}

Tender For Miscellaneous Works For Upgrading Of Fire Fighting Systems And Smoke Detectors At Various Electricity Transformer Repair Workshoop In Distt- Meerut, Hapur, Baghpat, Muzaffarnagar, Shamli & Saharanpur Under Pvvnl, Meerut. - Earth Work In Excavat, meerut-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Tender For Miscellaneous Works For Upgrading Of Fire Fighting Systems And Smoke Detectors At Various Electricity Transformer Repair Workshoop In Distt- Meerut, Hapur, Baghpat, Muzaffarnagar, Shamli & Saharanpur Under Pvvnl, Meerut. - Earth Work In Excavat. Submission Date for this Tender is 08-05-2025. Vehicle Hiring Service Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48834908
Tender For Miscellaneous Works For Upgrading Of Fire Fighting Systems And Smoke Detectors At Various Electricity Transformer Repair Workshoop In Distt- Meerut, Hapur, Baghpat, Muzaffarnagar, Shamli & Saharanpur Under Pvvnl, Meerut. - Earth Work In Excavat
Open Tender
Indian
Uttar Pradesh
Meerut
08-05-2025

Tender Documents

Tender Details

Miscellaneous works for Upgrading of Fire Fighting Systems and Smoke detectors at various Electricity Transformer repair workshoop in Distt- Meerut, Hapur, Baghpat, Muzaffarnagar, Shamli & Saharanpur under PVVNL, Meerut. - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.DSR (2.8.1) 2 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR (2.32) 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) DSR (4.1.10) 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR (4.1.2) 5 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. DSR (4.12) 6 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)DSR (5.1.2) 7 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).DSR (5.2.2) 8 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR (5.3) 9 Centering and shuttering including strutting, propping etc. and removal of form for- Foundations, footings, bases of columns, etc. for mass concrete DSR (5.9.1) 10 Centering and shuttering including strutting, propping etc. and removal of form for- Suspended floors, roofs, landings, balconies and access platform DSR (5.9.3) 11 Centering and shuttering including strutting, propping etc. and removal of form for- Lintels, beams, plinth beams, girders, bressumers and cantilevers DSR (5.9.5) 12 Centering and shuttering including strutting, propping etc. and removal of form for- Columns, Pillars, Piers, Abutments, Posts and Struts. DSR (5.9.6) 13 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR (5.12) 14 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.- Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR (5.22.6) 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.- Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR (5.22A.6) 16 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). DSR (5.23) 17 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. DSR (5.30) 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) DSR (6.1.2) 19 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) DSR (6.4.2) 20 Brick work in foundation & plinth with old dismantledbricks (supplied by department free of cost) and coarse sandmortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete.(NSI), Ref. CSI No. (6.18) SOR 23-24 21 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR (10.2) 22 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.- Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). DSR (10.13.1) 23 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes DSR (10.30.1) 24 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.- 40 mm thick with 20 mm nominal size stone aggregate DSR (11.3.1) 25 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. DSR (11.5) 26 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes- 110 mm diameter DSR (12.41.2) 27 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. DSR (12.44) 28 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified- 2 mm thick corrugated (2.5 or 4.2 or 6) or step-down (2 or 3 or 6 ) as specified DSR (12.47.1) 29 Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately) - 0.71 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. DSR (12.65.2) 30 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Precoated/mill finish aluminium Ridges plain (500- 600mm) DSR (12.66.1) 31 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Precoated/mill finish aluminium Gutter (600 mm over all girth) DSR (12.66.6) 32 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR (13.4.2) 33 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) DSR (13.5.1) 34 Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement- Ordinary cement finish using ordinary cement.DSR (13.19.1) 35 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre.DSR (13.41.1) 36 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)DSR (13.46.1) 37 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactureDSR (13.62.1) 38 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR (13.80) 39 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.- Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)DSR (15.2.1) 40 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.DSR (15.3) 41 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar DSR (15.7.4) 42 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DSR (15.60) 43 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. DSR (16.44) 44 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. DSR (10.18) 45 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR (18.48) 46 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(NSI), Ref. CSI No. (28.38) SOR 23-24 47 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group CDSR (1.10.3) (Electrical) 48 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wireDSR (1.14.4) (Electrical) 49 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole DSR (2.10.1) (Electrical) 50 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps.DSR (2.12.2) (Electrical) 51 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door.DSR (2.4.1) (Electrical) 52 Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.DSR (17.1.1) (Electrical) 53 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required .DSR (17.1.2) (Electrical) 54 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required .DSR (17.1.3) (Electrical) 55 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required .DSR (17.1.5) (Electrical) 56 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. DSR (17.1.6) (Electrical) 57 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.6 Zone. DSR (17.1.9.2) (Electrical) 58 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation / communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 setDSR (17.1.11) (Electrical) 59 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. DSR (17.3.3) (Electrical) 60 (A) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)(B). Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.(C). Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.(D). M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(E). Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head DSR (18.3.3) (Electrical) 61 (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(B). Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.(D) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head DSR (18.4.2) (Electrical) 62 Providing laying, testing & commissioning of 150 mm. Dia C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required DSR (18.6.2) (Electrical) 63 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100mm dia DSR (18.14.5) (Electrical) 64 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 125mm dia DSR (18.14.6) (Electrical) 65 Attending Beldar ServicesDSR Code 0114 + 10% CP charge) 66 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. DSR (17.5.1) (Electrical) 67 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. DSR (17.5.2) (Electrical) 68 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.Speaker cable Single pair, 2-core, 1.5 sqmm. DSR (17.5.3.1) (Electrical) 69 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.Speaker cable Two pair, 2-core, 1.5 sqmm. DSR (17.5.3.2) (Electrical) 70 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. DSR (17.5.4) (Electrical) 71 (A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.(D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 56 m Head. DSR (18.1.6) (Electrical) 72 (A) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)(B) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(C) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(D) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads.2280 lpm at 56 m Head. DSR (18.2.6) (Electrical) 73 INCOMING250A, 50kA 4 Pole MCCB, lcs=100% lcu rating Digital Voltmeter 0-500V with selector switch, Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED typeRYB phase indicating lamps, ON, OFF,trip indicating lampsSet of Copper Bus Bar 300A OUTGOING-( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump-125 A, 50kA TPN MCCB, lcs=100% lcu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventer complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFFoperation.Jockey Pump-63 A, 50kA TPN MCCB, lcs=100% lcu, with suitable HP fully automatic Star/Delta starter with overloadprotection,current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch forlocal/remote; auto/manual/OFFoperation.Diesel Engine Control-Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication. Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter,and 0-20 A DC Ammeter. All standard relays and accessories for automatic operation of diesel engineSystem Controller-Designing, Supply, Installation, Testing and comm1ss1oning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication,complete as per specificationDSR (18.5.1) (Electrical) 74 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 200 mm. dia (wall thickness = 6.3 mm). DSR (18.6.1) (Electrical) 75 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 25 mm Dia. DSR (18.7.1) (Electrical) 76 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 32mm Dia. DSR (18.7.2) (Electrical) 77 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 40mm Dia. DSR (18.7.3) (Electrical) 78 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 50mm Dia. DSR (18.7.4) (Electrical) 79 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 65mm Dia.(DSR 18.7.5) (Electrical) 80 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 80mm Dia.(DSR 18.7.6) (Electrical) 81 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 100mm Dia.(DSR 18.7.7) (Electrical) 82 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For 150mm Dia. (DSR 18.7.8) (Electrical) 83 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as requ ired :Single headed Stainless steel (DSR 18.9.2) (Electrical) 84 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel (DSR 18.10.2) (Electrical) 85 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :For 80 mm dia (DSR 18.11.4 ) (Electrical) 86 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :For 100 mm dia (DSR 18.11.5) (Electrical) 87 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :For 150 mm dia (DSR 18.11.6) (Electrical) 88 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : For 80mm dia(DSR 18.12.4) (Eletrical) 89 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : For 100mm dia(DSR 18.12.5) (Electrical) 90 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : For 150mm dia(DSR 18.12.6) (Electrical) 91 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required (DSR 18.13) (Electrical) 92 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) (DSR 18.16.2) (Electrical) 93 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a). 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585.(b). 20 mm nominal internal dia gun metal globe valve & nozzle.(c). Drum and brackets for fixing the equipmets on wall.(d). Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. For 30 m (DSR 18.17.1) (Electrical) 94 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:Stainless Steel (Grade 304) (DSR 18.18.2)(Electrical) 95 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe (DSR 18.19.1) (Electrical) 96 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. ( DSR 18.20) (Electrical) 97 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :For Pendent Sprinkler .(DSR 18.21.1) (Electrical) 98 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :For Upright Sprinkler .(DSR 18.21.2) (Electrical) 99 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :For Horizontal side wall sprinkler .(DSR 18.21.3(Electrical) 100 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :For Concealed sprinkler .(DSR 18.21.4) (Electrical) 101 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (DSR 18.22) (Electrical) 102 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia DSR (23.1.1.1) 103 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia DSR (23.2.1.1) 104 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge- 200 mm nominal size dia DSR (23.3.3) 105 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia DSR (23.4.3) 106 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. DSR (23.8) 107 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. DSR (23.12) 108 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm dia DSR (23.14.3) 109 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia DSR (23.15.3) 110 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore DSR (18.12.8) 111 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore DSR (18.12.6) 112 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore DSR (18.17.4) 113 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover DSR (10.6.1) 114 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. g) three phase 10 HP outlet 80 mm dia. or more, Head 63/31, Discharge 20000/50000 LPH (NSI), Ref. CSI No. (19.32g) SOR 23-24 115 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work. (NSI), Ref. CSI No. (19.34) SOR 23-24 116 Supply and installation of 5H.P. Kirloskar or equivalent make single stage, horizontal, self priming,three phase dewatering pumpset of specification Head 14/16 M, Discharge 13.6/10 LPS, solid handle size 15.5 mm, suction 80 mm, delivery 80 mm, RPM 1500 including cost of 80 mm dia G.I. pipe for suction (3M) and delivery (4.5 M). (NSI), Ref. CSI No. (19.29) SOR 23-24 117 Supply and wiring of submain with two number 10 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25mm dia heavy guage rigid steel conduit on surface, with one number 10 SWG copper earth continuity wire etc. complete in all respect. (NSI), Ref. UPPWD (Electrical) (213B) 118 As in item no. 213 (B) but in 25 mm dia heavy duty (2mm thick ) PVC conduit with one number 6 