| 1 | Excavation in trenches n.exc 1.50 mtr wide and n.exc 1.50 mtr in depth for foundation etcor for shafts , wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soilcomplete all as specified and directed. |
| 2 | All as per the description of srl item No 01 above but exceeding 1.5 m or part thereof in depth upto 3.0m |
| 3 | Demolition and breaking up drain pipes (salt glazed stone ware) set in cement for the following size:- |
| 4 | 150mm dia |
| 5 | 200mm dia |
| 6 | 300mm dia |
| 7 | M&L for cement concrete1:4:8 type D-2, (using 40mm graded crushed stone aggregate) in foundation, filling mass concrete and PCC bed for sewage pipe complete all as specified and directed. |
| 8 | S&F DWCPE (SN08) pipes snapefit coupler and rubber rings including testing and properly jointed laid in trenches to a level on plain bed for the following sizes complete all as specified and directed :- |
| 9 | 150mm internal dia |
| 10 | 200mm internal dia |
| 11 | 300mminternal dia |
| 12 | Cutting into existing manholes for connecting new pipes, making good to (150 to 300mm bore) pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 13 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan on exceeding 6m mean radius, using old size brick, built in cement mortar 1:4 including demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast articles, complete all as specified and directed. |
| 14 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan on exceeding 6m mean radius, using old size brick, built in cement mortar 1:4, complete all as specified and directed. |
| 15 | Taking down cement or cementplaster on brick walls/ceiling etc including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed. |
| 16 | M&L 15mm thick rendering in cement mortar 1:4 on faces of brick work or concrete external surfaces of wall finished even and smooth without using extra cement all as specified and directed. |
| 17 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as coping including weathering, slightly rounded, chamfered angles and finishing exposed surface even and smooth including necessary form work complete all as specified and directed. |
| 18 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc. 25cm complete all as specified and directed. |
| 19 | Removing excavated surplus soil to a distance exc. 1.50 km but n exc. 5 km and depositing where directed out of defence land complete all as specified and directed. |
| 20 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 21 | Precast cement concrete 1:2:4 type B-1 (20mm graded crushed stone aggregate) set in CM 1:4 as in cover slab (for manholes etc) landing, chullah hoods, chajjas andsimilar articles with plain faces, complete all as specified & directed . |
| 22 | M&L TMT bars 10mm dia and over, cut to length, bent to shape reqd, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 23 | S&F SFRC manhole covers and frame medium duty of overal size 900mm x 450mm x 80mm thick, factory made and test load 10 tonnes (MD-10), strength as per IS: 1726-1991 complete all as specified and directed. |
| 24 | Dismantling Old existing framed works such as grills, grating, manhole covers ,etc . |
| 25 | S&F MS framed work such as grills, gratings, manholes covers etc with ends of bars shouldered or reverted, frame work of water tanks and similar work conf to fe 410-0 or 310-0including applying one coat of red oxide complete all as specified and directed. |
| 26 | Demolition of cement concrete (unrienforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed. |
| 27 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate, as in surface channels and drainsincl necessary formwork complete all as specified and directed. |
| 28 | M&L for using mechinical means or manual method to clean the existing drain of any size or depth to clean such that free from any soil, dirt or building material including demolition of any existing foreign material, complete all as specified and directed. |
| 29 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. |
| 30 | Add or deduct for each 25mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. |
| 31 | S&F SFRC Manhole covers of 80mm thick and frame medium duty of overall area between 0.40 to 1.00 sqm each slab factory made and test load 10 tonnes (MD-10), strength as per IS : 1726-1991 complete all as specified and directed. |
| 32 | M&L PU Coated ROCKARD/MATTONS/OXFORD machine pressed precast rubber moulded coloured concrete interlocking paver blocks of 60mm thick any shape and size conforming to IS 15658-2006, M-35 grade laid over 40mm thick layer of sand cushioing and joints filled with sand complete all as specified and directed.Note:- Sand cushioning will be measured and paid separately. |
| 33 | Supplyonly 40mm thick sand filling under floors or in foundation including watering & consolidation etc complete all as specified and directed. |
| 34 | M&L 25mm thick Endura tac tiles, dense durable and abrasion resistant Tac liner metro yellow/Tac liner yellow or tack button terracota/Tac button yellow colour as approved by GE, (Square or rectangular) area of each tile exc 0.11 Sqm but n exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:4, completeall as specified and directed. |
| 35 | M&L PCC 1:3:6, type D2, using 40mm graded crushed stone aggregate avg 75mm thick as in sub floor, Sub base, floor complete all as specified & directed. |
| 36 | S&F in soft closing ball bearing telescopic channel of size 22 inch long fixed with screws in cupboards including all fittings complete all as specified & directed. Note:- Runner/ Channel should be SS 304 grade and load capacity should not be less than 45 kgs |
| 37 | S&F Modular Cabinet Kitchen accessoriesof Stainless Steelgrade-304,6mm size rod thicknessincluding :-(i) Perforated Cutlery basket, (ii) Grain trolley, (iii) Thali basket,(iv) Cup & saucer basket, (v) Glass basket,(vi) Plate basket, (vii) Premium magic corner(viii) Oil Pull out Tray ( Triple basket layer) of size as per site requirement complete all as specified & directed. |
| 38 | S&F 40mm dia and 75mm long, extrruded fancy type SS handle for kitchen cup boards shutters, cabinets, crocery shelf drawers fixed with nuts, screw and washer of mild steel bright finished, complete all as specified. |
| 39 | S&F 75mm long L Bihari concealed type hydrauilc hinges incl stainless screw complete all as specified & directed. |
| 40 | S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified. |
| 41 | Taking down/dismantling old particle board or any board kitchen cabinet with wardrobe including fillets and making good disturbed surfaces all assessary complete all as specified. |
| 42 | S&F 18/19mm thick factory made PVC moulded solid board one side pre-laminated for cabinet boxes, crockery almirahs, books shelves etc with self and shutter full size fitted under/above the kitchen cooking platform and other rooms directed including provn of fixing arrangement etc, complete all as specified and directed. |
| 43 | M&L for 100mm thick cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 44 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurrylaid over and including 15mm thick screed bed or bedding layers in CM 1:6 asin floors withpigment complete all as specified and directed. |
| 45 | M&L for painting new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 46 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 47 | S&F pre-painted galvalume aluminum zinc coating GI basedcorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 48 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 49 | S&F in repair 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 50 | M&L for 15mm bore GI tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc including, cutting chases in wall where ever required and then making good including dismantling of old GI tubing complete all as specified and directed. |
| 51 | M&L for laying of APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet of the membrane manufacturer with following specification etc complete all as specified and directed :-(a) removing and Cleaning existing damaged APP membrane from roof surface and clean all cement mortar and vegitation, plants with roots properly.(b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per litere at 25 degree centigrade on prepared surface.(c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch application with 10cm side laps and 15cm end lap over hot bitumen 85/25 grade @ 1.2 Kg/Sqm overbituminousprimer before Laying of membrane. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.(e)Top of membrane shall be provide with solar reflective bituminous aluminum paint as prescribed by manufacture of membrane. |
| 52 | M&L for brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 53 | M&L for 15mm thickin CM 1:4 on new surfaces of concrete or brick surfaces of walls or chajjas or pillars finished even and smooth without using extra cement including making provision/arrangement of scaffolding and necessary formwork if required as per site requirement complete all as specified and directed. |
| 54 | M&L for preparation of new plastered surface of wall and applying two coat of cement based paint over one coat of primer from the same manufacturer including making provision/arrangement of scaffolding if requiredas per site requirement complete all as specified and directed. |
| 55 | S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified |
| 56 | S&F powder coated of any colour aluminium door shutters, aluminium section weighing 0.55 kg/m incuding necessary joining cleats, glazing clips, ruber neoprene packing handles 2 Nos, tower bolt in each door shutter, hinges powder coated aluminum snap beading screws etc, complete all as specified. |
| 57 | S&F aluminium powder coated three track window (two shutters glazed & one shutters wire gauge) with frame, glazed with 4mm thick tinted glass and wire guage with stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below:-(a)Frame (top & side) section shall of size 92.00x31.75x1.50mm. (Section No 21447)(b)Frame (bottom) section shall of size 92.00x31.75x1.50mm. (Section No 21446)(c)Top & side members of shutter section shall be of size 18.00x40.00x1.50mm. (Section No 21455)(d)Interlock Section of Shutter shall be of size 18.00x40.00x1.50mm. (Section No 21454)(e)Bottom Members of shutter section shall be of size 18.00x40.00x1.50mm. (Section No 20844) |
| 58 | Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 59 | Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames) all as specified and directed. |