| Name of Work: Construction of Auditorium building at Sunaria Distt Rohtak | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | HSR (CIVIL PART) | BI01010001010000000000000515BI0100001112 | ||
| 2 | 2 | Earth work in excavation in all kinds of soil, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs.(HSR no. 6.6) CP(425%) | BI01010001010000000000000515BI0100001113 | 548.95 | %Cum |
| 3 | 3 | Earth work in excavation in foundations, trenches Of under ground structures sullage drains, etc., and Other similar works in ordinary soild including Dressing of bottom and sides, to correct levels and templates, cutting Of trees and bushes, dewatering of rain water, diversion of traffic, fixing And maintenance of caution boards, and night singnals, crossing over Trenches for access to houses, watching stacking of excavated soil, clear, From the edge of excavation, and subsequent filling, where required around Masonry, in 15 cm layers, with compaction and disposal of surplus Soil as directed within a lead of 30 metres for depth upto 2 METRES BELOW NATURAL GROUND LEVEL (For Public Health works only) (HSR 6.7) CP 370% | BI01010001010000000000000515BI0100001114 | 228.53 | %Cum |
| 4 | 4 | Clearing grass and removal of the rubbish upto distance of outside the periphery of the area cleared. HSR 6.27 (CP @ 370%) | BI01010001010000000000000515BI0100001115 | 2656.94 | %Sqm |
| 5 | 5 | Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing (HSR 8.5) CP 550% (b)In cement | BI01010001010000000000000515BI0100001116 | 3.5 | Cum |
| 6 | 6 | reinforced cement concrete with cleaning and straghtening and cutting of bars if required. (HSR 8.6) CP 550% (e) reinforced cement concrete with cleaning and straghtening and cutting of bars if required. | BI01010001010000000000000515BI0100001117 | 26.68 | Cum |
| 7 | 7 | Shuttering for faces of concrete foundations and foundations beams (vertical or battering), as per HSR 9.13 (C.P.@ 400%) | BI01010001010000000000000515BI0100001118 | 615.54 | Sqm |
| 8 | 8 | Cement concrete 1 : 8 : 16 with brick ballast 40 mm Nominal size in foundation and plinth. (HSR 10.26) CP 450% | BI01010001010000000000000515BI0100001119 | 4.5 | Cum |
| 9 | 9 | Cement concrete 1: 4 : 8 with stone agg. 40 mm nominal size in foundation and plinth.(HSR 10.28) (CP 450%) | BI01010001010000000000000515BI0100001120 | 143.09 | Cum |
| 10 | 10 | Cement concrete 1 : 6 : 12 with stone aggregate 40 mm Nominal size in foundation and plinth., as per HSR 10.32(C.P.@ 450%) | BI01010001010000000000000515BI0100001121 | 7.32 | Cum |
| 11 | 11 | Cement concrete 1 : 4 : 8 with stone aggregate 40 mm Nominal size in foundation and plinth., as per HSR10.39 (C.P.@450 %) | BI01010001010000000000000515BI0100001122 | 568.77 | Cum |
| 12 | 12 | Cement concrete 1: 1.5 : 3 with stone aggregate 20 mm nominal size in foundation and plinth.(HSR 10.42) (CP 450%) | BI01010001010000000000000515BI0100001123 | 16.91 | Cum |
| 13 | 13 | Cement concrete 1 : 8 : 16 with brick ballast 40 mm nominal size in first storey upto 4 metres above plinth level. (HSR 10.44) CP 450% 4th Storey | BI01010001010000000000000515BI0100001124 | 29.77 | Cum |
| 14 | 14 | 6th storey | BI01010001010000000000000515BI0100001125 | 29.81 | Cum |
| 15 | 15 | Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level.(HSR 10.59) CP 450% | BI01010001010000000000000515BI0100001126 | 2.9 | Cum |
| 16 | 16 | Cement concrete 1:1 ½:3 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level, as per HSR 10.60 (C.P.@450%) 2nd Storey | BI01010001010000000000000515BI0100001127 | 0.58 | Cum |
| 17 | 17 | 3rd Storey | BI01010001010000000000000515BI0100001128 | 29.18 | Cum |
| 18 | 18 | 4th storey | BI01010001010000000000000515BI0100001129 | 12.3 | Cum |
| 19 | 19 | 6th storey | BI01010001010000000000000515BI0100001130 | 4.18 | Cum |
| 20 | 20 | Cement concrete 1:1:1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work but excluding steel-reinforcement centring and shuttering in foundation and plinth. (HSR 10.79+10.95 a)CP.450% | BI01010001010000000000000515BI0100001131 | 149.41 | Cum |
| 21 | 21 | Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respects. (10.81+10.95)(C.P 450%) Ist storey | BI01010001010000000000000515BI0100001132 | 0.5 | Cum |
| 22 | 22 | 4th storey | BI01010001010000000000000515BI0100001133 | 0.08 | Cum |
| 23 | 23 | Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering , laid in position, complete in all respects.(HSR 10.82+10.95) (C.P 450%) Ist storey | BI01010001010000000000000515BI0100001134 | 65.16 | Cum |
| 24 | 24 | 2rd storey | BI01010001010000000000000515BI0100001135 | 13.09 | cum |
| 25 | 25 | 3rd Storey | BI01010001010000000000000515BI0100001136 | 0.77 | cum |
| 26 | 26 | 4th Storey | BI01010001010000000000000515BI0100001137 | 21.29 | Cum |
| 27 | 27 | 5th storey | BI01010001010000000000000515BI0100001138 | 23.93 | Cum |
| 28 | 28 | 6th storey | BI01010001010000000000000515BI0100001139 | 133.15 | Cum |
| 29 | 29 | Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects.(HSR10.86+10.95)(CP450%) Ist storey | BI01010001010000000000000515BI0100001140 | 64.46 | Cum |
| 30 | 30 | 2rd storey | BI01010001010000000000000515BI0100001141 | 27.03 | Cum |
| 31 | 31 | 3rd Storey | BI01010001010000000000000515BI0100001142 | 38.34 | Cum |
| 32 | 32 | 4th Storey | BI01010001010000000000000515BI0100001143 | 38.34 | Cum |
| 33 | 33 | 5th storey | BI01010001010000000000000515BI0100001144 | 42.97 | Cum |
| 34 | 34 | 6th storey | BI01010001010000000000000515BI0100001145 | 163.51 | Cum |
| 35 | 35 | Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls (10 cm to 20 cm thickness) straight and curved excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects.(HSR 10.87+10.95) CP 450% 4th storey | BI01010001010000000000000515BI0100001146 | 6.8 | Cum |
| 36 | 36 | 6th storey | BI01010001010000000000000515BI0100001147 | 1.92 | Cum |
| 37 | 37 | Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for circular or curved columns excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects.(HSR 10.88+10.95 a)CP450% Ist Storey | BI01010001010000000000000515BI0100001148 | 0.53 | cum |
| 38 | 38 | 2nd Storey | BI01010001010000000000000515BI0100001149 | 0.2 | cum |
| 39 | 39 | Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by Item Nos. 10.82, 10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects.(HSR 10.89+10.95(a))(CP 450%) 1st Storey | BI01010001010000000000000515BI0100001150 | 5.77 | Cum |
| 40 | 40 | Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement complete in all respect (HSR 10.90+10.95(a)) (CP 450%) | BI01010001010000000000000515BI0100001151 | 334.1 | Cum |
| 41 | 41 | Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in arches or curved roof (curvature in one direction) excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. (HSR 10.91+10.95a) CP. 450% 5th storey | BI01010001010000000000000515BI0100001152 | 3.88 | Cum |
| 42 | 42 | Cement conc. 1:1.5:3 with stone aggregate 20mm nominal size in pavements, roads, taxi-tracks and runways, laid to required slope and camber, i/c consolidation, finishing and tamping complete (HSR 10.132+10.95(a)) (CP 450%) | BI01010001010000000000000515BI0100001153 | 494.96 | Cum |
| 43 | 43 | Damp proof course 40 mm thick of cement concrete 1:1.5:3 using stone aggregate 20 mm nominal size with 2 coats of bitumen 20/30 penetration, at 1.65 kg per sqm laid hot and sanded., as per HSR 10.114 (C.P.@450 %) | BI01010001010000000000000515BI0100001154 | 27.13 | Sqm |
| 44 | 44 | First class brick work laid in cement sand mortar 1:6 in foundation and plinth., as per HSR 11.2 (C.P.@600 %) | BI01010001010000000000000515BI0100001155 | 182.65 | Cum |
| 45 | 45 | First class brick work laid in cement sand mortar 1:4 in foundation and plinth. (HSR 11.4) (CP 600%) | BI01010001010000000000000515BI0100001156 | 47.81 | Cum |
| 46 | 46 | First class brick work work laid in cement sand mortar 1:4 in foundation and plinth (HSR 11.9) CP 600% | BI01010001010000000000000515BI0100001157 | 1.08 | Cum |
| 47 | 47 | 11.43 cm thick brick wall laid in cement mortar 1:4 without reinforcement in foundation and plinth. (HSR 11.47) CP 600% | BI01010001010000000000000515BI0100001158 | 6.5 | sqm |
| 48 | 48 | Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plster 1:4 or pointing, as required. (HSR 11.77)600% | BI01010001010000000000000515BI0100001159 | 155.11 | Cum |
| 49 | 49 | Providing and laying autoclaved aerated (Cellular) Concrete light weight blocks ( As per IS :2185,Part 3 having density of 550 to 650 kg/sqm and compressive strength of 4.0 N/mm2 masonary in non load bearing walls using 100 mm thick AAC blocks complete in all respec (as per HSR item 11.104(ii )+11.41 CP 0%) with polymer modified adhesive of reputed make as approved by Engineer - in - Charge Ist Storey | BI01010001010000000000000515BI0100001160 | 129.08 | sqm |
| 50 | 50 | 2nd Storey | BI01010001010000000000000515BI0100001161 | 12.4 | sqm |
| 51 | 51 | 4th storey | BI01010001010000000000000515BI0100001162 | 48.76 | sqm |
| 52 | 52 | 5th storey | BI01010001010000000000000515BI0100001163 | 30.66 | sqm |
| 53 | 53 | Providing and laying autoclaved aerated (Cellular) Concrete light weight blocks ( As per IS :2185, Part 3 having density of 550 to 650 kg/sqm and compressive strength of 4.0 N/mm2 masonary in non load bearing walls using more than 100 mm thick AAC blocks complete in all respec (as per HSR item 11.105(ii )+11.41 CP 0%) with polymer modified adhesive of reputed make as approved by Engineer - in - Charge Ist Storey | BI01010001010000000000000515BI0100001164 | 195.9 | Cum |
| 54 | 54 | 2nd Storey | BI01010001010000000000000515BI0100001165 | 31.31 | Cum |
| 55 | 55 | 3rd Storey | BI01010001010000000000000515BI0100001166 | 31.16 | Cum |
| 56 | 56 | 4th storey | BI01010001010000000000000515BI0100001167 | 72.86 | Cum |
| 57 | 57 | 5th storey | BI01010001010000000000000515BI0100001168 | 54.15 | Cum |
| 58 | 58 | 6th storey | BI01010001010000000000000515BI0100001169 | 55.84 | Cum |
| 59 | 59 | Applying bitumen on roofs including heating and carriage to roof. (HSR 13.59) CP 240% | BI01010001010000000000000515BI0100001170 | 1.96 | qtls |
| 60 | 60 | Cement concrete 1:2:4 gola 10 cm x 10 cm quadrant along junction of roof with parapet wall finished smooth where specially specified. (HSR13.64)240% | BI01010001010000000000000515BI0100001171 | 771.87 | Rmt |
| 61 | 61 | Providing & fixing PVC Rain water pipe 6 kg pressure of ISI mark in cement mortar during masonry work. (HSR 13.89) (a) 20% b)150 mm dia PVC pipe 6 kg pressure | BI01010001010000000000000515BI0100001172 | 179.56 | Rmt |
| 62 | 62 | Providing and fixing PVC bend ISI mark, as per HSR 13.90a(C.P.@ 20%) b) 150mm dia PVC bend | BI01010001010000000000000515BI0100001173 | 42 | Each |
| 63 | 63 | Providing & fixing False Ceiling with 12mm thick Gympsum Board fixed on M.S Steel runners frame i/c cost of screws angles, cleats, rawel plugs, with taping, filling with Gypsum compound and applying priming coat. Etc. complete in all respects. (HSR 13.91) CP 10% | BI01010001010000000000000515BI0100001174 | 3.31 | Sqm |
| 64 | 64 | Providing and fixing pressed clay tile (Manglore tiles) of size 200mm x 125mm x 10mm on slopping roof top/ window projections with 12mm thick cement, coarse sand mortar 1:3 including cost of ridge wherever requiredas per approved design complete in all respect up to 4 storey or 15 Metre Height. (HSR 13.95) CP 0% | BI01010001010000000000000515BI0100001175 | 4.37 | Sqm |
| 65 | 65 | Terracing consisting of 19mm thick heat resistant tiles for roof insulation, 300mm x 300mm laid on 20mm thick 1:3 cement coarse sand mortar including grouting with neat white cement over average 75mm thick screed of neat white cement over average 75mm thick screed of 1:8:16 including two coats of bitumen laid hot at 1.65kg. per sqmt on top of RCC slab & cleaning of top surface. (HSR 13.97) CP 0% | BI01010001010000000000000515BI0100001176 | 1014.33 | Sqm |
| 66 | 66 | Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping as per HSR 14.4 (CP @ 400%) 1st storey | BI01010001010000000000000515BI0100001177 | 24.51 | Sqm |
| 67 | 67 | 2nd storey | BI01010001010000000000000515BI0100001178 | 144.33 | Sqm |
| 68 | 68 | 3rd storey | BI01010001010000000000000515BI0100001179 | 5.11 | Sqm |
| 69 | 69 | 4th storey | BI01010001010000000000000515BI0100001180 | 98.64 | Sqm |
| 70 | 70 | 5th storey | BI01010001010000000000000515BI0100001181 | 5.11 | Sqm |
| 71 | 71 | 6th storey | BI01010001010000000000000515BI0100001182 | 65.2 | Sqm |
| 72 | 72 | Precast colour chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings., as per HSR 14.45+note (C.P.@ 400%) In case colour chequered tiles in flooring are used increase the through rate of Item No. 14.45 by 10% | BI01010001010000000000000515BI0100001183 | 19.66 | Sqm |
| 73 | 73 | Kotah stone flooring 25mm thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone., as per HSR 14.62 (C.P.@250%) 1st storey | BI01010001010000000000000515BI0100001184 | 615.51 | Sqm |
| 74 | 74 | 2nd Storey | BI01010001010000000000000515BI0100001185 | 82.31 | Sqm |
| 75 | 75 | 4th Storey | BI01010001010000000000000515BI0100001186 | 221.74 | Sqm |
| 76 | 76 | Extra for nosing in treads of steps of Kotah Stone slab. (HSR 14.65) CP 250% Labour Rate | BI01010001010000000000000515BI0100001187 | 115.89 | Rmt |
| 77 | 77 | Kotah stone 20 mm thick in skirting risers of steps, dados, pillars and wall facing (lining) in any pattern laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc., as per HSR 14.66 (C.P.@ 250%) 1st storey | BI01010001010000000000000515BI0100001188 | 32.39 | Sqm |
| 78 | 78 | 4th storey | BI01010001010000000000000515BI0100001189 | 79.4 | Sqm |
| 79 | 79 | Providing and fixing P.V.C strips, 40 mm Wide in floors. (HSR 14.81) CP 400% | BI01010001010000000000000515BI0100001190 | 29.72 | Sqm |
| 80 | 80 | Providing and fixing 1st quality ceramic Anti Skid tiles of size 400x400 mm condirming to I.S 15622 (thickness to by specified by the manu-facturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete. (HSR 14.91)-15% | BI01010001010000000000000515BI0100001191 | 74.12 | Sqm |
| 81 | 81 | Providing & fixing Ist quality ceramic glazed wall tiles confirming to IS 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades, except burgundy, bottle green, black of any size as approved by Engineer incharge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete, as per HSR 14.92a (C.P.@ 0%) (a) Size 200x300 mm | BI01010001010000000000000515BI0100001192 | 120.63 | Sqm |
| 82 | 82 | (b) Size 300x450 mm | BI01010001010000000000000515BI0100001193 | 286.29 | Sqm |
| 83 | 83 | 12mm thick cement plaster 1:4 (HSR 15.5) (CP 500%) 1st storey. | BI01010001010000000000000515BI0100001194 | 400.72 | Sqm |
| 84 | 84 | 12 mm thick cement plaster 1:6, as per HSR 15.7 (C.P.@ 500%) 1st storey | BI01010001010000000000000515BI0100001195 | 1185.32 | Sqm |
| 85 | 85 | 2nd storey | BI01010001010000000000000515BI0100001196 | 511.57 | Sqm |
| 86 | 86 | 3rd storey | BI01010001010000000000000515BI0100001197 | 659.9 | Sqm |
| 87 | 87 | 4th storey | BI01010001010000000000000515BI0100001198 | 197.78 | Sqm |
| 88 | 88 | 15mm thick cement plaster 1:4 (HSR 15.10)(CP 500%) 1st storey | BI01010001010000000000000515BI0100001199 | 190.07 | Sqm |
| 89 | 89 | 20 mm thick cement plaster 1:6 in 2 coats work. (HSR 15.17) CP 500% | BI01010001010000000000000515BI0100001200 | 41.2 | Sqm |
| 90 | 90 | 10 mm thick cement plaster 1:4, as per HSR 15.52 (C.P.@500 %) underside of ceiling 1st storey | BI01010001010000000000000515BI0100001201 | 487.28 | Sqm |
| 91 | 91 | 2nd storey | BI01010001010000000000000515BI0100001202 | 363.53 | Sqm |
| 92 | 92 | 3rd storey | BI01010001010000000000000515BI0100001203 | 484.16 | Sqm |
| 93 | 93 | 4th storey | BI01010001010000000000000515BI0100001204 | 138.61 | Sqm |
| 94 | 94 | 15 mm thick cement plaster 1:4 on the rough side of single or half brick wall as per HSR 15.10 (CP@ 500%) 1st storey | BI01010001010000000000000515BI0100001205 | 1004.97 | Sqm |
| 95 | 95 | 2nd storey | BI01010001010000000000000515BI0100001206 | 751.92 | Sqm |
| 96 | 96 | 3rd storey | BI01010001010000000000000515BI0100001207 | 578 | Sqm |
| 97 | 97 | 4th storey | BI01010001010000000000000515BI0100001208 | 630.22 | Sqm |
| 98 | 98 | 12 mm thick raised or sunk cement mortar band/drip course in cement mortar 1:4. (HSR 15.78) CP 500% | BI01010001010000000000000515BI0100001209 | 2025.4 | per metr per cm width |
| 99 | 99 | Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete., as per HSR 16.1 (C.P.@230 %) | BI01010001010000000000000515BI0100001210 | 189.96 | Sqm |
| 100 | 100 | Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc., as per HSR 16.2 (C.P.@ 230%) | BI01010001010000000000000515BI0100001211 | 189.96 | Sqm |
| 101 | 101 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade., as per HSR 16.3 (C.P@ 230 %) | BI01010001010000000000000515BI0100001212 | 556.47 | Sqm |
| 102 | 102 | Applying priming coat with metal primer on New steel or iron work including preparation of surface., as per HSR 16.9 (C.P.@ 230%) | BI01010001010000000000000515BI0100001213 | 317.9 | Sqm |
| 103 | 103 | Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work., as per HSR 16.58 (C.P.@ 230%) | BI01010001010000000000000515BI0100001214 | 2739.98 | Sqm |
| 104 | 104 | Pdg. two coats of exterior acrylic emulsion paint, as per HSR 16.79b (C.P.@ 0%), (b) 1st quality | BI01010001010000000000000515BI0100001215 | 4145.71 | Sqm |
| 105 | 105 | Providing and applying two coats of white cement based puttyover plusted surface and grinding the surface smooth with sand paper to get an even and smooth finish including and carrigage of all material, labour charges, scaffolding, sundries etc complete in all respect (JK/Birla make )as per HSR 16.81 (C.P @ 230 %) | BI01010001010000000000000515BI0100001216 | 6885.69 | Sqm |
| 106 | 106 | Providing and fixing plywood, plain lining butt-jointed , including wooden plugs (Teak, placed at 45 cm to 60 cm centres, complete with necessary nails (Frame work shall be payable extra)-(HSR 17.47) CP 300% (h) 12 mm thick 3 ply commercial ply wood with teak faced on one side | BI01010001010000000000000515BI0100001217 | 68.98 | Sqm |
| 107 | 107 | Cost of aluminium fitting cokmplte for doors and windows, such as tower bolts, handles, etc., and screws for these fittings (excluding sliding bolt)-HSR 17.72 CP.300% for single lead shutter | BI01010001010000000000000515BI0100001218 | 244.44 | Mtr. |
| 108 | 108 | Providing and fixing six-levers brass 10 cm mortice latch, with one dead bolt and a pari of lever handles with necessary screws, etc., complete (Indian mad of reputed firm, such as Godrej or equivalent) (HSR 17.74) CP 300% | BI01010001010000000000000515BI0100001219 | 1 | Each |
| 109 | 109 | Supplying and fixing hydraulic door Closer, I.S.I mark, with necessary Screws, etc., complete as per HSR 17.82 (CP @ 300%) c) I.S.I designation no. III (size of door 851 mm to 1000 mm) | BI01010001010000000000000515BI0100001220 | 28 | Each |
| 110 | 110 | Factory manufacture solid flush door and Shutters, with block board core as per I.S. No. 1659-1969 bonded with water poof type phenol formal dehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in positon includeing iron hinges, screws, chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position), as per HSR 17.93a-note 17.18-(i) (C.P.@ 165%) (a) commercial veneering with vertical grains or corss bands and face veneer on both sides commercial facing with laminated core and lipped edges. (i) 35mm | BI01010001010000000000000515BI0100001221 | 79.15 | Sqm |
| 111 | 111 | Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extruded buildt up standard tubular sections/approciate Z sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with raw plugs and screw or with fixing cilps or with expansion hold fasteners including necessary filling up of gaps at junstions at top bottom asn sides with required neoperne felt etc. Aluminium sections shall be smooth rust free straighty mitered adn jointed mechaniucally snap beading for glazing panefing CP brass stainless steel sorwer all complete Fixed portion (Anodized aluminium transparent or dyed to required shade according to Is; 1868 minimum anodic coating of grade AC15) powder coating of 50 micron. (HSR 17.95 + note (i))(CP 15%) | BI01010001010000000000000515BI0100001222 | 528.87 | kg |
| 112 | 112 | Providing and fixing Aluminium work for doors,windods,ventilators and partitins with extruded built up standard tubular sections/appropiate Z sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with raw plugs and screws or withfixing clips or wiht expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sidea wiht required neopene felt etc aluminium sections shall be smooth ,rust free staright mitered and jointed mechanically wharever required including clean angle, Aluminium snap beading for glazing/paneling C.P brass/stainless steel screws,ect complete.Shutters of doors ,windows & ventilators including providing and fixing of hinges/pivote and making provision for fixing of fitting wherever required inculde the cost of PVC/neo[rene gasket required incuding Aluminium fitting as per HSR 17.96+ note(i) ( CP @ 15%) with powder coating | BI01010001010000000000000515BI0100001223 | 301.47 | Kg |
| 113 | 113 | Providing and fixing glazing in aluminimum doods. Windows ventilator shutter and partitions etc with pvc/neoprene gasket etc complete (cost of aluminium snap beading shall be paid in basic items) as per HSR 17.98 (CP@ 15%) (ii) With float glass panes of 5mm thickness | BI01010001010000000000000515BI0100001224 | 33.76 | Sqm |
| 114 | 114 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS: 6315 marked for doors including cost of cutting floors as required embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box. (HSR 17.99a) CP 5% (a) With Stainless Steel cover plate. | BI01010001010000000000000515BI0100001225 | 2 | Each |
| 115 | 115 | Structural steel work in angles, tees and flats rivetted including cutting fixing all gusset plates, bolts, nuts, rivets, etc. with hoisting and erecting in position:- HSR 18.3 CP.500% | BI01010001010000000000000515BI0100001226 | 47 | Qtl |
| 116 | 116 | Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position as per HSR 18.12 (CP @ 500%) | BI01010001010000000000000515BI0100001227 | 106.85 | Qtl |
| 117 | 117 | Fe 500 EQR steel bars for R.C.C. works, where not included in the complete rate of R.C.C including bending, binding and placing in positon complete., as per HSR 18.22 (C.P.@ 500%) | BI01010001010000000000000515BI0100001228 | 1760.39 | Qtl |
| 118 | 118 | Supplying and fixing glass panes including special metal sash putty of approved make as per HSR 18.30 (CP @ 500%) b) glass panes 4 mm thick, exceeding 40 sq dm areas. | BI01010001010000000000000515BI0100001229 | 0.87 | Sqm |
| 119 | 119 | Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified sections, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, or approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lugs complete:-, as per HSR 18.34b(C.P.@ 500%) b) Door and window frame of size 76 mm X 38 mm with 35 mm wide single rebate | BI01010001010000000000000515BI0100001230 | 309.26 | Rmt |
| 120 | 120 | a) door and window frame of size 89X50X40mm wide single rebate. | BI01010001010000000000000515BI0100001231 | 40 | Mtr |
| 121 | 121 | c) door and window frame of size 127 mm X 50 mm with 40 mm wide double rebate. | BI01010001010000000000000515BI0100001232 | 50 | Mtr |
| 122 | 122 | Preparation of sub grade, including trenching, rough dressing of spoil final dressing of earth,to given levels and camber, watering, rolling with road roller, and compacting the bed HSR 24.1 CP. 370% | BI01010001010000000000000515BI0100001233 | 922.79 | % Sqm |
| 123 | 123 | Total Civil (HSR) | BI01010001010000000000000515BI0100001234 | ||
| 124 | 124 | P.H. (HSR PART) | BI01010001010000000000000515BI0100001235 | ||
| 125 | 125 | Excavation for pipelines running under pressureIn trenches and pits, in open areas, where disposal,Of surplus earth is done alongwith the alignmentIncluding trimming & dressing sides, leveling of beds of trenches to Correct grade, cutting joint holes, cutting trees and bushes, etc.,Refilling consolidation and watering of refill in 15 cm layers and Restoration of unmetalled or unpaved surface to ITS ORIGINAL CONDITION, including the cost of dewatering of rain Water, diversion of traffic, night signals, fixing caution boards, watching, Fencing etc., and outside the town in ORDINARY SOIL:- as per HSR6.8 a (C.P.@ 370%) a)Without timbering and shorting upto 1.5 metres depth | BI01010001010000000000000515BI0100001236 | 16.51 | %cum |
| 126 | 126 | Excavation of trenches in streets, lanes or in Open areas for storm sewer, sewers running by Gravity nd manholes to full depths as shown In drawings including shoring timbering of Poling boards, frame System type, dressing to correct Sections and dimensions, according to templates and levels, Dewatering, provision for diversion of traffic, cutting trees and Bushes etc. Night signals, profiles, pegs, sight rails, oning rods,Crossing over trenches for access to the houses, watching fencing, Etc., fixing and maintenance of caution boards, refilling of trenches, Watering of refill, in 15 m layers, ramming and restoration of Unmetalled or unpaved surface to original condition and removal Of surplus soil from site of work, upto a lead of 1 Km in ordinary soil., as per HSR6.10a (C.P.@ 370%) a) for depths of excavation not exceeding 3 metres, below ground level | BI01010001010000000000000515BI0100001237 | 48.04 | %cum |
| 127 | 127 | Cement concrete 1; 2 ; 4 with stone aggregate 20 mm nominal size in foundation and plinth, as per HSR 10.41 (C.P. @ 450%) | BI01010001010000000000000515BI0100001238 | 16.67 | Cum |
| 128 | 128 | DRILLING AND TAPPING CAST IRON PIPE LINES OF ALL DIAMETERS AND SCREWING IN FERRULE AND CONNECTIONS:-HSR 28.22 CP. 300% | BI01010001010000000000000515BI0100001239 | 1 | Each |
| 129 | 129 | CUTTING HOLES UPTO 23 CM SQUARE THROUGH STONE MASONARY OR BRICK WORK IN CEMENT WALLS FOR PIPES AND MAKING GOOD INCLUDING REPOINTING REPLASTERING AND FINISHING according to existing finish where required., as per HSR 28.24 (C.P.@300 %) a) 11.43 cm thickness of the walls b) 22.86 cm thickness of the walls | BI01010001010000000000000515BI0100001240 | 51 | Each |
| 130 | 130 | BAILING OUT WATER FROM THE TRENCHES FOR MAKING NEW CONNECTIONS IN FULLY CHARGED PIPE-LINES including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. HSR 28.47 CP. 300% | BI01010001010000000000000515BI0100001241 | 1 | Each |
| 131 | 131 | P/F in brass / gunmetal ferrules by drillign and tapping cast iron / DI / GI pipe line of all diameter and making connections i/c carraige, loading, unloading etc. complete in all respect, to the satisfaction of Engineer -in charge (excavation will be paid separately), as per HSR 28.54 (C.P.@ 10%) 10mm i/d ferrule | BI01010001010000000000000515BI0100001242 | 1 | Each |
| 132 | 132 | CONSTRUCTING BRICK MASONRY INSPECTION CHAMBER SIZES AS GIVEN BELOW UPTO 0.60 METRE AVERAGE DEPTH in cement Mortar 1:5 LIME CONCRETE with 40 percent lime mortar 2:3 in foundation Cement mortar 1:2:4 BENCHING 12 mm THICK CEMENT PLASTER 1:2 with a floating coat of 1 mm thick of neat cement R.C.C 1:2:4 SLAB 100 mm THICK/CC/ TOPPING 50 mm THICK WITH 455 MM x 455 MM X 610MM INSIDE LIGHT DUTY C.I. INSPECTION CHAMBER COVER AND FRAME Weight as per I.SI. specification painted WITH 3 COATS OF black bitumastic superior paint complete as per standard design., as per HSR29.84 (C.P.@ 450%) a)Size 450 mm x 450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 40 kg with C.C. topping ) | BI01010001010000000000000515BI0100001243 | 20 | Each |
| 133 | 133 | b)Size 600 mm x 900 mm inside (with 600 mm x 900 mm cover and frame light duty single seal pattern I weighing 38 kg with C.C.topping ) | BI01010001010000000000000515BI0100001244 | 7 | Each |
| 134 | 134 | EXTRA FOR EVERY 0.30 METRE DEPTH OF INSPECTION CHAMBER as per HSR 29.85 (CP@450%) b) 450mm x 600 mm | BI01010001010000000000000515BI0100001245 | 20 | Each |
| 135 | 135 | Providing and Fixing SFRC manhole covers and frames marked with IS:12592 including setting the same to correct lines & levels in 1:2 cement sand mortar over manhole including carraige, loading, unloading, stacking, handling, rehandling etc. complete in all respect to the satisfaction of Engineer- in - charges, as per HSR 29.94 (C.P.@ 5%) Type : Extra heavy duty set (HD-20) 560mm clear opening | BI01010001010000000000000515BI0100001246 | 20 | Each |
| 136 | 136 | Providing salt glazed stone ware pipes grade 'A' in standard length of 600mm each pipe marked with IS:651 and their lowering, cutting, jointing and testing as described in HSR item no 29.38, 29.39, 29.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, rehandling etc. complete in all respect to the satisfaction to the Engineer-in-charge, 150mm dia, as per HSR 29.95 (C.P.@ 5%) 200 mm i/dia | BI01010001010000000000000515BI0100001247 | 87.93 | Rmt |
| 137 | 137 | P/F in position best Indian make flat black or angular lipped front Urinal 465mm high consisting of HSR 30.19 CP. 340% i) White | BI01010001010000000000000515BI0100001248 | 7 | Each |
| 138 | 138 | PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE A RANGE OF TWO URINALS FLAT BACK OR ANGULAR LIPPED FRONT 610 HIGH IN VITREOUS CHINA-WARE WITH 5 LITRES CAPACITY BEST INDIAN MAKE C.I. AUTOMATIC FLUSHING CISTERN WITH FITTINGS AND FLUSH PIPE ETC., COMPLETE AS FULLY DESCRIBED IN ITEM NO. 30.25 ABOVE. as per HSR 30.26 (CP @ 340%) Range of Two urinals (i) White | BI01010001010000000000000515BI0100001249 | 4 | Each |
| 139 | 139 | PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE A RANGE OF THREE URINALS LARGE FLAT BACK OR ANGULAR LIPPED FRONT IN 610 MM HIGH IN VITREOUS CHINA-WARE WITH 10 LITRES CAPACITY BEST INDIAN MAKE C.I. AUTOMATIC FLUSHING CISTERN WITH FITTINGS AND FLUSH PIPE ETC., COMPLETE AS FULLY DESCRIBED IN ITEM NO 30.25 ABOVE as per HSR 30.27 (CP @ 340%) Range of Three urinals (i) White | BI01010001010000000000000515BI0100001250 | 2 | Each |
| 140 | 140 | PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE A RANGE OF FOUR URINALS LARGE FLAT BACK OR ANGULAR LIPPED FRONT IN 610 MM HIGH IN VITREOUS CHINA-WARE WITH TWO NOS.5 LITRES CAPACITY BEST INDIAN MAKE C.I. AUTOMATIC FLUSHING CISTERN WITH FITTINGS AND FLUSH PIPE ETC., COMPLETE AS FULLY DESCRIBED IN ITEM NO 30.25 ABOVE. as per HSR 30.28 (CP @ 340%) Range of four urinals white | BI01010001010000000000000515BI0100001251 | 2 | Each |
| 141 | 141 | Providing and fixing 25 mm thick backs for the different type of urinals as per HSR 30.40 (CP @ 340%) B) VITREOUS CHINAWARE PARTITION PLATE I) SMALL SIZE 680 mm x 330 mm i) White | BI01010001010000000000000515BI0100001252 | 5 | Each |
| 142 | 142 | PROVIDING AND FIXING IN POSITION INDIAN MAKE (ORDINARY) LAVATORY SUITES Consisting of Lavatory in VITREOUS CHINAWARE size as given Below (to the approval of the Engineer-in-charge) including china plug for tap hole where necessary; R.S or C.I BRACKETS for building into wall including Painting; 32 mm C.P BRASS WASTER WITH C.P brass chain and rubber plug; 15 mm C.P BRASS SCREW DOWN PILLAR TAP WITH Jamnuts or couplings best design ( as approved by the Engineer- In-charge) ALL FITTINGS BEST INDIAN MAKE and; to the approval of the Engineer-in-charge, ALL brass work chromium plated and COMPLETE in all respects INCLUDING cutting and MAKING GOOD THE WALLS FLOORS AND PAINTING OF FITTINGS ETC. as per HSR 30.41 (iv) (C.P.@ 340%) iv)Size 550 mm x 400 mm with one no. tap | BI01010001010000000000000515BI0100001253 | 4 | Each |
| 143 | 143 | Providing and fixing in position best Indian make Pedestal fittings of vitreous chinaware complete (as required by the Engineer-in-charge) as per HSR 30.44 (CP @ 340%) i) White | BI01010001010000000000000515BI0100001254 | 4 | Each |
| 144 | 144 | PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE TOWEL RAILS FIXED in with rawlslugs embedded in walls with C.P brass screws. Complete in all respect INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC as per HSR 30.68 (CP @ 340%) a) 25 MM DIA C.P BRASS ADJUSTABLE ii) 600 mm long. | BI01010001010000000000000515BI0100001255 | 8 | Each |
| 145 | 145 | Providing and fixing in position best Indian make Soap dish fixed into wall with C.P brass screws and complete in all respects including cutting and making good the wells etcs., as per HSR 30.70a(i) (C.P.@ 340%) a) C.P BRASS ii)Soap dish small | BI01010001010000000000000515BI0100001256 | 11 | Each |
| 146 | 146 | PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE BEVELLED EDGE 5.5 MM THICK MIRROR Mounted on ASBESTOS sheet GROUND FIXED IN POSITION BY MEANS OF 4 NOS. CHORMIUM PLATED BRASS SCREWS AND WASHERS over rubber washers and rawl plug embedded in the wall or chromium plated brass clamps with C.P brass screws (as required by the Engineer-in-charge) COMPLETE INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC.(HSR 30.71 a)(CP340%) 550 mm x 400 mm | BI01010001010000000000000515BI0100001257 | 18 | Each |
| 147 | 147 | Providing and fixing in position 15 mm i/d C.P brass bib Cocks of best quality (as required by Engineer-in-charge), as per HSR 30.75a,c (C.P.@ 340%). c) Bib cock | BI01010001010000000000000515BI0100001258 | 10 | Each |
| 148 | 148 | Providing and fixing in position C.P brass stop cocks (as Approved by the Engineer-in-charge), as per HSR 30.76 (C.P.@ 340%) a) 15 MM STOP COCK(i) Stop cock male and female end | BI01010001010000000000000515BI0100001259 | 31 | Each |
| 149 | 149 | a(ii) Concealed stop cock with flange | BI01010001010000000000000515BI0100001260 | 45 | Each |
| 150 | 150 | PROVIDING AND FIXING LEAD INLET CONNECTION WITH BRASS UNION FOR FLUSHING AND WARNING PIPES COMPLETE IN ALL RESPECTS.c)15 mm alkahene pipe inlet connection , as per HSR 30.93 c (C.P.@ 300%) | BI01010001010000000000000515BI0100001261 | 28 | Each |
| 151 | 151 | CUTTING CHASE IN BRICK WALLS IN CEMENT OR IN FLOOR FOR EMBEDDING B5684G.I OR H.C.I PIPE LINES AND MAKING GOOD THE SAME TO ITS ORIGINAL CONDITION as per HSR 30.95 (CP @ 340%) C) Size 75 mm x 50 mm | BI01010001010000000000000515BI0100001262 | 89.63 | Rmt |
| 152 | 152 | PROVIDING AND FIXING IN POSITION AUTOMATIC BRASSBALL VALVES IN TANKS, as per HSR 30.110b (C.P.@ 340%) b) With Plastic ball (ii) 20mm dia | BI01010001010000000000000515BI0100001263 | 2 | Each |
| 153 | 153 | iv) 32mm dia | BI01010001010000000000000515BI0100001264 | 4 | Each |
| 154 | 154 | PROVIDING AND FIXING HDPE water storage tank of Sintex, Diplast, O.K., Supreme make with cover / lids marked with ISI 12701 on roof top of building i/c cost of hoisting and placing in position, making connections with inlet and outlet pipe, providing overflow and scour provision with suitable plug on scour pipe i/c cost of nipples, washers, flanges for connection in tank, complete in all respect., as per HSR 30.119 (C.P.@ 0%) 500 Ltr | BI01010001010000000000000515BI0100001265 | 2 | Each |
| 155 | 155 | 1000 Ltrs | BI01010001010000000000000515BI0100001266 | 3 | Each |
| 156 | 156 | 5000 Ltr. | BI01010001010000000000000515BI0100001267 | 1 | Each |
| 157 | 157 | Total P.H. (HSR) | BI01010001010000000000000515BI0100001268 | ||
| 158 | 158 | NS CIVIL | BI01010001010000000000000515BI0100001269 | ||
| 159 | 159 | Finishing cement concrete with Vaccum dewatering system surface viberator and fine trowel complete in all respect | BI01010001010000000000000515BI0100001270 | 3249.64 | Sqm |
| 160 | 160 | Cutting groove in C C Work in road and Parking of size 50x5 mm NS | BI01010001010000000000000515BI0100001271 | 1483.15 | Sqm |
| 161 | 161 | Extra on account of labour for plaster for cornice RCC/Brick work in facia/parapet of various building in any design/ any height. 6th storey | BI01010001010000000000000515BI0100001272 | 112.85 | Rmt |
| 162 | 162 | Making of corbelling of cement concrete 1:1.5:3 i/c shuttering | BI01010001010000000000000515BI0100001273 | 149.35 | Rmt |
| 163 | 163 | Extra for moulding and nosing for kota stone, granite stone and green marble i/c granite polishing | BI01010001010000000000000515BI0100001274 | 919.56 | Sqm |
| 164 | 164 | P/F kerb stone of M25 grade of size 300x300x150 mm complete in all respect | BI01010001010000000000000515BI0100001275 | 200 | Each |
| 165 | 165 | Extra for making hole in working slab for gas pipe etc i/c finishing complete | BI01010001010000000000000515BI0100001276 | 10 | Each |
| 166 | 166 | Applying exterior primer on exterior surface of building for painting. | BI01010001010000000000000515BI0100001277 | 3765.57 | Sqm |
| 167 | 167 | Earth filling with the earth brought from outside the campus irrespective of any lead, including laying in 15cm in layers, watering and consolidating complete in all respect and fully satisfaction of Engineer-in-charge. | BI01010001010000000000000515BI0100001278 | 1018.37 | Cum |
| 168 | 168 | Extra for granite polish on Kota stone flooring, complete in all respect | BI01010001010000000000000515BI0100001279 | 1084.93 | Sqm |
| 169 | 169 | Pdg./Fixing in position Aluminium fittings for doors and windows. Tower Bolt 6\" | BI01010001010000000000000515BI0100001280 | 86 | Each |
| 170 | 170 | Tower bolt 8\" | BI01010001010000000000000515BI0100001281 | 68 | Each |
| 171 | 171 | Tower bolt 18\" | BI01010001010000000000000515BI0100001282 | 36 | Each |
| 172 | 172 | Handle 6\" | BI01010001010000000000000515BI0100001283 | 96 | Each |
| 173 | 173 | Handle 4\" | BI01010001010000000000000515BI0100001284 | 30 | Each |
| 174 | 174 | Hasp & staples 150mm long | BI01010001010000000000000515BI0100001285 | 20 | Each |
| 175 | 175 | Folding Handle | BI01010001010000000000000515BI0100001286 | 20 | Each |
| 176 | 176 | I-Hook | BI01010001010000000000000515BI0100001287 | 10 | Each |
| 177 | 177 | Providing & fixing of red sand stone in all shades in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 complete in all respect as per approved NS | BI01010001010000000000000515BI0100001288 | 3.15 | Sqm |
| 178 | 178 | Providing & fixing mummty door consiting of mild steel angle iron frame 35 x 35 x 5 mm thick cross braces 20 x 5 mm @ 4 nos. & covered with MS sheet flat 16 gauge complete as per approved NS. | BI01010001010000000000000515BI0100001289 | 150 | Kg |
| 179 | 179 | Providing and fixing stainless steel wiremesh jali of 23 gauge clear apeture 1.4 mm in 304 grade in aluminium door& windows in aluminium section including PVC/ neoprone gasket & labour for fixing complete as per NS | BI01010001010000000000000515BI0100001290 | 8.09 | Sqm |
| 180 | 180 | Providing and fixing of PVC clamp as per approved make NS 100 mm | BI01010001010000000000000515BI0100001291 | 40 | Each |
| 181 | 181 | Providing & fixing of ms threaded rod 6 mm dia as per approved NS | BI01010001010000000000000515BI0100001292 | 20 | Rmt |
| 182 | 182 | Providing & fixing of 20 mm dia hanging rod as per approved NS | BI01010001010000000000000515BI0100001293 | 50 | Rmt |
| 183 | 183 | Supplying laying of selection no 1 grass in campus i/c cartage of grass and labour for dressing ,ploughing ,and levelling of ground complete in all respect | BI01010001010000000000000515BI0100001294 | 185.8 | Sqm |
| 184 | 184 | EXTRA FOR PROVIDING WATER PROOFING TO AVOID SEEPAGE IN CEMENT PLASTER. | BI01010001010000000000000515BI0100001295 | 30.15 | bags |
| 185 | 185 | Making and cutting hole 100mm dia in RCC through core cutting matching complete in all respect. | BI01010001010000000000000515BI0100001296 | 12 | Each |
| 186 | 186 | P/F hole sixe 125mm dia (150mm depth) for drain water pipe and SWR pipe by using diamond core cutter Hilti make complete in all respect. | BI01010001010000000000000515BI0100001297 | 17 | Each |
| 187 | 187 | P/F chicken mesh of 150mm wide at joint of RCC and brick wall to avoid cracks complete in all respect. | BI01010001010000000000000515BI0100001298 | 67.44 | Rmt |
| 188 | 188 | Making chases in brickwork for providing skirting flush with the plaster. | BI01010001010000000000000515BI0100001299 | 380.38 | Rmt |
| 189 | 189 | P/L of POP on one coat on vitrified tiles, granite ot maintain its actual appearance and colour complete in all respect. | BI01010001010000000000000515BI0100001300 | 484.37 | Sqm |
| 190 | 190 | P/F rustic tiles 395x395mm size over 20mm thick cement mortar 1:3 complete in all respect. (DNIT-NS) | BI01010001010000000000000515BI0100001301 | 116.58 | Sqm |
| 191 | 191 | (Curten item) P/F motorised stage curtain (Front, middle & rear) made of velvet cloth with wings, frills, light bars, cyclorma, peerforated screen, backdeop system with horzontal slidding arrangement with heavy duty winch machine to roll the steel rope 3mm thick on convey or track complete with runner master runner, pullies electric 1 HP (Crompton/kirlokar) Air Breaker contactors 2 nos. (L&T/siemes) 2 Nos. Micro Switches for auto stop, 3 nos. push buttons for forward, reverse and stop position and also hand orperated mechanism would be installed to operate the curtain in case of electricity would be installed carriage of materials in all leads and lifts complete in all respect as per direction of Engineer-in-charge. NS | BI01010001010000000000000515BI0100001302 | 1 | No. |
| 192 | 192 | P/F perforated metal false ceiling of Modified Polyester coated with 20 Micron Galvinised sheet including Glass wool GI Rod, Clamp, Runner and Hooks, Fasterners screws etc. complete in all respect as per direction of Engineer-in-charge. NS | BI01010001010000000000000515BI0100001303 | 806.26 | Sqm |
| 193 | 193 | P/F wall penelling or cladding of modified polyester coated with 20micron Galvnised sheet including glass wool GI, Rod, Clamp, Runner and hooks fasteners screws etc. complete in all respect. As per directions of Engineer-in-charge. NS | BI01010001010000000000000515BI0100001304 | 655.52 | Sqm |
| 194 | 194 | Precast chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings. NS | BI01010001010000000000000515BI0100001305 | 61.77 | Sqm |
| 195 | 195 | Providing and making nosing (moulding) granite polish of granite stone. NS | BI01010001010000000000000515BI0100001306 | 345.67 | Rmt |
| 196 | 196 | Providing and fixing structural glazing with 5mm super blue toughned super blue toughned glass fix on aluminium section (Excluding the cost of aluminium) NS | BI01010001010000000000000515BI0100001307 | 44.34 | Sqm |
| 197 | 197 | Providing MS frame for fixing SS jali in aluminium door and windows shutter including cost of river, welding etc. complete in all respect. NS | BI01010001010000000000000515BI0100001308 | 22 | Each |
| 198 | 198 | Finishing heat resistant tiles by grinding machanically or roof trrace and disposal of wastage. NS | BI01010001010000000000000515BI0100001309 | 1014.13 | Sqm |
| 199 | 199 | P/F wiremash under slanting paneling to hold the glass wool in hight upto 40ft. Including necessary scaffolding required. NS | BI01010001010000000000000515BI0100001310 | 342.78 | Sqm |
| 200 | 200 | P/F hilti fastner of size 20x150mm with drill at height 40ft including necessary scaffolding required. NS | BI01010001010000000000000515BI0100001311 | 432 | Each |
| 201 | 201 | P/F hilti fastner of size 10x100mm with drill at height 40ft including necessary scaffolding required. NS | BI01010001010000000000000515BI0100001312 | 186 | Each |
| 202 | 202 | Providing holes in MS flat to be fixed on stair case for fixing fastner in stair case complete in all respect. NS | BI01010001010000000000000515BI0100001313 | 937 | Each |
| 203 | 203 | P/F MS fastner 100mm long and 10mm thick to steel balusters complete in all respect. NS | BI01010001010000000000000515BI0100001314 | 953 | Each |
| 204 | 204 | Providing & fixing in position stainless steel staircase railing 3 ft height grade 304, heavy duty gauge 14 in staircase as per drawing & as per approved by Engineer-in- Charge Complete in all respect. NS | BI01010001010000000000000515BI0100001315 | 337.28 | Kg |
| 205 | 205 | P/L 15mm thick wooden flooring of Bamboo hard wood on stage as per approved architecturral drawing, complete in all respect to the entire satisfifaction of Engineer-in-charge. Ns | BI01010001010000000000000515BI0100001316 | 119.2 | Sqm |
| 206 | 206 | Providing and fixing Handle lock 8431 Victoria godrej complete in all respect. | BI01010001010000000000000515BI0100001317 | 10 | Each |
| 207 | 207 | Providing and fixing door closer 1938 Godrej ( Hydraulic door closer ) | BI01010001010000000000000515BI0100001318 | 10 | Each |
| 208 | 208 | Supplying and fixing toughened glass 12mm partition with door with fitting complete with handle rod 25mm dia wall N connector , hinges, making hole etc. complete. | BI01010001010000000000000515BI0100001319 | 5.52 | Sqm |
| 209 | 209 | P/F PVC sintex tanki nipples with rubber washer and checkout etc. complete. 20mm | BI01010001010000000000000515BI0100001320 | 8 | Each |
| 210 | 210 | Providing & fixing wooden flooring 8mm thick victor make with 1mm thick foam with complete in all respect. | BI01010001010000000000000515BI0100001321 | 13.37 | Sqm |
| 211 | 211 | Providing & fixing roller blind as per NS of approval make. | BI01010001010000000000000515BI0100001322 | 71.34 | Sqm |
| 212 | 212 | Providing & fixing in position stainless steel staircase railing 3 ft height grade 304, heavy duty gauge 14 in staircase as per drawing & as per approved by Engineer-in- Charge Complete in all respect. | BI01010001010000000000000515BI0100001323 | 15 | kg |
| 213 | 213 | Provision for fastener for fixing white marble/granite/Red stone | BI01010001010000000000000515BI0100001324 | 50 | Each |
| 214 | 214 | P/F wire mesh under slanting paneling to hold the glass wool in height up to 40 feet including necessary scalding required at site. | BI01010001010000000000000515BI0100001325 | 8.15 | Sqm |
| 215 | 215 | P/F Hilti fasterner of size 20x150mm with drill at height of 40 feet including necessary scalding required at site. | BI01010001010000000000000515BI0100001326 | 18 | Each |
| 216 | 216 | P/L POP over Polythene sheet for protection of floor tiles. | BI01010001010000000000000515BI0100001327 | 278.7 | Sqm |
| 217 | 217 | /F of CP Extension nipple 15mm dia. NS | BI01010001010000000000000515BI0100001328 | 30 | Each |
| 218 | 218 | Providing and fixing in position for EWC CP jet spray with braided hose & connection, complete. NS | BI01010001010000000000000515BI0100001329 | 10 | Each |
| 219 | 219 | Providing and fixing RCC Jali 50mm thick with complete in all respect. (NS) | BI01010001010000000000000515BI0100001330 | 13.93 | Sqm |
| 220 | 220 | P/F 90mm clamp Zinc coated for (75mm PVC) pipe i/c cost of 12mm screw etc. complete in all respect. NS | BI01010001010000000000000515BI0100001331 | 10 | Each |
| 221 | 221 | P/F 100mm clamp Zinc coated for (100mm PVC) pipe i/c cost of 12mm screw etc. complete in all respect. NS | BI01010001010000000000000515BI0100001332 | 10 | Each |
| 222 | 222 | Making & core cutter hole 125mm dia RCC through core cutting machinery etc. complete in all respect. NS | BI01010001010000000000000515BI0100001333 | 25 | Each |
| 223 | 223 | Making & core cutter hole 100mm dia RCC through core cutting machinery etc. complete in all respect. NS | BI01010001010000000000000515BI0100001334 | 12 | Each |
| 224 | 224 | Applying 12mm thick plaster of carbelling in cement plaster 1:4 complete in all respect. NS | BI01010001010000000000000515BI0100001335 | 300 | Mtr |
| 225 | 225 | P/F chicken mesh Jali (App. 2.0Kg per 200sft) with nail and washer on wall, columns and beams etc. before applying plaster to avoid cracks at junction and intermediate of wall complete in all respect. NS | BI01010001010000000000000515BI0100001336 | 50 | Sqm |
| 226 | 226 | P/F 60mmx10mm outer MS fastener in wall and ceiling with drill machine complete in all respect. NS | BI01010001010000000000000515BI0100001337 | 50 | Each |
| 227 | 227 | Applying wall putty on ceiling, walls (interior and exterior) on uneven surface as per site requirtement JK, Birla brand wall putty to give smooth surface complete in all respect. | BI01010001010000000000000515BI0100001338 | 6490.49 | Sqm |
| 228 | 228 | P/F aluminium I-Hook for glazed window, shutter complete in all respect. | BI01010001010000000000000515BI0100001339 | 46 | Each |
| 229 | 229 | P/F Powder coated aluminum coated folding handle of window complete in all respect. | BI01010001010000000000000515BI0100001340 | 22 | Each |
| 230 | 230 | P/F acoustic treatment and false ceiling including thermal insulation on ceiling and walls by using glass wool layer of 50mm thick with a density of 24kg/cum covered with tissue paper panelling with G.L frame work of 50mmx15mm, 22 gauge channel with bottom layer of 12mm thick perforated Gyp-board i.e fULTON, LOUVER TON AND PLAIN AS REQUIRED AT SITE OR DRAWING, FINISHING WITH EMULSION paint, necessary screw and arrangement of scaffolding etc for walls and roof at all levels/height complete in all respect. | BI01010001010000000000000515BI0100001341 | 3410.17 | SQM. |
| 231 | 231 | P/F acoustic treatment and false ceiling including thermal insulation on ceiling and walls by using glass wool layer of 50mm thick with a density of 24kg/cum covered with tissue paper panelling with G.L frame work of 50mmx15mm, 22 gauge channel with top layer of 19mm thick approved wood wool board fire retardant pasted with blazer fabric etc as per NS. | BI01010001010000000000000515BI0100001342 | 273.12 | SQM. |
| 232 | 232 | P/Planting different type of plants including digging planting watering manure fertilizing etc. complete in all respect. Bottle Brush (Height 12'.0\") | BI01010001010000000000000515BI0100001343 | 20 | Each |
| 233 | 233 | Flosrijni (Height 14'.0\") | BI01010001010000000000000515BI0100001344 | 5 | Each |
| 234 | 234 | Dalmoth (Height 10'.0\") | BI01010001010000000000000515BI0100001345 | 10 | Each |
| 235 | 235 | Champa ( Height 3'.0\") | BI01010001010000000000000515BI0100001346 | 10 | Each |
| 236 | 236 | Tikoma (Height 6'.0:) | BI01010001010000000000000515BI0100001347 | 5 | Each |
| 237 | 237 | Chandni Double (Height 4'.0\") | BI01010001010000000000000515BI0100001348 | 20 | Each |
| 238 | 238 | Black Ficus (Height 3'.0\") | BI01010001010000000000000515BI0100001349 | 10 | Each |
| 239 | 239 | Panda (Height 2'.0\") | BI01010001010000000000000515BI0100001350 | 50 | Each |
| 240 | 240 | Cycus | BI01010001010000000000000515BI0100001351 | 5 | Each |
| 241 | 241 | Barleria | BI01010001010000000000000515BI0100001352 | 5 | Each |
| 242 | 242 | Golden Chandni (Height 3'.0\") | BI01010001010000000000000515BI0100001353 | 10 | Each |
| 243 | 243 | Bottle Palm (Height 13'.0\") | BI01010001010000000000000515BI0100001354 | 5 | Each |
| 244 | 244 | TOTAL NS (CIVIL ) | BI01010001010000000000000515BI0100001355 | ||
| 245 | 245 | PUBLIC HEALTH(NS) | BI01010001010000000000000515BI0100001356 | ||
| 246 | 246 | Providing and fixing in position M.S HOOKS for GI Pipe line complete. | BI01010001010000000000000515BI0100001357 | 200 | Each |
| 247 | 247 | Providing & fixing in position wall hung water closet, White colour, “Sahara range” (Parryware) walvit pan complete with all respect i.e. seat cover, jet spray, Tee size 110 x 110 x 110mm, Rubber ring, Push cock, as per fully satisfaction of Engineer-in-charge. | BI01010001010000000000000515BI0100001358 | 4 | Each |
| 248 | 248 | P/F SWR, PVC specials B class for santory works complete in all respect. 15mm | BI01010001010000000000000515BI0100001359 | 9 | Each |
| 249 | 249 | 20mm | BI01010001010000000000000515BI0100001360 | 8 | Each |
| 250 | 250 | Providing and fixing in position openable CP S.S jali of Heavy quality, 100mm dia of standard make approved by engineer in-charge complete in all respect. | BI01010001010000000000000515BI0100001361 | 33 | Each |
| 251 | 251 | Providing and fixing CP Brass extension Nipple, complete in all respect a) 15mm x 25mm | BI01010001010000000000000515BI0100001362 | 18.53 | Each |
| 252 | 252 | b) 15mm x40 mm | BI01010001010000000000000515BI0100001363 | 41 | Each |
| 253 | 253 | Providing & Fixing S.S SINK 1mm thick, 304 grade, Bowl size 510x1040x200mm, overall size 685mmx510mm. Model - SBF 08 Glossy, complete | BI01010001010000000000000515BI0100001364 | 2 | Each |
| 254 | 254 | Pdg. & fixing SWR UPVC pipe classic type ‘B’ and specials ISI marked (Kissan, Prince, Finolex make) including fitting joint solvent mixture complete in all respect- Pipe 90mm dia outer | BI01010001010000000000000515BI0100001365 | ||
| 255 | 255 | a) 110mm dia | BI01010001010000000000000515BI0100001366 | 188.27 | Rmt |
| 256 | 256 | b) 90 mm dia | BI01010001010000000000000515BI0100001367 | 125.32 | Rmt |
| 257 | 257 | Special for 110mm dia pipe Cowel | BI01010001010000000000000515BI0100001368 | 5 | Each |
| 258 | 258 | PVC Clamp | BI01010001010000000000000515BI0100001369 | 40 | Each |
| 259 | 259 | Plain Bend | BI01010001010000000000000515BI0100001370 | 48 | Each |
| 260 | 260 | Door tee | BI01010001010000000000000515BI0100001371 | 10 | Each |
| 261 | 261 | Plain Tee | BI01010001010000000000000515BI0100001372 | 21 | Each |
| 262 | 262 | Special for 90 mm dia pipe Cowel | BI01010001010000000000000515BI0100001373 | 7 | Each |
| 263 | 263 | Clamp | BI01010001010000000000000515BI0100001374 | 176 | Each |
| 264 | 264 | Bend | BI01010001010000000000000515BI0100001375 | 36 | Each |
| 265 | 265 | Plain tee | BI01010001010000000000000515BI0100001376 | 6 | Each |
| 266 | 266 | Door Tee | BI01010001010000000000000515BI0100001377 | 26 | Each |
| 267 | 267 | Floor trap | BI01010001010000000000000515BI0100001378 | 28 | Each |
| 268 | 268 | Pdg.and fixing in position 6mm thick looking mirror bevelled on sides fixing in position with necessary C.P. screws and washer complete. | BI01010001010000000000000515BI0100001379 | 9.29 | Sqm |
| 269 | 269 | P/F overhead shower of jquare (250x250mm) make model no. OHS 1829 complete in all respect. | BI01010001010000000000000515BI0100001380 | 4 | Each |
| 270 | 270 | Providing and fixing C.P brass bib cock Jaquat make OPL- 15037 | BI01010001010000000000000515BI0100001381 | 10 | Each |
| 271 | 271 | Providing and fixing C.P brass bib cock wall flange Jaquar make ORM-10037 | BI01010001010000000000000515BI0100001382 | 4 | Each |
| 272 | 272 | Providing and fixing in position CP brass angular stop cock with wall flange make jaqure , cat No. 29053 of fusion range complete in all respect . | BI01010001010000000000000515BI0100001383 | 10 | Each |
| 273 | 273 | Providing and fixing towel rail jaquare make complete AKB 35711. | BI01010001010000000000000515BI0100001384 | 10 | Each |
| 274 | 274 | Providing and fixing CP brass health Feccet of Jaquar make cat 573 complete in all respect. | BI01010001010000000000000515BI0100001385 | 4 | Each |
| 275 | 275 | Providing and fixing shop dish jaqure make cat No. 1177 N complete in all respect. | BI01010001010000000000000515BI0100001386 | 2 | Each |
| 276 | 276 | Providing and fixing toilet paper holder recessed type (cat No. 1551 ) Hotelier series jaqure make. | BI01010001010000000000000515BI0100001387 | 4 | Each |
| 277 | 277 | P/F diverter of jaquar make cat No. 29193 complete in all respect. | BI01010001010000000000000515BI0100001388 | 2 | Each |
| 278 | 278 | P/F G.I hook complete in all respect as per NS. | BI01010001010000000000000515BI0100001389 | 62 | Each |
| 279 | 279 | P/F in position of Ball valve gate valve viking make complete in all respect. | BI01010001010000000000000515BI0100001390 | 1 | Each |
| 280 | 280 | P/F G.I Ball valve 32mm dia complete in all respect. | BI01010001010000000000000515BI0100001391 | 23 | Each |
| 281 | 281 | P/F OVAL type wash basin chinaware of parryware, cera with CP pillar cock and CP waste of ESS-ESS brand complete in all respect. | BI01010001010000000000000515BI0100001392 | 11 | Each |
| 282 | 282 | P/F self cleaning jet spray in EWC complete in all respect. | BI01010001010000000000000515BI0100001393 | 10 | Nos. |
| 283 | 283 | P/F CP flange required die complete in all respect. | BI01010001010000000000000515BI0100001394 | 41 | Nos. |
| 284 | 284 | P/F electric water pup with 2 HP capacity etc as per NS. | BI01010001010000000000000515BI0100001395 | 1 | Nos. |
| 285 | 285 | P/F 1HP Motor complete in all respect. | BI01010001010000000000000515BI0100001396 | 1 | Nos. |
| 286 | 286 | P/F in position GI Hooks for GI pipes complete. | BI01010001010000000000000515BI0100001397 | 80 | Each |
| 287 | 287 | P&f SS letter/words of size 15'' ht.3'' wide .2'' deep on 3mm thick ACP sheet with MS frame complete. | BI01010001010000000000000515BI0100001398 | 9.75 | Each |
| 288 | 288 | Providing and fixing in position make best Indian counter wash basin its complete in all respect. (NS) | BI01010001010000000000000515BI0100001399 | 2 | Each |
| 289 | 289 | P/F ACP sheet with 5mm thick on expansion joint complete in all respect. | BI01010001010000000000000515BI0100001400 | 9.75 | Sqm |
| 290 | 290 | Tubewell Supplying and packing graded gravel of size as per relevant ISI 4097- 1988 as amended up to date as per specification. The gravel should be free of durt or vegitabe matter. Complete all as per specified and directed by engineer - in - charge. | BI01010001010000000000000515BI0100001401 | 10.31 | Cum |
| 291 | 291 | Supply and erection 150mm dia PVC pipe (plain) of approved make (CM)/ Finolex,. Prince, supreme, Astral, Jindal | BI01010001010000000000000515BI0100001402 | 250 | Mtr |
| 292 | 292 | Supply erection and testing of electric controal panel board for tube well consisting of M.S plote made of angle frame containg 1 No. fully automate air brake starter suitable for 7.5 HP morter & L&T make. | BI01010001010000000000000515BI0100001403 | 2 | Each |
| 293 | 293 | Supply of submerible cable of 4 sqmm of finolex make. Three phase | BI01010001010000000000000515BI0100001404 | 250 | Mtr |
| 294 | 294 | Supppling GI class b marked with IS:1239 IN 3.05M length, their threatding and welding with flanges (Heavy duty) on both sides, jointing with nuts and bolts marked with IS 1363, rubber gaskets, marked with IS 638 Jointing with pumpling machinery and loweing into tubewells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in-charge as per HSR 25.52 50 mm /d \n | BI01010001010000000000000515BI0100001405 | 50 | 3.05 Each |
| 295 | 295 | Drilling of 300 mm dia bore by hydraulic rotary drilling (reverse circulation method) according to ISI specification No.2800-1991 (Part-I) as amended upto date and modified to extent of the specification attached with this schedule of items of work in all kinds of soils and boulders upto 125mm dia except rocky strata including the cost of all consumable stores, fuel, oil, soil stabilizing material and transportation of rig and other accessories to the site proposed bore and back (including cost of lowering of all sizes of casing pipe while boring and extracting the same against earth frictions etc.) compete to the satisfaction of the Engineer-in-Charge. | BI01010001010000000000000515BI0100001406 | 250 | Mtr |
| 296 | 296 | Providing and Fixing 7.50 B.H.P submercible pump (KSB make) 200 LPM , Head 90 mtr and complete in all respect to the entire satisifaction. | BI01010001010000000000000515BI0100001407 | 1 | Each |
| 297 | 297 | Development of tubewell as per the method described in IS 11189-1985 suitable to the site condition and confirming to the requirement of clause 9.3 | BI01010001010000000000000515BI0100001408 | 35 | Hours |
| 298 | 298 | TOTAL PH (NS) | BI01010001010000000000000515BI0100001409 | ||
| 299 | 299 | DSR itmes. | BI01010001010000000000000515BI0100001410 | ||
| 300 | 300 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. DSR-2016 (8.13) 8.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. | BI01010001010000000000000515BI0100001411 | 448.81 | Sqm |
| 301 | 301 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : DSR-2016 (9.96) 9.96.1 300x16 mm | BI01010001010000000000000515BI0100001412 | 20 | Each |
| 302 | 302 | 9.96.2 250x16 mm | BI01010001010000000000000515BI0100001413 | 36 | Each |
| 303 | 303 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) DSR 2016/18.17.1A | BI01010001010000000000000515BI0100001414 | 10 | Each |
| 304 | 304 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : DSR-2016 (9.97) 9.97.3 200x10 mm | BI01010001010000000000000515BI0100001415 | 10 | Each |
| 305 | 305 | 9.97.4 150x10 mm | BI01010001010000000000000515BI0100001416 | 15 | Each |
| 306 | 306 | 9.97.5 100x10 mm | BI01010001010000000000000515BI0100001417 | 20 | Each |
| 307 | 307 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : DSR-2016 (9.100) 9.100.1 125 mm | BI01010001010000000000000515BI0100001418 | 10 | Each |
| 308 | 308 | 9.100.2 100 mm | BI01010001010000000000000515BI0100001419 | 20 | Each |
| 309 | 309 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessary screws etc. complete. DSR 2016 (9.101) 9.101.2 Twin rubber stopper | BI01010001010000000000000515BI0100001420 | 44 | Each |
| 310 | 310 | Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete. DSR-2016 (9.114) 9.114.1 Triple strip vertical type | BI01010001010000000000000515BI0100001421 | 12 | Each |
| 311 | 311 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : DSR-2016 (11.23) DSR-2016 (11.23.5) Udaipur green marble | BI01010001010000000000000515BI0100001422 | 151.52 | Sqm |
| 312 | 312 | Extra for pre finished nosing to treads of steps of marble stone. DSR-2016 (11.24) | BI01010001010000000000000515BI0100001423 | 20 | Mtr |
| 313 | 313 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. DSR-2016 (11.31) | BI01010001010000000000000515BI0100001424 | 25 | Mtr |
| 314 | 314 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:\n(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.\n(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding\noff junction of vertical and horizontal surface.\n(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.\n(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). DSR-2016 (22.3) | BI01010001010000000000000515BI0100001425 | 83.61 | Sqm |
| 315 | 315 | Supply & fixing of PVC waste pipe 32mm internal dia DSR/2016 17.28. | BI01010001010000000000000515BI0100001426 | 18 | Each |
| 316 | 316 | Total DSR-2016 (civil) | BI01010001010000000000000515BI0100001427 | ||
| 317 | 317 | DSR-2016 (P.H.) | BI01010001010000000000000515BI0100001428 | ||
| 318 | 318 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: DSR-2016 (17.1) 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | BI01010001010000000000000515BI0100001429 | 4 | Each |
| 319 | 319 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. DSR-2016 (17.78) | BI01010001010000000000000515BI0100001430 | 4 | Each |
| 320 | 320 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.\n Internal work - Exposed on wall DSR-2016 (18.10) 18.10.1 15 mm dia nominal bore | BI01010001010000000000000515BI0100001431 | 82.27 | Mtr |
| 321 | 321 | 18.10.2 20 mm dia nominal bore | BI01010001010000000000000515BI0100001432 | 92.28 | Mtr |
| 322 | 322 | 18.10.4 32 mm dia nominal bore | BI01010001010000000000000515BI0100001433 | 464.08 | metre |
| 323 | 323 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : DSR-2016 (18.11) 18.11.1 15 mm dia nominal bore | BI01010001010000000000000515BI0100001434 | 50 | Mtr |
| 324 | 324 | 18.11.2 20 mm dia nominal bore | BI01010001010000000000000515BI0100001435 | 30 | Mtr |
| 325 | 325 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.\nExternal work DSR-2016 (18.12) 18.12.5 40 mm dia nominal bore | BI01010001010000000000000515BI0100001436 | 50 | Mtr |
| 326 | 326 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : DSR-2016 (18.17) 18.17.1A 20 mm nominal bore | BI01010001010000000000000515BI0100001437 | 8 | Each |
| 327 | 327 | 18.17.1 25 mm nominal bore\nCode | BI01010001010000000000000515BI0100001438 | 8 | Each |
| 328 | 328 | 18.17.3 40 mm nominal bore | BI01010001010000000000000515BI0100001439 | 8 | Each |
| 329 | 329 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : DSR-2016 (18.46) 18.46.1 15 mm nominal bore | BI01010001010000000000000515BI0100001440 | 10 | Each |
| 330 | 330 | 18.46.2 20 mm nominal bore | BI01010001010000000000000515BI0100001441 | 18 | Each |
| 331 | 331 | 18.46.3 25 mm nominal bore | BI01010001010000000000000515BI0100001442 | 8 | Each |
| 332 | 332 | 18.46.4 32 mm nominal bore | BI01010001010000000000000515BI0100001443 | 21 | Each |
| 333 | 333 | 18.46.5 40 mm nominal bore | BI01010001010000000000000515BI0100001444 | 20 | Each |
| 334 | 334 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : DSR 13.43 13.43.1 Water thinnable cement primer | BI01010001010000000000000515BI0100001445 | 4145.71 | Sqm. |
| 335 | 335 | Total DSR itmes. | BI01010001010000000000000515BI0100001446 | ||
| 336 | 336 | Chairs | BI01010001010000000000000515BI0100001447 | ||
| 337 | 337 | Providing and installation of Deluxe Auditorium Chairs with specification as given below:- | BI01010001010000000000000515BI0100001448 | ||
| 338 | 338 | 1) Seat/Back Assembly: The back and base frame shall be made up polyurethene foam moulded with cold rolled pipes with spring in between frames / M.S. Tubular frame having frame thickness of 2 mm. The back shall be of flexi type. The size of seat and back are as under:- (i) Back size - 60 cm (H) x 47 cm (W) (±3 mm) (ii) Seat size - 47 cm (D) x 47 cm (W) (± 3 mm) | BI01010001010000000000000515BI0100001449 | 588 | Each |
| 339 | 339 | 2) Polyurethane Foam:- The Polyrethane foam to be used for seat and back shall be invariably Fire Retardant in nature in confirming with the Class FMVS 302 specification, having a density = 50 (±5) kg/cum and the hardness should be of 20 ±2kgf on Hampden machine at | BI01010001010000000000000515BI0100001450 | ||
| 340 | 340 | 3) Armrests:-a) Without Cupholder - The one piece armrests are made of an integral scheme polyurethene foam with 120 off shore hardness and reinforced with MS frame insert. The individual armrest between the chair with a minimum width of 70 mm. b) With cupholder- The first rows chair armrest will be provided with cup holder as per drawing or as approved by Engineer-in-charge. | BI01010001010000000000000515BI0100001451 | ||
| 341 | 341 | 4) Back Tilt Mechanism - It shall be push back mechanism with coil spring steel system as per IS 4454-1981, Grade 2, slide of 4\". The mechanism should be noise free and tested for 50,000 cycles more. | BI01010001010000000000000515BI0100001452 | ||
| 342 | 342 | 5) Understructure Assembly: It shall be made up of MS black powder coated channel (2 mm thick) supported by strips (minimum 50mm x 5 mm). The foot pipes shall be of twin legged supporting with suitable base supporting. Fixing of chairs- All chairs are to fixed / anchored with 10 x 125 mm fasteners with washer and nuts of Hilti / Fisher make Zinc coated on existing floor as approved by Engineer-in-charge. | BI01010001010000000000000515BI0100001453 | ||
| 343 | 343 | 6) Back Base Covers- The chair back and base cover by the polypropelene copolymer (PPCP) covers with minimum thickness of 5mm from all sides. The base cover must have holes to assist sound absorption. | BI01010001010000000000000515BI0100001454 | ||
| 344 | 344 | 7) Cloth:- Fabric shall be of fire retardant of branded make as approved by Engineer-in-charge and may be tested for 50,000 abrasive cycles and having costing not less than Rs. 225 per meter. | BI01010001010000000000000515BI0100001455 | ||
| 345 | 345 | 8) Powder coating - All exposed metal structure to be well phosphated and powder coated with epoxy of minimum thickness of 80 microns. | BI01010001010000000000000515BI0100001456 | ||
| 346 | 346 | a) The warranty period for replacement and maintenance of Auditorium Chairs shall be three years from date of handing over with the complete satisfaction of Engineer-in-charge. b) Regarding warranty and AMC of the product: The security 5% of gross work done will be deducted from the running bill and the same will be released after the successful completion of warranty period. However, the agency may submit te Bank Guarantee in lieu of security | BI01010001010000000000000515BI0100001457 | ||
| 347 | 347 | Note* (i) The colour of the chair should be of Ruby red/ Azure blue or as per approved by the Engineer-in-charge. First two rows chair will be of one colour and the remaining chairs will be of other colour. | BI01010001010000000000000515BI0100001458 | ||
| 348 | 348 | Chairs Total | BI01010001010000000000000515BI0100001459 | ||
| 349 | 349 | NS Fire Fighting | BI01010001010000000000000515BI0100001460 | ||
| 350 | 350 | Providing pipe protection for underground pipes from corrosion painting pipe with primer and covered with anticorrosive tape as per specification.NS | BI01010001010000000000000515BI0100001461 | ||
| 351 | 351 | (b)Digging and back filling of trench for pipe lines. | BI01010001010000000000000515BI0100001462 | ||
| 352 | 352 | 150mm | BI01010001010000000000000515BI0100001463 | 329.68 | Rmt. |
| 353 | 353 | a) 100mm | BI01010001010000000000000515BI0100001464 | 461.84 | Rmt. |
| 354 | 354 | Providing and fixing of heavy duty'C' Class MS/ iron pipe ISI marked 1239 Part-I with special accessories such as elbow,welding joints,rubber inseration nut and bolts including fixing the pipe on wall ceilling with suitable iron, claimps bracket painting etc. complete as required.(JINDAL HISSAR.NS (C) 150mm | BI01010001010000000000000515BI0100001465 | 310.84 | Rmt. |
| 355 | 355 | (d) 100 mm dia | BI01010001010000000000000515BI0100001466 | 12.42 | Rmt. |
| 356 | 356 | providing and fixing of gate valve with complete fittings.(Sant,DRP,Arrow,B.S.).NS | BI01010001010000000000000515BI0100001467 | 2 | Each |
| 357 | 357 | providing and fixing cast iron butterfly valve complete with epoxy coated disc, carbon steel shaft and lever actuator tested and rubber gasket including flandes.( KIRLOSKAR, IVC, Zoloto, KORO, GANGA ETC.) NS (a) 100mm | BI01010001010000000000000515BI0100001468 | 5 | Each |
| 358 | 358 | (e)150mm | BI01010001010000000000000515BI0100001469 | 7 | Each |
| 359 | 359 | Providing and fixing cast iron dual plate type horizontal/vertical non return valve complete with flanges.( KIRLOSLKAR, IVC,ZOLOto,HORO,GANGA ETC)NS (b)100mm | BI01010001010000000000000515BI0100001470 | 4 | EACH |
| 360 | 360 | (C) 150mm | BI01010001010000000000000515BI0100001471 | 1 | EACH |
| 361 | 361 | Providing & fixing pressure gauge with isolation cock suitable for a working pressure | BI01010001010000000000000515BI0100001472 | 6 | EACH |
| 362 | 362 | Providing fixing single/multi stage outlet pumping set with bronze impeller with C.I. Body connected by a flexible coupling to a totally enclosed fan cooled induction motor mounted on common structural base plate including foundation with all pump a accessories complete as per specifications Pump/motor to be suitable for 415 volts, 3 phase,50 cycles A/c supply (main pump motors to be provided with inbuilt heating arrangement)(Kirloskar) | BI01010001010000000000000515BI0100001473 | 1 | Nos. |
| 363 | 363 | Providing &fixing jockey pumps 180LPM80m head with TEFC motor complete with all accessories complete in alla respects.a capacity: 180 LPM | BI01010001010000000000000515BI0100001474 | 1 | Nos. |
| 364 | 364 | supplying, installing, testing and commissionong centrifugal horizontal pumping set with mechanical seal CI body means of a flexible love joy coupling with coupling gaurdsto a diesal engine mounted on a common structural base plate with anti-viberation pads complete with electrical panel, battery (including one spare battery), automatic starting arrangements,exhaust pipe of 6m lenght to discharge outside the building with muffler,200 litres capacity oil tank supports complete in all respects as per specifications.(KIRLOSKAR) | BI01010001010000000000000515BI0100001475 | 1 | Nos. |
| 365 | 365 | Providing & fixing pressure switches ( with wiring from control panel to pressure switch) | BI01010001010000000000000515BI0100001476 | 3 | Nos. |
| 366 | 366 | Providing and fixing of heavy duty'C' Class MS/ iron pipe ISI marked 1239 Part-I with special accessories such as elbow,welding joints,rubber inseration nut and bolts including fixing the pipe on wall ceilling with suitable iron, claimps bracket painting complete as required (JINDAL HISAR).80mm | BI01010001010000000000000515BI0100001477 | 64.92 | Rmt. |
| 367 | 367 | Providing and fixing of 63mm dia 15 Mtr. Long canvas hose pipe complete with gun metal Male& Female coupling.(MINIMAX,SAFEX,PGC,GETECH ETC.) NS | BI01010001010000000000000515BI0100001478 | 11 | Nos. |
| 368 | 368 | Providing and fixing of First Aid Hose Reel swinging type with 20mm dia Nozzle complete with drum and suitable bracket etc.(MINIMAX,SAFEX,PGC,GETECH ETC.) NS | BI01010001010000000000000515BI0100001479 | 3 | Nos. |