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. (NSI), Ref. UPPWD (Electrical) (213C) 119 Supply and wiring of submain with two number in 32 mm dia heavy duty (2mm thick ) PVC conduit with one number 10 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.. (NSI), Ref. UPPWD (Electrical) (214C) 120 S&F of 100 A. 415 V Metal clad TPN CFS complete with HRC fuse etc. on angle iron frame complete in all respect. (NSI), Ref. UPPWD (Electrical) (353) CAT-B 121 S&F of 200 A. 415 V Metal clad TPN CFS complete with HRC fuse etc. on angle iron frame complete in all respect. (NSI), Ref. UPPWD (Electrical) (354) CAT-B 122 S&F of 200 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (NSI), Ref. UPPWD (Electrical) (379) 123 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT-AAA (NSI), Ref. UPPWD No. 1423 124 Supply and stacking pee gravelproperly at levelled ground for measurement as directed by Engineer I/C, including all labour, T&P required for proper completion of work. (NSI), Ref. CSI No. (19.25) SOR 23-24 125 Cartage of ballast,Kankar,Coal grit or sand etc. including loadingand unloading but excluding stacking at pucca roads.For 1st km.(NSI), Ref. CSI No. (3.01a) SOR 23-24 126 Providing all materials and labour & carrying out water proffing treatment of internal surface (positive surface) of under ground water storage tank of RCC with following process : (a) drilling 10 mm dia and 100 mm deep holes in wall surface with 04 holes per sqm (b) insurting PVC nozzles in each hole (c) injecting water profing material (s) with pressure in each hole with prescribed pressure (d) completing with required layers i.e fibre mess, Pidigrout10M 710 of Dr. Fixit, 113 Fastflex of Dr. Fixit , Pidicrete URP 301 of Dr. Fixit, using cement and course sand etc as per prescribed procedure.(NSI) Ref. (Rate already sanction by Agr. 58/2022-23) 127 Supply, installation, testing and commissioning of 80 mm dia strainer cum Foot valve along with all accessorieswith all labour and material cost etc.(NSI) Ref. (Rate already sanction by Agr. 58/2022-23) 128 Supply, laying, testing and commissioning of heavy duty cable ( aluminium conductor PVC insulated armoured served shethed cable 1100Volts grade at adeopth of 750 mm below GL over a cushion of 75 mm. thick sand all around and protected with burnt bricks on side and top. On surface the cable run shall be fixed on MS clamp etc of suitable size or as directed by tge engineer-incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamp etc. B8including necessary support clamp, connection legs complete in all respect. 50 Sqmm (3-1/2 core).(NSI), Ref. UPPWD No. 501 (I)(Electrical) 129 Supply, installation, testing and commissioning of Electronic Hooter with Flasher, 24 volt, DC operatable, made out of M.S. sheet heavy duty duly powder coated with epoxy powder coating, plastic body 500 mtrs. audible rangewith built in transformer etc.“AGNI” make.(NSI) Ref. (Rate already sanction by Agr. 58/2022-23 130 Supply of Installation of 63 KVA koel kirloskar diesel generator , 3 Phase Power solutions Kakinada. Product Specifications: Phase- 3- Phase, Engine Make- Kirloskar, Model Number KG1-62.5AS, Genset Brand- Koel, Power(KVA)-63 KVA, Prequency-50Hz, Fuel Consumption (at 100% Load)- 16.2, Output Voltage (V) - 230 V, Noise level-75, Engine Model- HA694TCI G1, No. of Culinder-4, Product Description: Koel iGreen offerings- AMF as standard, KOEL remote Monitoring, Silencer Inside canopy, Aesthetically enhanced genset, QR Code enabled genset, Multi-colour Status indicato.(NSI) 131 Supply and fixing of fire extinguisher, ABC Type 9.00 kg. capacity (ISI Marked IS: 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials of work. (U.P.P. W.D. Electrical Schedule 2018- 1131B). 132 Supply and fixing of C02 type fire extinguisher 6.5 kg. capacity (ISI Marked IS: 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. (U.P.P. W.D. Electrical Schedule 2018-1132A) 133 Hiring charge of Crane with operater and diesel for Shifting DG set and big size transformer on site work as per direction E/I.. (NSI) 134 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All outgoing switches of 315 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. (a) Outgoing (a) 100 Amp. TNP-3 Nos (ii) Cat. B. Cubicle Type (NSI), Ref. UPPWD No. 803 (a-ii) (Electrical) 135 (b) Outgoing (b) 100 Amp. TNP-2 Nos & 63 Amp TPN-2 Nos (ii) Cat. B. Cubicle Type. Ref. UPPWD No. 803 (b-ii) (Electrical) 136 (c) Outgoing (c) 100 Amp. TNP-1 No & 63 Amp TPN-3 Nos (ii) Cat. B. Cubicle Type Ref. UPPWD No. 803 (c-ii) (Electrical) 137 (d) Outgoing (d) 63 Amp. TNP-5 Nos (ii) Cat. B. Cubicle Type. Ref. UPPWD No. 803 (d-ii) (Electrical) 138 (e) Outgoing (e) 200 Amp. TNP-1 No & 32 Amp. TPN-1 No (ii) Cat. B. Cubicle Type. Ref. UPPWD No. 803 (e-ii) (Electrical)

Key Value

Document Fees
INR 5900 /-
EMD
INR 125000.0 /-
Tender Value
INR 1.24 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail