| 1 | 1 | Excavation over areas n exc 1.5 m deep and getting out in soft/disintegrated rock for foundation. all as specified and directed by Engr in charge. | 10 | 150 | Cum |
|---|
| 2 | 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil. | 11 | 38.2 | Cum |
|---|
| 3 | 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock | 12 | 12.38 | Cum |
|---|
| 4 | 4 | M & L cement concrete type B2, 1:2:4 (using 40 mm graded aggregate) as in foundation for posts/struts etc. | 13 | 19 | Cum |
|---|
| 5 | 5 | M & L cement concrete in foundation filling and mass concrete type D2, 1:4:8 (using 40 mm graded aggregate) | 14 | 6 | Cum |
|---|
| 6 | 6 | M & L of hard core of gauge exc 63 mm but n exc 100mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface. | 15 | 60 | Cum |
|---|
| 7 | 7 | M&L 50mm thick sand filling under floors or in foundations including watering and consolidation. | 16 | 30 | Cum |
|---|
| 8 | 8 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment all as specified and directed by Engr in charge. | 17 | 600 | Sqm |
|---|
| 9 | 9 | S & F roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angles, channel or flat sections) including distance pieces, cleats etc. (Fe- 410-W (Gde E-250 quality A) | 18 | 5000 | Kg |
|---|
| 10 | 10 | M&L for preparation of new steel surfaces and apply two coat of Anti corrossive paint over a coat of anti corresive primer. | 19 | 380 | Sqm |
|---|
| 11 | 11 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, cladding to wall fixed with self tapping screws as specified . | 20 | 500 | Sqm |
|---|
| 12 | 12 | M & L pre cast cement concrete block masonry with solid block masonry type C-1, 1:3:6 (using 20mm graded aggregate) exc 10cm in width and setting and jointed in cement mortar 1:6 all as specified and directed. | 21 | 44 | Cum |
|---|
| 13 | 13 | M & L 15 mm thick rendering on PCC block masonry surfaces in cement mortar 1:6 finishing the surfaces even and smooth without using extra cement. | 22 | 180 | Sqm |
|---|
| 14 | 14 | M & L two coats of cement based paint over a coat of alkali resistant primer including preparation of new plastered surfaces. | 23 | 180 | Sqm |
|---|
| 15 | 15 | Removing excavated rock/soil exc 50m but not exc 250m and depositing where directed at a level n exc 1.5 m above the starting point. | 24 | 181 | Cum |
|---|
| 16 | 16 | S&F Mild steel work as in angle, Flat iron, etc for posts, struts in fencing including embedded in concrete and screwing etc, cutting tops to shape as directed, drilling holes, notching for wire , etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similiar work confirming to Fe 290-Gde E-165. | 25 | 5000 | Kgs |
|---|
| 17 | 17 | S&F Mild steel screw bolts (Machine made) with hexagonal /square heads at one end and screwed the other/screwed both ends, each screwd end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long dia of neck 11 to 15 mm. | 26 | 75 | Kgs |
|---|
| 18 | 18 | M&L Concertina coil 610 mm dia, 125 to 127 clips per coil, 50 circles of wire in each coil (coil coverage of 6-8 RM and weight approx 8.5 Kg per coil) GI Wire, GI clips, GI pins and fixed on top of compound wall with angle iron brackets all as specified. (Note :- Angle iron brackets will be measured and paid separately) | 27 | 510 | Kg |
|---|
| 19 | 19 | Supply and fixing Mild steel round bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips hanging door fitting and hanging including welding etc also fastening and fixing complete confirming to grade Fe-410 W (Gde E-250) quality A. | 28 | 750 | Kg |
|---|
| 20 | 20 | Supply and fixing PVC coated MS galvanised wire chain link fencing of any type of standard, rail straining bolts etc including provision of binding wire complete all as specified and directed by Engr-in-Charge. | 29 | 1600 | Kg |
|---|
| 21 | 21 | Supply, Laying, joining & testing LT XLPE Insulated & sheathed armoured electric cables with multistranded aluminium conductor cable 1100 volts grade, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes & aluminium lugs for connection for cross- sectional area 6 Sq mm 2 Core complete all as specified and directed. | 30 | 110 | RM |
|---|
| 22 | 22 | Supply and laying PCC cable cover class LV type 1 flat size 250mmx150mmx40mm | 31 | 420 | Each |
|---|
| 23 | 23 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil. | 32 | 11.2 | CUM |
|---|
| 24 | 24 | Removal of soft/disintegrated rock to a distance not exceeding 50 m and depositing where directed by Engr-in-charge. | 33 | 8.37 | CUM |
|---|
| 25 | 25 | Supply and fixing GI tubing (light grade) with all fittings,laid in trenches, or fixed along with walls /poles,bore of pipe 40mm (light grade). | 34 | 10 | RM |
|---|
| 26 | 26 | Material and labour for point wiring complete as specified with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FR grade, conforming to relevant IS, drawn through and including PVC casing and caping with all accessories fixed on surfaces of wall, ceiling, including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor cable FR grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for One light point controlled by one switch. | 35 | 12 | Per point |
|---|
| 27 | 27 | Supply & fixing switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete. | 36 | 12 | Each |
|---|
| 28 | 28 | Supply & Fixing ceiling rose, surface Bakelite 65x50 mm Two to three terminals. | 37 | 12 | Each |
|---|
| 29 | 29 | Supply and fixing 25W 4ft long LED batten light fitting with 2.5 KV voltage surge protection ,PF >0.9 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size . | 38 | 12 | Each |
|---|
| 30 | 30 | M&L for earthing complete with GI steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including necessary earth work and excavation of in any type of strata, PCC 1:3:6 type C-2 GI tubing 20 mm dia for watering and 15mm dia GI tubing for protection of wire etc all as per electrical plate No.5 of SSR part I including connecting to electrical equipments and testing on completion. | 39 | 4 | Each |
|---|
| 31 | 31 | Supply & Fixing SPN DB one way without busbar. | 40 | 3 | Each |
|---|
| 32 | 32 | Supply & Fixing SPN MCB 01 Amp,230 Volts. | 41 | 3 | Each |
|---|
| 33 | 33 | M/L for fine river sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment | 42 | 6.48 | Cum |
|---|