| 369 | 369 | Providing and fixing of 63mm dia instantaneous pattern short branch pipe of gun metal.(MINIMAX,SAFEX,PGC,GETECH ETC.)NS | BI01010001010000000000000515BI0100001480 | 11 | Nos. |
| 370 | 370 | Providing and fixing cast iron butterfly valve complete with epoxy coated disc, carbon steel shaft and lever actuator tested and rubber gasket including flanges.(KIRLOSKAR,IVC,ZOLOTO,KORO,GANGA ETC.) NS | BI01010001010000000000000515BI0100001481 | 11 | Nos. |
| 371 | 371 | Providing and fixing of weather proof standered Hose cabinet of suitable size made out of not less than 16SWG M.S sheet & Tabular pipe including necessary locking arrangement,painting as required. (a)External BoxX500mmX500mmX250mm | BI01010001010000000000000515BI0100001482 | 9 | Nos. |
| 372 | 372 | Providing and fixing of vertical type air vessel tank fabricated from 8mm thick m.s plate with dish ends 200mm dia and 1.5 mtrs.high for drop the water air pressure in the pipe line and including drain valve,air valve and pressure guage etc. | BI01010001010000000000000515BI0100001483 | 2 | Nos. |
| 373 | 373 | Providing and fixing of fire extinguisher of CO2 type of 4.5 kg. capacity complete with Horn and valve with initial charge as required. | BI01010001010000000000000515BI0100001484 | 16 | Nos. |
| 374 | 374 | Providing & fixing of fire Extinguisher ABC type 6 kg. capacity complete with Horn,Valve guage with initial charge etc. | BI01010001010000000000000515BI0100001485 | 16 | Nos. |
| 375 | 375 | Providing and fixing Electrical Panel of cubical type floor mounted powder coated for control of above pumps for fire fighting suitable switch gear, busbars,on off relays, starter, timers, indicating lamps, fuses instruments, automatic isolators, conntactors and auxillary switch including connection complete as required for 1 no. main pump with auto start switching facillity and manual on off 1 no. jockey pumps, auto start/ off and auto start for diesel engine,1 no.gterrace pump and one no. fill pump complete as required. the panel shall be made as per required. | BI01010001010000000000000515BI0100001486 | 1 | Nos. |
| 376 | 376 | Providing and fixing Power cable 1.1KV copper conductor including supplying, making and termination with brass, comptression glands, from electrical panel to motor earthing og machinery alongwith earth pits as per site requirement. | BI01010001010000000000000515BI0100001487 | 1 | Nos. |
| 377 | 377 | Providing and fixing single headed oblique landing valve with flanged confirming to IS 5290 complete in all respect. | BI01010001010000000000000515BI0100001488 | 11 | Nos. |
| 378 | 378 | Providing and fixing two way fire brigade connection with selector valve.MS cover box etc. complete in all respect. | BI01010001010000000000000515BI0100001489 | 2 | Nos. |
| 379 | 379 | Providing and fixing 200 mm dia heavy duty class-c M/S iron pipe with special accessories pipe such as elbow and special complete in all respect. | BI01010001010000000000000515BI0100001490 | 6.1 | Rmt |
| 380 | 380 | Providing and fixing of cast iron 'D' strainer including rubber gasket , flanges nut-bolt and washer complete as required. (250 mm dia) | BI01010001010000000000000515BI0100001491 | 2 | Nos. |
| 381 | 381 | Total F.F NS | BI01010001010000000000000515BI0100001492 | ||
| 382 | 382 | E. I HSR Part | BI01010001010000000000000515BI0100001493 | ||
| 383 | 383 | S/E of miniature circuit breaker/isolator 240/415 Volts in existing distribution board i/c making necessary connections.( 31.17 ) (CP 30%) | BI01010001010000000000000515BI0100001494 | ||
| 384 | 384 | A) MCB of 9KA breaking capacity. | BI01010001010000000000000515BI0100001495 | ||
| 385 | 385 | ii) SPMCB 6 Amp to 32 Amp | BI01010001010000000000000515BI0100001496 | 92 | Each |
| 386 | 386 | ii) SPNMCB 6 Amp to 32 Amp | BI01010001010000000000000515BI0100001497 | 15 | Each |
| 387 | 387 | iii) SPNMCB 40 Amp to 63 Amp | BI01010001010000000000000515BI0100001498 | 2 | Each |
| 388 | 388 | ii) TPNMCB 6 Amp to 32 Amp | BI01010001010000000000000515BI0100001499 | 2 | Each |
| 389 | 389 | iii)TPNMCB 40 to 63 Amp | BI01010001010000000000000515BI0100001500 | 13 | Each |
| 390 | 390 | S/E of Four Pole moulded case circuit breaker on wall or on existing pedestal including bonding to earth and necessary connections ( HSR - 31.12- C ) ( CP - 60% ) ii ) 100 to 220 amp., 415 V, 10 KA, TP | BI01010001010000000000000515BI0100001501 | 3 | Each |
| 391 | 391 | iv ) 300 to 400 amp., 415 V, 36 KA, TP | BI01010001010000000000000515BI0100001502 | 2 | Each |
| 392 | 392 | xxvi) S/E of hexagonal MS box 1.6mm thick, 8cm,7.5cm deep top covered with MS lid by means of screws i/c 10mm dia. 30cm long MS rod made into suitable suspension hook & with 3mm thick backlite sheet erected in RCC slab complete. (HSR 31.18) CP-200% | BI01010001010000000000000515BI0100001503 | 28 | Each |
| 393 | 393 | xx) Supply and erection of rectangular bulk head fitting of size 17 cm x 14 cm, aluminium casted with aluminium colour outside and white stove enamelled inside/complete with guard, glass etc. secured by brass screws suitable upto 100 Watts lamp with B.C. Lamp (HSR 31.18) CP-200% | BI01010001010000000000000515BI0100001504 | 4 | Each |
| 394 | 394 | ix) Bakilite angle/straight button holder large size. | BI01010001010000000000000515BI0100001505 | 21 | Each |
| 395 | 395 | PIPE LAYING:- (HSR 31.21 ) (CP 350%) S/E of pipe for wiring purpose i/c bends inspection boxes etc. where necessary and painting as required.(HSR No. 31.21) xiv) GI pipe 65mm dia flushed. | BI01010001010000000000000515BI0100001506 | 20 | Metrs |
| 396 | 396 | EARTHING:- (HSR 31.22) (CP 350%) iii) Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing enclosures accessories and providing enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. | BI01010001010000000000000515BI0100001507 | 2 | Each |
| 397 | 397 | (iii) Earthing with tinned Copper earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required | BI01010001010000000000000515BI0100001508 | 4 | Each |
| 398 | 398 | v) Extra for charcoal or coke and salt for GI plate or copper plate earth electrode. | BI01010001010000000000000515BI0100001509 | 6 | Each |
| 399 | 399 | xv) Pdg. and fixing 25 mm x 5 mm G.I strip on surface or in recess for connection etc. as required with all labour and material | BI01010001010000000000000515BI0100001510 | 70 | mtr |
| 400 | 400 | xiv) Pdg. and fixing 25 mm x 5 mm copper strip in 40mm dia G.I pipe on surface or in recess for connection etc. as required with all labour and material | BI01010001010000000000000515BI0100001511 | 30 | mtr |
| 401 | 401 | xiv) Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required with all labour and material | BI01010001010000000000000515BI0100001512 | 70 | mtr |
| 402 | 402 | Galvanised iron Lighting Arrestor(HSR 31.24) ( CP - 350% ) ii) Excavation earth pit 180 cm round at Top and 90 cm at bottom 4.5 metres deep and refilling the same in plains including supply of necessary charcoal/ coke and salt mixture. | BI01010001010000000000000515BI0100001513 | 4 | Each |
| 403 | 403 | iv) Supply and erection of 60 cm x 60 cm x 6 mm thick galvanised iron plate including necessary bolts and nuts to G.I. tape. | BI01010001010000000000000515BI0100001514 | 4 | Each |
| 404 | 404 | v) Providing standard watering tank including down pipe and C.I cover with locking arrangements etc. | BI01010001010000000000000515BI0100001515 | 4 | Each |
| 405 | 405 | vi) Supply and erection of 20 mm x 3 mm thick lighting conductor G.I. tape fixed with suitable G.I stapples of same size. | BI01010001010000000000000515BI0100001516 | 205 | mtr |
| 406 | 406 | vi) Supply and erection of 32 mm x 6mm thick lighting conductor G.I. tape fixed with suitable G.I stapples of same size. | BI01010001010000000000000515BI0100001517 | 220 | mtr |
| 407 | 407 | viii) Supply and erection of 25 mm dia metre 1.5 metre long lighting G.I. tube rod tapped into a point at the top with 16 cm x 16 cm x 3 mm thick G.I Base plate and necessary nuts and bolts with washer. | BI01010001010000000000000515BI0100001518 | 6 | Each |
| 408 | 408 | ix) Providing and fixing, testing joint made of 20 mm x 3 mm thick G.I. strips 125 mm long with 4 nos. G.I bolts and Nuts with washer complete | BI01010001010000000000000515BI0100001519 | 4 | Each |
| 409 | 409 | S/E of under ground cable loose in existing pipe or trenches including necessary connection, digging and refilling of trenches . (HSR 31.26) (CP 140%) xxvii) 70 sqmm 3.5 core cable (arm) | BI01010001010000000000000515BI0100001520 | 280 | Metrs |
| 410 | 410 | xxix) 95 Sq. mm 3.5 Core Cable . | BI01010001010000000000000515BI0100001521 | 250 | Metrs |
| 411 | 411 | Supply & Erection PVC unsheathed Copper conductor cable single core 1100 Volts grade in pipe of suitable size( excluding cost and erection of pipe) (HSR 31.40) (CP 10%) i) Size 1.5 Sqmm | BI01010001010000000000000515BI0100001522 | 7500 | Metrs |
| 412 | 412 | iii) Size 4.0 Sqmm | BI01010001010000000000000515BI0100001523 | 1800 | Metrs |
| 413 | 413 | v) Cable size 10 sqmm(1.35mm) | BI01010001010000000000000515BI0100001524 | 240 | Metrs |
| 414 | 414 | vi) Cable size 16 sqmm(7/1.70mm) | BI01010001010000000000000515BI0100001525 | 400 | Metrs |
| 415 | 415 | vii) Cable size 25 sqmm(7/2.14mm) | BI01010001010000000000000515BI0100001526 | 380 | Metrs |
| 416 | 416 | viii) Cable size 35 sqmm(7/2.52mm) | BI01010001010000000000000515BI0100001527 | 600 | Metrs |
| 417 | 417 | SHEET STEEL ENCLOSURE: Supply & erection of sheet steel enclosure Double door distribution boards suitable for MCBs etc. recessed in wall with rag bolts i/c bonding to earth& necessary connections. (HSR 31.41) (CP 10%) 4-way, TP & N (Horizontal) (8+12) | BI01010001010000000000000515BI0100001528 | 5 | Each |
| 418 | 418 | 8-way, TP & N (Horizontal) (8+24) | BI01010001010000000000000515BI0100001529 | 4 | Each |
| 419 | 419 | 12-way, TP & N (Vertical) (8+36) | BI01010001010000000000000515BI0100001530 | 4 | Each |
| 420 | 420 | P/F modular type accessories of approved make in existing box i/c fixing and making necessary connection, complete in all respect. (HSR 31.56) CP-0% i) 10 amp. 1 way switch | BI01010001010000000000000515BI0100001531 | 32 | Each |
| 421 | 421 | iv)10 amp. Socket | BI01010001010000000000000515BI0100001532 | 32 | Each |
| 422 | 422 | Fan regulator | BI01010001010000000000000515BI0100001533 | 28 | Each |
| 423 | 423 | ix) Blanking Plate | BI01010001010000000000000515BI0100001534 | 34 | Each |
| 424 | 424 | S/E of mark double walled corrugated(DWC)HDPE pipe laid 1 mtr. Below ground level i/c diging and refilling of earth i/c cost of suitable size socket/ cuppler for HDPE pipe i/c the cost of labour and material required to complete the job in all respect up to the entire satisfaction of EIC of the work.(HSR 31.67) CP 0% HDPE pipe 90/75mm outer dia/ inner dia. | BI01010001010000000000000515BI0100001535 | 159 | mtr |
| 425 | 425 | S/I/T/C of Four Pole moulded case circuit breaker on wall or on existing pedestal including bonding to earth and necessary connections ( HSR - 31.69 ) ( CP - 0% ) v) 4 Pole MCCB 100 amp. | BI01010001010000000000000515BI0100001536 | 3 | Each |
| 426 | 426 | vi) 4 Pole MCCB 200 amp. | BI01010001010000000000000515BI0100001537 | 2 | Each |
| 427 | 427 | vii) 4 Pole MCCB 300 to 400 amp. | BI01010001010000000000000515BI0100001538 | 1 | Each |
| 428 | 428 | Supply and erection of heavy duty Four pole on load changeover load break switches 63 to 400 amp. suitable for operation on 415 V 50 HZ AC supply complete with handle assembly having door interlock & padlocking arrangements on existing panel/ including making necessary connections with petty material required to complete the job. ( HSR - 31.74 ) ( CP - 0% ) v ) 400 amp., 4pole on load change over switch | BI01010001010000000000000515BI0100001539 | 1 | Each |
| 429 | 429 | Total Electrical HSR + CP Amount(Part -A) | BI01010001010000000000000515BI0100001540 | ||
| 430 | 430 | NS Part Electrical Work ( Part - B ) | BI01010001010000000000000515BI0100001541 | ||
| 431 | 431 | Wiring in 1.5 sqmm PVC insulated copper conductor cable in 25mm dia PVC conduit pipe \"Heavy gauge ISI marked including cost of PVC pipe, modular box of suitable size with modular inner and outer face plates, cu wires, switch & socket (modular type), screws, making necessory connections & testing complete in all respec as per confidential. NS 1) Fan point with 10A one way switch:- b) Medium point | BI01010001010000000000000515BI0100001542 | 19 | Each |
| 432 | 432 | c) Long point | BI01010001010000000000000515BI0100001543 | 9 | Each |
| 433 | 433 | 2) Light point 10A one way switch:- a) Short point | BI01010001010000000000000515BI0100001544 | 48 | Each |
| 434 | 434 | b) Medium point | BI01010001010000000000000515BI0100001545 | 51 | Each |
| 435 | 435 | c) Long point | BI01010001010000000000000515BI0100001546 | 77 | Each |
| 436 | 436 | 3) Twin control ligh point with 2 ways 10 amp. Single pole switch a) Short point | BI01010001010000000000000515BI0100001547 | 1 | each |
| 437 | 437 | b) Medium point | BI01010001010000000000000515BI0100001548 | 1 | each |
| 438 | 438 | c) Long point | BI01010001010000000000000515BI0100001549 | 2 | Each |
| 439 | 439 | 5) 5 pin, 10A switch and 10A socket wiring with 1.5sqmm, i/c earthing the 3rd pin with 1.5 sqmm copper earth wire a) Short point | BI01010001010000000000000515BI0100001550 | 2 | each |
| 440 | 440 | b) Medium point | BI01010001010000000000000515BI0100001551 | 3 | each |
| 441 | 441 | c) Long point | BI01010001010000000000000515BI0100001552 | 60 | Each |
| 442 | 442 | 6) 5 pin, 20A switch and 16A socket wiring with 4 sqmm PVC insulated copper conductor cable i/c earthing the 3rd pin with 4.00 sqmm copper earth wire a) Short point | BI01010001010000000000000515BI0100001553 | 2 | each |
| 443 | 443 | b) Medium point | BI01010001010000000000000515BI0100001554 | 1 | each |
| 444 | 444 | c) Long point | BI01010001010000000000000515BI0100001555 | 60 | Each |
| 445 | 445 | S/E of PVC pipe \"Heavy\" ISI marked for wiring purpose i/c PVC bends, hooks, inspection boxes etc. with all other material required to complete the job in all respect upto the entire satisfaction of Engineer in charges of work. ii) size 25 mm dia recessed | BI01010001010000000000000515BI0100001556 | 2500 | Metrs |
| 446 | 446 | ii) 25mm dia on surface | BI01010001010000000000000515BI0100001557 | 1000 | Metrs |
| 447 | 447 | iii) Size 32 mm dia recessed | BI01010001010000000000000515BI0100001558 | 50 | Metrs |
| 448 | 448 | iii) Size 40 mm dia recessed | BI01010001010000000000000515BI0100001559 | 100 | Metrs |
| 449 | 449 | S/E of ceiling fan 1200 mm w/o regulator complete with blades, canopies, shackles down rod suitable for AC 230 V, 50 HZ supply i/c erection charges with petty materials required to comlete the job .( Havell's - Make & Model - ES-50, 5* rating/ Crompton Greaves - Make & Model - High Breeze Plus ) | BI01010001010000000000000515BI0100001560 | 28 | Each |
| 450 | 450 | S/E of surface mounting LED Batten fitting 1x 20 watt, 6000 K (4 feet long), made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230 Volts, 50 HZ supply, complete in all respect.( Havell's - Make & Model - LHEWEBP7PLW022 or equivalent to other approved brands ) | BI01010001010000000000000515BI0100001561 | 58 | Each |
| 451 | 451 | S/E of surface mounting LED Batten fitting 1x 12 watt, 6000 K (2 feet long), made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230 Volts, 50 HZ supply, complete in all respect.( Havell's - Make & Model - LHEWEBP7PLW012 or equivalent to other approved brands ) | BI01010001010000000000000515BI0100001562 | 8 | Each |
| 452 | 452 | Supply and erection of, energy efficient LED >5000 K round luminaire, complete with diffuser, HF electronic driver and other material required to complete the job including fixing the same in false ceiling with required material & making necessary connections etc :- i) LED 36W (2'x2') ( Havell's - Make & Model - LHEWEBP7PN1W036 Pluto Flat Panel or equivalent to other approved brands) List of HPHC (Recessed) | BI01010001010000000000000515BI0100001563 | 48 | Each |
| 453 | 453 | Supply and erection of Sparkle Pro 45 watt or above downlighter with all alied items with Driver . Make Havels or equilent model of Wipro,CG of approved brand list | BI01010001010000000000000515BI0100001564 | 60 | Each |
| 454 | 454 | S/E of ISI marked propeller type ventilation fans (Exhaust Fan) Size 300 mm, 1400 rpm suitable for single phase A.C. 230 volts ,50 HZ supply, A.C. Capacitor run confrering to IS: 23/2/67, complete with mounting ring with four nos. Fixing holes without regulator as per rate contract specifications with all labour and petty material required (Havell's-Make, Model-Torboforce/ Crompton Greaves-Make, Model-Heavy Duty.) | BI01010001010000000000000515BI0100001565 | 10 | Each |
| 455 | 455 | Supply, Testing & Commissioning of wall fan 16\" sweep (400mm) Oscillating type complete with built-in regulator (PLATINA-Havells make/ Crompton Greaves Make & Model High FLO-LG white). The fan is to fixed on wall with suitable fixing arrangement including connection from nearest light point with cost of Cu wire required. | BI01010001010000000000000515BI0100001566 | 9 | Each |
| 456 | 456 | S/E of heavy duty wall fan of size 600 mm sweep alluminium alloy single piece blade sturday in construction heavy duty motor with 2 pre lubricated ball bearing precession built mecanism with indexing option 90 degree oscillation suitable for single phase 230 volts, 50 Hz, 1440 RPM, low power consumption complete with all accessories and petty meterial required etc.( Make : Orient (Tornado), Havell's, Crompton, Almonard ) | BI01010001010000000000000515BI0100001567 | 18 | Each |
| 457 | 457 | S/E PVC batten/channel with all petty material like rawal plug,wooden steek screw etc.ISI marked.(Diplast,Polycab,Polypack,Anchor,SSK) i) size 38 mmx16 mm | BI01010001010000000000000515BI0100001568 | 50 | mtr |
| 458 | 458 | ii) size 25mmx16mm | BI01010001010000000000000515BI0100001569 | 30 | mtr |
| 459 | 459 | S/E of rubber mat of size 1 mtrx2 mtrx12 mm thick 11 Kv duly tested for 15 KV ISI marked(Heavy Duty) | BI01010001010000000000000515BI0100001570 | 3 | each |
| 460 | 460 | S/E of fire existing ushers ISI marked CO2 type of 6.8 kg capacity as per IS 7285 duly erected/hanged on wall with hook i/c the cost of hook, screws etc. with all labour and material required to complete the job in all respect to the entire satisfaction of the E-I-C of the work. Make : Minimax,Safex,Vijay,Cease fire,Zenith. | BI01010001010000000000000515BI0100001571 | 3 | each |
| 461 | 461 | ii) ABC type 4.0 Kg. Capacity | BI01010001010000000000000515BI0100001572 | 2 | each |
| 462 | 462 | iii) ABC type 2.0 Kg capacity | BI01010001010000000000000515BI0100001573 | 6 | each |
| 463 | 463 | SITC of Portable Watermist 6 ltr Fire Extinguisher (For Class A,B,C as well as Electrical Started Fire (Multi purpose) | BI01010001010000000000000515BI0100001574 | 6 | each |
| 464 | 464 | SITC of Portable Watermist 2 ltr Fire Extinguisher (For Class A,B,C as well as Electrical Started Fire (Multi purpose), | BI01010001010000000000000515BI0100001575 | 6 | each |
| 465 | 465 | Supply and erection of 75mm dia GI pipe (midium) ISI marked including bends inspection boxes etc where necessary and painting as required to complete the job with all labour and petty material. NS | BI01010001010000000000000515BI0100001576 | 12 | Metrs |
| 466 | 466 | S/E of LED flood lights 180/200 watt, sutable for operaction on 230 volte A.c supply Havell's Make & equivalent in other approved brands) | BI01010001010000000000000515BI0100001577 | 10 | No. |
| 467 | 467 | S/E of moulded case circuit breaker in existing sheet steel enclosure/ L.T. panel/ Pedestal complete in all respect including bonding to earth and making necessary connections etc. (ii) Four pole, 600 amp, 415 volts, 50 K.A., adjustable thermal & fixed magnetic setting | BI01010001010000000000000515BI0100001578 | 2 | Each |
| 468 | 468 | Supply and rection of vertical double door sheet enclosure distribution board (IP 43) suitable for MCCB as incomer recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in charge of the work. b) 8 way, TPN (Vertical, MCCB provision as incomer and provision for 24 Nos. 6A-30A MCB SP as outgoings) | BI01010001010000000000000515BI0100001579 | 2 | No. |
| 469 | 469 | S/E of water cooler of stainless steel body with 150 ltr storage & cooling capacity (make -USHA,Sidwal,Voltas) &Water purifier of 40 ltr.(make-Kent) with all petty material | BI01010001010000000000000515BI0100001580 | 2 | Each |
| 470 | 470 | SITC of Main PCC cum DG Syn.Panel with APFC Capacitor Panel-100 KVAR with all alied items complete in all respect up to entire satisfaction of EIC of the work as per specification given Below. (Make:- Advance, Tricoilte, Unitech, Siemens, Indo Asian) | BI01010001010000000000000515BI0100001581 | 1 | Each |
| 471 | 471 | INCOMING SUPPLY-1 & 2 ( FROM EB & DG ),400A, 4P. 36KA MCCB with Adjustable Microprocesser Based Release having O/L,S/C, protections, ROM & Spreader Link,400A, 4P ATS ,Multifunction Meter \nIndication Lamp R-Y-B.\nIndication Lamp On-Off-Trip\nControl MCB 2A SP.10KA.\"C\"Curve.\nCTs 400/5A For Metering\nUnder Voltage Trip Coil\nShunt Trip Coil\nAuxilary Contacts\nMechanical Lock\nControl Terminals\nNeutral Link\nCT Shorting Link\nUnder & Over Volatge Relay\nRestricted E/F Relay\n | BI01010001010000000000000515BI0100001582 | ||
| 472 | 472 | AMF RELAY\nOUT GOING FEEDERS:- \n250A 3P. MCCB FEEDER- \n250A, 3P. 36KA MCCB with Adjustable Microprocesser Based Release having O/L,S/C, protections, ROM & Spreader Link\nAux. Contact Block\nMultifunction Meter\nIndication Lamp On-Off\nControl MCB 2A SP.10KA.\"C\"Curve.\nCTs 250/5A For Metering\nCT Shorting Link\nControl Terminals\nNeutral Link\n160A 3P. MCCB FEEDER-\n160A, 3P. 25KA MCCB with Adjustable Thermal Magnetic Based Release having O/L,S/C, protections, ROM & Spreader Link\nAux. Contact Block\nMultifunction Meter\nIndication Lamp On-Off\nControl MCB 2A SP.10KA.\"C\"Curve.\nCTs 160/5A For Metering\nCT Shorting Link\nControl Terminals\nNeutral Link | BI01010001010000000000000515BI0100001583 | ||
| 473 | 473 | 100A 3P. MCCB FEEDER-\n100A, 3P. 25KA MCCB with Adjustable Thermal Magnetic Based Release having O/L,S/C, protections, ROM & Spreader Link\nAux. Contact Block\nMultifunction Meter Indication Lamp On-Off\nControl MCB 2A SP.10KA.\"C\"Curve.\nCTs 100/5A For Metering\nCT Shorting Link\nControl Terminals\nNeutral Link\n63A 3P. MCCB FEEDER- FOR LIFT & ATM\n63A, 3P. 25KA MCCB with Adjustable Thermal Magnetic Based Release having O/L,S/C, protections & ROM\nAux. Contact Block\nMultifunction Meter\nIndication Lamp On-Off\nControl MCB 2A SP.10KA.\"C\"Curve.\nCTs 63/5A For Metering\nCT Shorting Link\nPower Terminal Block\nControl Terminals\nNeutral Link\nPanel (2075X2100X500 mm Appx.) | BI01010001010000000000000515BI0100001584 | ||
| 474 | 474 | \nPowder Coated Enclosure made out of TATA make CRCA sheet having 2 mm for load bearing surfaces & 1.6 mm for non load bearing surfaces ,duly 7 Tank processsed powder coated having Siemens grey colour.\nAluminium Bus Bar 400A TPN Electrolite grade E91 having cross section 1X50X10 mm for Phase & 1X50X6 mm for Neutral & Current carring capacity 0.8 A/Sq. mm2\nComplete Wiring\nHarware,Accessories etc.\nLabour\n\n | BI01010001010000000000000515BI0100001585 | ||
| 475 | 475 | Total NS Electrical (Part -B) | BI01010001010000000000000515BI0100001586 | ||
| 476 | 476 | Stage Lighting ( Part - C ) | BI01010001010000000000000515BI0100001587 | ||
| 477 | 477 | SITC of FOH Motorized Hoisting System for Stage Lighting Set Bars Made of 40 NB dual barel fo 2mm thickness, painted and provided with 2 HP, 1 Phase AC motor with cromption/ godrej flange mounted on catwalk/Angle iron frame with requisite size of necessary pulleys, guide pulleys with GI wire rope of minium 6 mm in Dia constructed with 6 Bundles of 19 stands with fibre core at centre, winding drum, specially designed compact worm gear box, upper and lower limit controller, Motor Cable Termination box etc. Control Panel.with all alied item for erection as per sectification of EIC\nPreffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001588 | 1 | Each |
| 478 | 478 | SITC of Stage Motorized Hoisting System for Stage Lighting Set Bars Made of 40 NB dual barel fo 2mm thickness, painted and provided with 2 HP, 1 Phase AC motor with cromption/ godrej flange mounted on catwalk/Angle iron frame with requisite size of necessary pulleys, guide pulleys with GI wire rope of minium 6 mm in Dia constructed with 6 Bundles of 19 stands with fibre core at centre, winding drum, specially designed compact worm gear box, upper and lower limit controller, Motor Cable Termination box etc. Control Panel.with all alied item for erection as per sectification of EIC.\nPreffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001589 | 3 | Each |
| 479 | 479 | SITC of Side Ladder: The light ladder is a metal frame designed to hold lights below a pipe. These frames look like a ladder. They are hung via their own C-clamp from a flying or fixed pipe over the stage. You can then mount lights for side lighting on the ladder. P/f of the side ladders made out of 50 X 25mm MS tube pipe size: 4x2 ft. with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA. | BI01010001010000000000000515BI0100001590 | 6 | Each |
| 480 | 480 | SITC of 100W LED Fresnel Spot Light with DmX 3200K or 5600K Code : LK F100 T/D 100W fresnel Light 3200K / 5600K colour temperature.High quality uniquely designed Fresnel Lens.Flood and Spot Manual beam Focus.CRI,TLCI and R9 value above 95.manual and DMX control Option mode through 5pin/3pin xlr.black powder coated fabricated housing with normal yoke but without accessories.with all alied item for erection as per sectification of EIC.Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001591 | 10 | Each |
| 481 | 481 | SITC of Stage Fog Machine: Heat up Time: 10minutes\nStable function. Modern designed fog machine (with/without spray adapter).\nCircuitry Control\nRemote Control\nTank Capacity: 2L\nApprox. Fog Projection: 12meters\nOutput: 20000cu.ft/min\nVoltage: AC110V?220~250V 50/60Hz\nHeater: 1500W\nWeight: 6kg\nSize: 46.5×22.5×19.5cm with all alied item for erection as per sectification of EIC Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001592 | 2 | Each |
| 482 | 482 | SITC of 100W LED Colour Corrected Multi 10 Light (Flood or Spot) with DmX 3200K or 5600K Code : LK LED M-10 100W LED Multi 10 Light complete with 3200K / 5600K 100W Lamp , DmX 512 dimming from 100 to 0% , Black finish housing, having I but without accessories. with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001593 | 24 | Each |
| 483 | 483 | SITC of 200W LED Profile Spot 3200K 19 Degree Code : LK PRO 319 T/D\n200W LED profile Light 19 degree 3200K color temperature with High quality parameters of CRI & TLCI Luminaire provided with gel holder, Gobo holding. 3 Channel DmX Control with Master Slave & Manual adjustment. with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001594 | 6 | Each |
| 484 | 484 | SITC of 400W LED Follow Spot Light Code : LK FLW 400 450W LED Follow Spot Light with daylight 450W COB 6500K White LED source having 5 Colors inbuilt, fader based intensity control, dimming and irish effects.Channel DmX Control, Manual Control Panel - Faders with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001595 | 1 | Each |
| 485 | 485 | SITC of 200W LED Blinder Light 2x100 Code : LK BLDR 2100 200W LED Blinder Light 30 Degree complete with 3200K/5600K CCT 2x100W Chip On Board LED Lamp source, DmX 512 dimming with 4 /8 Channel modes, Black finish housing, IP20 protection having Strobe option and smooth dimming, illuminate Stage with uniform light intensity levels. with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001596 | 6 | Each |
| 486 | 486 | SITC of 100W LED Parcan Light 3200K CCT Code : LK CCT PAR100 100W High Quality LED parcan Light complete with COB Lamp source 3200K CCT Colour temperature, CRI & TLCI Values above 90, DmX 512 dimming with 2 channel conmtrol, Beam Angle of 9 Degree, Black powder coated housing having IPX4 rating protection against water spray, Lux @ 2 Mtrs above 40,000 suitable for Stage lighting to illuminate the key areas.with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001597 | 24 | Each |
| 487 | 487 | SITC of 100W LED planoconvex Spot Light 100W planoconvex spot light , Imported socket and lense,bottom sliding knob,yoke with colour frame fabricated housing with plug and normal yoke and accessories.3200K color temperature with High quality parameters of CRI & TLCI Luminaire DmX Control with Master Slave & Manual adjustment with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001598 | 8 | Each |
| 488 | 488 | SITC of 8 Channel DmX Splitter Opto isolated RDM enabled DmX splitter unit complete with Power In and safety fuse, 4 Output channels 3 Pin XLR in and out supporting DMX operation as per DmX 512 protocol.with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001599 | 8 | Each |
| 489 | 489 | SITC of 2048 Channel Pearl 2010 Controller DmX Controller 2048 Channel Universes with 5/3 pin DmX Out connectors, In built Fixture library, Digital display, Display intensity control,Master fader for intensity master control, Page selction roller, Direct access to individual fixture with allocated fader,Inport export of show files. with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001600 | 1 | Each |
| 490 | 490 | Supply, Installation, Testing & Commissioning of Wiring for Direct Points Using PVC Insulated Finolex 1.5 sqmm 3Core FRLS Cu.Cond. cable for 2 sockets/box ; Core FRLS Cu.Cond. cable for 2 sockets/box ; starting from the supplied MCB Box/Panel, having 10A SP MCBs, to the Lighting bars/tree or stage points ; terminated at junction box with 2 x SHUCKO 16 Amp. Sockets/per point (all points to be marked & numbered) with all alied item for erection as per sectification of EIC.Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001601 | 78 | Each |
| 491 | 491 | Supply, Installation, Laying, Testing & Commissioning of DMX Data Signal Point Wiring : Using 2-core PVC insulated 22AWG multi-stranded Cu.Cond. high speed data cable designed for EIA485 ; lowcapacitance, twisted pair shielded ; FHDPE insulation - starting from DMX Splitter to each Light Bar - either sides, Side Ladders and Floor Points, as required to be terminated with suitable XLR connectors with all alied item for erection as per sectification of EIC. Preffered Make: OPAL LIGHT / STAGE WORKS / ILLUMITEX / CANARA | BI01010001010000000000000515BI0100001602 | 78 | Each |
| 492 | 492 | Total Stage Lighting NS (Part-C) | BI01010001010000000000000515BI0100001603 | ||
| 493 | 493 | Audio & Video System ( Part - D) | BI01010001010000000000000515BI0100001604 | ||
| 494 | 494 | NS Items | BI01010001010000000000000515BI0100001605 | ||
| 495 | 495 | SITC of dual 15\" two way loudspeaker. Loudspeaker: 38Hz-20KHz (-10dB), Max SPL 137 dB SPL or more. Wideband Coverage (HXV) 90X50 degrees or better. It should have Axial Sensitivity of >96dB with 600watts cont. peak power handling of >2400 W. Make Electro-Voice Model-ELX215,Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001606 | 2 | each |
| 496 | 496 | SITC of Stage Monitor speaker with in-built amplifier\nhaving 12\" LF ,1\" or more HF with frequency range of\n55Hz - 20kHz (-10dB) or better deliviering a max SPL\n131dB SPL .It should have horizontal and vertical\ncoverange angle of 90 degree and 50 degree or\nbetter.The loudspeaker should have inbuilt amplfier of\nclass D delivering a power of 950W or more.It should\nhave integrated monitor angle on the enclosure for use\nfloor monitor Make Electro-Voice Model ELX112P Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001607 | 2 | each |
| 497 | 497 | SITC of 18\" Subwoofer with Frequency Range(-10dB):- 40-150Hz delivering a Max SPL of 132dB or more. It should have a Cardioid Coverage Pattern with a Built in Class D Amplifier of 1300W Power Rating or better Make Electro-Voice Model-EKX18SP Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001608 | 2 | each |
| 498 | 498 | SITC of Two-Way Speaker, Frequency Range(-10dB):- 60Hz-18KHz with 12\" LF Driver having a continous Power Handling>250W. It Should have a Axial Sensitivity (1W/1m) of 95dB & delivering a Max. SPL of atleast 125dB with HXV Coverage of 90 x 50 Degrees or better. Make Electro-Voice Model-ZLX12 Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001609 | 4 | each |
| 499 | 499 | SITC of OEM Bracket for Above Balcony Speakers Make Electro-Voice Model-ZLX-BRKT Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001610 | 2 | each |
| 500 | 500 | SITC of Wall Mount Loudspeaker with Single 5.25\" or better LF Driver with Frequency Response:- 85 - 20000 ±3 dB. The Speaker should have a RMS Wattage of >=110W & Sensivity (1W/ 1m) >=85dB with a Sound Dispersion of 100x20 Degrees or better Make Electro-Voice Model-S-40B Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001611 | 2 | Pairs |
| 501 | 501 | SITC of OEM Bracket for Front Fill Speakers Make Electro-Voice Model-S-40MBB Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001612 | 4 | each |
| 502 | 502 | SITC of High efficiency power and performance innovative Class H design 1250 W per channel 2 ohms dynamic headroom for all real world applications XLR pass through input connections, continuous rated power (1 Khz THD 1%) 2 Ohms 1250 watts 4ohms 900 watts 8 ohms 550 watts. Max bridge output 4 ohm 2800 watts max bridge output 8 ohm 1800 watts signal to noice ratio (A weighted) 109dB, Topology class H Make Electro-Voice Model-Q99 Equivalent model of crown,,Martin audio | BI01010001010000000000000515BI0100001613 | 2 | each |
| 503 | 503 | SITC of 650 watts per channel power amplifier XLR pass through input connection built in dynamic limiters, continuous rated power (1KHZ THD 1%) 2 ohm 650 watts 4 ohms 450 watts 8 ohms 270 watts max. bridge output 4 ohm 1300 watts max bridge output 8 ohm 900 watts signal to noice ratio 106dB Make Electro-Voice Model- Q44-II Equivalent model of Crown,Martin audio | BI01010001010000000000000515BI0100001614 | 2 | each |
| 504 | 504 | SITC of Corded Vocal Microphone with Dynamic Neodymium Magnet microphone element,with frequency response 80 Hz - 16,000 Hz,Super-Cardioid polar pattern,sensitivity of 2.2mV/Pa and output impedence 600 ohm Make Electro-Voice Model-PL80A Equivalent model of SHURE,Sennheiser | BI01010001010000000000000515BI0100001615 | 2 | each |
| 505 | 505 | SITC of Corded Instrument Microphone with Self Biased condensor microphone element ,with frequency response of 50 Hz - 16,000 Hz ,Cardioid polar pattern,sensitivity of 6.0mV/Pa ,rated impedence of 200 ohm ,maximum spl >=132dB SPL and dynamic range ;107dB Make Electro-Voice Model-PL37 Equivalent model of studio master. | BI01010001010000000000000515BI0100001616 | 2 | each |
| 506 | 506 | SITC of Handheld Wireless Mic system with Cardiod polar pattern,Dynamic microphone ,frequency response 83Hz-18kHz,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 30 channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,modulation:+/-40kHz Make Electro-Voice Model-R300-HD-A Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001617 | 1 | each |
| 507 | 507 | SITC of Freestanding Gooseneck Mic with base for podium having back electret condensor microphone element ,Hyper Cardioid polar pattern,programmable switch for Push to Talk or Push to Mute,LED mic status display,frequency response 50 - 20,000 Hz ,sensitivity 5.5mV/Pa,clipping level >130dB SPL ,output impendence 200 ohm. Make Electro-Voice Model-PC DESKTOP-18 Equivalent model of AKG/ SHURE | BI01010001010000000000000515BI0100001618 | 1 | each |
| 508 | 508 | SITC of 16 channel mixer Outstanding microphone preamps\nSwitchable Phantom Power & PAD Switch\n1-knob Compressors\nEQ and High-pass Filters\nAUX / Effect Sends / Group\nLED level metering\nBuilt-in SPX Digital Effects\nMetal Chassis\nUSBBPOQ make Yamaha Model-MG16XU,equivalent model of Electro Voice,Mackie | BI01010001010000000000000515BI0100001619 | 1 | each |
| 509 | 509 | SITC of Digital Signal Processor with 2 x XLR IN, electronically balanced audio input,6 x XLR OUT, electronically balanced audio output with 2 x XLR Thru out ,and 1x XLR AES/EBU IN digital input,with Nominal Input Voltage:1.23V / +4 dBu, maximum input voltage:8.7V / +21 dBu,input impedence :10k Ohm,CMR:-80dB@1kHz,A/D &D/A coversion :24 bit sigma delta,THD+N <0.01% Make Electro-Voice Model-DC ONE Equivalent model of JBL,Martin audio | BI01010001010000000000000515BI0100001620 | 1 | each |
| 510 | 510 | SITC of Laser single chip DLP projector without lens having following specification. 1.Image brightness 6700 Lumens 2. Dynamic contract ratio 6000:1. 3. Native resoluction 1920x1200(WUXGA). 4. Display 1 x 0.67\" DMD 5. IIumnation type - Blue Laser Phosphor 6. Estimated life - 20000hrs. 7. Inputs HDMI x2 DVI-x1 (digital only),HDI5 x 1, RJ45 x1 8. Control - Built-in backlist keypad and IR remote. 9. Lens mount type - Motorized horized (+/-15% Horizotal ) and Veritcal (+/-50%, Vertical) lens offset 10 Motorized zoom and focus adjustment complete in all repect including petty matical and making neccessary connections etc.(Model - DWU630-GS WUXGA, Make chrisite and equivalent in Barco or DPI | BI01010001010000000000000515BI0100001621 | 1 | each |
| 511 | 511 | SITC of Long throw Projector lens suitable for above said projector Make: Chrisite, Barco DPi | BI01010001010000000000000515BI0100001622 | 1 | each |
| 512 | 512 | SITC of Multi Input Box with 2X HDMI, 2 XVGA, 1X S Video & 1 X Video Inputs and One LAN Output. The Output should be integrated in the projector with no external Hardware. The entire solution shall be One Single Box. Makes: Panasonic Model YFB-100 OR Equivlant model of KRAMER | BI01010001010000000000000515BI0100001623 | 1 | each |
| 513 | 513 | SITC of perforated type Equipment Rack suitable to accommodate the above said equipments with power strip,exhaust etc. | BI01010001010000000000000515BI0100001624 | 1 | each |
| 514 | 514 | SITC of 2 core 2.5 sqmm speaker cable with high end transparent speaker cable for long distance.(Beldon,kramer,krystal) | BI01010001010000000000000515BI0100001625 | 200 | Mtr. |
| 515 | 515 | SITC of of double protection speaker cable for fantastic sound quality,use for audio applications with double protection.(Beldon,kramer,crystal) | BI01010001010000000000000515BI0100001626 | 400 | Mtr. |
| 516 | 516 | SITC of XLR Connectors (amphenol,neutrik,mx) | BI01010001010000000000000515BI0100001627 | 100 | Set |
| 517 | 517 | SITC of Speaker Connectors (amphenol,neutrik,mx) | BI01010001010000000000000515BI0100001628 | 100 | Set |
| 518 | 518 | SITC of Mounting Arrangment for Main FOH- Speakers | BI01010001010000000000000515BI0100001629 | 2 | each |
| 519 | 519 | SITC of RGB cable (kramer,krystal,falcon) | BI01010001010000000000000515BI0100001630 | 60 | Mtr. |
| 520 | 520 | Long Stands | BI01010001010000000000000515BI0100001631 | 2 | each |
| 521 | 521 | SITC of Stage snake drum wire 8 channel long drum (Belton,kramer,Krystal) | BI01010001010000000000000515BI0100001632 | 200 | Mtr. |
| 522 | 522 | SITC of xlr cable (Belton,kramer,Krystal) | BI01010001010000000000000515BI0100001633 | 100 | Mtr. |
| 523 | 523 | Total of Part (D) | BI01010001010000000000000515BI0100001634 | ||
| 524 | 524 | Part E - VRV system(HSR+CP) Part(E) | BI01010001010000000000000515BI0100001635 | ||
| 525 | 525 | Supply and erection of moulded case circuit breaker on wall or on existing pedestal including bonding to earth and necessary connections:-. (HSR 31.12) (CP 60%) | BI01010001010000000000000515BI0100001636 | ||
| 526 | 526 | i) 15 amp. To 60 amp. 415V 10 K.A 3 phase | BI01010001010000000000000515BI0100001637 | 9 | Each |
| 527 | 527 | ii) 100 amp. To 220 amp.415V 10 K.A | BI01010001010000000000000515BI0100001638 | 1 | Each |
| 528 | 528 | iv) 500 amp. To 600 amp. 415V 35 K.A3 phase | BI01010001010000000000000515BI0100001639 | 1 | Each |
| 529 | 529 | Control /Power Cabling HSR 31.9 CP-130% Supply Erection and commissioning of copper wiring. b) 2 x 0.75 sqmm copper wire HSR 31.9 CP-130% | BI01010001010000000000000515BI0100001640 | 140 | R/Mt |
| 530 | 530 | EARTHING:- (HSR 31.22) (CP 350%) i)Earthing with G.I earth pipe 4.5 mm long and 40 mm dia with masonry enclosures on the top etc as required. | BI01010001010000000000000515BI0100001641 | 9 | Each |
| 531 | 531 | ii)Extra for using salt and charcoal/coke for for pipe earth electrode as required. | BI01010001010000000000000515BI0100001642 | 9 | Each |
| 532 | 532 | xiiiPdg. and laying earth connections from earth electrode with 4.00 mm dia G.I wire in 15 mm dia G.I. pipe from earth electrode as required. | BI01010001010000000000000515BI0100001643 | 40 | mtr |
| 533 | 533 | xvi)Pdg. and fixing 4.00 mm dia G.I. wire on surface or in recess for loop earthing as required. | BI01010001010000000000000515BI0100001644 | 60 | mtr |
| 534 | 534 | iii) Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing enclosures accessories and providing enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. | BI01010001010000000000000515BI0100001645 | 1 | Each |
| 535 | 535 | v) Extra for charcoal or coke and salt for GI plate or copper plate earth electrode. | BI01010001010000000000000515BI0100001646 | 1 | Each |
| 536 | 536 | xv) Pdg. and fixing 25 mm x 5 mm G.I strip on surface or in recess for connection etc. as required with all labour and material | BI01010001010000000000000515BI0100001647 | 30 | mtr |
| 537 | 537 | Supply and erection of Al. Armoured under ground cable, loose in existing pipe or trenches complete with necessary connections:- HSR 31.26 CP-140% (xxv) 25 sq mm 3 ½ Core cable | BI01010001010000000000000515BI0100001648 | 240 | R/Mt |
| 538 | 538 | (xxvi) 35 sq mm 3 ½ Core cable | BI01010001010000000000000515BI0100001649 | 30 | R/Mt |
| 539 | 539 | (xxix) 95 sq mm 3 ½ Core cable | BI01010001010000000000000515BI0100001650 | 20 | R/Mt |
| 540 | 540 | Supply installation testing and commissioning of wall/ free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2mm thickCRCA sheet, required hardware, 3mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel, dully painted by 2 coat of zinc/ red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/ Neroprene rubber gasket of not less than 3mm thickness, separate detachable gland plate MS base channel, hinged door with inter locking arrandement for equipment/ switch gear.Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3mm thick for separately cable alley to BBC from switch chember. Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cble alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring(copper) and fuse protection. (only outer area on all sides shall be measured) (HSR 31.63) (CP 0%) | BI01010001010000000000000515BI0100001651 | 14.9 | sqm |
| 541 | 541 | Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle from frame including bonding, detachable top and bottom including painting and necessary connections etc. (Aluminium bars).(HSR 31.32) (CP-175%) 300 amp. 4 bars of 100 cm each (cross Section 51 mm x 6 mm ), chamber over all size 1.10 m x 55 cm x 23 cm HSR 31.32(IX)CP175% | BI01010001010000000000000515BI0100001652 | 2 | each |
| 542 | 542 | P/F digital metering equipment for LT cubical panel consisting of 96mmx96mm 0-500V, volt meter with selector switch, Amp. Meter ( of required ratio up to 600/5 amp.) with selector switch and required C.Ts 3 nos,. A set of 3 no phase indicating lamps RYB LED.(HSR 31.65) (CP 0%) | BI01010001010000000000000515BI0100001653 | 1 | each |
| 543 | 543 | S/F of rotary handle for on/ off operation of existing MCCB in the LT panel i/c fixing the same in position with all labour and material required to complete the job in all respect.(HSR 31.66) (CP0%) Rotary handle up to 125A.MCCB | BI01010001010000000000000515BI0100001654 | 10 | each |
| 544 | 544 | Rotary handle above 125A.MCCB | BI01010001010000000000000515BI0100001655 | 1 | each |
| 545 | 545 | Total NS Items VRV System(HSR+CP) Part E | BI01010001010000000000000515BI0100001656 | ||
| 546 | 546 | VRF UNITS & AHU Unit:-PART (E)NS | BI01010001010000000000000515BI0100001657 | ||
| 547 | 547 | Supply, Installation Testing and commissioning of Variable Refrigerant Volume type multi compresser air-conditioning system complete with indoor and outdoor units with central individual controller etc as per details Below. The units shall beHeat Pump type and shall be capable of providing both cooling/ heating including the cost of Filling of Refrigerant gas 410a.specifications.Cop 3.5@ 100% loading ( Mitsubishi, Daikin, O-General / Toshiba) | BI01010001010000000000000515BI0100001658 | ||
| 548 | 548 | OUTDOOR | BI01010001010000000000000515BI0100001659 | ||
| 549 | 549 | Supply and installation of Modular type outdoor multi compresser equipped with highly efficientRotary/scroll compressors, with Inverter, special acryl pre-coated heat exchanger, low noise condenser fan, auto check function for connection error etc, centralize controller for individual control complete as per OEMspecifications of Following Capacity. Cost shall include Hoisting, Installation Testing and Commissioning of all the VRV/VRF at site including Full Gas charging with environment friendly Refrigerant including Cost of Refrigerant. | BI01010001010000000000000515BI0100001660 | ||
| 550 | 550 | 60 HP- | BI01010001010000000000000515BI0100001661 | 1 | each |
| 551 | 551 | 40 HP- | BI01010001010000000000000515BI0100001662 | 2 | each |
| 552 | 552 | 10 HP- | BI01010001010000000000000515BI0100001663 | 1 | each |
| 553 | 553 | 16 HP- | BI01010001010000000000000515BI0100001664 | 1 | each |
| 554 | 554 | AHU KIT-Control Floor Mounted Horizontal AHUs 60 HP | BI01010001010000000000000515BI0100001665 | 1 | each |
| 555 | 555 | 40 HP | BI01010001010000000000000515BI0100001666 | 2 | each |
| 556 | 556 | 16 HP | BI01010001010000000000000515BI0100001667 | 1 | each |
| 557 | 557 | Indoor unit 6.6 Tr High static ductable type concealed unit | BI01010001010000000000000515BI0100001668 | 1 | each |
| 558 | 558 | Supplying , Installaing , Testing and Commissioning of double skin air handling units (AHUs) each comprising of following as per the specifications, Casing of air handling units shall be in double skin construction. Inner skin shall be constructed out of 24 gauge plain GS sheet & outer skin in 24 gauge preplasticized GS sheet sandwitched between 25mm thick injected PU foam insulation of density not less than 40 Kg /CuM and complete with inspection doors and marine light,limit switch including control wiring as required. Multiblade box type mannualy operated aluminium dampers shall be factory fitted at each outlet of centrifugal fan. Fan section complete with forward curved DIDW type centrifugal fan/s class EFF1 type twin TEFC squirrel cage induction motor suitable to operate on 415+10%V, 50Hz,3 phase AC power supply and belt drive package Fan outlet velocity shall not be more than 2000 FPM (10.16 MPS) Coil section with multirows deep DX type coil of copper tube and aluminium fins construction having wall thickness of tubes not less than 1mm. Copper Coil shall be tested for minimum 600 psi pressure for 24 hrs for leakage. Drain pan shall be made out of 18 gauge G.I. duly insulated. Face velocity across cooling coil shall not exceed 500FPM. Filter section complete with 50mm thick washable synthetic fibre filters and 150mm micron filter Velocity across the filters shall not exceed 500 FPM. Air Handling unit shall be equiped with Electronic Expansion Valve which canvary its capacity based on variable loads. In addition to the above, air handling units shall be provided with adequate vibration isolation pads and fire retardent flexible canvass connections made out of canvass sleeve. Sizes of air handling units shall not exceed as mentioned in the design drawings and air handling units shall conform to the design parameters mentioned in specifications. The Air Handling Units (AHUs) shall be of following duty parameters : | BI01010001010000000000000515BI0100001669 | ||
| 559 | 559 | FMAHU: 18000 CFM 50 mm static, 6 row deep Coling Coil | BI01010001010000000000000515BI0100001670 | 1 | each |
| 560 | 560 | FMAHU: 15000 CFM 50 mm static, 6 row deep Coling Coil | BI01010001010000000000000515BI0100001671 | 1 | each |
| 561 | 561 | Main Auditorium ,stage,Entrance Ground block FMAHU: 6000 CFM 10 mm static, 6 row deep Coling Coil | BI01010001010000000000000515BI0100001672 | 1 | each |
| 562 | 562 | Balcony Block FMAHU: 15000 CFM 50 mm static, 6 row deep Coling Coil | BI01010001010000000000000515BI0100001673 | 1 | each |
| 563 | 563 | Installation, Testing and Commissioning, of Ref Nets & outDoor Twining Kits | BI01010001010000000000000515BI0100001674 | 10 | No |
| 564 | 564 | Supply,installation testing and commisioning of extruded aluminum powder coated Jet nozzles,18 '' Dia | BI01010001010000000000000515BI0100001675 | 60 | No |
| 565 | 565 | REFRIGERANT PIPING | BI01010001010000000000000515BI0100001676 | ||
| 566 | 566 | Supply, Installation, Testing and commissioning in position the following COPPER refrigerant piping of 14-22 G and fixing in position necessary fittinglike elbows, jointers and reducers complete with nitrile foam insulation of given thickness and all exp makes of pipe : Totaline, Rajco, Nissan, Mandev | BI01010001010000000000000515BI0100001677 | ||
| 567 | 567 | 44.45 mm OD(insulation = 19 mm thick) Rmt | BI01010001010000000000000515BI0100001678 | 15 | mtr |
| 568 | 568 | 38 mm OD( insulation = 19 mm) Rmt | BI01010001010000000000000515BI0100001679 | 18 | mtr |
| 569 | 569 | 34.9 mm OD( insulation = 19 mm) Rmt | BI01010001010000000000000515BI0100001680 | 15 | mtr |
| 570 | 570 | 28.6 mm OD (insulation = 19 mm) Rmt | BI01010001010000000000000515BI0100001681 | 30 | mtr |
| 571 | 571 | 22.2 mm OD (insulation = 13mm) Rmt | BI01010001010000000000000515BI0100001682 | 25 | mtr |
| 572 | 572 | 19.1 mm OD (insulation = 13 mm) Rmt | BI01010001010000000000000515BI0100001683 | 25 | mtr |
| 573 | 573 | 15.9 mm OD (insulation = 13 mm) Rmt | BI01010001010000000000000515BI0100001684 | 35 | mtr |
| 574 | 574 | 9.5 mm OD (insulation = 13mm) Rmt | BI01010001010000000000000515BI0100001685 | 30 | mtr |
| 575 | 575 | Drain Piping | BI01010001010000000000000515BI0100001686 | ||
| 576 | 576 | Providing and fixing in position the following UPVC condensate drain pipes | BI01010001010000000000000515BI0100001687 | ||
| 577 | 577 | with kinny foam insulation | BI01010001010000000000000515BI0100001688 | ||
| 578 | 578 | 40 mm dia drain pipe | BI01010001010000000000000515BI0100001689 | 30 | R/Mt |
| 579 | 579 | SHEET METAL DUCTWORK- Factory Fabricated. | BI01010001010000000000000515BI0100001690 | ||
| 580 | 580 | Supply, Fabrication, installation testing and commissioning of site fabricated GSS | BI01010001010000000000000515BI0100001691 | ||
| 581 | 581 | sheet metal ducting complete with hangers, supports and neoprene gasket sealing | BI01010001010000000000000515BI0100001692 | ||
| 582 | 582 | as per the specification and approved drawings. (Lead Free Sheet Make Tata Sail) | BI01010001010000000000000515BI0100001693 | ||
| 583 | 583 | 24 gauge GI ducting | BI01010001010000000000000515BI0100001694 | 410 | SQMT |
| 584 | 584 | 22 gauge GI ducting | BI01010001010000000000000515BI0100001695 | 330 | SQMT |
| 585 | 585 | 20 gauge GI ducting | BI01010001010000000000000515BI0100001696 | 100 | SQMT |
| 586 | 586 | Supply, installation, testing and commissioning of double canvas for outlet | BI01010001010000000000000515BI0100001697 | 4 | Nos |
| 587 | 587 | connection of the equipments. | BI01010001010000000000000515BI0100001698 | ||
| 588 | 588 | Supply, installation, testing & commissioning of extruded aluminum powder | BI01010001010000000000000515BI0100001699 | 12 | SQMT |
| 589 | 589 | coated supply/Return air grilles. | BI01010001010000000000000515BI0100001700 | ||
| 590 | 590 | Supply, installation, testing & commissioning of extruded aluminum powder | BI01010001010000000000000515BI0100001701 | 10 | SQMT |
| 591 | 591 | coated supply/Return air Diffusers | BI01010001010000000000000515BI0100001702 | ||
| 592 | 592 | Supply, installation, testing & commissioning of extruded aluminum volume | BI01010001010000000000000515BI0100001703 | 10 | SQMT |
| 593 | 593 | control damper. | BI01010001010000000000000515BI0100001704 | ||
| 594 | 594 | Supply, installation, testing & commissioning of Fire Dampers (Fusible Link), Motorized | BI01010001010000000000000515BI0100001705 | 12 | SQMT |
| 595 | 595 | Supply and Erection of 25mm thick acoustic lining with in the supply air | BI01010001010000000000000515BI0100001706 | 100 | SQMT |
| 596 | 596 | duct as per specification. With perferuated Al. sheet | BI01010001010000000000000515BI0100001707 | ||
| 597 | 597 | Supply and erection of 9 mm nitrile rubber fire retardant per the | BI01010001010000000000000515BI0100001708 | 500 | SQMT |
| 598 | 598 | specifications and drawings. | BI01010001010000000000000515BI0100001709 | ||
| 599 | 599 | Supply Instalation Testing and comissoning of central remort control unit with touch control panel. | BI01010001010000000000000515BI0100001710 | 1 | no |
| 600 | 600 | Supply and erection of cable tray with GI sheet cover for exposed piping in corridoor/false ceilling/wall hanged/ fixed with the help of fasteners& MS hanger of required size with all labour and petty material required. | BI01010001010000000000000515BI0100001711 | 55 | R/mtr |
| 601 | 601 | AHU Room Insulation | BI01010001010000000000000515BI0100001712 | ||
| 602 | 602 | SITC of acoustic insulation of the AHU rooms with 50 mm thk FG Board of density 32 kg/cum covered with FG cloth & 24 G perforated Al sheet. These shall be fitted in a GI channel section grid of size 900x900. All work shall be done as per standard engineering pratice & workmanship. The surface shall be treated with anti termite treatment before laying the above items.(MAKE: UPTWIGA) | BI01010001010000000000000515BI0100001713 | 950 | SqMtr |
| 603 | 603 | Ventilation Work | BI01010001010000000000000515BI0100001714 | ||
| 604 | 604 | Axial Flow Fan (MAKE: Kruger / Nicotra) | BI01010001010000000000000515BI0100001715 | ||
| 605 | 605 | Supplying, Installation, Testing and Commissioning of Floor standing Exhaust Air Axial flow fans of 20 mm WG static pressure complete with GSS casing , aluminium alloy impellers, directly driven by TEFC induction motor suitable for 415 V ± 10 %, 50 Hz, 3 Phase, 1450 RPM, supporting frame, Gravity louvers, weld mesh inlet guard, TP isolator with MS enclosure box as required etc. Axial fans for smoke ventilation shall be AMCA and third party certified and should have fire rated motor and fan of Class- H suitable for working at high temperature (250 deg. C for minimum 2 hrs.) | BI01010001010000000000000515BI0100001716 | ||
| 606 | 606 | 22000 CFM | BI01010001010000000000000515BI0100001717 | 4 | Nos. |
| 607 | 607 | 8000 CFM | BI01010001010000000000000515BI0100001718 | 2 | Nos. |
| 608 | 608 | *All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade. A computer printout with vibration spectrum analysis shall be attached to the fans. | BI01010001010000000000000515BI0100001719 | ||
| 609 | 609 | *Fan should be of G.S.S. , the Steel sheet should be JFE Galvazinc (Base metal cold rolled), JIS G3302, SGCC with Z22 (minimum coating weight on both sides @ 220 g/m2) zinc coating & Zero Spangle, skinpassed, chromated and dry. | BI01010001010000000000000515BI0100001720 | ||
| 610 | 610 | Toilet Exhaust System | BI01010001010000000000000515BI0100001721 | ||
| 611 | 611 | SITC of inline fans of G.I. construction complete with centrifugal fan with motor, drive, canvass connection at inlet outlet all enclosed in a 16 Ga G.I. sheet casing complete with electrical connector, cabling etc as per specification and drawings. The gravity louvers made of Al extruded sheet metal duly powder-coated shall be fixed on the outer surface of the toilet wall in a wooden frame. The power supply to the fan shall be from nearby single phase point available.(MAKE : Ostberg / Caryaire) | BI01010001010000000000000515BI0100001722 | ||
| 612 | 612 | 600 cfm, 15 mm S.P. | BI01010001010000000000000515BI0100001723 | 2 | Nos. |
| 613 | 613 | 400 cfm, 15 mm S.P. | BI01010001010000000000000515BI0100001724 | 3 | Nos. |
| 614 | 614 | SITC of Aluminium wired flexible duct complete as per specifications and drawings of dia 150 mm / 200 mm ( MAKE :- Atco ) 150 mm dia | BI01010001010000000000000515BI0100001725 | 100 | Rmt |
| 615 | 615 | 200 mm dia | BI01010001010000000000000515BI0100001726 | 100 | Rmt |
| 616 | 616 | Propeller fan for Toilets of cap. 150-200 cfm ( MAKE : Crompton / GE) | BI01010001010000000000000515BI0100001727 | 2 | Nos. |
| 617 | 617 | Electrical Panels ( MAKES:- KEPL / International / Kalyani ) Designing, fabricating, transporting to site, installing, testing and commissioning of floor mounted, self supported, compartmentalized LT cubical Panel (Extendable Type) metal clad switch board, fabricated from 2mm (14 G) thick CRCA sheet steel suitable for 31 MVA rupturing capacity at 415 V, 3 phase, 4 wire, 50 HZ AC supply and equipped with PVC sleeved aluminum bus bars of specified rating and following switch gears inter connected by PVC sleeved solid conductors, including 7-tank cleaning, degreasing, phosphating process and treatment of panel with anti-corrosive zinc based primer paint and finally powder coating the panel, complete with earthing terminals, cable and bus bar alleys and hoisting hooks as required. The LT panel will comprise MCCBs and MCBs as described below for incoming and outgoing power supplies. | BI01010001010000000000000515BI0100001728 | 1 | Set |
| 618 | 618 | INCOMING FEEDER FEATURES | BI01010001010000000000000515BI0100001729 | ||
| 619 | 619 | All the incoming circuit breakers of panels shall consist of following accessories: | BI01010001010000000000000515BI0100001730 | ||
| 620 | 620 | i. 0-500 V range voltmeter 144 x 144 mm size with\nselector switch and back up fuses. : 1 Set. | BI01010001010000000000000515BI0100001731 | ||
| 621 | 621 | ii. Suitable range of ammeter 144 x 144 mm size with selector switch and CTs as mentioned in schedule. : 1 Set. | BI01010001010000000000000515BI0100001732 | ||
| 622 | 622 | iii. Phase indicating neon lamps with MCB protection. : 3 Sets. | BI01010001010000000000000515BI0100001733 | ||
| 623 | 623 | iv. Breaker ‘ ON ’ / ‘ OFF ’ indication lamp with MCB\nprotection. : 2 sets. | BI01010001010000000000000515BI0100001734 | ||
| 624 | 624 | v. Standard trip and over load relays. | BI01010001010000000000000515BI0100001735 | ||
| 625 | 625 | vi ) Four Pole MCCB with rotary handle as incomer with copper bus bar with haet shrinkable colour coaded PVC sleeves as per actual requirement | BI01010001010000000000000515BI0100001736 | ||
| 626 | 626 | OUTGOING FEEDERS: | BI01010001010000000000000515BI0100001737 | ||
| 627 | 627 | 8 Nos 63A - MCCB for 22.0HP circuit of VRV | BI01010001010000000000000515BI0100001738 | ||
| 628 | 628 | 8 Nos 63A - MCCB for AHUs Panels | BI01010001010000000000000515BI0100001739 | ||
| 629 | 629 | MCCB & contactors for Axial flow fans of required capacity as required | BI01010001010000000000000515BI0100001740 | ||
| 630 | 630 | AHU Panel (Make: Emco/KEPL/Tricolite/ESS ESS KAY) Providing, fixing ,testing and commissioning of weather proof panel board cubical compartmentalised, wall mounted made of 1.6 mm thick steel sheet duly painted complete with Digital ammeter, indicating lights for selector switch, incoming/outgoing feeders CTS contactors for complete as per specification followng Incoming: 1 No 63 Amps TPN incoming MCCB alongwith status indicators, control fuses etc. Outgoing : 32/25Amp TP MCCB for AHU motor/ Condensing units , PAN Humidifer & strip heaters alongwith contactors, Auto/manual switch, indicators, digigal Ammeter, CT's, push buttons, selector switches, auto phase changer, auto single phase preventer system etc | BI01010001010000000000000515BI0100001741 | 8 | Nos |
| 631 | 631 | Control & Transmission Wiring | BI01010001010000000000000515BI0100001742 | ||
| 632 | 632 | SITC of control cum transmission wiring of size 1.5mm² x 2 Core shielded copper in PVC conduits of 25 mm dia Heavy ISI marked on surface between indoor and outdoor unit with suitable hangers/ saddles etc. on the existing cable trays ( MAKES:- Havell's / Achor/ HPL / POLYCAB / FINOLEX ) as per brand list | BI01010001010000000000000515BI0100001743 | 200 | Rmt |
| 633 | 633 | Power & Control Cabling | BI01010001010000000000000515BI0100001744 | ||
| 634 | 634 | Supplying/laying of following 1100 volt grade PVC insulated FRLS sheathed copper conductor armoured cables on cable trays (as per quantity of cable trays included in BOQ separately), on walls clamped to wall with suitable clamps, saddles and fixing bolts including jointing/ connecting / terminating, testing and commissioning in all respects as per the standard practice for following sizes ( Make Havell’s , Plaza, Polycab, Ecko, Finolex ) :- | BI01010001010000000000000515BI0100001745 | ||
| 635 | 635 | a ) 16 mm² x 4 core | BI01010001010000000000000515BI0100001746 | 100 | Rmt |
| 636 | 636 | b) 6 mm² x 4 core | BI01010001010000000000000515BI0100001747 | 50 | Rmt |
| 637 | 637 | c) 1.5mm² x 3 core | BI01010001010000000000000515BI0100001748 | 50 | Rmt |
| 638 | 638 | d ) 2.5mm² x 3 core | BI01010001010000000000000515BI0100001749 | 50 | Rmt |
| 639 | 639 | Earthing with 8 SWG GI wire complete with necessary hardware, thimbles duly crimped/soldered alongwith the cabling as per the route and design. | BI01010001010000000000000515BI0100001750 | 200 | Rmt |
| 640 | 640 | SITC of Refrigerant gas R-410A Charging of system after complete testing for any leaks & vacummising as per standard procedures. | BI01010001010000000000000515BI0100001751 | 1 | LS |
| 641 | 641 | EPBAX Make NEC/ PANASONIC/ AVAYA Providing & Fixing Main Distribution Frame(MDF) No of pairs: 100 pairs alongwith IPM | BI01010001010000000000000515BI0100001752 | 1 | No. |
| 642 | 642 | Providing & Fixing CLID DESK PHONE MAKE BEETELL/ PANASONIC. | BI01010001010000000000000515BI0100001753 | 10 | No. |
| 643 | 643 | NS Total PART (E)(VRF Units & AHU Units) | BI01010001010000000000000515BI0100001754 | ||
| 644 | 644 | CCTV System ( Part - F ) | BI01010001010000000000000515BI0100001755 | ||
| 645 | 645 | NS Items | BI01010001010000000000000515BI0100001756 | ||
| 646 | 646 | Supply Installation testing and Comissioning of 1080p Bullet camera with 1/2.9-inch CMOS, Total sensor pixels 1936 (H) x 1097 (V); 2.12MP (approx.), Built-in IR illuminator with 30 m (98 ft) viewing distance, Easy to install with auto zoom/focus lens, wizard and pre-configured modes, Fully configurable quad streaming, Regions of interest and E-PTZ, Shall have hybrid functionality, Sensitivity – (3200K, reflectivity 89%, F1.3, 30IRE)- Color 0.07 lx, Mono 0.05 lx, With IR 0.0 lx, 76dB WDR, True day/night, Electronic shutter, iDNR, BLC, Intelligent defog, Privacy Masking- Four independent areas, fully programmable, Full duplex / half duplex Audio Streaming, Varifocal 2.7 to 12 mm lens, Micro SD card slot, 3-axis adjustment (pan/tilt/rotation), Password protection, ONVIF Profile S, IP66, IK08, CE, FCC, UL Certified.Makes: Sony , Bosch, Siemens | BI01010001010000000000000515BI0100001757 | 6 | Nos |
| 647 | 647 | Supply of 32 Channel IP network video recorder with Camera licences supported bandwidth of 320Mbps, compression of H.265/H.264 supported, smartphone access, DDNS for remote viewing, RAID 1/RAID 5, RJ45 video input for max. 32 IP cameras, storage required 24TB\nconnected via external switch, HDMI, 16 Input alarm, 6 Output connections, eSATA, 100/240 VAC, multi channel playback 1/4/9/16 channels, HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS/DDNS, IP Filter, PPPoE, FTP , Max. 4 SATA HDD Max. capacity per HDD: 6 TB Max. supported speed per HDD: 6 Gb/s, UL listed.Makes: HP, Dell, IBM & Oem Of Cameras | BI01010001010000000000000515BI0100001758 | 1 | Nos |
| 648 | 648 | Supply Installation Testing & Commissioning of more than 43\" full HD Smart LED Display Active Matrix TFT Flat Screen . Flat Screen at high resolution 1920 × 1080 minimum. Resolution High Definition resolution of 1280 X 1024 / WXGA 1300 X 700p or better. Input HDMI 2 NO, USB 1 NO, RCA phono type x 2 (1 rear, 1 side). Viewing Angle 178 degree. Make Panasonic/ Sony/ Samsung | BI01010001010000000000000515BI0100001759 | 1 | Nos |
| 649 | 649 | Supply, Installation, Testing and comissioning of Layer -2 Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000 gbps base Tx PoE port, 1no. dual personality Gbe Port for copper/fiber uplink, 3.7 Gbps switching capacity, 2.7 MPPS forwarding rate, maximum power consumption 85 watt. (For All Floors) Make: Cisco/Juniper/D-Link | BI01010001010000000000000515BI0100001760 | 5 | Nos |
| 650 | 650 | Supply, Installation, Testing and comissioning of Layer -2 Switch with Power on Ethernet (PoE) enabled, with 24 nos. 10/100/1000 GBPS base Tx PoE port, 1 no. dual personality Gbe Port for copper/fiber uplink, 3.7 Gbps switching capacity, 2.7 MPPS forwarding rate, maximum power consumption 135 watt. (For All Floors) Make: Cisco/Juniper/D-Link | BI01010001010000000000000515BI0100001761 | 1 | Nos |
| 651 | 651 | Supply Installation Testing & Commissioning of 6U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. UL certified Make: Comrack/Netrack /Valrack | BI01010001010000000000000515BI0100001762 | 2 | Nos |
| 652 | 652 | Supply Installation Testing & Commissioning of 17U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. UL certified Make: Comrack/Netrack/ Valrack | BI01010001010000000000000515BI0100001763 | 1 | Nos |
| 653 | 653 | Supply Installation Testing & Commissioning of CAT 6 UTP Cable. Make: Make Dlink/Siemen/Polycab | BI01010001010000000000000515BI0100001764 | 1500 | P/M |
| 654 | 654 | Supply Installation testing Commissioning of PVC Conduit Pipe, 25mm medium, ISI Mark with complete accessories. Make: as per brand list of HPHC | BI01010001010000000000000515BI0100001765 | 1000 | P/M |
| 655 | 655 | TOTAL CCTV PART (F) | BI01010001010000000000000515BI0100001766 | ||
| 656 | 656 | RAIN WATER HARVESTING SYSTEM | BI01010001010000000000000515BI0100001767 | ||
| 657 | 657 | HSR PART\nExcavation for pipelines running under pressure In trenches and pits, in streets & lanes including Trimming and dressing sides, leveling of beds of trenches to correct\nGrade, cutting joint holes, cutting rrees and bushes etc., refilling Consolidation and watering of refill, in 15 cm layers and Restoration of unmetalled or unpaved surfcae \nTo its original conditon, including the cost of dewatering Of rain water, diversion of traffic, nigh signals, fixing caution boards, Crossing over trenches for access to the houses, washing, financing, etc.,And disposal of surplus soil outside and inside theTown involving lead upto one km in ordinary soil. (HSR 6.9 + CP 370%)\na) without timbering and shoring upto 1.5 metres depth | BI01010001010000000000000515BI0100001768 | 15.75 | %Cum |
| 658 | 658 | b)with timbering and shoring:\nii) Exceeding 1.5 metres dept, but upto 2.25 metres depth. | BI01010001010000000000000515BI0100001769 | 7.88 | %Cum |
| 659 | 659 | iii) Exceeding 2.25 metres depth, but upto 3.00 metres depth. | BI01010001010000000000000515BI0100001770 | 7.88 | %Cum |
| 660 | 660 | vi) Exceeding 3 metres depth, but upto 4.5 metres depth | BI01010001010000000000000515BI0100001771 | 10.5 | %Cum |
| 661 | 661 | Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres. (HSR 6.6 + CP 425%) | BI01010001010000000000000515BI0100001772 | 15.66 | %Cum |
| 662 | 662 | Earth filling under floors with surplus soil, excavated from foundation and taken only from outside the building plinth, in 15 cm layers, including ramming watering and consolidating lead upto 30 metres. (HSR 6.13 + CP @ 370%) | BI01010001010000000000000515BI0100001773 | 40 | %Cum |
| 663 | 663 | Cement concrete 1 : 4 : 8 with stone aggregate 20 mm Nominal size in foundation and plinth. (HSR 10.38 + CP @ 450%) | BI01010001010000000000000515BI0100001774 | 6.92 | Cum |
| 664 | 664 | Cement concrete 1; 2 ; 4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41 + CP @ 450%) | BI01010001010000000000000515BI0100001775 | 2 | Cum |
| 665 | 665 | First class brick work laid in cement, stone dust (from crusher) mortar 1:5 in foundation and plinth. (HSR 11.23 + CP @600%) | BI01010001010000000000000515BI0100001776 | 12.32 | Cum |
| 666 | 666 | 12 mm thick cement plaster 1:3 with Cement rendering on plaster 1 mm thick. (HSR 15.4 + 15.75) | BI01010001010000000000000515BI0100001777 | 3 | Sqm |
| 667 | 667 | TOTAL (HSR PART) | BI01010001010000000000000515BI0100001778 | ||
| 668 | 668 | DSR PART\nBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. (DSR 23.1.1.1) All types of soil \n300 mm dia | BI01010001010000000000000515BI0100001779 | 30 | Rmt |
| 669 | 669 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.3.2)\nb) 150 mm nominal size dia | BI01010001010000000000000515BI0100001780 | 18 | Rmt |
| 670 | 670 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.4.2)\n150 mm nominal size dia | BI01010001010000000000000515BI0100001781 | 12 | Rmt |
| 671 | 671 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge. (DSR 23.8) | BI01010001010000000000000515BI0100001782 | 3.18 | Cum |
| 672 | 672 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR 23.5) | BI01010001010000000000000515BI0100001783 | 14.53 | Cum |
| 673 | 673 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge. (DSR 23.7) | BI01010001010000000000000515BI0100001784 | 16.57 | Cum |
| 674 | 674 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR 23.12) | BI01010001010000000000000515BI0100001785 | 5 | Hour |
| 675 | 675 | TOTAL (DSR PART) | BI01010001010000000000000515BI0100001786 | ||
| 676 | 676 | NS PART\nProviding and fixing of non woven Geotextile having thickness of 400 gsm, having minimun tear Strength of 250 ASTM D4533, width wise at least 215 ASTM D4533 having puncture strength of 1550 plus as per ASTM D6241 Having elongation at Break % of 57 plus as per ASTM D 4595 in Two layers, made out of long fibers to hold the modules including cutting, sizing, heat welding and needle punched for high porosity and proper percolation. Complete as per entire satisfaction of engineer-in-charge \nFormula : 2X (2(LxB)+2(BxH)+2(HxL)) Layers+25% overlap (ns) (NS) | BI01010001010000000000000515BI0100001787 | 70 | Sqm |
| 677 | 677 | Providing & Fixing of Co-polymer based rainwater harvesting structure including supply of crosswave of size 494 mm x 494 mm x220mm with minimum void ratio of 94.7% having a weight of 1.8 kg and spacers having size of 988 mm x 240 mm x 25 mm having a weight of 0.8 kg of approved make and arranging the same in as directed by the engineer-in-charge and in complete accordance to the design, drawings as per entire satisfaction of Engineer -in-charge (NS) | BI01010001010000000000000515BI0100001788 | 10 | Cum |
| 678 | 678 | Providing and fixing of CGWB/GRIHA approved Pure Rain Filters with extensions as required desilting suspended solid catcher made out of FRP and strainers including bucket of SS 304 grade with long fiber foam size around 600mm dia, filtration capacity 40 kiloliters per hour with porosity of 600 microns filter complete in accordance to the desgin , drawing and specification complete as per entire satisfaction of Engineer-in-Charge. Size of FIlter 780 mm Dia, 800 mm height (NS) | BI01010001010000000000000515BI0100001789 | 1 | Each |
| 679 | 679 | Supplying and fixing of 300 mm supreme UPVC Pipe 315mm O/D conforming toI.S 4985-81 Dated-12/12/2013,I.S marked having 6 KG per centimeter square Pressure i.e. excavation, refilling for providing proper loop from catch pit to filter /filter to cross wave as per entire satisfaction of Engineer in charge. (from chamber to Filter to tank) (NS) | BI01010001010000000000000515BI0100001790 | 3 | Rmt |
| 680 | 680 | Providing and Fixing of Medium Duty SFRC cover of required size with perforated slots over gully chamber. All as per requirments and direction of Engineer-in-charge. (NS) | BI01010001010000000000000515BI0100001791 | 1 | Each |
| 681 | 681 | TOTAL (NS PART) | BI01010001010000000000000515BI0100001792 | ||
| 682 | 682 | Note:- Only the bidders who have executed similar works for Auditorium buildings including HVAC, acoustics, Audio Video conference system, stage lighting & fire fighting | BI01010001010000000000000515BI0100001793 |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy