| 1 | wiring point for lightwith 1.5sq. Mm FRLSH PVC insulated multistrand copper conductor cabelin PVC conduit concealed in wall complete with 1.5 sq -mm FRLSH PVC multistrand single core copper conductor as earth wire drawn inside the condut with GP box Modular type switch and celling rose / Batten holder complete in all respect as directed in ENC including matching colour wash complete in all respect |
| 2 | wiring point for Street lightwith 1.5sq. Mm FRLSH PVC insulated multistrand copper conductor cabelin PVC conduit concealed in wall complete with 1.5 sq -mm FRLSH PVC multistrand single core copper conductor as earth wire drawn inside the condut with GP box Modular type switch and celling rose / Batten holder complete in all respect as directed in ENC including matching colour wash complete in all respect |
| 3 | wiring point for fan/fresh air fan with 1.5sq. Mm FRLSH PVC insulated multistrand copper conductor cabelin PVC conduit concealed in wall complete with 1.5 sq -mm FRLSH PVC multistrand single core copper conductor as earth wire drawn inside the condut with GP box Modular type switch and celling rosecomplete in all respect as directed in ENC including matching colour wash complete in all respect |
| 4 | wiring point for Exhaust fanwith 1.5sq. Mm FRLSH PVC insulated multistrand copper conductor cabelin PVC conduit concealed in wall complete with 1.5 sq -mm FRLSH PVC multistrand single core copper conductor as earth wire drawn inside the condut with GP box Modular type switch and celling rose / Batten holder complete in all respect as directed in ENC including matching colour wash complete in all respect |
| 5 | wiring point for Call bell with 1.5sq. Mm FRLSH PVC insulated multistrand copper conductor cabelin PVC conduit concealed in wall complete with 1.5 sq -mm FRLSH PVC multistrand single core copper conductor as earth wire drawn inside the condut with GP box Modular type bell push switch and two pin socket complete in all respect as directed in ENC including matching colour wash complete in all respect |
| 6 | Supply and fixing 3 pin 5/6A moduler socket outlet and 5/6 Amp switch on the existing GI Box and modular plate surface or recess including providing and fixing ofModular switch, socket with connections etc. as required. Complete in all respect. |
| 7 | Supply and fixing suitable size GI Box with modular plate and cover in front of surface or recess including providing and fixing of 3 pin 15/16A moduler socket outlet and 15/16A a Modular switch, connections etc. as required. Complete in all respect. |
| 8 | S/F of 63ATP MCCB 10 KA @ CAT- A Complete in all respect. |
| 9 | S/F of 100A4P MCCB 30 KA @ CAT- A Complete in all respect. |
| 10 | S/F of 63A4 Pole MCB 10KA @ CAT- A Complete in all respect. |
| 11 | S/F of 63/40A DPMCB 10KA @ CAT- A Complete in all respect. |
| 12 | S/F of 6A-32A SP MCB 10 KA @ CAT- A Complete in all respect. |
| 13 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. |
| 14 | S/F OF 25x 5 mm GI strip for earthingon G.I clamps on surface complete in all respect |
| 15 | Add for extra invertor wiring point L/F/Plug with 1.5 sqmm coprative. Complete in all respect. |
| 16 | Providing and fixing 100 Amp TPN disconnector fuse switch unit on angle iron frame with ISI marked HRC fuses including drilling holes making connections etc. complete in all respect. |
| 17 | S/f of 63A 415V change over switch unit on angle iron frame including drilling holes making connections etc. complete in all respect. |
| 18 | S/f surface mounting 4 wayTPN DB with additional metal door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, ocmplete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB /Isolator) complete in all respect @ cat-A |
| 19 | S/fof 12 way single pole and neutral, sheet steel, MCB distribution board, 240 V, in surface/recess, complete with tenned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB /Isolator) complete in all respect @ cat-A |
| 20 | S/fof 4 way surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (But without MCB incomer) as required. complete in all respect @ cat-A |
| 21 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on wall surfaceas directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 Sq mm x 3.5 core |
| 22 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. Size 35 sq.mm x 3.5C |
| 23 | Extra for fixing of Luvour/Shutter. Complete in all respect. |
| 24 | Installation fo exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm Sweep. |
| 25 | Supply and fixing of call bell of approved make on polishedMDFEG/ Teak ply boardincluding making connections etc. complete in all respect. |
| 26 | S/W of submain alongwith earth wire with thewith following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. Complete in all respect.4 x 10 sq. mm + 2 x 6 sq. mm earth wire. |
| 27 | S/W of submain alongwith earth wire with thewith following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. Complete in all respect.2 x 10 sq. mm + 1 x 6 sq. mm earth wire. |
| 28 | S/W of submain alongwith earth wire with thewith following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. Complete in all respect.2 x 6 sq. mm + 1 x 6 sq. mm earth wire. |
| 29 | S/W of submain alongwith earth wire with thewith following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. Complete in all respect.2 x 4 sq. mm + 1 x 4 sq. mm earth wire. |
| 30 | S/W of submain alongwith earth wire with thewith following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. Complete in all respect.2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 31 | S/W of submain alongwith earth wire with thewith following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. Complete in all respect.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire. |
| 32 | Supply and fixing and concealing of 25 mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction ofEngineer in charge. |
| 33 | S/f of Sheet steel enclosure surface/Recess along with 25/32 A 240V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 34 | S/F of suitable size G.I. Box with modular plate and cover in fornt on surface or in recess, including providing and fixing 2 Nos. 3 Pin 5/6 A modular socket outlet and 02 No. 5/6 A modular switch, connections etc. as required. (For ligh plugs to be used in non residential buildings.) |
| 35 | Supply and fixing ofSingle LED light wall bracket 3 to 6 Watt on matching M.D.F.E.G Board base etc. complete in allrespect. CAT- AAA |
| 36 | Supply and fixing ofwater tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP65 and above Protection . complete in allrespect. CAT-AAA |
| 37 | SITC of 1200 mm sweep, BEE 5 star rated, celling fan with Brush Less Direct Current (BLDC) Motor, class of insulated : B, 3 Nos, blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max,), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc. omcplete as required. |
| 38 | S/F of exhaust fan 300mm size Heavy Duty. Complete in all respect. |
| 39 | Dismentalling of old switch board, DB, wiring etc. complete in all respect. |