| 1 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting holder etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conitions separately) and making good distrubed surfaces of walls, floors etc., complete all as specified and directed by Engr-in-charge.Note :Rate for dismantling for Srl Item No. 4.00 to 9.00 included in this item. |
| 2 | Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm widthwith MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface, complete all as specified and directed by Engr-in-charge. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. |
| 3 | One light point controlled by one, one way switch, complete all as specified and directed by Engr-in-charge. |
| 4 | One 3 pin 5 amp socket out point on the same board with other switches, complete all as specified and directed by Engr-in-charge. |
| 5 | One 3 pin 5 amps socket out let point on independent board, complete all as specified and directed by Engr-in-charge. |
| 6 | All as per same in item No 2.00 above but for one socket outlet 15 amp on independent boardwith2.5Sq.mmcableand1.5Sq.mm.earthwire, complete all as specified and directed by Engr-in-charge. |
| 7 | S &F in repair Switch piano flushtype single pole one way 5 amps, complete all as specified and directed by Engr-in-charge. |
| 8 | S&F in repair bell push switch fiush type 5 amp, complete all as specified and directed by Engr-in-charge. |
| 9 | S &F in repair Socket out let 2 in one, 5/3 pin 5 Amp, complete all as specified and directed by Engr-in-charge. |
| 10 | S &F in repair Switch socket combination 5 Amps 5 pin flush type, complete all as specified and directed by Engr-in-charge. |
| 11 | S &F in repair Switch socket combination 5 in 1, 5 pin5/15 Amps flush type universal, complete all as specified and directed by Engr-in-charge. |
| 12 | S &F in repair Ceilingrose, surface bakelite 65x50 mm three terminal, complete all as specified and directed by Engr-in-charge. |
| 13 | S&F in repair BELL ding dong AC 230 volt single pole, complete all as specified and directed by Engr-in-charge. |
| 14 | S & F in repair Lamp holder, PVC/Polycarbonate type insulated body with back plate for angle holder suitable for fixing of LED Bulbs of any wattage 230 Volts, complete all as specified and directed by Engr-in-charge. |
| 15 | M & Lin repair MODULAR(GANG BOX) Switch socket outlet 3 pin 5 amp\" flush type, complete all as specified and directed by Engr-in-charge. |
| 16 | M & L in repair MODULAR(GANG BOX) Switch socket outlet 3 pin, 15 amp, flush type, complete all as specified and directed by Engr-in-charge. |
| 17 | S &Fin repair for LED bulb/lamp of9 Watts Cool Daylight, complete all as specified and directed by Engr-in-charge. |
| 18 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engr-in-charge. |
| 19 | Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed by Engr-in-charge. |
| 20 | S & F in repair Ultra bright glass 20W LED tubelight (LT8-20-865-2)with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders as crystal glass LED Tubelight (Double Side Connection), complete all as specified and directed by Engr-in-charge. |
| 21 | Taking down old and UNSV DBs SPN/TPN complete with MCB TPN/SPN/SP, complete all as specified and directed by Engr-in-charge. |
| 22 | S&F in repair MCB DB 8 Way Sheet metal enclosure factory made for DBs single pole and neutral double door 240 voltswith 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed. |
| 23 | S&F MCB,DP 415 Volts , 40-63 Amps, complete all as specified and directed by Engr-in-charge. |
| 24 | S&F MCB SPN, 240 Volts , 32-40 Amps, complete all as specified and directed by Engr-in-charge. |
| 25 | S&F MCB, TPN, 415 Volts , 63 Amps, complete all as specified and directed by Engr-in-charge. |
| 26 | S&F MCB singal pole 240 Volts , 6 to 32 Amps, complete all as specified and directed by Engr-in-charge. |
| 27 | Supply and Fixing in replacment of Aluminum service cable PVC insulated and PVC sheathed of size 10 Sqmm two core as per IS:694 complete of appropriate length, complete all as specified and directed by Engr-in-charge. |
| 28 | Supply and fix in repair wall light decorative type 12w led Light, complete all as specified and directed by Engr-in-charge. |
| 29 | Taking down geyser storage type of capacity 50 Liters and dismantling the complete accessories cleaning of inner copper tank outlet/inlet tubes reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Taking down geyser storage type of capacity 25 Liters and dismantling the complete accessories cleaning of inner copper tank outlet/inlet tubes reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L in replacement solar geysers heating element 3 KW 240 Volt, complete all as specified and directed by Engineer-in-Charge. |
| 32 | M&L in replacement geysers heating element 2KW 240 Volt, complete all as specified and directed by Engineer-in-Charge. |
| 33 | M&L in replacement geysers heating element 1.5KW 240Volt, complete all as specified and directed by Engineer-in-Charge. |
| 34 | M&L in replacement geysers heating element suitable for 25 litre geyser incl thermostate coil type and cutout switch 240Volt, complete all as specified and directed by Engineer-in-Charge. |
| 35 | M&L in replacement geysers heating element suitable for 50 litre geyser incl thermostate coil type and cutout switch 240Volt, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and fixed in replacement single pole and neutral enclosure with three plug pin and socket complete with one single pole MCB SP 20Amps 10KA 220 Volt 50Hz, complete all as specified and directed by Engineer-in-Charge. |
| 37 | M&L for replacement thermostat switch for geysers with temperature range 25 degree centigrade to 85 degree centigrade, complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L in replacement of copper chromium plated connection 18\" long with two brass adopter heavy duty ISI marked & connecting, complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L in replacement of inner storage tank for geysers of 50 Liters capacity, complete all as specified and directed by Engineer-in-Charge. |
| 40 | M&L in replacement of inner storage tank for geysers of 25 Liters capacity, complete all as specified and directed by Engineer-in-Charge. |
| 41 | M&L in repair outer cover for geyser 50 liter capacity complete incl bottom cover plate and all connected items, complete all as specified and directed by Engineer-in-Charge. |
| 42 | M&L in repair outer cover for geyser 25 liter capacity complete incl bottom cover plate and all connected items, complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L in repair glass wool for geyser of capacity 25/50 litre, complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L in repair for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/recessed as required 2x4.0 sq. mm 1x2.5 sq. mm earth wire, complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L in repair for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/recessed as required 2x6.0 sq. mm 1x4 sq. mm earth wire complete all as specified and directed. |
| 46 | Repair/ replacement of exhaust fan of size 230 mm incl re- winding, greasing & replacemnt of beraing, complete all as specified and directed by Engineer-in-Charge. |
| 47 | Repair/ replacement of exhaust fan of size 450 mm incl re- winding, greasing & replacemnt of beraing, complete all as specified and directed by Engineer-in-Charge. |