| Sl. No. | Item Description |
| 1 | S&F modular Switch, one way, 10 Amp, single module complete all as specified and directed. |
| 2 | S&F Modular Switch, one way, and 20 Amp single module complete all as specified and directed. |
| 3 | S&F Modular Switch, two way, and 10 Amp single module complete all as specified and directed. |
| 4 | S&F Modular Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 2 module complete all as specified and directed. |
| 5 | S&F Modular Socket outlet multipurpose having provision for 3 pin, 16 Amp and 2 pin, 2 module complete all as specified and directed. |
| 6 | S&F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 7 | S&F for Bell push modular 10 Amps single module complete all as specified and directed. |
| 8 | S&F in replacement Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 9 | S&Flamp holder insulated body with back plate PVC/Polycarbonate type with cord grip cap, angular type fixed on wall complete all as specified and directed. |
| 10 | S&F Ceiling rose, surface Bakelite suitable ISImarkedcomplete all as specified and directed. |
| 11 | S&F switch socket combination with box 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed. |
| 12 | S&F switch socket combination with box 6/16 Amps flush mounted 3/5 pin multi purpose complete all as specified and directed. |
| 13 | Taking down carefully exising unserviceable point wiring of any type (light, fan, socket or power), complete with fitting such as switches, ceiling rose, pendent, regulators etc. for taking credit and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed. |
| 14 | M & L for Point wiring using approved colour coding as per IS, with multi-stranded copper conductor1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing capping including all accessories etc,heavy duty ISI marked, concealed / surface mounted as per site requirement with mild steel sunken boxes / PVC surface mountedbox with earth dolly duly, covered with laminated hylem sheet/ PVC cover, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multi-stranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following (Item no. 15 to 18):-(a) One light point controlled by one, one way switch 5 Amps. |
| 15 | (b). One fan point/ exhaust fan point controlled by one, one way switch 5 Amps |
| 16 | (c). One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 17 | (d). One bell point controlled by bell switch 5 Amps |
| 18 | (e). One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 19 | All as per item no. 14 above but using 2.5 sq mm single core copper conductor cable for 5/15 amps point including2.5 sq mm copper conductoras earth continuity conductor, complete all as specified and directed |
| 20 | M & L for Point wiring with colour coding as per IS, with multi-stranded copper conductor1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSH Cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cabledrawn through in and including heavy duty PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, including making good of disturbed surface and finish with two coats of white / colour washing / distempering etc to match the existing surface complete etc heavy duty ISI marked, with GI sunken boxes with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches including PVC insulated multi-stranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following (Item no.21 to 25) :-(a). One light point controlled by one, one way switch 5 Amps |
| 21 | (b). One fan point/ exhaust fan point controlled by one, one way switch 5 Amps |
| 22 | (c). One light point controlled by two way switches 5 Amps. |
| 23 | (d). One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 24 | (e). but One bell point controlled by bell switch 5 Amps. |
| 25 | (f). One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 26 | All as per item no. 20 above but using 2.5 sq mm single core copper conductor cable for 5/15 amps point including2.5 sq mm copper conductoras earth continuity conductor, complete all as specified and directed |
| 27 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 1x10 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessoriesISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of conduit, 4 runs of 10 sq mm stranded copper conductor cable and 01 run of 10 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 28 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessoriesISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of conduit, 4 runs of 6 sq mm stranded copper conductor cable and 01 run of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 29 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessoriesISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of conduit, 2 runs of 6 sq mm stranded copper conductor cable and 01 run of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 30 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 4 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 1x4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessoriesISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of conduit, 2 runs of 4 sq mm stranded copper conductor cable and 01 run of 4 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 31 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 04 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in walletc.and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of casing capping, 2 runs of 4 sq mm stranded copper conductor cable and 01 run of 4 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 32 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 6 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in walletc.and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of casing capping, 2 runs of 6 sq mm stranded copper conductor cable and 01 run of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 33 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 6 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, two single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in walletc.and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of casing capping, 4 runs of 6 sq mm stranded copper conductor cable and 02 runs of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 34 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of sizewith 10 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH confirmingto IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, two single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in walletc.and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed.Note:-One meter length of casing capping, 4 runs of 10 sq mm stranded copper conductor cable and 02 runs of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length. |
| 35 | Supply, installation, commissioning and testingof chemical earthing with 3 m long 25 mm pure copper hollow Earthing Rod with strip in pipe design and copper terminal 100x50x5, filling with high electrical conductivity and high moisture retaining capacity, hygroscopic, non magnetic and non corrosive in nature ROHS compliant BFC compound 50 kg, drilling bore to the depth of 3.5 mwith the help of Pneumatic boring machine and includingEarth pit cover of size 300x300x240 mm made out of Reinforced FRP, etc. complete all as specifiedand directed by Engr-in-charge.Note :1.The earthing result should not be less than 1 ohm and testing equipment shall be provided by contractor without any extra cost to the Department. |
| 36 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed. |
| 37 | M & L For fixing earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe with 4 sqmm GI Wire complete all as specified and directed. |
| 38 | S&F in repair, Metal plug and socket, 2 pin and earth plug and socket including with one 20 Amps MCB SP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed.Make- Legrand / ABB/L&T/ Schenider |
| 39 | S&F in repair, Metal plug and socket, 2 pin and earth plug and socket including with one 32 Amps MCB TP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed.Make- Legrand / ABB/L&T/ Schenider |
| 40 | S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, and MCB as outgoing with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:- MCCBs and MCBs will be measured and paid separately under respective BOQ.Make- Legrand / ABB/L&T/ Schenider |
| 41 | All as per item no 40 above but TP & N 8 way double door (VTPN MCCB DB), complete all as specified & directed. Make- Legrand / ABB/L&T/ Schenider |
| 42 | All as per item no 40 above but TP & N 12 way double door (VTPN MCCB DB), complete all as specified & directed. Make- Legrand / ABB/L&T/ Schenider |
| 43 | S&F in repairIP-43, protection metal double door Vertical TPN -DB rated bus bar, 415 volts, 50 HZ completewith interconnection links, blanking plates, cable ties, identification labelsTPN4 ROW of 10 modules suitable for accommodating up to 40 nos. SP/ TP/ TPN MCB as Incoming / outgoing and concealed /surface on wall as per site requirement including all cutting holes in or throughwalls, making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed.Make- Legrand / ABB/L&T/ Schenider |
| 44 | S&F in replacement MCB DB sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 100 amp rated bus bar, neutral & earthing link bar, flush / surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and S&F of new 04 way SPN DB (double door) and circuits complete as required at site making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed.Make- Havells / ABB/ L&T / Schenider |
| 45 | All as per item no 44 above but 08 way SPN DB (Double door), complete all as specified & directed. Make- Havells / ABB/ L&T / Schenider |
| 46 | All as per item no 44 above but 12 way SPN DB (Double door), complete all as specified & directed. Make- Havells / ABB/ L&T / Schenider |
| 47 | S&F in replacement MCCB with rating of 63-100 Amps, 415 Volts, 4 pole with 16kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity (Icu), MCCB should be with suitable spreaders and phase barriers for each terminals, complete all as specified & directed.Make- Havells / ABB/ L&T / Schenider |
| 48 | All as per item no 47 above but MCCB 125 Amps, 16 KA, 4 Pole,415V, complete all as specified & directed.Make- Havells / ABB/ L&T / Schenider |
| 49 | All as per item no 47 above but MCCB 160 Amps, 25 KA, 4 Pole,415V, complete all as specified & directed.Make- Havells / ABB/ L&T / Schenider |
| 50 | All as per item no 47 above but MCCB 200 Amps, 25 KA, 4 Pole,415V, complete all as specified & directed.Make- Havells / ABB/ L&T / Schenider |
| 51 | All as per item no 47 above but MCCB 250 Amps, 25 KA, 4 Pole,415V, complete all as specified & directed.Make- Havells / ABB/ L&T / Schenider |
| 52 | S&F in replacement MCB SP 6-32 Amps,10KA,\"C\" series complete all as specified and as directed.Make- Havells / ABB/ L&T / Schenider |
| 53 | S&F in replacement MCB SPN 20-40 Amps, 10KA, 240V, \"C\" series complete all as specified and as directed.Make- Havells / ABB/ L&T / Schenider |
| 54 | S&F in replacementMCB TP 40/63 Amps ,10 KA, 415 V, \"C\" series complete all as specified and as directed.Make- Havells / ABB/ L&T / Schenider |
| 55 | S&F in replacementMCB TPN 40/63 Amps ,10 KA, 415V, \"C\" series complete all as specified and as directed.Make- Havells / ABB/ L&T / Schenider |
| 56 | S&F in replacementRCCB 40 Amps, 100mA, 2 Pole, 240V, complete all as specified and as directed.Make- Havells / ABB/ L&T / Schenider |
| 57 | S&F in replacement plastic body fresh air fan 250mm sweep complete all as specified and as directed.Make :- Bajaj / cromptan / Havells /UshaNote: Old fan will be deposited in MES store yard. |
| 58 | S&F high speed pedastal fan of 400mm sweep complete all as specified and directed.Make :- Bajaj / cromptan / Havells /UshaNote: Old fan will be deposited in MES store yard. |
| 59 | S&F in replacement high speed wall mounted fan of sweep 400 mm, Full copper motor, auto thermal overload protection, compact style and powder coated guards & pull cord switch for speed regulation and oscillation control including connecting up the power cord to the socket and necessary fixing accessories, complete all as specified and as directed.Make :- Bajaj / cromptan / Havells /Usha / PolycabNote: Old fan will be deposited in MES store yard. |
| 60 | S&F in replacement white cover plate with frame 1 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 61 | S&F in replacement white cover plate with frame 2 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 62 | S&F in replacement white cover plate with frame 3 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 63 | S&F in replacement white cover plate with frame 4 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 64 | S&F in replacement white cover plate with frame 6 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 65 | S&F in replacement white cover plate with frame 8 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 66 | S&F in replacement white cover plate with frame 12 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 67 | S&F in replacement PVC unbreakable surface boxes suitable for modular switches 1 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 68 | S&F in replacement PVC unbreakable surface boxes suitable for modular switches 2 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 69 | S&F in replacement PVC unbreakable surface boxes suitable for modular switches 3 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 70 | S&F in replacement PVC unbreakable surface boxes suitable for modular switches 4 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 71 | S&F in replacement PVC unbreakable surface boxes suitable for modular switches 6 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 72 | S&F in replacement PVC unbreakable surface boxes suitable for modular switches 8 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 73 | S&F in replacement PVC unbreakable surface boxes suitable for modular switches 12 module, complete all as specified and as directed.Make:- As per the sample held with AGE office. |
| 74 | Supply only bearing No.6201/6202/6203 or any other No. matching to the existing size and suitable for ceiling fan / exhaust fan / wall mounted fan, complete all as directed by Engr-in-charge.Make:- SKF or equivalent make. |
| 75 | Supply only capacitor of 2.5 mfd suitable for ceiling fan / exhaust fan, complete all as directed by Engr-in-charge.Make:- Tibcon/Epcos/Havells |
| 76 | Supply only capacitor of 1.5 mfd suitable for ceiling fan / exhaust fan, complete all as directed by Engr-in-charge.Make:- Tibcon/Epcos/Havells |
| 77 | M&L for replacement of burnt winding of Ceiling fan 1200/1400mm sweep, working on 230 volts AC supply and re-winding complete with super enamelled copper wire of same gauge and weight, replacement of insulation paper, varnishing, heating up and testing complete including taking down and re-fixing the fan at its original position, complete all as directed by Engr-in-charge. |
| 78 | Al as per item no. 77 above but Exhaust fan upto 250/300/450 mm sweep working on 230 volts AC supply, complete all as directed by Engr-in-charge. |
| 79 | All as per item no. 77 above but Wall mounting fan of any 230/450 mm size, working on 230 volts AC supply, complete all as directed by Engr-in-charge. |
| 80 | S&F in repairs of fan blade (set of 3) suitable for 1400 mm ceiling fan of existingmake complete all as specified and as directed. |
| 81 | S&F in repairs of fan blade (set of 3) suitable for 1200 mm ceiling fan of existingmake complete all as specified and as directed. |
| 82 | S&F in replacement stator motor suitable for light duty fresh air ventilation fan of any sweep (approx 200/250mm) and fixing as per existing arrangement, complete all as specified and directed. |
| 83 | Supply only Self adhesive PVC electrical Insulation tape 7 mtr long, ISI mark with superior quality complete all as specified and directed |
| 84 | Supply andFix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc. suitable for 1200/1400 mm sweep ceiling fan, complete all as specified and as directed. |
| 85 | S&F in replacementdown rod, 2 feet long suitable for 1200/1400 sweep ceiling fan, made out of GI pipe medium grade 15mm dia with fan clamps including drilling cutting threding etc complete all as directed. |
| 86 | All as per item no. 85 above but 3 ft long, complete all as directed. |
| 87 | All as per item no. 85 above but 4 ft long, complete all as directed. |
| 88 | S&F in replacement anchor bolt & nut of 8mm dia suitable for geyser for fixing on wall in a suitable way and making good the disturbed surfaces of walls as per existing complete all as directed by Engr-in-Charge |
| 89 | S&F in replacement heating element 2 KW, 230 volt round/ triangular in shape, ISI marked, complete all as specified and as directed. |
| 90 | S&F in replacement Indicating lamp (red/green/yellow) complete suitable for geyser of any capacity complete all as specified and as directed. |
| 91 | S&F in replacement thermostat and cut out set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 ltrs capacity, complete all as specified and as directed. |
| 92 | S&F in replacement GI mesh hot water connection 600/900 mm long including necessary washers suitable for geysers of various capacities complete all as specified and directed. |
| 93 | S&F in replacement of Non-Return valve (NRV) of size 15mm dia, made out of Brass and suitable for any type of geysers complete all as specified and directed |
| 94 | S&F in replacement PVC insulated cable 2 core stranded copper conductor 0.5 sqmm complete all as specified and as directed. |
| 95 | S&F in replacement PVC insulated cable 2 core stranded copper conductor 1 sqmm complete all as specified and as directed. |
| 96 | S&F in replacement PVC insulated cable 3 core stranded copper conductor 1.5 sqmm complete all as specified and as directed. |
| 97 | S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed. |
| 98 | S&F in repairs cable PVC insulated 3 core 4 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed. |
| 99 | S&F in repairs 16.0 Sqmm copper conductor cable, PVC insulated, single core with stranded copper conductor, 1100V grade complete all as specified and as directed |
| 100 | Supply & fix in replacement 15A plug top and connection complete all as specified and as directed. |
| 101 | S&F in replacement plug top 3 pin, 5 amps, 230 volts, complete all as specified and as directed. |
| 102 | S & F in repairs LED indoor driver suitable for LEDfitting 10 to 35 Watts of the existing make including connection etc. complete all as specified and directed. |
| 103 | S & F in repairs LED indoor driver sutable for LED pannel recess mounted 2\"x2\" and 36 watts light of the existing make including connection complete all as specified and directed |
| 104 | S&F in replacement of recess mounted 2\"x2\" LED Panel lights with and including Light and its driver, 40 Watts, LED 5700K, 240 Volts and glare free symmetrical illumination suitable for Armstrong / Grid ceiling, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with and including twin core copper wire of suitable size and also matching to the adjacent ceiling surfaces carefully complete all as specified and directed Make:- LUKER CAT PART NO. LKM2240 or equivalent cat part in Havells / Phillips/ Bajaj/ Wipro |
| 105 | S&F in replacement recess mounted 2\" x 2\" LED Panel lights with and including Light and its driver, 40 Watts, LED color temperature 3000K-4000K, 240 Volts and glare free symmetrical illumination suitable for Armstrong / Grid ceiling, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with and including twin core, copper wire of suitable size and also matching to the adjacent ceiling surfaces carefully complete all as specified and directed. Make:- LUKER CAT PART NO. LKM2240 (WW) or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 106 | S&F in replacement of 20 watts, 230V, surface and wall mounted LED batten light fittings, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make- Luker LT520P or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 107 | S&F in replacement of 1x20 Watts, 230V, (warm white) LED batten light fittings suitable for indoor application of color temperature 3000K surface /wall mounted LED batten including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: Luker Cat part no LTM20 (WW) or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 108 | S&F in replacement of 1x20 Watts, 230 Volts, (3-in-1), LED batten light fittings suitable for indoor application of color temperature WH+NWH+WW surface /wall mounted LED batten including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: Luker Cat part no LT20 PR 3-in-1 or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 109 | S&F in replacement of 1x10watts, 230V surface and wall mounted LED batten light fittings suitable for mirror light with polycarbonate housing and integrated electronic driverincluding connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make- Luker LT510P or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 110 | S&F in replacement LED tube light with diffused optics ultra bright LED tube light 18/20watt with high efficiency suited for installation in existing T8 tube light with G13 lamp holderscomplete all as specified and directed by Engr-in-charge. Make: Havells/ Phillips/ Bajaj/ Luker/ Wipro |
| 111 | S&F in replacement of 1x18/20Watts, 230V surface and wall mounted batten suitable for installing LED Tube including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make- Havells/ Phillips/ Bajaj/ Luker/ Wipro |
| 112 | S&F in replacement of LED fixture, 30 watts surface mounted ceiling light 6500K with diffuser to give glare free light of size 300x300x35 mm, aluminium housing with compatible driver complete all as specified & directed.Make : Luker LNPRSRS30 or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 113 | Supply & fix LED recess mounting downlighter with ceiling cut out of 125 mm dia of wattage 9 watt 6500Kwith LED backlit round downlighter made of PDC AL with high efficient LEDs & glare free opal diffuser, IP20 including taking down existingcomplete all as specified and directed.Make- Luker LEPR09 or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 114 | S&F in replacement recess type LED ceiling lights 15 W LEDwith ceiling cut out of Ø 170 mm, 6000K recess mounted downlighter with separate replaceable electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed.Make: Luker LEPR15 or equivalent cat part in Havells/ Phillips/ Bajaj/ Wipro |
| 115 | S&F in replacement of recess mounted 2\" x 2\" LED panel lights 36 W LED 5700K, 240 Volts with integrated PIR sensor which offers autonomous operation and provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core copper wire of suitable size and also matching to the adjacent ceiling surfaces carefully with and including light and its driver etc. complete all as specified and directed. Make:- Havells CAT PART NO. VENUS NEOHE2X2R36WLED857PIRSENSOR or equivalent cat part in Phillips/ Bajaj/ Wipro |
| 116 | S&F smart switch with touch operation having controls for 3 x one way switch, 1 x fan regulator, 1 x 20 A switch complete all as specified and directed. |
| 117 | S&F smart switch with touch operation having controls for 6 x one way switch, 1 x 20 A switch complete all as specified and directed |
| 118 | Supply, installation, testing and commissioning in replacement of ceiling mount auto light occupancy, dual technology sensor, adjustable of delay timer, infra red and ultrasonic detection, Dia 8mm, IP 20, 3 wire with neutral optimum distance between 2 sensors should be 6.0 meter, stand by consumption 0.8 Watts, fixed directly to a false ceiling with including mounting claws or installed in a battibox depth 50 mm complete all as directed by Engr-in-Charge. Note:- (i).The cost of FRLSH copper wires of suitable size required for connection of lights of office bldg / OR living / Messes etc shall be deemed to be included in unit quoted rates. Make : Legrand Cat no 48806 or equivalent cat part in Havells / Bajaj / Orient. |
| 119 | S&F in replacement recess mounted 2\" x 2\" LED Clean room lights 36-42 W LED 5700K, 240Volts and glare free symmetrical illumination, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully with and including light & it\"s driver etc. complete all as specified and directed. |