Tender For Work Of Expansion Of Tourist Facility Centre Building In Vrindavan, Mathura District - Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil l(1.5m to 3.0m) 3 (3.0m to 4.5m) 4 (4.5m to 6.0m) 5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 6 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 7 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 8 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 9 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 10 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. Carriage of Earth ( upto 5 km per km) 11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 12 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 13 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 14 Centring and shuttering including strutting,propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. 15 Suspended floors, roots, landings, balcnies and access platform. 16 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 17 Columns,Pillars, Piers, Abutments, Posts and Struts 18 Stairs,(excluding landings) except spiral-staircaces. 19 Edges of slabs and breaks in floors and walls Under 20 cm wide 20 Weather shade,Chajjas, corbels etc. including edges 21 Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of deshutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roots, laning, beams and balconies (Plan area to be measured) 22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 23 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 24 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement contant of 330 kg/cum 25 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 26 Machine moulded common burnt clay FPS (non modular) bricks of class designation 12.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 27 Brick work with Machine moulded common burnt clay FPS (non modular) bricks of class designation 12.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 28 Half brick masonry withMachine moulded common burnt clay FPS (non modular) bricks of class designation 12.5in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 29 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 30 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/Ruby red Area of slab upto 0.50 sqm 31 Area of Slab over 0.50sqm 32 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. 33 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 34 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 35 Providing and fixing 12 mm toughened glass partition with neccessary fittings and Applying clear silicon on joints complete in all respect. 36 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 37 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edge 38 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square. 39 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 40 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 41 Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain)toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor ≤ 0.45, U-Value ≤ (W/sq.m-K) 5.7W /M2K, Visible light transmittance ≥ 0.30) 42 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 43 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 44 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortice lock with key cylinder fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 45 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 46 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 47 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 48 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 49 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.. 50 Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 51 Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 52 Providing and fixing approved brand and manufacture SS 304 grade Center Patch Lock wih Cylinder complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 53 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness 54 Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly, for staircase /exit pathway and refuge areas applications, consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested in latched condition as per IS 17518 (Part-1) 2022 Frame:The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS 4351. The smoke seal material shall be of EPDM tested in accordane with ASTM E-84 of minimum size 10 x 4mm. fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK/Hex headed fastner of minimum 8 mm dia size and minimum 80mm long hot dip galvanized with 8mm dia Polyamide sleeves @ 5 number at each on vertical sides and 3 number on top side. Door shutter:The double skinned double leaf partially insulated door shutters shall be consisting of minimum 50 mm thickness and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded mineral wool/ ceremic wool infill material of minimum density 96 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaves. Integral astragals to be provided for double leaf door on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935 2002 or butt hinges as per IS 12817, of minimum size 100x75x3 mm @ 5 numbers hiiges upto 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories.Accessories Hardware Accessories HardwareFire doorset assembly shall be provided with one number of single point panic push bar (cross bar) for active leaf and one number double point panic push bar (cross bar) with bottom strike of desired finish with verticle shoot bolts on top and bottom for inacitvie leaf of double leaf door as per EN 1125, one number external trim with half cylinder 42 mm long with one side key as per EN 1125, two number heavy duty door closers of size EN 3-5 with standard arm with of desired finish (suitable for 1250 mm wide door leaf) conforming to IS 3564/EN 1154, and one number surface mounted door coordinator for sequencing of closing.Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturers specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer. Single leaf partially Insulated metal fire rated doorset of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614 2021 for Staircase/Exit pathway/ Refuge area etc 55 Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly, for staircase /exit pathway and refuge areas applications, consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested in latched condition as per IS 17518 (Part-1) 2022 Frame:The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS 4351. The smoke seal material shall be of EPDM tested in accordane with ASTM E-84 of minimum size 10 x 4mm. fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK/Hex headed fastner of minimum 8 mm dia size and minimum 80mm long hot dip galvanized with 8mm dia Polyamide sleeves @ 5 number at each on vertical sides and 3 number on top side.Door shutter:The double skinned double leaf partially insulated door shutters shall be consisting of minimum 50 mm thickness and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded mineral wool/ ceremic wool infill material of minimum density 96 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaves. Integral astragals to be provided for double leaf door on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935 2002 or butt hinges as per IS 12817, of minimum size 100x75x3 mm @ 5 numbers hiiges upto 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories.Accessories HardwareAccessories HardwareFire doorset assembly shall be provided with one number of single point panic push bar (cross bar) for active leaf and one number double point panic push bar (cross bar) with bottom strike of desired finish with verticle shoot bolts on top and bottom for inacitvie leaf of double leaf door as per EN 1125, one number external trim with half cylinder 42 mm long with one side key as per EN 1125, two number heavy duty door closers of size EN 3-5 with standard arm with of desired finish (suitable for 1250 mm wide door leaf) conforming to IS 3564/EN 1154, and one number surface mounted door coordinator for sequencing of closing.Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturers specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer. Double leaf partially Insulated metal fire rated doorset of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614 2021 for Staircase/Exit pathway/ Refuge area etc 56 Providing and fixing Fire Resistance Glazed partition, tested as per EN1364-1 / IS 16945 for stability and integrity. Glazed Partition shall be tested from CBRI / Certifire / NABL Accredited Lab / any other reputed labs for a minimum rating of 120mins. & 20 Mins. Insulation. 57 Providing and fixing fire resistant door frame of section 50 x 60mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). 58 Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately). 59 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in-charge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of 37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments). 60 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. 61 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 62 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube 63 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 10 mm 64 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) 65 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece 66 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of requiredthickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover 67 Providing and fixing ball bearing for rolling shutters. 68 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backingfilled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing. 60 mm thick 69 30 mm thick 70 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 71 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases 72 Supply, fabricating, transporting, hoisting and fixing in position good quality durable Mirzapur sand stone/ any other type of sand stone in various elements for all level all height.Stone shall be free from cracks, lines, stains, white spots of efflorescence and even in shade for each elements. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with differant process ofi.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The drawings provided are vary preliminary and amount of carving will be more then what is shown on the drawings. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 73 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust)with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone 74 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 75 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick 76 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 77 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm 78 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 79 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 600x600 mm 80 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 81 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 82 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 83 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 84 Extra for pre finished nosing to treads of steps of Granite stone. 85 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 86 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mmhavingwithwaterabsorptionlessthan0.5%andconformingto IS:15622ofapprovedmakeinallcoloursandshadesinforoutdoorfloorssuchas footpath,courtyard,multimodalslocation etc.,laidon20mm thickbaseofcement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per drawings anddirection of Engineer-in-Charge. 87 Providing and laying 18 mm thick leather finish steel grey granite stone flooring in required design and patterns, in linear as well as curvilinear portions in building flooring, footpath etc. all complete as per the architectural drawings with over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 88 12mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) 89 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand) 90 6 mm cement plaster to ceiling of mix : 1:3(1 cement: 3 coarse sand) 91 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 92 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 93 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 94 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 95 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or more coats on new work 96 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 97 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 98 Painting with synthetic enamel paint of approved brand and manufacture to give an evenshade : Two or more coats on new work 99 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) 100 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall bepre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 101 Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling sectionand perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture’s specification and also including the cost of making openingfor light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. 102 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron) 103 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminum (minimum thickness of powder coating 50 micron) 104 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 10 mm depth and 10 mm width 105 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm 106 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 107 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 108 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 109 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 110 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 111 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 112 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 113 Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid witha mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. 114 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levellingto required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine 115 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade ‘A’ sealing compound conforming to IS: 1834. 116 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge 60mm thick cement concrete paver block of M-35 grade with approved colour, design &pattern. 117 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 118 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete New work (Two or more coats) 119 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 120 Providing and fixing factory made precast RCC saucer drain having concrete of strength not less than M-30, of size 300 x 450 x 100 / 75 mm aligned with line of kerbstone including all charges complete under the direction of direction of Engineerin- charge. 121 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 122 Supplying and stacking at site dump manure screening by 4.75 mm sievefrom approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : 123 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep 124 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 125 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 126 Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 127 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPEbag as per direction of the officer-in-charge. 128 Providing and displaying of Dracaena margineta plant, having ht. 30 cm to 45 cm with colorful leaves, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 129 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e lawn trees,shrubs, hedge, flower beds,foliages,creepers etc including hoeing, weeding pruning replacement of plants, gap filling, watering,mowing of lawn,grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecting sites,pesticide and fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office in charge. (cost of good earth,menure, fertilizers, insecticide , pesticide,lawn mover and brush cutter with fuel will be provided by the department and other T/P material/articles shall be provided by the contractor. Open spaces (1Mali for 3.00 Acre).FOR 3 YEAR 130 Providing, fixing, testing & commissioning of white Vitreouschina wall hung European type water closet with P trap, with lid , seat cover with CP bolts, nuts, concealed cistern with Face plate ,CP brass hinges and rubber buffers , WC pan connector / flush pipe with clamp and adapter rubber joint & necessary fittings screws and washers complete including cutting and making good the walls and floors where required.Wall Hung WC with seat cover Kohlar Model- K-26998IN-0 + WC Connector Kohlar Model - K-1046327-S + Concealed Flushing Cistern Kohlar Model- K-26352IN-M-NA+Face Plate for Cistern Kohlar Model-K-20189IN-P-CP, WC Chair Bracket Kohler Model-K-1225108-0 or Equivalent. 131 Providing and fixing white vitreous china wash basin with special fabricated brackets painted white, faucets as required, 32 mm C.P. brass waste.32 mm C.P. brass bottle trap & pipe to wall with rubber adopter for waste connection and C.P. brass wall flange complete in all respects including cutting and making good the walls where required.Under Counter Wash basin KohlarModel No.: K-2215IN-2-0 , 32 mm CP brass waste Kohlar Model No. K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Kohlar Model. No.K-75823IN-CP or approved equivalent. 132 Providing and fixing 15mm C.P brass Pillar Foucet Kohlar Model. No. K-75377IN-4-CP or approved equivalent for Wash Basin Including cutting and making good the walls wherever required. 133 Providing and fixing 15mm C.P. copper connecting pipe 450mm long with C.P. brass nuts, washers complete in all respects.(Jaquar Cat No. ALD 803AB or approved equivalent) 134 Providing & Fixing vitreous china urinal basin Kohlar Model No. K-16321IN-SS-0 or approved equivalentwith C.I. Hangers,comprising of electronic & electrical items includinginfrared photo cells eyes, electronically operated solenoid valve, step down equipment, electric operated,concealedpiping etc. & any otheritem requiredto provide satisfactory functioning, 32 mm CP brass waste Kohlar Model No. K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Kohlar Model. No.K-75823IN-CP or approved equivalent complete including cutting and making good thewalls and floors where required. 135 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm, bowl depth 200mm. 136 Providing and fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. waste fittings complete Semi rigid pipe 40 mm dia. 137 Providing and fixing C.P. brass 15 mm nominal bore two way bib cock Kohlar Model-K-20075IN-4-CP or Equivalent. 138 Providing and fixing C.P. brass 15 mm nominal bore one way bib cock Kohlar Model-K-20073IN-4-CP or Equivalent. 139 Providing and fixing C.P. brass 15mm nominal bore angle valve Kohlar Model- K-80154IN-4-CP or Equivalentfor basin mixer and geyser points. 140 Providing and fixing C.P. cast brass twin coat hooks fixed to PVC rawl plug with SS screws Kohlar model. No. K-25073IN-CP or approved equivalent. 141 Providing and fixing health faucet with 1 m long flexible tube and wall hook including all fittings Kohlar model No.K-12925IN-CP or approved equivalent. 142 Providing and fixing of C.P. brass 600 mm size towel railKohlar Model.No. K-25065IN-CP or equivalent fixed with C.P. brass screws complete in all respects. 143 Providing and fixing of C.P. brass Soap Dish MakeKohlar Model- K-5634IN-CP or equivalent) fixed with C.P. brass screws complete in all respects. 144 Providing and fixing C.P brass toilet paper holderKohlar Model. No. K-5633IN-CP or approved equivalent,Including cutting and making good the walls wherever required. 145 Providing and fixing liquid dispenser including all fittings complete.(Kohlar Model-K-10712D-CP) 146 Providing and fixing Grab Bar Kohlar Model No. K-10701D-CP or approved equivalent,Including cutting and making good the walls wherever required 147 Providing and fixing Hand Rail Euronics model. No. EGR S02 or approved equivalent,Including cutting and making good the walls wherever required 148 Providing and fixing fully automatic Hand dryer Euronics Model-EH 26 NW or equvalant ,including all fittings complete in all respect. 149 Providing and fixing Air Purifier Euronics Model-EA 24 or equvalant ,including all fittings complete in all respect. 150 Providing and fixing 150 litre/ hr. cooling and storage capacity,fully stainless steel electric storage type water cooler ( Blue Star model No. SDLX 15150 or equvalant) with inlet hose connection inbuilt float valve. 2 Nos. outlet foucet, drain tray with waste and pipe up to fllor trap heavy compressor and wire up to socket, 3 pin plug etc complete in all respect. 151 Supplying, installation, testing and commissioning of skid mounted fully automatic Reverse Osmosis System of output capacity 50 litres / hour designed at a minimum Flux at inlet complete as required. 152 Providing and Fixing of C.P. Brass Shower set comprising of : One No. CP brass diverter mixer. Make Kohlar Model No. K-P16316IN-4FP-CP + K-882IN-CP or approved equivalent. One No. CP brass OH shower head & Shower Arm Make Kohlar Model No.K-23657IN-CP or approved equivalent. One No. CP brass Bath Spout Make Kohlar Model No.K-99060IN-CP or approved equivalent. Including cutting and makinggood the walls wherever required. Shower set as described above. 153 Providing and fixing 15mm C.P brass Sink Mixer Jaquar Model. No. CON-309KN or approved equivalent.) for kitchen sink with swinging spout complete. Including cutting and making good the walls wherever required . 154 Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). Capacity 25 Litres Model 25 GV 155 Reinforced cement concrete work in well-steining,excluding the cost of centering,shuttering,finishing and reinforcement with in 1:1.5:3 ( 1cement : 1.5 Coarse sand(zone111) : 3 graded stone aggregate 20 mm nominal size ) 156 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 157 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 158 Providing and fixing soil, waste and vent pipes. 100 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 159 75 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 160 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete. 100 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 161 Providing and fixing plain bend of required degree.100 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 162 75 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 163 Providing and fixing double equal plain junction of required degree. 100x100x100x100 mm Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 164 Providing and fixing single equal plain junction of required degree. 100x100x100 mmHubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 165 75 x 75 x 75 mmHubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 166 Providing and fixing terminal guard. 100 mm Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 167 Providing and fixing shieled coupling for Hubless centrifugally cast iron pipes. 100 mm dia. SS 304 grade coupling with EPDM rubber gasket. 168 Providing and fixing trap of self cleansing design with screwed down or hinged with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outletHubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905 169 Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work.100 mm diameter pipe 170 75 mm diameter pipe 171 Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 32 mm dia. nominal bore 172 50 mm dia. nominal bore 173 Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 32 mm dia. nominal bore 174 50 mm dia. nominal bore 175 Providing and fixinguPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all+C92+C90 176 110 mm OD 177 Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical soil, waste, vent and rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. For 75 mm dia Pipe 178 For 100 mm dia Pipe 179 For 160 mm OD Pipe 180 Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint. 100 mm dia 181 Providing and fixing in position 100x50 mm dia GI reducing elbow including fix to floor with cement mortar. 182 Providing and fixing in position 125x125 mm stainless steel grating for floor trap/floor drain including fix to floor with cement mortar. 183 Providing and fixing 100 mm dia GI inlet fitting/ Extension Piece with 2 or 3 inletsof 32 to 50 mm dia, fixed to CI trap with lead joint and set in cement concrete as per drawing complete. 184 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes. 185 25 mm nominal outer dia .Pipes. 186 32 mm nominal outer dia .Pipes. 187 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore 188 25 mm dia nominal bore 189 32 mm dia nominal bore 190 40 mm dia nominal bore 191 Providing, laying and Jointing G.I. B class pipes and fittings conforming to IS: 1239 (Medium class) with fittings, union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1:2 (1cement: 2 coarsesand)complete in all respects for internal works including pipe supports with galvanised GI. slotted angle iron, GI clamps, spacers as required and making good wherever required. (For Vertical in Shafts & Terrace only)Internal Work - Exposed on Wall 65 mm dia. nominal bore 192 80 mm dia. nominal bore 193 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 20 mm dia nominal bore 194 25 mm dia nominal bore 195 32 mm dia nominal bore 196 40 mm dia nominal bore 197 65 mm dia. nominal bore 198 80 mm dia. nominal bore 199 Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. 20 mm nominal bore 200 25 mm nominal bore 201 32 mm nominal bore 202 40 mm nominal bore 203 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming to IS 13095 of following sizes as required : 65 mm dia 204 80 mm dia 205 Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 20 mm dia Pipe 206 Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia. 207 Providing and fixing of Single phase electrical actuator operated wafer type rubber lined butterfly valve with by pass arrangement as per drawing attached including level controller, 3 nos. normal butter fly valves,necessary control and Power cables ( Maximum 10 M. Length of each type) and control panel installed on OH tank filling line near the tanks complete in all respects. 32 mm dia. 208 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia nominal dia. Pipe 209 32 mm dia nominal dia. Pipe 210 40 mm dia nominal dia. Pipe 211 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 212 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 25 mm diameter Pipe 213 32 mm diameter Pipe 214 40 mm diameter pipe 215 Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. 32 mm nominal bore 216 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 217 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 218 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 219 Extra for every additional lift of 1.5m or part thereof in: All kinds of soil (Manhole) 220 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : For Bed Concrete of Sewer Lines. 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 221 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150x100 mm size P type With common burnt clay (non modular) bricks of class-150 222 Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. 150 mm dia. 223 200 mm dia. 224 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 225 Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 226 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 227 Extra depth for circular type manhole 0.91m internal dia (at bottom) with beyond 0.91m to 1.67m. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 228 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 229 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 LPM at 35 m Head 230 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia. 231 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia 232 80 mm dia 233 100 mm dia 234 Providing, laying, testing & commissioning of B class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia. 235 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel 236 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia 237 100 mm dia 238 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 100 mm dia 239 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) 240 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m 241 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable fornstantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) 242 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe 243 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 244 Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words Fire Hydrant written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire mans axe, fire extiguishers 2 nos, including suitably mounted on a raisedmasonry platform as required. (Approx.size 0.90 m x 2.1m ) 245 Providing and fixing dial type pressure gauge with isolation cock and pipe at hydrant station. Dial diameter 100 mm caliberation, 0-15 kg 246 MCC for Fire Fighting Pumps at Terrace INCOMING: a) One 100 amp. TP +NL M.C.C.B. with rotary handle of breaking capacity 25 KA b) One-Volt Meter (0-500 V) with selector switch c) One Set indicating lamps BUS BARS OUTGOING a) 100 Amp TPN BUS BAR (Aluminium). b) One - 63 Amp.TP +NL M.C.C.B. with rotary handle of breaking capacity 35KA c) One FullyAutomatic D.O.L Starter suitable for Jockey Pump Motor 15 KW with over loadrelay,timer push buttons and Auto/Manual selector switch d) One panel type Amp. meters onefor each motor with ASS. CTS etc. e) One sets of On/Off - neon indicating lamp.i) All interconnecting power &control wires/cables suitable size within thepanel andfrom panel to motors , pressure switches, level switches, cable Tray, pipes etc. includingbrass glands terminationwithin fire pump house and earthing as per specifications. 247 Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 4.5 Kg. 248 Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 6.0 Kg. 249 Providing and fixing fire mans axe 250 Wiring for light point/ fan point/ Exhaust fan point/ call bell point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable on surface/recess medium class PVCconduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required. Group A 251 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A 252 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 253 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 254 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 255 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 256 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 257 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed i/c cutting the wall and making good the same in case of recessed conduit as required. 20 mm 258 25 mm 259 32 mm 260 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 261 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 262 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mmX75mm) 263 4 Module (125mmX75mm) 264 8 Module (125mmX125mm) 265 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 266 Supplying, Installation, Testing and commissioning of 2ft 10W High efficient LED batten surface/wall mounted Specially designed extruded Aluminium housing with PC diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI >80, Temperature range-0 to 50DegC, Driver efficiency>85%, Power factor>0.9, CCT - 6500K, THD<20%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC andSafety Extra Low Voltage Safe level<60V DC as per IEC standard.Luminaire lumen ≥ 1000 lumens (100 lm/W) 267 Supplying, Installation, Testing and commissioning of 4ft 18/ 20 W High efficient LED batten surface/wall mounted Specially designed extruded Aluminium housing with PC diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI >80, Temperature range-0 to 50DegC, Driver efficiency>85%, Power factor>0.9, CCT - 6500K, THD<20%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC andSafety Extra Low Voltage Safe level<60V DC as per IEC standard.Luminaire lumen ≥ 2000 lumens (100 lm/W) 268 Supplying, Installation, Testing and commissioning of SMD LED, IP 40, 9/10W deep Surface/ Recessed downlighter with System efficacy of 100lm/W and system lumen output 900 lumen, operating in an ambient temperatire of 0⁰C to 45⁰C at 50Hz frequency. Luminaire shall have aluminium pressure die cast housing in white with high transmittivity diffuser for uniform illumination and reduced glare UGR <19. EMC/PCT package of wattage of 0.5-1 W LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. The LED shall comply with L70 life of 50000 burning hours tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80, with MacAdam CCT binning <3 mounted on 1.6mm MCPCB/FR4 with 35 micron cu layer. LEDDriver shall be external, Isolated type,Constant Current topology driver with proper heat sink for heat dissipation suitable to operate at nominal rated voltage of240V with1 kV internal surge protection, Power factor of minimum 0.95, driver efficacy of minimum 85%, and total harmonic distortion (THD) of less than or equal to 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance toIndian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 269 Supplying, Installation, Testing and commissioning of SMD LED, IP 40, 18/ 20 W deep Surface/Recessed downlighter with System efficacy of 100lm/W and system lumen output 1800 lumen, operating in an ambient temperatire of 0⁰C to 45⁰C at 50Hz frequency. Luminaire shall have aluminium pressure die cast housing in white with high transmittivity diffuser for uniform illumination and reduced glare UGR <19. EMC/PCT package of wattage of 0.5-1 W LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. The LED shall comply with L70 life of 50000 burning hours tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80, with MacAdam CCT binning <3 mounted on 1.6mm MCPCB/FR4 with 35 micron cu layer. LEDDriver shall be external, Isolated type,Constant Current topology driver with proper heat sink for heat dissipation suitable to operate at nominal rated voltage of240V with1 kV internal surge protection, Power factor of minimum 0.95, driver efficacy of minimum 85%, and total harmonic distortion (THD) of less than or equal to 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance toIndian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 270 Supplying, Installation, Testing and commissioning of40W, High efficient 600mm dia dome shaped made of aluminium white colour coated outside finish. LEDs provided with high efficient non yellowing PMMA diffuser provides soft light.CRI>80, IP20, Ambient temp-0 to 45 Deg C, CCT - 4000K, 50,000 hrs @ L70 life.Driver efficiency>85%, THD<10%, Powerfactor>0.90, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 2960 lm. (80 lm/W). 271 Supplying, Installation, Testing and commissioning ofSurface/ Wall mounted SMD LED Bulkhead luminaire of 10W LED fixture with System efficacy of 100 lm/W and 1000 system lumens, operating in ambient temperature of 0⁰C to 45⁰C at 50Hz frequency . Luminaire shall be made up of pressure die cast aluminum housing powder coated in dark gray with polycarbonate high transmissivity opal diffuser, ensuring uniform illumination and excellent heat dissipation. LEDs used in the productcomplies with IEC 62471 for Photo-biological safety. Luminaire is with high quality silicon gasket of IP65 and IK10 protection . EMC/PCT package of wattage of 1-3 W LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. The LED shall comply with L70 life of 50000 burning hours tested at maximum current .The LEDs used shall be with CCT of 5700 K and CRI of minimum 80,with MacAdam CCT binning < 7 mounted on 1 mm MCPCB with 35 micron cu layer. LED Driver shall be of Integrated type prewired in product housing,Isolated, Constant Current with range 140-280V AC with internal surge protection of 2.5kV. Driver of Efficiency > 80%, Power factor of minimum 0.95 and total harmonic distortion (THD) of less than or equal to 10% shall be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. 272 Supply, Installation, Testing and Commissioning of 400 mm sweep high flow 16 wall mounted fancomplete with double ball bearing, motor, blades, capacitor etcsuitable for single phase 230 volts, 50 Hz., AC supply,complete as required. 273 Supply, Installation, Testing and Commissioning of300 MM Sweep Exhaust fanCapacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted bycontractor.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersof products/ work. 274 Supplying, installation, testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required 275 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)8 way , Double door 276 Supplying and fixing following way, Horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 4 way (4 + 12), Double door 277 6 way (4 + 18), Double door 278 8 way (4+24), Double door 279 12 way (4+36) Double door 280 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. Single Pole 281 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A 282 40 A 283 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps 284 40 amps 285 63 amps 286 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 287 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 288 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 289 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring washer excavation and re-filling etc. as required. 290 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required 291 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 292 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 293 Supplying of following sizes PVC insulated PVC sheathed XLPE aluminium conductor armoured LT cable of 1100 V as per IS 1554(Part I) and having ISI marking etc. as required3.5 X 70 sq. mm 294 3.5 X 95 sq. mm 295 3.5 X 120 sq. mm 296 3.5 X 150 sq. mm 297 3.5 X 240 sq. mm 298 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5 X 70 sq.mm 299 3.5 X 95 sq.mm 300 3.5 X 120 sq. mm 301 3.5 X 150 sq.mm 302 3.5 X 240 sq. mm 303 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and up to 95 sq. mm 304 Above 95 sq. mm and up to 185 sq. mm 305 Above 185 sq. mm and up to 400 sq. mm 306 Supply, installation, testing and commissioning of following outdoor type with canopy,IP-54 protected M.V. cubicle type totally enclosed, free standing type, dust, damp and vermin proof, MV Panel, busbars, M.V. danger notice plate, interconnections with suitable capacity aluminium leads/solid aluminium strips/rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing switchgears complete as required. INCOMER: 315 Amps,415 volts, TP+NL, 25 KA Moulded Case Circuit Breaker with thermal magnetic release having variable current settings . R,Y&B phaseindicating lamp (LED type) with 2A control SP MCB ,ON, OFF , TRIP for MCCB Extended rotary operating mechanism with door interlocking with defeat feature and padlock facility. MCCB should have spreader links & phase barriers. 1 Set of timer switch & 100A TP contactor with nuetral link (for street lights control) . BUSBARS: 400 Amp TPN Aluminium busbars OUTGOING: 10 Nos. 63 Amp 415 volts, FP MCCB 5 Nos. 40 Amp 415 volts, FP MCCB Feeder Pillar asmentionabove 307 Meter Board Panel for Retail Area Supplying, Testing and commissioning of wall mounted cubicaltype compartmentaliseddust, damp & vermin proof Metering Panel fabricated out ofsuitable sized angle iron and flats and covered with 2mm thick cold rolled CRCA sheet painting etc. completewith Al.bus bars, interconnection with solid/strandedcopper conductor wires copper strips neutral links, etc.and mounted with with 1 No 0-500V, Voltmeter, selector switch, 1 set (3 Nos) of phase indicating lamps, ammeter withCTsetc. as required. The Panel shall have IP-42 rating .The Panel will also include fabrication of dual energy meter boxwithspace provision of single or three phase Prepaid dual source type electronic energyMeter as per Incoming/outgoingrequirement or as per SLD with all necessary power wiring for dual metering with MS support for meter fixing , windows for meter reading inculding supply and fixing of MCBs, main frame fabricated out of 2mm in cubical formation. Incoming: 1 No. of 160 Amp 4PMCCB of 25 kA(Ics=Icu) Breaking capacity thermal based release with On Indicating Lamp with 2A SP MCB back-up. Bus Bars: 200 Amp TPN Aluminium busbars Outgoing:- All outgoing feeders shall be provided with On indicating lamp with 2 A SP MCB protection 1 Nos. 100 Amp 415 volts, FP MCCB 10 Nos. 63 Amp 415 volts, FP MCCB 4 Nos. 40 Amp 415 volts, FP MCCB Fabrication of dual energy meter boxwithspace provision of 3 phasesuitable raitings Postpaid dual source type electronicenergyMetersuitable raitings Suitable for415V in Sealable compartment- 15 NosFeeder Pillar asmentionabove 308 LIFT PANEL FOR BLOCK A - Supplying,installation,testing,commissioningofLIFTPanelsuitablefor operation on 415 V, 3 Phase, 4 wire fabricated with 2mm CRCA sheet for main structure with 7 Tank Process for powder coating in approved shade ,bottom base channel of MS section not less than 50 mmx50mmx 6 mm thick earth stud,connection,interconnectionfrommainbusbartoswitchgearwith required size flexible FRLS copper cable and control wiring with PVC insulated, cable gland i/c providing following items complete as required. INCOMER: 125 ATP16KAMCCBThermalReleaseO/L,S/CProtectionwithROHM, Spreader Link-1 No. Digital Multifunction Meter with Suitable CTs -1 Sets LED RYB Indicating Lamp with Control SP MCB (3 Nos.=1 Set) BUS BAR 150A, 4 strips Aluminium Busbar with color coded heat shrinkable sleeves. OUTGOING: 63A TP MCB C CURVE 10KA – 04 Nos. 25A TP MCB C CURVE 10KA – 01 No. 25A DP MCB C CURVE 10KA – 04 Nos. 309 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back- up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel 310 Supplying, installation, testing & commissioning ofintelligentanalog addressable photothermal detector complete with mounting base complete as required. 311 Supplying, installation, testing & commissioning of fault isolator with base complete as required. 312 Supplying,installation,testing&commissioningofintelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 313 Supplying,installation,testing&commissioningofaddressable fire control module complete as required. 314 Supplying,installation,testing&commissioningofaddressablemanualcall point complete as required. 315 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 316 Supplying, installation, testing & commissioning of addressable strobe complete as required. 317 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 318 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 319 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 320 Supply, Installation, Testing & Commissioning of the 380 W power amplifier in a 3U high housing with 70 V / 100 V and 8 ohm outputs, Dual inputs with priority switching,100 V input for slave operation on 100 V speaker line, Mains, battery back-up, With Following Features:- Output power (rms/maximum) 380 W / 720 W.-Frequency response 60 Hz to18kHz (+1 / -3 dB at -10 dB ref. rated output)-Distortion <1% @ rated output power, 1 kHz. -S/N (flat at max volume) >90 dB -Battery power supply:24 VDC +15% / - 15% Complete as required. 321 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speaker complete as required. 322 Supplyinganddrawing ofcableFireRetardantPVCinsulatedcopper conductor cable in the existing surface / recessed steel conduit of following pairs,coresandsizeincludingconnectionsandinterconnectionsetc.as required. Speaker cable Single pair, 2-core, 1.5 sqmm 323 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 1 run 324 Supplying,installation,testingandcommissioningof 24- portPOE+switch .Thefollowingtechnicaldataneedto comply which has been mentioned below: a.)Access Switch should have 24 ports of 100/1000 PoE+(802.3 at) RJ45 and minimum 2 ports of 10G (2 SFP+ for uplink).b.)TheAccessswitchshouldsupportminVLANs. c.)The Access Switch should support minimum stacking up to4units.Costofthestackingmodules/Portsshouldbe included.d.)TheAccessSwitchesshouldsupportlinkaggregation across the stack. e.)Theconnectedserversorswitchesshouldbeattached using standard LACP for automatic load balancing and high availability.f.)TheAccessSwitchshouldsupportfullLayer2features likeSTP,RSTP,MSTP,LAG,LACP,ACL,QoS.g.)The Access Switch should support basic L3 features like IPv4&IPv6static routing. h.)TheAccessSwitchshouldsupportIPv6management features like IPv6 ping, IPv6 trace route, IPv6 Telnet, IPv6 TACACS, IPv6 DNS, and IPv6 RADIUS.i.)All the ports should be usable at full power. 325 Supplying, installation, testing and commissioning of 5 MP- Full HD IP , 40 MTR IR Dome Camera , CMOS 1/2.8”, 3-8 mm with Remote focus and zoom, P-Iris control, IR corrected or better, Shutter 1/33000 s to 1/5 s or better, Up to 25FPSatallresolutions, Minimum4Streams@ H.265,5MP,25fps,WDR120dBorBetter, Inhouse processor with memory2048 MB RAM, 8192 MB Flash,Supportforrecordingtodedicatednetwork-attached storage(NAS),POE,AudioinSimplex,Builtinanalytics- Video MotionDetection, Humanand Vehicledetection usingMachine learning, Advance Motion Detection, Fence protection, Loitering,Tampering,Audiodetection,Support Edge based 3rd party analytics Humidity 10– 85%RH(Non-condensing),IK10orbetter, UL,FCC,EN,NDAAcompliant,NISTSP500-26705YearOEMwarranty.Thecamerashouldsendtriggervia HTTP/HTTPSto3rdpartydeviceforactivealerts.The Camerato beprovidedbythebiddershould nothave Hisilicon chipset/Processor and the camera should not support GB28181, GB/T 281812011; standards. There shouldbenooptiontoactivateordeactivateGB28181, GB/T 28181-2011 standards in the camera web page/Settings. 326 Supplying, installation, testing and commissioning of 5 MP- Full HD IP , 40 MTR IR Outdoor Type Bullet, Camera ,CMOS 1/2.8”, 3-8 mm with Remote focus and zoom, P-Iris control, IR corrected or better, Shutter 1/33,000 s to 1/5 s or better, Up to25FPSatallresolutions,Audiostreaming-Audioin, simplex, two-way audio via edge-to-edge technology, Minimum 4 Streams @ H.265, 5MP, 25 fps, WDR 120 dB or Better, Inhouse processor with memory2 GB RAM, 8 GBFlash,Supportforrecordingto dedicatednetwork- attached storage(NAS),POE,Builtinanalytics-Video MotionDetection,audiodetection,Fenceprotection, Loitering,ShockDetection,DeepLearningbasedHuman and Vehicle detection(types: cars, buses, trucks, bikes) Support Edge based 3rd party analytics Humidity10 -100% RH(-condensing), IP66/IP67-, NEMA 4X-, and IK10, IEC/EN/UL 62368-1,IEC/EN/UL60950-22,IEC62471,NDAAcompliant,NISTSP500267,IEC/EN62262 IK10, NEMA 250 Type 4X,EN61000-3-3,EN61000-6-1,EN61000-62,05YearOEM warranty .The camera should send trigger via HTTP/HTTPSto 3rdpartydevicefor active alerts.The Camerato beprovidedbythebiddershould nothave Hisilicon chipset/Processor and the camera should not support GB28181, GB/T 281812011; standards. There shouldbenooptiontoactivateordeactivateGB28181, GB/T 28181- 2011 standards in the camera web page/Settings 327 Supplying,installation,testingandcommissioningof32 Channel NVR expandable upto 150 Cameras with additionallicenses.Intel®Xeon®Silver,128TB(8x16 TB),TotalHDDslot:12,FreeHDDslot:0,Out-of-the-box storage:160TBafterRAID6,hotswappableEnterprise Class HDD, Factory RAID level: 6,RAID levels: 0, 1, 5, 6, 10, Operating system Microsoft® Windows® 10 Enterprise, Operating system drive: 240 GB SSD, Recording rate up to 1.5Gbit/s,Upto2x800Whot-plugredundantpower supplies,2x USB 2.0,1x USB 3.0,2x VGA,2x iDRAC dedicated Ethernet port,2x RJ45 1 Gbps, Humidity 20–80% RH (non-condensing),10 °C to 35 °C,IEC/EN/UL 60950-1, IEC/EN/UL 62368-1, EN 62311, NOM-019-SCFI- 1998,NDAA compliant.Support for encrypted operating system drive and recording drive FIPS 140-2 level 2 certified Trusted Platform Module (TPM 2.0). HDD Price Included in the NVR Price. 328 Supplying,installation,testingandcommissioningof64 Channel NVR expandable upto 150 Cameras with additionallicenses.Intel®Xeon®Silver,128TB(8x16 TB),TotalHDDslot:12,FreeHDDslot:0,Out-of-the-box storage:160TBafterRAID6,hotswappableEnterprise Class HDD, Factory RAID level: 6,RAID levels: 0, 1, 5, 6, 10, Operating system Microsoft® Windows® 10 Enterprise, Operating system drive: 240 GB SSD, Recording rate up to 1.5Gbit/s,Upto2x800Whot-plugredundantpower supplies,2x USB 2.0,1x USB 3.0,2x VGA,2x iDRAC dedicated Ethernet port,2x RJ45 1 Gbps, Humidity 20–80% RH (non-condensing),10 °C to 35 °C,IEC/EN/UL 60950-1, IEC/EN/UL 62368-1, EN 62311, NOM-019-SCFI- 1998,NDAA compliant.Support for encrypted operating system drive and recording drive FIPS 140-2 level 2 certified Trusted Platform Module (TPM 2.0). HDD Price Included in the NVR Price. 329 Supplying, installation, testing and commissioning of55 LED UHD Smart Professional Signage Display with Web OS, 500nits, 1000000:1 Dynamic Contrast Ratio , 24/7 operation, HDMI, DP, DVI-D, RS232, LAN,USB, WiFI, Screen share, 16GB inbuilt Memory,IP5X Dust Proof Certified Design, Built-in Speakers, Narrow Bezel, Super Sign CMS compatibity, with 1.1 Ghz Quad Core CPU , Clear View with Non Anti glare Coating complete as required. 330 Supply , Installation, Testing and Comissioning of 19U - Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable. etc complete as required. 331 Supply , Installation, Testing and Comissioning of 32U - Floormounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable. etc complete as required. 332 Supplying,Installation,Testing&Commissioning of Armoured06CoreSinglemode(OS2)9/125FiberCable, ITUG.652.D,G.657A1,OutdoorECCSArmoredFiber Cable. 333 Supplyinging and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 334 Supplying of the following sizes PVC insulated PVC sheathed armoured copper conductor cable etc. as required 4x16 sq mm copper cable ( From Lift pane to Lift) 335 3 x 4 sq.mm copper ( Shaftlighting) 336 Supplying and making end termination with brass compression gland and copper /Alluminium lugs for 4x16 sq mm of PVC insulated and PVC sheathed / XLPE copper/ Alluminiumconductor cable of 1.1 kV grade as required. 337 Supplying and fixing 63 amps rating, four pole, (three phase and neutral), 415 volts,Residual Current Breaker with Overload (RCBO), having a sensitivity current upto 300 milliamperes alongwith suitable Double Door enclosure complete with connections, testing and commissioning etc. as required. 338 Supply & Installation testing commissioning of HT Metering Cubicle panel as approved by DISCOMs fabricated out of 14 SWGCRCASheetsteelintwocompartmentandMSAngleofSize60mmx6mmhavingprovisionoffollowing:1). Provisionforfixingtrivectormeter(tobesuppliedby discoms)2).Provisionforfixing ofcombinedCT,PTset(tobe supplied by discoms) 3). TT Block 4). 6mm Backlite sheet on all sides 5). 3/6 core copper cable for interconnection etc. as required 339 Supplyingfollowing size 11 KV grade ( Earthed ) stranded, compact circular aluminium conductor screened with extruded Semi conducting compound, XLPE insulated, insulation screened with semi conducting compound in combination with copper tape, cores laid up, inner sheath of PVC tape, Galvanised steel roundarmoured and overall PVC sheathed cable conforming to IS:7098 / II /1985 with latest amendments in existing masonry duct/in pipe/on surface as required. 3 core 240 sq mm 340 Supplying and laying offollowing size double walled corrugated (DWC) high density polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS 14930 (Part-I & II) complete with necessary with HDPE fittings directly in ground at a depth of 75 cm i/c excavation and refilling the trench etc as required. 200 mm dia outer dia nominal size 341 supplying and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :3 x 240 sq mm 342 Supplying and fixing of following safety equipment at suitable location complete as required. Electrical insulation mat upto 11 KV grade of 2.5 mm thickness as per IS 15652 343 Supplying and fixing of following safety equipment at suitable location complete as required. Electrical insulation mat upto 3.3 KV grade of 2 mm thickness as per IS 15652 344 Supplying and fixing of following safety equipment at suitable location complete as required. First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 2217 - 1963. 345 Supplying and fixing of following safety equipment at suitable location complete as required. ROLLUP CHART OF ELECTRIC SHOCK & TREATMENTchart duly framed in glass of size(38 inch X 26 inch) 346 Supplying and fixing of following safety equipment at suitable location complete as required. 4 Nos 9.5 Litre capacity GI Bucket painted in post office red colour with prior coat of red oxide paint and written with white paint FIRE and mounted on MS angle iron frame with bracket of appropriate size & capacity i/c filling sand etc 347 Supplying and fixing of following safety equipment at suitable location complete as required. Mask and Respirator 348 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 349 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 350 Package Substation will have the following equipments: Outdoor type package substation 400 kVA, 11 KV/0.433V (Dry TYPE TRANSFORMER) 400 KVA, 11KV/.433KV, Dry type Compact substation consisting of- A) 11 KV, 630A, 21KA, Outdoor type 3 way RMU 2 manual operated LBS + 1 manual operated VCB with self-powered Numerical type O/C+E/F Relay & all other std accessories – 1 No. (Type – CCV). B) 400 kVA, 11 kV/ 0.433 KV, Dry type TransformerwithLossesasperIS11170–01 No. C) LT panel with following details BOM. CSS Compartment :TheEnclosureof Compact substationissuitableoutdoor/ indoortypeapplication fabricated in 2 mm GI sheets and duly painted. The base frame is hot dip galvanized and rust proof. The doors of enclosure are with stainless steel hinges and locks and all safety interlocksareprovidedtomakeittamperproof.Illuminationisprovidedinallthree compartments of CSS with all other standard accessories. HT Compartment : 11kV, 630A, 21KA, 3 way Ring Main Unit consisting of 2 Nos. Manual operated Load Break Switch and 1 No. Manual operated VCB with self-powered O/C+E/F Relay with series trip & all standard accessories. TheRMUwillbeencapsulatedinSF6tankandhavingManual/MotorizedON/OFF/ operations & Manual EARTH operations. Voltage presence indicator, FPI, pressure gauge, counter, mimic diagram, interlocking and padlocking facility etc. Transformer Compartment : 400 kVA, 11/0.433 kV, DYN 11 ONAN, Dry type OCTC Transformer with off circuit tapping +5% to -5% @ 2.5% per step as per IS 11170. LT Compartment:630 A, 4P, 50KA, MF Type ACB, 6 fuse with fuse base assembly sets with DTC meter as per Local Electricity Board standard specifications. NOTE : Interconnection of all control Cable and Accessories etc complete in the scope of supply, including Foundation as per manufacture recommendations& complete in ready to use condtion. 351 MAIN LT PANEL - Supplying,installation,testing&commissioningof Main LTpanelsuitable for415V,3Phase,4 Wire50HzACsupplysystemfabricatedin compartmentalizedsuitable size (preferably)designfromCRCA sheet steel of2mmthickforframework,3mmthickforgland,platesi/ccleaning& finishingcompletewith7tankprocessforpowdercoatinginapproved shade,having 2000 Amp capacity extensibletypeTPNaluminumalloy busbarsof high conductivity,DMC/SMC bus bars supports, with short circuitwithstandcapacityof 31MVAfor1sec.,bottombasechannelof MSsectionnotless than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 20mm x 5mm at the rearwith 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars andcontrol wiring with 1.5 sqmm PVC insulated copper conductor S/Ccable,cableglandplatesintwohalf,i/cproviding following switch gears: INCOMER: Transformer & D.G Set 2 Nos. 630 Amps Four Pole ACBoffaultbreaking capacity50KAIcs=Icuupto433V,fittedwithinterlocked door, automatic safety shutters,mechanical ON/OFF and service/test/isolated positionindicatorsandframeearthingcontact, conformingtoIS1397-2:1993asamendedup-to- datecompletewith followingaccessoriesforeach ACB. Independent manual spring closing mechanism- 4 Nos. MP release (EMI & EMC certified) for over current, earth fault & short circuit protection- 4 Set. R/Y/B Phase Indication Lamp with control MCB-4 Set And 2000/5A 15VA CL:1 CTs -03 Nos each – 4 set Digital A,V KWH METER WITH RS485-02 Nos. LOAD MANAGER WITH THD & RS 485 BUS COUPLER: 1 No. 630 Amps Four Pole ACB of fault breaking capacity50KAIcs=Icuupto433V,fittedwithinterlocked door, automatic safety shutters,mechanical ON/OFF and service/test/isolated positionindicatorsandframeearthingcontact, conformingtoIS1397-2:1993asamendedup-to- datecompletewith followingaccessoriesforeach ACB. BUS BAR 800 Amp TPN Aluminium busbars OUTGOING: 400 A TP 36KA MCCB TMRelease O/L, S/C Protection with ROHM, Spreader Link - 1 Nos. 315 A TP 36KA MCCB TMRelease O/L, S/C Protection with ROHM, Spreader Link - 2 Nos. 200ATP25KAMCCBTMO/L,S/CProtectionwithROHM, Spreader Link - 2 Nos. 160ATP25KAMCCBTMO/L,S/CProtectionwithROHM, Spreader Link - 2 Nos. 125ATP25KAMCCBTMO/L,S/CProtectionwithROHM, Spreader Link - 2 Nos. 100ATP25KAMCCBTMO/L,S/CProtectionwithROHM, Spreader Link - 2 Nos. 63ATP25KAMCCBTMO/L,S/CProtectionwithROHM, Spreader Link - 4 Nos. Digital Ampere Meter along with Suitable CT’s (Each Outgoing) Control SP MCB C CURVE 10KA (Each Outgoing) 352 205 KVAR APFC PANEL - Supplying, installation, testing and commissioning of floor mounted 205 KVAR APFC panel made out of CRCA sheet of 2 mm thick, gland plate is of 3 mm thick including finishing complete with 7 tank process for powder coating in approved shade, having 400 Amp capacity aluminum bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x50mm x5mm thick,fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 20 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections frommainbusbartoswitchgearswithrequiredsizeofAlbusbarsand control wiring withPVC insulated copper conductorS/C cable, cable alleys, cable gland plates in two half, including providing following switch gears auto- manualcapacitorbank of205KVARcapacityhaving3PhaseMPPtypefor 440V, The system shall have microprocessor based APFC relay provided in the INCOMER: 315A, MCCB 25KA - 1 no. Indicating Lamps, LED Type, Red, Yellow, Blue Digital Voltmeter/ Ammeter Meter - 1 no. Current Transformer, 1250/5A, Cl-1.0, 15VA- 1 Set APFC Relay 14-Step Outgoing-5 KVAR CAPACITOR BANK- 3 No. 16 Amp. TP MCB, 10KA, - 1 No. 5 kVAR Electronic Thyristor Modules -1 set 5 kVAR MPP-Heavy Duty Capacitor with 7% detuned reactor- 1 set. Indicating Lamps, LED Type, ON(Red) – 1Set Auto/Manual Selector Switch -1 Set Outgoing-15 KVAR CAPACITOR BANK- 6 No. 32 Amp. TP MCB, 10KA, - 1 No. 15 kVAR Electronic Thyristor Modules -1 set 15 kVAR MPP-Heavy Duty Capacitor with 7% detuned reactor, - 1 set Indicating Lamps, LED Type, ON(Red) - 1Set Auto/Manual Selector Switch -1 Set Outgoing-25 KVAR CAPACITOR BANK- 4 Nos. 50 Amp. TP MCB, 10KA, - 2 No. 25 kVAR Electronic Thyristor Modules -2 set. 25 kVAR MPP-Heavy Duty Capacitor with 7% detuned reactor- 2 set Indicating Lamps, LED Type, ON(Red) – 2 Set Auto/Manual Selector Switch -1 Set 353 Supplying of following sizes PVC insulated PVC sheathed XLPE aluminium conductor armoured LT cable of 1100 V as per IS 1554(Part I) and having ISI marking etc. as required3.5 X 150 sq. mm 354 3.5 X 240 sq. mm 355 EXTERNAL LIGHTING PANEL Supply, installation, testing and commissioning of following outdoor type with canopy, min front area 4.8 sq.mtr and 400 mm depth,IP-54 protected M.V. cubicle type totally enclosed, free standing type, dust, damp and vermin proof, MV Panel, busbars, M.V. danger notice plate, interconnections with suitable capacity aluminium leads/solid aluminium strips/rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing switchgears complete as required. INCOMER: 63 Amps,415 volts, TP+NL, 35 KA Moulded Case Circuit Breaker with thermal magnetic release having variable current settings . R,Y&B phaseindicating lamp (LED type) with 2A control SP MCB ,ON, OFF , TRIP for MCCB Extended rotary operating mechanism with door interlocking with defeat feature and padlock facility. MCCB should have spreader links & phase barriers. 1 Set of timer switch & 100A TP contactor with nuetral link (for street lights control) . BUSBARS: 100 Amp TPN Aluminium busbars OUTGOING: 18 Nos. 16 Amp 415 volts, DP MCB (Feeder Pillar asmentionabove ) 356 Fabrication, supplying anderection of 6 mtr.height flange mounted hot dipped galvanized octagonal poles made out from 3 mm thick high tensile strength steel, bottom dia. - 130 mm & top dia. - 70 mm, window at 0.5 m from the base with flush cover, cable termination, 4 nos. 16 mm dia. x 600 mm long GI foundation bolt with nuts & washer, 2 nos. templates of 3 mm thick size 200 x 200 mm, galvanized base plate of size 200 mm x 200 mm x 12 mm thick on existing cement concrete pedestal, including welding and following accessories complete as reqd S/F of3 mm thick suitable size laminated sheet and 2 Nos. 4 mm thick of suitable size G.I. striphaving tapped holes inside the window as reqd. S/F of 6 Amp SP MCB C curve -1 No., din channel, heavy duty bolt type connecter, earth stud complete withspring washers, bolts & nuts, etc. 1 mtr single/Double arm cap type bracket-1 No. 357 Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.Above 6.5 metre and upto 8.0 metre 358 Supplying, installation, testing and commissioningof Astronomical time switchof following configuration to be mounted in feeder pillars / Lighting DBs forautomatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.1 output per phase and suitable for single phase supply 359 Supply, Installation, Test & Commissioning of 35W LED Decorative Post Top type luminaire with System efficacy of 100 lm/W (3500 lumens), suitable for external poles of dia. 65mm to 75mm with integrated light havig asymmetric light distribution . Luminaire shall be made up of pure polyster power coated RAL7021 pressure die cast Aluminium housing with Polycarbonate Fresnel lens of symmetrical or street optics of same make. All external hardwaremust be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 and IK07 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing).The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM <5.LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting.LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 150-300V AC. Driver Efficiency > 85% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 should be there. 360 Supply, Installation, Test & Commissioning of200W SMD LED Floodlight fixture with System efficacy of 120 lm/W (24000 lumens). Luminaire shall be made up of LM6/ADC12 Alloy, non-corrosive, pure polyster power coated die cast Aluminium housing with PC lens. The housing should be completely screwless. Lumianire should be of dimension 350mm x 360mm x 50mm height ± 5mm height and the approximate weight should be within the 4.0Kg ± 0.25Kg. Luminaire should have 60° beam angle for uniform light distribution. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 1W-2W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK07 protection. It should be cabable to operating under ambient temperature range of 0°C to +45°C. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM < 5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 140-300V AC. Driver Efficiency > 85% & 5 KV internal surge protection with additional 10KV SPD mounted inside the luminaire and firmly fixed to the housing, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit, open circuit, Auto cut-off protection for low and high input voltage. Driver must have 440V input voltage protection for 8 hours. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. 361 Less 5% as per Govt. Approoval 362 Supplying, installing, testing & commissioning of 20 passenger (1360 Kg) lifts having contract speed of 1.5 mps serving different floors in the existing liftshaft as per detailsbelow and CPWD General specification for electrical works (Lifts & Escalators) upto date etc. as required. Speed : 1.5 MPS Floors:G + 4 Travel : 20 Metres (approx.) Stops & opening :5 Nos. All openings on same side. Controller : Microprocessor based duplex full collective control Automatic rescue device complete with dry Maintenance free batteries as required. Drive : VVVF Operation : Microprocessor based single automatic push button / duplex selective collective with / without attendant i/c safety facilities. Power : 415 V, 3 Phase, 50 Hz, 4 wires system. Doors : Power operatedcentre opening horizontal sliding stainless steel Scratch Proof in Honey comb finish. Car : Power operated centre opening horizontal sliding stainless steel honey comb finish. Floor annunciator with light music. Intercom 3 way. Digital position indicators (TFT type ) (in car and at all landings). Battery operated emergency light and alarm bell. Full length Infrared door screen. Vandal proof S.S.Button with S.S. cover i/c. LED illumination with braille signages at all landings and car. Mirror of suitable size on rear panel inside the car. Car lighting L.E.D.fittings and cabin fan (cross Axialflow blower fans with louver and atleast 2 nos fan) SS Hand rail at 900 mm above floor level on rear and bothsides of the car.control button at height 800 to 1000 mm Flooring - Engineering Marble/ Granite 363 Supplying, installing, testing & commissioning of Good Lifts (1000 Kg) lifts having contract speed of 1.0 mps serving different floors in the existing liftshaft as per detailsbelow and CPWD General specification for electrical works (Lifts & Escalators) upto date etc. as required. Speed : 1.0 MPS Floors:G + 4 Travel : 20 Metres (approx.) Stops & opening :5 Nos. All openings on same side. Controller : Microprocessor based duplex full collective control Automatic rescue device complete with dry Maintenance free batteries as required. Drive : VVVF Operation : Microprocessor based single automatic push button / duplex selective collective with / without attendant i/c safety facilities. Power : 415 V, 3 Phase, 50 Hz, 4 wires system. Doors : Power operatedcentre opening horizontal sliding stainless steel Scratch Proof in Honey comb finish. Car : Power operated centre opening horizontal sliding stainless steel honey comb finish. Floor annunciator with light music. Intercom 3 way. Digital position indicators (TFT type ) (in car and at all landings). Battery operated emergency light and alarm bell. Full length Infrared door screen. Vandal proof S.S.Button with S.S. cover i/c. LED illumination with braille signages at all landings and car. Mirror of suitable size on rear panel inside the car. Car lighting L.E.D.fittings and cabin fan (cross Axialflow blower fans with louver and atleast 2 nos fan) SS Hand rail at 900 mm above floor level on rear and bothsides of the car.control button at height 800 to 1000 mm Flooring - Engineering Marble/ Granite