}

Tender For Electric Work In Nagar Parishad Kekri Area (Arc) , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipa, Ajmer-Rajasthan

Department Of Local Bodies has published Tender For Electric Work In Nagar Parishad Kekri Area (Arc) , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipa. Submission Date for this Tender is 05-05-2025. Street Lighting Tenders in Ajmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

48841803
Tender For Electric Work In Nagar Parishad Kekri Area (Arc) , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipa
Open Tender
NCB
Rajasthan
Ajmer
05-05-2025

Tender Documents

Tender Details

Tender For Electric Work In Nagar Parishad Kekri Area (Arc) , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) <10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current <750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/ Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .Led Street Light Fixture With Minimum Lumen Outputlumen Output 3700 Lm , Lumen Output 5600 Lm , Lumen Output 8700 Lm , Supply And Fixing Of Lt Porcelain Shackle Insulator As Per Is:1443 1979 And As Per Discoms Standard Specifications, Suitable For Working Voltage 1100 Volts Including All Accessories Like Gi Hardware Fittings Confirming To Is:7935/1975 (Latest Amended) Nut, Bolt Etc. As Required. All As Per Pre Approved By Engineer Incharge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 75Mm X 90Mm , Supplying And Drawing Of Xlpe Insulated Lt Aerial Bunched Aluminium Conductor Cable Confirming To Is 14255/1995 And Is 398 (Pt-4)/ 1994 And As Per Discom Specs. On Existing Cross Arms Through I Hook With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 1 X 25 Sq. Mm. + 1X25 Sq. Mm. (Insulated) , Supply And Fixing Of Following Lt Supporting Accessories With Nut Bolt & Clamps Made Out As Per Standard Discoms Specifications With Two Coats Of Red Oxide And Two Coats Of Aluminium Paint Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Lt Cross Arm 600 Mm Long With Clamp , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 3 X 2.5 Sq.Mm , 4 X 2.5 Sq.Mm , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr . Single Pole Mcb (With B/C Curve Tripping Characteristics) 6A-32A Rating , Four Pole Mcb (With B/C Curve Tripping Characteristics) 50/63 A Rating , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 3 Pole Power Contactors With Following Ac 3 Rating 80 Amp , Sitc Of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 3 Pole Mccb With Thermal Magnetic Release Up To 100 Amp , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . One Day & Week Reserve (Digital Type ) , P & F Of Ip 55 Protected Light Controlled Switch Based On Infrared Sensing And Daylight With Built In Over Load Protection, Timer To Switch Off At Preselected Time. Switch Shall Have 7 Day Power Backup Without Hampering Of Preset Time And Over Ride Facility For Maintenance Purpose Suitable For 15 Kw Load (Three Phase) Including Contactor, Mcb, Cable Glands, Terminal Block And Locking Arrangement Gr-I (On Ruidp Bsr-2017) , Providing And Fixing Of Street Light Bracket Made Out From Following Size Of B Class, Medium Class G.I. Pipe Confirming To Is:1239 P-1 (2004) With Heavy Duty Pole Clamp, Saddles Suitable Fasterns Etc. As Required. All As Per Pre Approved By Engineer-In-Charge, For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr 32 Mm Dia , Providing And Fixing Of Street Light Bracket Made Out From Following Size Of B Class, Medium Class G.I. Pipe Confirming To Is:1239 P-1 (2004) With Heavy Duty Pole Clamp, Saddles Suitable Fasterns Etc. As Required. All As Per Pre Approved By Engineer-In-Charge, For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr 40 Mm Dia

Key Value

Document Fees
INR 1000 /-
EMD
INR 99800.0 /-
Tender Value
INR 49.90 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail