| 1 | Supplying,Replacement,Testing&Commissioningof faultyinvertercompressorwithnewoneoffollowing capacity inverter type scroll compressor in existing VRV/VRF system ofvoltas make including connection withsuitablesizeofsuctionofdischargecopperpipe, brazing the all joints and removing of leakages, vaccumizingthesystem,presuretestingwithnitrogen gas of the system (for 24 hrs) etc, connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.12 HP Outdoor compressor inverter type |
| 2 | Supplying,Replacement,Testing&Commissioningof faultyinvertercompressorwithnewoneoffollowing capacity inverter type scroll compressor in existing VRV/VRF system ofvoltas make including connection withsuitablesizeofsuctionofdischargecopperpipe, brazing the all joints and removing of leakages, vaccumizingthesystem,presuretestingwithnitrogen gas of the system (for 24 hrs) etc, connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.10HP Outdoor compressor inverter type |
| 3 | Supplying,ReplacementTesting&Commissioningof faulty Inverter PCB with new one of following capacity inverter type PCB in existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.12 HP Outdoor inverter PCB |
| 4 | Supplying,ReplacementTesting&Commissioningof faulty Inverter PCB with new one of following capacity inverter type PCB in existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.10 HP Outdoor inverter PCB |
| 5 | Supplying,ReplacementTesting&Commissioningof faulty Inverter PCB with new one of following capacity inverter type PCB in existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.12 HP Outdoor inverter PCB |
| 6 | Supplying,ReplacementTesting&Commissioningof faulty Inverter PCB with new one of following capacity inverter type PCB in existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.10 HP Outdoor Fan PCB |
| 7 | Supplying,Replacement,Testing&Commissioningof faulty Display PCB with new one of following capacity OutdoorDisplayPCBinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.12 HP Outdoor Display PCB |
| 8 | Supplying,Replacement,Testing&Commissioningof faulty Display PCB with new one of following capacity OutdoorDisplayPCBinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.10 HP Outdoor Display PCB |
| 9 | Supplying,Replacement,Testing&Commissioningof faultyTransistormodulewithnewoneoffollowing capacity outdoor Transistor module in existing VRV/VRFsystemofvoltasmakeincludingchecking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required.12 HP Outdoor Transistor module |
| 10 | Supplying,Replacement,Testing&Commissioningof faultyTransistormodulewithnewoneoffollowing capacity outdoor Transistor module in existing VRV/VRFsystemofvoltasmakeincludingchecking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required.10 HP Outdoor Transistor module |
| 11 | Supplying,Replacement,Testing&Commissioningof faulty Diode Module with new one of following capacity outdoordiodemoduleinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwith thimbles,cleaning etc. complete as required. 12 HP Outdoor Diode module |
| 12 | Supplying,Replacement,Testing&Commissioningof faulty Diode Module with new one of following capacity outdoordiodemoduleinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required. 10 HP Outdoor Diode module |
| 13 | Supplying,Replacement,Testing& Commissioningof faultyCementResistor withnewoneoffollowing capacity Outdoor Cement Resistor in existing VRV/VRF systemofvoltasmake includingcheckingallpartsof indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required.12 HP Outdoor Cement Resistor |
| 14 | Supplying,Replacement,Testing& Commissioningof faultyCementResistor withnewoneoffollowing capacity Outdoor Cement Resistor in existing VRV/VRF systemofvoltasmake includingcheckingallpartsof indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required.10 HP Outdoor Cement Resistor |
| 15 | Supplying,Replacement,Testing&Commissioningof faulty harness with new one of following capacity outdoor harness in existing VRV/VRF system of voltas makeincludingcheckingallpartsofindoor/outdoor units are properly connected etc. connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.12/10 HP Outdoor harness |
| 16 | Supplying,Replacement,Testing&Commissioningof faulty Compressor contractor Relay 3 Pole with new one offollowingcapacitycompressorcontractorrelayin existingVRV/VRFsystemofvoltasmakeincluding checkingallpartsofindoor/outdoorunits are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required.12/10 HP Outdoor Compressor contractor Relay 3 Pole |
| 17 | Supplying,Replacement,Testing&Commissioningof faultyDischargeSensor withnewoneof following capacity outdoor Discharge Sensor in existing VRV/VRF systemofvoltasmake includingcheckingallpartsof indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required.12/10 HP Outdoor DischargeSensor |
| 18 | Servicing,RepairingoffollowingVRFOutdoorunit installed at various location including cleaning of coolingcoil compressor, blower,fan &greasing as whererequiredandreplacementof burnedwired& repairing of Communication Fault etc. complete as required.12/10 HP Servicing of VRF Outdoor unit |
| 19 | Supplying,Replacement,Testing&Commissioningof faultyOutdoor Fan Motorwithnewoneoffollowingcapacity outdoor Outdoor Fan Motorin existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.12 HP Outdoor Fan Motor |
| 20 | Supplying,Replacement,Testing&Commissioningof faultyOutdoor Fan Motorwithnewoneoffollowingcapacity outdoor Outdoor Fan Motorin existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required. 10 HP Outdoor Fan Motor |
| 21 | Supplying,Replacement,Testing&Commissioningof faultyMainPCBwithnewoneoffollowingcapacity Indoor main PCB in existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.8 HP Indoor Main PCB |
| 22 | Supplying,Replacement,Testing&Commissioningof faultyMainPCBwithnewoneoffollowingcapacity Indoor main PCB in existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.5 HP Indoor Main PCB |
| 23 | Supplying,Replacement,Testing&Commissioningof faultyMainPCBwithnewoneoffollowingcapacity Indoor main PCB in existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required.3.5 HP Indoor Main PCB |
| 24 | Supplying,Replacement,Testing&Commissioningof faultyFanPCBwithnewoneoffollowingcapacity Indoor Fan PCB in existing VRV/VRF system of voltas makeincludingcheckingallpartsofindoor/outdoor units are properly connected etc. connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required.8 HP Indoor Fan PCB |
| 25 | Supplying,Replacement,Testing&Commissioningof faultyFanPCBwithnewoneoffollowingcapacity Indoor Fan PCB in existing VRV/VRF system of voltas makeincludingcheckingallpartsofindoor/outdoor units are properly connected etc. connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required.5 HP Indoor Fan PCB |
| 26 | Supplying,Replacement,Testing&Commissioningof faultyFanPCBwithnewoneoffollowingcapacity Indoor Fan PCB in existing VRV/VRF system of voltas makeincludingcheckingallpartsofindoor/outdoor units are properly connected etc. connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required.3.5 HP Indoor Fan PCB |
| 27 | Supplying,Replacement,Testing&Commissioningof faulty Display PCB with new one of following capacity IndoorDisplayPCBinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required.8 HP Indoor Display PCB |
| 28 | Supplying,Replacement,Testing&Commissioningof faulty Display PCB with new one of following capacity IndoorDisplayPCBinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required.5 HP Indoor Display PCB |
| 29 | Supplying,Replacement,Testing&Commissioningof faultyDrainPumpwithnewoneoffollowingcapacity IndoorDrainPumpinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required. 5/3.5 HP Indoor Drain Pump |
| 30 | Supplying,Replacement,Testing&Commissioningof faulty Fluid Sensor with new one of following capacity IndoorFluidSensorinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required. 5/3.5 HP Indoor Fluid Sensor |
| 31 | Supplying,Replacement,Testing&Commissioningof faultyGasSensorwithnewoneoffollowingcapacity IndoorGasSensorinexistingVRV/VRFsystemof voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required. 5/3.5 HP Indoor Gas Sensor |
| 32 | Supplying,Replacement,Testing&Commissioningof faulty Suction Sensor with new one of following capacityIndoorSuctionSensorinexistingVRV/VRF systemofvoltasmake includingcheckingallpartsof indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 5/3.5 HP Indoor SuctionSensor |
| 33 | Supplying,Replacement,Testing&Commissioningof faultyDischargeSensor withnewoneof following capacity Indoor Discharge Sensor in existing VRV/VRF systemofvoltasmake includingcheckingallpartsof indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required.5/3.5 HP Indoor DischargeSensor |
| 34 | Supplying&Chargingoffreshrefrigerant(wherever required) R-410 A in existingoutdoor unit VRV/VRF & Non VRF system after detecting and removing the leakage, pressure testing with nitrogen, vaccumising the system and charging the fresh refrigerant testing & commissioning etc. as required. |
| 35 | Servicing, Repairing of following VRF Indoor unit installed at various location including cleaning of coolingcoilcompressors,blower,fan&greasingas whererequiredandreplacementof burnedwired& repairing of Communication Fault etc. complete as required. 8/5/3.5/2/1.5 TR Servicing of VRF Indoor unit |
| 36 | SupplyingandLayingof2x1.5multi-corePVC insulated,PVCsheathedunarmoredBareroundcopper conductor, control/ communication cablein the existing cable tray/conduit with suitable calim /saddens including testing commission etc. as required. 2x1.5 sq.mm. multi-core control cable |
| 37 | Supplying,Replacement,Testing&Commissioningof faultyIndoor Fan Motorwithnewoneoffollowingcapacity outdoor indoor Fan Motorin existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required. 8 HP Indoor Fan Motor |
| 38 | Supplying,Replacement,Testing&Commissioningof faultyIndoor Fan Motorwithnewoneoffollowingcapacity outdoor indoor Fan Motorin existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required. 5 HP Indoor Fan Motor |
| 39 | Supplying,Replacement,Testing&Commissioningof faultyIndoor Fan Motorwithnewoneoffollowingcapacity outdoor indoor Fan Motorin existing VRV/VRF system of voltasmakeincludingcheckingallpartsofindoor/ outdoorunitsareproperlyconnectedetc.connections, interconnectionalltheelectricalwiringwiththimbles, cleaning etc. complete as required. 3.5 HP Indoor Fan Motor |
| 40 | Supplying,Replacement,Testing&Commissioningof complete out door panelwithnewoneoffollowing capacityin existing VRV/VRF system ofvoltas make including all type of PCB, Sensors, Connection Cable&connection withsuitablesizeofsuctionofdischargecopperpipe, brazing the all joints and removing of leakages, vaccumizingthesystem,presuretestingwithnitrogen gas of the system (for 24 hrs) etc, connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required. 12 HP Outdoor Complete Out Door Panel |
| 41 | Supplying,Replacement,Testing&Commissioningof complete out door panelwithnewoneoffollowing capacityin existing VRV/VRF system ofvoltas make including all type of PCB, Sensors, Connection Cable&connection withsuitablesizeofsuctionofdischargecopperpipe, brazing the all joints and removing of leakages, vaccumizingthesystem,presuretestingwithnitrogen gas of the system (for 24 hrs) etc, connections, interconnectionalltheelectricalwiringwiththimbles,cleaning etc. complete as required. 10 HP Outdoor Complete Out Door Panel |