}

Construction, Trenching Work, Trenching, Bikaner-Rajasthan

Government Departments has published Construction, Trenching Work, Trenching. Submission Date for this Tender is 11-03-2016. Trenching Tenders in Bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

9162539
Construction, Trenching Work, Trenching
Open Tender
Indian
Rajasthan
Bikaner
11-03-2016

Tender Details

1 Labour Charges For Ac / Pvc / Upvc / Ci / Gi Lekage / Burst Pipe With Care By Excavating Trenches In All Type Of Soil Including Road Cutting ( Wbm / Bitumen / Cc ) To Required Length & Depth. Taking Out The Burst Pipe By Cutting Of Pipe At Both Ends And Or Untighting And Removing Of Ci Joints / Coupler Etc. As Per Site Condition, Dewatering If Required, Fixing Of Fresh Pipe Of Length More One Mtr. And Upto 2.0 Mtr, With Joints And Earth Filling Trenches With Earth Upto Ground Level And Testing The System At Required Pressure Complete Job ( Material To Be Supplied By Department ) For Pipe Line Of Size :- 1.1 50Mm / 65Mm Ac / 75Mm Pvc 1.2 80Mm Ac / 90Mm Pvc 1.3 100Mm Ac / 110Mmpvc 1.4 125Mm Ac / 140Mm Pvc 1.5 150Mm Ac / 160Mm Pvc 1.6 200Mm Ac / 220Mm Pvc 1.7 250Mm Ac / 280Mm Pvc 1.8 300Mm Ac / 315Mm Pvc 2 Labour Charges For Removal Of Chocking In Ac / Pvc / Upvc / Ci / Gi Pipe Line With Care By Excavating Trenches In All Type Of Soil Including Road Cutting ( Wbm / Bitumen / Cc ) To Required Length & Depth, Cutting Of Pipe And Or Untighting And Removing Of Ci Joints / Coupler Dewatering Etc. As Per Site Condition Observing Pipeline By Inserting Rubber / Mdpe Pipe / Iron Stick For Location Choked Point After Removal Of Chocking Pollution Source Washing The Pipe Line Fixing Of Old Pipe After Making Proper Cutting Or Fixing Of Fresh Pipe Of Lenth Less Than One Meter With Joints Complete Job With Testing The System At Required Pressure. For Each Pit ( Material To Be Supplied By The Department ) For Size Of Pipe. 2.1 50Mm / 65Mm Ac / 75Mm Pvc 2.2 80Mm Ac / 90Mm Pvc 2.3 100Mm Ac / 110Mmpvc 2.4 125Mm Ac / 140Mm Pvc 2.5 150Mm Ac / 160Mm Pvc 2.6 200Mm Ac / 225Mm Pvc 2.7 250Mm Ac / 280Mm Pvc 2.8 300Mm Ac / 315Mm Pvc 3 Labour Charges For Leakage Removal By Using Ms Champ And Woden Dot Of Ac / Pvc / Upvc / Ci / Gi Pipe Line With Care By Excavating Trenches In All Type Of Soil Including Road Cutting ( Bwm / Bitumen / Cc ) To Required Length &Depth If Leakage Is Found In Old Disconnected And Or Leakages Service Connection And Hole In Pipe Fixing Ms Leakage Clamps After Removing Old Connection Clamp And Gi Pipe Fitting From That Working Point As Per Site Condition And Or Inserting Lead Wood In To Air Conditioner Coupling / Ci Jont As The Case Found As Site Of Leakage Including Dewatering If Required And Refilling Trenches With Earth Upto Ground Level Complete Job With Testing The System At Required Pressure ( Material To Be Supplied By Department. ) For Pipe Line Of Size 3.1. 50Mm / 65Mm Ac / 75Mm Pvc 3.2 80Mm Ac / 90Mm Pvc 3.3 100Mm Ac / 110Mmpvc 3.4 125Mm Ac / 140Mm Pvc 3.5 150Mm Ac / 160Mm Pvc 3.6 200Mm Ac / 220Mm Pvc 3.7 250Mm Ac / 280Mm Pvc 3.8 300Mm Ac / 315Mm Pvc Labour Charges For Interconnection Work Of Distribution System Of Ac / Pvc / Upvc / Ci / Gi Pipe Line With Care By Excavating Trenches In All Type Of Soil Including Road Cutting ( Wbm / Bitumen / Cc ) To Required Lenth & Depth Cutting Of Pipes For Three Sides Making Suitable Position For Fixing Ms Clamp By Fixing Joints And Pipes Of Pipe Line As Per Site Condition Requirement Providing And Fixing Pvc Circlar Oriifice As Per Instuction Of Engineer In Incarge Of Site And Then After Fixing Ms Clamp With Joints Dewatering If Required And Refilling Trenches With Earth Up To Ground Level Complete Job With Testing The System At Required Pressure ( Inch Version Shall Be Valid For Pvc Pipe Line Size ) . ( Material To Be Supplied By Department ) . With Ms Clamp Of Size 4.1 80 X 80 X 80 Mm 4.2 100 X 100 X 100 Or Less Than 100Mm 4.3 125 X125 X 125 Or Less Than 125Mm 4.4 150 X150 X 150 Or Less Than 150Mm 4.5 200 X 200 X 200 Or Less Than 200Mm 4.6 250 X 250 X 250 Or Less Than 250Mm 4.7 300 X 300 X 300 Or Less Than 300Mm Labour Charges For Interconnection Work Of Distribution System Of Ac / Pvc / Upvc / Ci / Gi Pipe Line With Care By Excavating Trenches In All Type Of Soil Including Road Cutting ( Wbm / Bitumen / C..C ) To Required Lenth & Depth Cutting Of Pipes For Three Sides Making Suitable Position For Interconnection Tee By Fixing Joints And Pipes Of Pipe Line As Per Site Condition Requirement Prviding And Fixing Pvc Circlar Roifice As Per Instuction Of Engineer In Incarge Of Site And Then After Fixing Ms Tee With Joints Dewatering If Required And Refilling Trenches With Earth Up To Ground Level Complete Job With Testing The System At Required Pressure ( Inch Version Shall Be Valid For Pvc Pipe Line Size ) . ( Material To Be Supplied By Department ) . With Ms / Ci Tee Of Size 5.1 80 X 80 X 80 Mm 5.2 100 X 100 X 100 Or Less Than 100Mm 5.3 125 X125 X 125 Or Less Than 125Mm 5.4 150 X150 X 150 Or Less Than 150Mm 5.5 200 X 200 X 200 Or Less Than 200Mm 5.6 250 X 250 X 250 Or Less Than 250Mm 5.7 300 X 300 X 300 Or Less Than 300Mm Labour Charges For Replacing Sluice Valve Or Fixing New Sluice Valve In Existing Distribution System Including Excavating Trenches In All Type Of Soil Including Road Cutting ( Wbm / Bitumen / C.C. ) To Required Length & Depth Cutting Of Pipe Line If Length Of New Sluice Valve Is Not Match With Old Sluice Valve, Dewatering And Fixing As Per Direction Of Engineer In Charge ( Material To Be Supplied By Department ) . For Replacing Sluice Valve After Removal Of Existing Sluice Valve & Fixing New Sluice Valve In Existing System Of Size 6.1.1 80Mm 6.1.2 100Mm 6.1.3 125Mm 6.1.4 150Mm 6.1.5 200Mm 6.1.6 250Mm 6.1.7 300Mm 6.2 For Fixing New Sluice Valve In Existing System Where Sluice Valve Exist In Sluice Valve Chamber Of Size. 6.2.1 80Mm 6.2.2 100Mm 6.2.3 125Mm 6.2.4 150Mm 6.2.5 200Mm 6.2.6 250Mm 6.2.7 300Mm 7 Labour Charges For Opening Sluice Valve Head For Taking Out Faulty Parts From Inside The Valve In Existing Distribution Sytem Including Excavating Trenches In All Type Of Soil Including Road Cutting ( Wbm / Bitumen / C.C. ) To Required Length And Depth Dewatering And Fixing Head Again Opening The Head Of Valve For Inserting The Repaired / New Parts Of Valve And Closing The Head Of Valve For Repairing Of Sluice Valve As Per Direction Of Engineer For Size. ( Work Of Head Opening And Closing For Twice Time ) . Material To Be Supplied By Department 7.1 80Mm 7.2 100Mm 7.3 125Mm 7.4 150Mm 7.5 200Mm 7.6 250Mm 7.7 300Mm.

Key Value

Document Fees
INR 500 /-
EMD
INR 19800.0 /-
Tender Value
INR 9.90 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail