| 1 | 1 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified. | | 744.8 | Sqm |
|---|
| 2 | 2 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. | | 12 | Cum |
|---|
| 3 | 3 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified. | | 1060 | Sqm |
|---|
| 4 | 4 | Supply and fixing , decorative hollow PVC sheet 8-9 mm thick fixed to wall panelling with self drilling screws as per manufacturing instruction and complete all as specified and directed. | | 180 | Sqm |
|---|
| 5 | 5 | Supply and fixing, 12mm thick Perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with screws to timber frame work or with staples on snap grid complete all as specified and directed. | | 360 | Sqm |
|---|
| 6 | 6 | Supply and fixing GI snap grid work 605 x 605 mm frmae work for false ceiling including necessary supporting hanger with 6 mm dia GI wire (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long, complete all as specified and as directed. | | 520 | Sqm |
|---|
| 7 | 7 | Supply and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufactures instructions, complete all as specified and as directed. | | 520 | Sqm |
|---|
| 8 | 8 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4, complete all as specified. | | 12 | Cum |
|---|
| 9 | 9 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. | | 56.71 | Qtl |
|---|
| 10 | 10 | Fabrication, erection and fixing only (material retrieved under Srl item no 09 shall be reused) rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified. | | 4271 | Kg |
|---|
| 11 | 11 | S & F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified. | | 1400 | Kg |
|---|
| 12 | 12 | S & F mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length of bolt exc 15cm and n exc 22.5 cm long, diameter of shank 12 mm complete all as specified and directed. | | 75 | Kg |
|---|
| 13 | 13 | M & L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. | | 16.8 | Sqm |
|---|
| 14 | 14 | M & L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. | | 728 | Sqm |
|---|
| 15 | 15 | Preparation new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint of colour as approved by GE over a coat of red oxide primer complete all as specified. | | 17 | Sqm |
|---|
| 16 | 16 | Preparation old treated steel surfaces of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint of colour as approved by GE complete all as specified. | | 143 | Sqm |
|---|
| 17 | 17 | M&L for preparation of old treated wooden surfaces exceeding 10 cms width or girth and applying one coats of synthetic enamel paint complete all as specified. | | 52 | Sqm |
|---|
| 18 | 18 | Taking down cement plaster or cement line plaster on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified. | | 745 | Sqm |
|---|
| 19 | 19 | 15mm thick rendering in cement mortar 1:6 on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified | | 365 | Sqm |
|---|
| 20 | 20 | 15mm thick rendering in cement mortar 1:4 on fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified | | 380 | Sqm |
|---|
| 21 | 21 | M & L preparation of new plastered surfaces of walls and applying two coats cement base paint of approved brand and colour as approved by GE over a coat of chalk whiting all as specified and as directed . | | 380 | Sqm |
|---|
| 22 | 22 | M & L preparation of new plastered surface of wall and applying a coat of chalk whiting and two coat of distemper oil emusion complete all as specified | | 365 | Sqm |
|---|
| 23 | 23 | M&L Applying one coat of white wash including preparation of old decorated or unplastered surfaces of ceiling including cornices, pilasters by brooming down or steel wire brushing, scrapping down, smoke soot moulds, moss and efflorescent salts and greasy spots and complete all as specified and directed by Engineer-in-Charge | | 510 | Sqm |
|---|
| 24 | 24 | M&L Applying one coat of oil bound distemper including preparation of old decorated or unplastered surfaces ofwall including cornices, pilasters by brooming down or steel wire brushing, scrapping down, smoke soot moulds, moss and efflorescent salts and greasy spots and complete all as specified and directed by Engineer-in-Charge\n | | 834 | Sqm |
|---|
| 25 | 25 | M&L removal of existing treatement of walls and applying two coat of cement base paint over a coat of primer on walls all complete and as directed. | | 1210 | Sqm |
|---|
| 26 | 26 | Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specified and directed.\n | | 183 | Per\nPoint |
|---|
| 27 | 27 | M&L Point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings, including 1.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. \nNote : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (b) On RCC roof ceiling PVC conduit shall be provided on surface for fan with proper fixing clips all as directed. | | 103 | Per\nPoint |
|---|
| 28 | 28 | All as per above item no 27 here in before but for one 3 pin socket outlet 5 amp on independent board all as specified and directed. | | 40 | Per\nPoint |
|---|
| 29 | 29 | All as per above item no 27 here in before but for one 3 pin socket outlet 5 amp on same board all as specified and directed. | | 6 | Per\nPoint |
|---|
