Construction Of Building For Dtpc Thiruvananthapuram, Vellayambalam Trivandrum-Kerala

Wapcos Limited has published Construction Of Building For Dtpc Thiruvananthapuram. Submission Date for this Tender is 10-08-2020. Building Work Tenders in Vellayambalam Trivandrum Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

24860742
Corrigendum : Construction Of Building For Dtpc Thiruvananthapuram
Open Tender
Indian
Kerala
Vellayambalam Trivandrum
10-08-2020

Tender Details

Construction Of Building For Dtpc Thiruvananthapuram

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Jul-2020 Corrigendum-1 Date 03-08-2020
2 04-Aug-2020 Corrigendum 2 Date 10-08-2020

Key Value

Document Fees
INR 2800 /-
EMD
INR 50000.0 /-
Tender Value
INR 64.46 Lakhs /-

BOQ Items

Work Name : Construction of Building for DTPC, Thiruvananthapuram
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11CIVIL WORKBI01010001010000000000000515BI0100001113
21.012.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI0100001114142.494cum
31.022.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.BI01010001010000000000000515BI0100001115105.26cum
41.0350.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-chargeBI01010001010000000000000515BI010000111668.575cum
51.044.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI01000011179.616cum
61.057.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)BI01010001010000000000000515BI010000111821.474cum
71.065.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeBI01010001010000000000000515BI010000111923.195cum
81.075.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000112044.807cum
91.085.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001121217.475sqm
101.095.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platformBI01010001010000000000000515BI0100001122426.143sqm
111.15.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI01000011232319.5kilogram
121.115.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI01000011244480.7kg
131.1250.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.BI01010001010000000000000515BI010000112595.321cum
141.1350.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc completeBI01010001010000000000000515BI01000011266.472cum
151.1413.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)BI01010001010000000000000515BI01000011271050.53sqm
161.1513.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)BI01010001010000000000000515BI010000112893.841sqm
171.1613.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plasterBI01010001010000000000000515BI0100001129163.657sqm
181.1713.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)BI01010001010000000000000515BI0100001130356.327sqm
191.184.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000113114.045cum
201.1922.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.BI01010001010000000000000515BI010000113213.275sqm
211.29.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak woodBI01010001010000000000000515BI01000011332.212cum
221.219.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shuttersBI01010001010000000000000515BI010000113422.262sqm
231.229.7.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Float glass panes4 mm thick glass paneBI01010001010000000000000515BI010000113538.075sqm
241.2313.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)BI01010001010000000000000515BI01000011361500.7sqm
251.2413.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.BI01010001010000000000000515BI01000011371500.7sqm
261.2513.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqmBI01010001010000000000000515BI0100001138263.689sqm
271.2613.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI01000011391237.01sqm
281.2713.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI0100001140102.937sqm
291.2811.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.BI01010001010000000000000515BI010000114165.109sqm
301.2911.40 : Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.BI01010001010000000000000515BI010000114213.275sqm
311.311.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.BI01010001010000000000000515BI0100001143181.303sqm
321.319.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mmBI01010001010000000000000515BI010000114430.002metre
331.329.120.1 : Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shuttersBI01010001010000000000000515BI010000114510.081sqm
341.338.2.2.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqmBI01010001010000000000000515BI010000114642.542sqm
351.348.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite workBI01010001010000000000000515BI010000114772.201metre
361.3510.3 : Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer .BI01010001010000000000000515BI01000011482.861sqm
371.3610.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipesBI01010001010000000000000515BI0100001149433.99kg
381.3713.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel workBI01010001010000000000000515BI010000115019.92sqm
391.3816.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.BI01010001010000000000000515BI010000115115sqm
401.3916.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)BI01010001010000000000000515BI01000011521.05cum
411.412.45.1 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1BI01010001010000000000000515BI010000115329.5sqm
421.4112.53 : Providing and Fixing 15 mm densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone /cosmos /Hexa or equivalent of size 595x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross \"T\" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main 'T' of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid, including cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main 'T' runners to be suspended from ceiling using G.I slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm, spaced at 1200mm centre to centre along main 'T' bottom exposed with 24 mm of all T- sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), light reflection > 85% non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity < 0.043 w/m 0 KC.BI01010001010000000000000515BI010000115418sqm
431.429.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etcBI01010001010000000000000515BI010000115538.075kg
441.43od77784/2019_2020 : Providing and fixing fixed glass window of thickness 12 mm with all fittings etc complete and as per the direction of the Engineer in charge.BI01010001010000000000000515BI01000011569.88sqm
451.449.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000115770each
461.459.62.1 : Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete:300x16 mmBI01010001010000000000000515BI010000115811no
471.469.95.2 : Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:125x63x4 mmBI01010001010000000000000515BI010000115948no
481.479.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mmBI01010001010000000000000515BI010000116024no
491.489.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mmBI01010001010000000000000515BI010000116122no
501.499.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopperBI01010001010000000000000515BI010000116222no
511.59.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.BI01010001010000000000000515BI010000116311each
521.5110.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.BI01010001010000000000000515BI010000116411each
531.5210.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubesBI01010001010000000000000515BI0100001165967.788kg
541.5317.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lidBI01010001010000000000000515BI01000011666each
551.5417.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.BI01010001010000000000000515BI01000011676each
561.5518.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal boreBI01010001010000000000000515BI01000011682each
571.5618.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.BI01010001010000000000000515BI01000011692000Litre
581.5718.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal boreBI01010001010000000000000515BI01000011706each
591.5818.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal boreBI01010001010000000000000515BI010000117120each
601.5918.64 : Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms.BI01010001010000000000000515BI01000011726no
611.618.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.BI01010001010000000000000515BI010000117312each
621.6118.74.1 : Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collar and bush approved quality and colour .15 mm nominal bore with 30 cm lengthBI01010001010000000000000515BI010000117412each
631.6217.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tapBI01010001010000000000000515BI01000011756each
641.6317.28.2.1 : Flexible pipe32 mm diaBI01010001010000000000000515BI01000011766each
651.6417.34.1 : Providing and fixing toilet paper holder:C.P. brassBI01010001010000000000000515BI01000011776no
661.6517.73.1 : Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gmsBI01010001010000000000000515BI010000117812no
671.6650.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.BI01010001010000000000000515BI01000011796no
681.6750.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wallBI01010001010000000000000515BI010000118060metre
691.6850.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wallBI01010001010000000000000515BI010000118160metre
701.6950.18.7.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wallBI01010001010000000000000515BI010000118260metre
711.750.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2BI01010001010000000000000515BI0100001183100metre
721.7150.18.9.22.3 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door ElbowBI01010001010000000000000515BI010000118418no
731.7250.18.9.22.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia BendBI01010001010000000000000515BI010000118518no
741.7350.18.9.22.6 : Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door teeBI01010001010000000000000515BI010000118618no
751.7451.19.ST4 : Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br>\n4. 35 to 50 flush capacityBI01010001010000000000000515BI01000011871each
761.7519.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5BI01010001010000000000000515BI01000011886each
771.76od77805/2019_2020 : Providing and laying vertified anti skid floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.BI01010001010000000000000515BI010000118911.5sqm
781.77od77809/2019_2020 : Providing and fixing multipurpose Cement board (high pressure steam cured) as per IS 14862, with suitable screws for fibre cement board in ceiling etc. complete (frame work to be paid separately) , 9mm thick cement board.BI01010001010000000000000515BI010000119044.3per sqm
791.78od77815/2019_2020 : Providing and fixing roofing shingles over E board of specific thickness including cost of adhesive, labour and conveyance charges.BI01010001010000000000000515BI010000119144.3per sqm
802ELECTRICALBI01010001010000000000000515BI0100001192
812.011.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group CBI01010001010000000000000515BI010000119375point
822.021.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.BI01010001010000000000000515BI01000011944point
832.031.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mmBI01010001010000000000000515BI0100001195980metre
842.041.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mmBI01010001010000000000000515BI0100001196725metre
852.051.17.14 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mmBI01010001010000000000000515BI0100001197120metre
862.061.17.23 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mmBI01010001010000000000000515BI0100001198210metre
872.071.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mmBI01010001010000000000000515BI010000119985metre
882.081.17.32 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. mmBI01010001010000000000000515BI010000120067metre
892.091.18.3 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 PairBI01010001010000000000000515BI0100001201465metre
902.11.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.BI01010001010000000000000515BI0100001202265metre
912.111.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mmBI01010001010000000000000515BI01000012031325metre
922.121.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mmBI01010001010000000000000515BI0100001204665metre
932.131.22.1 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deepBI01010001010000000000000515BI010000120510each
942.141.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outletBI01010001010000000000000515BI01000012065each
952.151.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outletBI01010001010000000000000515BI01000012074each
962.161.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).BI01010001010000000000000515BI010000120866each
972.171.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.BI01010001010000000000000515BI010000120923each
982.181.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outletBI01010001010000000000000515BI010000121012each
992.191.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outletBI01010001010000000000000515BI01000012115each
1002.21.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell pushBI01010001010000000000000515BI01000012126each
1012.212.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCBBI01010001010000000000000515BI01000012131each
1022.222.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double doorBI01010001010000000000000515BI01000012142each
1032.232.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleBI01010001010000000000000515BI010000121588each
1042.242.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neturalBI01010001010000000000000515BI01000012163each
1052.252.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple poleBI01010001010000000000000515BI01000012174each
1062.262.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000012182each
1072.272.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000012191each
1082.282.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsBI01010001010000000000000515BI01000012202each
1092.292.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000012212each
1102.32.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000012221each
1112.312.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsBI01010001010000000000000515BI01000012232each
1122.322.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required.BI01010001010000000000000515BI01000012244each
1132.332.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 30 amps \"C\" curve, TPMCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.BI01010001010000000000000515BI01000012252each
1142.345.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.BI01010001010000000000000515BI01000012262set
1152.355.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)BI01010001010000000000000515BI010000122747metre
1162.365.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.BI01010001010000000000000515BI0100001228125metre
1172.377.3.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation and refilling the trench etc as required, but\nexcluding sand cushioning and protective covering.Upto 35 sq. mmBI01010001010000000000000515BI010000122957metre
1182.387.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)BI01010001010000000000000515BI0100001230185metre
1192.397.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)BI01010001010000000000000515BI010000123155metre
1202.49.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 35 sq. mm (32mm)BI01010001010000000000000515BI01000012322set
1212.419.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 70 sq. mm (38mm)BI01010001010000000000000515BI01000012332set
1222.429.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 16 sq. mm (28mm)BI01010001010000000000000515BI01000012344set
1232.439.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 25 sq. mm (28mm)BI01010001010000000000000515BI01000012354set
1242.4490.5.1.5 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.BI01010001010000000000000515BI01000012362each
1252.45od71750/2019_2020 : Supply ,Laying and clamping of earth strip/wire inclusive of providing earth termination and bracing of termination etc. No 10 CU wireBI01010001010000000000000515BI0100001237440metre
1262.46od71751/2019_2020 : LIGHT FITTING AND FANS..LINEAR GENERAL PURPOSE LUMINAIRES. Supplying and fixing following SLEEK RD- surface mounted or recessed Round or Square Down light 112545 BGSLO Sleek surface 18W WH RD cool white LED down light fo soft diffused lighting complete light out put on ceiling / wall including connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cable etc as required (Make Philips,Crompton Greeves.)testing and commissioningBI01010001010000000000000515BI010000123863each set
1272.47od71752/2019_2020 : Supply, Installation, Testing &amp; Commissioning of deco batten type1x20W LED Type Tube Light design channel light out put on ceiling / wall including connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cable etc.(including lamp) as required (Make Philips,Crompton Greeves.)BI01010001010000000000000515BI01000012395each set
1282.48od71753/2019_2020 : Supply, installation, testing and commisioning of following sweep ceiling fan, including wiring the down rods of standard length (upto 30 cm t0 100cm) with 1.5 sq. mm FR PVC insulated, copper condutor, single core cable etc. as required. (a) 1200 mm sweep ceiling fan white shade with stepped type electronic fan regulator OR 400mm 3 Blade Wall fan(Usha (Striker)/,Crompton(High breeze)/ Havells (Velocity))BI01010001010000000000000515BI010000124013each set
1292.49od71754/2019_2020 : Supply, installation, testing and commissioning of following exhaust fan in the exisitng opening, including making the hole to suit the size of the above fan, making good damage, connection, testing, commisioning etc. as required. (a) 230 mm (Make:- Almonard - light duty)BI01010001010000000000000515BI010000124114each set
1302.5od71755/2019_2020 : Supply and fixing of Angle holder or pendent type with 9w LED lamp.Including Lamp Shade.BI01010001010000000000000515BI010000124214each set
1312.51od71756/2019_2020 : Supply, Assembling, installation, testing &amp; commisioning of BULK HEAD with 9W LED BULB including all other acessories etc as required. (philips or equivalent)BI01010001010000000000000515BI01000012437each
1322.52od71757/2019_2020 : LED pendant narrow luminaires - 20W range. Supplying and fixing following completeStandalone suspended sleek luminaire for asthetically appealing downlighting.Suspension of 1.5 mtr is included&lt;br&gt;(02 nos.) 112232 BPTXn 20W LED 4F NW Neutral White with connections, testing and commissioning etc. as&lt;br&gt;required.BI01010001010000000000000515BI01000012447each set
1332.53od71758/2019_2020 : Supply Erection Installation Testing and Commissioning of LED Street lights 2o w (Havells, Bajaj, CG, Dewton etc.).(Including all connecting items. IP66BI01010001010000000000000515BI01000012454each
1342.54od71759/2019_2020 : KSEB METER BOARD.. Fabrication, supply erection testing and commissioning of metering board with dust and vermin,weather proof, made out of 16 swg Powder coated CRCA sheet. The board should be chemically treated and coated with two coats of metal primer and two coats of siemens grey enamel paints. including HRC Fuse link, 160A SFU WITH 4numbers CT Provision including CT. Appro. size.....or fiber type Provision for three phase meter(KSEB) - 1Sets. including handles , all connecting items fuses etc..,.160A HRC Fuse 3NOS or GRP,Fiber Type depend on the site conditionBI01010001010000000000000515BI01000012461each set
1352.55od71760/2019_2020 : LED BOLLARDS&lt;br&gt;Flute. Supplying and fixing following completeLED Bollard in Cylindrical shape with opal acrylic di user and IP 66 protection111282 BGBOL 605 9W LED with connections, testing and commissioning etc. as required.&lt;br&gt;Details of cost for one eachp to the terminal block. Ingress protection : IP 66BI01010001010000000000000515BI01000012474each
1362.56od71761/2019_2020 : Change over Switch Fabrication, supply erection testing and commissioning of change over switch with dust and vermin,weather proof, made out of 16 swg Powder coated CRCA sheet. The board should be chemically treated and coated with two coats of metal primer and two coats of siemens grey enamel paints. including 160A Change over switch connections etc as required. or GRP,Fiber Type depend on the site conditionBI01010001010000000000000515BI01000012481each
1372.57od71763/2019_2020 : Safety Items. Supply and installation of 5KG ABC type fire extinguishers having ISI mark along with mounting supportsBI01010001010000000000000515BI01000012494each
1382.58od71765/2019_2020 : Supply of 70 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPEBI01010001010000000000000515BI010000125024metre
1392.59od71767/2019_2020 : Supply of 35 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPEBI01010001010000000000000515BI010000125125metre
1402.6od71768/2019_2020 : Supply of 25 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPEBI01010001010000000000000515BI010000125284metre
1412.61od71769/2019_2020 : Supply of 16 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPEBI01010001010000000000000515BI010000125375metre
1422.62od71770/2019_2020 : Supply of 6 sqmm 3 core PVC/XLPE insulated armoured cable with copper conductors for working Voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPEBI01010001010000000000000515BI010000125457metre
1432.63od71771/2019_2020 : Supplying and fixing 40 amps to 63 Amps Three Pole rating,415 volts, `C&apos; Curve , miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required . 63 amps three PoleBI01010001010000000000000515BI01000012552each
1442.64od71772/2019_2020 : Supplying and fixing 40 amps to 63 Amps Three Pole rating,415 volts, `C&apos; Curve , miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required . 40 amps three PoleBI01010001010000000000000515BI01000012562each
1452.65od71773/2019_2020 : Supply installation testing &amp; commissioning of 8Ways Vertical DBs- Provision for TP MCCB (V-TEC) N2 Frame up to 125A in 16kA, 25kA as Incomer. IP : 43 Protection, Shrouded Neutral Bus Bar &amp; Pan assembly with flexible connected link, Cement Spill Protector, Door Earthing. INDOASIAN or same spec havells ,legrand, abb, l&amp;t..BI01010001010000000000000515BI01000012571each set
1462.66od71774/2019_2020 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including&lt;br&gt;earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double doorBI01010001010000000000000515BI01000012583each
1472.67od71776/2019_2020 : Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB &amp; KSEL including all laison works for getting energisation sanction (Actual will be reimbursed on production of original reciepts.)BI01010001010000000000000515BI01000012591each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail