| 1 | Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed. |
| 2 | M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cableand one single core 1.5 Sqmm(nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :- |
| 3 | One light/fan/bell point controlled by one way switch 6 Amp complete all as specified and directed. |
| 4 | One light point controlled by two numbers, two way switch 6 Amp complete all as specified and directed. |
| 5 | One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed. |
| 6 | One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed. |
| 7 | All as per srl item No 2 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed. |
| 8 | S&F switch piano modular type, flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. |
| 9 | S&F switch piano modular type, flush type 15 Amp single pole one way, (ISI marked), complete all as specified and directed. |
| 10 | S&F socket outletmodular type, 3 pin, 5 Amp flush type universal, complete all as specified and directed. |
| 11 | S&F socket outletmodular type, 3 pin, 15 Amp flush type universal, complete all as specified and directed. |
| 12 | S&F modular step type fan regulators electronic type 120 watt, 2 module, complete all as specified and directed. |
| 13 | S&F modular cover plate with frame for 3 module, complete all as specified and directed. |
| 14 | S&F modular cover plate with frame for 4 module, complete all as specified and directed. |
| 15 | S&F modular cover plate with frame for 6 module, complete all as specified and directed. |
| 16 | S&F modular cover plate with frame for 8 module, complete all as specified and directed. |
| 17 | S&F modular metal flush box, 3 module, complete all as specified and directed. |
| 18 | S&F modular metal flush box, 4 module, complete all as specified and directed. |
| 19 | S&F modular metal flush box, 6 module, complete all as specified and directed. |
| 20 | S&F modular metal flush box, 8 module, complete all as specified and directed. |
| 21 | S&F switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. |
| 22 | S&Fswitch piano flush type 6 Amp two way, (ISI marked), complete all as specified and directed. |
| 23 | S&F switch piano flush type 15 Amp single pole one way, (ISI marked), complete all as specified and directed. |
| 24 | S&F socket outlet2 in 1, 3 pin, 6 Amp flush type universal, complete all as specified and directed. |
| 25 | S&F socket outlet2 in 1, 3 pin, 5A & 15 Amp flush type universal, complete all as specified and directed. |
| 26 | S&F ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed. |
| 27 | S&F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 28 | S&F switch piano bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified and directed. |
| 29 | S&F electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. |
| 31 | Supply and fixing in repair inverterLED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hourswith driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 32 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified and directed. |
| 33 | Supply and fixing in repair LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 34 | S & F in repair LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 35 | S&F in repair gate light fittings, outdoor type, high power , 25 watt, IP65 luminaire, prewired with suitable pole for mounting complete all as specified and directed. |
| 36 | S&F in repair PVC conduit non metallic rigid of size 25 mm dia (external) incl all accessories use forfixing of conduit on wall and ceiling etc complete all as specified and directed. |
| 37 | S&F in repair PVC casing caping of size 32 mm incl all fixing accessories complete all as specified and directed. |
| 38 | S&F in repair flexible PVC conduit of approved quality of size 25 mm incl all fixing accessories complete all as specified and directed. |
| 39 | S&F copper flexible twin twisted wire, PVC 10/0.2 gauge,complete all as specified and directed. |
| 40 | S&F flexible LED strip light with adapter water proof, multi colour suitable for 230 V, 50 Hz, complete all as specified and directed. |
| 41 | S&F Sub main wiring with single core cable 2x 4 Sqmm FRLSinsulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing capingmedium grade alongwith 1x 4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed.Note:-Three wire of 4 Sqmm and one run of pvc conduit/casing caping shall be measured as one unit. |
| 42 | S&F Sub main wiring with single core cable 2x 6 Sqmm FRLSinsulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing capingmedium grade alongwith 1x 6 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed.Note:-Three wire of 6 sqmm and one run of PVC conduit/casing caping shall be measured as one unit. |
| 43 | S&F in repair sheet metal enclosure for DBs, vertical TPN double door (IP43), 4 ways built in bus bars suitable for 415 volts, AC, 50 Hz and suitable for FP MCCB as incommer and out going SP/TP MCBscomplete all as specified and directed.Note:- MCBs shall be measured and paid separately. |
| 44 | S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 4 ways built in bus bars suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. |
| 45 | S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. |
| 46 | S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 12 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. |
| 47 | S&F in repair MCCB four pole 100 amps, 415 volts 25KA, complete all as specified and directed. |
| 48 | S&F in repair MCBTPN 63 amps 415 volts 25 KA \"C\" series, complete all as specified and directed. |
| 49 | S&F in repairMCBSPN 5 to 40 amps, C curve 240 volts 10 KA \"C\" series, finger proof terminal, bi-connect termination, label holder, 35 sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked, complete all as specified and directed. |
| 50 | S&F in repairMCBSP 5 to 40 amps, C curve 240 volts 10 KA \"C\" series, finger proof terminal, bi-connect termination, label holder, 35 sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked, complete all as specified and directed. |
| 51 | S&F in repairMCBisolator 63 amps, SPN C curve 240 volts 10 KA \"C\" series, finger proof terminal, bi-connect termination, label holder, 35 sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked, complete all as specified and directed. |
| 52 | S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed. |
| 53 | S&F in repair single pole and neutral enclosure with a two pin and metal earth plug and socket complete with & incl one single pole MCB of 20 Amps complete all as specified and directed. |
| 54 | S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core& including taking down old old unsv service cable connection, complete all as specified and directed. |
| 55 | S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core& including taking down old old unsv service cable connection, complete all as specified and directed. |
| 56 | S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 10 Sqmm 2 core including taking down existing old service connection, complete all as specified and directed. |
| 57 | S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 16 Sqmm 2 core including taking down existing old service connection, complete all as specified and directed. |
| 58 | Taking out of ceiling fan/exhaust fan/air circular fanand transport to the work shop, incl dismantling complete the ceiling fan parts, inspecting serviceability of all the parts, refixing of serviceable parts after cleaning and replacement of unserviceable parts with company\"s genuine parts i.e. capacitor, bearing, bushes, shaft, bracket, rubber bush, connecting wire,PVC connector, aluminium clamp for rod, bracket, bush rod, greasing/oiling etc assembling, cleaning and testing of ceiling fan complete all as specified and directed.Note: (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch \"A\" (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch \"A\".(iii)Cost of minor part i.e. Cotter pin, screws shall be deemed to included in the cost of quoted rate. |
| 59 | Ceiling fan (1200/1400 mm sweep) of any make |
| 60 | Exhaust fan (230/300 mm sweep) of any make |
| 61 | Supply only capacitor 4/2.5 mfd ISI marked complete all as specified and directed. |
| 62 | Supply only 3 core flexible copper conductor cable of 0.5 sqmm, complete all as specified and directed. |
| 63 | Supply only Gun metal bush for ceiling fan/exhaust fan of various sizes as required, complete all as specified and directed. |
| 64 | Supply only Fan blade for ceiling fan 1200/1400 mm sweep of existing make complete all as specified and directed. |
| 65 | Supply only brass bracket assy for hanging the ceiling fan 1200mm/1400mm sweep complete all as specified and directed. |
| 66 | Taking out old unsv exhaust fan from siteand replacement of exhaust fan made up of steel body, AC single phase, 230 V of size 300 mm sweep with blades and frame and louvers incl all connecting accessories complete all as specified and directed by Engineer-in-charge. |
| 67 | Supply and fixing in repair energy efficient LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver including suitable bracket fixed to wall/ pole complete with IP 65/66 protection complete all as specified and directed. |
| 68 | M&L for replacement of LED street light GI pipe bracket of dia 40 mm, 1.5 m length light grade and bent to required shape with 2 Nos MS clamp duly painted nuts and bolts, washers of suitable size of approved quality, complete all as specified and directed. |
| 69 | S&F LED lamp of 9 watt, complete all as specified and directed. |
| 70 | S&F LED lamp of 7 watt, complete all as specified and directed. |
| 71 | Taking out old u/s ceiling fan from site and replacement of new ceiling fan of capacity 1200 mm swee with3 blades,electric driven single phase 240 V, 50 Hz, 5 star rating BEE energy efficientincl all connecting accessories complete all as specified and directed. |
| 72 | M&L for Disconnecting electric & water connection to geyser of capacity 25/35/50 litr, taking down from existing position, dismantling and inspecting all the parts for its serviciability, cleaning of serviceable parts i.e.base assembly, connecting lead, thermostat, electric contact, electric wiring, indicators, safety valves etc re-fixing in the same in position, testing complete all as specified and directed by Engr-in-Charge. Notes: (i) The defective parts to be replaced shall be measured and paid separately under relevant item No. 57 to 69 of Sch \"A\"as supply only (ii) Cost of minor items i.e. screws, nuts, bolts etc shall be deemed to be included in this item |
| 73 | Supply and fixing in replacement heating element of capacity 2 KW, ISI marked suitable for existing size, type & make of geyser complete all as specified and as directed. |
| 74 | Supply and fixing in replacement heating element of capacity 1.5 KW, ISI marked suitable for existing size, type & make of geyser complete all as specified and as directed. |
| 75 | Supply only thermostat, ISI markedsuitable for existing size, type & make of geyser complete all as specified and as directed. |
| 76 | Supply only indicator lamp suitable for existing size, type & make of geyser complete all as specified and as directed. |
| 77 | Supply only geyser safety valve suitable for existing size, type & make of geyser complete all as specified and as directed. |
| 78 | Supply onlyPVC pipe connection of heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature complete all as specified and as directed. |
| 79 | Supply only inner tank made out of steel sheet conforming to IS, suitable for 25 litres capacity of geyser, vertical type complete all as specified and as directed. |
| 80 | Supply only inner tank made out of steel sheet conforming to IS, suitable for 35/50 litres capacity of geyser, vertical type complete all as specified and as directed. |
| 81 | Supply only on return valve made out of brass fixed in vertical position of suitable dia complete all as specified and as directed. |
| 82 | Supply only new base assembly with inlet and outlet pipe made out of steel sheet with gasket and proper size of nuts, bolts and washer etc suitable for 25 litres capacity of geyser complete all as specified and as directed. |
| 83 | Supply only new base assembly with inlet and outlet pipe made out of steel sheet with gasket and proper size of nuts, bolts and washer etc suitable for 35/50 litres capacity of geyser complete all as specified and as directed. |
| 84 | M&L for complete servicing and repair of Split type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position and testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items 57 to 68 of Sch |
| 85 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 2.0 T capacity complete all as specified and directed. |
| 86 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 1.5 T capacity complete all as specified and directed. |
| 87 | Supply only Fan/blower electric motor single phase 230 V complete for inner unit complete all as specified and directed. |
| 88 | Supply only Fan/blower electric motor single phase 230 V complete for outerunit complete all as specified and directed. |
| 89 | Supply only Starting capacitor of suitable capacity complete all as specified and directed. |
| 90 | Supply only Running capacitor of suitable capacity complete all as specified and directed. |
| 91 | Supply only Overload protection of suitable capacity complete all as specified and directed. |
| 92 | Supply only Drain pipe for Split unit PVC 20mm dia complete all as specified and directed. |
| 93 | Supply only Fan blade of suitable size for outer unit complete all as specified and directed. |
| 94 | Supply only Remote control kit complete for Split type AC complete all as specified and directed. |
| 95 | Supply only Condencing unit of Split type AC 1.5/2 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed. |
| 96 | Supply only Cooling unit complete suitable for 1.5/2 Ton Split type AC with complete accessories (Indoor type) complete all as specified and directed. |
| 97 | M&L for complete servicing and repair of Window type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing andcleaning of all accessories, oiling of fan motor, checking of wiring connections etc and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items |
| 98 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity complete all as specified and directed. |
| 99 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity complete all as specified and directed. |
| 100 | Supply only Capacitor of suitable capacity for Window AC 1.5/2 Ton capacity complete all as specified and directed. |
| 101 | Supply only Auto cut thermostate of suitable capacity for window AC 1.5/2 Ton complete all as specified and directed. |
| 102 | Supply only Overload protection for Window type AC 1.5/2 ton capacity complete all as specified and directed. |
| 103 | Supply only Grill for window AC of suitable size/shape /model as required at site complete all as specified and directed. |
| 104 | Supply only Fan blade of suitable size for window type AC unit complete all as specified and directed. |
| 105 | Supply only Fan/blower electric motor single phase 230 V complete all as specified and directed. |
| 106 | M&L for complete servicing and repair of Water Cooler any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch |
| 107 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 40/80 Ltrs complete all as specified and directed. |
| 108 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 60/120 Ltrs complete all as specified and directed. |
| 109 | Supply only Fan/blower electric motor single phase 230 V complet for water cooler 40/80 or 60/120 Ltrs capacity water cooler complete all as specified and directed. |
| 110 | Supply only Running capacitor of suitable capacity complete all as specified and directed. |
| 111 | Supply only Starting capacitor of suitable capacity complete all as specified and directed. |
| 112 | Supply only Auto cut thermostat switch for water cooler complete all as specified and directed. |
| 113 | Supply only Overload protector for water cooler of any capacity complete all as specified and directed. |
| 114 | Supply only Fan blade of suitable size complete all as specified and directed. |
| 115 | Supply only Push cock/soft closing tap brass chromium plated of size 15 mm complete all as specified and directed. |
| 116 | Supply only PVC connection pipe 600 mm long, both end screwedfor water cooler complete all as specified and directed. |
| 117 | Supply only Stop cock both end screwed chromium plated suitable for 15mm bore complete all as specified and directed. |
| 118 | Supply only ball valve PVC 15mm size for water cooler 40/80 ltr capacity complete all as specified and directed. |
| 119 | M&L for complete servicing and repair of refrigerator/deep freezer of any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge.Note:- Unsv accessories will be measured and paid seperately under respective items of Sch |
| 120 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 165 Ltrs capacity complete all as specified and directed. |
| 121 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 286/310 Ltrs capacity complete all as specified and directed. |
| 122 | Supply only Auto cut thermostate switch for Refrigerator defrosts type complete all as specified and directed. |
| 123 | Supply only Overload protectors for regrigerations upto 310 Ltrs capacity complete all as specified and directed. |
| 124 | Supply only Copper strainer filter for reftrigerator complete all as specified and directed. |
| 125 | Supply only Relays suitable for refrigerators upto 310 ltr capacity complete all as specified and directed. |
| 126 | Supply only Door switch for refrigerator complete all as specified and directed. |
| 127 | Supply only Door spring for refrigerator complete all as specified and directed. |
| 128 | Supply only Freezer chest door suitable for 286/310 Ltr capacity complete all as specified and directed. |
| 129 | Supply only Magnetised door lock rubber strip \"D\" type for regrigerator 286/310 Ltr cacpacity complete all as specified and directed. |
| 130 | Supply only Evaporator coil assembly 165 ltrs capacity regrigerator with copper pipe complete all as specified and directed. |
| 131 | Supply only Evaporator coil assembly 266/310 ltrs capacity regrigerator with copper pipe complete all as specified and directed. |
| 132 | Supply only Fan motor for chiller unit as per existing make complete all as specified and directed. |
| 133 | Supply and filling gas charging required to the System of suitable type R-34/12/32 /R22 or as per existing at site complete all as specified and directed. |
| 134 | Supply and filling gas charging required to the System of suitable type 134a or as per existing at site complete all as specified and directed. |
| 135 | S&F in repair base tray of window type AC 1.5/2 Ton capacity unit complete all as specified and directed including the following:-(a) Removing of compressor condenser, wiring kit, from base tray(b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted.(c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch |
| 136 | S&F in repair base of water cooler of any capacity unit complete all as specified and directed including the following:- (a) Removing of compressor condenser, wiring kit, from base tray(b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. (c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch \"A\" |
| 137 | Supply and fixing in repair PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 2.5 Sqmm complete all as specified and directed. |
| 138 | Supply and fixing in repair PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 4.00 Sqmm complete all as specified and directed. |
| 139 | Supply and fix in repair capillary copper tube for window , split, water cooler, refrigerator complete all as specified and directed. |
| 140 | Taking down of split AC 1.5/2 T capacity from existing location to refixing in another location incl both inner and outer units (filling up gas if necessary ) incl connected accessories in complete all as specified and directed by Engr-in-Charge. |
| 141 | S&F in repair plug top 3 pin 15 amps ISI marked complete all as specified and directed. |