | 6.03 | ABOVE PLINTH | BI01010001010000000000000515BI0100001130 | ||
| 20 | 6.04 | LVL +3150 | BI01010001010000000000000515BI0100001131 | 3.04 | CUM |
| 21 | 6.05 | LVL +7050 | BI01010001010000000000000515BI0100001132 | 3.04 | CUM |
| 22 | 6.06 | LVL +10050 | BI01010001010000000000000515BI0100001133 | 3.04 | CUM |
| 23 | 6.07 | Gate Complex | BI01010001010000000000000515BI0100001134 | 23.93 | CUM |
| 24 | 7 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional anti- termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. complete in all respect as per specification as directed by the Engineer -in -charge. | BI01010001010000000000000515BI0100001135 | 4212 | SQM |
| 25 | 7.01 | a) Treatment to soil below raft: Before laying the rubble soling and pcc the compacted and leveled soil shall be treated at 5 litre / sq.m. | BI01010001010000000000000515BI0100001136 | ||
| 26 | 7.02 | b)Treatment to soil along the retaining wall:The soil coming in contact with the retaining wall shall be treated at 5 litre per sq. m. The treatment shall follow the backfilling as backfilling is done in stages of 30 cms but not to exceed a depth of 1metre. Rodding may be carried out to facilitate the treatment. | BI01010001010000000000000515BI0100001137 | ||
| 27 | 7.03 | c)Treatment to soil along the external perimeter of the building:The soil around the external perimeter of the building up to a depth of 30 cm shall be treated at 2.25 litres per linear metre. Rodding may be carried out to facilitate this treatment. | BI01010001010000000000000515BI0100001138 | ||
| 28 | 7.04 | d) Treatment of soil surrounding pipes, wastes and conduits:When pipes, wastes and conduits enter the soil inside the area of the foundation, the soil surrounding the point of entry must be loosened around each such pipe, waste or conduit for a distance of 15 cm and upto a depth of 7.5cm and loosened soil shall be treated with chemical emulsion. | BI01010001010000000000000515BI0100001139 | ||
| 29 | 7.05 | e)Spraying equipment:A pressure pump shall be used to carry out spraying operations to facilitate proper distribution of chemical in the soil. | BI01010001010000000000000515BI0100001140 | ||
| 30 | 7.06 | Note: All the Anti-termite treatment shall be executed through a recognised agency approved by the Engineer-in-charge. A written guarantee on non-judicial stamp paper shall be submitted by the Contractor for a minimum period of 10( Ten ) years from the certified date of completion for the satisfactory performance of the entire Anti-termite treatment system. The Defect Liability Period of the Anti-termite treatment is Ten years.The contractor has to furnish bank guarantee amounting to Rs. 4,00,000/- which will be released after 10(Ten) years from the date of completion of the whole work. In case,the contactor fails to furnish the B.G.,equal amont i.e. Rs. 4,00,000/- will be kept withheld from the Security Deposit till the end of the Defect Liability Period. | BI01010001010000000000000515BI0100001141 | ||
| 31 | 8 | Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 Grade in all type of Concrete works( i.e footing, Plinth Band, Lintels, Chajja, Shelf fins, Roof slabs, Balconies, Staircase, Column, Beam Parapets, Window sills, Lofts, Railings etc. ) as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of required steel centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GST as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001142 | ||
| 32 | 8.01 | BELOW PLINTH LVL. | BI01010001010000000000000515BI0100001143 | ||
| 33 | 8.02 | Auditorium | BI01010001010000000000000515BI0100001144 | ||
| 34 | 8.03 | Footing | BI01010001010000000000000515BI0100001145 | 724.98 | CUM |
| 35 | 8.04 | Column up to Plinth | BI01010001010000000000000515BI0100001146 | 184.45 | CUM |
| 36 | 8.05 | Plinth Beam | BI01010001010000000000000515BI0100001147 | 344.18 | CUM |
| 37 | 8.06 | Gate Complex | BI01010001010000000000000515BI0100001148 | ||
| 38 | 8.07 | Footing | BI01010001010000000000000515BI0100001149 | 128.94 | CUM |
| 39 | 8.08 | Plinth Beam | BI01010001010000000000000515BI0100001150 | 8.37 | CUM |
| 40 | 8.09 | ABOVE PLINTH LVL. | BI01010001010000000000000515BI0100001151 | ||
| 41 | 8.1 | LVL +150 | BI01010001010000000000000515BI0100001152 | ||
| 42 | 8.11 | Auditorium | BI01010001010000000000000515BI0100001153 | ||
| 43 | 8.12 | Column above plinth to FF | BI01010001010000000000000515BI0100001154 | 442.69 | CUM |
| 44 | 8.13 | Lintel | BI01010001010000000000000515BI0100001155 | 6.58 | CUM |
| 45 | 8.14 | Slab | BI01010001010000000000000515BI0100001156 | 988.8 | CUM |
| 46 | 8.15 | Stair case | BI01010001010000000000000515BI0100001157 | 158.48 | CUM |
| 47 | 8.16 | Gate Complex | BI01010001010000000000000515BI0100001158 | ||
| 48 | 8.17 | Column & Beam | BI01010001010000000000000515BI0100001159 | 25.92 | CUM |
| 49 | 8.18 | Lintel | BI01010001010000000000000515BI0100001160 | 0.46 | CUM |
| 50 | 8.19 | Slab | BI01010001010000000000000515BI0100001161 | 27 | CUM |
| 51 | 8.2 | LVL +3150 | BI01010001010000000000000515BI0100001162 | ||
| 52 | 8.21 | Column | BI01010001010000000000000515BI0100001163 | 385.15 | CUM |
| 53 | 8.22 | Lintel | BI01010001010000000000000515BI0100001164 | 6.58 | CUM |
| 54 | 8.23 | Roof Beam | BI01010001010000000000000515BI0100001165 | 516.27 | CUM |
| 55 | 8.24 | Slab | BI01010001010000000000000515BI0100001166 | 974.7 | CUM |
| 56 | 8.25 | Stair case | BI01010001010000000000000515BI0100001167 | 158.48 | CUM |
| 57 | 8.26 | LVL +7050 | BI01010001010000000000000515BI0100001168 | ||
| 58 | 8.27 | Column | BI01010001010000000000000515BI0100001169 | 224.59 | CUM |
| 59 | 8.28 | Lintel | BI01010001010000000000000515BI0100001170 | 6.58 | CUM |
| 60 | 8.29 | Roof Beam | BI01010001010000000000000515BI0100001171 | 202.93 | CUM |
| 61 | 8.3 | Slab | BI01010001010000000000000515BI0100001172 | 515.95 | CUM |
| 62 | 8.31 | Stair case | BI01010001010000000000000515BI0100001173 | 158.48 | CUM |
| 63 | 8.32 | LVL +10050 | BI01010001010000000000000515BI0100001174 | ||
| 64 | 8.33 | Column | BI01010001010000000000000515BI0100001175 | 224.59 | CUM |
| 65 | 8.34 | Lintel | BI01010001010000000000000515BI0100001176 | 6.58 | CUM |
| 66 | 8.35 | Roof Beam | BI01010001010000000000000515BI0100001177 | 202.93 | CUM |
| 67 | 8.36 | Slab | BI01010001010000000000000515BI0100001178 | 515.95 | CUM |
| 68 | 8.37 | Stair case | BI01010001010000000000000515BI0100001179 | 158.48 | CUM |
| 69 | 8.38 | LVL +14850 | BI01010001010000000000000515BI0100001180 | ||
| 70 | 8.39 | Column | BI01010001010000000000000515BI0100001181 | 171.05 | CUM |
| 71 | 8.4 | Roof Beam | BI01010001010000000000000515BI0100001182 | 170.29 | CUM |
| 72 | 8.41 | Slab | BI01010001010000000000000515BI0100001183 | 358.7 | CUM |
| 73 | 9 | Providing & fixing Thermo mechanically treated bars (Fe-500 D) Reinforcement bars of approved make for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyance of reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour, loading, unloading, labour cess, T&P, etc. required for the work complete for the work in all heights as per the specification & excluding GST as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement) | BI01010001010000000000000515BI0100001184 | ||
| 74 | 9.01 | Auditorium | BI01010001010000000000000515BI0100001185 | ||
| 75 | 9.02 | LVL +150 | BI01010001010000000000000515BI0100001186 | 4698.74 | QUINTAL |
| 76 | 9.03 | LVL +3150 | BI01010001010000000000000515BI0100001187 | 3316.2 | QUINTAL |
| 77 | 9.04 | LVL +7050 | BI01010001010000000000000515BI0100001188 | 1770.46 | QUINTAL |
| 78 | 9.05 | LVL +10050 | BI01010001010000000000000515BI0100001189 | 1770.46 | QUINTAL |
| 79 | 9.06 | LVL +14850 | BI01010001010000000000000515BI0100001190 | 1183.34 | QUINTAL |
| 80 | 9.07 | Gate Complex | BI01010001010000000000000515BI0100001191 | 230.6 | QUINTAL |
| 81 | 9.08 | Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use ,including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect excluding GST as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001192 | ||
| 82 | 9.09 | BELOW PLINTH LVL. | BI01010001010000000000000515BI0100001193 | 1912.1 | CUM |
| 83 | 9.1 | ABOVE PLINTH LVL. | BI01010001010000000000000515BI0100001194 | ||
| 84 | 9.11 | Auditorium | BI01010001010000000000000515BI0100001195 | ||
| 85 | 9.12 | LVL +150 | BI01010001010000000000000515BI0100001196 | 366.08 | CUM |
| 86 | 9.13 | LVL +3150 | BI01010001010000000000000515BI0100001197 | 269.82 | CUM |
| 87 | 9.14 | LVL +7050 | BI01010001010000000000000515BI0100001198 | 273.12 | CUM |
| 88 | 9.15 | LVL +10050 | BI01010001010000000000000515BI0100001199 | 273.12 | CUM |
| 89 | 9.16 | LVL +14850 | BI01010001010000000000000515BI0100001200 | 134.24 | CUM |
| 90 | 9.17 | Gate Complex | BI01010001010000000000000515BI0100001201 | 13.62 | CUM |
| 91 | 10 | Fly ash Brick masonry work using Fly ash. Bricks having crushing strength not less than 75kg/sqcm in cement mortar (1:4) for half brick (125mm) masonry walls in superstructure with provision of 2 nos.of 8mm M.S. round reinforcement bars at each 4th layer after immersing the bricks for 6 hours in water before use in superstructure and similar type of work with necessary projections, splay, cutting, circular, moulding, corbeling, watering curing scaffolding, ncluding cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect excluding GST as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001202 | ||
| 92 | 10.01 | Auditorium | BI01010001010000000000000515BI0100001203 | ||
| 93 | 10.02 | LVL +150 | BI01010001010000000000000515BI0100001204 | 22.61 | CUM |
| 94 | 10.03 | LVL +3150 | BI01010001010000000000000515BI0100001205 | 10.05 | CUM |
| 95 | 10.04 | LVL +7050 | BI01010001010000000000000515BI0100001206 | 6.69 | CUM |
| 96 | 10.05 | LVL +10050 | BI01010001010000000000000515BI0100001207 | 6.69 | CUM |
| 97 | 10.06 | Gate Complex | BI01010001010000000000000515BI0100001208 | 1.67 | CUM |
| 98 | 11 | 6 m.m thick cement plaster in cement mortar of mix (1:4) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respect excluding GST as directed by the Engineer- in- charge. | BI01010001010000000000000515BI0100001209 | ||
| 99 | 11.01 | Auditorium | BI01010001010000000000000515BI0100001210 | ||
| 100 | 11.02 | LVL +150 | BI01010001010000000000000515BI0100001211 | 2076.96 | SQM |
| 101 | 11.03 | LVL +3150 | BI01010001010000000000000515BI0100001212 | 2762.8 | SQM |
| 102 | 11.04 | LVL +7050 | BI01010001010000000000000515BI0100001213 | 2071.45 | SQM |
| 103 | 11.05 | LVL +10050 | BI01010001010000000000000515BI0100001214 | 1429.23 | SQM |
| 104 | 11.06 | LVL +14850 | BI01010001010000000000000515BI0100001215 | 204.28 | SQM |
| 105 | 11.07 | Gate Complex | BI01010001010000000000000515BI0100001216 | 180 | SQM |
| 106 | 12 | 12 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete in all respect excluding GST as directed by the Engineer- in- charge. | BI01010001010000000000000515BI0100001217 | ||
| 107 | 12.01 | Auditorium | BI01010001010000000000000515BI0100001218 | ||
| 108 | 12.02 | LVL +150 | BI01010001010000000000000515BI0100001219 | 2343.9 | SQM |
| 109 | 12.03 | LVL +3150 | BI01010001010000000000000515BI0100001220 | 4508.32 | SQM |
| 110 | 12.04 | LVL +7050 | BI01010001010000000000000515BI0100001221 | 3147.38 | SQM |
| 111 | 12.05 | LVL +10050 | BI01010001010000000000000515BI0100001222 | 3804.9 | SQM |
| 112 | 12.06 | LVL +14850 | BI01010001010000000000000515BI0100001223 | 1487.73 | SQM |
| 113 | 12.07 | Gate Complex | BI01010001010000000000000515BI0100001224 | 248.94 | SQM |
| 114 | 13 | Finishing wall surface of walls with cement based wall putty ( water based) of approved make and finishing the surface smooth by sand papering to receive paint in all floor & at all heights including cost, coveyance, loading , unloading ,stacking of all Materials, cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001225 | ||
| 115 | 13.01 | Auditorium | BI01010001010000000000000515BI0100001226 | ||
| 116 | 13.02 | LVL +150 | BI01010001010000000000000515BI0100001227 | 3533.46 | SQM |
| 117 | 13.03 | LVL +3150 | BI01010001010000000000000515BI0100001228 | 5913.14 | SQM |
| 118 | 13.04 | LVL +7050 | BI01010001010000000000000515BI0100001229 | 3800.29 | SQM |
| 119 | 13.05 | LVL +10050 | BI01010001010000000000000515BI0100001230 | 2833.83 | SQM |
| 120 | 13.06 | LVL +14850 | BI01010001010000000000000515BI0100001231 | 1019.44 | SQM |
| 121 | 13.07 | Gate Complex | BI01010001010000000000000515BI0100001232 | 428.94 | SQM |
| 122 | 14 | Providing two coats of plastic emulsion paint of approved quality and colour over a coat priming over plastered wall surface using the required quantity of paint as specified by the manufacturer to give an even shade over the finished plaster surface including watering the surface before applying and period including cost, coveyance, loading , unloading ,stacking of all Materials, cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001233 | ||
| 123 | 14.01 | Auditorium | BI01010001010000000000000515BI0100001234 | ||
| 124 | 14.02 | LVL +150 | BI01010001010000000000000515BI0100001235 | 3533.46 | SQM |
| 125 | 14.03 | LVL +3150 | BI01010001010000000000000515BI0100001236 | 5913.14 | SQM |
| 126 | 14.04 | LVL +7050 | BI01010001010000000000000515BI0100001237 | 3800.29 | SQM |
| 127 | 14.05 | LVL +10050 | BI01010001010000000000000515BI0100001238 | 2833.83 | SQM |
| 128 | 14.06 | LVL +14850 | BI01010001010000000000000515BI0100001239 | 1019.44 | SQM |
| 129 | 14.07 | Gate Complex | BI01010001010000000000000515BI0100001240 | 428.94 | SQM |
| 130 | 15 | Finishing walls with textured exterior paint of required shade of two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm of approved make after cleaning by watering & removung the dirts etc.to the surface to be painted including watering ,curing,cost,conveyance of all material cost of all labour,brushes ,T& P etc and necessary scaffolding work complete in all respect excluding GST as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001241 | ||
| 131 | 15.01 | Auditorium | BI01010001010000000000000515BI0100001242 | ||
| 132 | 15.02 | LVL +150 | BI01010001010000000000000515BI0100001243 | 887.4 | SQM |
| 133 | 15.03 | LVL +3150 | BI01010001010000000000000515BI0100001244 | 1357.98 | SQM |
| 134 | 15.04 | LVL +7050 | BI01010001010000000000000515BI0100001245 | 1418.54 | SQM |
| 135 | 15.05 | LVL +10050 | BI01010001010000000000000515BI0100001246 | 2400.3 | SQM |
| 136 | 15.06 | LVL +14850 | BI01010001010000000000000515BI0100001247 | 672.57 | SQM |
| 137 | 15.07 | Gate Complex | BI01010001010000000000000515BI0100001248 | 124.47 | SQM |
| 138 | 16 | Providing , Fitting & Fixing 16 mm thick Kota stone tile (above.10sqm) in flooring using special grade of Kota stone tile confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings in all floors at all height on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the kota stone tile with neat white cement slurry, including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect excluding GST as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001249 | ||
| 139 | 16.01 | Auditorium | BI01010001010000000000000515BI0100001250 | ||
| 140 | 16.02 | LVL +150 | BI01010001010000000000000515BI0100001251 | 1589.87 | SQM |
| 141 | 16.03 | LVL +3150 | BI01010001010000000000000515BI0100001252 | 453.48 | SQM |
| 142 | 16.04 | LVL +7050 | BI01010001010000000000000515BI0100001253 | 485.88 | SQM |
| 143 | 16.05 | LVL +10050 | BI01010001010000000000000515BI0100001254 | 485.88 | SQM |
| 144 | 16.06 | LVL +14850 | BI01010001010000000000000515BI0100001255 | 202.88 | SQM |
| 145 | 16.07 | Gate Complex | BI01010001010000000000000515BI0100001256 | 20.25 | SQM |
| 146 | 17 | Providing, Fitting & Fixing 25 mm thik kota stone of approved quality and make confirming to IS specifications having minimum breaking strength 1400 kg/sq.cm in dados and skirting in all floors at all heights on 12mm thick bed of cement mortar(1:3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading, unloading, stacking,royalties of all materials, cost of all labour, T & P, sundries, watering & curing etc. required for the work complete in all respect excluding GST as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001257 | ||
| 147 | 17.01 | Auditorium | BI01010001010000000000000515BI0100001258 | ||
| 148 | 17.02 | LVL +150 | BI01010001010000000000000515BI0100001259 | 105.2 | SQM |
| 149 | 17.03 | LVL +3150 | BI01010001010000000000000515BI0100001260 | 52.32 | SQM |
| 150 | 17.04 | LVL +7050 | BI01010001010000000000000515BI0100001261 | 62.67 | SQM |
| 151 | 17.05 | LVL +10050 | BI01010001010000000000000515BI0100001262 | 62.67 | SQM |
| 152 | 17.06 | LVL +14850 | BI01010001010000000000000515BI0100001263 | 25.34 | SQM |
| 153 | 17.07 | Gate Complex | BI01010001010000000000000515BI0100001264 | 2.7 | SQM |
| 154 | 18 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring in toilets using special plain / printed series anti-skid ceramic floor tile of premium grade (having minimum thickness 7 mm to 8 mm & size 300 mm x 300 mm or 400 mm x 400 mm ) confirming to I.S 13755 of approved quility and shade on 20mm thick ded of cement morter of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the anti-skid ceramic floor tiles with neat white cement slurry, mixed with required (tiles are to be immersed in the water for required time before use) quantities of pigments of approved marks to match the shades of the anti-skid ceramic floor tiles if required including cost, conveyance, loading, unloading, stacking, royalties of all material, cost of all labour , sundries, T&P required for the work , watering,complete in all respect as per specification excluding GST aas per specification as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) | BI01010001010000000000000515BI0100001265 | ||
| 155 | 18.01 | Auditorium | BI01010001010000000000000515BI0100001266 | ||
| 156 | 18.02 | LVL +150 | BI01010001010000000000000515BI0100001267 | 605.6 | SQM |
| 157 | 18.03 | LVL +3150 | BI01010001010000000000000515BI0100001268 | 90.4 | SQM |
| 158 | 18.04 | LVL +7050 | BI01010001010000000000000515BI0100001269 | 59 | SQM |
| 159 | 18.05 | LVL +10050 | BI01010001010000000000000515BI0100001270 | 59 | SQM |
| 160 | 18.06 | Gate Complex | BI01010001010000000000000515BI0100001271 | 3.15 | SQM |
| 161 | 19 | Providing & Fixing tiles of size 20 x 30cm glazed ceramic wall tiles of premium grade of approved quality and shade having thickness 8mm to 10mm confirming to IS 13755 in dados skirting and risers of steps on 12mm thick cement plaster (1:3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc including filling the joints with neat white cement slurry mixed with pigments to match the shade of the tiles including cost, conveyance,loading,unloading,stacking, royalities of all materials, cost of all labour,T&P, sundries, watering and curing for the required period for the work complete in all respect excluding GST as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) | BI01010001010000000000000515BI0100001272 | ||
| 162 | 19.01 | Auditorium | BI01010001010000000000000515BI0100001273 | ||
| 163 | 19.02 | LVL +150 | BI01010001010000000000000515BI0100001274 | 716.31 | SQM |
| 164 | 19.03 | LVL +3150 | BI01010001010000000000000515BI0100001275 | 116.34 | SQM |
| 165 | 19.04 | LVL +7050 | BI01010001010000000000000515BI0100001276 | 176.4 | SQM |
| 166 | 19.05 | LVL +10050 | BI01010001010000000000000515BI0100001277 | 176.4 | SQM |
| 167 | 19.06 | Gate Complex | BI01010001010000000000000515BI0100001278 | 13.99 | SQM |
| 168 | 20 | Supplying , fitting and Fixing Glazed vitrified Tile(GVT) flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 800mm x 800mm of approved quality, colour in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST as directed by Engineer-in-charge. (Note- Sample of tiles shall be approved before procurement and use.) | BI01010001010000000000000515BI0100001279 | ||
| 169 | 20.01 | LVL +150 | BI01010001010000000000000515BI0100001280 | 2216.94 | SQM |
| 170 | 20.02 | LVL +3150 | BI01010001010000000000000515BI0100001281 | 2148.7 | SQM |
| 171 | 20.03 | LVL +7050 | BI01010001010000000000000515BI0100001282 | 1419.47 | SQM |
| 172 | 20.04 | LVL +10050 | BI01010001010000000000000515BI0100001283 | 900.95 | SQM |
| 173 | 20.05 | LVL +14850 | BI01010001010000000000000515BI0100001284 | 947.16 | SQM |
| 174 | 21 | Supplying , fitting and Fixing Glazed vitrified Tile(GVT) in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 800mmx800mm of approved quality in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days,including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST and as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) | BI01010001010000000000000515BI0100001285 | ||
| 175 | 21.01 | LVL +150 | BI01010001010000000000000515BI0100001286 | 101.62 | SQM |
| 176 | 21.02 | LVL +3150 | BI01010001010000000000000515BI0100001287 | 80.05 | SQM |
| 177 | 21.03 | LVL +7050 | BI01010001010000000000000515BI0100001288 | 67.73 | SQM |
| 178 | 21.04 | LVL +10050 | BI01010001010000000000000515BI0100001289 | 51.2 | SQM |
| 179 | 21.05 | LVL +14850 | BI01010001010000000000000515BI0100001290 | 32.94 | SQM |
| 180 | 22 | Providing Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, ccolour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect excluding GST as directed by Engineer-in-charge(Note- Sample of tiles shall be approved before procurement and use.) | BI01010001010000000000000515BI0100001291 | ||
| 181 | 22.01 | LVL +150 | BI01010001010000000000000515BI0100001292 | 291.92 | SQM |
| 182 | 22.02 | LVL +3150 | BI01010001010000000000000515BI0100001293 | 1030 | SQM |
| 183 | 22.03 | LVL +7050 | BI01010001010000000000000515BI0100001294 | 96.16 | SQM |
| 184 | 22.04 | LVL +10050 | BI01010001010000000000000515BI0100001295 | 24.16 | SQM |
| 185 | 22.05 | LVL +14850 | BI01010001010000000000000515BI0100001296 | 10.8 | SQM |
| 186 | 23 | Providing edge moulding to 20 mm thick granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. including cost of all labour, T & P, sundries etc. required for the work complete in all respect excluding GST as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001297 | ||
| 187 | 23.01 | LVL +150 | BI01010001010000000000000515BI0100001298 | 399 | RMT |
| 188 | 23.02 | LVL +3150 | BI01010001010000000000000515BI0100001299 | 1295.56 | RMT |
| 189 | 23.03 | LVL +7050 | BI01010001010000000000000515BI0100001300 | 48.7 | RMT |
| 190 | 23.04 | LVL +10050 | BI01010001010000000000000515BI0100001301 | 84.35 | RMT |
| 191 | 23.05 | LVL +14850 | BI01010001010000000000000515BI0100001302 | 47.8 | RMT |
| 192 | 24 | Providing Granite stone prepolished 20mm thick in dado of approved quality, colour and size in dado/skirting , riser of steps in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respectexcluding GST as directed by the Engineer-in-Charge. .(Note- Sample of granite stoneshall be approved before procurement and use.) | BI01010001010000000000000515BI0100001303 | ||
| 193 | 24.01 | LVL +150 | BI01010001010000000000000515BI0100001304 | 27.54 | SQM |
| 194 | 24.02 | LVL +3150 | BI01010001010000000000000515BI0100001305 | 96.47 | SQM |
| 195 | 24.03 | LVL +7050 | BI01010001010000000000000515BI0100001306 | 22.77 | SQM |
| 196 | 24.04 | LVL +10050 | BI01010001010000000000000515BI0100001307 | 15.92 | SQM |
| 197 | 24.05 | LVL +14850 | BI01010001010000000000000515BI0100001308 | 13.67 | SQM |
| 198 | 25 | Supplying, fitting and fixing of M.S hand rail of approved size ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect excluding GST as per specification as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001309 | ||
| 199 | 25.01 | Auditorium | BI01010001010000000000000515BI0100001310 | ||
| 200 | 25.02 | RAMP | BI01010001010000000000000515BI0100001311 | ||
| 201 | 25.03 | LVL +150 | BI01010001010000000000000515BI0100001312 | 772.2 | KG |
| 202 | 25.04 | STAIR CASE | BI01010001010000000000000515BI0100001313 | ||
| 203 | 25.05 | LVL +150 | BI01010001010000000000000515BI0100001314 | 702 | KG |
| 204 | 25.06 | LVL +3150 | BI01010001010000000000000515BI0100001315 | 648 | KG |
| 205 | 25.07 | LVL +7050 | BI01010001010000000000000515BI0100001316 | 648 | KG |
| 206 | 25.08 | LVL +10050 | BI01010001010000000000000515BI0100001317 | 648 | KG |
| 207 | 25.09 | LVL +14850 | BI01010001010000000000000515BI0100001318 | 324 | KG |
| 208 | 25.1 | Gate Complex | BI01010001010000000000000515BI0100001319 | 3160 | KG |
| 209 | 26 | Providing and painting two coats with synthetic enamel paint on Iron work over a coat of Red Oxide Primer of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect excluding GST as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001320 | ||
| 210 | 26.01 | Auditorium | BI01010001010000000000000515BI0100001321 | ||
| 211 | 26.02 | LVL +150 | BI01010001010000000000000515BI0100001322 | 720.25 | SQM |
| 212 | 26.03 | LVL +3150 | BI01010001010000000000000515BI0100001323 | 25.92 | SQM |
| 213 | 26.04 | LVL +7050 | BI01010001010000000000000515BI0100001324 | 25.92 | SQM |
| 214 | 26.05 | LVL +10050 | BI01010001010000000000000515BI0100001325 | 25.92 | SQM |
| 215 | 26.06 | LVL +14850 | BI01010001010000000000000515BI0100001326 | 11.66 | SQM |
| 216 | 26.07 | Gate Complex | BI01010001010000000000000515BI0100001327 | 79 | SQM |
| 217 | 27 | Providing & fixing factory made single extruded WPC( Wood polymer Composite) solid door /windows/other frames/chowkhat comprising of virgin polymer of k value 58-60 (Suspension Grade),calcium carbonate and natural fibers( wood powder/rice husk/wheat husk) and non toxic addictives ( maximum toxicity index of 12 for 100gms)fabricated with miter joints after applying PVC Solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screws withdrawal stregth of 2200 N(Face) & 1100 N(Edge), minimum compresive strength 58N/mm2,modulus of elasticity 900 n/mm2 and resistance to spread of flame of Class A Category with property of being termite/borer proof,water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect excluding GST as directed by the Engineer-in-charge.( Note- MS hold fast/lugs or SS dash fastener shall be paid separately) | BI01010001010000000000000515BI0100001328 | ||
| 218 | 27.01 | Auditorium | BI01010001010000000000000515BI0100001329 | ||
| 219 | 27.02 | Frame size- 125x65mm | BI01010001010000000000000515BI0100001330 | ||
| 220 | 27.03 | LVL +150 | BI01010001010000000000000515BI0100001331 | 204 | MTR |
| 221 | 27.04 | LVL +3150 | BI01010001010000000000000515BI0100001332 | 21 | MTR |
| 222 | 27.05 | LVL +7050 | BI01010001010000000000000515BI0100001333 | 59.7 | MTR |
| 223 | 27.06 | LVL +10050 | BI01010001010000000000000515BI0100001334 | 59.7 | MTR |
| 224 | 27.07 | Gate Complex | BI01010001010000000000000515BI0100001335 | 10.7 | MTR |
| 225 | 28 | Providing & fixing factory made single extruded WPC( Wood polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of k value 58-60 (Suspension Grade),calcium carbonate and natural fibers( wood powder/rice husk/wheat husk) and non toxic addictives ( maximum toxicity index of 12 for 100gms) having minimum denisity of 650 kg/cum and screw withdrawal strength of 1800N(Face) & 900 N(Edge), minimum compresive strength 50N/mm2,modulus of elasticity 850 n/mm2 and resistance to spread of flame of Class A Category with property of being termite/borer proof,water/moisture proof and fire retardant and fixing with stainless steel (SS 304 Grade) butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect excluding GST as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001336 | ||
| 226 | 28.01 | Auditorium | BI01010001010000000000000515BI0100001337 | ||
| 227 | 28.02 | Thickness-30mm | BI01010001010000000000000515BI0100001338 | ||
| 228 | 28.03 | LVL +150 | BI01010001010000000000000515BI0100001339 | 50.4 | SQM |
| 229 | 28.04 | LVL +3150 | BI01010001010000000000000515BI0100001340 | 7.88 | SQM |
| 230 | 28.05 | LVL +7050 | BI01010001010000000000000515BI0100001341 | 15.75 | SQM |
| 231 | 28.06 | LVL +10050 | BI01010001010000000000000515BI0100001342 | 15.75 | SQM |
| 232 | 28.07 | Gate Complex | BI01010001010000000000000515BI0100001343 | 2.21 | SQM |
| 233 | 29 | Providing & fixing factory made single extruded WPC( Wood polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of k value 58-60 (Suspension Grade),calcium carbonate and natural fibers( wood powder/rice husk/wheat husk) and non toxic addictives ( maximum toxicity index of 12 for 100gms) having minimum denisity of 650 kg/cum and screw withdrawal strength of 1800N(Face) & 900 N(Edge), minimum compresive strength 50N/mm2,modulus of elasticity 850 n/mm2 and resistance to spread of flame of Class A Category with property of being termite/borer proof,water/moisture proof and fire retardant including teak wood leaping on all edges. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel (SS 304 Grade) butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect excluding GST as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001344 | ||
| 234 | 29.01 | Auditorium | BI01010001010000000000000515BI0100001345 | ||
| 235 | 29.02 | Thickness-30mm | BI01010001010000000000000515BI0100001346 | ||
| 236 | 29.03 | LVL +150 | BI01010001010000000000000515BI0100001347 | 25.2 | SQM |
| 237 | 29.04 | LVL +3150 | BI01010001010000000000000515BI0100001348 | 11.22 | SQM |
| 238 | 29.05 | LVL +7050 | BI01010001010000000000000515BI0100001349 | 5.04 | SQM |
| 239 | 29.06 | LVL +10050 | BI01010001010000000000000515BI0100001350 | 5.04 | SQM |
| 240 | 29.07 | Gate Complex | BI01010001010000000000000515BI0100001351 | 1.47 | SQM |
| 241 | 30 | SYNTHETIC ENAMEL PAINT FOR WPC WORKPainting with synthetic enamel paint (for WPC Work) of approved colour, shade and brand on New wood work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including sand papering and making the surface smooth with cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete in all respect excluding GST as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001353 | ||
| 242 | 30.01 | Auditorium | BI01010001010000000000000515BI0100001354 | ||
| 243 | 30.02 | LVL +150 | BI01010001010000000000000515BI0100001355 | 127.91 | SQM |
| 244 | 30.03 | LVL +3150 | BI01010001010000000000000515BI0100001356 | 27.17 | SQM |
| 245 | 30.04 | LVL +7050 | BI01010001010000000000000515BI0100001357 | 37.1 | SQM |
| 246 | 30.05 | LVL +10050 | BI01010001010000000000000515BI0100001358 | 37.1 | SQM |
| 247 | 30.06 | Gate Complex | BI01010001010000000000000515BI0100001359 | 10.08 | SQM |
| 248 | 31 | Providing and fixing Approved Automatic sliding door Operator DORMA Make, Model ES 200 complete with operator profile, mechanical component, Electrical components, glass clamping rail 2nos, floor guide 2nos, ECW8 Sensor 2 nos.,light barrier SBK III (1 Pair ),Five position switch with knob, cable for program switch , Electromagnetic lock, including sliding glass, fixed Mannet 12mm glass , Mannet adjustable 12mm glass,BR Soft Nose seal, RP 49 with 50mm brush profile including cost and conveyance of all materials, cost of all labour, hire and running charges of machinaries, T&P etc. required for the work complete in all respect excluding GST as directed by Engineer-in-charge | BI01010001010000000000000515BI0100001360 | ||
| 249 | 31.01 | SIZE- 2.4M X 2.4M | BI01010001010000000000000515BI0100001361 | ||
| 250 | 31.02 | LVL +3150 | BI01010001010000000000000515BI0100001362 | 2 | SET |
| 251 | 32 | Supplying steel Fire shutter with Fire Rating of 120 minutes rating as per manufacturers specifications and similar to the prototype tested by CBRI, Roorkee & certificate issued thereof (as per IS:3614 Part-2, 1992) with overall size as per site requirement. Door frame are made with 1.6mm thick Galvanized steel sheet pressed to Double rebate profile of size 150 X 65 mm. Door shutter are made with 1.25mm thick Galvanized steel sheet pressed formed to provide a 55mm thick fully flush double skin panel shall with lock seam joints at style edges and filled with ceramic wool (96 kg/cum density) Honey comb structure with reinforcement at top, bottom and stile surrounds. The items also include provision for required iron mongery and finished with zinc phosphate storing primer & Powder coated finish including cost and conveyance of all materials, cost of all labour, hire and running charges of machinaries, T&P etc. required for the work complete in all respect excluding GST as directed by Engineer-in-charge. ( Door with Frame & Shutter: 1500 x 2250 mm, Double Shutter Door HARDWARE DETAILS HINGES: SS Ball bearing Butt Hinges 4\"x3\"x3 mm - Garg DEAD LOCK: 1 Side key and other side thumb turn, 80mm cylinder - Dauerhaft D HANDLE: SS 304 Grade, 22mm dia, 300mm Long - Dauerhaft ) \n | BI01010001010000000000000515BI0100001363 | ||
| 252 | 32.01 | DOOR CLOSER: Surface mounted std arm - Dauerhaft VISON PANEL: 7.2mm thick 200x300mm wired glass-Saintgobin CONCEALED FLUSH BOLT: 300 mm Long - Dauerhaft\n | BI01010001010000000000000515BI0100001364 | ||
| 253 | 32.02 | LVL +150 | BI01010001010000000000000515BI0100001365 | 17 | NOS |
| 254 | 32.03 | LVL +3150 | BI01010001010000000000000515BI0100001366 | 10 | NOS |
| 255 | 32.04 | LVL +7050 | BI01010001010000000000000515BI0100001367 | 12 | NOS |
| 256 | 32.05 | LVL +10050 | BI01010001010000000000000515BI0100001368 | 12 | NOS |
| 257 | 32.06 | LVL +14850 | BI01010001010000000000000515BI0100001369 | 4 | NOS |
| 258 | 33 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231(Part 3):2016 and as per direction of Engineer-in-charge. The glass should be clear, toughened, interlayered, non-wired fire resistant having minimum 11 mm thickness CFDL of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of =37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer Saint Gobain or Equivalant. (Actual glass size is to be measured at site for payments). | BI01010001010000000000000515BI0100001370 | ||
| 259 | 33.01 | LVL +150 | BI01010001010000000000000515BI0100001372 | 20.4 | SQM |
| 260 | 34 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). | BI01010001010000000000000515BI0100001373 | ||
| 261 | 34.01 | LVL +150 | BI01010001010000000000000515BI0100001374 | 36.2 | MTR |
| 262 | 35 | ACOUSTIC DOOR:Supply, fitting & fixing in position 70 mm thick, fabricated from 2.0mm thick steel sheet filled with sound absorbing and damping elements. Leaf shall be internally reinforced to accept hardware.Frame- Architectural split frame shall be fabricated from 2.0mm thick steel sheets, channels and plates and to be filled with sound absorbing and damping elements. Additional structural elements incorporated into the builders’ wall may be required to support the door assembly, please refer to IAC Acoustics for more information.Acoustic Seals - Side and head of door and frame shall each receive two sets of acoustic seals. An acoustic labyrinth shall be created when door is in closed position. Bottom of door leaf shall contain continuous gravity-activated seal which shall compress against steel threshold as door is closed.Pre-hung -Assembly and adjustment of door leaf, frame, acoustic seals and hinges shall take place at factory to ensure ease of installation, reliable operation and maintenance of acoustic performance. | BI01010001010000000000000515BI0100001375 | ||
| 263 | 35.01 | The entire doorset shall be shipped to job site ready to install and operate.Hinges -Shall be by IAC, CAM lift design, painted to match the door.Preparation- Door leaf and frame shall be predrilled and tapped in accordance with manufacturer’s templates to accept specified hardware.Vision Panel (if applicable)- Double glazed window unit comprising two panes of laminated safety glass (Thickness dependant on vision panel size) sealed within 2mm steel frames to suit leaf thickness of 64mm. Acoustic absorptive material fitted between the panes. Steel frames to be RAL polyester powder coated to match the door finish.Colour / Finishes- Leaf and frame to be polyester powder coated to standard RAL colours. | BI01010001010000000000000515BI0100001376 | ||
| 264 | 35.02 | LVL +150 | BI01010001010000000000000515BI0100001377 | 12 | SQM |
| 265 | 35.03 | LVL +3150 | BI01010001010000000000000515BI0100001378 | 24.96 | SQM |
| 266 | 35.04 | LVL +7050 | BI01010001010000000000000515BI0100001379 | 8.64 | SQM |
| 267 | 35.05 | LVL +10050 | BI01010001010000000000000515BI0100001380 | 8.64 | SQM |
| 268 | 35.06 | LVL +14850 | BI01010001010000000000000515BI0100001381 | 8.64 | SQM |
| 269 | 36 | Providing and fixing factory made uPVC white colour (FINESTA/ /KOMMERLING/ENCRAFT /equivalent)sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (including 5 mm thick plain Glass) Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) complete excluding GST. | BI01010001010000000000000515BI0100001383 | ||
| 270 | 36.01 | Auditorium | BI01010001010000000000000515BI0100001384 | ||
| 271 | 36.02 | LVL +150 | BI01010001010000000000000515BI0100001385 | 7.07 | SQM |
| 272 | 36.03 | LVL +3150 | BI01010001010000000000000515BI0100001386 | 2.25 | SQM |
| 273 | 36.04 | LVL +7050 | BI01010001010000000000000515BI0100001387 | 2.25 | SQM |
| 274 | 36.05 | LVL +10050 | BI01010001010000000000000515BI0100001388 | 2.25 | SQM |
| 275 | 36.06 | Gate Complex | BI01010001010000000000000515BI0100001389 | 15 | SQM |
| 276 | 37 | ACOUSTIC WALL PANELING: M/F Suspended ceiling, which includes Gypsteel ULTRA ™ CRP surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending Gypsteel ULTRA™ CRP surface ribbed intermediate channels of size 45mm (with two flanges of 15mm each) from the soffit at 1220mm centres with Gypsteel ULTRA™ CRP surface ribbed ceiling angle of width 25mmx10mm fixed to soffit with GI cleat and steel expansion fasteners(Mfg by Saint Gobain Gyproc). Then Gypsteel ULTRA™ CRP surface ribbed Ceiling section of having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the Gypsteel ULTRA™ intermediate channel with the help of connecting clip and in direction perpendicular to the Gypsteel intermediate™ channel at 297.5mm centres. Single layer of 595x595x12.5mm tapered edge Fultone tile is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. | BI01010001010000000000000515BI0100001390 | ||
| 277 | 37.01 | Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally square edges of the tile are to be jointed and finished with three layer so as to have a flush look which includes filling and finishing with Gyproc Jointing compound, Gyproc Joint Paper tape and two coats of Drywall Top Coat (as per recommended practices of Saint-Gobain Gyproc India). 50mm glass wool of density 32kg/m³ placed over the Fulton etc. complete in all respect excluding GST as directed by Engineer-in-charge.. | BI01010001010000000000000515BI0100001391 | ||
| 278 | 37.02 | LVL +150 | BI01010001010000000000000515BI0100001392 | 746.9 | SQM |
| 279 | 37.03 | AT ALL LEVEL | BI01010001010000000000000515BI0100001393 | 2309.9 | SQM |
| 280 | 38 | ACOUSTIC FALSE CELLING: M/F Suspended ceiling, which includes Gypsteel ULTRA ™ CRP surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending Gypsteel ULTRA™ CRP surface ribbed intermediate channels of size 45mm (with two flanges of 15mm each) from the soffit at 1220mm centres with Gypsteel ULTRA™ CRP surface ribbed ceiling angle of width 25mmx10mm fixed to soffit with GI cleat and steel expansion fasteners(Mfg by Saint Gobain Gyproc). Then Gypsteel ULTRA™ CRP surface ribbed Ceiling section of having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the Gypsteel ULTRA™ intermediate channel with the help of connecting clip and in direction perpendicular to the Gypsteel intermediate™ channel at 297.5mm centres. Single layer of 595x595x12.5mm tapered edge Fultone tile is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. | BI01010001010000000000000515BI0100001394 | ||
| 281 | 38.01 | Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally square edges of the tile are to be jointed and finished with three layer so as to have a flush look which includes filling and finishing with Gyproc Jointing compound, Gyproc Joint Paper tape and two coats of Drywall Top Coat (as per recommended practices of Saint-Gobain Gyproc India). 50mm glass wool of density 32kg/m³ placed over the Fulton etc. complete in all respect excluding GST as directed by Engineer-in-charge.. | BI01010001010000000000000515BI0100001395 | ||
| 282 | 38.02 | LVL +150 | BI01010001010000000000000515BI0100001396 | 382 | SQM |
| 283 | 38.03 | LVL +14850 | BI01010001010000000000000515BI0100001397 | 1330 | SQM |
| 284 | 39 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x3000 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5nn dia and 50mm long dash fasteners, 4mm GI adjustable road with galvanised butterfly level clips of size 85X30X0.8mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyster paint, all complete for all heights as per specifications, drawings and as directed by Engineers-in-charge. | BI01010001010000000000000515BI0100001399 | ||
| 285 | 39.01 | GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. \n | BI01010001010000000000000515BI0100001400 | ||
| 286 | 39.02 | LVL +3150 | BI01010001010000000000000515BI0100001401 | 221.38 | SQM |
| 287 | 40 | Providing and applying Xypex or equivalent crystalline product/Concentrate , as waterproofing coating & durability enhancement by crystallization to be supported by at least two national / international test reports showing clear scanning electron microscopic (SEM) photographs of dansified and mature crystals formation to plug all the capillary tracks and pores of the concrete permanently and permeability tested as per IS-2720 conducted by CBRI the concrete should not absorbed water more than 1.5 gms and not more than 1mm from the concrete surface. The product to be listed in ICC-ES evaluation report index January 2009, 2010 and 2011. The treatment to be carried out on the cleaned concrete surface as per manufacturer’s specification/data sheet. The application to be carried out with brush in one coat @0.80 Kg/Coat by using all safety equipments and necessary arrangements of scaffolding to reach the required heightcomplete in all respect excluding GST as per specification as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001402 | ||
| 288 | 40.01 | WATER TANK,SUNKEN PORTION IN ALL FLOORS & DUCT | BI01010001010000000000000515BI0100001403 | ||
| 289 | 40.02 | WATER TANK (L.FL.) | BI01010001010000000000000515BI0100001404 | 256.83 | SQM |
| 290 | 40.03 | LVL +3150 | BI01010001010000000000000515BI0100001405 | 156.88 | SQM |
| 291 | 40.04 | LVL +7050 | BI01010001010000000000000515BI0100001406 | 159.8 | SQM |
| 292 | 40.05 | LVL +10050 | BI01010001010000000000000515BI0100001407 | 159.8 | SQM |
| 293 | 40.06 | DOOR FRAME HOLD FAST | BI01010001010000000000000515BI0100001408 | ||
| 294 | 41 | Providing Hilti hold fast of 150 mm length ,10 mm dia including fixing to frame with 10 mm diameter bolts, nuts and as directed by Engineer -In-Charge including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work complete in all respect excluding GST. | BI01010001010000000000000515BI0100001409 | ||
| 295 | 41.01 | Auditorium | BI01010001010000000000000515BI0100001410 | ||
| 296 | 41.02 | LVL +150 | BI01010001010000000000000515BI0100001411 | 376 | NOS |
| 297 | 41.03 | LVL +3150 | BI01010001010000000000000515BI0100001412 | 134 | NOS |
| 298 | 41.04 | LVL +7050 | BI01010001010000000000000515BI0100001413 | 168 | NOS |
| 299 | 41.05 | LVL +10050 | BI01010001010000000000000515BI0100001414 | 168 | NOS |
| 300 | 41.06 | LVL +14850 | BI01010001010000000000000515BI0100001415 | 24 | NOS |
| 301 | 41.07 | Gate Complex | BI01010001010000000000000515BI0100001416 | 12 | NOS |
| 302 | 42 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for door, with necessary screws etc. complete in all respect excluding GST as directed by Engineer-in-charge. (Make Godrej )Daina - 8170 | BI01010001010000000000000515BI0100001417 | ||
| 303 | 42.01 | Auditorium | BI01010001010000000000000515BI0100001418 | ||
| 304 | 42.02 | LVL +150 | BI01010001010000000000000515BI0100001419 | 40 | NOS |
| 305 | 42.03 | LVL +3150 | BI01010001010000000000000515BI0100001420 | 9 | NOS |
| 306 | 42.04 | LVL +7050 | BI01010001010000000000000515BI0100001421 | 12 | NOS |
| 307 | 42.05 | LVL +10050 | BI01010001010000000000000515BI0100001422 | 12 | NOS |
| 308 | 42.06 | Gate Complex | BI01010001010000000000000515BI0100001423 | 2 | NOS |
| 309 | 43 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :and as directed by Engineer -in-charge.including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work complete in all respect excluding GST as directed by Engineer-in-charge.. | BI01010001010000000000000515BI0100001424 | ||
| 310 | 43.01 | Auditorium | BI01010001010000000000000515BI0100001425 | ||
| 311 | 43.02 | LVL +150 | BI01010001010000000000000515BI0100001426 | 40 | NOS |
| 312 | 43.03 | LVL +3150 | BI01010001010000000000000515BI0100001427 | 9 | NOS |
| 313 | 43.04 | LVL +7050 | BI01010001010000000000000515BI0100001428 | 14 | NOS |
| 314 | 43.05 | LVL +10050 | BI01010001010000000000000515BI0100001429 | 14 | NOS |
| 315 | 43.06 | Gate Complex | BI01010001010000000000000515BI0100001430 | 2 | NOS |
| 316 | 44 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, with double speed adjustment with necessary accessories and screws etc. required for the work including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work complete in all respect excluding GST as directed by Engineer-in-charge. Godrej Door Closer 80-120kgs ,Product code-5750, UNSPSC Code30171514SD00170 | BI01010001010000000000000515BI0100001431 | ||
| 317 | 44.01 | Auditorium | BI01010001010000000000000515BI0100001432 | ||
| 318 | 44.02 | LVL +150 | BI01010001010000000000000515BI0100001433 | 29 | NOS |
| 319 | 44.03 | LVL +3150 | BI01010001010000000000000515BI0100001434 | 14 | NOS |
| 320 | 44.04 | LVL +7050 | BI01010001010000000000000515BI0100001435 | 14 | NOS |
| 321 | 44.05 | LVL +10050 | BI01010001010000000000000515BI0100001436 | 14 | NOS |
| 322 | 44.06 | LVL +14850 | BI01010001010000000000000515BI0100001437 | 4 | NOS |
| 323 | 44.07 | Gate Complex | BI01010001010000000000000515BI0100001438 | 1 | NOS |
| 324 | 45 | Providing and fixing door stopper cost of fitting and fixtures required for the work, mending the damages of floor including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work complete in all respect excluding GST as directed by Engineer-in-charge.Make-Suzu, Code-HW053 | BI01010001010000000000000515BI0100001439 | ||
| 325 | 45.01 | Auditorium | BI01010001010000000000000515BI0100001440 | ||
| 326 | 45.02 | LVL +150 | BI01010001010000000000000515BI0100001441 | 29 | NOS |
| 327 | 45.03 | LVL +3150 | BI01010001010000000000000515BI0100001442 | 14 | NOS |
| 328 | 45.04 | LVL +7050 | BI01010001010000000000000515BI0100001443 | 14 | NOS |
| 329 | 45.05 | LVL +10050 | BI01010001010000000000000515BI0100001444 | 14 | NOS |
| 330 | 45.06 | LVL +14850 | BI01010001010000000000000515BI0100001445 | 4 | NOS |
| 331 | 45.07 | Gate Complex | BI01010001010000000000000515BI0100001446 | 1 | NOS |
| 332 | 46 | Providing & filling sunken floors with broken A.A.C block well compacted and top surface dressed and levelled to proper gradient as per direction including hoisting, lowering, laying and compacting, watering , including cost conveyance, royalities of all material, cost of all labour for loading and unloading, T & P etc sundries required for the work etc complete excluding GST as directed by the Engineer-in-Charge | BI01010001010000000000000515BI0100001447 | ||
| 333 | 46.01 | LVL +3150 | BI01010001010000000000000515BI0100001448 | 10.64 | CUM |
| 334 | 46.02 | LVL +7050 | BI01010001010000000000000515BI0100001449 | 10.64 | CUM |
| 335 | 46.03 | LVL +10050 | BI01010001010000000000000515BI0100001450 | 10.64 | CUM |
| 336 | 47 | STRUCTURAL GLAZING: Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing(with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: | BI01010001010000000000000515BI0100001451 | ||
| 337 | 47.01 | Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III(the ststem must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminimum sections for fixing glazing panels of various thickness, aluminimum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop(barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire harzard including: | BI01010001010000000000000515BI0100001452 | ||
| 338 | 47.02 | Fabricating and supplying serrated M.S. hot dip galvanised/Aluminimum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/Masonary/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contracts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. | BI01010001010000000000000515BI0100001453 | ||
| 339 | 47.03 | Providing and filling two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory/workshop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. | BI01010001010000000000000515BI0100001454 | ||
| 340 | 47.04 | Providing and fixing in position flashing of solid aluminimum sheet 1mm thick and of sizes, shapes and profiles, as requirede as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. | BI01010001010000000000000515BI0100001455 | ||
| 341 | 47.05 | Making provision for drainage of moisture/water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom(if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of glazed units , T&P , scaffolding and other incidental charges including wastages etc. , enabling temporary structures and services , cranes or cradles etc. as describe above and as specified. The item includes the cost of getting all the structural and functional design include shop drawings checked by a structural designer , dully approved by Engineer-in-charge. The item also includes the cost of all mocks ups at site, cost of all samples of the individual components for testing in an approved laboratory , field tests on the assembled working structural glazing as specified , cleaning and protection till the handling over the building for occupation. In the end ,the Contractor shall provide a water tight structural glazing as specified , cleaning and protection till the handiling over the of building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. complete as required ,as per Architectural drawings, as per item description , as specified as per the approved shop drawing and as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001456 | ||
| 342 | 47.06 | The cost of providing extruded aluminium frames , shadow boxes , extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However ,for the purpos e of payment ,only the actual area of structural glazing (including width of grooves) on external face shall be measured in sqm. up to two decimal places. | BI01010001010000000000000515BI0100001457 | ||
| 343 | 47.07 | Following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 sqm from the certified laboratories accreditation Board for Testing and Calibration Laboratories),Department of Science & Technologies , India. Cost of testing is payble separately . The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of test and importance of the work . Performance Testing of structural glazing system tests to be conducted in the NBL Certified laboratories | BI01010001010000000000000515BI0100001458 | ||
| 344 | 47.08 | 1.Performance Laboratory test for air leakage Test (-50pa to -300pa ) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr\". | BI01010001010000000000000515BI0100001459 | ||
| 345 | 47.09 | 2.Static Water penetration Test. (50pa to 1500pa) as per ASTME-331-09 testing method for a range upto 2000 ml.\" | BI01010001010000000000000515BI0100001460 | ||
| 346 | 47.1 | 3.Dynamic Water Penetration (50pa to 1500pa)as per AAMA 501.01-05 testing method for a range upto 2000ml\" | BI01010001010000000000000515BI0100001461 | ||
| 347 | 47.11 | 4.Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50mm\". | BI01010001010000000000000515BI0100001462 | ||
| 348 | 47.12 | 5.Seismic Movement Test (upto 30mm) as per AAMA 501.4-09 testing method for qualitative test\"Tests to be conducted on site. | BI01010001010000000000000515BI0100001463 | ||
| 349 | 47.13 | 6.Onsite Test for Water Leakage for a pressure range 50kpa to 240 kpa (35psi) upto 2000ml\". | BI01010001010000000000000515BI0100001464 | ||
| 350 | 47.14 | The item of work inclusive of cost and conveyance of all materials, fittings, fixtures, cost of all labour, taxes, sundries, T&P, scaffolding/staging required for the work all complete as per the direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001465 | ||
| 351 | 47.15 | AT ALL LEVELS | BI01010001010000000000000515BI0100001466 | 4638.6 | SQM |
| 352 | 48 | Providing & supplying Glass Panel comprising of 6mm thick heat strengthened soft coated reflective glass of approved colour and shade with reflective soft coating on surface #2 of approved colour and shade etc,all complete for the required performances as specified , as per the architectural drawing , as per the approved shop drawings, as specified, and as directed by the engineer - in - charge. For payment , only the actual area of glass on face #1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of glass panels in the curtain glazing is included in cost of relevent item*) | BI01010001010000000000000515BI0100001467 | ||
| 353 | 48.01 | (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of Saint - Gobain make having properties as visible Light transmittance (VLT) of 40to 45 %, Light reflection internal 10 to 15%, light reflection external 10 to 15 %, shading coefficient (0.25-0.29) and U value of 1.6 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. | BI01010001010000000000000515BI0100001468 | ||
| 354 | 48.02 | The item of work inclusive of cost and conveyance of all materials, fittings, fixtures, cost of all labour, sundries, T&P, scaffolding/staging required for the work all complete as per the direction of Engineer-in-charge.In all Floors | BI01010001010000000000000515BI0100001469 | ||
| 355 | 48.03 | AT ALL LEVELS | BI01010001010000000000000515BI0100001470 | 4638.6 | SQM |
| 356 | 49 | Design, Supplying and Installation of glass canopy made of 13.52mm thick Laminated and toughened glass in front of the main entrance of the building as designated in the drawing submitted. The installation shall be done along with the accessories like MS bush of 50mm dia solid cylinders, properly welded to the main MS structure.The bushes shall be prepared with threaded hole to accommodate the SS 304 grade Fixed head or articulated Bolts of M12, fixing the Stainless steel Spider fittings Dorma RSF or Kinlong or Equivalent to the main MS structure. The Glass canopy shall be held in position with SS Fixed Head Bolts from RSF Dorma or Kinlong or Equivalent. The gradient as described in the drawing shall be maintained with the help of flat SS washers. The joints shall be sealed with clear weathering silicones of Dow Corning or equivalent. | BI01010001010000000000000515BI0100001471 | ||
| 357 | 49.01 | LVL +3150 | BI01010001010000000000000515BI0100001472 | ||
| 358 | 49.02 | Canopy system As per Manufacturer with necessary accessories, fittings, Bushes, SS Bolts and Labour charges. | BI01010001010000000000000515BI0100001473 | 525 | SQM |
| 359 | 49.03 | Extra for 13.52mm thick (6mm Clear+1.52mm PVB+6mm clear) laminated and toughened glass, with Silicones, necessary holes, cuttings etc. | BI01010001010000000000000515BI0100001474 | 525 | SQM |
| 360 | 50 | TRUSS FOR GLASS CANOPY:Extra for Designing, Providing and Fixing MS Tube of Approved size by welding etc, for substructure for Glass Canopy Panels, Screens etc., including applying a priming coat of approved steel primer, fixed with dash fasteners, complete inclusive of cost and conveyance of all materials, fittings, fixtures, cost of all labor, sundries, T&P Scaffolding/staging required for the work all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001475 | ||
| 361 | 50.01 | LVL +3150 | BI01010001010000000000000515BI0100001476 | 26250 | KG |
| 362 | 51 | Supply and fixing STRAIGHT / curved sheets as required “SELF SUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9 mm THICK AA 3004 ALUMINIUM ALLOY. The general roof-construction shall comprise from bottom to top: \n1.First Layer - Steel Deck liner – Solid 28- 35 /200 Galvanised steel deck liner (GSM 275) 550 MPa, 0.5 mm TCT 1000 -1050 mm total cover width28- 35mm deep ribs spanning up to 1300 mm centres (multiple spans). The finish to the exposed surface of the liner will be polyester coating with film thickness of 23µm +/- 2 µm. only. Where false ceiling is not provided the Liner shall be perforated and the Liner thickness will be 0.7mm The perforation shall be 23% with non-woven acoustic paper to enhance acoustic properties . \n2. Second Layer - Vapour Control Layer –– – A single layer VCL, Polyethylene based vapor control membrane, reinforced with mono filament scrim to provide tensile strength. VCL weight 250 GSM, with Water Vapor permeability less than 0.39 grams / m2/ day. \n3. Third Layer - Insulation – One layer of Rockwool insulation of 125 mm thickness , in 75 and 50 mm each minimum 60 kg/m³ density with thermal conductivity of K=0.038 W/mk at 20 degrees Celsius when tested to ASTM C518. Make Rockwool India / Roxul Make . The build up system shall achieve a U value of 0.36 W/ m2 K, considering Thermal losses through clips .\n | BI01010001010000000000000515BI0100001477 | ||
| 363 | 51.01 | 4. Fourth Layer - ST Clip – Aluminium clips ST clips – in grade 6061, of suitable height with thermal barrier pads to be fixed to the sub purlins with SS 304 screws Sub girt Top Hat and top hat bracket as required -1.6 mm thick and 2mm thick Galvanised steel hat section to support for curved roofs \n5.Fifth Layer - Top layer – Aluminium 65/400 Straight / curved profile sheeting manufactured from aluminium self supported standing seam roof system from aluminium alloy AA 3004 H46 (AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9mm and PVDF2 finish ( standard colours ) with on the exposed surface. PVDF2 finish coated from approved paint suppliers PPG/BECKER / AKZONOBEL / VALSPAR . The external PVDF2 coating shall be of 23-25 microns thickness and shall have protective guard film of 75micron to prevent scratches during roll forming & handling Accessories Including ridge gable and eaves, Fasteners\n The material properties shall be as follows:\nUltimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, \nSheets are to be laid to meet the requirements of the\nbuilding geometry and fixed on Aluminum clips. Clip to be fixed to the purlins with SS 304 screws, with a minimum dia of 5.5 mm\nCertificates - The roofing system shall be certified with a \n1- British Board of Agreement Certificate \n2- the Institute of Bautechnic Zulassungbeschield N R -14.1 .181 All installation is to be carried out by approved trained roofing installer.\n3- FM certificate in India and the roofing system should have passed FM test of Class 1- 105\n\nPerformance parameters . \n1- Wind Load to be considered as per IS 875 – Part 3 \n2- Acoustics – STC test to achieve 39 dB, with a negative tolerance of -2dB \n3- U value – 0.36 W/m2 K considering thermal bridging losses\n_Purlin spacing to be as the wind load requirement and 1300 mm \nThe installation team shall be fully trained and approved by the manufacturer, and Approved Installers and shall provide the letter from manufacturer \n | BI01010001010000000000000515BI0100001478 | ||
| 364 | 51.02 | Performance parameters . \n1- Wind Load to be considered as per IS 875 – Part 3 \n2- Acoustics – STC test to achieve 39 dB, with a negative tolerance of -2dB \n3- U value – 0.36 W/m2 K considering thermal bridging losses\n_Purlin spacing to be as the wind load requirement and 1300 mm \nThe installation team shall be fully trained and approved by the manufacturer, and Approved Installers and shall provide the letter from manufacturer \n | |||
| 365 | 51.03 | LVL +14850 | BI01010001010000000000000515BI0100001479 | 4202 | SQM |
| 366 | 52 | Flashings manufactured from aluminium alloy AA 3004 (AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF finish on the exposed surface. The material shall be of the same colour. including all formations as per the directions of Engineer In Charge. | BI01010001010000000000000515BI0100001480 | ||
| 367 | 52.01 | LVL +14850 | BI01010001010000000000000515BI0100001481 | 141 | SQM |
| 368 | 53 | TRUSS: Design, supply, fabrication, assembling and\nerection of structural steel roof to metal sheeting in desired profile as per architectural concept design. The Agency must have their own design team and own factory facility and shall share the entire structural design analysis report. Design & shop drawings shall be provided by agency to Engineer-in-charge/ architect for approval prior to commencement of work. Measurement shall be on surface area of roof canopy as shown in tender drawings. Support steel structure for columns, vertical supports, beams, horizontal members etc. as per drawing, consisting of MS built-up sections, pipes, hollow sections, etc. made from grade structural steel, conforming to IS 1161/4923 and IS 2062. SAW/MMAW/MIG welding process shall be used for structural steel fabrication. Work includes transportation, cutting, threading, machining, leads and lifts upto all heights, tools and plants and necessary scaffolding etc. required for all operations involved to make structure functional.\n | BI01010001010000000000000515BI0100001482 | ||
| 369 | 53.01 | Rate shall include supply, preparation and\napplication of anti-corrosive surface coating as per specification below: Steel surface shall be cleaned and prepared by Primer: Epoxy primer in two coats Polyurethane: shall be applied two coats over primer of ICI or BERGER Make. All coats shall be applied by spray painting at the fabrication yard. Touch-up coat shall be applied on all damaged portions of coating, using b est practices, after erection of the structure. The steel structure shall be designed as per the following standards:\nIS 875 for wind load IS: 875 Part – I , II & III – 1987 for primary loads and their combinations\nIS: 800, 1984 & IS: 806, 1968 for stability and\ncritical stresses IS: 7215 for fabrication tolerances IS: 816, 1969 for welded structural joints IS: 814 (Part – I & II), 1974 for electrodes for welding IS: 1367 (Part – III) 1991 & IS: 3757, 1985 for bolted structural joints | BI01010001010000000000000515BI0100001483 | ||
| 370 | 53.02 | LVL +10350 FOR ROOFING | BI01010001010000000000000515BI0100001484 | 275000 | KG |
| 371 | 54 | Providing and fixing anodized aluminium louvers (anodized transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with minimum anodic coating of grade AC 15 with approved standard aluminium section fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper shape and size to window opening and fixing the same in position including cost, conveyance, loading, unloading of all materials, cost of all labour, sundries and T&P, scaffolding if required etc complete as per the direction of Engineer Engineer-in-charge. (Samples of aluminium section is to be approved before use for work and weight of grill to be measured for payment.) | BI01010001010000000000000515BI0100001485 | ||
| 372 | 54.01 | LVL +3150 | BI01010001010000000000000515BI0100001486 | 142.4 | KG |
| 373 | 55 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin-charge). | BI01010001010000000000000515BI0100001487 | 21.75 | CUM |
| 374 | 56 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001488 | 2900 | SQM |
| 375 | 57 | P.H WORKS | BI01010001010000000000000515BI0100001489 | ||
| 376 | 58 | P.H INTERNAL | BI01010001010000000000000515BI0100001490 | ||
| 377 | 59 | Providing all materials, labour, T&P for laying of following dia CPVC pipes S.D.R - 11 as per IS-15778 with ISI mark including fixing of required size CPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screw etc. including testing the joints with required water presure.The cost inclusive of all taxes,duties,transportation scaffolding etc. as per specification and direction of Engineer-in-charge.\nMake : Ashirvad/SUPREME/Astral | BI01010001010000000000000515BI0100001491 | ||
| 378 | 59.01 | 20mm nominal bore dia | BI01010001010000000000000515BI0100001492 | 455 | Mtr |
| 379 | 59.02 | 25mm nominal bore dia | BI01010001010000000000000515BI0100001493 | 679 | Mtr |
| 380 | 59.03 | 32mm nominal bore dia | BI01010001010000000000000515BI0100001494 | 312 | Mtr |
| 381 | 59.04 | 40mm nominal bore dia | BI01010001010000000000000515BI0100001495 | 16 | Mtr |
| 382 | 59.05 | 50mm nominal bore dia | BI01010001010000000000000515BI0100001496 | 118 | Mtr |
| 383 | 59.06 | 65mm nominal bore dia | BI01010001010000000000000515BI0100001497 | 237 | Mtr |
| 384 | 59.07 | 80mm nominal bore dia | BI01010001010000000000000515BI0100001498 | 11 | Mtr |
| 385 | 59.08 | 100mm nominal bore dia | BI01010001010000000000000515BI0100001499 | 237 | Mtr |
| 386 | 60 | Supplying, installing and testing approved make brass ball valves conforming to IS 1703 with unions etc., complete. as per direction of Engineer-in-Charge. The cost inclusive of all taxes, duties, transportation, scaffolding etc. all complete as per specification & direction of EIC. (Make- Zoloto/ASHIRVAD/Astral | BI01010001010000000000000515BI0100001500 | ||
| 387 | 60.01 | 40mm dia brass ball valve | BI01010001010000000000000515BI0100001501 | 4 | No |
| 388 | 60.02 | 32mm dia brass ball valve | BI01010001010000000000000515BI0100001502 | 4 | No |
| 389 | 60.03 | 25mm dia brass ball valve | BI01010001010000000000000515BI0100001503 | 5 | No |
| 390 | 60.04 | 20mm dia brass ball valve | BI01010001010000000000000515BI0100001504 | 2 | No |
| 391 | 61 | Supplying, installing, testing and commissioning butterfly valves with standard lever confirming to IS 13039 with necessary connecting fittings like flanges ,nuts and bolts etc., complete As per direction of Engineer-in-Charge. including testing the joints with required water pressure. The cost inclusive of all taxes, duties, transportation, scaffolding etc. all complete as per specification & direction of EIC. (Make- Zoloto/ASHIRVAD/Astral) | BI01010001010000000000000515BI0100001505 | ||
| 392 | 61.01 | 50mm dia | BI01010001010000000000000515BI0100001506 | 4 | No |
| 393 | 61.02 | 65mm dia | BI01010001010000000000000515BI0100001507 | 2 | No |
| 394 | 61.03 | 80mm dia | BI01010001010000000000000515BI0100001508 | 2 | No |
| 395 | 61.04 | 100mm dia | BI01010001010000000000000515BI0100001509 | 2 | No |
| 396 | 62 | Supplying, installing, testing and commissioning approved make water level indicator for the Underground Sump and OHT . The quoted rate shall include for necessary wiring in PVC conduit between the control panel, underground sump and overhead tank.(length of cable approx. 100 mts.)The cost inclusive of all taxes, duties, transportation, scaffolding etc. all complete as per specification & direction of EIC. | BI01010001010000000000000515BI0100001510 | 6 | No |
| 397 | 63 | Providing ,fixing , testing and commissioning of Compact Self Contained Skid Mounted In-Line, Multistage, centrifugal Hydro pneumaticpumps of 3 nos.(2 Working + 1 Stand by) and water Flow Rate of each pump at 5 Lps and Head of 35 MWC withg suitable KW with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor with mechanical seal. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head.Non metallic (SS-304) suction and delivery header shall be painted with Synthetic enamel painted over a coat of primer. Vendor shall also consider Precharged diaphragm pressure vessel capacity 300 lit with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. The quoted rate also inclusive of pressure gauge, pressure switches, pressure transducers,solinoid vale at terrace floor level, inter connecting power and control cabling etc. complete.RCC foundation and Foundation bolts ,MS base frame and suitable size of isolation valves & Y type strainer with SS mesh/foot valve at suction side and isolation valve and NRV at the delivery side of the pumps as per the manufactures recommendations.- Flushing | BI01010001010000000000000515BI0100001511 | ||
| 398 | 63.01 | Vendor shall aslo consider control panel for Hydro pneumatic pumps shall be mounted on Pedestal of 300 mm height or wall mounted microprocessor PID controller and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS 485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. The electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring & End terminations , earth strip of GI 25 x 3 mm,cable tray and any other necessary imports etc.Make : Kirloskar | BI01010001010000000000000515BI0100001512 | 1 | Set |
| 399 | 64 | Providing ,fixing , testing and commissioning of Compact Self Contained Skid Mounted In-Line, Multistage, centrifugal Hydro pneumaticpumps of 3 nos.(1 Working + 1 Stand by) and water Flow Rate of each pump at 2.5 Lps and Head of 35 MWC withg suitable KW with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor with mechanical seal. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head.Non metallic (SS-304) suction and delivery header shall be painted with Synthetic enamel painted over a coat of primer. Vendor shall also consider Precharged diaphragm pressure vessel capacity 300 lit with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. The quoted rate also inclusive of pressure gauge, pressure switches, pressure transducers,solinoid vale at terrace floor level, inter connecting power and control cabling etc. complete.RCC foundation and Foundation bolts ,MS base frame and suitable size of isolation valves & Y type strainer with SS mesh/foot valve at suction side and isolation valve and NRV at the delivery side of the pumps as per the manufactures recommendations.- Domestic | BI01010001010000000000000515BI0100001513 | ||
| 400 | 64.01 | Vendor shall aslo consider control panel for Hydro pneumatic pumps shall be mounted on Pedestal of 300 mm height or wall mounted microprocessor PID controller and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS 485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. The electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring & End terminations , earth strip of GI 25 x 3 mm,cable tray and any other necessary imports etc.Make : Kirloskar | BI01010001010000000000000515BI0100001514 | 1 | Set |
| 401 | 65 | Providing ,fixing , testing and commissioning of submersible type storm Water lift pumps set 2 no’s (1 Working + 1 Standby) of Water Flow Rate of each pump 10 cum/hr with the head of 15 MWC adequate the casing shall be cast iron and impeller shall be Stainless steel the pump HP capacity shall be provided by manufacturer at suitable head to work on 3Ph, 50Hz, 400/440V with necessary unions, flanges, foundation bolts, RCC footing in 1:2:4 etc. complete. Vendor shall consider the electrical control panel comprising of all accessories such as MCB , pressure switches, pressure transducers, control wiring & End terminations , earth strip of GI 25 x 3 mm,cable tray and suitable size of and isolation valve and NRV at the delivery side of the pumps as per the manufactures recommendation and any other necessary imports etc. complete. Make : Kirloskar | BI01010001010000000000000515BI0100001515 | 3 | Set |
| 402 | 66 | Supplying, fixing and testing Puddle flanges for inlet, outlet, vent and overflow pipes, fittings with D.I frame and cover to overhead water tank and under ground water tank complete with steps as shown on the drawings etc., complete. | BI01010001010000000000000515BI0100001516 | 1 | job |
| 403 | 66.01 | a) UNDER GROUND WATER TANK | BI01010001010000000000000515BI0100001517 | ||
| 404 | 66.02 | i) 6 nos. DI manhole frame and cover (heavy duty) | BI01010001010000000000000515BI0100001518 | ||
| 405 | 66.03 | (weight=400 KN.) with locking facility | BI01010001010000000000000515BI0100001519 | ||
| 406 | 66.04 | (ii)150mm dia = 1 nos (iii)100 mm dia =8 nos | BI01010001010000000000000515BI0100001520 | ||
| 407 | 66.05 | (iv) 50 mm dia =9 nos (v) 250mm dia = 1 no (viii) 200mm dia = 1 no. | BI01010001010000000000000515BI0100001521 | ||
| 408 | 66.06 | vi)6 nos. step ladder (Aluminium ladder) (vii) 80mm dia = 1nos viii)32mm dia -1 no | BI01010001010000000000000515BI0100001522 | ||
| 409 | 66.07 | b) OVER HEAD WATER TANK | BI01010001010000000000000515BI0100001523 | ||
| 410 | 66.08 | i) 10 nos. DI manhole frame and cover (medium duty) | BI01010001010000000000000515BI0100001524 | ||
| 411 | 66.09 | (weight=15 KN.) with locking facility | BI01010001010000000000000515BI0100001525 | ||
| 412 | 66.1 | (ii)50 mm dia = 7 nos (iii)80 mm dia = 1nos (iv) 40mm dia =3 no.V)100mm dia = 7 no vi)32 dia = 4 vii) 150mm dia=2 | BI01010001010000000000000515BI0100001526 | ||
| 413 | 66.11 | vii) 10 nos. step ladder (Aluminium ladder) | BI01010001010000000000000515BI0100001527 | ||
| 414 | 66.12 | Paddle flanges , lader , manhole cover | BI01010001010000000000000515BI0100001528 | ||
| 415 | 67 | Supplying, installing, testing and commissioning approved make pressure float valve of 50 mm dia for OHT . The quoted rate shall include for necessary fittings etc .as per direction of Engineer-in-Charge. including testing the joints with required water pressure. The cost inclusive of all taxes, duties, transportation, scaffolding etc. all complete as per specification & direction of EIC. (Make- Beekey) | BI01010001010000000000000515BI0100001529 | 4 | Set |
| 416 | 68 | Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of materials , curing, conveyance, taxes of all materials etc. all complete as per specification & direction of EIC. | BI01010001010000000000000515BI0100001530 | 500 | Mtr |
| 417 | 69 | Providing all labour ,T&P for cutting holes in bricks or stone masonry wall for taking pipes and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4 to original shape including cost of all materials, curing, conveyance, taxes, duties etc. all complete as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001531 | ||
| 418 | 69.01 | For 15mm to 50mm dia pipe to pass in 125mm to 250mm thick wall | BI01010001010000000000000515BI0100001532 | 20 | NO |
| 419 | 69.02 | 250mm to 375mm thick wall | BI01010001010000000000000515BI0100001533 | 20 | No |
| 420 | 70 | Providing all labour ,T&P for cutting holes in R.C.C floors and roofs for passing G.I / P.V.C pipes and fittings etc and repairing the holes after inspection of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof. including cost of all materials, curing, conveyance, taxes, duties etc. all complete as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001534 | 100 | No |
| 421 | 71 | Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china water closet (Europian Water Closet (EWC) SET wall hung . with solid seat cover & Cistern with Lid of standard quality approved make including supply of sutaible for EWC bolt & clamp including cost of all taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make Jaquar (Model no-SNR-CHR-51097) | BI01010001010000000000000515BI0100001535 | ||
| 422 | 71.01 | Wall hung european water closet | BI01010001010000000000000515BI0100001536 | 76 | nos. |
| 423 | 72 | Supplying, installing, testing and commissioning of approved make White Viterous urinals 3.8 LPM supported by CI/MS bracket duly painted, including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges, automatic flushing systems for urinal to ensure flusing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells (Sensor), eyes electrically operated solenoid valve, gate valve, black box and necessary wiring in conduit from solenoid value to black box and to mains etc, complete. Including necessary wall cutting/chasing and making good, as requiredall complete as per specification & direction of the Engineer-in-charge.(Make:jaquar Model No- URS-WHT-132530) | BI01010001010000000000000515BI0100001537 | 52 | Set |
| 424 | 73 | Providing all materials and labour for fitting and fixing of following size white glazed vitreous china wash hand basin of approved make with supply & fixing of basin bolts & screw,32mm PVC waste pipe of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. with all taxes, duties, transportation etc. all complete as per direction of EIC.Make:Jaquar (Model no-CNS-WHT-801) | BI01010001010000000000000515BI0100001538 | ||
| 425 | 73.01 | Wash Hand Basin of size 550x410mm) | BI01010001010000000000000515BI0100001539 | 89 | Set |
| 426 | 74 | Providing all materials , labour ,T&P for fitting & fixing of following size of Stain less steel kitchen sink with drain board fixed on M.S bracket made out of 40x40x6mm size MS angle fixing the wall and making good the dameges, including coupling strainer & PVC. Waste pipe etc. Painting the bracket with Anticorrosive paint etc. including Testing all complete as per specification and direction of the Engineer-in-charge.(Make- Nirali Popular Range ) | BI01010001010000000000000515BI0100001540 | ||
| 427 | 74.01 | Stainless steel kitchen sink with drain board of overal size-1040x510mm & Bowl size-460x410x200mm. Make-NIRALI (Elegance) of popular range, Satin Finish | BI01010001010000000000000515BI0100001541 | 1 | No |
| 428 | 75 | Providing all materials, labour and T&P for fixing of 600mmx450mm bevelled edge mirror of superior glass mounted with backing A.C sheet & brass screws & washer complete as per specification and direction of E.I.C. | BI01010001010000000000000515BI0100001542 | ||
| 429 | 75.01 | Bevelled edge Mirror of size 600mmx450mm | BI01010001010000000000000515BI0100001543 | 89 | NO |
| 430 | 76 | Providing all materials, labour, T&P for fitting and fixing of 20 mm thick marble partition for urinal of following sizes including cutting, edge moulding, both side polishing including fixing on the wall after groove cutting & making good the damages. The cost inclusive of all taxes, transportation etc. all complete as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001544 | ||
| 431 | 76.01 | Marble partition Size-0.90mx0.60m | BI01010001010000000000000515BI0100001545 | 52 | No |
| 432 | 77 | Providing all materials , labour ,T&P and fittings and fixing of different water supply (CP on Brass) fitting as per IS mark & approved make of following sizes and specification with leak proof threaded joints with threadseal tape or any other method as required, including all taxes, duties, transportation etc., testing and rectification of defects after testing complete as per direction of Engineer-in-charge. Make : JAQUAR | BI01010001010000000000000515BI0100001546 | ||
| 433 | 77.01 | 15mm dia CP Bib cock (short body)with wall flange(Model No-CON-047KN) | BI01010001010000000000000515BI0100001547 | 10 | No |
| 434 | 77.02 | 15mm dia CP Angle stop cock with wall flange (Model no-CON-059KN) | BI01010001010000000000000515BI0100001548 | 249 | No |
| 435 | 77.03 | 15mm C.P.Pillar Cock (Model no-CON-011KN) | BI01010001010000000000000515BI0100001549 | 95 | No |
| 436 | 77.04 | 15mm C.P.Sink Cock with wall flange (Model no-CON-347NM) | BI01010001010000000000000515BI0100001550 | 1 | No |
| 437 | 77.06 | CP Soap dish(Model no-ACN 1131N) | BI01010001010000000000000515BI0100001552 | 89 | No |
| 438 | 77.07 | CP square Towel Ring(Model no-CAN-1121BN) | BI01010001010000000000000515BI0100001553 | 89 | No |
| 439 | 77.08 | Hand shower (Health Faucet),flexble tube&wall Bracket(Model No-ALD -565) | BI01010001010000000000000515BI0100001554 | 76 | No |
| 440 | 77.09 | CP Toilet Paper Holder (Model no-CAN-1153S) | BI01010001010000000000000515BI0100001555 | 76 | No |
| 441 | 77.1 | Urinal valve Auto Closing Systemwith bulit-in Control Cock & wall flange (Model No-SNR-CHR-51097) | BI01010001010000000000000515BI0100001556 | 52 | No |
| 442 | 77.11 | 32mm CP bootle trap(Model No-ALD769L250X190) | BI01010001010000000000000515BI0100001557 | 142 | No |
| 443 | 77.12 | CP Double Coat Hook (Model no-ACN1161N) | BI01010001010000000000000515BI0100001558 | 76 | No |
| 444 | 77.13 | Shower head (Model No-OHS-1989) | BI01010001010000000000000515BI0100001559 | 4 | No |
| 445 | 77.14 | Shower Arm (Model No-SHA-483) | BI01010001010000000000000515BI0100001560 | 4 | No |
| 446 | 77.15 | Shower wall mixure (Model No-CON-217KN) | BI01010001010000000000000515BI0100001561 | 4 | No |
| 447 | 77.16 | Grab bar for PH toilets (Model No-WAC-SAP=BG0800CS) | BI01010001010000000000000515BI0100001562 | 6 | No |
| 448 | 77.17 | Water heater - 25 ltrs (Model no-ELENA PRIME) | BI01010001010000000000000515BI0100001563 | 4 | No |
| 449 | 77.18 | 15mm dia steel braided connection pipe | BI01010001010000000000000515BI0100001564 | 174 | No |
| 450 | 77.19 | 32mm CP waste pipe (Model no-ALD-705) | BI01010001010000000000000515BI0100001565 | 52 | No |
| 451 | 78 | Providing all materials , labour ,T&P and fittings and fixing of Following Size on Extension piece (S.S/CP on Brass) approved make of following sizes and specification with leak proof threaded joints with spun yarn and white zinc or any other method as required including all taxes, duties, transportation etc., testing and rectification of defects after testing complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001566 | ||
| 452 | 78.01 | 15mmx65mm C.P./S.S Extension piece | BI01010001010000000000000515BI0100001567 | 300 | No |
| 453 | 79 | Providing all materials, labour & fitting and fixing 100mm PVC multi floor trap with cement mortar (1:4) with all taxes, duties etc. all complete as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001568 | ||
| 454 | 79.01 | 1000 mm PVC multi floor trap | BI01010001010000000000000515BI0100001569 | 160 | No |
| 455 | 80 | Providing all materials, labour & fitting and fixing 150x150mm size dia Stainless steel Cockroach floor Trap on top of floor traps with cement mortar (1:4) with all taxes, duties etc. all complete as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001570 | ||
| 456 | 80.01 | 150x150mm Cockroach Trap | BI01010001010000000000000515BI0100001571 | 160 | No |
| 457 | 81 | Providing all materials, labour, T&P for fitting and fixing of UPVC SWR pipes (Type-B) confirming to IS-13592/1992 with latest revision & ISI mark both below & above ground level or fixing on wall surface upto 2nd floor roof including scaffolding wherever necessary with requisite testing. The cost inclusive of all taxes, transportation, loading & unloading etc. all complete as per specification & direction of the Engineer-in-charge. Make : Ashirvad/ SUPREME/Astral | BI01010001010000000000000515BI0100001572 | ||
| 458 | 81.01 | 110mm dia UPVC SWR pipe with ISI mark | BI01010001010000000000000515BI0100001573 | 336 | Mtr |
| 459 | 81.02 | 75mm dia UPVC SWR pipe with ISI mark | BI01010001010000000000000515BI0100001574 | 475 | Mtr |
| 460 | 81.03 | 160mm dia UPVC SWR pipe with ISI mark | BI01010001010000000000000515BI0100001575 | 142 | Mtr |
| 461 | 82 | Providing all materials, labour, T&P, fitting and fixing of following dia UPVC SWR(Type-A) fittings of approved make confirming to IS 14735/1992 with ISI mark both below & above ground level or fixing on wall surface upto 2nd floor roof including scaffolding wherever necessary with requisite testing. The cost inclusive of all taxes, transportation, loading & unloading etc. all complete as per specification & direction of the Engineer-in-charge. Make : Ashirwad/ ASTRAL/SUPREME | BI01010001010000000000000515BI0100001576 | ||
| 462 | 82.01 | 110mm S Trap | BI01010001010000000000000515BI0100001577 | 80 | Nos |
| 463 | 82.02 | 110mm P Trap | BI01010001010000000000000515BI0100001578 | 60 | Nos |
| 464 | 82.03 | 110mm Cross Tee | BI01010001010000000000000515BI0100001579 | 30 | Nos |
| 465 | 82.04 | 110mm Single Tee with door | BI01010001010000000000000515BI0100001580 | 30 | Nos |
| 466 | 82.05 | 110mm Single Tee Plain | BI01010001010000000000000515BI0100001581 | 30 | Nos |
| 467 | 82.06 | 110mm Plain Bend | BI01010001010000000000000515BI0100001582 | 30 | Nos |
| 468 | 82.07 | 110mm Door Bend | BI01010001010000000000000515BI0100001583 | 30 | Nos |
| 469 | 82.08 | 110mm Vent Cowl | BI01010001010000000000000515BI0100001584 | 47.5 | Nos |
| 470 | 82.09 | PVC clamp suitable for 110mm dia pipe | BI01010001010000000000000515BI0100001585 | 100 | Nos |
| 471 | 82.1 | 110x75 Reducing Y without door | BI01010001010000000000000515BI0100001586 | 30 | Nos |
| 472 | 82.11 | 75mm Cross Tee | BI01010001010000000000000515BI0100001587 | 25 | Nos |
| 473 | 82.12 | 75mm Single Tee Plain | BI01010001010000000000000515BI0100001588 | 25 | Nos |
| 474 | 82.13 | 75mm Plain Bend | BI01010001010000000000000515BI0100001589 | 25 | Nos |
| 475 | 82.14 | 75mm Door Bend | BI01010001010000000000000515BI0100001590 | 25 | Nos |
| 476 | 82.15 | 75mm Vent Cowl | BI01010001010000000000000515BI0100001591 | 6 | Nos |
| 477 | 82.16 | PVC clamp suitable for 75mm dia pipe | BI01010001010000000000000515BI0100001592 | 100 | Nos |
| 478 | 82.17 | 75 mm End cap | BI01010001010000000000000515BI0100001593 | 10 | Nos |
| 479 | 82.18 | 110 mm End cap | BI01010001010000000000000515BI0100001594 | 10 | Nos |
| 480 | 82.19 | 160 mm end cap | BI01010001010000000000000515BI0100001595 | 10 | Nos |
| 481 | 82.2 | 160mm Cross Tee | BI01010001010000000000000515BI0100001596 | 20 | Nos |
| 482 | 82.21 | 160mm Single Tee with door | BI01010001010000000000000515BI0100001597 | 20 | Nos |
| 483 | 82.22 | 160mm Single Tee Plain | BI01010001010000000000000515BI0100001598 | 20 | Nos |
| 484 | 82.23 | 160mm Plain Bend | BI01010001010000000000000515BI0100001599 | 20 | Nos |
| 485 | 82.24 | 160mm Door Bend | BI01010001010000000000000515BI0100001600 | 20 | Nos |
| 486 | 82.25 | 160mm Vent Cowl | BI01010001010000000000000515BI0100001601 | 6 | Nos |
| 487 | 82.26 | PVC clamp suitable for 160mm dia pipe | BI01010001010000000000000515BI0100001602 | 50 | Nos |
| 488 | 82.27 | 75 mm threaded cleanout plug | BI01010001010000000000000515BI0100001603 | 1 | Nos |
| 489 | 82.28 | 110 mm threaded cleanout plug | BI01010001010000000000000515BI0100001604 | 1 | Nos |
| 490 | 82.29 | 160 mm threaded cleanout plug | BI01010001010000000000000515BI0100001605 | 1 | Nos |
| 491 | 83 | Providing all materials, labour, T&P for fitting and fixing of UPVC 6 kg/cm2 pressure pipes IS4985 for waste connection from wash basin,kitchen sinks with latest revision & ISI mark both below & above ground level or fixing on wall surface upto 2nd floor roof including scaffolding wherever necessary with requisite testing. The cost inclusive of all taxes, transportation, loading & unloading etc. all complete as per specification & direction of the Engineer-in-charge. Make : SUPREME | BI01010001010000000000000515BI0100001606 | ||
| 492 | 83.01 | 40mm dia UPVC pressure pipe | BI01010001010000000000000515BI0100001607 | 200 | Mtr |
| 493 | 83.02 | 50mm dia UPVC pressure pipe | BI01010001010000000000000515BI0100001608 | 87 | Mtr |
| 494 | 84 | Supply and fixing,testing commissioning of aquaguard Magna HD 7ltr RO + Uv water purifier and black comolete as per specification & direction of the engineer in charge. | BI01010001010000000000000515BI0100001609 | 8 | Nos |
| 495 | 85 | Fixing Rotationnal moulded polythylene cylindrical vertical water storage tanks conforming to IS:12701--1996 including cutting holes through the tank and fiaxing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5meters aboe ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in chrgees. | BI01010001010000000000000515BI0100001610 | ||
| 496 | 85.01 | 1000 litres capacity | BI01010001010000000000000515BI0100001611 | 10 | Nos |
| 497 | 86 | PH EXTERNAL | BI01010001010000000000000515BI0100001612 | ||
| 498 | 87 | Laying (to level or slopes)and jointing with rubber rings pre -cast reinforced socket and spigot concrete pipes class NP2 conforming to IS :458-2003 suitable for suitable for rubber ring roll on joint of the following internal diameter as per specification complete (earth in trenches to be paid separately) | BI01010001010000000000000515BI0100001613 | ||
| 499 | 87.01 | 200 mm dia | BI01010001010000000000000515BI0100001614 | 117 | Rmt. |
| 500 | 87.02 | 150 mm dia | BI01010001010000000000000515BI0100001615 | 424 | Rmt. |
| 501 | 87.03 | 100 mm dia | BI01010001010000000000000515BI0100001616 | 58 | Rmt. |
| 502 | 88 | Providing all material, labour, T&P and construction of Gully Trap chamber of size as mentioned below with 250mm nominal size Fly Ash Brick having crushing strength not less than 75kg/sqcm in CM 1:4 over a bed of 100mm thick C.C. (1:3:6) using 40mm size HG metal, plastering with 12mm thick cement plaster with cement punning in cement mortar 1:4 on inner surface and 12mm thick cement plaster in cement mortar (1:4) on external surface,fitting & fixing of PVC Gully Trap and pre-cast factory made (SFRC) cover with frame of opening size 300mmx300mm, moulding and shaping the channel & benching with C.C (1:2:4) with hard granite chips 12mm size, earth work excavation in all kinds of soil & rock and filling the cavity of the chamber with excavated & selected earth levelling the surface around the chamber with disposal of surplus earth within 50m. lead as per specification, design & drawing including cost of curing and all taxes, royalty, cost, conveyance etc. all complete as per specification & direction of EIC. | BI01010001010000000000000515BI0100001617 | ||
| 503 | 88.01 | Inner size 300mmx300mmx450mm depth Gully Trap chamber | BI01010001010000000000000515BI0100001618 | 10 | Nos. |
| 504 | 89 | Providing all materials, labour, T&P required for construction of RCC M-25 man hole chamber of following sizes having cube strength 250 Kg/cm2 at 28 days confirming to IS-456/2000 & IS-3370 at all locations & height using h.g. stone aggregate (Crusher broken) of 20mm & down size including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC base slab, all side walls & roof slab shall be not less than 150mm & 125mm (avg.) respectively. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all bracing, ties, anchorage & supports and removing the same after required paid & placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires (18 to 20 gauge soft drawn & cold annealed). | BI01010001010000000000000515BI0100001619 | ||
| 505 | 89.01 | PCC 1:3:6 with 40mm size h.g.c.b. metal of 100mm thick, moulding & shaping the channel & benching with C.C. 1:2:4 with 12mm size h.g.c.b. chips, 12mm thick cement plaster 1:3 with cement punning on inner wall surface, earth work excavation in all types of soil/rock including cement concrete cutting as per site condition, filling the foundation base with sand duly watered & rammed, providing, fitting & fixing of pre-cast factory made man hole cover with frame (SFRC medium duty) for clear opening 500mm dia, providing, fitting & fixing of poly propylene steel reinforced man hole steps of approved quality & size in two parallel line of 300mm spacing in vertical wall with centre to centre 375mm (staggered) etc.all complete as per specification & direction of EIC. | BI01010001010000000000000515BI0100001620 | ||
| 506 | 89.02 | Manhole chamber of Inner size 800mmx900mmx 600mm depth. | BI01010001010000000000000515BI0100001621 | 2 | Nos. |
| 507 | 89.03 | Manhole chamber of Inner size 900mmx900mmx 900mm depth. | BI01010001010000000000000515BI0100001622 | 24 | Nos. |
| 508 | 89.04 | Extra for every additional depth of 0.10mtr. or part there of manhole size 900mmx900mm from 900mm depth upto 1500mm depth. | BI01010001010000000000000515BI0100001623 | 12 | Mtr. |
| 509 | 90 | Earth work in hard soil within 50m initial lead & 1.5m initial lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of EIC. | BI01010001010000000000000515BI0100001624 | ||
| 510 | 90.01 | Upto 1.50m initial lift | BI01010001010000000000000515BI0100001625 | 233.64 | Cum. |
| 511 | 91 | Earth work in stoney earth & gravels mixed with stone boulders not exceeding 0.014 cum in volume within 50m initial lead & 1.50m lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of EIC. | BI01010001010000000000000515BI0100001626 | ||
| 512 | 91.01 | Upto 1.50m initial lift | BI01010001010000000000000515BI0100001627 | 118.02 | Cum. |
| 513 | 92 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing & levelling & benching the bed not exceeding 1.50m depth & depositing the soil within initial lead of 50m & as per specification approved by the EIC. | BI01010001010000000000000515BI0100001628 | ||
| 514 | 92.01 | Upto 1.50m initial lift | BI01010001010000000000000515BI0100001629 | 116.82 | Cum. |
| 515 | 93 | Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. | BI01010001010000000000000515BI0100001630 | 463.6 | Cum |
| 516 | 94 | Providing all materials,labour,T&P for construction of following size Cement Concrete (1:2:4) Pedestal with 12mm size h.g.c.b. chips, PCC 1:3:6 with 40mm size h.g.c.b. metal, Centering & Shuttering etc. as per approved design & drawing for RCC pipe. The cost inclusive of all taxes, royality, hire & running charges of all machineries, Transportation charges with all consumables etc. all complete as per specification & direction of EIC. | BI01010001010000000000000515BI0100001631 | ||
| 517 | 94.01 | Cement Concrete Pedestal of size 600mmx250mmx400mm ht. | BI01010001010000000000000515BI0100001632 | ||
| 518 | 94.02 | for 110mm dia RCC pipe | BI01010001010000000000000515BI0100001633 | 26 | Nos. |
| 519 | 94.03 | Cement Concrete Pedestal of size 600mmx250mmx450mm ht. | BI01010001010000000000000515BI0100001634 | ||
| 520 | 94.04 | for 160mm dia RCC pipe | BI01010001010000000000000515BI0100001635 | 212 | Nos. |
| 521 | 94.05 | Cement Concrete Pedestal of size 600mmx250mmx450mm ht. | BI01010001010000000000000515BI0100001636 | ||
| 522 | 94.06 | for 200mm dia RCC pipe | BI01010001010000000000000515BI0100001637 | 58.5 | Nos. |
| 523 | 95 | SPECTIC TANK | BI01010001010000000000000515BI0100001638 | ||
| 524 | 96 | Earth work in excavation of foundation trenches in all kinds of soil by mechanical means (Hydraulic Excavator) / manually including moorum, stoney earth and earth mixed with boulders except sheet rock and boulders including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering & dewatering (if required) with cost of labour, hire & running charges of water pumps and machinaries,sundries & T & P required for the work complete as directed by the Engineer in charge. | BI01010001010000000000000515BI0100001639 | 552 | CUM |
| 525 | 97 | Filling foundation trenches and plinth with coarse river SAND and well watered and compacted and top surface dressed and leveled to proper gradient in layers of 0.225 mtr including cost of all materials, conveyance, all taxes and royalties, loading and unloading, including cost of all labour, T&P, sundries etc. complete as per direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001640 | 9.9 | CUM |
| 526 | 98 | Disposal of surplus excavated materials within the area specified & directed by BDA / EIC (all kinds of soil, boulders, concrete or any other excavated materials) including all lifts, spreading in layers, breaking clods and leveling to disposal ground arranged by the contractor inclusive from the site of excavation to the site of disposition(upto take 10 Km.) etc. complete all as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001641 | 559.63 | CUM |
| 527 | 99 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional anti- termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge. | BI01010001010000000000000515BI0100001642 | 101.75 | SQM |
| 528 | 100 | Providing and laying in plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.\n | BI01010001010000000000000515BI0100001643 | 9.9 | CUM |
| 529 | 101 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). | BI01010001010000000000000515BI0100001644 | 122.4 | CUM |
| 530 | 102 | Providing strong, rigid, leveled, and plumbed centering and shuttering to required shape and size , for floors with ply or steel centering materials with all necessary bracing and tiles and supports with leveling centering covered with plastic sheet with provisions necessary holes and pockets for electrical conduits, pipes, P.H. pipes, for hooks or boxes, switch and board insert plates, clamps and extension bars etc., including dismantling the same after the required interval from the date of casting including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001645 | ||
| 531 | 102.01 | septic tank | BI01010001010000000000000515BI0100001646 | 18.9 | Sqm |
| 532 | 102.02 | Wall 300 mm thick | BI01010001010000000000000515BI0100001647 | 340 | Sqm |
| 533 | 102.03 | Wall 300 mm thick | BI01010001010000000000000515BI0100001648 | 80 | Sqm |
| 534 | 102.04 | Beam below baffle wall | BI01010001010000000000000515BI0100001649 | 80 | Sqm |
| 535 | 102.05 | Cover Slab | BI01010001010000000000000515BI0100001650 | 68 | Sqm |
| 536 | 103 | Supplying cutting, bending,binding, HYSD Fe 500 grade TMT ductile reinforcement bars of required diameter and approved quality, with straightening, lifting and placing in position as per design complete including cost,conveyance,taxes of reinforcement bars ,binding wires 18 to 20 gauge ,all labour, sundries, T&P and scaffolding etc. complete (linear measurement will be taken and quantity will be calculated on standard weight) for all height and as directed by Engineer -In-Charge. | BI01010001010000000000000515BI0100001651 | 122.4 | Qntl |
| 537 | 104 | 12mm cement plaster on the external surface of brick masonry walls with cement mortar of mix (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth to proper plumbs and level including cost of all materials, conveyance, loading and unloading all taxes, and royalties all labour scaffolding, watering and curing, sundries and T&P etc. complete .and as directed by Engineer -In-Charge. | BI01010001010000000000000515BI0100001652 | 636 | SQM |
| 538 | 105 | Supplying and fixing of SFRC manhole covers of size 600x600mm ultimate load as per IS :12592,part-1 heavy duty -20 MT and frames with suitable mild steel rims to prevent chipping of edges and enables clear opening with easy lifting hooks which are duly protected against corrosion. | BI01010001010000000000000515BI0100001653 | 1 | Nos |
| 539 | 106 | SOAK PIT | BI01010001010000000000000515BI0100001654 | ||
| 540 | 107 | Earth work in excavation of foundation trenches in all kinds of soil by mechanical means (Hydraulic Excavator) / manually including moorum, stoney earth and earth mixed with boulders except sheet rock and boulders including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering & dewatering (if required) with cost of labour, hire & running charges of water pumps and machinaries,sundries & T & P required for the work complete as directed by the Engineer in charge. | BI01010001010000000000000515BI0100001655 | 37.29 | CUM |
| 541 | 108 | Filling foundation trenches and plinth with coarse river SAND and well watered and compacted and top surface dressed and leveled to proper gradient in layers of 0.225 mtr including cost of all materials, conveyance, all taxes and royalties, loading and unloading, including cost of all labour, T&P, sundries etc. complete as per direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001656 | 3.11 | CUM |
| 542 | 109 | Disposal of surplus excavated materials within the area specified & directed by BDA / EIC (all kinds of soil, boulders, concrete or any other excavated materials) including all lifts, spreading in layers, breaking clods and leveling to disposal ground arranged by the contractor inclusive from the site of excavation to the site of disposition(upto take 10 Km.) etc. complete all as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001657 | 37.29 | CUM |
| 543 | 110 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional anti- termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge. | BI01010001010000000000000515BI0100001658 | 5 | SQM |
| 544 | 111 | Providing and laying in position plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.\n | BI01010001010000000000000515BI0100001659 | 3.11 | cum |
| 545 | 112 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). | BI01010001010000000000000515BI0100001660 | 6.22 | CUM |
| 546 | 113 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001661 | 4.66 | Cum |
| 547 | 114 | Providing strong, rigid, leveled, and plumbed centering and shuttering to required shape and size , for floors with ply or steel centering materials with all necessary bracing and tiles and supports with leveling centering covered with plastic sheet with provisions necessary holes and pockets for electrical conduits, pipes, P.H. pipes, for hooks or boxes, switch and board insert plates, clamps and extension bars etc., including dismantling the same after the required interval from the date of casting including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001662 | ||
| 548 | 114.01 | Foundations, footings, bases of columns, etc. for mass concrete | BI01010001010000000000000515BI0100001663 | 31.08 | Sqm |
| 549 | 115 | Supplying cutting, bending,binding, HYSD Fe 500 grade TMT ductile reinforcement bars of required diameter and approved quality, with straightening, lifting and placing in position as per design complete including cost,conveyance,taxes of reinforcement bars ,binding wires 18 to 20 gauge ,all labour, sundries, T&P and scaffolding etc. complete (linear measurement will be taken and quantity will be calculated on standard weight) for all height and as directed by Engineer -In-Charge. | BI01010001010000000000000515BI0100001664 | 6.22 | Qntl |
| 550 | 116 | Fly ash Brick masonry work in super structure using Fly ash Brick having crushing strength not less than 75Kg /Cm2 in cement mortar (1:6) immersing the bricks for minimum six hours in water before use with all necessary projections, splays, cutting, circular moulding, corbelling etc. including cost, conveyance taxes royalties, loading & unloading of all materials & all labour and scaffolding, watering & curing, sundries T&P etc. complete as per direction of the Engineer-in-Charge . | BI01010001010000000000000515BI0100001665 | 6.82 | CUM |
| 551 | 117 | 12mm cement plaster on the external surface of brick masonry walls with cement mortar of mix (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth to proper plumbs and level including cost of all materials, conveyance, loading and unloading all taxes, and royalties all labour scaffolding, watering and curing, sundries and T&P etc. complete .and as directed by Engineer -In-Charge. | BI01010001010000000000000515BI0100001666 | 27.31 | Sqm |
| 552 | 119 | BOREWELL | BI01010001010000000000000515BI0100001668 | ||
| 553 | 120 | conducting reconnaissance survay, integrated hydrological & geophysical(electrical ressistivity method) survey and selection of potential source for exploration of Ground water including selection and recommendation of site for drilling production wells in selected area. | BI01010001010000000000000515BI0100001669 | 1 | job |
| 554 | 121 | Labour for drilling a perfects vertical bore hole of specified dia for a specififed depth below grround level through consolidated and unconsolidated rock with down the hole hammer drillin rigs or combindation drilling rigs(1200 cfm/300psl) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories, tools and plant and consumables etc. for lowering of 200mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medimum, hard and boulder formatiobn ( GI/PVC casing pipes if required to prevent collaspse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tube well.) | BI01010001010000000000000515BI0100001670 | 60 | Mtr. |
| 555 | 122 | Lowering the fiollowing size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfect vertical posityion, including cutting and threading pipe and slotted pipe and supplying and fixing all jointing materials, tools and plant etc complete and keeping the top of the casing pipe threaded including plugging tube wells to preventy entry of foreigh materials from above. | BI01010001010000000000000515BI0100001671 | 45 | Mtr. |
| 556 | 124 | Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipement and labour as per the direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001673 | 1 | No |
| 557 | 125 | Supplying all materials ,labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level (as per drawing) to plug the bore hole including cost of cement etc.all complete as per direction in charge.Minimum one meter of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing. | BI01010001010000000000000515BI0100001674 | 45 | Mtr. |
| 558 | 126 | Providing all material, labour, T&P and construction of chamber of size1400X1400X1200MM as mentioned below with 250mm nominal size Fly Ash Brick having crushing strength not less than 75kg/sqcm in CM 1:4 over a bed of 100mm thick C.C. (1:3:6) using 40mm size HG metal, plastering with 12mm thick cement plaster with cement punning in cement mortar 1:4 on inner surface and 12mm thick cement plaster in cement mortar (1:4) on external surface. Including earth work excavation in all kinds of soil & rock and filling the cavity of the chamber with excavated & selected earth levelling the surface around the chamber with disposal of surplus earth within 50m. lead as per specification, design & drawing including cost of curing and all taxes, royalty, cost, conveyance etc. all complete as per specification & direction of EIC. | BI01010001010000000000000515BI0100001675 | 1 | No |
| 559 | 127 | Supply , Instalation , testing & commissioning of 3 -phase . 50Hz Submerible pump set of required head 75mtr, 7.5 HP & discharge including HDPE delivery pipes of 10kg/cm² of required head 75mtr, 7.5HP & discharge including HDPE delivery pipes of 10kg/cm² of material grade PE-80 , suitable size of three core flat cable with Bore hunched copper conductor insulated sheated with PVC for submersible Motor with voltage grade upto 1100 Volt confirming to IS-694/1990 of required length, control panel & required accessories suitable for 200x150mm size Production Well. | BI01010001010000000000000515BI0100001676 | 1 | No |
| 560 | 128 | FIRE FIGHTING | BI01010001010000000000000515BI0100001677 | ||
| 561 | 129 | Pumps and Equipments | BI01010001010000000000000515BI0100001678 | ||
| 562 | 130 | Providing ,fixing , testing and commissioning of diesel Engine driven common stand by pump, horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 2280LPM at 70 MWC. The pump shall coupled to suitable HP of Diesel engine radiator water cooled type with speed of 1800 RPM and complete set shall be mounted on common base frame. Batteries & battery leads with stand, Fuel tank ( for 6 Hrs. operation & double container type) with stand & gauge glass, Fuel piping with valves. The quoted rate shall includes water re - circulation piping, Pressure relief valve, radiator water cooling piping(if required) coupling guard, and suitable size of metal expansion bellows at both side of the pumps ,anti vibration pad and other standard accessories, foundation bolts, etc. complete as per the manufactures recommendations.\nMAKE-(PUMP)KIRLOSKAR,GRUNDFOS,WILO | BI01010001010000000000000515BI0100001679 | 1 | Nos |
| 563 | 131 | Providing ,fixing , testing and commissioning of electrical motor driven Jockey pump of horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 180 LPM at 70 MWC.The pump shall be coupled to TEFC motor of suitable HP with speed of 2900 RPM and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of compound gauge and suitable size of metal expansion bellows at both side of the pumps ,anti vibration pad, water re-circulation arrangement, pressure relief valve, coupling, coupling guard, foundation bolts etc,complete as per the manufactures recommendations\nMAKE-(PUMP)KIRLOSKAR,GRUNDFOS,WILO\n | BI01010001010000000000000515BI0100001680 | 1 | Nos |
| 564 | 132 | Providing ,fixing , testing and commissioning of electrical motor driven main pump of horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 2280 LPM at 70 MWC.the pump shall be coupled to TEFC motor of suitable hp with speed of 2900 rpm and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of compound gauge and suitable size of metal expansion bellows at both side of the pumps ,anti vibration pad, water re-circulation arrangement, pressure relief valve, coupling, coupling guard, foundation bolts etc, complete as per the manufactures recommendations( one each for hydrant & sprinkler system).MAKE-(PUMP)KIRLOSKAR,GRUNDFOS,WILO | BI01010001010000000000000515BI0100001681 | 1 | Nos |
| 565 | 133 | Providing, fixing ,testing and commissioning of compartmentalized common control panel with mechanical and electrical interlock facility for the fire pumps. All the components shall be housed in a common cubical made of 16 SWG. M.S. sheet with required stiffeners). The panel shall be powder coated of approved color both inside & outside. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height.\nIncoming Feeder\na. 2 nos. 400 Amps TPN MCCB (50 KA) and shall be motor operated type \nb. 2 Sets of 400 Amps. TPN Al. Bus bars with color coded heat shrinkable PVC sleeves.\nc. 1 Set of RYB indicating lamps with individual MCB.\nd. 1 No 0-400 Amps. Ammeter with selector switch and suitable rated current transformers.\ne. 1 No. 0 - 400V. Voltmeter with selector switch | BI01010001010000000000000515BI0100001682 | 1 | Nos |
| 566 | 133.01 | Outgoing | BI01010001010000000000000515BI0100001683 | ||
| 567 | 133.02 | Feeder For DG Driven Pump - 1 Nos \n1. 20Amps DPMCB - 2 Nos.\n2. Battery charger with transformer with rectifier resistance DC ammeter \n3. DC voltmeter, Trickle / booster / off selector switch -1 No\n4. Following indication lamps- 1 sets\nPhase indication, Battery charger on, Over load relay, DC supply on,control switch on , Engine fails to start, Pump on, Low oil pressure,High water temperature and Auto manual selector switch\n5. Following push button stations - 1 Sets\nEngine Start,Engine Stop, Engine hooter, Engine fault reset, Selector switches for Engine control & mode selector\n6. Hooter Industrial type for audio alarm - 1 No. | BI01010001010000000000000515BI0100001684 | ||
| 568 | 133.03 | Feeder For Jockey Pump - 1 Nos \na. 1 Nos. 32A TP MCCB without releases\nb. DOL with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons.\nc. 1 No. Auto manual selector switch\nd. 2 Nos. of NO/NC contacts for extending the status to the Fire alarm panel | BI01010001010000000000000515BI0100001685 | ||
| 569 | 133.04 | Feeder For Main Pump - 1 Nos \na. 1 Nos. 200A TP MCCB without releases\nb. DOL with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons.\nc. 1 No. Auto manual selector switch\nd. 2 Nos. of NO/NC contacts for extending the status to the Fire alarm panel | BI01010001010000000000000515BI0100001686 | ||
| 570 | 134 | Supplying, installing ,testing and commissioning of FRLS,PVC outer sheathed, steel armored, aluminum conductor, 1100 Vgrade power cables with glands etc.The cables shall be laid in tray / Hume pipe / in trenches/on walls/ floor etc. as required. For cables laid out door the rate shall include earth excavation providing brick and sand protection, refilling and compacting the earth.The rate shall excludes tray & Hume pipes.The minimum size & length of the cables shall be considered as required for the complete system. | BI01010001010000000000000515BI0100001687 | ||
| 571 | 134.01 | 3.5C x 25 Sqmm. Copper cable Diesel engines | BI01010001010000000000000515BI0100001688 | 40 | Rmt |
| 572 | 134.02 | 4 C x 16 Sqmm. Aluminum cable Jockey pumps | BI01010001010000000000000515BI0100001689 | 40 | Rmt |
| 573 | 134.03 | 2 C x 2.5 Sqmm.Copper cable for Instrumentation | BI01010001010000000000000515BI0100001690 | 60 | Rmt |
| 574 | 134.04 | 3.5C x 95 sq.mm Aluminum cable for main pumps | BI01010001010000000000000515BI0100001691 | 60 | Rmt |
| 575 | 135 | Providing ,fixing , testing and commissioning of perforated G.I.sheet cable tray with necessary angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size / length of the tray shall be suitable for laying the above mentioned cables. | BI01010001010000000000000515BI0100001692 | ||
| 576 | 135.01 | Size 200mmX50mm | BI01010001010000000000000515BI0100001693 | 40 | Rmt |
| 577 | 135.02 | Size 100mmX50mm | BI01010001010000000000000515BI0100001694 | 20 | Rmt |
| 578 | 136 | Providing ,fixing , testing and commissioning of G.I. Earthing strips of 50mm x 6mm thick, strip shall be run on floor / ceiling / walls, from the MCC panel to all equipments as per standard with necessary accessories as required. | BI01010001010000000000000515BI0100001695 | 60 | Rmt |
| 579 | 137 | Providing ,fixing , testing and commissioning of C.I.flanged \"Y\" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete. | BI01010001010000000000000515BI0100001696 | ||
| 580 | 137.01 | 250mm dia. | BI01010001010000000000000515BI0100001697 | 2 | Nos |
| 581 | 138 | Providing ,fixing , testing and commissioning of PN 10 C.I.Gate valves as per IS:14846 with rising spindle type with flanges, bolts, nuts, washers, gaskets etc. | BI01010001010000000000000515BI0100001698 | ||
| 582 | 138.01 | 100mm nominal dia | BI01010001010000000000000515BI0100001699 | 1 | Nos |
| 583 | 138.02 | 200mm nominal dia | BI01010001010000000000000515BI0100001700 | 2 | Nos |
| 584 | 138.03 | 250mm nominal dia | BI01010001010000000000000515BI0100001701 | 2 | Nos |
| 585 | 139 | Providing ,fixing , testing and commissioning of PN 16 swing check type C.I. Non-return valves as per IS:5312 with required flanges, nuts, bolts and gaskets etc. complete. | BI01010001010000000000000515BI0100001702 | ||
| 586 | 139.01 | 80 mm nominal dia | BI01010001010000000000000515BI0100001703 | 1 | Nos |
| 587 | 139.02 | 150 mm nominal dia | BI01010001010000000000000515BI0100001704 | 2 | Nos |
| 588 | 140 | Providing ,fixing , testing and commissioning of PN 16 CI butterfly valves as per BS 5155 standard slim seal lever/gear operated type with required flanges, nuts, bolts etc. complete. | BI01010001010000000000000515BI0100001705 | ||
| 589 | 140.01 | 80 mm nominal dia - Lever operated | BI01010001010000000000000515BI0100001706 | 1 | Nos |
| 590 | 140.02 | 150mm nominal dia - Lever operated | BI01010001010000000000000515BI0100001707 | 6 | Nos |
| 591 | 140.03 | 200 mm nominal dia -Gear Operated Type | BI01010001010000000000000515BI0100001708 | 1 | Nos |
| 592 | 141 | Providing ,fixing , testing and commissioning of 150 mm dia electronic digital display flow meter on Test line to measure 175 % of pump flow. | BI01010001010000000000000515BI0100001709 | 1 | Nos |
| 593 | 142 | Providing ,fixing , testing and commissioning of Pressure switches of suitable range for pump sets with Ball valves, Fittings like unions / colors / reducers etc. | BI01010001010000000000000515BI0100001710 | 3 | Nos |
| 594 | 143 | Supplying, installing ,testing and commissioning of Pressure gauges of suitable range for pump sets with Ball valves, siphon, Fittings like unions / colors / reducers etc. Glycerin filled pressure gauges to use on pump discharge lines. | BI01010001010000000000000515BI0100001711 | 3 | Nos |
| 595 | 144 | Providing ,fixing , testing and commissioning of GI Pipes confirming to IS 1239 Pt - I Heavy grade up to 150 mm & 3589,6mm thick for above 150 mm dia, with painting, suitable type of supports( fabricated by angles, channels, flats etc, with painting with fasteners), anchor fasteners, bolts nuts ( Galvanized), clamps, \"U\" bolts, malleable specials such as Reducers,Tees, elbows (as per IS 1239 Pt II), flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also inclusive of civil work in walls and making them good with filler material and finished in cement mortar etc. complete.Vendor shall consider the 2 hr fire rated fire sealant material where the pipes are passing through the fire walls /compartments as per the IS code.MAKE-SAIL,JINDAL,TATA | BI01010001010000000000000515BI0100001712 | ||
| 596 | 144.01 | 25mm nominal dia | BI01010001010000000000000515BI0100001713 | 25 | Rmt |
| 597 | 144.02 | 50mm nominal dia | BI01010001010000000000000515BI0100001714 | 25 | Rmt |
| 598 | 144.03 | 80mm nominal dia | BI01010001010000000000000515BI0100001715 | 6 | Rmt |
| 599 | 144.04 | 100mm nominal dia | BI01010001010000000000000515BI0100001716 | 6 | Rmt |
| 600 | 144.05 | 150mm nominal dia | BI01010001010000000000000515BI0100001717 | 24 | Rmt |
| 601 | 144.06 | 200mm nominal dia | BI01010001010000000000000515BI0100001718 | 18 | Rmt |
| 602 | 144.07 | 250mm nominal dia | BI01010001010000000000000515BI0100001719 | 12 | Rmt |
| 603 | 145 | Providing ,fixing , testing and commissioning of Exhaust pipe of dia 150mm MS medium grade for Diesel engine with mineral wool insulation with aluminum cladding including necessary supports through shaft up to terrace level | BI01010001010000000000000515BI0100001720 | 60 | Rmt |
| 604 | 146 | Providing ,fixing , testing and commissioning of precharged air vessel (size 350 mm dia & 2000 mm height) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required. | BI01010001010000000000000515BI0100001721 | 1 | Nos |
| 605 | 147 | Providing ,fixing , testing and commissioning of approved make 20mm dia. With automatic air release valve with unions and ball valve etc. complete. | BI01010001010000000000000515BI0100001722 | 2 | Nos |
| 606 | 148 | Hydrant System | BI01010001010000000000000515BI0100001723 | ||
| 607 | 149 | Providing ,fixing , testing and commissioning of Single headed hydrant valve(Internal) as per IS 5290, made of gunmetal with 63 mm dia instantaneous out & 80 mm dia fanged inlet , Blank cap , chain and hand wheel etc complete and a) 2 lengths of 15 M long, 63mm dia RRL hose,b)1 no. Gun metal short branch pipe with nozzle,c)Hose reel drum of swinging type with 19mm dia Rubber braided hose of 36M length with ball valve and Shut off nozzle with required accessories to install the equipments etc., complete. | BI01010001010000000000000515BI0100001724 | 22 | Nos |
| 608 | 150 | Providing ,fixing , testing and commissioning of Fire duct Shutter fabricated out of M.S sheet and frame, door (SWG 16) and powder coated of approved red color both inside and out side. The size shall be 900mm x 1200 mm min. & fixed with 6 mm thick Glass, and key with suitable Rubber beading and Locking arrangement as per the tender drawings. | BI01010001010000000000000515BI0100001725 | 22 | Nos |
| 609 | 151 | Providing ,fixing , testing and commissioning of fire brigade inlet connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main. Quoted rate shall be included with C.I. Butterfly valve, C.I. Non-return valve and M.S. cabinet of suitable size with mounting supports etc. complete. | BI01010001010000000000000515BI0100001726 | 1 | Nos |
| 610 | 152 | Providing ,fixing , testing and commissioning of Single headed hydrant valve(External) as per IS 5290, made of gunmetal with 63 mm dia instantaneous out & 80 mm dia fanged inlet , Blank cap , chain and hand wheel etc complete and 1) 2 lengths of 15 M long, 63mm dia CP hose,2)1 no. Gun metal short branch pipe with nozzle. | BI01010001010000000000000515BI0100001727 | 12 | Nos |
| 611 | 153 | Providing ,fixing , testing and commissioning of M.S. Hose cabinet stand mounted type fabricated out of M.S. sheet of 16 SWG with powder coated of approved red color both inside and out side and glass fronted ( 6mm thick glass with rubber beading) door and size of the cabinet shall be 600mm x 750 mm x 250 mm Quoted rate shall be includes suitable stand for mounting, all fasteners etc. | BI01010001010000000000000515BI0100001728 | 12 | Nos |
| 612 | 154 | Providing ,fixing , testing and commissioning of approved make 20mm dia. With automatic air release valve with unions and ball valve etc. complete. | BI01010001010000000000000515BI0100001729 | 4 | Nos |
| 613 | 155 | Providing ,fixing , testing and commissioning of GI. Pipes confirming to IS 1239 Pt - I Heavy grade up to 150 mm & 3589,6mm thick for above 150 mm dia, with painting, suitable type of supports( fabricated by angles, channels, flats etc, with painting with fasteners), anchor fasteners, bolts nuts ( Galvanized), clamps, \"U\" bolts, malleable specials such as Reducers, Tees, elbows (as per IS 1239 Pt II), flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also inclusive of civil work in walls and making them good with filler material and finished in cement mortar etc. complete.Vendor shall consider the 2 hr fire rated fire sealant material where the pipes are passing through the fire walls /compartments as per the IS code. | BI01010001010000000000000515BI0100001730 | ||
| 614 | 155.01 | 80mm nominal dia | BI01010001010000000000000515BI0100001731 | 18 | Rmt |
| 615 | 155.02 | 150mm nominal dia | BI01010001010000000000000515BI0100001732 | 318 | Rmt |
| 616 | 156 | Providing ,fixing , testing and commissioning of G.I. Pipes confirming to IS 1239 Pt - I Heavy grade up to 150 mm & 3589,6mm thick for above 150 mm dia, with suitable type of supports, malleable specials such as Reducers,Tees, elbows(as per IS 1239 Pt II), flanges. Including cutting, Welding as per drawings. The rate quoted should be included with anticorrosive treatment with 4 mm thick polymer corrosion resistant tape as per IS 10221, overlap shall be maintained at 15mm minimum. | BI01010001010000000000000515BI0100001733 | ||
| 617 | 156.01 | 150mm nominal dia | BI01010001010000000000000515BI0100001734 | 400 | Rmt |
| 618 | 156.02 | 80mm nominal dia | BI01010001010000000000000515BI0100001735 | 90 | Rmt |
| 619 | 157 | Providing ,fixing , testing and commissioning of PN 16 CI butterfly valves as per BS 5155 slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. | BI01010001010000000000000515BI0100001736 | ||
| 620 | 157.01 | 100mm nominal dia | BI01010001010000000000000515BI0100001737 | ||
| 621 | 157.02 | 150mm nominal dia | BI01010001010000000000000515BI0100001738 | 11 | Nos |
| 622 | 158 | Fire Extinguishers | BI01010001010000000000000515BI0100001739 | ||
| 623 | 159 | Providing ,fixing , testing and commissioning of Portable Carbon-di-oxide Gas Type Fire Extinguisher 4.5 Kgs, squeeze Grip,Controllable discharge mechanism with nozzle, bend, Hose and wall mounting bracket etc.The Can is made of Seamless Clinger and External Coating done by Spray Painting.The thickness shall not less than 4.5 mm made of Sheet metal.The Fire Extinguishers shall be ISI Approved as per IS 15683:2006.Vendor shall consider the suitable signages along with the extinguishers. | BI01010001010000000000000515BI0100001740 | 49 | Nos |
| 624 | 160 | Providing ,fixing , testing and commissioning of Portable AFFF Foam Type fire extinguisher 9 Lt Capacity, Stored Pressure Type with Pressure Gauge, hose and brackets etc .The discharge Range shall be minimum of 6 mtrs.The Internal Coating of Can shall be Epoxy Powder coating and External painted with Epoxy Polyester Powder coating .The thickness shall not less than 2mm made of Sheet metal.The Fire Extinguishers shall be ISI Approved as per IS 15683:2006.Vendor shall consider the suitable signages along with the extinguishers. | BI01010001010000000000000515BI0100001741 | 6 | Nos |
| 625 | 161 | Providing ,fixing , testing and commissioning of Portable ABC powder type fire extinguisher 6 Kg capacity containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type, fitted with Discharge hose, brackets etc., The discharge Range shall be minimum of 4 mtrs.The Internal Coating of Can shall be Epoxy Powder coating and External painted with Epoxy Polyester Powder coating.The thickness shall not less than 1.6 mm made of Sheet metal.The Fire Extinguishers shall be ISI Approved as per IS 15683:2006.Vendor shall consider the suitable signages along with the extinguishers. | BI01010001010000000000000515BI0100001742 | 84 | Nos |
| 626 | 162 | Providing ,fixing , testing and commissioning of Fire buckets round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket.The buckets hall be filled with sand. | BI01010001010000000000000515BI0100001743 | 54 | Nos |
| 627 | 163 | Providing ,fixing , testing and commissioning of Fire bucket stand fabricated by MS angles to install 2 Nos. of buckets. | BI01010001010000000000000515BI0100001744 | 27 | Nos |
| 628 | 164 | Signages | BI01010001010000000000000515BI0100001745 | ||
| 629 | 164.01 | Providing ,fixing of in position the following type of sign boards made out of 3mm thick \"Opaque\" PVC foam board with computer cut, PVC Non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners. | BI01010001010000000000000515BI0100001746 | ||
| 630 | 164.02 | A sign shall read “IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE”. The lettering shall be at least 12.5 mm block letters in red and white background. Such lettering shall be properly spaced to provide good legibility. The sign shall be at least 250 mm x 300 mm, where the diagram is also incorporated in it and 62.5 mm x 250 mm where the diagram is omitted. In the latter case, the diagram sign shall be at least 200 mm x 300 mm. The sign shall be located directly above a call-button and squarely attached to the wall or partition. The top of the sign shall not be above 2 m from the floor level. | BI01010001010000000000000515BI0100001747 | 22 | Nos |
| 631 | 164.03 | Fire exit signage at Each stairway and each elevator back shall be identified by an alphabetical letter. A sign indicating the letter of identification shall be posted and maintained at each elevator landing and on the side of the stairway door from which egress is to be made.The lettering on the sign shall be at least 75 mm high, of bold type and of contrasting colour from the background\n | BI01010001010000000000000515BI0100001748 | 22 | Nos |
| 632 | 164.04 | A sign shall be posted and maintained within each stair enclosure on every floor, indicating the number of the floors.The numerals shall be of bold type and at least 75 mm high. The numerals and background shall be in contrasting colors. The sign shall be securely attached to the stair side of the door.\n | BI01010001010000000000000515BI0100001749 | 22 | Nos |
| 633 | 164.05 | Stair Re-entry Signs sign shall be posted and maintained on each floor within each stairway and on the occupancy side of the stairway where required, indicating whether re-entry is provided into the building and the floor where such re-entry is provided.The lettering and numerals of the signs shall be at least 12.5 mm high of bold type. The lettering and background shall be of contrasting colours and the signs shall be securely attached approximately 1.5 m above the floor level.\n | BI01010001010000000000000515BI0100001750 | 22 | Nos |
| 634 | 164.06 | Fire order board should contain the following matter on 3mm thick \"Opaque\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3' x 4'.\n\n1. Alert the security at security room by actuating manual call point located at strategic locations.\n2. Evacuate the occupants by using fire exits and emergency exits only and assemble at various assembly points.\n3. If possible try to extinguish the fire by using nearest / suitable portable extinguisher or water from nearest wet riser.\n4. Be calm and do not give any room from panic, walk, do not run.\n5. If you encounter serious difficulty in evacuation, flat and try to attract attention of rescue team. | BI01010001010000000000000515BI0100001751 | 22 | Nos |
| 635 | 164.07 | Action by security/reception upon receipt of information through fire alarm or fire detectors or by using public address system.\n\n1. Alert the occupants by using public address system.\n2. Inform fire control through any one of the following phone numbers: 101 /(local numbers)\n3. Refer evacuation plan from evacuating standard people.\n4. Guide the fire force, on their arrival to the seat of fire.\n5. In case of the casualties, call ambulance by dialing number 108.\n6. Phone : -----------------------\n7. Fax : ---------------------------- | BI01010001010000000000000515BI0100001752 | 2 | Nos |
| 636 | 165 | Civil Works | BI01010001010000000000000515BI0100001753 | ||
| 637 | 165.01 | Excavation of trenches of 1500 x1000 mm for laying pipes up to 150mm dia. Including forming bottom surface to required level, refilling the trenches with selected excavated earth around the pipe in layers of 150mm thick, watering, consolidating. Quoted price inclusive of disposing off / Carting away the surplus earth out side the site to a dump yard acceptable local bodies or as directed by the site engineer with a lead of 300 mts. etc. complete. | BI01010001010000000000000515BI0100001754 | ||
| 638 | 165.02 | Excavation in all kinds of soil | BI01010001010000000000000515BI0100001755 | 480 | Cum |
| 639 | 165.03 | Construction of valve chamber with 230 mm Brick masonry wall with best quality TM bricks & CM 1:4,on a PCC 1:5;10 bed of 150 mm thcik.The wall shall be plastered internally smooth in CM 1:3, water proofing as required and externally rough plastered with sponge finish, including curing. The chamber shall be provided with M.S 8 mm thick plate fabricated top cover in leaves with necessary hinges and locking arrangement. The size of the chamber shall be 1200mm x 1200mm x1500mm in depth. | BI01010001010000000000000515BI0100001756 | 4 | Nos |
| 640 | 165.04 | Providing ,fixing , testing and commissioning of PCC (1:2:4) pedestals / supports for Under ground / above ground pipes. Quoted rate shall inclusive of excavation ( if required ), chipping / chasing, shuttering, plastering ( if required) etc. complete. | BI01010001010000000000000515BI0100001757 | 12 | Cum |
| 641 | 165.05 | Providing ,fixing , testing and commissioning of Sealing of FIRE & ELECTRICAL shafts at all floor levels by using M.S. angle Iron frame around the shaft M.S. chequered plate of 6mm thick and PCC ( 100mm thick) of 1:2:4 on the plate for whole shaft area as per drawings and engineer - in - charge. | BI01010001010000000000000515BI0100001758 | 80 | Sq.mt |
| 642 | 166 | Automatic Sprinkler System | BI01010001010000000000000515BI0100001759 | ||
| 643 | 166.01 | Providing ,fixing , testing and commissioning of GI. Pipes confirming to IS 1239 Pt - I Heavy grade up to 150 mm & 3589,6mm thick for above 150 mm dia, with painting, suitable type of supports( fabricated by angles, channels, flats etc, with painting with fasteners), anchor fasteners, bolts nuts ( Galvanized), clamps, \"U\" bolts, malleable specials such as Reducers, Tees, elbows (as per IS 1239 Pt II), flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also inclusive of civil work in walls and making them good with filler material and finished in cement mortar etc. complete.Vendor shall consider the 2 hr fire rated fire sealant material where the pipes are passing through the fire walls /compartments as per the IS code. | BI01010001010000000000000515BI0100001760 | ||
| 644 | 166.02 | 25mm nominal dia | BI01010001010000000000000515BI0100001761 | 2521 | Rmt |
| 645 | 166.03 | 32mm nominal dia | BI01010001010000000000000515BI0100001762 | 355 | Rmt |
| 646 | 166.04 | 40mm nominal dia | BI01010001010000000000000515BI0100001763 | 247 | Rmt |
| 647 | 166.05 | 50mm nominal dia | BI01010001010000000000000515BI0100001764 | 534 | Rmt |
| 648 | 166.06 | 65mm nominal dia | BI01010001010000000000000515BI0100001765 | 25 | Rmt |
| 649 | 166.07 | 80mm nominal dia | BI01010001010000000000000515BI0100001766 | 227 | Rmt |
| 650 | 166.08 | 100mm nominal dia | BI01010001010000000000000515BI0100001767 | 420 | Rmt |
| 651 | 166.09 | 150mm nominal dia | BI01010001010000000000000515BI0100001768 | 426 | Rmt |
| 652 | 167 | Providing ,fixing , testing and commissioning of PN 16 CI butterfly valves as per BS 5155 slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. | BI01010001010000000000000515BI0100001769 | ||
| 653 | 167.01 | 50mm nominal dia | BI01010001010000000000000515BI0100001770 | 12 | Nos |
| 654 | 167.02 | 80mm nominal dia | BI01010001010000000000000515BI0100001771 | 2 | Nos |
| 655 | 167.03 | 100mm nominal dia | BI01010001010000000000000515BI0100001772 | 6 | Nos |
| 656 | 167.04 | 150mm nominal dia | BI01010001010000000000000515BI0100001773 | 20 | Nos |
| 657 | 168 | Providing ,fixing , testing and commissioning of standard response type Sprinkler quartzoid bulb type with 15mm screwed end connection of 79 deg. C. temperature rating,K factor of 80 and sprinklers shall be UL Listed. | BI01010001010000000000000515BI0100001774 | ||
| 658 | 168.01 | Pendent type - Quick response | BI01010001010000000000000515BI0100001775 | 1424 | Nos |
| 659 | 168.02 | Upright type - Quick response | BI01010001010000000000000515BI0100001776 | 445 | Nos |
| 660 | 169 | Providing ,fixing , testing and commissioning of flow switch on sprinkler distribution header on each floor and shall be connected to fire alarm panel through cable. | BI01010001010000000000000515BI0100001777 | 12 | Nos |
| 661 | 170 | Providing ,fixing , testing and commissioning of GI Pipes confirming to IS 1239 Pt - I Heavy grade up to 150 mm & 3589,6mm thick for above 150 mm dia, with suitable type of supports, malleable specials such as Reducers,Tees, elbows(as per IS 1239 Pt II), flanges. Including cutting, Welding as per drawings. The rate quoted should be included with anticorrosive treatment with 4 mm thick polymer corrosion resistant tape as per IS 10221, overlap shall be maintained at 15mm minimum. | BI01010001010000000000000515BI0100001778 | ||
| 662 | 170.01 | 150mm nominal dia | BI01010001010000000000000515BI0100001779 | 24 | Rmt |
| 663 | 171 | Providing ,fixing , testing and commissioning of approved make 20mm dia. With automatic air release valve with unions and ball valve etc. complete. | BI01010001010000000000000515BI0100001780 | 2 | Nos |
| 664 | 172 | Providing ,fixing , testing and commissioning of Stainless steel corrugated flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be UL Listed & FM approved, 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. | BI01010001010000000000000515BI0100001781 | 445 | Nos |
| 665 | 173 | Providing ,fixing , testing and commissioning of Rosette plate and shall be fabricated by SS 304 plate of 2mm thick and sample, as approved by architects / clients. | BI01010001010000000000000515BI0100001782 | 445 | Nos |
| 666 | 174 | Providing ,fixing , testing and commissioning of 150mm dia.hydraulically operated Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, ball valves, check valves, strainers etc. complete. Alarm valve shall be UL Listed. | BI01010001010000000000000515BI0100001783 | 2 | Nos |
| 667 | 175 | Addressable Fire Detection & Alarm System | BI01010001010000000000000515BI0100001784 | ||
| 668 | 176 | Providing ,fixing , testing and commissioning of Analogue addressable Fire Alarm Control panel WITH battery back up for 48 hours normal operation and 15 minutes alarm operation. The control panel, battery charger etc, power supply units shall be UL listed / EN54 approved. The panel shall be 5 loop capacity and capable to expand up to 10 loops. The panel shall have minimum of 164 character LCD display and RS 232 & 485 for networking. Also panel shall be LAN compatible with bacnett / modbus software or proprietary protocol, network adaptor etc, complete.Vendor shall consider the required power supply unit for hooters and suitable signages along with the panel.MAKE-EDWARD,NOTIFIER,HONEYWELL,BOSCH | BI01010001010000000000000515BI0100001785 | 1 | Nos |
| 669 | 177 | Providing ,fixing , testing and commissioning of graphic software for programming( mapping) the Fire detection and alarm system through FACP / Lap top. The software shall consisting with facility like Upload / down load of information's to FACP, Graphics compatible to AutoCAD, Detectors information with change in address / sensitivity etc as required as per the technical specification. | BI01010001010000000000000515BI0100001786 | 1 | Nos |
| 670 | 178 | Providing ,fixing , testing and commissioning of Addressable type beam detector including , transmitter and reviver . The coverage distance shall no less than 20x100 mt . Vendor shall consider necessary supporting accessocies and required modules and other accessories as required and Detectors shall be UL listed/EN 54 Approved | BI01010001010000000000000515BI0100001787 | 5 | Nos |
| 671 | 179 | Providing ,fixing , testing and commissioning of Addressable Intelligent multisensor type with standard base, Junction box and other accessories as required and Detectors shall be UL listed / EN 54 Approved | BI01010001010000000000000515BI0100001788 | 248 | Nos |
| 672 | 180 | Providing ,fixing , testing and commissioning of Addressable Intelligent ROR heat detectors with standard base, Junction box and other accessories as required and Detectors shall be UL listed /EN 54 Approved | BI01010001010000000000000515BI0100001789 | 24 | Nos |
| 673 | 181 | Providing ,fixing , testing and commissioning of Response indicator for all detectors located above false ceiling and below false flooring areas. | BI01010001010000000000000515BI0100001790 | ||
| 674 | 182 | Providing ,fixing , testing and commissioning of Hooter cum Strobe rated at 90 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication.The Hooter cum Strobe shall be as per technical specification and module shall be UL listed/EN 54 approved.Vendor shall consider the suitable signages,control modules & Power supply units along with the Hooters. | BI01010001010000000000000515BI0100001791 | 36 | Nos |
| 675 | 183 | Providing ,fixing , testing and commissioning of Intelligent Manual pull station having an integrally mounted addressable module that monitors and reports contact status.The MCP shall be as per technical specification and module shall be of UL listed/EN54 approved .Vendor shall consider the suitable signages along with the manual call point. | BI01010001010000000000000515BI0100001792 | 36 | Nos |
| 676 | 184 | Providing ,fixing , testing and commissioning of Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected and modules shall be UL listed /EN 54 approved . | BI01010001010000000000000515BI0100001793 | 13 | Nos |
| 677 | 185 | Providing ,fixing , testing and commissioning of Addressable Intelligent Duct sensor detector with multiple sensitivity levels, programmable for timed automatic sensitivity ( adjustable at site) selection with base and fixing accessories as required and Detectors shall be UL listed /EN54 approved . | BI01010001010000000000000515BI0100001794 | 16 | Nos |
| 678 | 186 | Providing ,fixing , testing and commissioning of Monitor modules to indicate status of flow switches, supervision of pumps etc.The Addressable monitor module shall be as per technical specification and module shall be UL listed and FM approved . | BI01010001010000000000000515BI0100001795 | 30 | Nos |
| 679 | 187 | Providing ,fixing , testing and commissioning of Control relay module shall be capable of providing tripping of Lift machines .The Addressable control relay module shall be as per technical specification and module shall be of UL listed /EN approved . | BI01010001010000000000000515BI0100001796 | 50 | Nos |
| 680 | 188 | Providing ,fixing , testing and commissioning of Control module .The Addressable control module shall be as per technical specification and module shall be of UL listed /EN approved . | BI01010001010000000000000515BI0100001797 | 15 | Nos |
| 681 | 189 | Providing ,laying , testing and commissioning of 2C x 1.5 sq.mm twisted pair armoured copper cable confirming to IS standards and specifications. The quoted rate shall inclusive of suitable saddles, hardware etc, complete - For fire alarm system. | BI01010001010000000000000515BI0100001798 | 5120 | Rmt |
| 682 | 190 | Providing ,laying , testing and commissioning of 20 mm dia.MS flexible conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc. | BI01010001010000000000000515BI0100001799 | 298 | Rmt |
| 683 | 191 | Providing ,fixing , testing and commissioning of PVC FRLS as per IS standards conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc. | BI01010001010000000000000515BI0100001800 | ||
| 684 | 191.01 | 20 mm dia | BI01010001010000000000000515BI0100001801 | 10 | Rmt |
| 685 | 191.02 | 25 mm dia | BI01010001010000000000000515BI0100001802 | 10 | Rmt |
| 686 | 191.03 | 32 mm dia | BI01010001010000000000000515BI0100001803 | 10 | Rmt |
| 687 | 192 | Supplying and fixing of perforated G.I.sheet cable tray with necessary angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray is 100 X 50 X 1.6 mm - for beam detector | BI01010001010000000000000515BI0100001804 | 250 | Rmt |
| 688 | 193 | Two way Talk Back System | BI01010001010000000000000515BI0100001805 | ||
| 689 | 194 | Providing ,fixing , testing and commissioning of 30 Zone Talk back controller made of CRCA sheet housing and rack as required. The Controller shall be micro processor based priority module , mixing amplifier, all call / call back facility with key pad, power supply unit & goose neck micro phone etc complete as per the technical specifications. The Console shall have minimum of 8 hrs battery back up and it should also work on AC single phase power. The Controller shall be as per the technical specifications. | BI01010001010000000000000515BI0100001806 | 1 | Nos |
| 690 | 195 | Providing ,fixing , testing and commissioning of B-class Amplifier of 480W RMS out put in rack, including necessary control wires, jocks etc. complete as per the technical specifications. | BI01010001010000000000000515BI0100001807 | 1 | Nos |
| 691 | 196 | Providing ,fixing , testing and commissioning of 6W two way talk back Speakers WITH talk back switch made of CRCA sheet fabricated and of wall mounted type with required junction boxes and complete fixing accessories. | BI01010001010000000000000515BI0100001808 | 21 | Nos |
| 692 | 197 | Providing ,laying , testing and commissioning of 2C x 1.5 sq.mm copper wires of FRLS and sheath with confirming to IS standards and specifications. The quoted rate shall inclusive of suitable saddles, hardware etc, complete | BI01010001010000000000000515BI0100001809 | 2240 | Rmt |
| 693 | 198 | Providing ,fixing , testing and commissioning of PVC FRLS as per IS standards conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc. | BI01010001010000000000000515BI0100001810 | ||
| 694 | 198.01 | 20 mm dia | BI01010001010000000000000515BI0100001811 | 10 | Rmt |
| 695 | 198.02 | 25 mm dia | BI01010001010000000000000515BI0100001812 | 10 | Rmt |
| 696 | 198.03 | 32 mm dia | BI01010001010000000000000515BI0100001813 | 10 | Rmt |
| 697 | 199 | Supplying and fixing of perforated G.I.sheet cable tray with necessary angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray is 40mm x 200mm x 1.6 mm thick. | BI01010001010000000000000515BI0100001814 | 60 | Rmt |
| 698 | 200 | Digital Public Address System | BI01010001010000000000000515BI0100001815 | ||
| 699 | 201 | Network Controller | BI01010001010000000000000515BI0100001816 | 1 | Nos |
| 700 | 201.01 | \nProviding ,fixing , testing and commissioning of Digital Public Address and Emergency Sound System Controller certified to International standards of Emergency Sound System EN 54 (IEC 60849) with following features :\n- Completely digital audio and control data transmission.\n- Fibre/ CAT 5 connection for digital network and connection to amplifiers and other interface.\n- In-built Digital Message storage with min 1gB capacity for 3 hrs of audio messages.\n- PC based programmable inbuilt Web server.\"\n- External Alarm Inputs /Programmable auto relay of pre recorded messages/Alarm tones/messages\n- Automatic Fault Diagnostic and reporting at central location- From Mic Capsule in call station uptil amplifiers and loudspeaker circuits.The system shall be able to make emergency calls (all calls) even if the network controller has failed\n- Freely programmable 200 level of priority/ around 50 Different chime/alarm tones, freely programmable/modifiable zone assignment and routing \n- Upgradation requires no changes in control equipment, - provision for more 248 zones from single controller - All Programmable through software. -Inbuilt message scheduler to schedule the broadcast of pre-recorded mesages. - 2 x 16-character LCD display and a rotary control to navigate through the menu. - 28 simultaneous audio channels available for audio transportation between any inputs and outputs - The network controller shall have 4 analogue audio line outputs. - Sampling Frequency of controller shall be equal or more then 44.1 khz. | BI01010001010000000000000515BI0100001817 | ||
| 701 | 201.02 | Approved Makes : Bosch/TOA/IC Audio/HONEYWELL | BI01010001010000000000000515BI0100001818 | ||
| 702 | 202 | Remote Call Station | BI01010001010000000000000515BI0100001819 | 1 | Nos |
| 703 | 202.01 | Providing ,fixing , testing and commissioning of EN 54 certified Remote call station with interface unit is to be used for calling purpose and other applications with following features: - Connects to call station interface via CAT-5 cable - Up to 1 km from digital public address optical network - Built-in limiter - 2 supervised control inputs | BI01010001010000000000000515BI0100001820 | ||
| 704 | 202.02 | Approved Makes : Bosch/Heinrich/IC Audio | BI01010001010000000000000515BI0100001821 | ||
| 705 | 203 | Call Station Keypad | BI01010001010000000000000515BI0100001822 | 1 | Nos |
| 706 | 203.01 | Providing ,fixing , testing and commissioning of EN 54 certified Digital call station extension keypad with 8 freely programmable keys with the following features- - compliant to IEC60849 - keys can be programme recall of selection, live speech call, cancel selection, BGM off, BGM volume control, programmable key for any action - Select resources: BGM selection, pre-recorded message selection, attention and alarm tone selection - 2 color LEDs on Each key at the call station keypad - a label slot for indicating the name of the action assigned to that particular key | BI01010001010000000000000515BI0100001823 | ||
| 707 | 203.02 | Digital Power Amplifier 500 W | BI01010001010000000000000515BI0100001824 | 2 | Nos |
| 708 | 204 | Providing ,fixing , testing and commissioning of of EN 54 certified Digital Class-D Amplifier 500W each with single/dual channels as per the design/tender requirement. The amplifiers should have digital audio interface connection to network controller via Fiber optics/CAT 5 . Features- Inbuilt Digital Audio signal processing like 3 section parametric equalisation - Built in or external min 1 channel Automatic Volume control circuitry for noise sensing, Front LCD Character Display for status information. - Compliance to Standards for Emergency sound System IEC 60849 - Inbuilt Amplifier Monitoring eg for Short Circuit etc. Inbuilt Output monitoring - Loudspeaker line monioring for every zone/speaker circuit - Automatic Amplifier Changeover to hot standby amplifier in case of failure of working amplifier with internal relays. - output voltage between 100V, 70V or 50V by changing jumpers -Separate amplifiers or separate channels of amplifiers for every zone should be considered - digital signal processing for audio - 2 auxiliary audio inputs with microphone/line level selection - 8 x control inputs are freely programmable - 1 x control outputs shall be freely programmable and can be programmed for faults and calls - designed for redundant network wiring - 3 sections of parametric equalization and 2 sections of shelving equalization and audio delay | BI01010001010000000000000515BI0100001825 | ||
| 709 | 204.01 | Approved Makes : Bosch/TOA/IC Audio | BI01010001010000000000000515BI0100001826 | ||
| 710 | 204.02 | 6W Metal grille ceiling speaker with fire dome | BI01010001010000000000000515BI0100001827 | 90 | Nos |
| 711 | 205 | Providing ,fixing , testing and commissioning of 6W ceiling mount EN 54 certified speaker with suitable fire dome having the following specification:\n- Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W\n- Effective frequency range(-10 dB) :90 Hz to 20KHz\n- SPL at rated power (1Khz at 1 m) 98 dB\n- Opening Angle 1 KHz / 4 KHz (-6 dB): 180/50 Diameter 216 mm (8.5 in) Maximum depth 90 mm (3.54 in) | BI01010001010000000000000515BI0100001828 | ||
| 712 | 205.01 | Approved Makes : Bosch/Heinrich/IC Audio | BI01010001010000000000000515BI0100001829 | ||
| 713 | 205.02 | 6W wall mount speaker | BI01010001010000000000000515BI0100001830 | 4 | Nos |
| 714 | 206 | Providing ,fixing , testing and commissioning of 6W wall mount EN 54 certified speaker with suitable fire dome having the following specification:\n- Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W\n- Effective frequency range(-10 dB) :90 Hz to 20KHz\n- SPL at rated power (1Khz at 1 m) 98 dB\n- Opening Angle 1 KHz / 4 KHz (-6 dB): 180/50 | BI01010001010000000000000515BI0100001831 | ||
| 715 | 206.01 | Approved Makes : Bosch/Heinrich/IC Audio | BI01010001010000000000000515BI0100001832 | ||
| 716 | 207 | Providing ,fixing , testing and commissioning of Network cable of 0.5 Mtr | BI01010001010000000000000515BI0100001833 | 2 | Nos |
| 717 | 208 | Providing ,fixing , testing and commissioning of CD/DVD Player -Professional grade | BI01010001010000000000000515BI0100001834 | 1 | Nos |
| 718 | 209 | Providing ,laying , testing and commissioning of 2C x 1.5 sq.mm twisted pair armoured copper cable confirming to IS standards and specifications. The quoted rate shall inclusive of suitable saddles, hardware etc, complete | BI01010001010000000000000515BI0100001835 | 2500 | mts |
| 719 | 210 | Providing ,fixing , testing and commissioning of 19 \"Equipment Rack,18 U Made of MS for housing of all above equipment , front lockable glass door, Fan tray fro colling, Caster wheel base , Main Panel with Spike Buster, Indivdual FUSE power supply unit, including all internal wiring/ interconnection as required | BI01010001010000000000000515BI0100001836 | 1 | Nos |
| 720 | 211 | Providing ,fixing , testing and commissioning of Cat 6 cable for the complete interface. | BI01010001010000000000000515BI0100001837 | 1 | Lot |
| 721 | 212 | Supplying and fixing of perforated G.I.sheet cable tray with necessary angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray is 100 X 50 X 1.6 mm | BI01010001010000000000000515BI0100001838 | 30 | Rmt |
| 722 | 213 | ELECTRICAL WORKS | BI01010001010000000000000515BI0100001839 | ||
| 723 | 214 | PART - A : HT POWER DISTRIBUTION SYSTEM | BI01010001010000000000000515BI0100001840 | ||
| 724 | 215 | 11KV HT RMU: (OUTDOOR TYPE) | BI01010001010000000000000515BI0100001841 | ||
| 725 | 215.01 | Design, Manufacturing, Supply, Installation,Testing and commisioning of Outdoor type 33KV HT Ring main unit (RMU) with Full DAS as per the CESU requirements comprising of the following: \nIncomers : 2 Nos. 11KV, 630A, HT Load Break Switch with all standard accessories.\nOutgoings : 1 No. 11KV, 630A, 26.3KA, Vacuum Circuit Breaker, Horizontal Drawout, Horizontally Isolated with all standard accessories.\nComplete with CT and PT, Indication Lamps, Aluminium Busbars, Earthing, etc., The panel shall be erected using necessary accessories all complete as required by CESU and properly grouted to the plinth with all accesories required for grouting. | BI01010001010000000000000515BI0100001842 | 1 | No. |
| 726 | 216 | 11KV HT METERING CUBICLE: (Outdoor type) | BI01010001010000000000000515BI0100001843 | ||
| 727 | 216.01 | Supply, erection, testing and commissioning of 11kV Outdoor type metering cubicle (from CESU authorized fabricator) with a Trivector meter as per the requirement of EB norms, get it caliberated by MRT Division of EB, commission at site in the presence of EB/MRT Division personnel. The quoted rate shall be inclusive of CTS, PTs, Bus Bars, etc., | BI01010001010000000000000515BI0100001844 | 1 | No. |
| 728 | 217 | 11KV HT CABLING & TERMINATIONS: | BI01010001010000000000000515BI0100001845 | ||
| 729 | 217.01 | Supply, laying, testing & commissioning of 11KV, 3core 240 Sq.mm. Earthed-Stranded Alumimum conductor XLPE insulated, Armoured Cable in readymade Trench / Excavation / tray | BI01010001010000000000000515BI0100001846 | 150 | Mtr |
| 730 | 218 | Supply and making indoor / outdoor cable end terminations with heat shrinkable jointing kit complete with all accessories suitable for following size of 3core, XLPE aluminium conductor cable of 11 KV grade as required(KEI / POLYCAB / RR CABLE/HAVELLS) | BI01010001010000000000000515BI0100001847 | ||
| 731 | 218.01 | 11KV, 3core 240Sq.mm - INDOOR | BI01010001010000000000000515BI0100001848 | 6 | Nos. |
| 732 | 218.02 | 11KV, 3core 240Sq.mm - OUTDOOR | BI01010001010000000000000515BI0100001849 | ||
| 733 | 219 | 1000KVA, 11KV/433V, TRANSFORMER | BI01010001010000000000000515BI0100001850 | ||
| 734 | 219.01 | Supply, erection, testing and commissioning 11KV/0.433KV, 1000KVA, Outdoor Duty, Oil cooled type, Two winding, low loss and low noise design, Three phase, 50Hz, ONAN cooled, vector group Dyn11 & Percentage of impedance 5% as per IS 2026 ( Part-1)with no negative tolerance, having cable box on HV side and LV side with extended bus bar supprot for cable connections with all accessories as required. Load losses shall be as per IS 2026(part-1) The losses figures as indicated while submitting GTP, shall be maximum and shall not have any positive tolerance. The transformer OLTC shall have the tapings of +5% -15% in steps of 2.5%.(OTPL/ALFA/OEU) | BI01010001010000000000000515BI0100001851 | 1 | No |
| 735 | 220 | HT YARD FENCING: | BI01010001010000000000000515BI0100001852 | ||
| 736 | 220.01 | Supply and erection of 11KV HT EB & Transformer yard fencing using 10gauge chain link / Wire Mesh frames made out of 50 x 50 x 6 mm angle iron outer frame work and chain link / Wire mesh of 10 Gauge, 75mm ISMC verticals 1800mm above formed level. Height of the fencing is 1800mm from the FFL. The cost is inclusive of GATES for CESU and CLIENT side | BI01010001010000000000000515BI0100001853 | 56 | Mtr |
| 737 | 221 | Supply and laying of 40mm size aggregate ( granite jally ) for a height of 150 mm and 75 mm riversand cushioning below the above mentioned 40 mm aggregate at with in the tr. yard as per the norms of CEIG. | BI01010001010000000000000515BI0100001854 | 200 | Sq.M |
| 738 | 222 | EARTHING ELECTRODES & EARTH FLATS | BI01010001010000000000000515BI0100001855 | ||
| 739 | 223 | Supply, erection and testing of GI Plate earth electrode as per IS 3043 standards complete with 3 mtrs long, 40mm dia. GI pipe, 600 x 600 x 6mm size GI plate and 2 run of 50 x 6mm GI flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. (For HT RMU, MC, VCB and Transformer earthing) | BI01010001010000000000000515BI0100001856 | 2 | Nos |
| 740 | 224 | Supply, erection and testing of Copper Plate earth electrode as per IS 3043 standards complete with 3 mtrs long, 40mm dia GI pipe, 600 x 600 x 3.15mm size Copper plate and 2 run of 50 x 6mm Copper flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. \n(TRANSFORMER NEUTRAL) | BI01010001010000000000000515BI0100001857 | 2 | Nos |
| 741 | 224.01 | Supply and laying of 50 x 6 mm Copper flat - Transformer Neutral earthing | BI01010001010000000000000515BI0100001858 | 20 | Mtr |
| 742 | 224.02 | Supply and laying of 50 x 6 mm GI flat | BI01010001010000000000000515BI0100001859 | 50 | Mtr |
| 743 | 224.03 | Supply and laying of 25 x 3 mm Copper flat (LA Earth & Others) | BI01010001010000000000000515BI0100001860 | 45 | Mtr |
| 744 | 224.04 | Supply and laying of 8 gauge bare copper wire | BI01010001010000000000000515BI0100001861 | 150 | Mtr |
| 745 | 225 | STATUTORY APPROVALS (CEIG & Local Authority) | BI01010001010000000000000515BI0100001862 | ||
| 746 | 226 | Liasoning charges towards preparation of 11KV HT Application for --KVA of Maximum Demand and submitting CESU, co-ordinate with EB officials, checking load feasibility, getting Load sanction approval, submitting the CEIG's safety certificate to EB officials to energise and commissioning HT Power connection at your premises. All the official charges will be remitted by the client against the documents. | BI01010001010000000000000515BI0100001863 | 1 | Job |
| 747 | 227 | Liasoning charges towards Preparation of Electrical drawings (SLD, Power Layout, HT Yard Layout, etc.,) in necessary formats and submitting for approval to CEIG follow up and arranging approval of drawings. Preparation and submission of works completion report in neccessary formats to CEIG and arranging inspection at site, obtaining Safety certificate and HT equipments test certificate approvals from the Electrical Inspectorate for the electricals installations. The Rate shall be including preparation and submission of As-built drawings of entire installation of the works executed need to be submitted in the A1 size as required in 2 Sets of hard copy and two set of soft copy in CD. All the official charges will be remitted by the client against the documents. | BI01010001010000000000000515BI0100001864 | 1 | Job |
| 748 | 228 | Miscellenous Items: | BI01010001010000000000000515BI0100001865 | ||
| 749 | 229 | Supply and installation of HT/LT Danger board as required by the CEIG authorities. | BI01010001010000000000000515BI0100001866 | 20 | Nos |
| 750 | 230 | Supply and erection of fire extinguisher Co2 4.5 Kg. confirm to TAC norms. | BI01010001010000000000000515BI0100001867 | 4 | Nos |
| 751 | 231 | Supply of Hand gloves of 11KV grade. | BI01010001010000000000000515BI0100001868 | 1 | Pair |
| 752 | 232 | Supply and fixing of Shock treatment chart / First Aid Chart | BI01010001010000000000000515BI0100001869 | 2 | Nos |
| 753 | 233 | Supply and fixing approved Single line diagram, etc., of A1 size with frame | BI01010001010000000000000515BI0100001870 | 2 | Nos |
| 754 | 234 | Supply and laying of 2.5mm thick 1000mm wide chequered rubber mat with ISI mark suitable for 11KV installation . | BI01010001010000000000000515BI0100001871 | 8 | Mtr |
| 755 | 235 | Supply and laying of 2mm thick 1000mm wide chequered rubber mat with ISI mark suitable for 415V installation . | BI01010001010000000000000515BI0100001872 | 40 | Mtr |
| 756 | 236 | Supply and providing St.John make first aid box 18SWG MS sheet duly painted as approved by Indian red cross soceity complete with all first aid medicines. | BI01010001010000000000000515BI0100001873 | 2 | Set |
| 757 | 237 | Supply and fixing of fire buckets with round bottom, each set comprising 2Nos. fire buckets of 9Kg capacity, MS pedestal stand for holding of fire buckets, painted with Red oil paint & letter FIRE on each bucket and filling with sand | BI01010001010000000000000515BI0100001874 | 3 | Set |
| 758 | 238 | Supply and fixing of HT/LT cable route indicator (cast iron) made out of MS flat and angle iron | BI01010001010000000000000515BI0100001875 | 10 | Nos |
| 759 | 239 | Earth excavation of trench of Size 1000mm(W)X1000mm(D) in hard soil including labour charges for excavation and refilling charges and making in the same shape as earlier including all labour charges etc.,complete | BI01010001010000000000000515BI0100001876 | 120 | Rmtr |
| 760 | 240 | Earth excavation of trench of Size 500mm(W)X1000mm(D) in hard soil including labour charges for excavation and refilling charges and making in the same shape as earlier including all labour charges etc.,complete | BI01010001010000000000000515BI0100001877 | 50 | Rmtr |
| 761 | 241 | Providing and laying of 1200mm (L) x 1200mm (W) x 1000mm (D) Inspection Chamber with pre cast Cover and all necessary accessories as required | BI01010001010000000000000515BI0100001878 | 12 | Nos. |
| 762 | 242 | Providing and laying of 600mm (L) x 600mm (W) x 1000mm (D) Inspection Chamber with pre cast Cover and all necessary accessories as required | BI01010001010000000000000515BI0100001879 | 5 | Nos. |
| 763 | 243 | Providing and laying of RCC Hume pipe(NP2) for Communication cables. Cost to include RCC collar and necessary civil works like jointing of hume pipes with mortar as required.(Excavation & Back filling cost not included) - For Communication & Earthing | BI01010001010000000000000515BI0100001880 | ||
| 764 | 243.01 | 300 mm Dia RCC Hume pipe | BI01010001010000000000000515BI0100001881 | 50 | Rmtr |
| 765 | 243.02 | 150 mm Dia RCC Hume pipe | BI01010001010000000000000515BI0100001882 | 50 | Rmtr |
| 766 | 244 | PART - B : LT PANEL BOARDS: | BI01010001010000000000000515BI0100001883 | ||
| 767 | 244.01 | Design, Fabrication, Supply, erection, testing and commissioning of LT Panel boards of cubicle floor mounting type made out of 14/16 Gauge CRCA sheet steel construction dust and vermin proof for indoor use degree of protection is IP52, extensible on both sides, rated for 433V, 3phase 50 Hz AC supply 4 wire system. The painting of the complete system shall be by powder coating (The colour as per the choice of the client) or as per the requirement of the employer.\nAll the panel boards should be with suitable cable chamber for outgoing cables with suitable removal type gland plates. All switch boards shall be complete with double Earthing arrangements in entire length of the panel and cable chambers using sutiable rating of aluminium flats, feeder identifications, etc., as per Standards(Refer SLD Drawing for incoming & Outgoing Feeder details) | BI01010001010000000000000515BI0100001884 | ||
| 768 | 244.02 | i) All ACB feeders shall be draw out type, MCCB feeders shall be fixed type \nii) The microprocessor releases type MCCB shall be provided for above 250A\niii) The thermal magnetic releases type MCCB shall be provided for upto 250A\niv) All breakers should have minimum kA rating as mentioned in BOQ. On non availability of specified breaker, immediate higher rating breaker to be provided.\nv) All live parts should be shrouded by transparent polycarbonate sheet \nvi) Current density of aluminium busbar - 0.8A /Sq. mm | BI01010001010000000000000515BI0100001885 | ||
| 769 | 244.03 | LT KIOSK | BI01010001010000000000000515BI0100001886 | 1 | Nos. |
| 770 | 244.04 | Incomer : | BI01010001010000000000000515BI0100001887 | ||
| 771 | 244.05 | 1 No. 1600Amps, 4Pole, 65KA, Electrical draw out type Air Circuit Breaker (ACB) complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001888 | ||
| 772 | 244.06 | Metering (EB): | BI01010001010000000000000515BI0100001889 | ||
| 773 | 244.07 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n | BI01010001010000000000000515BI0100001890 | ||
| 774 | 244.08 | OUTGOINGS | BI01010001010000000000000515BI0100001891 | ||
| 775 | 244.09 | 1Nos. 1600Amps, 4P, 50KA, MCCB with microprocessor based OL,SC releases (Main Electrical Panel) | BI01010001010000000000000515BI0100001892 | ||
| 776 | 244.1 | 1Nos. 1600Amps, 4P, 50KA, MCCB with microprocessor based OL,SC releases (Spare) | BI01010001010000000000000515BI0100001893 | ||
| 777 | 244.11 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases.\nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. \nc) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001894 | ||
| 778 | 245 | DG SYNC MAIN PANEL | BI01010001010000000000000515BI0100001895 | 1 | Nos. |
| 779 | 245.01 | Incomer - 1 : (DG-1 - 500KVA) | BI01010001010000000000000515BI0100001896 | ||
| 780 | 245.02 | 1 No. 800Amps, TP+NL, 50KA, Electrical draw out type Air Circuit Breaker (ACB) complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001897 | ||
| 781 | 245.03 | Metering (EB): | BI01010001010000000000000515BI0100001898 | ||
| 782 | 245.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 No. Digital Mult-Function Meter with RS 485 port \n1 Set of Current transformers of ratio 800/5A,class 1 for metering\n1 No. of Current transformer of ratio 800/5A,class5P10 for protection\n1.No of Combined Under/Over Voltage relay 1.No of Master trip relay 1.No of REF relay 1.No ofDC supply failure relay\n1 No. Under voltage / Over voltage relay, Single Phasing Preventer \n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001899 | ||
| 783 | 245.05 | Incomer - 2 : (DG-2 - 500KVA) | BI01010001010000000000000515BI0100001900 | ||
| 784 | 245.06 | 1 No. 800Amps, TP+NL, 50KA, Electrical draw out type Air Circuit Breaker (ACB) complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001901 | ||
| 785 | 245.07 | Metering (EB): | BI01010001010000000000000515BI0100001902 | ||
| 786 | 245.08 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 No. Digital Mult-Function Meter with RS 485 port \n1 Set of Current transformers of ratio 800/5A,class 1 for metering\n1 No. of Current transformer of ratio 800/5A,class5P10 for protection\n1.No of Combined Under/Over Voltage relay 1.No of Master trip relay 1.No of REF relay 1.No ofDC supply failure relay\n1 No. Under voltage / Over voltage relay, Single Phasing Preventer \n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001903 | ||
| 787 | 245.09 | Bus Coupler: | BI01010001010000000000000515BI0100001904 | ||
| 788 | 245.1 | 1 No. 1600Amps, 4Pole, 50KA, Electrical draw out type Air Circuit Breaker (ACB) complete with microprocessor based OL, SC, releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001905 | ||
| 789 | 245.11 | Control and Annunciation: | BI01010001010000000000000515BI0100001906 | ||
| 790 | 245.12 | 2.No of 12 Window Annunciator | BI01010001010000000000000515BI0100001907 | ||
| 791 | 245.13 | 2.No of Hooter | BI01010001010000000000000515BI0100001908 | ||
| 792 | 245.14 | 2.No of Hour Meter | BI01010001010000000000000515BI0100001909 | ||
| 793 | 245.15 | 2.No of Counter | BI01010001010000000000000515BI0100001910 | ||
| 794 | 245.16 | 2.No of Engine Control Switch | BI01010001010000000000000515BI0100001911 | ||
| 795 | 245.17 | 2.No of Hooter | BI01010001010000000000000515BI0100001912 | ||
| 796 | 245.18 | 2.No of Battery Charging Unit | BI01010001010000000000000515BI0100001913 | ||
| 797 | 245.19 | 2.No of DC Ammeter ( Battery ) | BI01010001010000000000000515BI0100001914 | ||
| 798 | 245.2 | 2.No of DC Voltmeter ( Battery ) | BI01010001010000000000000515BI0100001915 | ||
| 799 | 245.21 | 2.No of Pushbuttons | BI01010001010000000000000515BI0100001916 | ||
| 800 | 245.22 | 2.No of EPB | BI01010001010000000000000515BI0100001917 | ||
| 801 | 245.23 | 1. No of PLC for Load management with Aoto Start,Stop and Synchronizing (Workstation - PC Not in our scope) | BI01010001010000000000000515BI0100001918 | ||
| 802 | 245.24 | INTERLOCKING | BI01010001010000000000000515BI0100001919 | ||
| 803 | 245.25 | Electro - Mechanical interlocking arrangements provided between the EB Incomer-1, Bus coupler, DG Incomer - 1 | BI01010001010000000000000515BI0100001920 | ||
| 804 | 245.26 | OUTGOINGS | BI01010001010000000000000515BI0100001921 | ||
| 805 | 245.27 | 1Nos. 1600Amps, 4P, 50KA, ACB with microprocessor based OL,SC releases (Main LT Panel ) (L & T / SIEMENS / SCHNEIDER / Legrand) | BI01010001010000000000000515BI0100001922 | ||
| 806 | 245.28 | 1Nos. 1600Amps, 4P, 50KA, ACB with microprocessor based OL,SC releases (Spare ) | BI01010001010000000000000515BI0100001923 | ||
| 807 | 245.29 | 1Nos. 400Amps, 4P, 36KA, ACB with microprocessor based OL,SC releases (Fire Panel ) | BI01010001010000000000000515BI0100001924 | ||
| 808 | 245.3 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases.\nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. \nc) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001925 | ||
| 809 | 246 | MAIN ELEC PANEL | BI01010001010000000000000515BI0100001926 | 1 | Nos. |
| 810 | 246.01 | Incomer - 1 : (EB Supply) | BI01010001010000000000000515BI0100001927 | ||
| 811 | 246.02 | 1 No. 1600Amps, 4Pole, 65KA, Electrical draw out type Air Circuit Breaker (ACB) complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001928 | ||
| 812 | 246.03 | Metering (EB): | BI01010001010000000000000515BI0100001929 | ||
| 813 | 246.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 No. Digital Mult-Function Meter with RS 485 port \n1 Set of Current transformers of ratio 1600/5A,class 1 for metering\n1 No. of Current transformer of ratio 1600/5A,class5P10 for protection\n1 No. of current transformer of ratio 600/5A, for APFC\n1 No. Under voltage / Over voltage relay, Single Phasing Preventer\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001930 | ||
| 814 | 246.05 | 1 No. 1600Amps, 4Pole, 65KA, Electrical draw out type Air Circuit Breaker (ACB) complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001931 | ||
| 815 | 246.06 | Metering (EB): | BI01010001010000000000000515BI0100001932 | ||
| 816 | 246.07 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 No. Digital Mult-Function Meter with RS 485 port \n1 Set of Current transformers of ratio 1600/5A,class 1 for metering\n1 No. of Current transformer of ratio 1600/5A,class5P10 for protection\n1 No. Under voltage / Over voltage relay, Single Phasing Preventer\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001933 | ||
| 817 | 246.08 | Bus Coupler: | BI01010001010000000000000515BI0100001934 | ||
| 818 | 246.09 | 1 No. 2000Amps, 4Pole, 50KA, Electrical draw out type Air Circuit Breaker (ACB) complete with microprocessor based OL, SC, releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001935 | ||
| 819 | 246.1 | INTERLOCKING | BI01010001010000000000000515BI0100001936 | ||
| 820 | 246.11 | Electro - Mechanical interlocking arrangements provided between the EB Incomer, Bus coupler, DG Incomer | BI01010001010000000000000515BI0100001937 | ||
| 821 | 246.12 | OUTGOINGS | BI01010001010000000000000515BI0100001938 | ||
| 822 | 246.13 | 2Nos. 630Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Building Main Panel and APFCR Panel, ) | BI01010001010000000000000515BI0100001939 | ||
| 823 | 246.14 | 1Nos. 400Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Fire panel ) | BI01010001010000000000000515BI0100001940 | ||
| 824 | 246.15 | 1Nos. 250Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Utility Panel) | BI01010001010000000000000515BI0100001941 | ||
| 825 | 246.16 | 2Nos. 200Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (UPS Input Panel and Spare, ) | BI01010001010000000000000515BI0100001942 | ||
| 826 | 246.17 | 2 Nos. 125Amps, TP+N, 35KA, MCCB with Thermal Magnetic based OL,SC releases (Spare ) | BI01010001010000000000000515BI0100001943 | ||
| 827 | 246.18 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001944 | ||
| 828 | 247 | UTILITY PANEL | BI01010001010000000000000515BI0100001945 | 1 | Nos. |
| 829 | 247.01 | Incomer - 1 : (Main EB Panel) | BI01010001010000000000000515BI0100001946 | ||
| 830 | 247.02 | 1 No. 250Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001947 | ||
| 831 | 247.03 | Metering (EB): | BI01010001010000000000000515BI0100001948 | ||
| 832 | 247.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 250/5A,class 1 for metering 1 No. Ammeter &n Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001949 | ||
| 833 | 247.05 | OUTGOINGS | BI01010001010000000000000515BI0100001950 | ||
| 834 | 247.06 | 1Nos. 100Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (STP Panel, ) | BI01010001010000000000000515BI0100001951 | ||
| 835 | 247.07 | 6 Nos. 63Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (PHE panel ,external LIghting Panel and Spare,) | BI01010001010000000000000515BI0100001952 | ||
| 836 | 247.08 | 1Nos. 40Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (STP Panel) | BI01010001010000000000000515BI0100001953 | ||
| 837 | 247.09 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001954 | ||
| 838 | 248 | APFCR PANEL | BI01010001010000000000000515BI0100001955 | 1 | Nos. |
| 839 | 248.01 | Incomer - 1 : (Main EB Panel) | BI01010001010000000000000515BI0100001956 | ||
| 840 | 248.02 | 1 No. 630Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001957 | ||
| 841 | 248.03 | Metering (EB): | BI01010001010000000000000515BI0100001958 | ||
| 842 | 248.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 630/5A,class 1 for metering 1 Set of APFCR Relay\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001959 | ||
| 843 | 248.05 | OUTGOINGS | BI01010001010000000000000515BI0100001960 | ||
| 844 | 248.06 | 2Nos. 250Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (100 kVAR) | BI01010001010000000000000515BI0100001961 | ||
| 845 | 248.07 | 2Nos. 100Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (50 kVAR) | BI01010001010000000000000515BI0100001962 | ||
| 846 | 248.08 | 5Nos. 63Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (20 kVAR,10 kVAR and Spare) | BI01010001010000000000000515BI0100001963 | ||
| 847 | 248.09 | 2nos 100kVAR (480V) Capacitor banks controlled by suitable rating capacitor duty contactors & 7% detuned reactor with On/Off indicator and push button. | BI01010001010000000000000515BI0100001964 | ||
| 848 | 248.1 | 2nos 50kVAR (480V) Capacitor banks controlled by suitable rating capacitor duty contactors & 7% detuned reactor with On/Off indicator and push button. | BI01010001010000000000000515BI0100001965 | ||
| 849 | 248.11 | 2nos 20kVAR (480V) Capacitor banks controlled by suitable rating capacitor duty contactors & 7% detuned reactor with On/Off indicator and push button. | BI01010001010000000000000515BI0100001966 | ||
| 850 | 248.12 | 1nos 10kVAR (480V) Capacitor banks controlled by suitable rating capacitor duty contactors & 7% detuned reactor with On/Off indicator and push button. | BI01010001010000000000000515BI0100001967 | ||
| 851 | 248.13 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001968 | ||
| 852 | 249 | LIFT MAIN PANEL | BI01010001010000000000000515BI0100001969 | 1 | Nos. |
| 853 | 249.01 | Incomer - 1 : (Utility Panel) | BI01010001010000000000000515BI0100001970 | ||
| 854 | 249.02 | 1 No. 100Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001971 | ||
| 855 | 249.03 | Metering (EB): | BI01010001010000000000000515BI0100001972 | ||
| 856 | 249.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 100/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001973 | ||
| 857 | 249.05 | OUTGOINGS | BI01010001010000000000000515BI0100001974 | ||
| 858 | 249.06 | 5Nos. 63Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Lift Panel 1 to 4,Spare, ) | BI01010001010000000000000515BI0100001975 | ||
| 859 | 249.07 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001976 | ||
| 860 | 250 | EXTERNAL LIGHTING PANEL | BI01010001010000000000000515BI0100001977 | 1 | Nos. |
| 861 | 250.01 | Incomer - 1 : (Utility Panel) | BI01010001010000000000000515BI0100001978 | ||
| 862 | 250.02 | 1 No. 63Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001979 | ||
| 863 | 250.03 | Metering (EB): | BI01010001010000000000000515BI0100001980 | ||
| 864 | 250.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 63/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001981 | ||
| 865 | 250.05 | OUTGOINGS | BI01010001010000000000000515BI0100001982 | ||
| 866 | 250.06 | 10Nos. 40Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Lift Panel 1 to 4,Spare, ) | BI01010001010000000000000515BI0100001983 | ||
| 867 | 250.07 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001984 | ||
| 868 | 251 | BUILDING MAIN PANEL | BI01010001010000000000000515BI0100001985 | 1 | Nos. |
| 869 | 251.01 | Incomer - 1 : (Main EB Panel) | BI01010001010000000000000515BI0100001986 | ||
| 870 | 251.02 | 1 No. 630Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001987 | ||
| 871 | 251.03 | Metering (EB): | BI01010001010000000000000515BI0100001988 | ||
| 872 | 251.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 630/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001989 | ||
| 873 | 251.05 | OUTGOINGS | BI01010001010000000000000515BI0100001990 | ||
| 874 | 251.06 | 1Nos. 315Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Level 3450 R/P Panel, ) | BI01010001010000000000000515BI0100001991 | ||
| 875 | 251.07 | 1Nos. 160Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Level 150 R/P Panel, ) | BI01010001010000000000000515BI0100001992 | ||
| 876 | 251.08 | 11Nos. 63Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100001993 | ||
| 877 | 251.09 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100001994 | ||
| 878 | 252 | FLOOR LIGHTING PANEL | BI01010001010000000000000515BI0100001995 | 5 | Nos. |
| 879 | 252.01 | Incomer - 1 : (Buliding Main Panel) | BI01010001010000000000000515BI0100001996 | ||
| 880 | 252.02 | 1 No. 63Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100001997 | ||
| 881 | 252.03 | Metering (EB): | BI01010001010000000000000515BI0100001998 | ||
| 882 | 252.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 63/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100001999 | ||
| 883 | 252.05 | OUTGOINGS | BI01010001010000000000000515BI0100002000 | ||
| 884 | 252.06 | 8Nos.40Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Level 3450 R/P Panel, ) | BI01010001010000000000000515BI0100002001 | ||
| 885 | 252.07 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002002 | ||
| 886 | 253 | FLOOR EMERGENCY LIGHTING PANEL | BI01010001010000000000000515BI0100002003 | 5 | Nos. |
| 887 | 253.01 | Incomer - 1 : (UPS) | BI01010001010000000000000515BI0100002004 | ||
| 888 | 253.02 | 1 No. 63Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002005 | ||
| 889 | 253.03 | Metering (EB): | BI01010001010000000000000515BI0100002006 | ||
| 890 | 253.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 63/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002007 | ||
| 891 | 253.05 | OUTGOINGS | BI01010001010000000000000515BI0100002008 | ||
| 892 | 253.06 | 6Nos.40Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases (Level 3450 R/P Panel, ) | BI01010001010000000000000515BI0100002009 | ||
| 893 | 253.07 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002010 | ||
| 894 | 254 | FLOOR RAW POWER PANEL 150 LEVEL | BI01010001010000000000000515BI0100002011 | 1 | Nos. |
| 895 | 254.01 | Incomer - 1 : (Buliding Main Panel) | BI01010001010000000000000515BI0100002012 | ||
| 896 | 254.02 | 1 No. 160Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002013 | ||
| 897 | 254.03 | Metering (EB): | BI01010001010000000000000515BI0100002014 | ||
| 898 | 254.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 160/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002015 | ||
| 899 | 254.05 | OUTGOINGS | BI01010001010000000000000515BI0100002016 | ||
| 900 | 254.06 | 2Nos.63Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002017 | ||
| 901 | 254.07 | 7Nos.40Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002018 | ||
| 902 | 254.08 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002019 | ||
| 903 | 255 | FLOOR RAW POWER PANEL 3150 LEVEL | BI01010001010000000000000515BI0100002020 | 1 | Nos. |
| 904 | 255.01 | Incomer - 1 : (Buliding Main Panel) | BI01010001010000000000000515BI0100002021 | ||
| 905 | 255.02 | 1 No. 315Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002022 | ||
| 906 | 255.03 | Metering (EB): | BI01010001010000000000000515BI0100002023 | ||
| 907 | 255.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 315/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002024 | ||
| 908 | 255.05 | OUTGOINGS | BI01010001010000000000000515BI0100002025 | ||
| 909 | 255.06 | 1Nos.250Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002026 | ||
| 910 | 255.07 | 1Nos.63Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002027 | ||
| 911 | 255.08 | 6Nos.40Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002028 | ||
| 912 | 255.09 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002029 | ||
| 913 | 256 | FLOOR RAW POWER PANEL | BI01010001010000000000000515BI0100002030 | 3 | Nos. |
| 914 | 256.01 | Incomer - 1 : (Buliding Main Panel) | BI01010001010000000000000515BI0100002031 | ||
| 915 | 256.02 | 1 No. 63Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002032 | ||
| 916 | 256.03 | Metering (EB): | BI01010001010000000000000515BI0100002033 | ||
| 917 | 256.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 63/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002034 | ||
| 918 | 256.05 | OUTGOINGS | BI01010001010000000000000515BI0100002035 | ||
| 919 | 256.06 | 6Nos.40Amps, TP+N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002036 | ||
| 920 | 256.07 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002037 | ||
| 921 | 257 | UPS INPUT PANEL | BI01010001010000000000000515BI0100002038 | 1 | Nos. |
| 922 | 257.01 | Incomer - 1 : (Buliding Main Panel) | BI01010001010000000000000515BI0100002039 | ||
| 923 | 257.02 | 1 No. 200Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002040 | ||
| 924 | 257.03 | Metering (EB): | BI01010001010000000000000515BI0100002041 | ||
| 925 | 257.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 200/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002042 | ||
| 926 | 257.05 | OUTGOINGS | BI01010001010000000000000515BI0100002043 | ||
| 927 | 257.06 | 8Nos.63Amps, TP+2N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002044 | ||
| 928 | 257.07 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002045 | ||
| 929 | 258 | UPS OUTPUT PANEL | BI01010001010000000000000515BI0100002046 | 1 | Nos. |
| 930 | 258.01 | Incomer - 1 : (UPS) | BI01010001010000000000000515BI0100002047 | ||
| 931 | 258.02 | 5 No. 63Amps, 4Pole, 36KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002048 | ||
| 932 | 258.03 | Metering (EB): | BI01010001010000000000000515BI0100002049 | ||
| 933 | 258.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 63/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002050 | ||
| 934 | 258.05 | Bus Coupler: | BI01010001010000000000000515BI0100002051 | ||
| 935 | 258.06 | 4 Nos 63Amps, 4Pole, 36KA, complete with microprocessor based OL, SC, releases and all other accessories. | BI01010001010000000000000515BI0100002052 | ||
| 936 | 258.07 | INTERLOCKING | BI01010001010000000000000515BI0100002053 | ||
| 937 | 258.08 | 4 Nos Electro - Mechanical interlocking arrangements provided between the UPS Incomers | BI01010001010000000000000515BI0100002054 | ||
| 938 | 258.09 | OUTGOINGS | BI01010001010000000000000515BI0100002055 | ||
| 939 | 258.1 | 30Nos.40Amps, TP+2N, 35KA, MCCB with microprocessor based OL,SC releases | BI01010001010000000000000515BI0100002056 | ||
| 940 | 258.11 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002057 | ||
| 941 | 259 | LIFT PANEL | BI01010001010000000000000515BI0100002058 | 4 | Nos. |
| 942 | 259.01 | Incomer - 1 : (Lift Main Panel) | BI01010001010000000000000515BI0100002059 | ||
| 943 | 259.02 | 1 No. 63Amps, 4Pole, 16KA, MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002060 | ||
| 944 | 259.03 | Metering (EB): | BI01010001010000000000000515BI0100002061 | ||
| 945 | 259.04 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 200/5A,class 1 for metering 1 No. Ammeter & Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 40KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002062 | ||
| 946 | 259.05 | OUTGOINGS | BI01010001010000000000000515BI0100002063 | ||
| 947 | 259.06 | 1Nos.40Amps,DP RCCB 30mA | BI01010001010000000000000515BI0100002064 | ||
| 948 | 259.07 | 4Nos.40Amps, SPN MCB 10kA | BI01010001010000000000000515BI0100002065 | ||
| 949 | 259.08 | 1Nos.32Amps, SPN MCB 10kA | BI01010001010000000000000515BI0100002066 | ||
| 950 | 259.09 | 1Nos.16Amps, SPN MCB 10kA | BI01010001010000000000000515BI0100002067 | ||
| 951 | 259.1 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002068 | ||
| 952 | 260 | HVAC MAIN PANEL; | BI01010001010000000000000515BI0100002069 | 1 | No |
| 953 | 260.01 | 1no of 1250A ,50KA ACB EDO complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. ACB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002070 | ||
| 954 | 260.02 | Metering (EB): | BI01010001010000000000000515BI0100002071 | ||
| 955 | 260.03 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 1250/5A,class 1 for metering 1 No. Ammeter &n Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 50KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002072 | ||
| 956 | 260.04 | 1250A TPN AL. Bus Bar | BI01010001010000000000000515BI0100002073 | ||
| 957 | 260.05 | OUTGOINGS | BI01010001010000000000000515BI0100002074 | ||
| 958 | 260.06 | 630A TPN MCCB Mp based - 1 No | BI01010001010000000000000515BI0100002075 | ||
| 959 | 260.07 | 400A TPN MCCB Mp based - 2 Nos | BI01010001010000000000000515BI0100002076 | ||
| 960 | 260.08 | 160A TPN MCCB TM based - 2 Nos | BI01010001010000000000000515BI0100002077 | ||
| 961 | 260.09 | 125A TPN MCCB TM based - 1 No | BI01010001010000000000000515BI0100002078 | ||
| 962 | 260.1 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002079 | ||
| 963 | 261 | HVAC PANEL 1 @ +150 | BI01010001010000000000000515BI0100002080 | 1 | No |
| 964 | 261.01 | 1no of 400A ,TPN 36KA MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. MCCB complete with microprocessor based OL, SC, UV, ST & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002081 | ||
| 965 | 261.02 | Metering (EB): | BI01010001010000000000000515BI0100002082 | ||
| 966 | 261.03 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 400/5A,class 1 for metering 1 No. Ammeter &n Voltmeter\n2 Set of Control MCBs | BI01010001010000000000000515BI0100002083 | ||
| 967 | 261.04 | 400A TPN AL. Bus Bar | BI01010001010000000000000515BI0100002084 | ||
| 968 | 261.05 | OUTGOINGS | BI01010001010000000000000515BI0100002085 | ||
| 969 | 261.06 | 16A TPN MCB - 5 Nos | BI01010001010000000000000515BI0100002086 | ||
| 970 | 261.07 | 40A TP MPCB with DOL Starter and OLR - 2Nos | BI01010001010000000000000515BI0100002087 | ||
| 971 | 261.08 | 32A TP MPCB with DOL Starter and OLR -12Nos | BI01010001010000000000000515BI0100002088 | ||
| 972 | 261.09 | 20A TP MPCB with DOL Starter and OLR -12Nos | BI01010001010000000000000515BI0100002089 | ||
| 973 | 261.1 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002090 | ||
| 974 | 262 | HVAC PANEL 2 @ +3450 & +7450 | BI01010001010000000000000515BI0100002091 | 1 | No |
| 975 | 262.01 | 1no of 125A ,TPN 25KA MCCB complete with TM based OL, SC, & earth fault releases, shutter assembly, door interlock and all other accessories. MCCB complete with TM based OL, SC, & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002092 | ||
| 976 | 262.02 | Metering (EB): | BI01010001010000000000000515BI0100002093 | ||
| 977 | 262.03 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 125/5A,class 1 for metering 1 No. Ammeter &n Voltmeter\n2 Set of Control MCBs\n1 No. 3P+N, Type-2, 50KA Surge protection Device with wiring | BI01010001010000000000000515BI0100002094 | ||
| 978 | 262.04 | 125A TPN AL. Bus Bar | BI01010001010000000000000515BI0100002095 | ||
| 979 | 262.05 | OUTGOINGS | BI01010001010000000000000515BI0100002096 | ||
| 980 | 262.06 | 16A TPN MCB - 3 Nos | BI01010001010000000000000515BI0100002097 | ||
| 981 | 262.07 | 32A TP MPCB with DOL Starter and OLR - 5 Nos | BI01010001010000000000000515BI0100002098 | ||
| 982 | 262.08 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002099 | ||
| 983 | 263 | HVAC PANEL 3 @ +10.30 & +15.50MTR | BI01010001010000000000000515BI0100002100 | 1 | No |
| 984 | 263.01 | 1no of 160A ,TPN 25KA MCCB complete with TM based OL, SC, & earth fault releases, shutter assembly, door interlock and all other accessories. MCCB complete with TM based OL, SC, & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002101 | ||
| 985 | 263.02 | Metering (EB): | BI01010001010000000000000515BI0100002102 | ||
| 986 | 263.03 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 160/5A,class 1 for metering 1 No. Ammeter &n Voltmeter\n2 Set of Control MCBs | BI01010001010000000000000515BI0100002103 | ||
| 987 | 263.04 | 160A TPN AL. Bus Bar | BI01010001010000000000000515BI0100002104 | ||
| 988 | 263.05 | OUTGOINGS | BI01010001010000000000000515BI0100002105 | ||
| 989 | 263.06 | 40A TP MPCB with Star Delta Starter and OLR - 3 Nos | BI01010001010000000000000515BI0100002106 | ||
| 990 | 263.07 | 32A MPCB with DOL Starter and OLR - 2 Nos | BI01010001010000000000000515BI0100002107 | ||
| 991 | 263.08 | 20A MPCB with DOL Starter and OLR - 5 Nos | BI01010001010000000000000515BI0100002108 | ||
| 992 | 263.09 | 16A TP MCB - 2 Nos | BI01010001010000000000000515BI0100002109 | ||
| 993 | 263.1 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002110 | ||
| 994 | 264 | TERRACE HVAC PANEL | BI01010001010000000000000515BI0100002111 | 1 | NO |
| 995 | 264.01 | 1no of 630A ,TPN 36KA MCCB complete with Microprocessor based OL, SC, & earth fault releases, shutter assembly, door interlock and all other accessories. MCCB complete with Microprocessor based OL, SC, & earth fault releases, shutter assembly, door interlock and all other accessories. | BI01010001010000000000000515BI0100002112 | ||
| 996 | 264.02 | Metering (EB): | BI01010001010000000000000515BI0100002113 | ||
| 997 | 264.03 | 1 Set of RYB Phase indication LED lamps\n1 set of Breaker ON, Breaker OFF, Breaker Trip Indication lamps\n1 Set of Current transformers of ratio 630/5A,class 1 for metering 1 No. Ammeter &n Voltmeter\n2 Set of Control MCBs | BI01010001010000000000000515BI0100002114 | ||
| 998 | 264.04 | 630A TPN AL. Bus Bar | BI01010001010000000000000515BI0100002115 | ||
| 999 | 264.05 | OUTGOINGS | BI01010001010000000000000515BI0100002116 | ||
| 1000 | 264.06 | 63A TPN MCB - 9 Nos | BI01010001010000000000000515BI0100002117 | ||
| 1001 | 264.07 | 40A TPN MCB - 7 Nos | BI01010001010000000000000515BI0100002118 | ||
| 1002 | 264.08 | 25A TPN MCB - 2 Nos | BI01010001010000000000000515BI0100002119 | ||
| 1003 | 264.09 | 16A TPN MCB - 4 Nos | BI01010001010000000000000515BI0100002120 | ||
| 1004 | 264.1 | a) All the outgoing breakers with O/C, Time adjustable short circuit releases. \nb) All the outgoing feeders shall be provided with ON/OFF indication lamps. c) Suitable Busbar to be provided as per Current Density.\nd) Suitable size outgoing cable chamber, earthing arrangements should be provided for connecting the number of outgoing cables. The board shall be fabricated for future extension of the panel board. | BI01010001010000000000000515BI0100002121 | ||
| 1005 | 265 | PART - C : LIGHTING DBs, POWER DBs, & RECEPTACLES: | BI01010001010000000000000515BI0100002122 | ||
| 1006 | 266 | Supply, erection, earthing, testing and commissioning of the following MCB type Lighting and Power DB's IP 43 Protection Double Door type with powder coated including all interconnections and accessories like bolts, nuts etc; Legrand(Ekinox 3) / Schneider-Acti9/Hager - Novello+/ Seimens BETAGUARD/Crabtree Xpro classique-II/ | BI01010001010000000000000515BI0100002123 | ||
| 1007 | 267 | LIGHTING DISTRIBUTION BOARD: LDB | BI01010001010000000000000515BI0100002124 | ||
| 1008 | 267.01 | LDB - 8Way 7Segment type, Phase segregation compartmental type MCB DB comprising of the following: | BI01010001010000000000000515BI0100002125 | ||
| 1009 | 267.02 | Incomer : 1 No. 63Amps, 4Pole MCB (\"C\" curve) | BI01010001010000000000000515BI0100002126 | ||
| 1010 | 267.03 | Phase Segregation : 3 Nos. 25Amps, 30mA DP ELCB | BI01010001010000000000000515BI0100002127 | ||
| 1011 | 267.04 | Outgoings : 24 Nos. 6/10Amps, SP MCB (\"C\" curve) | BI01010001010000000000000515BI0100002128 | 22 | Nos. |
| 1012 | 268 | RAW POWER DISTRIBUTION BOARD: PDB | BI01010001010000000000000515BI0100002129 | ||
| 1013 | 268.01 | LDB - 6Way 7Segment type, Phase segregation compartmental type MCB DB comprising of the following: | BI01010001010000000000000515BI0100002130 | ||
| 1014 | 268.02 | Incomer : 1 No. 63Amps, 4Pole MCB (\"C\" curve) | BI01010001010000000000000515BI0100002131 | ||
| 1015 | 268.03 | Phase Segregation : 3 Nos. 25Amps, 30mA DP ELCB | BI01010001010000000000000515BI0100002132 | ||
| 1016 | 268.04 | Outgoings : 18 Nos. 6/10Amps, SP MCB (\"C\" curve) | BI01010001010000000000000515BI0100002133 | 22 | Nos. |
| 1017 | 269 | UPS DISTRIBUTION BOARD: UDB | BI01010001010000000000000515BI0100002134 | ||
| 1018 | 269.01 | LDB - 6Way 7Segment type, Phase segregation compartmental type MCB DB comprising of the following: | BI01010001010000000000000515BI0100002135 | ||
| 1019 | 269.02 | Incomer : 1 No. 63Amps, 4Pole MCB (\"C\" curve) | BI01010001010000000000000515BI0100002136 | ||
| 1020 | 269.03 | Phase Segregation : 3 Nos. 25Amps, 100mA DP ELCB | BI01010001010000000000000515BI0100002137 | ||
| 1021 | 269.04 | Outgoings : 18 Nos. 6/10Amps, SP MCB (\"C\" curve) | BI01010001010000000000000515BI0100002138 | 22 | Nos. |
| 1022 | 270 | EMERGENCY LIGHTING DISTRIBUTION BOARD: ELDB | BI01010001010000000000000515BI0100002139 | ||
| 1023 | 270.01 | LDB - 12Way SPN MCB DB comprising of the following: | BI01010001010000000000000515BI0100002140 | ||
| 1024 | 270.02 | Incomer : 1 No. 25Amps, 100mA DP ELCB | BI01010001010000000000000515BI0100002141 | ||
| 1025 | 270.03 | Outgoings : 6 Nos. 16Amps, SP MCB (\"D\" curve) | BI01010001010000000000000515BI0100002142 | 22 | Nos. |
| 1026 | 271 | External Lighting Distribution Board: | BI01010001010000000000000515BI0100002143 | ||
| 1027 | 271.01 | EX. LDB - 6Way, ETPN compartmental type MCB DB comprising of the following: | BI01010001010000000000000515BI0100002144 | ||
| 1028 | 271.02 | Incomer : 1 No. 63Amps, 4Pole MCB (\"C\" curve) with 24 Hrs. Timer + Power Contactor for Automatic switching the lighting circuit | BI01010001010000000000000515BI0100002145 | ||
| 1029 | 271.03 | Outgoings : 3 Nos. 16Amps, TP MCB (\"C\" curve)\n 3 Nos. 10Amps SP MCB (\"C\" curve) | BI01010001010000000000000515BI0100002146 | 3 | No. |
| 1030 | 272 | ISOLATORS, MCB & MCCBs: | BI01010001010000000000000515BI0100002147 | ||
| 1031 | 272.01 | Supply, installation, testing and commissioning of the following ISOLATORs, MCBs & MCCBs, etc. in suitable size sheet steel enclosures, fixed on the wall / frame including all interconnections and all accessories as required., | BI01010001010000000000000515BI0100002148 | ||
| 1032 | 272.02 | 10A - 32Amps TPN MCB with suitable MS enclosure (Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4 / Crabtree-Xpro/L&T-AU) | BI01010001010000000000000515BI0100002149 | 70 | Nos |
| 1033 | 272.03 | 40A - 63Amps TPN MCB with suitable MS enclosure | BI01010001010000000000000515BI0100002150 | 2 | Nos |
| 1034 | 272.04 | 100A, 4P, 16kA Isolator enclosed in metal clad wether proof enclosure Box. | BI01010001010000000000000515BI0100002151 | 4 | Nos |
| 1035 | 273 | Supply Installation, testing and commissioning of 16/20Amps, 1Phase, 2Pin+E, Industrial type plug & socket with 20A SP MCB in manufacturer's sheet steel (MS) enclosure to be fixed in wall / frame / column as required. | BI01010001010000000000000515BI0100002152 | 4 | Set |
| 1036 | 274 | Supply Installation, testing and commissioning of 32Amps, 3Phase, 3Pin+N+E, Industrial type plug & socket with 32A 4P MCB in manufacturer's sheet steel (MS) enclosure to be fixed in wall / frame / column as required. | BI01010001010000000000000515BI0100002153 | 4 | Set |
| 1037 | 275 | PART - D : LIGHTING AND POWER WIRING | BI01010001010000000000000515BI0100002154 | ||
| 1038 | 276 | Point Wiring : | BI01010001010000000000000515BI0100002155 | ||
| 1039 | 277 | Point wiring of light, using 1100 volt grade, 2 Runs of 1.5 sqmm multi strand FRLS insulated copper conductor wire along with 1 Run of 1.5 sq.mm multi strand FRLS insulated copper earth wire, drawn in 19/20mm dia, 2mm thick rigid FRLS PVC conduit in a concealed / open conduit system. The wiring shall be complete with all conduit and wiring accessories like deep junction boxes, collars, tees, bends, elbows, MS boxes, GI pull wires, clamps, spacers, screws, etc. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third core of the cable, DB to switch control will be measured as circuit wiring. The switch boxes shall be flush mounted in brick wall. The point wiring shall be as per specification. | BI01010001010000000000000515BI0100002156 | ||
| 1040 | 277.01 | Single Light point controlled by 6 A Modular type switch (Legrand MYRIUS / Crabtree\nATHENA/ANCHOR VISION) | BI01010001010000000000000515BI0100002157 | 500 | Nos |
| 1041 | 277.02 | Two light points controlled by 6 A Modular type switch | BI01010001010000000000000515BI0100002158 | 500 | Nos |
| 1042 | 277.03 | Three light points controlled by 6 A Modular type switch | BI01010001010000000000000515BI0100002159 | 150 | Nos |
| 1043 | 277.04 | 6A 3 pin receptacle located on wall or column controlled by modular type switch for exhaust fan (switch & receptacle located separately) | BI01010001010000000000000515BI0100002160 | 40 | Nos |
| 1044 | 277.05 | Ceiling fan point controlled by 6A switch. The rate shall include fan hook box, Electronic fan regulator, & other accessories as required.(1200 DIA) | BI01010001010000000000000515BI0100002161 | 20 | Nos |
| 1045 | 277.06 | Two way light point (one light controlled by 2 nos. two way switch) | BI01010001010000000000000515BI0100002162 | 26 | Nos |
| 1046 | 278 | Circuit Mains and Power Wiring : | BI01010001010000000000000515BI0100002163 | ||
| 1047 | 278.01 | Supply and laying of 1100V grade, multi strand FRLS insulated copper conductor wire. drawn into 2 mm thick rigid FRLS PVC conduit pipes in concealed / open conduit system with necessary conduit and fixing accessories like bends, collars, junction boxes, clamps, spacers, etc., complete. Wiring shall be as per specifications. | BI01010001010000000000000515BI0100002164 | ||
| 1048 | 278.02 | 2 Runs of 2.5 sqmm multi strand FRLS insulated copper conductor wire in 25 mm dia FRLS PVC conduit along with 1 Run of 2.5 sq.mm multi strand FRLS insulated copper earth wire. (For Lighting) | BI01010001010000000000000515BI0100002165 | 4500 | Mtrs |
| 1049 | 278.03 | 2 Runs of 4.0 sqmm multi strand FRLS insulated copper conductor wire in 25 mm dia FRLS PVC conduit along with 1 Run of 4 sq.mm multi strand FRLS insulated copper earth wire. (For Raw power) | BI01010001010000000000000515BI0100002166 | 4250 | Mtrs |
| 1050 | 279 | Lift well lighting | BI01010001010000000000000515BI0100002167 | ||
| 1051 | 279.01 | Supply & Wiring of elevator shaft light points using 2R x 2.5 + 1.5 Sq.mm. MSCC PVC insulted wires in 25 mm dia PVC/MS conduit (exposed as per Lift Vendor requirement for a set of light points controlled by 16A switch located at Lift M/c room, also, 6A switched socket outlets shall be provided near each light point for each floor. The rate shall include cost of switches, sockets, bulk head fittings with wire mesh & lamps and all associated accessories & as required by Inspectorate. | BI01010001010000000000000515BI0100002168 | 4 | Sets. |
| 1052 | 280 | PVC pipes | BI01010001010000000000000515BI0100002169 | ||
| 1053 | 280.01 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.( Sudhakar / AKG / BEC/ANCHOR) | BI01010001010000000000000515BI0100002170 | ||
| 1054 | 280.02 | 32 mm dia conduit | BI01010001010000000000000515BI0100002171 | 2500 | Mtrs |
| 1055 | 280.03 | 25 mm dia conduit | BI01010001010000000000000515BI0100002172 | 2000 | Mtrs |
| 1056 | 281 | Switches / Sockets (Legrand MYRIUS / Crabtre ATHENA/ANCHOR VISION) | BI01010001010000000000000515BI0100002173 | ||
| 1057 | 281.01 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 6 A modular socket outlet and 6 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100002174 | 2 | Nos |
| 1058 | 281.02 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100002175 | 2 | Nos |
| 1059 | 281.03 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 6 /16 A modular socket outlet and 16 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100002176 | 250 | Nos |
| 1060 | 281.04 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 X 6 pin 6 /16 A modular socket outlet and 16 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100002177 | 68 | Nos |
| 1061 | 281.05 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin16 A modular socket outlet and 16 A DP modular switch with indicator, connections etc. as required.( for AC) | BI01010001010000000000000515BI0100002178 | 6 | Nos |
| 1062 | 282 | PART - E:- LIGHT FIXTURES & FANS | BI01010001010000000000000515BI0100002179 | ||
| 1063 | 283 | Surface / wall / ceiling mounted light fixtures | BI01010001010000000000000515BI0100002180 | ||
| 1064 | 284 | Supply Installation, testing and commissioning of the following lighting luminaires including all necessary accessories like electronic driver, holder, control gear, fixing accessories, down rod, chain suspender, supporting arrangements, clamps, as per the site requirments(.Phillips / WIPRO/LT)\n | BI01010001010000000000000515BI0100002181 | ||
| 1065 | 284.01 | Supply , installation testing and commissioning of 24Watts LED Downlight recessed mounted type light fitting with all accessories | BI01010001010000000000000515BI0100002182 | 80 | Nos. |
| 1066 | 284.02 | Supply , installation testing and commissioning of 18Watts LED Downlight recessed mounted type light fitting with all accessories | BI01010001010000000000000515BI0100002183 | 1032 | Nos. |
| 1067 | 284.03 | Supply , installation testing and commissioning of 10Watts Mirror LED wall mounted type light fitting with all accessories as required | BI01010001010000000000000515BI0100002184 | 30 | Nos. |
| 1068 | 284.04 | Supply , installation testing and commissioning of 10Watts wall mounted type light fitting with all accessories as required | BI01010001010000000000000515BI0100002185 | 151 | Nos. |
| 1069 | 284.05 | Supply , installation,Testing & Commissioning of ceiling / surface mounted type 20Watts LED Tube light fitting with all accessoriesas required | BI01010001010000000000000515BI0100002186 | 242 | Nos. |
| 1070 | 284.06 | Supply , installation testing and commissioning of 30Watts LED Downlight recessed mounted type light fitting with all accessories Seminor Stage Area. | BI01010001010000000000000515BI0100002187 | 6 | Nos. |
| 1071 | 284.07 | Supply , installation testing and commissioning of 20Watts LED Downlight recessed mounted type light fitting with all accessories Seating Area-2 | BI01010001010000000000000515BI0100002188 | 70 | Nos. |
| 1072 | 284.08 | Supply , installation testing and commissioning of 90Watts LED Downlight recessed mounted type light fitting with all accessories Seating Area-1 | BI01010001010000000000000515BI0100002189 | 52 | Nos. |
| 1073 | 284.09 | Supply , installation testing and commissioning of 150Watts LED Downlight fitting mounted on Truss with supprot and all accessories.Audi Stage Area | BI01010001010000000000000515BI0100002190 | 17 | Nos. |
| 1074 | 284.1 | Supply and Erection of LED Gate Light fitting with supports and all accessories as complete, | BI01010001010000000000000515BI0100002191 | 4 | Nos. |
| 1075 | 284.11 | Supply, installation of 10Watts LED bulk head light fitting | BI01010001010000000000000515BI0100002192 | 20 | Nos. |
| 1076 | 284.12 | Supply and fixing of 110Watts outdoor type LED Flood light fitting with supports and all accessories as required | BI01010001010000000000000515BI0100002193 | 2 | Nos. |
| 1077 | 284.13 | Supply, Erection, testing and commissioning of 1200mm sweep Ceiling fan with all accessories as required(ALMONARD/HAVELLS/CROMPTON /) | BI01010001010000000000000515BI0100002194 | 4 | Nos. |
| 1078 | 284.14 | Supply, Erection, testing and commissioning of 300mm Metal type Exhaust fan with all accessories as required | BI01010001010000000000000515BI0100002195 | 47 | Nos. |
| 1079 | 284.15 | Supply , installation testing and commissioning of 30Watts LED Downlight recessed mounted type light fitting with all accessories.Entry Area Pergola Fixtures | BI01010001010000000000000515BI0100002196 | 24 | Nos. |
| 1080 | 284.16 | Supply , installation testing and commissioning of LED Step Light fitting with all accessories.Entry Area Pergola Fixtures | BI01010001010000000000000515BI0100002197 | 64 | Nos |
| 1081 | 284.17 | Supply , installation testing and commissioning of 10Watts LED Bollard light fitting with all accessories as required-(Wether Proof) | BI01010001010000000000000515BI0100002198 | 52 | Nos. |
| 1082 | 284.18 | Supply and erection of 70w street light fixture and 7 Mtr. Long GI Octagonal pole with suitable size base plate, foundation bolt nuts, single arm bracket, etc., complete with 2 x 50mm dia PVC Pipe for cable entry and exit in bottom of the pole, control MCB, connector block, 3C x 2.5 Sq.mm copper flexible cable from JB to light fitting, etc., | BI01010001010000000000000515BI0100002199 | 22 | Nos. |
| 1083 | 285 | PART - F : BUS DUCT | BI01010001010000000000000515BI0100002200 | ||
| 1084 | 286 | Supply, Installation,unloading,storing,shifting,Testing & commissioning of 1600A,65kA, 433V,4P(TP+N) +E, sandwich type, Aluminium Bus duct( IS 8623) with the following configuration : 3 phase + 100 % neutral + 50 % internal earth, of (IP 54) with metal clad enclosure made out of powder coated sheet steel in convinient sections complete with aluminium busbars, necessary joints, elbow joints, expansion joints, end flange with flexibles, continious earthing with 2nos aluminium strip of suitable size, one on each side including GI clamping brackets/Suspenders etc as per specifications. (Outdoor Type) (Transformer to LT Kiosk, LT Kiosk to Main Panel) | BI01010001010000000000000515BI0100002201 | 20 | Mtr |
| 1085 | 286.01 | Straight run | BI01010001010000000000000515BI0100002202 | ||
| 1086 | 286.02 | End flange | BI01010001010000000000000515BI0100002203 | ||
| 1087 | 286.03 | Vertical bends | BI01010001010000000000000515BI0100002204 | ||
| 1088 | 286.04 | Horizontal bends | BI01010001010000000000000515BI0100002205 | ||
| 1089 | 286.05 | Flexibles | BI01010001010000000000000515BI0100002206 | ||
| 1090 | 286.06 | Adaptor Box | BI01010001010000000000000515BI0100002207 | ||
| 1091 | 287 | Supply, Installation,unloading,storing,shifting,Testing & commissioning of 1600A,65kA, 433V,4P(TP+N) +E, sandwich type, Aluminium Bus duct( IS 8623) with the following configuration : 3 phase + 100 % neutral + 50 % internal earth, of (IP 54) with metal clad enclosure made out of powder coated sheet steel in convinient sections complete with aluminium busbars, necessary joints, elbow joints, expansion joints, end flange with flexibles, continious earthing with 2nos aluminium strip of suitable size, one on each side including GI clamping brackets/Suspenders etc as per specifications. (Indoor Type) (DG Synchronizing Panel to Main Panel) | BI01010001010000000000000515BI0100002208 | 20 | Mtr |
| 1092 | 287.01 | Straight run | BI01010001010000000000000515BI0100002209 | ||
| 1093 | 287.02 | End flange | BI01010001010000000000000515BI0100002210 | ||
| 1094 | 287.03 | Vertical bends | BI01010001010000000000000515BI0100002211 | ||
| 1095 | 287.04 | Horizontal bends | BI01010001010000000000000515BI0100002212 | ||
| 1096 | 287.05 | Flexibles | BI01010001010000000000000515BI0100002213 | ||
| 1097 | 287.06 | Adaptor Box | BI01010001010000000000000515BI0100002214 | ||
| 1098 | 288 | PART - G : LT CABLES & END TERMINATIONS | BI01010001010000000000000515BI0100002215 | ||
| 1099 | 289 | Supply, laying , testing and commissioning of the following size XLPE insulated (1100V grade) aluminium / copper conductor armoured cable laid in cable tray / clamping in wall/ laid in the cable trench with suitable dressing tags and clamps. (KEI / POLYCAB / RR CABLE/HAVELLS) | BI01010001010000000000000515BI0100002216 | ||
| 1100 | 289.01 | 3.5C 400 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002217 | 1200 | Mtr |
| 1101 | 289.02 | 3.5C 300 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002218 | 245 | Mtr |
| 1102 | 289.03 | 3.5C 240 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002219 | 178 | Mtr |
| 1103 | 289.04 | 3.5C 185 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002220 | 40 | Mtr |
| 1104 | 289.05 | 3.5C 150 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002221 | 5 | Mtr |
| 1105 | 289.06 | 3.5C 120 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002222 | 450 | Mtr |
| 1106 | 289.07 | 3.5C 95 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002223 | 322 | Mtr |
| 1107 | 289.08 | 3.5C 70 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002224 | 20 | Mtr |
| 1108 | 289.09 | 3.5C 50 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002225 | 25 | Mtr |
| 1109 | 289.1 | 3.5C 35 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002226 | 25 | Mtr |
| 1110 | 289.11 | 4 Core 25 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002227 | 4250 | Mtr |
| 1111 | 289.12 | 4 Core 16 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002228 | 3350 | Mtr |
| 1112 | 289.13 | 4 Core 10 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002229 | 5 | Mtr |
| 1113 | 289.14 | 4 Core 6 Sq.mm PVC Copper armoured Cable | BI01010001010000000000000515BI0100002230 | 1000 | Mtr |
| 1114 | 289.15 | 4 Core 4 Sq.mm PVC Copper armoured Cable | BI01010001010000000000000515BI0100002231 | 2500 | Mtr |
| 1115 | 289.16 | 4 Core 2.5 Sq.mm PVC Copper armoured Cable | BI01010001010000000000000515BI0100002232 | 1500 | Mtr |
| 1116 | 289.17 | 3 Core 4.0 Sq.mm PVC Copper Armoured Cable | BI01010001010000000000000515BI0100002233 | 1500 | Mtr |
| 1117 | 289.18 | 3 Core 2.5 Sq.mm PVC Copper Armoured Cable | BI01010001010000000000000515BI0100002234 | 2000 | Mtr |
| 1118 | 289.19 | 24 Core 2.5 Sq.mm PVC Copper Armoured Cable | BI01010001010000000000000515BI0100002235 | 20 | Mtr |
| 1119 | 289.2 | 1Core 16 Sq.mm XLPE Copper Flexible Cable for UPS | BI01010001010000000000000515BI0100002236 | 410 | Mtr |
| 1120 | 289.21 | 1Core 6 Sq.mm XLPE Copper Flexible Cable for UPS | BI01010001010000000000000515BI0100002237 | 120 | Mtr |
| 1121 | 290 | Supply and fixing of end termination of the following size cables with suitable Double compression glands and suitable size crimping sockets, gland earthing by using 12/14SWG copper wire and all other necessary accessories . \n(Copper sockets for copper cables & Aluminium sockets for Aluminium cables) | BI01010001010000000000000515BI0100002238 | ||
| 1122 | 290.01 | 3.5C 400 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002239 | 16 | Nos. |
| 1123 | 290.02 | 3.5C 300 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002240 | 32 | Nos. |
| 1124 | 290.03 | 3.5C 240 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002241 | 2 | Nos. |
| 1125 | 290.04 | 3.5C 185 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002242 | 4 | Nos. |
| 1126 | 290.05 | 3.5C 150 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002243 | 2 | Nos. |
| 1127 | 290.06 | 3.5C 120 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002244 | 4 | Nos. |
| 1128 | 290.07 | 3.5C 95 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002245 | 4 | Nos. |
| 1129 | 290.08 | 3.5C 70 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002246 | 2 | Nos. |
| 1130 | 290.09 | 3.5C 50 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002247 | 2 | Nos. |
| 1131 | 290.1 | 3.5C 35 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002248 | 2 | Nos. |
| 1132 | 290.11 | 4 Core 25 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002249 | 2 | Nos. |
| 1133 | 290.12 | 4 Core 16 Sq.mm XLPE aluminium armoured Cable | BI01010001010000000000000515BI0100002250 | 60 | Nos. |
| 1134 | 290.13 | 4 Core 10 Sq.mm PVC aluminium armoured Cable | BI01010001010000000000000515BI0100002251 | 40 | Nos. |
| 1135 | 290.14 | 4 Core 6 Sq.mm PVC Copper armoured Cable | BI01010001010000000000000515BI0100002252 | 30 | Nos. |
| 1136 | 290.15 | 4 Core 4 Sq.mm PVC Copper armoured Cable | BI01010001010000000000000515BI0100002253 | 30 | Nos. |
| 1137 | 290.16 | 4 Core 2.5 Sq.mm PVC Copper armoured Cable | BI01010001010000000000000515BI0100002254 | 30 | Nos. |
| 1138 | 290.17 | 3 Core 4.0 Sq.mm PVC Copper Armoured Cable | BI01010001010000000000000515BI0100002255 | 40 | Nos. |
| 1139 | 290.18 | 3 Core 2.5 Sq.mm PVC Copper Armoured Cable | BI01010001010000000000000515BI0100002256 | 40 | Nos. |
| 1140 | 290.19 | 24 Core 2.5 Sq.mm PVC Copper Armoured Cable | BI01010001010000000000000515BI0100002257 | 2 | Nos |
| 1141 | 290.2 | 1Core 16 Sq.mm XLPE Copper Flexible Cable for UPS | BI01010001010000000000000515BI0100002258 | 50 | Nos |
| 1142 | 290.21 | 1Core 6 Sq.mm XLPE Copper Flexible Cable for UPS | BI01010001010000000000000515BI0100002259 | 10 | Nos |
| 1143 | 291 | PART - H : EARTHING SYSTEM | BI01010001010000000000000515BI0100002260 | ||
| 1144 | 292 | Supply, erection, testing and commissioning of GI pipe earth electrode as per IS 3043 standards complete with 3 mtrs Long, 40mm dia GI pipe including 1 run of 50 x 6mm GI flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. | BI01010001010000000000000515BI0100002261 | 26 | Nos |
| 1145 | 293 | Supply, erection and testing of Copper Plate earth electrode as per IS 3043 standards complete with 3 mtrs long, 40mm dia GI pipe, 600 x 600 x 3.15mm size Copper plate and 2 run of 25 x 3mm Copper flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. \n(UPS EARTHING) | BI01010001010000000000000515BI0100002262 | 21 | Nos |
| 1146 | 294 | Supply and laying of 50 x 6 mm GI flat | BI01010001010000000000000515BI0100002263 | 80 | Mtr |
| 1147 | 295 | Supply and laying of 25 x 6 mm GI flat | BI01010001010000000000000515BI0100002264 | 790 | Mtr |
| 1148 | 296 | Supply and laying of 25 x 3 mm GI flat | BI01010001010000000000000515BI0100002265 | 1100 | Mtr |
| 1149 | 297 | Supply and laying of 25 x 6 mm Copper flat | BI01010001010000000000000515BI0100002266 | 1035 | Mtr |
| 1150 | 298 | Supply and laying of 25 x 3 mm Copper flat | BI01010001010000000000000515BI0100002267 | 770 | Mtr |
| 1151 | 299 | Supply and laying of 8 gauge bare copper wire | BI01010001010000000000000515BI0100002268 | 250 | Mtr |
| 1152 | 300 | Supply and laying of 10 gauge bare copper wire | BI01010001010000000000000515BI0100002269 | 250 | Mtr |
| 1153 | 301 | Supply and laying of 8 gauge bare GI wire | BI01010001010000000000000515BI0100002270 | 525 | Mtr |
| 1154 | 302 | Supply and laying of 1C x 4 Sq.mm copper flexible Cable (Yellow green) | BI01010001010000000000000515BI0100002271 | 250 | Mtr |
| 1155 | 303 | Supply and laying of 1C x 6 Sq.mm copper flexible Cable (Yellow green) | BI01010001010000000000000515BI0100002272 | 200 | Mtr |
| 1156 | 304 | Supply and laying of 1C x 16 Sq.mm copper flexible Cable (Yellow green) | BI01010001010000000000000515BI0100002273 | 100 | Mtr |
| 1157 | 305 | Earth bus with hylam sheet 0.5mtr long using 25 x 3mm Cu. flat with Insulator | BI01010001010000000000000515BI0100002274 | 10 | Nos. |
| 1158 | 306 | Earth bus with hylam sheet 0.5mtr long using 50 x 6mm GI flatwith Insulator | BI01010001010000000000000515BI0100002275 | 24 | Nos. |
| 1159 | 307 | PART - I : CABLE TRAYS ,RACE WAYS & SUPPORTS | BI01010001010000000000000515BI0100002276 | ||
| 1160 | 308 | CABLE TRAYS | BI01010001010000000000000515BI0100002277 | ||
| 1161 | 308.01 | Supply and erection of following sizes GI ladder / perforated type cable rack system made out of Pre Galvanised sheet steel folded to required shape with adequate number of supports. | BI01010001010000000000000515BI0100002278 | ||
| 1162 | 308.02 | The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbows, re-deep, coupler plates, etc., The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc., The rack shall have suitable cable clamping arrangements etc. HILTI/TRUE LEADER/RMCON | BI01010001010000000000000515BI0100002279 | ||
| 1163 | 308.03 | LADDER TYPE: | BI01010001010000000000000515BI0100002280 | ||
| 1164 | 308.04 | 2mm thickness Pre-galvanised Ladder type cable tray with coupler plates, bends, anchor fasteners, etc., And the trays to be provided with MS structural supports. (Cost for the MS supports will be calculated in separate line item | BI01010001010000000000000515BI0100002281 | ||
| 1165 | 308.05 | 600mm width x 150mm Height | BI01010001010000000000000515BI0100002282 | 135 | Mtr |
| 1166 | 308.06 | 450mm width x 150mm Height | BI01010001010000000000000515BI0100002283 | 395 | Mtr |
| 1167 | 308.07 | 300mm width x 100mm Height | BI01010001010000000000000515BI0100002284 | 20 | Mtr |
| 1168 | 309 | PERFORATED TYPE: | BI01010001010000000000000515BI0100002285 | ||
| 1169 | 309.01 | 2mm thickness Pre-galvanised Perforated type cable tray with coupler plates, bends, anchor fasteners, etc., GI down rods with suitable GI supports and necessary anchor fasteners to be considered for trays upto 200mm size and cost to be included. \nAbove 300mm sizes trays to be provided with MS structural supports. (Cost for the MS supports will be calculated in separate line item) | BI01010001010000000000000515BI0100002286 | ||
| 1170 | 309.02 | 600mm width x 150mm Height | BI01010001010000000000000515BI0100002287 | 260 | Mtr |
| 1171 | 309.03 | 450mm width x 150mm Height | BI01010001010000000000000515BI0100002288 | 1324 | Mtr |
| 1172 | 309.04 | 300mm width x 150mm Height | BI01010001010000000000000515BI0100002289 | 20 | Mtr |
| 1173 | 310 | Supply, fabrication and installation of Mild Steel structural supports using MS Channel / angle / flat iron supports for Cable trays, PDBs, Panel boards, Isolators, etc., and one coat of primer & two coats of enamel paints, minor civil works etc. as required. | BI01010001010000000000000515BI0100002290 | 2 | MT |
| 1174 | 311 | Raceways | BI01010001010000000000000515BI0100002291 | ||
| 1175 | 311.01 | Supply and Installation of following size G I Raceways of 2mm thick with top\ncover and required hard ware etc suspended from the ceiling or Along the wall or in trench, in floor or on floor, HILTI/TRUE LEADER/RMCON | BI01010001010000000000000515BI0100002292 | ||
| 1176 | 311.02 | 100mm x 40mm | BI01010001010000000000000515BI0100002293 | 150 | Nos |
| 1177 | 311.03 | 150mm x 40mm | BI01010001010000000000000515BI0100002294 | 100 | Nos |
| 1178 | 311.04 | 300mm x 40mm | BI01010001010000000000000515BI0100002295 | 75 | Nos |
| 1179 | 312 | JUNCTION BOXES | BI01010001010000000000000515BI0100002296 | ||
| 1180 | 312.01 | 150mm x 50mm | BI01010001010000000000000515BI0100002297 | 75 | Nos |
| 1181 | 312.02 | 200mm x 50mm | BI01010001010000000000000515BI0100002298 | 50 | Nos |
| 1182 | 312.03 | 350mm x 50mm | BI01010001010000000000000515BI0100002299 | 40 | Nos |
| 1183 | 313 | PART - J : UPS & INVERTERS: | BI01010001010000000000000515BI0100002300 | ||
| 1184 | 313.01 | Supply, Erection, Testing and commissioning of 80 KVA UPS High Performance Double conversion with 3Phase Input / 3 Phase output with sealed maintenance free type Batteries suitable for 30 Minutes backup, battery rack, interconnection cables, etc., The cost is inclusive of inbuilt Isolation Transformer. | BI01010001010000000000000515BI0100002301 | 2 | Nos |
| 1185 | 314 | PART - K : LIGHTNING PROTECTION SYSTEM | BI01010001010000000000000515BI0100002302 | ||
| 1186 | 314.01 | Conventional type Lightning Protection: | BI01010001010000000000000515BI0100002303 | ||
| 1187 | 315 | Supply and erection of Vertical Air termination of 25mm dia. 1500mm Height Copper tube with 65mm dia. Copper ball, 5 Spike terminals, Base plate, etc., | BI01010001010000000000000515BI0100002304 | 12 | Set |
| 1188 | 316 | Supply and laying of 32 x 6mm GI horizontal conductor with suitable size DMC supporing insulators, etc., | BI01010001010000000000000515BI0100002305 | 680 | Mtr |
| 1189 | 317 | Supply and laying of 25 x 6mm GI vertical down conductor with suitable size DMC supporing insulators, etc., | BI01010001010000000000000515BI0100002306 | 910 | Mtr |
| 1190 | 318 | Supply and erection of Test link with suitable size MS enclosure | BI01010001010000000000000515BI0100002307 | 12 | Nos |
| 1191 | 319 | Supply, erection, testing and commissioning of GI pipe earth electrode as per IS 3043 standards complete with 3 mtrs Long, 40mm dia GI pipe including 1 run of 50 x 6mm GI flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. | BI01010001010000000000000515BI0100002308 | 12 | Nos |
| 1192 | 320 | PART - L : DG SET & ALLIED WORKS: | BI01010001010000000000000515BI0100002309 | ||
| 1193 | 321 | 500KVA, 415Volts DG SET | BI01010001010000000000000515BI0100002310 | ||
| 1194 | 322 | Supply, Installation, testing and commissioning of 500 kVA Silent type Diesel Generator Set complete with Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours opeartion Generally confirms to BS:5514, directly coupled to 750kVA at 0.8 Power factor, 415V, 3 Phase , 4 wires, 50 cycles per second self excited, self regulated , with brushless excitation, Alternator generally confirms to BS:5000/IS:4722 . DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box , MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with guage board, and all other accessories as per specifications and schedule. Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. DG set should consists Auto-Start Control Panel with suitable rating of MCCB isolator inside. All steel material shall be hot dip phosphated with 2 coats of primer and 2 coats of epoxy paint of approved colour. Each chamber shall be wired with light points and bulk - head light fixtures shall be provided. The cost shall also include providing 4 Nos. bulk - head fixtures in DG set chamber and 1 No. in Exhaust chamber. The temperature inside the enclosure shall not be more than 3 Deg C [?T shall be 5° C] above ambient. The noise level shall be as per CPCB II. Air intake for DG set shall be provided from rear side of the DG set and shall suck in by engine fan.Suitable louvers shall be provided at adequate height for hot air exhaust inside the accoustic enclosure, so as to maintain a differential of 5-6 degree centigrade between atmosphere and accoustic enclosure. The cost of Exhaust pipe shall be excluded in this item. \nDiesel Engine Makes: Perkins/Caterpiller/Cummins\nAlternator Makes: Stamford/Kirloskar/Leroy Somer | BI01010001010000000000000515BI0100002311 | 2 | SET |
| 1195 | 323 | Exhaust System | BI01010001010000000000000515BI0100002312 | ||
| 1196 | 324 | Supply and Installation of exhaust piping with 10\" dia MS pipe including Hardware, Nutbolts, Flanges & Gaskets steel supports (500KVA DG Set) | BI01010001010000000000000515BI0100002313 | 50 | Mtr |
| 1197 | 325 | Supply & installation of 10\" Bend.(Bends shall be measured Extra @1 Mtr) | BI01010001010000000000000515BI0100002314 | 6 | Nos |
| 1198 | 326 | Supply & installation of 50 mm thk. Insulation with rockwool density-64 kg/cm3 and 24 guage aluminium cladding for 10\" MS Pipe for 1x500KVA & 1x500KVA DG set | BI01010001010000000000000515BI0100002315 | 50 | Mtr |
| 1199 | 327 | Supply & installation of 50 mm thk. Insulation with rockwool density-64 kg/cm3 and 24 guage aluminium cladding for Silencer for 1x625KVA & 1x500KVA DG set | BI01010001010000000000000515BI0100002316 | 2 | Nos |
| 1200 | 328 | Supply, Fabrication & Installation of 1\" dia class 'B' MS Pipe | BI01010001010000000000000515BI0100002317 | 50 | Mtr |
| 1201 | 329 | Supply & Fixing of 1\" dia Ball Valve in fuel line | BI01010001010000000000000515BI0100002318 | 2 | Set |
| 1202 | 330 | Supply & Installation of 990 Ltrs Day Tank | BI01010001010000000000000515BI0100002319 | 1 | Nos |
| 1203 | 331 | Supply & Installation of MS Steel structure & support for exhaust pipe, silencers and misc. supports with 1 coat of red oxide & 2 coats of enamel paint (Including fastners wherever required | BI01010001010000000000000515BI0100002320 | 9500 | Kgs |
| 1204 | 332 | Lightning conductor above Exhaust Structure | BI01010001010000000000000515BI0100002321 | ||
| 1205 | 333 | Supply, installation, testing & commissioning of a Conventional Lightning Rod (Spike Arrester) of copper conductor which will be mounted above exhaust structure, job shall be inclusive of lightning conductor, 1 run of 25 x 3 mm copper strip with connection to earthing station. | BI01010001010000000000000515BI0100002322 | 1 | Set |
| 1206 | 334 | Aviation Light above Exhaust Structure | BI01010001010000000000000515BI0100002323 | ||
| 1207 | 334.01 | Supply, installation, testing & commissioning of aviation light above exhaust structure, with 3C x 2.5 sq. mm. copper flexible PVC cable. | BI01010001010000000000000515BI0100002324 | 1 | Set |
| 1208 | 335 | Earthing | BI01010001010000000000000515BI0100002325 | ||
| 1209 | 336 | Supply, erection and testing of GI Plate earth electrode as per IS 3043 standards complete with 3 mtrs long, 40mm dia. GI pipe, 600 x 600 x 6mm size GI plate and 2 run of 50 x 6mm GI flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. (For DG Earthing) | BI01010001010000000000000515BI0100002326 | 4 | Nos |
| 1210 | 337 | Supply, erection and testing of Copper Plate earth electrode as per IS 3043 standards complete with 3 mtrs long, 40mm dia GI pipe, 600 x 600 x 3.15mm size Copper plate and 2 run of 50 x 6mm Copper flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. \n(DG SET NEUTRAL EARTHING) | BI01010001010000000000000515BI0100002327 | 4 | Nos |
| 1211 | 338 | Supply and laying of 50 x 6 mm Copper flat - DG Neutral earthing | BI01010001010000000000000515BI0100002328 | 40 | Mtr |
| 1212 | 339 | Supply and laying of 50 x 6 mm GI flat | BI01010001010000000000000515BI0100002329 | 50 | Mtr |
| 1213 | 340 | Supply and laying of 8 gauge bare copper wire | BI01010001010000000000000515BI0100002330 | 90 | Mtr |
| 1214 | 341 | POWER CABLES: | BI01010001010000000000000515BI0100002331 | ||
| 1215 | 342 | Supply, laying, testing and commissioning of 3.5C x 400 Sq.mm 1.1KV LT XLPE Aluminium condutcor armoured UG Cable (4 Runs for 500KVA DG Set) | BI01010001010000000000000515BI0100002332 | ||
| 1216 | 343 | Supply and erection of end termination materials for 3.5C x 400 Sq.mm Al. Ar. Cable using double compression type gland and crimping type aluminium lugs and accessories. | BI01010001010000000000000515BI0100002333 | ||
| 1217 | 344 | CONTROL CABLES & TERMINATIONS: | BI01010001010000000000000515BI0100002334 | ||
| 1218 | 345 | Supply, laying, testing and commissioning of following sizes of 1100Volts Copper Armoured Control Cables | BI01010001010000000000000515BI0100002335 | ||
| 1219 | 345.01 | 4C x 2.5 Sq.mm | BI01010001010000000000000515BI0100002336 | 25 | Mtr |
| 1220 | 345.02 | 12C x 2.5 Sqmm | BI01010001010000000000000515BI0100002337 | 25 | Mtr |
| 1221 | 346 | End Terminations for above sizes of Copper Armoured Control Cables with all required accessories | BI01010001010000000000000515BI0100002338 | ||
| 1222 | 346.01 | 4C x 2.5 Sq.mm | BI01010001010000000000000515BI0100002339 | 10 | Nos |
| 1223 | 346.02 | 12C x 2.5 Sqmm | BI01010001010000000000000515BI0100002340 | 4 | Nos |
| 1224 | 347 | PART - M Data & Telephone System | BI01010001010000000000000515BI0100002341 | ||
| 1225 | 347.01 | Wiring & Sockets | BI01010001010000000000000515BI0100002342 | ||
| 1226 | 348 | Providing ,fixing , testing and commissioning of Telephone outlets including mounting boxes ,face plates and fixing accessories. | BI01010001010000000000000515BI0100002343 | 70 | Nos |
| 1227 | 349 | Providing ,fixing , testing and commissioning of computer jack (RJ45)(Data) including mounting boxes, face plates and fixing plates. | BI01010001010000000000000515BI0100002344 | 70 | Nos |
| 1228 | 350 | Providing ,fixing , testing and commissioning of Cat 6(For Tele & Data) insulated computer cable drawn in existing conduit.(Rate shall exclude the cost of 25mm PVC conduit) | BI01010001010000000000000515BI0100002345 | 1500 | Mts |
| 1229 | 351 | Providing & fixing of 2 mm thick 25mm (For Tele & Data) PVC Conduit with accessories like bends junction boxes clamps etc. The conduit shall be embedded in floor/roof/wall as required. | BI01010001010000000000000515BI0100002346 | 1200 | Mts |
| 1230 | 352 | Supply & Installation of Server Rack suitable for above mentioned system (Inclusive of all accesories like Power Strip, Patch panel, switch, Cabling, Mounting supports & patch panel(50 pair) for Tele tag block) | BI01010001010000000000000515BI0100002347 | 5 | No's |
| 1231 | 353 | Supply & fixing of Cat6 RJ45 to RJ45 7ft Patch Cord - Rack side for Data Resource | BI01010001010000000000000515BI0100002348 | 70 | Each |
| 1232 | 354 | PART - N:- CLOSED CIRCUIT TELEVISION SYSTEM | BI01010001010000000000000515BI0100002349 | ||
| 1233 | 355 | Supply, Installation, Testing and Commssioining of 1/3\" Indoor Color Dome Camera with at least 540 TV lines resolution & wit mm focal lens, auto iris, illumination Less th 3.5 to 8mm varifocal auto iris lens 1.0 Lux, Auto back light compensation, White Balance Switch Auto/Manual, POE camera as specified in the Tender Specifications with single channel encoder BOSCH / HONEYWELL /HIKVISION/ | BI01010001010000000000000515BI0100002350 | 26 | Nos |
| 1234 | 356 | Supply, Installation, Testing and Commssioining of (Indoor varyfocal camera) 1/3 \" C/CS mount Color CCD High Resolution Camera with at least TV 540 lines 795 H x 596 V resolution), 3.5 - 8 mm vary focal length, Auto Iris, illumination less than 0.5lux (faceplate) 0.05 lux @ f1.2 (SAGC, 30 IRE) , POE with indoor housing as specified in the Tender Specifications | BI01010001010000000000000515BI0100002351 | 26 | Nos |
| 1235 | 357 | Supply, Installation, Testing and Commssioining of (Out door varyfocal camera) 1/3 \" C/CS mount Color CCD Day / Night High Resolution Camera with at least TV 540 lines 795 H x 596 V (PAL) resolution, 2.7 - 13.5 mm Vary Focal Length , Auto Iris,illumination 0.01lux (faceplate) 0.002 lux in b/w mode (faceplate) , POE camera with outdoor IP66 housing as specified in the Tender Specifications | BI01010001010000000000000515BI0100002352 | 120 | Nos |
| 1236 | 358 | Supply, Installation, Testing and Commssioining of Min 1/4\" Indoor PTZ Dome Camera with variable speed/high speed pan and tilt drive unit ,continuous 360 degree rotation, Tilt Range @ 90 deg, Auto/Manual Speed of the drive,with min 460 TV lines (752(h) x 582 (v) resolution ,illumination less than Sensitivity PAL, color: 0.05 lux at 1/1.5 sec shutter speed , 18X Optical, 12X Digital zoom, Min 40 preset points,auto iris and Focus with manual override, RS 485 interface, White Balance Automatic with manual override,with wall / pole mountings as required as per Tender Specification | BI01010001010000000000000515BI0100002353 | 6 | Nos |
| 1237 | 359 | Supply, Installation, Testing and Commssioining of Min 1/4\" Outdoor PTZ Day /Night Camera with variable speed/high speed pan and tilt drive unit ,continuous 360 degree rotation, Tilt Range @ 90 deg, Auto/Manual Speed of the drive,with min 530 TV lines (752(h) x 582 (v) resolution ,PAL, color: 0.08 lux at 1/1.5 sec shutter speed B-W: 0.013 lux at 1/1.5 sec shutter speed , 35X Optical, 12X Digital zoom, Min 128 preset points,auto iris and Focus with manual override, RS 485 interface, White Balance Automatic with manual override,with outdoor IP66 housing, wall / pole mountings required as per Tender Specification | BI01010001010000000000000515BI0100002354 | 5 | Nos |
| 1238 | 360 | Supply, Installation, Testing and Commssioining of 12VDC/24VAC Power Supply units for PTZ Cameras as specified in the Tender Specifications | BI01010001010000000000000515BI0100002355 | 4 | Nos |
| 1239 | 361 | Supply, Installation, Testing and Commssioining of Digital Video Management Software with 1 client station as per Tender Specifications | BI01010001010000000000000515BI0100002356 | 1 | Lot |
| 1240 | 362 | Supply, Installation, Testing and Commssioining of Servers for Digital Video Management software as per Tender Specifications | BI01010001010000000000000515BI0100002357 | 1 | Lot |
| 1241 | 363 | Supply, Installation, Testing and Commssioining 6 TB of RAID storage for recording @ 4CIF resolution @ 25 FPS for 30days storage (vendors to size the storage and enclose storage calculation sheet) | BI01010001010000000000000515BI0100002358 | 1 | Nos |
| 1242 | 364 | Supply and laying of RG 11 Co axial Video cable & 2 Core 1.00 Sqmm copper, multi strand, overall PVC sheathed camera power cable. in 1\" FRLS PVC Conduits as specified in the Tender Specifications | BI01010001010000000000000515BI0100002359 | 1000 | Rmt |
| 1243 | 365 | Supply and Laying of RG - 11 Co-axial Armoured video cable as specified in the Tender Specifications . | BI01010001010000000000000515BI0100002360 | 1230 | Rmt |
| 1244 | 366 | Supply and underground laying of 100 dia Heavy duty PVC Pipe with minimum of 1 mtr. excavation & refilling | BI01010001010000000000000515BI0100002361 | 10 | Rmt |
| 1245 | 367 | Supply and Laying of 2 core 1.00 Sq mm, copper, multi strand, armoured, overall PVC sheathed camera power cable as specified in the Tender Specifications | BI01010001010000000000000515BI0100002362 | 2500 | Rmt |
| 1246 | 368 | Supply and Laying of 4 core 1 Sq mm multi strand, copper, twisted pair, shielded, armoured, over all PVC sheathed PTZ camera data cable | BI01010001010000000000000515BI0100002363 | 1000 | Rmt |
| 1247 | 369 | Supply, Installation, Testing and Commssioining of 21\"color CCTV LCD monitor as specified in the Tender Specifications | BI01010001010000000000000515BI0100002364 | 5 | Nos |
| 1248 | 370 | Supply, Installation, Testing and Commissioining of PTZ Control Key board with joystick as specified in the Tender Specifications | BI01010001010000000000000515BI0100002365 | 2 | Lot |
| 1249 | 371 | Supply, Installation, Testing and Commssioining of 6 Mtrs high GI Pole for camera mounting including the civil works | BI01010001010000000000000515BI0100002366 | 6 | Nos |
| 1250 | 372 | Supplying, installing, testing and commissioning approved make 20 mm dia.MS flexible conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc. | BI01010001010000000000000515BI0100002367 | 100 | Rmt |
| 1251 | 373 | Supplying and fixing of perforated G.I.sheet cable tray with neccessory angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray is 40mm x 200mm x 40mm and 2mm thick. | BI01010001010000000000000515BI0100002368 | 250 | Rmt |
| 1252 | 374 | HVAC | BI01010001010000000000000515BI0100002369 | ||
| 1253 | 375 | AIR CONDITIONING WORKS | BI01010001010000000000000515BI0100002370 | ||
| 1254 | 376 | Supply, Installation, Testing & Commissioning & Handing over of the following: | BI01010001010000000000000515BI0100002371 | ||
| 1255 | 376.01 | All Sheet metal cabinet type double skin air handling units with listed thickness RPUF panels ( 50 mm thk) complete with Fan section with DIDW centrifugal fan(Backward type) direct driven fans, fan motor, single / Twin coil section (VRV ) along with vrv kits , Stainless drain pan, Filter section with Pre filter and Bag filter wiith set of spare & 1 set of commissioning filter apart from one assembled in the ahu LImit switch and Light will be provided in the fan section . There will be access door across every section of AHU. There will be opening for cable entries in AHU for blower section, MAKE-LG/DAIKIN/MITSUBISH/OGENERAL | BI01010001010000000000000515BI0100002372 | ||
| 1256 | 376.02 | The Air handling units shall be constructed using double-skinned acoustic panels with minimum 1.0 mm thick pre-coated GSS sheet for outer skin and & 1.2 mm plain GSS sheet for inner skin of the unit. All the panels shall incorporate 50 mm thick PUF insulation of density 40 Kg / cum and K factor not exceeding 0.02 W/ M deg C sandwiched in between inner & outer skin; the inner skins can be of perforated sheet in the case of Fan Sections to bring down the noise level.(refer technical spec for more details) | BI01010001010000000000000515BI0100002373 | ||
| 1257 | 376.03 | Heavy duct flexible double layer canvas connection shall be provided at the outlet of AHU Fan. Quoted price should be inclusive of Canvas Connections. | BI01010001010000000000000515BI0100002374 | ||
| 1258 | 376.04 | The variable frequency drive shall also be the part of the contract. VFD shall be supplied with IP 42 Protection. The price shall also include the cost of VFD with all relevant accessories as specified in the document. Cost of Panel with Starter with VFD should be considered by HVAC vendor scope. | BI01010001010000000000000515BI0100002375 | ||
| 1259 | 376.05 | VRV AHU'S | BI01010001010000000000000515BI0100002376 | ||
| 1260 | 376.06 | 50 TR capacity, 20000 Dcfm, VRV kit to be considered under part of scope. 50 mmwg fan external static, 6 row VRV cooling coil, Supply Air Plenum Section, filter sections with pre and bag filters , 1 set of spare & 1 set of commissioning filters.MAKE-ZECO,EDGSTECH | BI01010001010000000000000515BI0100002377 | ||
| 1261 | 376.07 | Supply & Installation of of Air Handling complete with all sections as specified above or technical specification | BI01010001010000000000000515BI0100002378 | 2 | Set |
| 1262 | 376.08 | Supply & Installation of double skin plenum of size 4000 mm x 1000 mm x 650 mm height | BI01010001010000000000000515BI0100002379 | ||
| 1263 | 376.09 | Supply & Installation of Stater Panel with VFD | BI01010001010000000000000515BI0100002380 | 2 | Set |
| 1264 | 376.1 | Supply & Installation of 1 set of Spare & Commissioning Filter. | BI01010001010000000000000515BI0100002381 | 2 | Set |
| 1265 | 376.11 | Power cables for outgoings from Starter Panels to AHU Motor - Supply & Installation of PVC insulated, cables, with copper conductor 1.1kV grade. | BI01010001010000000000000515BI0100002382 | ||
| 1266 | 376.12 | 3 C x 6 sq.mm AYFY / Suitable cable | BI01010001010000000000000515BI0100002383 | 30 | Rmt |
| 1267 | 376.13 | Supply & Installation of end termination for the above size calbe, including supply of SS double compression glands, solderless crimping type copper sockets. | BI01010001010000000000000515BI0100002384 | 2 | Nos |
| 1268 | 376.14 | Supply and providing GI earth tapes/wires clamped on the wall / run along with the cables as required of 8 SWG GI wire. | BI01010001010000000000000515BI0100002385 | 30 | Rmt |
| 1269 | 376.15 | 300 wide Perforated Cable Tray for above cables. | BI01010001010000000000000515BI0100002386 | 15 | Rmt |
| 1270 | 376.16 | AHU VRV KIT - for 60 HP (3 kits ) | BI01010001010000000000000515BI0100002387 | 3 | Set |
| 1271 | 377 | 12 TR capacity, 5000 Dcfm, VRV kit to be considered under part of scope. 50 mmwg fan external static, 6 row VRV cooling coil, Supply Air Plenum Section, filter sections with pre and bag filters , 1 set of spare & 1 set of commissioning filters. | BI01010001010000000000000515BI0100002388 | ||
| 1272 | 377.01 | Supply & Installation of of Air Handling complete with all sections as specified above or technical specification | BI01010001010000000000000515BI0100002389 | 4 | Set |
| 1273 | 377.02 | Supply & Installation of double skin plenum of size 4000 mm x 1000 mm x 650 mm height | BI01010001010000000000000515BI0100002390 | ||
| 1274 | 377.03 | Supply & Installation of Stater Panel with VFD | BI01010001010000000000000515BI0100002391 | 4 | Set |
| 1275 | 377.04 | Supply & Installation of 1 set of Spare & Commissioning Filter. | BI01010001010000000000000515BI0100002392 | 4 | Set |
| 1276 | 377.05 | Power cables for outgoings from Starter Panels to AHU Motor - Supply & Installation of PVC insulated, cables, with copper conductor 1.1kV grade. | BI01010001010000000000000515BI0100002393 | ||
| 1277 | 377.06 | 3 C x 6 sq.mm AYFY / Suitable cable | BI01010001010000000000000515BI0100002394 | 60 | Rmt |
| 1278 | 377.07 | Supply & Installation of end termination for the above size calbe, including supply of SS double compression glands, solderless crimping type copper sockets. | BI01010001010000000000000515BI0100002395 | 4 | Nos |
| 1279 | 377.08 | Supply and providing GI earth tapes/wires clamped on the wall / run along with the cables as required of 8 SWG GI wire. | BI01010001010000000000000515BI0100002396 | 60 | Rmt |
| 1280 | 377.09 | 300 wide Perforated Cable Tray for above cables. | BI01010001010000000000000515BI0100002397 | 60 | Rmt |
| 1281 | 377.1 | AHU VRV KIT - for 16 HP (1 kits ) | BI01010001010000000000000515BI0100002398 | 4 | Set |
| 1282 | 378 | 18 TR capacity, 7500 Dcfm, VRV kit to be considered under part of scope. 50 mmwg fan external static, 6 row VRV cooling coil, Supply Air Plenum Section, filter sections with pre and bag filters , 1 set of spare & 1 set of commissioning filters. | BI01010001010000000000000515BI0100002399 | ||
| 1283 | 378.01 | Supply & Installation of of Air Handling complete with all sections as specified above or technical specification | BI01010001010000000000000515BI0100002400 | 2 | Set |
| 1284 | 378.02 | Supply & Installation of double skin plenum of size 4000 mm x 1000 mm x 650 mm height | BI01010001010000000000000515BI0100002401 | ||
| 1285 | 378.03 | Supply & Installation of Stater Panel with VFD | BI01010001010000000000000515BI0100002402 | 2 | Set |
| 1286 | 378.04 | Supply & Installation of 1 set of Spare & Commissioning Filter. | BI01010001010000000000000515BI0100002403 | 2 | Set |
| 1287 | 378.05 | Power cables for outgoings from Starter Panels to AHU Motor - Supply & Installation of PVC insulated, cables, with copper conductor 1.1kV grade. | BI01010001010000000000000515BI0100002404 | ||
| 1288 | 378.06 | 3 C x 6 sq.mm AYFY / Suitable cable | BI01010001010000000000000515BI0100002405 | 60 | Rmt |
| 1289 | 378.07 | Supply & Installation of end termination for the above size calbe, including supply of SS double compression glands, solderless crimping type copper sockets. | BI01010001010000000000000515BI0100002406 | 4 | Nos |
| 1290 | 378.08 | Supply and providing GI earth tapes/wires clamped on the wall / run along with the cables as required of 8 SWG GI wire. | BI01010001010000000000000515BI0100002407 | 60 | Rmt |
| 1291 | 378.09 | 300 wide Perforated Cable Tray for above cables. | BI01010001010000000000000515BI0100002408 | 30 | Rmt |
| 1292 | 378.1 | AHU VRV KIT - for 10 HP (2 kits ) | BI01010001010000000000000515BI0100002409 | 2 | Set |
| 1293 | 379 | Indoor Unit(IDU): Cooling Only : | BI01010001010000000000000515BI0100002410 | ||
| 1294 | 379.01 | All the units should be supplied with Cordless remote control. The following Indoor unit capacities are required for the following areas: | BI01010001010000000000000515BI0100002411 | ||
| 1295 | 379.02 | Supply installation, testing & commissioning of below mentioned capacity of Ceiling concealed ductable type indoor,capable of varying the air volume as per requirement of the airconditioned space. | BI01010001010000000000000515BI0100002412 | ||
| 1296 | 379.03 | 4.66 TR / 1624 Cfm , 50mm ext static ductable type vrv indoor unit catering to vip suit, vip lounge , meeting room and dining room | BI01010001010000000000000515BI0100002413 | 2 | Set |
| 1297 | 379.04 | 2.6 TR / 883 Cfm , 50mm ext static ductable type vrv indoor unit catering to vip suit, vip lounge , meeting room and dining room | BI01010001010000000000000515BI0100002414 | 2 | Set |
| 1298 | 380 | VRV out door unit of following capacities :The VRV / VRF outdoor unit shall be equipped highly efficiency Hermetically sealed all inverter type scroll compressor(s) having at least 6 Pole motor.The outdoor unit needs to be equipped with at least 2 (TWO) compressors. The condenser fan should have minimum External Static Pressure of 75 Pa so as to avoid short cycling of hot air and refrigerant cooled PCB for enhanced reliability during peak temperature.The Outdoor unit must be capable of Varying the Refrigerant Temperature in order to work more efficiently .cop 3.7 at AHRI condition. Proposed out door unit should not derate the lobby capacity up to 39° c | BI01010001010000000000000515BI0100002415 | ||
| 1299 | 380.01 | OUT DOOR UNIT-01(24HP)- COMBINATION OF 12 HP x 2 NO'S FOR MULTIPURPOSE ROOM | BI01010001010000000000000515BI0100002416 | 1 | Set |
| 1300 | 380.02 | OUT DOOR UNIT-02(14HP)- for SEMINAR HALL -01 | BI01010001010000000000000515BI0100002417 | 1 | Set |
| 1301 | 380.03 | OUT DOOR UNIT-03(14HP)- for SEMINAR HALL -02 | BI01010001010000000000000515BI0100002418 | 1 | Set |
| 1302 | 380.04 | OUT DOOR UNIT-04(6HP)- for UPS ROOM | BI01010001010000000000000515BI0100002419 | 1 | Set |
| 1303 | 380.05 | OUT DOOR UNIT-05(6HP)- for UPS ROOM | BI01010001010000000000000515BI0100002420 | 1 | Set |
| 1304 | 380.06 | OUT DOOR UNIT-06(4HP)- for BATTERY ROOM | BI01010001010000000000000515BI0100002421 | 1 | Set |
| 1305 | 380.07 | OUT DOOR UNIT-07(4HP)- for BATTERY ROOM | BI01010001010000000000000515BI0100002422 | 1 | Set |
| 1306 | 380.08 | OUT DOOR UNIT-08(4HP)- for Green ROOM - LHS | BI01010001010000000000000515BI0100002423 | 1 | Set |
| 1307 | 380.09 | OUT DOOR UNIT-09(4HP)- for Green ROOM - RHS | BI01010001010000000000000515BI0100002424 | 1 | Set |
| 1308 | 380.1 | OUT DOOR UNIT-10(14HP)- for Below the Balocney area seating | BI01010001010000000000000515BI0100002425 | 1 | Set |
| 1309 | 380.11 | OUT DOOR UNIT-11(14HP)- for Below the Balocney area seating | BI01010001010000000000000515BI0100002426 | 1 | Set |
| 1310 | 380.12 | OUT DOOR UNIT-12- 60 HP (20HPX 3 NO'S )- for double height area | BI01010001010000000000000515BI0100002427 | 1 | Set |
| 1311 | 380.13 | OUT DOOR UNIT-12- 60 HP (20HPX 3 NO'S )- for double height area | BI01010001010000000000000515BI0100002428 | 1 | Set |
| 1312 | 380.14 | software for auto operation | BI01010001010000000000000515BI0100002429 | 1 | Set |
| 1313 | 381 | Suitable hard drawn copper piping for connecting the ahu coil to the out door units suitable pipe sizes to be selected.The suction & liquid line shall be insulated with 9 mm thick Sleeveless nitrile rubber insulation | BI01010001010000000000000515BI0100002430 | ||
| 1314 | 381.01 | suitable Copper piping | BI01010001010000000000000515BI0100002431 | 1200 | Rmt |
| 1315 | 382 | Imported Refnet joint to connect the above said pipes | BI01010001010000000000000515BI0100002432 | 40 | Set |
| 1316 | 383 | SHEET METAL WORKS | BI01010001010000000000000515BI0100002433 | ||
| 1317 | 383.01 | Sheet Metal Work with Ductmate Flanges for all sizes of the duct. Fabrication as per SMACNA Standards | BI01010001010000000000000515BI0100002434 | ||
| 1318 | 383.02 | Galvanizing shall be Class VII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. | BI01010001010000000000000515BI0100002435 | ||
| 1319 | 383.03 | All duct construction and installation shall be in accordance with SMACNA standards. In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. | BI01010001010000000000000515BI0100002436 | ||
| 1320 | 383.04 | All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. | BI01010001010000000000000515BI0100002437 | ||
| 1321 | 383.05 | The Duct shall be supported with Hi-tech Supports at regular intervals as mentioned in the technical specifications. The sheet metal ducting running in AHU Area should be supported with special acoustic hangers to avoid transmission of vibration from AHU Room to adjacent sensitive areas | BI01010001010000000000000515BI0100002438 | ||
| 1322 | 383.06 | 0.63 mm (24 Gauge) | BI01010001010000000000000515BI0100002439 | 3500 | Sqm |
| 1323 | 383.07 | 0.80 mm (22 Gauge) | BI01010001010000000000000515BI0100002440 | 250 | Sqm |
| 1324 | 383.08 | 1.00 mm (20 Gauge) | BI01010001010000000000000515BI0100002441 | 500 | Sqm |
| 1325 | 383.09 | 1.20 mm (18 Gauge) | BI01010001010000000000000515BI0100002442 | 50 | Sqm |
| 1326 | 384 | Air terminal Devices | BI01010001010000000000000515BI0100002443 | ||
| 1327 | 384.01 | Volume control Damper | BI01010001010000000000000515BI0100002444 | ||
| 1328 | 384.02 | Supply, installation, testing and commissioning of multiblade box type volume control damper of 16G Aluminum frame and 16G opposed type aerofoil blades for ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system , in accordance with technical specifications, for manual control of volume of air flow and for proper balancing of the air distribution system . | BI01010001010000000000000515BI0100002445 | 10 | Sqm |
| 1329 | 384.03 | Back Draft damper | BI01010001010000000000000515BI0100002446 | ||
| 1330 | 384.06 | Linear 150/100 mm wide grills in min 16 G extruded Aluminum Powder Coated construction with 0/15/30 deg deflection with end flanges, in accordance with technical specifications. | BI01010001010000000000000515BI0100002447 | 10 | Sqm |
| 1331 | 384.07 | Disc Valves in powder coated extruded Aluminum construction for Toilet Exhaust system suitable for 50 to 150 CFM with VCD | BI01010001010000000000000515BI0100002448 | 180 | Nos |
| 1332 | 384.08 | Fire/Smoke Damper with motorized actuator including control panel and sensor made out of min 16 G Galvanized steel frame and with opposed blades of min 16 G galvanized steel sheet as per the layout with UL 555 Certification for minimum 90 minutes rating. | BI01010001010000000000000515BI0100002449 | 6 | Sqm |
| 1333 | 384.09 | Non vision grille for toiles | BI01010001010000000000000515BI0100002450 | 5 | Sqm |
| 1334 | 385 | Jet Nozzle | BI01010001010000000000000515BI0100002451 | ||
| 1335 | 385.01 | 300 mm dia | BI01010001010000000000000515BI0100002452 | 40 | No |
| 1336 | 385.02 | 350 mm dia | BI01010001010000000000000515BI0100002453 | 40 | No |
| 1337 | 386 | Insulation | BI01010001010000000000000515BI0100002454 | ||
| 1338 | 386.01 | Supply & installation of Thermal insulation of the sheet metal duct with aluminum foil faced closed cell elastomeric insulation of Class 'O' material with density of 40 - 55 kg/cum as per the thickness mentioned below, with fire retardant adhesive and joints sealed with 3mm thick, 50mm wide nitrile rubber self adhesive tape all in accordance with technical specifications and with wrapping of fiber glass cloth & UV coating above the insulation properly finished and manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less than 0.2% water by volume. Adhesive shall be of low VOC preferably Fevicol ac duct king optima / equivalent. | BI01010001010000000000000515BI0100002455 | ||
| 1339 | 386.02 | 13 mm Thick | BI01010001010000000000000515BI0100002456 | 1600 | Sqm |
| 1340 | 387 | Supply, erection of Duct liner (Acoustic Insulation) of specified thickness of Open cell Elastromeric Rubber Insulation with antimicrobial protection manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume . Adhesive shall be of low VOC preferably Fevicol ac duct king optima / equivalent. | BI01010001010000000000000515BI0100002457 | ||
| 1341 | 387.01 | 9 mm Thick | BI01010001010000000000000515BI0100002458 | 1600 | Sqm |
| 1342 | 388 | VENTILATION UNITS | BI01010001010000000000000515BI0100002459 | ||
| 1343 | 388.01 | Supply, installation, testing and commissioning of ventilation units for the following sizes | BI01010001010000000000000515BI0100002460 | ||
| 1344 | 388.02 | Cabin type Exhaust air fan for pump room - 7500 cfm | BI01010001010000000000000515BI0100002461 | 1 | Set |
| 1345 | 388.03 | Cabin type Fresh air fan for pump room - 6000 cfm | BI01010001010000000000000515BI0100002462 | 1 | Set |
| 1346 | 388.04 | Cabin type Exhaust air fan for Toilet - LHS - 1800 cfm | BI01010001010000000000000515BI0100002463 | 2 | Set |
| 1347 | 388.05 | Cabin type Exhaust air fan for Toilet - RHS - 1800 cfm | BI01010001010000000000000515BI0100002464 | 2 | Set |
| 1348 | 388.06 | Cabin type Fresh air fan for Stair case Pressurization - 7500 cfm | BI01010001010000000000000515BI0100002465 | 4 | Set |
| 1349 | 388.07 | Cabin type Fresh air fan for Fire Lift Lobby Pressurization - 8000 cfm | BI01010001010000000000000515BI0100002466 | 2 | Set |
| 1350 | 388.08 | Cabin type Exhaust air fan for Electrical room - 5000 cfm | BI01010001010000000000000515BI0100002467 | 2 | Set |
| 1351 | 388.09 | Cabin type Fresh air fan for Electrical room - 3750 cfm | BI01010001010000000000000515BI0100002468 | 2 | Set |
| 1352 | 388.1 | Cabin type Exhaust air fan for Electrical room - 3750 cfm | BI01010001010000000000000515BI0100002469 | 2 | Set |
| 1353 | 388.11 | Cabin type Fresh air fan for Electrical room - 3000 cfm | BI01010001010000000000000515BI0100002470 | 2 | Set |
| 1354 | 388.12 | Cabin type Exhaust air fan for Toilet near the Green rooms - 5000 cfm | BI01010001010000000000000515BI0100002471 | 2 | Set |
| 1355 | 389 | Insulated Condesnate Drain Pipe | BI01010001010000000000000515BI0100002472 | ||
| 1356 | 390 | supply ,installation , testing and commissioning of following cpvc drain pipe with 9mm thick nitrile rubber insulation .. | BI01010001010000000000000515BI0100002473 | ||
| 1357 | 390.01 | 40 mm | BI01010001010000000000000515BI0100002474 | 200 | Rmt |
| 1358 | 390.02 | 32 mm | BI01010001010000000000000515BI0100002475 | 150 | Rmt |
| 1359 | 391 | MISC works | BI01010001010000000000000515BI0100002476 | ||
| 1360 | 392 | Providing of M.S. plate/channels, support for ducts etc. for ODU'S equipments as per Site condition | BI01010001010000000000000515BI0100002477 | 1500 | kg |
| 1361 | 393 | Closure of Opening all around ducts with Cement Motor & further covering all around the ducts with Fire Retardant Ceramic Wool spray / equvivalent material | BI01010001010000000000000515BI0100002478 | 15 | Sqm |
| 1362 | 394 | Supply, installation, testing and commissioning of Civil Foundation for following AHU units and VRF Outdoor unit. | BI01010001010000000000000515BI0100002479 | 1 | Lot |
| 1363 | 394.01 | Note : All electrical power & control cabling related to HVAC equipments except Power cabling to panel on electrical room and power cabling from Panel to isolator on in scope of HVAC contractor | BI01010001010000000000000515BI0100002480 | ||
| 1364 | 395 | LIFT | BI01010001010000000000000515BI0100002481 | ||
| 1365 | 395.01 | Supplying, installation ,testing and commissioning of machine room-less ( MRL)13Passenger(884 kg)lifts having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications. | BI01010001010000000000000515BI0100002482 | ||
| 1366 | 395.02 | Floor: LG+G+3 | BI01010001010000000000000515BI0100002483 | ||
| 1367 | 395.03 | Travel :14 Meters (approx) | BI01010001010000000000000515BI0100002484 | ||
| 1368 | 395.04 | Stops and Opening : 5Stops & 5 Opening | BI01010001010000000000000515BI0100002485 | ||
| 1369 | 395.05 | controller: ACD3-MRL | BI01010001010000000000000515BI0100002486 | ||
| 1370 | 395.06 | Automatic rescue device complete with dry maintenance free batteries as required | BI01010001010000000000000515BI0100002487 | ||
| 1371 | 395.07 | Operation: Microprocessor based single automatic push button / simplex selective collective / duplex selective collective/ with/ without attendant | BI01010001010000000000000515BI0100002488 | ||
| 1372 | 395.08 | power: 415V 3phase 50 HZ, 4-wire system | BI01010001010000000000000515BI0100002489 | ||
| 1373 | 395.09 | type of door: a. car: power operated center opening horizontal sliding, stainless steel scratch proof (moon rock finish) | BI01010001010000000000000515BI0100002490 | ||
| 1374 | 395.1 | b. landing doors: stainless steel scratch proof (moon rock finish) | BI01010001010000000000000515BI0100002491 | ||
| 1375 | 395.11 | A hand rail not less than 600mm long at 900 mm above floor level to be fixed adjacent to control panel in the lift car | BI01010001010000000000000515BI0100002492 | ||
| 1376 | 395.12 | Voice announcement system in the car to announce the position of the elevator in the hoist-way as the car passes or stops at a floor served by the elevator | BI01010001010000000000000515BI0100002493 | ||
| 1377 | 395.13 | Lift as per Above description complete as required. | BI01010001010000000000000515BI0100002494 | 4 | Set |
| 1378 | 396 | STAGE CRAFT,LIGHT & SOUND | BI01010001010000000000000515BI0100002495 | ||
| 1379 | 397 | OHM System Solution | BI01010001010000000000000515BI0100002496 | ||
| 1380 | 398 | Passive 2 x 8 inch mid / high speaker, Frequency Response: 55 Hz - 20 kHz (±3 dB), Continuous SPL: 130 dB/1m HF, Program SPL 133 dB/1m HF, Peak 136 dB/1 m HF. Continuous SPL: 119 dB/1m LF, Program SPL 122 dB/1m LF, Peak 125 dB/1 m LF. Power Handling: HF 100 Watts, LF 400 Watts cont. IEC268 AES, Maximum Power Handling: HF 200 Watt , LF 800 Watt prog. / HF 400 Watt , LF 1600 Watt peak, Impedance Nominal: HF 32 ohm / LF 32 ohm, Dispersion Nominal: 100° x 10° (hor. x vert.), or better. APPROVED MAKE- QSC,OHM, YAMAHA | BI01010001010000000000000515BI0100002497 | 4 | Pc |
| 1381 | 399 | Passive 2 x 8 inch mid / high speaker, Frequency Response: 55 Hz - 20 kHz (±3 dB), Continuous SPL: 130 dB/1m HF, Program SPL 133 dB/1m HF, Peak 136 dB/1 m HF. Continuous SPL: 119 dB/1m LF, Program SPL 122 dB/1m LF, Peak 125 dB/1 m LF. Power Handling: HF 100 Watts, LF 400 Watts cont. IEC268 AES, Maximum Power Handling: HF 200 Watt , LF 800 Watt prog. / HF 400 Watt , LF 1600 Watt peak, Impedance Nominal: HF 32 ohm / LF 32 ohm, Dispersion Nominal: 100° x 10° (hor. x vert.), or better. Approved Make: QSC, YAMAHA, OHM | BI01010001010000000000000515BI0100002498 | 4 | Pc |
| 1382 | 400 | Pasive 2 x 18 inch sub-woofer, Frequency Response: 29 Hz - 180 Hz (-10dB), 33 Hz - 160 Hz (±3 dB), Continuous SPL: 135 dB/1m, Program SPL 138 dB/1m, Peak 141 dB/1 m. Power Handling: 1250 Watt cont. IEC268 AES, Maximum Power Handling: 2500 Watt prog. / 5000 Watt peak, Impedance Nominal: 4 ohm, Dispersion Nominal: Omni (hor. x vert.). or better. QSC, YAMAHA, OHM | BI01010001010000000000000515BI0100002499 | 6 | Pc |
| 1383 | 401 | Passive 2 x 8 inch mid / high, Frequency Response: 69 Hz - 26 kHz (-10dB), 107 Hz - 25 kHz (±3 dB), Continuous SPL: 124.8 dB/1m, Program SPL 127.8 dB/1m, Peak 130.8 dB/1 m. Power Handling: 400 Watt cont. IEC268 AES, Maximum Power Handling: 800 Watt prog. / 1600 Watt peak, Impedance Nominal: 8 ohm, Dispersion Nominal: 160° x 40° (hor. x vert.) or better. Approved Make: OHM, QSC, YAMAHA | BI01010001010000000000000515BI0100002500 | 6 | Pc |
| 1384 | 402 | Passive 1 x 12 inch mid / high, Frequency Response: 75 Hz - 21 kHz (-10dB), 83 Hz - 20 kHz (±3 dB), Continuous SPL: 125 dB/1m, Program SPL 128 dB/1m, Peak 131 dB/1 m. Power Handling: 300 Watt cont. IEC268 AES, Maximum Power Handling: 600 Watt prog. / 1200 Watt peak, Impedance Nominal: 8 ohm, Dispersion Nominal: 90° x 40° (hor. x vert.) or better. Approved Make: QSC, OHM, YAMAHA | BI01010001010000000000000515BI0100002501 | 4 | Pc |
| 1385 | 403 | Passive 1 x 5.75 inch, Frequency Response: 90 Hz - 20 kHz (±3 dB), Continuous SPL: 102 dB, Peak SPL 108 dB. Power Handling: 60 Watt cont. IEC268 AES, Maximum Power Handling: 120 Watt prog. / 250 Watt peak, Impedance Nominal: 8 ohm, Dispersion Nominal: 100° x 100° (hor. x vert.) or better Approved Make: QSC, YAMAHA, OHM | BI01010001010000000000000515BI0100002502 | 2 | Pc |
| 1386 | 404 | Passive 1 x 5.75 inch, Frequency Response: 90 Hz - 20 kHz (±3 dB), Continuous SPL: 102 dB, Peak SPL 108 dB. Power Handling: 60 Watt cont. IEC268 AES, Maximum Power Handling: 120 Watt prog. / 250 Watt peak, Impedance Nominal: 8 ohm, Dispersion Nominal: 100° x 100° (hor. x vert.) or better.Approved Make: OHM. YAMAHA, QSC | BI01010001010000000000000515BI0100002503 | 2 | Pc |
| 1387 | 405 | Passive 1 x 4 inch, Frequency Response: 150 Hz - 20 kHz (±3 dB), Continuous SPL: 106 dB, Peak SPL 112 dB. Power Handling: 50 Watt cont. IEC268 AES, Maximum Power Handling: 100 Watt prog. / 200 Watt peak, Impedance Nominal: 16 ohm, Dispersion Nominal: 90° x 90° (hor. x vert.) or better. Approved Make: QSC, OHM, YAMAHA. | BI01010001010000000000000515BI0100002504 | 2 | Pc |
| 1388 | 406 | Speaker Mounting Hardware | BI01010001010000000000000515BI0100002505 | ||
| 1389 | 406.01 | Flying Frame for multiples of line array | BI01010001010000000000000515BI0100002506 | 2 | Pc |
| 1390 | 406.02 | Wall / Ceiling Cradle, complete with Handwheels | BI01010001010000000000000515BI0100002507 | 4 | Pc |
| 1391 | 406.03 | Wall / Ceiling Cradle, complete with Handwheels | BI01010001010000000000000515BI0100002508 | 2 | Pc |
| 1392 | 406.04 | Wall / Ceiling Cradle, complete with Handwheels | BI01010001010000000000000515BI0100002509 | 6 | Pc |
| 1393 | 407 | Audio Amplifiers | BI01010001010000000000000515BI0100002510 | ||
| 1394 | 407.01 | 2 Channel analog Amplifier, 2500 Watts @ 4 ohms, 1500 watts @ 8 ohms, 4400 watts @ 8 ohms bridged or better. Crown, British Acoustics, QSC | BI01010001010000000000000515BI0100002511 | 10 | Pc |
| 1395 | 407.02 | 2 Channel analog Amplifier, 1400 Watts @ 4 ohms, 700 watts @ 8 ohms, 3800 watts @ 8 ohms bridged or better. Approved Make: Crown, QSC, British Acoustics | BI01010001010000000000000515BI0100002512 | 1 | Pc |
| 1396 | 407.03 | 2 Channel analog Amplifier, 700 Watts @ 4 ohms, 350 watts @ 8 ohms, 1400 watts @ 8 ohms bridged or better. Approved Make: Crown, QSC, British Acoustics. | BI01010001010000000000000515BI0100002513 | 3 | Pc |
| 1397 | 408 | Digital Mixer | BI01010001010000000000000515BI0100002514 | ||
| 1398 | 408.01 | Digital Mixer: 24 Mic/Line, 3 Stereo Line, 4FX, 20 Mix, Touchscreen. Approved Make: Allen & Heath, Soundcraft, Yamaha. | BI01010001010000000000000515BI0100002515 | 1 | Pc |
| 1399 | 408.02 | AudioRack for digital mixers: 24 Mic/Line, 12 XLR Out, Cat5.Approved Make: Allen & Heath, Soundcraft, Yamaha | BI01010001010000000000000515BI0100002516 | 1 | Pc |
| 1400 | 408.03 | 100m CAT5 cable with EtherCon locking connectors | BI01010001010000000000000515BI0100002517 | 1 | Pc |
| 1401 | 408.04 | Unified Series Core with 24 local I/O channels, 128x128 network I/O channels, dual LAN ports, telephone POTS, 16x16 GPIO, 16 AEC channels, 1RU. Approved Make: QSC, DBX, OHM. | BI01010001010000000000000515BI0100002518 | 2 | Pc |
| 1402 | 409 | Audio Source | BI01010001010000000000000515BI0100002519 | ||
| 1403 | 410 | Professional CD player with USB. Approved Make: Sony, LG, Samsung. | BI01010001010000000000000515BI0100002520 | 1 | Pc |
| 1404 | 411 | Microphones | BI01010001010000000000000515BI0100002521 | ||
| 1405 | 412 | SITC of a wireless RF handheld microphone system with a super cardiod capsule and mute switch and RF output power at 50 O that shall be switchable between 10 mW / 30 mW / 50 mW operating within UHF frequency ranges, of 470 – 558 MHz and 718 – 790 MHz with a switching bandwidth of up to 88 MHz ; receiving frequencies shall be 3520 per range and shall be tunable in 25 kHz steps, featuring 20 fixed frequency banks with up to 32 compatible frequency presets and 6 user banks with up to 32 user programmable frequencies and receiver shall have an Ethernet port (RJ-45) for remote network-based monitoring and control. Sensitivity shall be < 2 µV for 52 dBA eff S/N. Signal-to-noise ratio at 1 mV and peak deviation shall be = 115 dBA. THD shall be = 0.9 % and audio output level can be adjustable within a 48 dB range in steps of 3 dB. Audio frequency response shall range from 80 – 18,000 Hz and Signal-to-noise ratio at 1 mV and peak deviation shall be = 115 dBA and input sensitivity shall be adjustable within a 48 dB range in steps of 6 dB. Nominal voltage shall be 2.4 V and current consumption shall be typical 180 mA at nominal voltage. Approved Makes: Sennheiser, Clock Audio, Clearone. | BI01010001010000000000000515BI0100002522 | 6 | Pc |
| 1406 | 413 | SITC of a wireless RF lavalier microphone system with omni directional capsule with RF output power at 50 O that shall be switchable between 10 mW / 30 mW / 50 mW and operating within UHF frequency ranges of 470 – 558 MHz and 718 – 790 MHz, with a switching bandwidth of up to 88 MHz ; receiving frequencies shall be 3520 per range and shall be tunable in 25 kHz steps featuring 20 fixed frequency banks with up to 32 compatible frequency presets and 6 user banks with up to 32 user programmable frequencies and receiver shall have an Ethernet port (RJ-45) for remote network-based monitoring and control with sensitivity < 2 µV for 52 dBA eff S/N, THD shall be = 0.9 % and audio output level can be adjustable within a 48 dB range in steps of 3 dB. Audio frequency response between 80 – 18,000 Hz (microphone) or 25 - 18,000 Hz (line). Signal-to-noise ratio at 1 mV and peak deviation shall be = 115 dBA and input sensitivity shall be adjustable within a 60 dB range in steps of 3 dB. Nominal voltage shall be 2.4 V, current consumption shall be typical 180 mA at nominal voltage. Approved Makes: Sennheiser, Clock Audio, Clearone. | BI01010001010000000000000515BI0100002523 | 1 | Pc |
| 1407 | 414 | SITC of active antenna splitter 2× 1:4 or 1× 1: Frequency range: 470 – 870 MHz at –3 dB, 23 dBm typical Impedance 50 ? Reflection loss 10 dB (all RF outputs) Power consumption : 245 mA Total power consumption Max. 2A (4 receivers & 2 × 2 antenna amplifiers per antenna input) Approved Makes: Sennheiser, Clock Audio, Clearone\n | BI01010001010000000000000515BI0100002524 | 3 | Pc |
| 1408 | 415 | SITC of directional antenna with Impedance:50 Ohm; Connector: BNC; Pick-up pattern: directional;Frequency range: 450 - 960 MHz ;Antenna gain: 4 dBi ;Opening angle: +- 50 degrees ; Approved Makes: Sennheiser, Clock Audio, Clearone | BI01010001010000000000000515BI0100002525 | 2 | Pc |
| 1409 | 416 | SITC of antenna booster Approved Makes: Sennheiser, Clock Audio, Clearone | BI01010001010000000000000515BI0100002526 | 2 | Pc |
| 1410 | 417 | SITC of dynamic cardioid vocal microphone with frequency response of 40 Hz – 16,000 Hz and the sensitivity of 2.7 mV/Pa at 1 kHz, nominal impedance of 350 Ohm, with a min. terminating impedance of 1 k Ohm. Approved Makes: Sennheiser, Clock Audio, Rode\n | BI01010001010000000000000515BI0100002527 | 4 | Pc |
| 1411 | 418 | SITC of pre-polarized condenser gooseneck microphone with an overall length of minimum 450 mm and with XLR3M-type connector at its base, which shall offer radio frequency interference (RFI) shielding against intermodulation from wireless equipment or devices, cardioid microphone capsule with uniform 120° angle of acceptance (-3dB) or better, frequency response of 50 Hz to 20,000 Hz or better and sound input levels handling capability of minimum 130 dBspl, nominal equivalent noise level of 26 Dba or better and output shall be low impedance balanced (<100 ohms) with current consumption shall be 3 mA or better. Approved Makes: Sennheiser, Clock Audio, Clearone, Rode | BI01010001010000000000000515BI0100002528 | 1 | Pc |
| 1412 | 419 | SITC of table stand for connecting and operating XLR gooseneck microphones shall be rugged and unobtrusive with XLR-3F microphone input and an XLR-3M microphone output operating on 48 V phantom power and current consumption of 3.7 mA or better. Approved Makes: Sennheiser, Clock Audio, Clearone, Rode | BI01010001010000000000000515BI0100002529 | 1 | Pc |
| 1413 | 420 | SITC of super-cardioid pre-polarized condenser instrument microphone with frequency response of 40 Hz- 20,000 Hz and sensitivity of 3 mV/P at 1 kHz, Maximum SPL of 139 dB at 1 kHz. Nominal impedance of 50 Ohm, with a min. terminating impedance of 1 kOhm. Approved Makes: Sennheiser, Clock Audio, Rode | BI01010001010000000000000515BI0100002530 | 4 | Pc |
| 1414 | 421 | SITC of microphone set consisting of steel drum case; 1 nos dynamic cardioid microphone with an integral stand mount, fitted with a hum compensating coil for low frequency instruments with frequency response of 20 Hz – 16,000 Hz and the sensitivity (free field, no load) of 0.25 mV/Pa at 1 kHz and 0.9 mV/Pa at 50 Hz, nominal impedance of 350 ?, with a min. terminating impedance of 1 k?; \n4 nos dynamic cardioid instrument microphone for drums and percussion as well as brass and woodwind instruments featuring an integral stand mount and hum compensating coil with frequency response of 40 Hz – 18,000 Hz and the sensitivity (free field, no load) of 1.8 mV/ Pa at 1 kHz. nominal impedance of 350 ?, with a min. terminating impedance of 1 k?; \n2 nos super-cardioid pre-polarized condenser instrument microphone with frequency response of 40 Hz- 20,000 Hz and sensitivity of 3 mV/P at 1 kHz, Maximum SPL of 139 dB at 1 kHz. Nominal impedance of 50 Ohm, with a min. terminating impedance of 1 kOhm. Approved Makes: Sennheiser, Clock Audio, Rode | BI01010001010000000000000515BI0100002531 | 1 | Pc |
| 1415 | 422 | Cables & Connectors | BI01010001010000000000000515BI0100002532 | ||
| 1416 | 422.01 | 2.5 square mm, 4 core, speaker cable or better. Approved Make: Belden, Lynq, Krystal | BI01010001010000000000000515BI0100002533 | 500 | Mtr |
| 1417 | 422.02 | 4 square mm, 2 core, speaker cable or better. Approved Make: Belden, Lynq, Krystal | BI01010001010000000000000515BI0100002534 | 300 | Mtr |
| 1418 | 422.03 | 2.5 square mm, 2 core, speaker cable or better. Approved Make: Belden, Lynq, Krystal | BI01010001010000000000000515BI0100002535 | 200 | Mtr |
| 1419 | 422.04 | Microphone Cable. Approved Make: Belden, Lynq, Krystal | BI01010001010000000000000515BI0100002536 | 500 | Mtr |
| 1420 | 422.05 | XLR Male Connector. Approved Make: Belden, Neutrik, Krystal | BI01010001010000000000000515BI0100002537 | 80 | Pc |
| 1421 | 422.06 | XLR Female Connector. Approved Make: Belden, Neutrik, Krystal | BI01010001010000000000000515BI0100002538 | 80 | Pc |
| 1422 | 422.07 | Speakon Connector. Approved Make: Belden, Neutrik, Krystal | BI01010001010000000000000515BI0100002539 | 100 | Pc |
| 1423 | 422.08 | Mono Jack Connectors. Approved Make: Belden, Neutrik, Krystal | BI01010001010000000000000515BI0100002540 | 12 | Pc |
| 1424 | 422.09 | Phono RCA Connectors. Approved Make: Belden, Neutrik, Krystal | BI01010001010000000000000515BI0100002541 | 8 | Pc |
| 1425 | 423 | Accessories | BI01010001010000000000000515BI0100002542 | ||
| 1426 | 423.01 | Microphone Stand (Big) | BI01010001010000000000000515BI0100002543 | 6 | Pc |
| 1427 | 423.02 | Microphone Stand (Smalll) | BI01010001010000000000000515BI0100002544 | 6 | Pc |
| 1428 | 423.03 | 24U Rack | BI01010001010000000000000515BI0100002545 | 3 | Pc |
| 1429 | 424 | ISCT | BI01010001010000000000000515BI0100002546 | ||
| 1430 | 424.01 | Installation Servicing Testing and Commisioning | BI01010001010000000000000515BI0100002547 | 1 | Pc |
| 1431 | 424.02 | SITC of 8\" Two-way full range loudspeaker; Woofer size : 8\", Tweeter size : 1\"; Low impedance : 8 ?; Low impedance dynamic power : 300W; SPL 1W/1m : 90dB; Max SPL : 112dB Frequency response : 60 - 20K Hz; V X H dispersion @ 1KHz : 160° X 150°; Woofer cone material : Paper ; IP rating : 40; Construction Material : MDF Wood Approved makes : APART-AUDIO / OHM / QSC | BI01010001010000000000000515BI0100002548 | 12 | Nos |
| 1432 | 424.03 | SITC of Eight Channel Digital Power amplifier,\n8 x 250Watts @ 4?, Bridgeable to 4 X\n500Watts @ 8 Ohm; Power Amp Topology :\nClass D, Convection cooled, Hypex Inside,\nPower Supply : SMPS; Protection Circuit : Over\nCurrent, Over temperature; Frequency\nresponse : 20 - 22KHz; S/N ratio : > 100 dB AWeighted; THD : <0.5% A Weighted; 2U 19\"\nrackmount\nApproved makes : APART-AUDIO / OHM /\nQSC | BI01010001010000000000000515BI0100002549 | 2 | Nos |
| 1433 | 424.04 | SITC of wireless digital Handheld Microphone with 18 or more channel, RF output 100mW or more, super cardiod pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ45, Battery backup : 17 or more hr etc and complete as required. Approved Makes : Sennheiser / Shure / Revolab. | BI01010001010000000000000515BI0100002550 | 2 | Nos |
| 1434 | 424.05 | SITC of wireless digital lavalier Microphone with 18 or more channel, RF output 100mW or more, omni directional pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ-45, Battery backup : 17 or more hr etc and complete as required | BI01010001010000000000000515BI0100002551 | 2 | Nos |
| 1435 | 424.06 | SITC of wireless microphone charging dock station from the same make. Approved Makes : Sennheiser / Shure / Revolab | BI01010001010000000000000515BI0100002552 | 4 | Nos |
| 1436 | 424.07 | SITC of Mixer : On-board processors SPX algorithm: 6 programs , I/O Phantom power +48 V , Mono[MIC/LINE]2 ; Stereo[LINE] 2 ; STEREO OUT 2; PHONES 1 ; Bus Stereo: 1. Approved Make: YAMAHA/SOUNDCRAFT/ALLEN&HEATH. | BI01010001010000000000000515BI0100002553 | 2 | Nos |
| 1437 | 424.08 | BlueCore Laser with 360 °projection, DLP Single 0.47\" WUXGA, DC3 DMD Chip, 5000 AL, 3000,000:1 contrast, Native 16:10 (5 aspect ratio selectable), zoom 1.1x, focus & V+H lens shift2D keystonene, 10W speakers, Digital Shrink and Shift, Image Memory, Projector/ Remote Control ID Setting, Auto High Altitude Mode, HDBaseT, LAN Control, 360°Projection, DustProof Filter- Anti-Dust IP5X DustGuard, multiple screen applications, 3 years onsite on projector. 3 years or 15,000 hours on Laser Light* or better. Approved Make: NEC/BENQ/SONY | BI01010001010000000000000515BI0100002554 | 2 | Pc. |
| 1438 | 424.09 | Projector Screen 200\"Diagonal. Approved Make: dalite/Altop/Dapper. | BI01010001010000000000000515BI0100002555 | 2 | Pc. |
| 1439 | 425 | SITC of Digital Podium Lectern Table - 19” rack type Wooden (in Silver or Wooden Color) Body - Durable Steel (Black Color) Drawer for storing small accessories Sliding Tray to protect your Tablet Monitor Keyboard sliding tray & Horizontal tray for mouse Interactive 19” Touch Monitor Electromagnetic Tablet Monitor Touch Protection Technology 1280 x 1024 (SXGA) Resolution High Response Speed Gooseneck Microphone Premium Quality Audio & High Fidelity, Cardioid Polar Pattern 9 ~ 52 Phantom Power Supply Digital Visualiser Portable Type Light weight, standalone type Multimedia All-in-One Controller PC1200 Control LCD/DLP projector, Motorized screen, DVD, VCR, VIS, Visualizer etc Compatible with most multimedia devices Digital volume adjustment control function Integrated Matrix Switcher (AV Matrix, VGA Switch module) Multimedia Speakers Multi-Function Power Amplifier 3 MIC Inputs, 2 AUX Inputs and 1 AUX Output for connection Muting Function Individual Volume Control Amplifier with Remote Out Control and Phantom Power . Approved Make: Comm/AHA/ Dalite. | BI01010001010000000000000515BI0100002556 | 2 | Pc. |
| 1440 | 425.01 | 2.5 square mm, 2 core, speaker cable or better. Approved Make: Belden, Lynq, Krystal | BI01010001010000000000000515BI0100002557 | 1 | Lot |
| 1441 | 425.02 | 12U audio visual Rack with all accessories. Approved Make:Valrack, WQ, Heinrich. | BI01010001010000000000000515BI0100002558 | 2 | Pc |
| 1442 | 425.03 | Projector Ceiling Kit. Approved Make: Suvira/Altop/Dalite | BI01010001010000000000000515BI0100002559 | 2 | Pc |
| 1443 | 425.04 | Supply, Installation,Testing and Commisioning of Audio, Cable laying, Conduits. | BI01010001010000000000000515BI0100002560 | 1 | Nos |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail