| Sl. No. | Item Description |
| 1 | Attending day to day external water supply complaints of all nature of CI/GI pipe line size upto 100 mm bore at ADRDE Lab & Colony/Raksha vihar/Vigyan vihar i.e. leakage in water supply pipe lines , fittings/fixtures, over flow of overhead tank, no water supply and depute skilled labours for attanding complaint complete all as specified and as directed. Note :- Quoted rates includes following other aspects as:a) While attending the complaint of water supply leakage if earth work is required above oneCum then the same shall be measured and paid seperately under respective item of Sch \"A\" . However no extra payments shall be made for dewatering.b) Cutting of old rustedCI/GI pipe in position replace with new pipe(short lengths upto to one running meter) incl threading is also deemed to be included in the job rate.c)Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items from 1.01 to 1.16 of Sch Ad)Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. e)All T & P including safety gears required for attending the complaints shall be provided by the contracor. |
| 2 | Supply only GI Elbow of size upto to 25 mm bore \"Medium\" grade ofany type ISI Marked. |
| 3 | All as per item no 01.01but for 32 to 50 mm bore |
| 4 | All as per item no 01.01but for 80/100 mm bore |
| 5 | Supply only GI Socket size upto 25 mm bore \"Medium\" grade ISI Marked. |
| 6 | All as per item no 01.04 abovebut for 32 to 50 mm bore |
| 7 | All as per item no 01.04 abovebut for 80/100 mm bore |
| 8 | Supply only GI Union size upto to 25 mm bore \"Medium\" grade ISI Marked. |
| 9 | All as per item no 01.07 abovebut for 32 to 50 mm bore |
| 10 | All as per item no 01.07 abovebut for 80/100 mm bore |
| 11 | Supply only GI Nipple upto 40mm bore\"Medium\" grade in different lengths upto 300 mm all as per requirement, both end screwed. |
| 12 | Supplyonly GI Socket Reducing socket upto 40 mm bore \"Medium grade\" of any size & typeISI marked. |
| 13 | Supplyonly GI Socket Reducing socket50/80 mm bore \"Medium grade\" of any size & type ISI marked. |
| 14 | Supply onlyGI Teeupto 25 mm bore \"Medium grade\" of any size & type ISI marked. |
| 15 | Supply onlyGI Tee32/40 mm bore \"Medium grade\" of any size & type ISI marked. |
| 16 | Supply onlyGI Tee50 mm /80 mm bore \"Medium grade\" of any size & type ISI marked. |
| 17 | Supply onlyGI Tee 100 mm/150mm bore \"Medium grade\" of any size & TypeISI marked. |
| 18 | Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line & other works like LT/HT cable etc in hard/ dense soil, getting out and levelling of bottom surface to required complete all as specified and as directed. Note:- The disturbed surface of roads/ paths/ plinths etc shall be repaired adn shall deemed to be included in quoted rates. |
| 19 | Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified and as directed. |
| 20 | Removing excavated material from site to a distance not exc 50 m away and depositing where directed not exc 1.5 meters above the starting point all as directed. |
| 21 | Supply and laying 100mm dia bore Cast iron pipeswith flanged ends, centrifugally cast, class A, in any length laid in trenches including taking out old unserviceable complete all as specified and directed |
| 22 | All as per item ser No 5.00 above but 80mm bore. |
| 23 | M&L in repair for cast iron Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross(all sockets or socket and spigot) collars, caps and plugs,up to 150 mm bore, for spigot socketed pipesconfirming to IS: 1538-1993 complete all as specified and directed. |
| 24 | Supply & fixing, CI sluice valves of 80mm bore in existing valve pit chamber/any other position class PN 1.6 ISI mark flanged ends drilled having stainless steel spindle with cast iron wheel at top complete withincluding nut and bolts washers and rubber gasket, taking down old unsv sluice valve complete all as specified and as directed. |
| 25 | All as per item ser No 8.00 above but for 100mm bore. |
| 26 | M&L for taking out old unserviceable burnt winding of centrifugal motor 7.5 to 15 HP capacity, 3 phase,415 volts,50 Hz,AC supplyafter disconnecting all electrical connections and rewinding by usingsuper enamelled copper conductor of existing gauge and size by maintaining existing turn ratio, applying insulation varnishand drying up to specified period to achieve desired insulation value including reassembling of motor after rewinding and testing and connecting all electrical connection using suitable size of lugs complete all as specified and directed. |
| 27 | Transporting of Submersible/ Centrifugal Pump Set any capacity from Pump House/ E&M store yard at ADRDE/Vigyan Vihar/Raksha Vihar to nearest workshop for repairing including carefully loading/ unloading and back to old location etc complete all as specified and directed |
| 28 | Liftingout/ taking up carefully submersible Pump Set and motor from bore well after disconnecting electrical and pipe line conections with the help of chain pully block with tripod including column pipe and submersible cable from 240 feetapprox depth, disconnecting pump and motor from couplingand keeping aside for testing / checking submersible pump set and other connected acessories for servicibility complete all as specified and directed Note : T&P required shall be provided by the contractor and rates for the same are deemed to be included in quoted rates. |
| 29 | Taking out unserviceable impeller and casing from the pump upto 15HP and replacing with new impeller and casing of same size / type as per the existing one complete all as specified and directed. |
| 30 | Taking out old unserviceable burnt winding of submersible motor 10/12.5/15 HP, 3 phase 415 volts, 2900 RPM, 50 Hz AC supply and rewinding usingcopper super enamelled conductor PVC insulated of existing gauge and size by maintaining existing turn ratio and reassembling of submersible motor after rewinding by replacing burn out parts complete all as specified and directed. Note : (i) Spare parts require to replace (Neck ring,Shaft sleeve,coupling key,impeller key, water seal,distance sleaves,rotor shaft etc)shall also be included in quoted rate.(ii) Lifting and lowering shall be measured & paid under item No 12 &17 of BOQ respectively. |
| 31 | Taking out old unserviceable submersible/centrifugal motor of 12.5 HP capacity, 3 phase,415 volts,50 Hz,AC supplyafter dismantelling and replace with new motor of exsisting size & typeincluding reassembling of motor after the replacement, testing and connecting all electrical connectioncomplete all as specified and directed. |
| 32 | Labour only for reassembling ofsubmersible/centrifugal pump after repairing and by replacing burnt out parts complete all as specified and directed Note : Spare parts required to be replaced if any shall be measured & paid separately as supply only. |
| 33 | Lowering down, submersible Pump Set and motor by deploying skilled labour inside bore well, with the help of chain pully block with tripod including column pipe and submersible cable up toapprox depth240\", after connecting pump and motor with coupling, and making electrical and pipe line connections etc complete all as specified and directed Note : Lifting up shall be measured & paid under item No 12.00 of BOQ |
| 34 | S&F Submersible cable, PVC insulated, multistranded copper conductor, 1100 volts grade, 3 core flat of size 10 Sqmm including taking out old unserviceable complete all as specified and directed |
| 35 | S&F in repair foot valve 80 mm bore, ISI Marked, Brass body, heavy duty having one end flanged or internal screwed suitable to fix in suction pipe and other side strainer with leather flape and counter weight including all fixing arrengements as new nuts, bolts, washers and gasket including testing complete all as specified and directed. |
| 36 | All as per item ser No 19.00 above but 100mm bore. |
| 37 | S&F in repair of Automatic star delta starter suitable for motor upto 15 HP in sheet metal enclosure, suitable for submersible / centrifugal pump set with relay, contactor, auxilary contactor suitable to run on 440 volts, 50 Hz, AC supply complete all as specified and directed |
| 38 | S&F 100mm dia medium gradegalvanisedsteel water tubes with screwed joints together with andincluding allGI fittings such as bends, tee, unions, sockets short piece connection, backnuts, caps plugs, union coupling, flanges, socket etc laid in trenches and including earth work and removing old pipeline complete all as specified and as directed. Note:- (i) The rates quoted inclusive of earth work,cutting, jointing and leakage testing of the pipe. |
| 39 | All as per item ser No 22.00 above but 80 mm bore. |
| 40 | All as per item ser No 22.00 above but 50 mm bore. |
| 41 | All as per item ser No 22.00 above but 40mm bore. |
| 42 | All as per item ser No 22.00 above but 25mm bore |
| 43 | All as per item ser No 22.00 above but 20mm bore |
| 44 | S&F of 50 mm bore GI pipe medium grade with all new to fittings and fixed complete on walls and ceilings or laid in floors conncetion lines including removing old pipe line complete all as specified and directed. Note :- (i)leakage testing is deemed to be included in quoted rates. (ii) Cutting chasing and making good the surface shall deemed to included to be included in quoted rates. |
| 45 | All as per item ser No 28.00 above but 40mm bore. |
| 46 | All as per item ser No 28.00 above but 25mm bore. |
| 47 | All as per item ser No 28.00 above but 20mm bore. |
| 48 | All as per item ser No 28.00 above but 15mm bore. |
| 49 | Cuttingroad / hard standing to a size not exceeding 30cm in width and not exceeding 90 cm in depth for removal/ laying of GI pipe upto 100mm bore including making good so as to match with the existing finishes using PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) 100 mm thick complete all as directed. |
| 50 | Taking down rusted CI (cast iron) sluice valve of 100mm bore and transporting to the nearest workshop for servicing including greasing replacing the gasket, make the valve functional and refixing in the same position complete all as specified and directed. |
| 51 | All as per item ser No 34.00 above but 80mm bore |
| 52 | S&F 50 mm bore Gun metal globe or gate valve with iron wheel head, ISI marked screwed both ends for iron pipes in position including removing old unserviceable valve complete all as specified and directed. |
| 53 | All as per item ser No 36.00 above but 40mm bore |
| 54 | All as per item ser No 36.00 above but 25mm bore |
| 55 | All as per item ser No 36.00 above but 20mm bore |
| 56 | Supply and fix in repair of 150mm PVC raising main pipe line exsisting type including all fittingsshort piece connection,etc laid in trenches and including earth work and removing old pipeline complete all as specified and as directed. Note:- (i) The rates quoted inclusive of dewatering,cutting, jointing and leakage testing of the pipe. |
| 57 | Supply and fix in repair of 100mm PVC raising main pipe line exsisting typeincluding all fittings short piece connection,etc laid in trenches and including earth work and removing old pipeline complete all as specified and as directed. Note:- (i) The rates quoted inclusive of dewatering,cutting, jointing and leakage testing of the pipe. |
| 58 | S & F uPVCpipe with 50 mm nominal dia ,heavy duty suitable forrating 10 kgf/cm2laid in trenchesincluding necessary eathwork and removeal of old unserivceable pipe completeall as specified and directed. |
| 59 | S & F for fixing of 50 mm uPVC Ball valve in position complete all as specified and directed |
| 60 | S & F in replacement uPVCpipe with 50 mm nominal dia ,heavy duty suitable forrating 10 kgf/cm2laid infixed complete towalls, ceilings or infloors etc., completeall as specified and directed. |
| 61 | M&Lfor bore wellcleaning / washing of tube well by using acompressorup to 250mm bore and upto 150 mtr depth by removing the submersible Pump set 12/ 15 HP capacity, column pipe, power cable with the help of tripod and chain pulley block and remove the dirts sludge, mud, clay, sand, scales from top to bottom level with the help of compressor for smooth functioning of the submersible pump including lowering down the pump and testing the suction of potable water from the borewell complete all as specified and directed |
| 62 | S&F in repair of structural steel work such as angle iron, flat, MS plates etc for fabrication base frame of Centrifugal pump set complete all as specified and directed. |
| 63 | Taking out old unserviceable burnt winding of Monoblock motor upto 5HP capacity, single phase,240 volts,50 Hz,AC supplyafter disconnecting all electrical connections and rewinding by usingsuper enamelled copper conductor of existing gauge and size by maintaining existing turn ratio, applying insulation varnishand drying up to specified period to achieve desired insulation value including reassembling of motor after rewinding and testing and connecting all electrical connection using suitable size of lugs complete all as specified and directed. |
| 64 | S&F cast iron 100 mm bore non return valve swing check single door pattern conforming to IS-5312 heavy duty ISI marked with CI drilled flanged ends internally cast including jointing materials complete such as rubber fibre board insertion packing ring nuts bolts and washers of required size etc including taking out old unserviceable complete all as specified and directed |
| 65 | All as per item ser No 48.00 above but of size 80 mm. |
| 66 | M&L for cleaning RCC underground sumps/over head tank internally including bailing out of water below foot valve level, removing all scale and dirt etc from tanks and mouth of circulating pipes by brushing and washing with bleaching powder andwater pressure removing silt outside MD land and applying two coats of white wash to external & top surface and writing down the date of cleaning in the format \"Tank Cleaned on DD/MM/YYYY\" format letter exc. 12.5 cm but n exc 15 cm in height with synthetic enameled paint including preparation of surface complete all as specified and directedof the following capacities and location :- |
| 67 | Capacity 15000.00 gallon or 68200.00 Ltr OH RCC Tank at ADRDE Complex area Pump House |
| 68 | Capacity 15000.00 gallon or 68200.00 Ltr UG RCC sump at ADRDE Complex area Pump House |
| 69 | Capacity 7000.00 gallon or 31900.00 Ltr UG RCC sump at ADRDE Complex area Pump House - 02,MES office complex-01 |
| 70 | Capacity 13200.00 gallon or 50000.00 Ltr UG RCC sump at Raksha Vihar Pump House |
| 71 | Capacity 20000.00 gallon or 90900.00 Ltr OH RCC tank at Vigyan Vihar area Pump House.Note for 50.01 to 50.05(i) Dewatering of overhead tank by drain out pipe.(ii) Mechanized removal of all remaining dirty water by high- capacity pump set.(iii) Removal of sludge by vacuum operated Pump.(iv) Cleaning of walls, ceiling and bottom of tank by high pressure rotary jet 120 bars pressure.(v) Removal of all dirty particles by industrial wet vacuum cleaner leaving the tank 99.9% physically cleaned.(vi) Sterilization of tank by Eco-Friendly biodegradable and highly effective anti bacterial non toxic agent approved by NTC (National Toxicology Center) against all pathogens agent of tank clean. (vii) Sterilization of tank atmosphere by industrial UV radiator leaving the tank complete Sterlite by specialized method(viii) The work will be got executed from the reputed specialized water tank cleaner as approved by GE.(ix) All the sludge materials / fungi removed from the underground sump / semi underground sump and over head tanks will be removed outside defence land from the site.(x) All underground sump / semi underground sump and overhead tanks will cleaned in all respect upto 3 mtr around the water tanks.(xi) T&P required for all the above aspects shall be arranged by the contractor. (xii) The quoted rate is deemed to included all the above aspects. |
| 72 | M&L for run lead joint of size 100 mm dia bore, cranking and making the joint leak proof including taking out old unserviceable complete all as specified and directed |
| 73 | All as per item ser No 51.00 above but 80 mm bore. |
| 74 | Supply, laying and testing of CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPES (SDR-11) Pipes of 50mm(Outer dia)ISI marked as per IS:15778 tough, rigid ,pipe cutting fixing with CPVC solvent cement and testing laid in trenches including removing old unserviceable pipe line complete all as specified and directed. Note :Quoted rate shall include of earthwork and provision of special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, Unions, Flange etc. |
| 75 | All as per item Ser No 53.00 above here-in-before but40 mm dia bore. |
| 76 | All as per item Ser No 53.00 above here-in-before but25 mm dia bore. |
| 77 | All as per item Ser No 53.00 above here-in-before but20 mm dia bore. |
| 78 | Supply, laying and testing of CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPES (SDR-11) Pipes of 50mm(Outer dia)ISI marked as per IS:15778tough, rigid ,pipe cutting fixing with CPVC solvent cement and testing laid in floors,wall,ceilings including removing old unserviceable pipe line complete all as specified and directed.Note :(a) Quoted rate shall includingof necessary special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, Unions, Flange and tank adaptor.(b) The ratesinclude for cutting chases in wall, floors etc and their making good in case of concealed pipe work. |
| 79 | All as per item Ser No 57.00 above here-in-before but40 mm dia bore. |
| 80 | All as per item Ser No 57.00 above here-in-before but32 mm dia bore. |
| 81 | All as per item Ser No 57.00 above here-in-before but25 mm dia bore. |
| 82 | All as per item Ser No 57.00 above here-in-before but20 mm dia bore. |
| 83 | S & F for 20mm CPVC Ball valve fixed in position complete all as specified and directed |
| 84 | All as per item Ser No 62.00 above here-in-before but25 mm dia bore. |
| 85 | All as per item Ser No 62.00 above here-in-before but32 mm dia bore. |
| 86 | All as per item Ser No 62.00 above here-in-before but40 mm dia bore. |
| 87 | All as per item Ser No 62.00 above here-in-before but50 mm dia bore. |
| 88 | S&F in repair Float valve with epoxy coated aluminium rod and high density ballofsize 20 mm bore dia complete all as specified and directed. |
| 89 | S&F in repair Float valve with epoxy coated aluminium rod and high density ballofsize 25 mm bore dia complete all as specified and directed. |
| 90 | Supply and fixing in replacement of unserviceable water gauge of range 0-100 PSI, by making hole 80/100mm dia GI pipe line fixed alongwith the needle volveto control pressure in delivery line with including socket welding in pipe line complete, all as specified and directed. |
| 91 | Taking up or down steel tubing of 25/32mm mm dia bore from floor/wall/trenches disconnecting all fittings including cleaning the pipe for removal rust and deposit to MES store all as specified and as directed. |
| 92 | All as per item Ser No 70.00 above here-in-before but 40/ 50mm dia bore. |
| 93 | Refixing/relayingold steel tubing of 25/32mm mm bore in new or old position on floor/wall/trenches including new GI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including existing connection with required size of Tee or MS clamp with rubber bush all as specified and directed. Note: GI piperetrieved from item No. 70.00 here-in-before shall be used after cleaning. |
| 94 | All as per item Ser No 72.00 above here-in-before butfor 40/ 50mm dia bore.Note: GI piperetrieved from item No. 71.00 here-in-before shall be used after cleaning. |
| 95 | Sampling of non chlorinated water from various pump houses under AOR of AGE R&D Agra as and when directed by Engineer-in-Charge and testing the water for bacteriogogical, Physical and chemical as per IS-1622 and 3025 from any Government/NABL approved laboratories and submission of test report to Engineer-in-Charge within 10 days ofdirection for testing as directed by Engineer-in-Charge complete all as specified and directed .Note:- Rate Quoted shall also deemed to be included for the followings (i) Cost of sterilized bottle as required.(ii)Collection of samplling water should becarried out in presence of JE/Engineer-in-Charge.(ii) Transportation charges for collection of samples from source (UG sump, bore & shallow wells)Test reports so collected will be submitted to the Engr-in-Charge |
| 96 | Cutting existing CI pipe line of 80/100 mm dia for insertion of new tees, collars for branch connections complete all as specified and directed Note: Quoted rate shall be including of CI /DI specials, Joints and Earth work |
| 97 | Arrestingleakages of 100 mm bore sluice valves by replacing Gland packing, gland bush, gland flange, nut bolts, gasket, packing material as required after dismantling in existing positionincluding testingon completion complete all as specified and directed.Note: Quoted rates inclusive of the materialsmentioned above like Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required to arrest the leakages. |
| 98 | All as per item Ser No 76.00 above here-in-before but80 mm dia bore. |
| 99 | Repair to the existing valve pit chamber of following sizes by demolishing the existing bricks work and foundation concrete and M&L for 230 mm thick brick walls of following size valve pit complte with mild steel sheet cover of 1.8 mm thick and angle iron of size 50x50x6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement and lifting handle and plastering in cement mortar 1:4 and 10 mm thick plaster to all internal and external exposed surfaces including two coats of white wash on wall complete all as directed. |
| 100 | Valve pit size 1200x1200x900 mm |
| 101 | Valve pit size 900x900x900 mm |
| 102 | Valve pit size 600x600x350 mm |
| 103 | Disconnecting all the connections ofrepaired DOL/oil immersed starter/auotmatic star delta starter of existing submersible/centrifugal motor upto 15 HP, 3 Phase 415V replace defective parts with new parts as per existing model/ type reassembling/ refixing the starter with necessary connection after the repairas required for proper functioning of motor commplete all as directed.Note: Quoted rates inclusive ofall required spare parts like contactor,auxilary contactor,thermal relay unit,no volt coil,terminal block etc. |
| 104 | S & F Framed work in repair such as grillsfor Staircase etc, gratings, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165complete all as specified and directed.Note :- (i) Work is to be executed in RCC over head tank for fixing of new steel to existing RCC over head tank uptp 21 mtr approx height is deemed to be included in quoted rates. (ii) During execution of work, the existing structure if damaged shall be rectified by contractor without any extra cost.(iii) Necessary T&P and safety measures including scaffolding for removing existing structur and fixing new structure. |
| 105 | Taking out suction pipe 80 mm to 150 mm bore from sump of any capacity, dismantling of foot valve screwed / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes of sizes etc complete all as required and as directed. |
| 106 | S&F in replacement 70 W LED, energy saving, environment friendly, long life exclusive innovating dia cast aluminium IP-66 protection, flood light suitable for highway lighting and general purpose including fixing arrangement and fixed on overhead tank\"s pillar / pump house complete all as specified and as directed. |
| 107 | Supply, fabrication and fixing inreplacement of valve chamber/UG Tank cover/RCC OH openning covers fabricated from 3mm thick MS sheetwith suitable size ofMS angle iron frame including locking arrangement, suitable handle , fixed with hinged arrangement and applying two coats of synthetic enameled paint over a coat of red oxide primer complete, all as specified and directed. |
| 108 | Removing old rusted pipe line of 100mm boreGI raising main pipe under the over head RCC tank(18/21 Mtr height) and M&L for fixing of 100 mm boreNew GI pipe medium grade with all fittings and connecting sluice valve ,supporting frame etcall as specified and as directed by Engineer-in-Charge . Note:- a. Neacessary scaffolding and manual/mechanical liftting arrangement to fixing the pipe shall be included in the quoted rate b. Removing exisiting sluice valve and refixing with new pipe also included in the quoted rate |
| 109 | Removing/Taking up CI/steel tubing of 100mm dia bore laid in trenches disconnecting all fittings including cleaning the pipe for removal rust and deposit to MES store all as specified and as directed. |
| 110 | All as per item Ser No 85.00 above here-in-before but 80mm dia bore. |
| 111 | Refixing/relayingold CI/steel tubing of 100mm dia bore in new or old position in trenches including new GI/CI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including connection with exsisting pipe line ,required size of Teeall as specified and directed. Note: Piperetrieved from item No. 85.00 shall be used after cleaning. |
| 112 | Refixing/relayingold CI/steel tubing of 80mm bore in new or old position in trenches including new GI/CI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including connection with exsisting pipe line ,required size of Teeall as specified and directed. Note: Piperetrieved from item No. 86.00 shall be used after cleaning. |
| 113 | Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches,pillars etc and removal of debris outside MoD land complete all specified and directed. |
| 114 | M&L for brick work with fly ash bricks, old size, class designation 75(Kgf/cm2) straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed. |
| 115 | M&L for rendering 15mm thick in cement mortar 1:4 on brick/concrete surfaces finished even & smooth without using extra cement etc complete all as specified and directed. |
| 116 | M&L for applying two coat of cement base paint over one coat of alkali resistant primer including preparation of new plastered brick/concrete surfaces as specified and directed. |
| 117 | M&L for PCC 1:2:4type B0 (using 12.5mm graded stone aggregate) as incoping etc including use & waste of form work in any position and shape complete all as specified and directed. |
| 118 | Excavating in post holes in soft loose soil (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm |
| 119 | M&L for plain Cement concrete type C-2 1:3:6 (40mm graded stone aggregate) as in foundations, filling and massconcrete complete all as specified and directed. |
| 120 | Demolition of RCC chajjas, slab, beamand similar work and removal of debris outside MoD land complete all as specified and as directed. |
| 121 | M&L RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as inSlabs supported on walls, beams and columns in floo roofs, landings, balconies, canopies, deck slabs and inshelves and the like of RCC over head tanks,all as specified and directed. |
| 122 | Use & waste of formwork to bottom and side of suspended slab such as roof slabs, floorslabs, landings and similar worknot exceeding 200mm thick(Horizontal or sloping) all as specified and directed by Engineer in Charge |
| 123 | Use & waste of formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat all as specified and directed. |
| 124 | M&L for mild steel TMTbars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 125 | M&L for two coat of synthetic enamel paint to new or previously untreated steel surface of any description, over 10cm in width or girth, not otherwise described over one coat of red oxide primerincluding preparation of surfaces as specified and directed. |
| 126 | Complete removal of the wild grass/ vegetation from surrounding area of OHTs, Tubewells/Booster and installations area and making the surface clear and plain and spraying roundup chemical on the same clean areaas directed after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as specified and directed.Note- All necessary T&P will be provided by the contractor and no extra amount shall be paid for that seperately. |
| 127 | Supply and installation with testing complete of digital water level indication device, operating on single phase supply direct display in(letter display) digit system in meter/CM of water of over head tank ensuring alarm while water fall or rise over predetermined limits with the following description complete all as specified and as directed by Engineer-in-charge including dismantling old unserviceable water level indicator.(a) The entire unit must operate through a compact electronic circuit which must ensure reliable operation at 230V + 10% at 50 Hz + 5%, with reliable in display and alarm at low and high level of over head tank.(b) One circuit must be housed in high impact polystyrene molded box with nylon molded connection strips.The level system must resistance transducer, while unattested by corrosion and othercontents available in water.The product must be controlled by Micro switch.(c) The whole unit must electronically controlled and the upper level and lower level indications must be in two parts. Each complete part must be fitted in MS CRS sheet box separately. One must be installed at over head tank and second at pump house with proper powder coating paint with locking arrangements |
| 128 | M & L forlaying, connecting & testing four/six core copper conductor flexible PVC insulated heavy duty unsheathed cable 1100 volts grade 1.0Sqmm from control box(water level sensor at RCC OHT) to display meter in pump room through ducts/under ground/ suitable protection pipes etc including taking out unserviceable flexible cable all as specified and as directed. |
| 129 | M&L for repair in leakages of 100 mm bore sluice valves by replacing Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required after dismantling ,refixing in existing position(inside the valve pit chamber of any type)including testingon completion complete all as specified and directed.Note: Quoted rates inclusive of the materialsmentioned above like Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required to arrest the leakages . |
| 130 | All as per item Ser No 105.00 above here-in-before but80 mm dia bore. |
| 131 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets , light fittings, etc taken on credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed. |
| 132 | Taking down carefully unservicable sub main wiring (4 Sqmm to 10 Sqmm size) including removal of batten/ conduit/ gutties/ wooden board etc and removal of unservicable items out of site complete all as specified and directed. Note: 2 runs of cable and one run earth wire will be measured as one length |
| 133 | Material & labour for point wiring complete with FRLS, PVC insulated unsheathed cable, 1100 volts grade confirming to IS-694, ISI marked, 1.5 Sq mm (nominal area) single core with copper conductor for phase and neutral, multistranded drawn through and including non metalic rigid PVC conduit of 20 mm dia and conduit accessories concealed in walls, floors, roofs etc, completeterminal box flush in wall withcover plate of required for mounting switches, socket, fan regulator etc includingprovisioning of FRLS, PVC insulated un-sheathed 1100 volts grade, ISI Marked, 1.5 sq mm solid / multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for the following. |
| 134 | One light / fan / bell point controlled by one switch |
| 135 | One 3 pin 5 Amps socket out let on independent board. |
| 136 | One 3 pin 5 Amps socket outlet on same board with other switches. |
| 137 | M&L for point wring ,using approved colour coding (Phase-red, Neutral-black, Earth-green) complete for one socket outlet 5 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 in existing conduit including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed . |
| 138 | S&F switch piano flush button single pole two way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed. |
| 139 | S&Ffor socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI markedcomplete all as specified and directed. |
| 140 | S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old one complete all as specified and directed. |
| 141 | S&Ffor socket outlet, 3 Pin, 5/15 Amp flush type conforming to IS 1293 ISI marked including taking down old one complete all as specified and directed. |
| 142 | S&F ceiling rose, surface Bakelite, isolated bodythree terminals complete all as specified and directed. |
| 143 | S&F Electronic fan regulator steped type(flush type) 240 volt ,50Hz,single phase on existing phenotic laminated sheetone and connecting unserviceable including taking down old unserviceable complete all as specified and directed. |
| 144 | S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm with standard accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down old oneNote: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit. |
| 145 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 146 | Supply and fixing LED light fitting2 feet, 10W,220 V ACdecorative type with driver holder ampincluding connecting up with three core flexiblecopper conductor cable of suitable size complete. |
| 147 | S & F LED light fitting 9W/10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 148 | Material & Labour for fixing Isolator 40 Amp Triple pole , 415 volts, 36KA,type including necessary connection all as specifed and directed. |
| 149 | S&F MCB TPN 63 Amp,C curve, 415 Volts, 50 Hz suitable for existing type and connectionwith copper lugs including taking down old unserviceable complete all as specified and directed. |
| 150 | S&F MCB TPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing type and connectionwith copper lugs including taking down old unserviceable complete all as specified and directed. |
| 151 | Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers.GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :-(a)GI wire of 4 mm dia.(b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm diamild steel TMT bars suitable for carrying of pit cover. |
| 152 | Disconnecting & taking out the existingdefective Oil immersed star delta starter of any description, any capacity and in any position, 3 phase,415 volts, 50 Hz suitable for AC supply submersible/centrifugal pump set upto 15 HP capacity and strip opening of Star delta starter, taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts, reassembling, fixing in position, making connections and testing complete, all as specified and directedNotes :-(i) Quooted rate shall also including of replacement of spare parts like fixed contact, moving contact,over load coil,no volt coil ,cam spring,lever spring,Transformer oil etc as requiredcharges of the parts replaced/repaired is deemed to be included in these item |
| 153 | M&L for cutting the existing GI pipe line 100mm dia and inserting Tee of size 100x100x50mm for making new branch conection of GI pipe of size 50mm dia including necessary fittings,excavation,returning and filling and depositing excavated material to a distance not exc 50m completeall as specified and as directad |
| 154 | M&L for cutting the existing GI pipe line 80mm dia and inserting Tee of size 80x80x50mm for making new branch conection of GI pipe of size 50mm dia including necessary fittings,excavation,returning and filling and depositing excavated material to a distance not exc 50m completeall as specified and as directad |
| 155 | S&FACP retro(3/4 mm thickness) sign board of size 1.2x0.6 meter using retro reflective high intensity prismatic reflective sheeting.The back ground of board is ib Blue colour with white border and writing letter,numbers white in colour mentioning the pump house details and MES logo.Retro signboard shall be pasted on 3mm thick ACP sheet.The board shall be fixed on wall including fixing of fastners,nuts,bolts,washer etccomplete all as specified and directed. |
| 156 | Isolate the water supply and empty the under ground water sump by using pumps of suitable capacity,after emptying the sump cutting/opening the existing rusted/damaged foot valve.S&Fnew foot valve of size 100mm bore,flanged/threaded type,IS:4038,PN 0.2 with strainer of cast iron IS 210 Gr FG200 and joining with existing suction pipe line including all connection items like nuts,bolts,washers,flanges etc complete all as specified and directedd. |
| 157 | S&F in repair MCCB 125 Amps adjustable type 16 KA, 3 pole, 415 voltfor pumphouse LT panel complete all as specified and directed. |
| 158 | S&F in repair MCCB 100 Amps adjustable type 16 KA, 3 pole, 415 voltfor pumphouse LT panel complete all as specified and directed. |
| 159 | S&F in repair MCCB 63 Amps adjustable type 16 KA, 3 pole, 415 voltfor pumphouse LT panel complete all as specified and directed. |
| 160 | Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc. all as directed by Engineer in charge |
| 161 | M&L for Non-skid ceramic tiles 7 to 8 mm thick(squre/rectangular)area of each tile exceeding .06 sqm but exceeding 0.11sqm,in floors etc.set and joined in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick CM1:4 for laying flooe finishes complete all as specified and directed. |
| 162 | Taking down cement/lime plaster of any description on brick work or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 163 | M&L for rendering 15mm thick in cement mortar 1:6 on brick/concrete surfaces finished even & smooth without using extra cement etc complete all as specified and directed. |
| 164 | Taking out or downdefectivesluice valve from main line andopening carefully old defective sluice valve 80mm bore and in any position for and including servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the sluice valve after repair and refixing the same & testing after installation complete, all as specified and directed.Note :- (i)The cost of Earth work, joints & jointing materials washers, gaskets and minor parts shall be deemed to be included in the quoted rates(iii) Replacement of the defective parts i.e. cast iron gate & stainless steel spindle of Sluice valve shall also be included in thequoted rate. |
| 165 | Supply and fixing LT panel board indoor type, cubical compartmentpedestal mounting type fabricated CRCA sheet of 2.00 mm thick with both side open type, suitable for 3 phase 4 wire system, 415 volt with insulted Copper bus bar of size suitable to carry 1.5 times current of main MCCB incomershould be provided to length/width of the panel for free and smooth connection of the cable for MCCB, finished with powder coated, dust vermin proof, ventilated compartment door and necessary including arrangement for fixing on wall indoor with the following itemsincluding connection with suitable capacity of copper wire for internal wiring and connecting to LT UG cable using suitable size of lugs and testing and commissioning with foundation, including taking out the old U/S panel board from position and removing from site and make all electrical connection with existing outgoing/incoming cableto the new panel with suitable size lugs complete all as directed:-Incoming:a)MCCB 125 Amps ,25 kA, TPN415 Volt ,Thermally adjustable - 02Nos( 1 Nos Spare )b) Copper Bus bar chamber strip size mmsuitable for 250 Amps including insulator , hylem sheet , cable connection etcc) Indicator lamp LED type (RYB) –01 Set. Make- Seimensd) Volt meter Digital type 0-500V with selector switch. One set.e) Amps meter Digital type 0-500 A with CT & selector switch. 01 No. One setOutgoing:a)MCCB 63 Amps ,25 kA, TPN415 Volt ,Thermally adjustable - 02Nos (1 nos Spare)b) star delta starter suitable for 15 HP motors -02 Nos (1 Nos spare)\"c)MCCB TPN 40 Amps -01 Nos\"d)All interconnections between the main bus bar as well as outgoing MCCB shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of outgoing individual MCCB\"Note :(i)Panel should be manufactured from CPRI approved firm only. (ii) Panel platform should be 1.5 ft hight from ground level (iii) conecting of existing UG cable as per site requirement\" |
| 166 | M&L for detection and rectification of leakages in refrigerant line bynitrogen gas to find outleakage inwindow / split type AC(1.5/2.0TR),water cooler/Deep freezer/Refrigerator of any model/make and ensuring the complete systems leak proof flushing out nitrogen gas including checking the system and charging/Topup of refrigerant gas R-134A / R 22/R-32 or any other refridgerant gas as requiredwith appropriate quantity including testing for smooth functioning and re-assembling and re-installation in same/other position complete all as specified and directed. |
| 167 | S&F in replacement Thermostat Switchas per exsisting size & model of Window/Split 1.5 TR/2.0 TR Capacityincluding taking out unserviceable Thermostat Switch from ACcomplete all as specified and as directed. |
| 168 | S&F in replacement of Thermostatsensor of AC (Window/Split Type) 1.5 /2.0 TRand removal ofunserviceable Thermostat sensor from AC complete all as specified and as directed. |
| 169 | S&F in repair ofPCB for indoor/Outdoor unit ofInverter Split AC of any type of capacity 1.5/2.0 TR including removal of old PCB complete all as specified and directed. |
| 170 | S&F in repair ofPCB forwindow AC 1.5/2.0 TRHot & Cold, Inverter ACs of any type and capacity including removal of old PCB complete all as specified and directed. |
| 171 | M&L for removing brunt wiring kitof window /spilt type ACs, water cooler replace with best qualitynew wiring kit suitable type of PVC insulated copper conductor cable including thimbles sleaves of suitable size & shape complete all as specified and directed. |
| 172 | S&F in repairof PVC blower of SplitType AC 1.5/2.0 TR Capacity of approved Make and required Size to suit existing AC incuding removal of unserviceable blower complete all asspecified and as directed. |
| 173 | All as per item No 145.00 above but forwindow AC ( 1.5/2.0TR) |
| 174 | M&L for dismantling of defective PCB of window/Split AC of1.5/2.0 TR capacity of any make & type andrefixingafter repairing the PCB to ensure proper functioning of the AC complete all as specified and directed. |
| 175 | Disconnectingelectric connection of Split/Window air conditioner ,watercooler/Deep freezer of any capacityfrom any height and taking down/ keep aside servicing the samecleaning inside, cleaning of fins by means of airblower and water with pressure jet , cleaning of air filter, remove dust from body, tightening of loose nut bolt, washer, rubber gasket,tightening of loose wiring, loose connection and repair of parts, wornout nutbolt, washers, gasket,valves,temperature sensor,swing motoretc and necessary cutting, welding/soldering works with replacement of rusted bodywith new MS/GI Sheets of suitable size and making the appliencefullyfunctionaland re-assembling and re-installation in same/other position and testing complete all as specified and directed. Note: (i) .All the repairs shall be carried out at MES store yard including transportation of equipment shall be contractor\"s own arrangment.(ii) All newparts will be measured and paid as supply only under the respective item. |
| 176 | Supply only in replacement of starting/running capacitor of 5 to 30 mfd capacity for compressor ofWindow/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and as directed. |
| 177 | Supply only in replacement of starting/running capacitor of 30 to 80mfdcapacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and as directed. |
| 178 | Supply only in replacement of starting/running capacitor upto 5mfd capacity for Fan motor ofWindow/Split Type Acs( 1.5 TR/2.0 TR) complete all as specified and as directed. |
| 179 | Supply only Swing motor suitable for 1.5 TR / 2 TRwindow/split type ACs of any type/model complete all as specified and directed. |
| 180 | Supply only temperature sensor for 1.5 TR / 2 TR window/split typeAC of any type complete all as specified and directed. |
| 181 | Supply onlyin replacement Air Filtersuitable of AC (Window/Split type)1.5 TR/2.0 TR Capacitycomplete all as specified and as directed. |
| 182 | Supply only brass suction/discharge valve of size 1/4 \",3/8\",1/2\", 5/8\"for 1.5TR/2.0TRof split AC/window AC complete all as specified and directedd |
| 183 | Supply only drain pipe of3 mtr length suitable for split type air conditioner of 1.5/2.0 TR of existing make complete all as specified and directed. |
| 184 | Supply only in replacement compressor shut off valve of suitable size for window/split ACup to 2.00 TRcapacitycomplete all as specified and directed. |
| 185 | Supply only remote hand set of window/split type air conditioner of capacity 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed. |
| 186 | Supply and fixing in repairof copper tubing 1/4\", 1/2\",3/8\" diacomplete all as specified and directed. |
| 187 | Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacityand supply & fixing new condensing unitcomplete with compressor,condensing coil, coil frame, wiring kit and running capacitor, relay,condensing motorwith blade complete all as specified and directed. |
| 188 | M&L in replacement of Starting Relay of AC(Window/Split Type) 1.0/1.5 TR/2.0TR Capacityincluding taking out unserviceable Relay from ACcomplete all as specified and as directed. |
| 189 | M&L for dismantling of unserviceable/worn out reciprocating/hermetically sealed unit compressorfrom Deepfreezer/Refrigeratorand replacement with new compressor, suitable for existing model/make including brazing with suction and discharge line, checking the system for leak proof and inclduingcharging of refrigerant gas R-134 A /R-32 or required type in appropriate qty after makingvaccum the complete systemand testingfor proper functioning complete all as specified and directed. |
| 190 | M&L in replacement of Strainer with Capillary tube/capillary tube of Window/ Split Type AC 1.5 /2.0TR Capacity including taking out unserviceableCapillary Tubefrom ACcomplete all as specified and as directed. |
| 191 | Supply and fixing ofPVC nylon imbraided pipe15 mm dia forcondensed waterdrain fitted on wallincluding all fittings complete all as specified and directed. |
| 192 | S&F in repair of foam insulation heavy duty for 1.5TR/2.0TR split ACs refrigerant line as per exsisting size complete all as specified and directed. |
| 193 | M&L for refrigerent gas charging (Top up)with required quantity of refrigerant R-22/R 32/R 407/R 410 or any other refrigerent as per the requirement in window & split ACs,water cooler,Deep freezer,Refrigerator of any capacity and make for its smooth functioning after carrying out vaccum and pressure test including necessary soldering/brazing to prevent leakage all as specified and directed. |
| 194 | Taking out defective condenser fan motor from window type AC (Hot and Cold ACs or any other type) of capacity 1.5/2.0 TRtransporting defective motor of any make & capacity from site at any height to contractor workshop dismantling the burnt winding & rewinding theblower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed. |
| 195 | All as per item No 167.00 above but for condenser fan motor of split AC (1.5/2.0TR) |
| 196 | All as per item No 167.00 above but for blower fan motor of split AC ( 1.5/2.0TR) |
| 197 | Dismantling of defective indoor unit of 1.5 TR capacity split typeAC (Hot and Cold ACs or any other type)and supply & fixing new indoor unit of the same capacitywith blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required all as specified and directed. |
| 198 | M&L for taking down of window/Split type AC of any capacity or model from any height/ any floor up to threestorey buildingand shifting to another locationin the sameor other building and refixing at New Location including testing of leakage and charging/top up of specified gasas per the make of the AC and make it fully functional again at new locationcomplete all as specified and directed. |
| 199 | S&F in repair of Cooling/Heatingcoil complete with fins made of copper suitable for Window type AC (1.5/2.0 TR) as per existing model/size including removing of old cooling coil complete all as specified and directed. |
| 200 | All as per item No 172.00 above but forsplit AC ( 1.5/2.0TR) |
| 201 | S&F in repair of condensing coil complete with fins made of copper suitable for Windowtype AC (1.5/2.0 TR) as per existing model/size (Hot and Cold ACs or any other model)including removing of old condencing coilcomplete all as specified and directed. |
| 202 | All as per item No 174.00 above but forsplit AC ( 1.5/2.0TR) |
| 203 | Taking down defectivecondenser fan motor of 1.5/2.0 TR Split AC S&F new condenser fan motor as per exsisting make/model with copper winding complete all asspecified and as directed. |
| 204 | Taking down defectivecondenser fan motorof 1.5/2.0 TR window AC S&F new condenser fan motor as per exsisting make/model with copper winding complete all asspecified and as directed. |
| 205 | Taking down defectivecondenser fanblade of 1.5/2.0 TR window/split AC S&F new condenser fanblade as per exsisting make/model with copper winding complete all asspecified and as directed. |
| 206 | S&F Sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one single pole MCB of\"C\" series of capacity 16-32 Ampincluding taking out the old one complete all as specified and directed. |
| 207 | M&L metal clad Industrial plug top ISI mark 2 pin with earth 250 Voltsincluding taking down old one complete all as specified and directed. |
| 208 | Supply and fixingMCB SP 16-32Amps rating of \"C\" seriesto be housed in industrial socket complete all as specified and directed. |
| 209 | M&L Metal clad Industrial socketISI mark with earth 250 Voltsincluding taking down old one complete all as specified and directed. |
| 210 | M&L for dismantling of unserviceable/worn out hermetically sealed unit compressorfrom windowACand replacement with new compressor, suitable for existing model/make (Hot and Cold ACs or any other model)of capacity 1.5/2 TRwindow type AC including brazing with suction and discharge line, checking the system for leak proof and inclduingcharging of refrigerant gas R-134 A /R 22 /R-32 in appropriate qty after makingvaccum the complete systemand testing the AC for proper functioning complete all as specified and directed. |
| 211 | All as per item No 183.00 above but forsplit AC ( 1.5/2.0TR) |
| 212 | S&Fofpartical board, 12 mm thick prelaminated,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished fixing in small pices around window AC to make air tighton wall/window including necessary carpenter work complete all as specified and directed. |
| 213 | S&F in repair of stand mounting bracket (heavy duty)for split AC (1.5/2.0TR) made of 2mm thick high steel power coating for rust prevention suitable for wall/floor mountedout door AC unit,including fixing with suitablefastenerson exsisting location/building (upto three storey) complete allas specified and as directed. |
| 214 | S&F reverse cycle solenoid valve in splittype AC 1.5 / 2 TR capacitywithnecessaryextension to suction/ discharge copper tubing & toggle switch complete all as specified and directed. |
| 215 | S&F 5 KVA wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5% completeand taking out old unserviceable stabilizer complete all as specified and directed. |
| 216 | S&F in repair of PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed. |
| 217 | S&F in repair of power transfromers suitable for voltage stablizers of capacity 4/5 KVAcomplete all as specified and directed |
| 218 | S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with 2 x single core FRLS PVC insulated and unshealthedstranded copper conductor cable 4 Sqmmas current carrying conductor and one run of 4.0 Sqmm as earth contunity conductor, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old one complete all as specified and directed.Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and PVC conduit shall be measured as one unit. |
| 219 | M&L for removing the desert cooler from its existing position at any height from stand or pillar, removing the side panels, taking out unsv wood wool pads or loose pads including supporting jali(HDPE plastic /steel wire mesh)and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) including one coat of black japan paint in side the base of tank tank after preparation of old painted surfaces and reassembling and fixing in positionincluding oiling and greasing of fan kit, water pump motor, refixing wood wool pad secured with new HDPE soft mesh complete all as specified and directed. |
| 220 | Taking down of unserviceabledetachable type perforated side panel from exsisting desert coller S&F new perforated side panel made out 22 gauge PGI sheetsuitable for desert cooler over all size of 0.750x0.750x0.910 mtrcomplete all as specified and directed. |
| 221 | S&F in replacement of unserviceable wood wool pads with supreme quality white wood wool (set of three) in repair includingPVCpipe pieces 03 Nos of required length & dia for connection of water distributor/ elbows of desert coolers of complete all as specified and directed. |
| 222 | Supply and fixing in replacement of supreme quality white wood woolin loose suitable for industrial desert coolercomplete all as specified and directed. |
| 223 | S&F in repair of switch piano flush button single pole one way 15 Amp, 240 Volts in desert cooler conforming to IS 3854 ISI marked. |
| 224 | Taking downunserviceableexhaust fan (heavy duty) of 16\"/18\"sweep size,2800 rpm from desert cooler, supply and fixing newexhaust fan (copper winding) of same capcity complete with fan blade ,fixing in the same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed.Note :- Old unserviceable exhaust fan shall be deposited in MES Store Yard. |
| 225 | Taking out defectiveexhaust fan of 16\"/18\"of any make from desert/industrial coolerand transporting it tocontactor\"s workshop, opening of fan motor , taking out rotor, cutting out the burnt winding ,cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, painting reassembling testing and fixing in position complete all as specified and directed.Note :- Old unserviceable exhaust fan shall be deposited in MES Store Yard. |
| 226 | Taking out defective desert cooler fan ofcapacity upto 300watt, 1500rpm capacity from desert coolerrewinding of the same with the existing size of super enameled copper winding including varnishing, greasing, painting reassembling testing and fixing in positioncomplete all as specified and directed. |
| 227 | Supply and laying orfixing or passingtwo core 4 sqmm stranded conductor laid throuth suitable size of PVC pipe on walll or floor, 1100voltsgrade heavydutycablewith PVCinsulated aluminiumconductor served with aninner sheathing of PVC tapearmouredwith galvanisedsteel wire or tapeandoverallPVC sheathed. |
| 228 | S&F in repair of Polycarbonate Plug top 3 pin 6/16 Amp of desert cooler/ACs complete all as specified and directed. |
| 229 | Supply and fixing in repair ofcopper conductor three core PVC insulated and sheathed cable size 1.50 sqmmISI mark for desert cooler complete all as specified and directed. |
| 230 | Supply and fixing in renewal of desert cooler submersible pump having power of 18/20W,and out put 1200 Ltr/hr single phase 230 Volt AC, (ISI marked) suitable for evaporating type desert cooler including fixing clamp inside the desert cooler complete all as specified and directed |
| 231 | Supply and fixing in renewal of desert coolersubmersible pumphaving power of 40W &3500 Ltr/Hr output, single phase 230 Volt AC, (ISI marked)suitable for Industrial type cooler including fixing clamp inside the Industrial type cooler complete all as specified and directed |
| 232 | Supply and fixing in repair ofsteel multi wing exhaust fan blade set of best quality as per existing type and size of16\"/18\" sweep heavy duty for desert cooler complete all as specified and directed. |
| 233 | Taking down unserviceable fresh air fan motor (Fan kit) from desert cooler and supply and fixing new fresh air fan kit of copper winding (150-300Watt),1500 RPM,230 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed. |
| 234 | Taking down unserviceable exhaust fan frame S&F fan frame and sppoting Leg for exhaust fan including nut, bolts, washer Rubber,clamp etc complete Set complete all as specified and directed. |
| 235 | S&F in repairof capacitor upto 4.5Mfd for desert cooler fancomplete all as specified and directed. |
| 236 | S&F of plywood 6mm thick, cut to shape as required on site fixing aroundwall/ window/ cooler opening with and including necessary nuts & bolts/ screws complete all as specified and directed. |
| 237 | M&L for removing of perished body of desert cooler over all size 0.750x0.750x0.910 mtr from existing site andreplace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximet 0.750x0.750x0.230mtr and front grillmade out of 26 gauge PGI sheet 0.460x 0.460mtr size for air flow direction,03 Nos perforated sheet side panels size Approximate 0.680x0.610mtr of each and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally including fixing the exiting fan kit & Pump motor received from old unserviceable Desert Cooler including all electrical connections, testing and commisioning complete all as specified and directed. |
| 238 | Taking out the unserviceable sealed compressor unit from water cooler andS&F New Sealed compressor unit of existing sample, suitablefor 40/80 Ltr &60/120 Ltr capacity of water cooler replace with newcompressor (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 ain appropriate quantity and testing for smooth functioning complete all as specified and directed. |
| 239 | Supply and fixing in replacementof evaporator coil ISI marked suitable for water cooler of any make/type/ capacity including all fixing accessories and making connection / detecting leakage and gas charging etc complete all as specified and directed by Engineer-in-Charge. |
| 240 | S&F in repairof starting/running capacitor upto 30Mfd for blower motor of water coolerhaving capacityof 40/80 & 60/120 ltrcomplete all as specified and directed. |
| 241 | S&F in repair of starting/ over load Relay for Water Cooler having capacity 40/80 and 60/120 Litres ofany make including removing unserviceable relay complete all as specified and directed. |
| 242 | S&F in repair of thermostat switch /relay suitalbe for water cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable onecomplete all as specified and directed. |
| 243 | S&F in repair of condenser coil(copper tubing) for Water Cooler having capacity 40/80 and 60/120 Litres ofany make including removing unserviceable condenser coil complete all as specified and directed. |
| 244 | Taking out the burnout blower motor from water cooler andS&F New single phaseblower motor (copper winding) of existing sample/size suitablefor 40/80 Ltr & 60/120 Ltr capacity of water cooler complete all as specified |
| 245 | S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. |
| 246 | S&F in replacement steel waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed. |
| 247 | Taking out defectivewater cooler blower motor any make/size fromcooler upto 60/120 ltr capacity , cutting out the burnt winding cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire includinggreasing, reassemblingcomplete all as specified and directed. |
| 248 | S&F in replacement of steel body desert cooler fan regulator of existing type and size including removing old regulatorcomplete all as specified and directed. |
| 249 | M&L for preparation of new plastered surface and applying two coats of OBD over a coat of primer complete all as specified and directed. |