| 30 | 30 | All as per above item no 27 here in before but for one bell/buzzer point controlled by one bell push button on same board with other switch or independentwith cable 1.5 Sqmm size all as specified and directed. | | 4 | Per\nPoint |
|---|
| 31 | 31 | M&L Point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings on independent board including 2.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. \nNote : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) | | 30 | Per\nPoint |
|---|
| 32 | 32 | M&L Switch piano flush type 5 Amp single pole one way, (ISI marked), complete all as specified. | | 109 | Each |
|---|
| 33 | 33 | M&L Socket outlet 2 in 1, 5 Amp flush type all as specified & directed. | | 6 | Each |
|---|
| 34 | 34 | M&L Switch Socket combintion outlet 2 & 3 pin, 5 Amp flush type ,complete all as specifed. | | 40 | Each |
|---|
| 35 | 35 | M&L Switch Socket combintion outlet 2 in 1 , 5 pin, 15 Amp flush type universal,complete all as specifed. | | 30 | Each |
|---|
| 36 | 36 | S&F Switch bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified | | 4 | Each |
|---|
| 37 | 37 | S & F Ceiling rose, 65x50mm three therminals isolated body (ISI marked) complete all as specified.\n | | 61 | Each |
|---|
| 38 | 38 | S & F LED Tube light fitting 20 watt , 230 volts,box type complete with bipin holders,connector block and retro LED rod of 20 Watt, 4 feet long with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser having high efficacy (double side connection) complete with all accessories internally prewired batten (double side connection) and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings ,complete all as specified and directed. \nNote: (i) Contractor shall produce LM 79 & LM 80 test report form OEM owned NABL accredited laboraory. \n(ii) Contractor shall give gurantee of complete fitting/ fixtures for minimum of 2 years form the date of completion.\n(iii) Contractor shall conduct the inspection of company representative at site before installation of fittings/fixtures at no extra cost.\n(iv) Contractor shall arrange arrange 70% material at site for approval of GE before incorporation in the work. | | 40 | Each Job |
|---|
| 39 | 39 | S&F in replacement wall LED light 25 Watt (with one no. extra driver + surge protector) including brackets and fixing arrangement with clamps , necessary nuts, bolts and washers etc , connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed. \n | | 12 | Each Job |
|---|
| 40 | 40 | S&F in replacement LED recess mounting powder coated white CRCA full glow panel 45 watt 2 x 2 feet incoporated with all fixing arrangement complete with accessories internally prewired and including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed. \n | | 30 | Each Job |
|---|
| 41 | 41 | Taking down ceiling fan/exhaust/wall mounting fan of any make & sweep from exiting position of any height and carrying out cleaning and servicing and refixing in existing/new location after repair work of bldg and connecting up with new flexible twin core copper conducto cable all as specified and directed. | | 21 | Each Job |
|---|
| 42 | 42 | S& F bell Ding Dong heavy duty 230 volts single pole complete and all as specified. all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 43 | 43 | S&F in replacement sheet metal enclosure powder coated VTPN DB factory made versatile double door 4 way for fixing MCCB 63 Amp , 415 volts, 50 Hz, with 200 amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, complete all as specified. \n | | 4 | Each |
|---|
| 44 | 44 | S & F MCCB four pole 415 volts 63 amps with breaking capacity 25 KA with thermal setting and copper lugs, all as specified and as directed by Engr -in-Charge. | | 4 | Each |
|---|
| 45 | 45 | S&F Sheet metal enclosure powder coated factory made (Double door) for DBs, single pole and neutral, 240 volts, 50 Hz, 04 way with 200 amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, complete all as specified. \n | | 2 | Each |
|---|
| 46 | 46 | S&F Sheet metal enclosure powder coated factory made (Double door) for DBs, single pole and neutral, 240 volts, 50 Hz, 08 way with 200 amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, complete all as specified. \n | | 8 | Each |
|---|
| 47 | 47 | S&F Sheet metal enclosure powder coated factory made (single door) for DBs, single pole and neutral, 240 volts, 50 Hz, 02 way with 200 amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, complete all as specified. \n | | 12 | Each |
|---|
| 48 | 48 | S & F MCB single pole & neutral 240 volts 63 Amps 'C' curve with rupturing capacity 10 KA, all as specified and as directed by Engr -in-Charge. | | 22 | Each |
|---|
| 49 | 49 | S & F MCB single pole 240 volts 6 to 32 Amps 'C' curve with rupturing capacity 10 KA, all as specified and as directed by Engr -in-Charge. | | 52 | Each |
|---|
| 50 | 50 | S & F MCB single pole & neutral 240 volts 40 Amps 'C' curve with rupturing capacity 10 KA, all as specified and as directed by Engr -in-Charge. | | 22 | Each |
|---|
| 51 | 51 | Supply and laying in repairs of existing circuit/submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 6 sqmm drawing into and including concealed PVC rigid non metallic conduit of 25mm dia and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 6 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed.\nNote: Two runs of 6 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 6 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 25mm dia wiil be measured as a one unit. | | 500 | RM |
|---|
| 52 | 52 | Supply and laying in repairs of existing circuit/submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 10 sqmm drawing into and including concealed PVC rigid non metallic conduit of 25mm dia and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 10 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed.\nNote: Two runs of 10 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 10 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 25mm dia wiil be measured as a one unit. | | 120 | RM |
|---|
| 53 | 53 | Supply and laying in repairs of existing circuit/submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 4 x 10 sqmm drawing into and including concealed PVC rigid non metallic conduit of 25mm dia and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 2 x 10 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed.\nNote: Four runs of 10 Sqmm single core PVC insulated copper conductor cable(FRLS) and two run of 10 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 25mm dia wiil be measured as a one unit. | | 120 | RM |
|---|
| 54 | 54 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). | | 4 | Each\nSet |
|---|
| 55 | 55 | Supply laying jointing and testing LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm 3.5 core complete all as specified. \n | | 110 | RM |
|---|
| 56 | 56 | Supply laying jointing and testing LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 3.5 core complete all as specified. \nNotes for Srl item No 55 & 56 : Earth work , sand cushioning, GI pipe , brick covering for mechanical protection will be measured and paid separately under respective item of Schedule. | | 229 | RM |
|---|
| 57 | 57 | Taking out the old unsv existing cable of any size in trenches or passing through pipe/fixed on pole to pole/wall including disconnecting from supplyall as specified and directed. | | 339 | RM |
|---|
| 58 | 58 | S&F DWC high density polyethelene pipes in replacement having 63/50outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed. Make -Trupati /Equivalent | | 240 | RM |
|---|
| 59 | 59 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation laying poles, stay assembly and laying of LT/HT cables in any type of soil and getting out, complete all as specified. | | 70 | Cum |
|---|
| 60 | 60 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed. | | 67 | Cum |
|---|
| 61 | 61 | Removal of excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed | | 3 | Cum |
|---|
| 62 | 62 | Material and labour earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in electrical plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) and dismantling old defective earthpit. | | 2 | Each\nset |
|---|
| 63 | 63 | Supply & fixing in replacement of rusted feeder pillar box (KIOSK) with and including fabrication of double and outdoor type incorporated with bus bar chamber having with aluminium busbar capacity 400 amps insulated with RYB & black PVC Insulated tape suitable for 415 Votls 3 Phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS Sheet not less than 3.15 mm thick also having provision for incoming/outgoing COS/cables. 02 Nos earth terminal point complete with 10 mm bolt, 02 nos nuts and 02 Nos wahsers 3 mm thick complete earth. The panel body must be painted with power coated paint after the complete 7 tanks dip process to remove all impurities from the panel sheet all the door must be fixed with detachable pin type hinges steel door locking system, all the electrical connection inside the panel from bus bar to MCCBs, shall be through aluminium strip property insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5 mm duly painted with two coat of synthetic enamelled balck paint over a coat of red oxide primer all as specified and directed and comprising of the folowing items.\n(i) MCCB 200 Amps 36 KA rating 4 pole 415 volts- 01 No (In coming)\n(ii) MCCB 100 Amps 25 KA rating 3 pole 415 volts- 01 No (Out coming)\n(iii) MCB SPN 40 Amps-02 Nos.\n | | 1 | Each\nJob |
|---|
| 64 | 63.01 | (iv) RYB LED indicator lamp-03 Nos\n(v) Digital volt meter with selector switch 0-500 Volt-01 Nos\n(vi) Platform for feeder pillar box with PCC 1:2:4 type B 1 using 20 mm graded crushed stone aggregate, 15 cm thick in foundation, brick( sub class B ) work in cement mortar 1:6 , rendering 10 mm thick in cement mortar 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C 1 using 20 mm graded crushed stone aggregate as in padding on top and panel legs 40 cm grouted and 90 cm above the ground level\nNote :- MCCB's shall be fixed in independent position , Main bus bar in step way, the depth of the panel be less than 350 mm , All the rates deemed to be included in the cost of the job. No extra cost shall be paid, before placing the order drawings shall be approved by the GE and shall be kept in record.\n | | | |
|---|
| 65 | 64 | Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum. | | | |
|---|