| 1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | | | |
|---|
| 2 | 1.01 | Group -A | BI01010001010000000000000515BI0100001127 | 48 | POINT |
|---|
| 3 | 1.02 | Group -B | BI01010001010000000000000515BI0100001128 | 23 | POINT |
|---|
| 4 | 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | | | |
|---|
| 5 | 2.01 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | BI01010001010000000000000515BI0100001130 | 99 | METRE |
|---|
| 6 | 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001131 | 35 | METRE |
|---|
| 7 | 4 | Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amp socket outlet and 15/16 amp piano type switch, connection, painting etc. as required. | BI01010001010000000000000515BI0100001132 | 4 | EACH |
|---|
| 8 | 5 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required.( For AC) | BI01010001010000000000000515BI0100001133 | 1 | EACH |
|---|
| 9 | 6 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 Pair | BI01010001010000000000000515BI0100001134 | 7 | METRE |
|---|
| 10 | 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. A) 20 mm | BI01010001010000000000000515BI0100001135 | 5 | METRE |
|---|
| 11 | 8 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required | | | |
|---|
| 12 | 8.01 | a) 75 mm X 75 mm X 60 mm deep | BI01010001010000000000000515BI0100001137 | 1 | EACH |
|---|
| 13 | 8.02 | b) 150 mm X 75 mm X 60 mm deep | BI01010001010000000000000515BI0100001138 | 21 | EACH |
|---|
| 14 | 9 | Supplying and fixing following Piano type switch/ socket on the existing switch box/ cover including connections etc. as required. | | | |
|---|
| 15 | 9.01 | 5/6 A switch | BI01010001010000000000000515BI0100001140 | 31 | EACH |
|---|
| 16 | 9.02 | 3 pin 5/6 A socket outlet | BI01010001010000000000000515BI0100001141 | 31 | EACH |
|---|
| 17 | 9.03 | Telephone Socket outlet | BI01010001010000000000000515BI0100001142 | 1 | EACH |
|---|
| 18 | 10 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | BI01010001010000000000000515BI0100001143 | 21 | EACH |
|---|
| 19 | 11 | Supplying and fixing PVC batten/ angle holder including connection etc. as required | BI01010001010000000000000515BI0100001144 | 5 | EACH |
|---|
| 20 | 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including\nearthing etc. as required. (But without MCB/RCCB/Isolator) | | | |
|---|
| 21 | 12.01 | 6 way double door | BI01010001010000000000000515BI0100001146 | 2 | EACH |
|---|
| 22 | 13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | | | |
|---|
| 23 | 13.01 | SINGLE POLE (6 Amp-23, 16 Amp-5) | BI01010001010000000000000515BI0100001148 | 28 | EACH |
|---|
| 24 | 13.02 | DOUBLE POLE 32 AMP | BI01010001010000000000000515BI0100001149 | 12 | EACH |
|---|
| 25 | 14 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required | BI01010001010000000000000515BI0100001150 | 12 | SET |
|---|
| 26 | 15 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001151 | 4 | SET |
|---|
| 27 | 16 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. \n | BI01010001010000000000000515BI0100001152 | 85 | METRE |
|---|
| 28 | 17 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required | BI01010001010000000000000515BI0100001153 | 48 | METRE |
|---|
| 29 | 18 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. | BI01010001010000000000000515BI0100001154 | 4 | EACH |
|---|
| 30 | 19 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required | BI01010001010000000000000515BI0100001155 | 14 | EACH |
|---|
| 31 | 20 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) | BI01010001010000000000000515BI0100001156 | 30 | METRE |
|---|
| 32 | 21 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required | BI01010001010000000000000515BI0100001157 | 4 | EACH |
|---|
| 33 | 22 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (2 x 25 sq mm) | | | |
|---|
| 34 | 22.01 | a) 2 x 6 sq mm) | BI01010001010000000000000515BI0100001159 | 20 | EACH |
|---|
| 35 | 22.02 | b) 2 x 16 sq mm) | BI01010001010000000000000515BI0100001160 | 4 | EACH |
|---|
| 36 | 22.03 | c) 3.5 x 25 sq mm) | BI01010001010000000000000515BI0100001161 | 4 | EACH |
|---|
| 37 | 23 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. | BI01010001010000000000000515BI0100001162 | 7 | EACH |
|---|
| 38 | 24 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | | | |
|---|
| 39 | 24.01 | 4 way double door | BI01010001010000000000000515BI0100001164 | 10 | EACH |
|---|
| 40 | 25 | Supplying, Installation, testing and commissioning of 20 watt LED batten with polycarbonate housing & integrated electronic driver, box type etc. as required including making connection etc. as required directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required | BI01010001010000000000000515BI0100001165 | 4 | EACH |
|---|
| 41 | 26 | Supplying & laying of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV Grade of size 2X6 Sq. MM conf to IS: 7098 (Part-I) direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. | BI01010001010000000000000515BI0100001166 | 658 | METRE |
|---|
| 42 | 27 | Supplying & laying of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV Grade of size 2X16 Sq. MM conf to IS: 7098 (Part-I) direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. | BI01010001010000000000000515BI0100001167 | 120 | METRE |
|---|
| 43 | 28 | Supplying & laying of one number XLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 3.5 X 25 Sq. MM conf to IS: 7098 (Part-I), direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. | BI01010001010000000000000515BI0100001168 | 80 | METRE |
|---|
| 44 | 29 | Supplying & laying of one number XLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 2X6 Sq. MM conf to IS: 7098 (Part-I) in the existing METAL PIPE / OPEN as required. | BI01010001010000000000000515BI0100001169 | 92 | METRE |
|---|
| 45 | 30 | Supplying & laying of one number XLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 2X16 Sq. MM conf to IS: 7098 (Part-I) in the existing METAL PIPE / IN OPEN as required. | BI01010001010000000000000515BI0100001170 | 24 | METRE |
|---|
| 46 | 31 | Supplying & laying of one number XLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 3.5 X 25 Sq. MM conf to IS: 7098 (Part-I) in the existing METAL PIPE / IN OPEN as required. | BI01010001010000000000000515BI0100001171 | 20 | METRE |
|---|
| 47 | 32 | Supplying and Laying of one number additional XLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 2 X 6 Sq. MM conf to IS: 7098 (Part-I) direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. | BI01010001010000000000000515BI0100001172 | 175 | METRE |
|---|
| 48 | 33 | Supplying and fixing G. I. pipe of 40 mm dia (medium duty) for protection of UG cable of ISI marked. | BI01010001010000000000000515BI0100001173 | 81 | METRE |
|---|
| 49 | 34 | Supplying and fixing of 40 mm dia (light duty) G. I. pipe for mounting of ceiling fans etc.as required | BI01010001010000000000000515BI0100001174 | 27 | METRE |
|---|
| 50 | 35 | Supplying and fixing Fan Hook / Clamps suitable for mounting 900/1200 / 1400 mm sweep ceiling fan etc. as equired. | BI01010001010000000000000515BI0100001175 | 7 | EACH |
|---|
| 51 | 36 | Supplying and fixing of 380 mm sweep, heavy duty, exhaust fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing opening including making the hole to suit the size of above exhaust fan & S/F of louver / shutter including connection, testing and making connection with 1.5 sq.mm., FRLS, PVC insulated, copper conductor, single core cable and earthing etc. as required etc as required of ISI marked. | BI01010001010000000000000515BI0100001176 | 4 | EACH |
|---|
| 52 | 37 | Supplying and fixing 6 watt slim surface mounted round LED down light cool white, aesthetically designed Aluminum housing enclosure with constant driver including making connection etc. as required. | BI01010001010000000000000515BI0100001177 | 34 | EACH |
|---|
| 53 | 38 | Supplying and fixing bulk head fitting, die cast aluminium alloy body, diffuser, heat resistant prismatic glass cover with specially designed gesket and providing & fixing of 9 watt LED lamp including making connection etc. as required. | BI01010001010000000000000515BI0100001178 | 11 | EACH |
|---|
| 54 | 39 | Supplying and fixing of 16 watt CMRI cerified LED flameproof tube light fitting with IP65 protection including making connection etc. as required. | BI01010001010000000000000515BI0100001179 | 1 | EACH |
|---|
| 55 | 40 | Supplying and fixing of 15 watt LED street light fitting including Supplying and fixing of 32 mm dia G.I pipe (medium duty) bracket of 0.75 mtr length bend to required shape on existing wall by suitable clamping arrangement for installation of the fitting etc. as required. | BI01010001010000000000000515BI0100001180 | 2 | EACH |
|---|
| 56 | 41 | Supplying and fixing of 30 Watts Circular LED Flood with innovative finless design and excellent thermal management and light distribution along with IP66 protection includind making connections etc.as required. | BI01010001010000000000000515BI0100001181 | 5 | EACH |
|---|
| 57 | 42 | Supplying of 09 watt LED lamp. | BI01010001010000000000000515BI0100001182 | 5 | EACH |
|---|
| 58 | 43 | S/ITC of outdoor type feeder piller, double door made out of 14 SWG CRCA sheet of size 1000 mm x 500 mm x 300 mm deep having 100 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires, & angle iron frame of size 900 mm x 350 mm with 600 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required. | BI01010001010000000000000515BI0100001183 | 2 | EACH |
|---|
| 59 | 43.01 | i) 63 Amps, 4 pole, MCCB , breaking capacity 25/30 kA at 415 volts, 50 Hz AC supply = 01 No. | | | |
|---|
| 60 | 43.02 | ii) 63 Amps, 4 pole, 415 volts, 50 Hz SDFU = 01 No. | | | |
|---|
| 61 | 43.03 | iii) 32 Amp, DP, MCB, 10 KA, C curve, 240 V, 50 Hz = 05 Nos. | | | |
|---|
| 62 | 44 | Add cost index on DSR2018 [email protected]% on 01 to 22 (Rs 226619) | BI01010001010000000000000515BI0100001188 | 1 | Fixed |
|---|